HomeMy WebLinkAboutSW6230102_Supplement-EZ Form_20230504SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1 Project Name
Tranquil Meadows
2 Project Area ac
21.83
3 Coastal Wetland Area ac
0
4
Surface Water Area ac
0
5
is this project H h or Low Dens'
High
6
Does this project use an off -site SCM?
No
COMPLIANCE WITH 02H .1008I4
7
JWkIth of vegetated setbacks provided feet
30
8
Will the vegetated setback remain vegetated?
N/A
9
If SUA is proposed in the setback, does it meet NCAC 02H.1003 4 Gd ?
N/A
10
Is streambank stabilization proposed on this project?
No
NUMBER AND TYPE OF SCMs:
11
Infiltration System
12
Bioretention Cell
13
Wet Pond
1
14
Stormwater Wetland
15
Permeable Pavement
16
Sand Filter
17
Rainwater Harvesting RWH
18
Green Roof
19
Level Spreader -Filter Strip LS-F5
20
Disconnected Impervious Surface DI5
21
Treatment Swale
22
Dry Pond
StormFilter
23
24
Silva Cell
25
Bayfifter
26
Filterra
FORMS LOADED
DESIGNER CERTIFICATION
27
Name and Title:
Street address:
Jeffrey A. Nobles, PE
28Organization:
LeM King & Associates, RLS, PA
29
1333 Morganton Road, Suite 201
30
City, State, Zip:
Fayetteville, NC 28305
31
Phone number(s):
1 Email:
910-483-4300
jnobles@lkanda.com
32
Certification Statement:
i certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the
information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; anc teat the engineering plans,
specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here.
`'�\A1111111l1'd
CA
= SEAL
31459
Ne
� c
Date
•3.23
DRAINAGE AREAS
1
IIs this a high density roect?
Yes
2
If so, number of drainage areas/SCMs
1
3
Does this project have low density areas?
No
4
If so, number of low density drainage areas
0
5
Is all/part of this project subject to previous rule
versions?
No
FORMS LOADED
DRAINAGE AREA INFORMATION
Entire It9
4
Type of SCM
Wet Pond
5
Total drainage area (sq ft
951040
908838
6
Onsite drainage area (sq ft
0
7
Offsite drainage area (sq ft
8
Total BUA in project ft
372337 sf
372337 sf
9
New BUA on subdivided lots (subject to permitting)
1 (sq ft
240000 sf
240000 sf
10permitting)
New BUA not on subdivided lots (subject to
s
sf
sf
11
Offsite BUA (sq ft
sf
sf
12
Breakdown of new BUA not on subdivided lots:
Parking (sq ft
5800 sf
5800 sf
Sidewalk (sq ft
- Roofs ft
Roadway sq ft)
Future (sq T
Other, please specify in the comment box
below (sq ft
New infiltrating permeable pavement on
subdivided lots (sq ft
30661 sf
30661 sf
sf
sf
95876 sf
95876 sf
sf
sf
sf
sf
13
sf
sf
New infiltrating permeable pavement not on
subdivided lots s ft
sf
sf
P1614
15
Existing BUA that will remain (not subject to
permitting)s ft
sf
sf
Existing BUA that is already permitted (sq ft
sf
sf
17 Existing BUA that will be removed s ft
sf
sf
41 %
1.0 in
38802 cf
Simple Method
18 Percent BUA 39%
19 Design storm {inches) 1.0 in
20 Design volume of SCIv1 (cu ft
21 CaiCUlatlon method for design volume Simple Method
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
22 draina a area(s):
WET POND
1
Drainage area number
1
2
Minimum required treatment volume cu ft
38802 cf
GENERAL
MDC FROM OZH .1
3
Is the SCM sized to treat the SW from all surfaces at build -out?
Yes
4
Is the SCM located away from contaminated soils?
Yes
5
What are the side slopes of the SCM H: ?
3:1
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes?
Are the inlets, outlets, and receiving stream protected from erosion
-year storm)?
Is there an overflow or bypass for inflow volume in excess of the
design volume?
No
7
Yes
8
Yes
9
What is the method for dewatering the SCM for maintenance?
Pum ferred
10
tf applicable, will the SCM be cleaned out after construction?
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
12
Does the drainage easement comply with General MDC 9 ?
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC 10)?
Is there an O&M Agreement that complies with General MDC (11)?
Is there an O&M Plan that complies with General MDC (12)?
Does the SCM follow the device specific MDC?
N/A
14
Yes
15
Yes
16
Yes
17
Was the SCM designed by an NC licensedprofessional?
Yes
FROM
18
Sizing method used
SA1DA
19
Has a stage/storage table been provided in the calculations?
Elevation of the excavated main pool depth (bottom of sediment
removal) (fmsl
Elevation of the main pool bottom (top of sediment removal) (fmsl)
Yes
20
217.00
21
218.00
22
Elevation of the bottom of the vegetated shelf (tmsl)
221.50
23
Elevation of the parmanentpool fmsl
222.00
24
Elevation top of the vegetated shelf fmsl
222.50
25
_of -the
Elevation of the temporary of fmsl
223.70
26
Surface area of the main permanent pool (square feet
19464
27
Volume of the main permanent pool cubic feet
61450 cf
28
Averse depth of the main pool feet
3.63 ft
29
Average depth equation used
Equation 3
30
If using equation 3, main pool 22rimeter feet
557.0 ft
31
If using equation 3, width of submerged veg. shelf (feet)
5.0 ft
32
Volume of the foreba cubic feet
10267 of
33
Is this 15-20% of the volume in the mainpool?
Yes
34 1
Clean -out deM for foreba inches
48 in
35
Design volume of SCM cu ft
45744 of
36
Is the outlet an orifice or a weir?
Crifice
37
If orifice, orifice diameter inches
If weir, weir height inches
If weir, weir length (inches)
Drawdown time for the temporary pool (dc_: =,:
Are the inlet(s) and outlet located in a manner that avoids short-
circuiting?
Are berms or baffles provided to improve the flow pa --h?
Depth of fo ay at entrance inches
3 in
38
39
40
2,97
Yes
41
42
No
43
60 in
44
Depth of forebay at exit inches
54 in
45
Does water flow out of the forebay in a non -erosive manner?
Yes
46
Width of the vegetated shelf (feet)
Slope of vegetated shelf (H:V)
Does the orifice drawdown from below the top surface of the
permanent pooI?
Does the pond minimize impacts to the receiving channel from the 1-
r, 24-hr storm?
loft
47
10:1
48
Yes
49
Yes
50
Are fountains proposed? (If Y, please provide documentation that
MDC 9 is met.
No
51
Is a trash rack or other device provided to protect the outlet system?
Yes
52
Are the dam and embankment planted in non -clumping turf grass?
Yes
53
Species of turf that will be used on the dam and embankment
Bermuda
54
Hasa planting plan been provided for the vegetated shelf?
Yes
ADDITIONAL
INFORMATION
55 Please use this space to provide any additional information about the
wet pond(s):
Wet Pond 1 10:10 AM 5/3/2023