Loading...
HomeMy WebLinkAboutWM0501549_Application_20230503 (2)NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. 1. Date: 5/2/2023 2. County: FOR OFFICE USE ONLY PERMIT NO. ISSUED DATE 3. What type of well are you applying for? (monitoring or recovery): monitoring 4. Applicant: Tony Southerland Telephone: 919-934-8939 Applicant's Mailing Address: 1105 Southerland Rd Clayton, NC 27527 Applicant's Email Address (if available): 5. Contact Person (if different than Applicant): Ryan Kerins Telephone: 919-563-9091 Contact Person's Mailing Address: 100 E. Ruffin St Mebane, NC 27302 Contact Person's Email Address (if available): rdkerins(@terraguestpc.com 6. Property Owner (if different than Applicant): Property Owner's Mailing Address: Property Owner's Email Address (if available): Telephone: 7. Property Physical Address (Including PIN Number) 4549 Wilsons Mills Rd PIN#169609-07-9370 City Smithfield County Johnston Zip Code 27577 8. Reason for Well(s): groundwater contamination (ex: non -discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) 9. Type of facility or site for which the well(s) is(are) needed: UST (ex: non -discharge facility, waste disposal site, landfill, UST, etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). NCDWM-UST Incident 29463 11. Type of contaminants being monitored or recovered: petroleum (ex: organics, nutrients, heavy metals, etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes, how many? 8 Existing Monitoring or Recovery Well Construction Permit No(s).: Unknown 13. Distance from proposed well(s) to nearest known waste or pollution source (in feet): 0-30' 14. Are there any water supply wells located less than 500 feet from the proposed well(s)? Yes If yes, give distance(s): 299 15. Well Contractor: Wes Sorrells Terraquest Environmental Certification No.: 3577 Well Contractor Address: 100 E Ruffin St Mebane, NC 27302 PROPOSED WELL CONSTRUCTION INFORMATION As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons C. Screen intervals g. Well head completion details d. Sand/gravel pack intervals Continued on Reverse PROPOSED WELL CONSTRUCTION INFORMATION (Continued) 2. Number of wells to be constructed in unconsolidated 5. How will the well(s) be secured? material: 3 Bolted manhole with locked well cap 3. Number of wells to be constructed in bedrock: 0 6. Estimated beginning construction date: 5/2023 4. Total Number of wells to be constructed: 3 7. Estimated construction completion date: 5/2023 (add answers from 2 and 3) ADDITIONAL INFORMATION 1. As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system. C. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. SIGNATURES The Applicant assumes total responsibility for ensuring that the well(s) will be located, constructed, maintained, and abandoned in accordance with 15A NCAC 02C. Signature of Applicant or *Agent Ryan Kerins Printed name of Applicant or *Agent Project Manger Title of Applicant or *Agent * If signing as Agent, attach authorization agreement stating that you have the authority to act as the Agent. If the property is owned by someone other than the Applicant, the property owner hereby consents to allow the Applicant to construct well(s) as outlined in this Well Construction Permit application and acknowledges that it shall be the responsibility of the Applicant to ensure that the well(s) will be located, constructed, maintained, and abandoned in accordance with 15A NCAC 02C. Signature of Property Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources' Regional Office: Asheville Regional Office Raleigh Regional Office Wilmington Regional Office 2090 U.S. Highway 70 3800 Barrett Drive 127 Cardinal Drive Extension Swannanoa, NC 28778 Raleigh, NC 27609 Wilmington, NC 28405 Phone: (828) 296-4500 Phone: (919) 791-4200 Phone: (910) 796-7215 Fax: (828) 299-7043 Fax: (919) 571-4718 Fax: (910) 350-2004 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9797 r rh* r a r p 1 4- 4A A' a n W in e E Dir ISM% Twrk A 4k*AU*"pA'l 1&0 ik tA 111 the **,#t 44 P ANA rN w,'7k' 44� f ,/ 0 0-olow- -AN1111111- �6._ Surface Water 3 Surface water 1 ESTIMATED EXTENT OF GCL VIOLATIONS � �F% /�MW2 Fiberglass lines G ,- r / Dispensers Surface Water 2 W8 \ MW. Old product ei C product lines /<,{J T MW333* \ / J.D.'s STO MW7 — .ESTIMATED EXTENT OF 2L STANDARD V-1 ATI- ��'ST4 VORY 14 t r' 40 _4 z r r 4 �MW4 Slgn UP s� Dispensers 0 \ T2 T3 ASTI z _ r � LEGEND vi `1' N r. J Type II Groundwater Monitoring Well N ' Type III Groundwater Monitoring Well 0 P _j o • Surface Water Sample Location Uj i Proposed well location o O i o o Accelerated site char. soil sample LL1_ o wD:f o There are no known Y O to 0O } w1 m m ' sources of groundwater 3: � 00 q I contamination within z Z to 500' of the wells z 00 proposed following G.S. W U fn 1­_r g �_ Z m r 143-215. 1OB(5) C/) o o o Z ILL] ur) U w 2i ¢ C) \ W n o rM 0 Z g M II a O Of O_ LLJ = ~ o Z O fn Z O F_ U O Q N n Table 1 SITE HISTORY (UST/AST SYSTEM INFORMATION) Date: V7109 Incident Name _J.D'sCountryStore Incident No-29463 FacilltyIDNo:0-013454 Capacity UST Product (Gallons) Date Installed Date Closed Release Discovered _ T1 Gasoline 6,000 1215/71 7i9107 Yes Ttb Gasoline 3,000 1215/71 7/9/07 Yes T2 Gasoline 12,000 1/1/02 NIA No T3 Gasoline 8,000 1/1/02 NIA No T4 Diesel 5,000 1/1/02 N/A No T5 Gasoline 6,000 7112107 NIA NIA T51b Diesel 4,000 7/12/07 N/A NIA Capacity AST Product (Gallons) Date Installed Date Closed Release Discovered AST1 Kerosene 550 6101 in -use No - AST2 Off -Road Diesel 550 6101 in -use No AST3 Off -Road Diesel 1,000 6101 in -use No AST4 Kerosene 550 1/81 6/01 No Notes_ 1. Information obtained from the INC UST Database Records, onsite observations, and responsible party. 2. No release from the other USTs orASTs has been discovered. 3. Installation and closure dates for the ASTs are aooroximate. The ASTs are owned by Stancil Oil Com Danv_ GRAPHIC SCALE 0' 15' 30' 60' 1 " = 30' FIGURE 2 - TYPICAL TYPE II MONITORING WELL DETAIL 8" MANHOLE COVER rel LOCKING CAP GENERAL INFORMATION / CEMENT GROUT Groundwater monitoring wells are simple 2" diameter wells used to monitor groundwater quality. They are constructed using Schedule 40 PVC piping and screen as shown in the diagram to the left. Upon completion, an 8" round 8' / manhole cover is installed over the well for protection. In the event that the well is 9' BENTONITE SEAL installed in an area where there exists the possibility that it could be damaged such as an 10' - TOP OF SCREEN agricultural field, an aboveground or stickup _ manhole will be used. After the manhole is set, — a small concrete pad is poured around the —_ manhole. Both the manhole and pad are flush — with the ground surface, except as noted, and — will not interfere with driving, mowing, foot —_ traffic, etc. Type II monitoring wells are used — for sampling groundwater from shallow, — unconfined aquifers. They are used to determine the horizontal extent of contamination. — Well Driller: —_ Terraquest Environmental Consultants, P.C. - - Jonathan R. Grubbs #3001 - GRAVEL PACK 30' - BOTTOM OF SCREEN BOTTOM OF BORING 6„ TEP4MIUest ENVIRONMENTAL CONSULTANTS, P.C.