HomeMy WebLinkAboutWQ0003720_Compliance Evaluation Inspection_20230504ROY COOPER
Governor
EMABETH S. BISER
Secretary
RICHARD E. ROGERS, X
Director
Ronnie F. and Marshia G. High
1046 King Drive
Butner, N.C. 27509
NORTH CAROLINA
Envfronmentat Quality
May 10, 2023
Subject: Compliance Evaluation Inspection
Single Family Wastewater Irrigation System
Non -Discharge Permit # WQ0003720
Facility: 1046 King Drive, SFR
Granville County
Dear Mr. and Mrs. High,
On May 4, 2023, Curtis Tyree from the Raleigh Regional Office visited your single-family
residence (SFR) wastewater treatment system to evaluate compliance with the subject Non -
Discharge Permit WQ0003720. Mr. High's assistance during the inspection was greatly
appreciated.
Our records indicate the treatment system consists of, a 1,200-gallon baffled septic tank; a 300
square foot surface sand filter; a flow splitter box; a recirculation tank with a %2 horsepower
recirculation pump; a tablet chlorinator; a 2,000-gallon storage/pump tank with a 16 gallon per
minute irrigation pump; a 0.I6 acre spray irrigation area; and all associated piping, valves,
controls, and appurtenances.
Non -Discharge Permit WQ0003720 authorizes the continued operation of up to 450 gallons per
day (gpd). The authorized irrigation is in accordance with the effluent limits and monitoring
requirements established within the non -discharge permit. The items below show what
conditions were noted at your facility:
Findings during the inspection were as follows:
1. Treatment system operation: The wastewater treatment system shall be
effectively maintained and operated at all times so there is no discharge to
�� North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609
"- + 4 919 791.4200
surface waters, nor any contravention of groundwater or surface water
standards. At the time of this inspection, the facility appears to be effectively
maintained. There were no signs of runoff or ponding in the irrigation field.
2. Pumping the septic tank: You are required to inspect the septic tank at least
once a year to determine if solids must be removed or if other maintenance is
necessary. Septic tanks should be pumped out every five years or when the
solids level is found to be more than 113 of the liquid depth in the septic tank
compartment, whichever is greater. A pumping company can check the status
periodically and determine when pumping is required. Mr. High showed me a
receipt where Scotty's Septic Tank Service pumped the septic tank out on 4-20-
2023.
3. Chlorine tablets in the chlorinator; The permittee is to inspect the tablet
chlorinator weekly to insure there is an adequate supply of chlorine tablets for
continuous and proper operation. At the time of the inspection, the chlorinator
had an adequate amount of chlorine tablets, and the correct type of chlorine
tablets were being used. Mr. High checks the system weekly.
4. Proper Operation and maintenance: The system shall be inspected monthly to
make certain of the proper operation of the spray heads, that the system is free
of leaks, that the vegetative growth allows a proper spray pattern, that the soil is
assimilating the disposed treated wastewater with no surface run off, and that
no objectional odors are being generated. Any visible signs of a malfunctioning
system shall be documented, and steps taken to correct the problem. On the day
of this inspection, the spray field appeared to be assimilating the waste and no
ponding/runoff was observed. The pumps and audible/visual alarms were working
properly, and the spray nozzles were spraying evenly. The system appeared to be
well maintained.
5. Field conditions: Public access to the irrigation sites and wastewater treatment
facilities shall be prohibited. Fencing shall be provided to prevent access to the
irrigation site. The irrigation field was well maintained, and no leaks or broken
lines were found. The fencing was more than adequate, and the system was in
good shape.
Non -discharge Permit WQ0003720 requires the permittee pay the annual fee within 30 days after
being billed by the division, and that the permittee must apply for a permit renewal 180 days
prior to the expiration of the permit. There are no overduefees at this time.
North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive l Raleigh, North Carolina 27e09
919.7914200
Please continue to periodically inspect the wastewater treatment facility in accordance with your
Operation and Maintenance agreement to ensure the treatment components are always
maintained and in good operating order. You are also reminded to maintain associated
maintenance records (permit required inspection log) onsite for a minimum of five years and
available for inspection.
If you have questions or comments about this inspection or the requirements to take corrective
action (if applicable), then please contact Curtis Tyree at 919-791-4239 or by email-
curtis.tyreea,ncdenngov .
Sincerely,
Vanessa E. Manuel, Assistant Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Attachment(s):
Cc: Laserfiche
North Carolina Department of Environmental Quality 1 Division of Water Resources
RaleCgh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609
919 791 4200
Compliance Inspection Report
Permit: WO0003720 Effective: 0510111 S Expiration: 04/30/23 Owner: Ronnie F Hlgh
SOC: Effective: Expiration: Facility: 1046 King Dr. SFR
County: Granville 1046 King Dr
Region: Raleigh
Butner NC 27509
Contact Person: Ronnie F High Title: Phone:
Directions to Facility:
System Classifications:
Primary ORC:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 05/04/2023
Primary Inspector: Curtis R Tyree
Secondary Inspector(s):
Certification: Phone:
Entry Time 01:20PM Exit Time: 01:45PM
Phone: 919-791-4239
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: Single -Family Residence Wastewater Irrigation
Facility Status: 0 Compliant ❑ Not Compliant
Question Areas:
Miscellaneous Questions Permit Status Septic Tank
Sand Filter/Treatment Pods Disinfection Tablets Pump Tank
Drip or Irrigation General
(See attachment summary)
Page 1 of 4
permit; WO0003720 Owner - Facility: Ronnie F High
Inspection Date: 05/04/2023 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
The system is well maintained. See inspection report
Page 2 of 4
Permit: W00003720 Owner - Facility: Ronnie F High
Inspection Date: 05/04/2023 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Permit Stratus Yes No NA NE
# Is the current resident in the home the Permittee? ❑ ❑ ❑
# If not, does the resident rent from the Permittee? ❑ ❑ M ❑
Change of Ownership form needed? (Mail the form with the inspection letter) ❑ ❑ M ❑
# Is there an inspection and maintenance agreement with a contractor? ❑ M 1111
If YES, who is the contractor (include contact info)?
Comment: Mr. High performs maintenance on the system.
Septic Tank Yes No NA NE
*** The septic tank and filters should be checked annually and pumped/cleaned as needed,
Is all wastewater from the home connected to the septic tank? M ❑ ❑ ❑
# Does the permittee/resident know where the septic tank is located? ❑ ❑ ❑
Has the septic tank been pumped in the last 5 years? ❑ ❑ ❑
If YES, describe if known and proof (include date pumped):
04-20-2023- Scotty's Septic Tank Service
# Does the septic tank have an EFFLUENT FILTER or SANITARY T? ❑ ❑ ❑
If FILTER, when was the filter cleaned and by who?
Comment:
Sand Filterrrreatment Pods Yes No NA NE
*** Accessible sand filter surfaces shall be rakedAeveled every 6 months and vegetative growth shall be
removed manually. ***
# Is system something other than a sand filter? ❑ ❑ ❑
# If YES, what kind? (examples - Peat, Textile or brand name - Advantex, etc.)
# Does the permittee know where the sandfilter is located? M ❑ ❑ ❑
Does the sandfilter require maintenance? 110 ❑ ❑
If maintenece is required, explain:
Comment: The sand filter appears to be working as designed.
Disinfection Tablets Yes No NA NE
*** Tablet chlorinator unit shall be checked weekly to ensure continuous and proper operation. *"
Does the permittee have the correct chlorine tablets? (If none, mark No) M ❑ ❑ ❑
# Does the Permittee know the location of the chlorinator? 0 ❑ ❑ ❑
Were chlorine tablets observed in the chlorinator? 0❑ ❑ ❑
Are tablets contacting water? (if possible, poke them to determine.) 0 ❑ ❑ ❑
Comment: The correct tablets are being used
Puma Tank Yes No NA NE
*' All pump and alarm sytems shall be inspected monthly. (Non -Discharge) "*
Page 3 of 4
Permit: W00003720 Owner - Facility: Ronnie F High
Inspection Date: 05/04/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Is the pump working? 0110 ❑
Is the audible and visual high water alarm operational? ❑ []
# Does the permittee know how to check the pump & high water alarm? M p ❑ ❑
# Last functional test:
Comment: The alarms were tested and are working properly
Drip or Irrination
Yes No NA NE
"' Irrigation sysetm shall be inspected monthly to ensure system is free of leaks and equipment is operating
as designed. "'
# Type of system (DRIP or IRRIGATION):
irrigation
# If IRRIGATION, number of sprinkler heads:
6
Are buffers and setbacks adequate?
Is the site free of ponding and runoff?
Does the application equipment appear to be working properly?
�]
Is there a minimum two wire fence surrounding the entire irrigation area?
Comment: The system is well kept
General
Yes No NA NE
# Are the treatment units locked and/or secured?
M []
# Has resident had any sewage problems?
If YES, explain:
Does the system match the permit description?
If NO, explain:
Is the system compliant?
0 11 ❑ El
Is the system failing? (If yes, take pictures if possible)
0 M ❑
If system is failing, describe any exposures to people/animals or environmental risks.
Comment: The system is working according to design
Page 4 of 4