HomeMy WebLinkAboutSW6221102_Design Calculations (Rip Rap)_20230510Project Name Riprap Dissipator #1 Date
Ashley Heights Oct, 2022
DD Project No.
Location D&L Engineering, PLLC DD221 l
Hoke County, North Carolina 150 S. Page Street Calculated By
Southern Pines, NC 28387 JLH
(910) 684-8646 Checked By
JLH
(STORM DESIGN: 10 Year
BACKGROUND: Use the E&S Control Planning & Design Manual, Section 8.06.
REFERENCE: (NCDEHNR 1993)
Step 1. Minimum Tailwater Condition
Step 2.
D-o =
24 in.
D-o =
2.00 ft,
0-25 =
20.69 cfs
d-50 =
0.4 ft.
L-a =
14 ft.
Step 3.
3'D-o =
6.00 ft.
W =
16.00 ft.
Step 4.
d-max
0.60 ft.
d-max
7 in.
Step 5. Thickness = 0.90 ft.
Thickness = 11 in.
DESIGN DIMENSIONS:
Pipe diameter in inches
Pipe diameter in feet
Pipe outlet (from drainage calculations)
from Figure 8.06 a
from Figure 8.06 a
3 times the outlet pipe diameter
Pipe diameter + Apron length
Maximum Stone Diameter (1.5'd-50) in inches
Maximum Slone Diameter (1.5'd-50) in feet
Min. Apron Thickness With Filter Fabric (1.5"d-max) in feet
Min. Apron Thickness With Filter Fabric (1.5'd-max) in inches
Apron Dimensions
Riprap
Length
Width
3"D-o Thick
1
Class
14
16
6 24in.
1
TERMINOLOGY: Q10 = 10-Year Design Storm, Peak Discharge, (cfs)
D-o = Pipe Diameter, (in. & ft.)
d-50 = Mean Stone Diameter of Rip -Rap, (ft.)
L-a = Length of Rip -Rap Apron, (ft.)
3`D-o = Width of Rip -Rap Apron @ Pipe Outlet, (ft.)
W = Width of Rip -Rap Apron @ End of Apron, (ft.)
d-max = Maximum Stone Diameter of Rip -Rap, (ft. & in.)
Thickness = Thickness of Rip -Rap Apron With Filter Fabric, (ft. &in.)
Project Name Riprap Dissipator #2 Date
Ashley Heights Oct, 2022
DD Project No,
Location D&L Engineering, PLLC DD2211
Hoke County, North Carolina 150 S. Page Street Calculated By
Southern Pines, NC 28387 JLH
(910) 684-8646 Checked By
JLH
ISTORM DESIGN: 10 Year
(BACKGROUND: Use the E&S Control Planning & Design Manual, Section 8.06.
(REFERENCE: (NCOEHNR. 1993)
Step 1. Minimum Tailwater Condition
Step 2. D-o = 48 in. Pipe diameter in inches
D-o = 4.00 ft. Pipe diameter in feet
0-25 = 92.63 cfs Pipe outlet (from drainage calculations)
d-50 = 0.9 ft.
L-a = 26 ft.
from Figure 8.06 a
from Figure 8,06 a
Step 3. 3*D-o = 12.00 ft. 3 times the outlet pipe diameter
W = 30.00 ft. Pipe diameter + Apron length
Step 4. d-max 1.35 ft. Maximum Slone Diameter (1.5*d-50) in inches
d-max 16 in. Maximum Stone Diameter (1.5*d-50) in feet
Step 5. Thickness = 2.03 ft.
Thickness = 24 in.
IDESIGN DIMENSIONS:
Min. Apron Thickness With Filter Fabric (1.5*d-max) in feet
Min. Apron Thickness With Filter Fabric (1.5*d-max) in inches
Apron Dimensions Riprap
Length Width 3*D-o Thick Class
26 30 12 36in. 2
TERMINOLOGY: Q10 = 10-Year Design Storm, Peak Discharge, (cfs)
D-o = Pipe Diameter, (in. & ft.)
d-50 = Mean Stone Diameter of Rip -Rap, (ft.)
L-a = Length of Rip -Rap Apron, (ft.)
3*D-o = Width of Rip -Rap Apron @ Pipe Outlet, (ft.)
W = Width of Rip -Rap Apron @ End of Apron, (ft.)
d-max = Maximum Stone Diameter of Rip -Rap, (ft. & in.)
Thickness = Thickness of Rip -Rap Apron With Filter Fabric, (ft. &in.)
(Project Name
Ashley Heights
Riprap Dissipator #3
Location D&L Engineering, PLLC
Hoke Counh,, forth Carolina 150 S. Page street
Southern Pines, NC 28387
(910) 684-8646
STORM DESIGN: 10 Year
BACKGROUND: Use the E&S Control Planning & Design Manual, Section 8.06
(REFERENCE: (NCDEHNR, 1993)
Step 1. Minimum Tailwater Condition
Step 2. D-o = 30 in. Pipe diameter in inches
D-o = 2.50 ft. Pipe diameter in feet
Q-25 = 27.12 cfs Pipe outlet (from drainage calculations)
d-50 = 0.5 ft
L-a = 16 ft,
from Figure 8.06 a
from Figure 8.06 a
Step 3. 3*D-o = 7.50 ft. 3 times the outlet pipe diameter
W = 18.50 ft. Pipe diameter + Apron length
Step 4, d-max 0,75 ft. Maximum Stone Diameter (1.5`d-50) in inches
d-max 9 in. Maximum Stone Diameter (1.5*d-50) in feet
Step 5. Thickness = 1 13 ft.
Thickness = 14 in.
DESIGN DIMENSIONS:
Date
Oct, 2022
DID Project No.
DD2211
Calculated By
JLH
Checked By
JLH
Min. Apron Thickness With Filter Fabric (1.5*d-max) in feet
Min. Apron Thickness With Filter Fabric (1.5*d-max) in inches
Apron Dimensions Riprap
Length Width 3-D-o Thick Class
16 19 8 24in. 1
:TERMINOLOGY: Q10 = 10-Year Design Storm, Peak Discharge, (cfs)
D-o = Pipe Diameter, (in. & ft.)
d-50 = Mean Stone Diameter of Rip -Rap, (ft.)
L-a = Length of Rip -Rap Apron, (ft.)
3*D-o = Width of Rip -Rap Apron @ Pipe Outlet, (ft.)
W = Width of Rip -Rap Apron @ End of Apron, (ft.)
d-max = Maximum Stone Diameter of Rip -Rap, (ft. & in.)
Thickness = Thickness of Rip -Rap Apron With Filter Fabric. (ft. &in.)
Project Name Riprap Dissipator #4 Date
Ashley Heights Oct, 2022
DO Project No.
Location D&L Engineering, PLLC DD2211
Hoke County, North Carolina 150 S. Page Street Calculated By
Southern Pines, NC 28387 .ILH
(910) 684-8646 Checked By
JLH
STORM DESIGN: 10 Year
BACKGROUND: Use the E&S Control Planning & Design Manual, Section 8.06.
REFERENCE: (NCDEHNR, 1993)
Step 1. Minimum Tailwater Condition
Step 2.
D-o =
24 in.
D-o =
2.00 ft.
0-25 =
12.73 cfs
d-50 =
0.4 ft.
L-a =
14 ft.
Step 3.
3'D-o =
6.00 ft.
W =
16.00 ft.
Step 4.
d-max
0.60 ft.
d-max
7 in.
Step 5. Thickness = 0.90 ft.
Thickness = 11 in.
DESIGN DIMENSIONS:
Pipe diameter in inches
Pipe diameter in feet
Pipe outlet (from drainage calculations)
from Figure 8.06 a
from Figure 8.06 a
3 times the outlet pipe diameter
Pipe diameter + Apron length
Maximum Stone Diameter (1.5*d-50) in inches
Maximum Stone Diameter (1.5*d-50) in feet
Min. Apron Thickness With Filter Fabric (1.5"d-rnax) in feet
Min. Apron Thickness With Filter Fabric (1.5"d-max) in inches
Apron Dimensions
Rlprap
Class
Length
Width
3-D-o
Thick
14
16
6
241n.
1
NOLOGY: Q10 = 10-Year Design Storm, Peak Discharge, (cfs)
D-o = Pipe Diameter, (in. & ft.)
d-50 = Mean Stone Diameter of Rip -Rap, (ft.)
L-a = Length of Rip -Rap Apron, (ft.)
3*D-o = Width of Rip -Rap Apron @ Pipe Outlet, (ft.)
W = Width of Rip -Rap Apron @ End of Apron, (ft.)
d-max = Maximum Stone Diameter of Rip -Rap, (ft. & in.)
Thickness = Thickness of Rip -Rap Apron With Filter Fabric, (ft. &in.)
Project Name Riprap Dissipator #5 Date
Ashley Heights May, 2022
DID Project No.
Location D&L Engineering, PLLC Do22 t I
Hoke County, North Carolina 150 S. Page Street Calculated By
Southern Pines, NC 28387 JLH
(910) 684-8646 Checked By
JLH
STORM DESIGN: 10 Year
BACKGROUND: Use the E&S Control Planning & Design Manual, Section 8.06.
REFERENCE: (NCDEHNR, 1993)
Step 1. Minimum Tailwater Condition
Step 2. D-o =
24 in.
Pipe diameter in inches
D-o =
2.00 ft.
Pipe diameter in feet
Q-25 =
3,43 cfs
Pipe outlet (from drainage calculations)
d-50 =
0.4 ft.
from Figure 8.06 a
L-a =
12 ft.
from Figure 8.06 a
Step 3. 3*D-o =
6,00 ft.
3 times the outlet pipe diameter
W =
14.00 ft.
Pipe diameter + Apron length
Step 4. d-max
0.60 ft.
Maximum Stone Diameter (1.5*d-50) in inches
d-max
7 in.
Maximum Stone Diameter (1.5*d-50) in feet
Step 5. Thickness = 0.90 ft.
Thickness = 11 in.
DESIGN DIMENSIONS:
Min. Apron Thickness With Filler Fabric (1.5*d-max) in feet
Min, Apron Thickness With Filter Fabric (1.5*d-max) in inches
Apron Dimensions
Riprap
Length
Width
3*D-o
Thick
Class
12
14
1 6
241n.
1
TERMINOLOGY: Q10 = 10-Year Design Storm. Peak Discharge, (cfs)
D-o = Pipe Diameter, (in. & ft.)
d-50 = Mean Stone Diameter of Rip -Rap, (ft.)
L-a = Length of Rip -Rap Apron, (ft.)
3*D-o = Width of Rip -Rap Apron @ Pipe Outlet, (ft.)
W = Width of Rip -Rap Apron @ End of Apron, (ft.)
d-max = Maximum Stone Diameter of Rip -Rap, (ft. & in.)
Thickness = Thickness of Rip -Rap Apron With Filter Fabric, (ft. &in.)
Project Name Riprap Dissipator #6 Date
Ashley Heights May, 2022
DD Project No.
Location D&L Engineering, PLLC DD2211
Hoke County, North Carolina 150 S. Page Street Calculated By
Southern Pines, NC 28387 J[fH
(910)684-8646 Checked By
JLH
STORM DESIGN: 10 Year
BACKGROUND: Use the E&S Control Planning & Design Manual. Section 8.06.
REFERENCE: (NCDEHNR, 1993)
Step 1. Minimum Tailwater Condition
Step 2.
D-o =
24 in.
Pipe diameter in inches
D-o =
2.00 ft.
Pipe diameter in feet
Q-25 =
21.83 cfs
Pipe outlet (from drainage calculations)
d-50 =
0.4 ft.
from Figure 8.06 a
L-a =
14 ft.
from Figure 8.06 a
Step 3.
3*D-o =
6.00 ft.
3 times the outlet pipe diameter
W =
16.00 ft.
Pipe diameter + Apron length
Step 4,
d-max
0.60 ft.
Maximum Stone Diameter (1.5*d-50) in inches
d-max
7 in.
Maximum Stone Diameter (1.5*d-50) in feet
Step 5.
Thickness =
0.90 ft.
Min. Apron Thickness With Filter Fabric (1.5*d-max) in feet
Thickness =
11 in.
Min. Apron Thickness With Filter Fabric (1.5*d-max) in inches
IDESIGN DIMENSIONS:
Apron Dimensions
Riprap
Glass
Len th
Width
3-D-o
Thick
14
16
6
24in.
1
TERMINOLOGY: Q10 = 10-Year Design Storm, Peak Discharge, (cfs)
D-o = Pipe Diameter, (in. & ft.)
d-50 = Mean Stone Diameter of Rip -Rap, (ft.)
L-a = Length of Rip -Rap Apron, (ft.)
3*D-o = Width of Rip -Rap Apron @ Pipe Outlet, (ft.)
W = Width of Rip -Rap Apron @ End of Apron, (ft.)
d-max = Maximum Stone Diameter of Rip -Rap, (ft. & in.)
Thickness = Thickness of Rip -Rap Apron With Filter Fabric, (ft. &in.)