Loading...
HomeMy WebLinkAbout820439_Other_20230504 Mix rphy-Brown . 4 zn 23 Ar Irrigation Equipment Field Calibration Form 4 Location(s): eA `7 Date of Field Calibration: 923 O -3 (min/dd/yy) Flow Meter Serial Number: P Equipment Number: Measured ring size: inches Is ring size wit in 0.01" of original manufactured size? Yes or No. If not replace ring. Pressure Gauge Readings At Pump: Z O psi At Traveler: _ psi (if applicable) At Sprinkler/Gun: _ psi Expected Flow Rate(from manufacturers chart): _�j GPM Measure Flow Rate(from flow meter): 14 2 GPM Flow rate variance greater than 10%? Yes No Expected Wetted Diameter(from the wettable'acres determination): ft. Measured Wetted Diameter: cgs!r / ft. Wetted diameter variance greater than 15%? Yes No If"Yes"to either variance,then contact a technical specialist or irrigation dealer for assistance, enter work order number: and/or explain findings: Calibrator: (Signature) Retention Period: 3 years Revision: 4/1/06 RECEIVE® Murphy-Brown_ � ���� 0 4 2o23 t'DEQ/bVVR Irrigation Equipment Field Calibration Form 'ntral Office Location(s): �,y..! �' �� --• N Date of Field Calibration: (mm/dd/yy) Flow Meter Serial Number: V*j Equipment Number: -�7.0227- pe'r-1 A 1.1 Measured ring size: 4Q S /, inches Is ring size wit 0.01" of original manufactured size? Yes or No. If not replace ring. Pressure Gauge Readings At Pump: psi At Traveler: & psi (if applicable) At Sprinkler/Gun: Sz psi Expected Flow Rate(from manufacturers chart): 16_� _ _ - GPM Measure Flow Rate(from flow meter): _-/-��GPM Flow rate variance greater than 10%? Yes No Expected Wetted Diameter(from the wettable acres determination): ? j} ft. Measured Wetted Diameter: I fI. Wetted diameter variance greater than 15%? Yes No If"Yes"to either variance, then contact a technical specialist or irrigation dealer for assistance, enter work order number: and/or explain findings: Calibrator: v71 (Signa ure) Retention Period: 3 years Revision: 4/I/06 FCF �qV 0 4 Z023 Murphy-Brown � CL °a Qo � Irrigation Equipment Field Calibration Form Location(s): A�Xal $iZ - 0� Date of Field Calibration: (rnin/ddlyh— Flow Meter Serial Number: Equipment Number: Measured ring size: , G inches Is ring size wi,', n 0.01"of original manufactured size? Yes or No. If not replace ring_ Pressure Gauge Readings At Pump: 1- /114 psi At Traveler: —1 k psi (if applicable) At Sprinkler/Gun: LO'S Expected Flow Rate(from manufacturers chart): f/ GPM Measure Flow Rate(from flow meter): //0 GPM Flow rate variance greater than 10%? Yes No l---- Expected Wetted Diameter(from the wettable acres determination): - ft. Measured Wetted Diameter: Z� ft. Wetted diameter variance greater than 15%? Yes No If"Yes"to either variance, then contact a technical specialist or irrigation dealer for assistance, enter work order number, and/or explain findings: Calibrator: '1 ;, z, Retention Period: 3 years Revision: 4/1/06