Loading...
HomeMy WebLinkAboutNC0065587_Compliance Evaluation Inspection_20150520 • AVA NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Donald R. van der Vaart Governor Secretary May 20, 2015 Aqua North Carolina Inc. Attn: Thomas J. Roberts, President and CEO 202 Mackenan Drive RECEIVED/DENR/DWR Cary, NC 27511 Subject: Compliance Evaluation Inspection MAY 2 2 2015 Permittee: Aqua NC Inc. Water Quality Facility: Frye Bridge Wastewater Treatment Plant Permitting Section NPDES Permit#: NC0065587 Forsyth County Dear Mr. Roberts: Ron Boone of the Winston-Salem Regional Office of the NC Division of Water Resources (DWR or the Division) conducted a compliance evaluation inspection (CEI) of the Frye Bridge Wastewater Treatment Plant (WWTP) on May 19, 2015. The assistance and cooperation of Sam Pegram, Operator in Responsible Charge, was greatly appreciated. An inspection checklist is attached for your records and inspection findings are summarized below. General Information The Frye Bridge Wastewater Treatment Plant is located in Winston-Salem, Forsyth County, NC at approximate coordinates 35.988913°N, 80.353408°W. The permit authorizes Aqua to operate this 0.027 MGD WWTP, which consists of a bar screen, aeration basin, clarifier, aerated sludge holding tank, tablet chlorinator, chlorine contact chamber, tablet dechlorinator, and post aeration. The permit authorizes Aqua to discharge the treated effluent from the WWTP via outfall 001 to an unnamed tributary to Muddy Creek. Muddy Creek is currently classified as Class C waters and is located in the Yadkin Pee-Dee river basin. Site Review Mr. Pegram has done an excellent job operating and maintaining the plant. The plant was clean and well maintained, except for a significant amount of corrosion in the plant. This was noted in the last inspection as well and nothing has been done to address it yet. The plant is operated quite well and sludge/solids are being effectively managed. Odors at the plant were minimal. Documentation Review All documentation was reviewed and no discrepancies were found. Mr. Pegram has done an excellent job documenting the operation and maintenance of the plant as required by the permit. This includes 450 West Hanes Mill Road,Suite#300,Winston-Salem,North Carolina 27105 Phone:336-776-9800 l Internet:www.ncdenr,gov An Equal Opportunity\Affirmative Action Employer—Made in part by recycled paper • f operations and visitation logs, discharge monitoring reports, laboratory and field laboratory records, chains of custody, etc. There were no other concerns noted during the inspection. If you have any questions regarding the inspection or this letter, please call Mr. Boone or me at (336) 771-5000. Thank you for your cooperation in this matter. Sincerely, W. Corey Basinger Regional Supervisor Water Quality Regional Operations Division of Water Resources Attachments: 1. BIMS Inspection Report CC: WSRO - SWP Central Files NPDES Unit United States Environmental Protection Agency Form Approved. EPA Washington,D.C.20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A:National Data System Coding(i.e.,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 11 2 IS I 3 I NC0065587 I11 12 1 15/05/19 117 18 I,I 19 LI I 201 I 211 11111111111 1 11 11 1 11 111I 1 1 11111 11111 /111 1 1 r6 Inspection Work Days Facility Self-Monitoring Evaluation Rating Bi QA Reserved 671 1 70 U 71 LI I 72 I ti I 731 1 174 751 1 1 I 1 1 1 180 Section B:Facility Data LJ Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10:00AM 15/05/19 14/06/01 Frye Bridge WWTP — Exit Time/Date Permit Expiration Date NCSR 2998 Clemmons NC 27012 11:00AM 15/05/19 19/05/31 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Ill Samuel E.Pegram/ORC/704-489-9404/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Tim Wadde11,202 Mackenan Cir Cary NC 27511//919-467-8712/ No Section C:Areas Evaluated During Inspection(Check only those areas evaluated) • Permit • Flow Measurement • Operations&Maintenance • Records/Reports ▪ Self-Monitoring Program • Sludge Handling Disposal • Facility Site Review • Effluent/Receiving Waters • Laboratory Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Ron Boone WSRO WQ//336-776-9690/ G153;L 5/2_Z Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date e '.�-t- w.;Sty?.o : .40 4747 14 it EPA Form 3560-3(Rev 9-94)Previous editions are obsolete. Page# 1 NPDES yr/mo/day Inspection Type 1 NC00e5557 111 121 15/05/19 117 18 IA Section D:Summary of Finding/Comments(Attach additional sheets of narrative and dieddists as necessary) Please refer to the attached inspection summary letter. Page* 2 Permit NC0065587 Owner-Facility: Frye Bridge WWTP inspection Date 05/19/2015 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 0 • 0 application? Is the facility as described in the permit? • 0 0 0 #Are there any special conditions for the permit? 0 • 0 0 Is access to the plant site restricted to the general public? • 0 0 0 Is the inspector granted access to all areas for inspection? • 0 0 0 Comment: None Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? • 0 0 0 Is all required information readily available,complete and current? • ❑ 0 0 Are all records maintained for 3 years(lab. reg.required 5 years)? • 0 0 0 Are analytical results consistent with data reported on DMRs? • 0 0 0 Is the chain-of-custody complete? • 0 0 0 Dates,times and location of sampling • Name of individual performing the sampling • Results of analysis and calibration U Dates of analysis • Name of person performing analyses • Transported COCs Are DMRs complete:do they include all permit parameters? • 0 0 0 Has the facility submitted its annual compliance report to users and DWQ? 0 0 • 0 (If the facility is=or>5 MGD permitted flow)Do they operate 24/7 with a certified operator 0 • 0 0 on each shift? Is the ORC visitation log available and current? • 0 0 0 Is the ORC certified at grade equal to or higher than the facility classification? • 0 0 0 Is the backup operator certified at one grade less or greater than the facility classification? • 0 0 0 Is a copy of the current NPDES permit available on site? • 0 0 0 Facility has copy of previous year's Annual Report on file for review? 0 0 • 0 Comment: None Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? • 0 0 0 Are all other parameters(excluding field parameters)performed by a certified lab? • 0 0 0 Page* 3 Permit: NC0065587 Owner•Facility: NYE)Bridge WWrP Inspection Date: 05/19/2015 Inspection Type: Compliance Evaluation Laboratory Yes No NA NE #Is the facility using a contract lab? • 0 0 0 #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees 0 0 0 • Celsius)? Incubator(Fecal Coliform)set to 44.5 degrees Celsius+/-0.2 degrees? 0 0 0 • Incubator(BOD)set to 20.0 degrees Celsius+/-1.0 degrees? 0 0 0 • Comment: None Effluent Sampling Yes No NA NE Is composite sampling flow proportional? • 0 0 0 Is sample collected below all treatment units? • 0 0 0 Is proper volume collected? • 0 0 0 Is the tubing clean? • 0 0 0 #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees • 0 0 0 Celsius)? Is the facility sampling performed as required by the permit(frequency,sampling type • 0 0 0 representative)? Comment: None Upstream/Downstream Semolina Yes No NA NE Is the facility sampling performed as required by the permit(frequency,sampling type,and • 0 0 0 sampling location)? Comment: None Bar Screens Yes No NA NE Type of bar screen a.Manual • b.Mechanical 0 Are the bars adequately screening debris? • 0 0 0 Is the screen free of excessive debris? • 0 0 0 Is disposal of screening in compliance? • 0 0 0 Is the unit in good condition? • 0 0 0 Comment: None Aeration Basins Yes No NA NE Page# 4 Permit NC0065587 Owner-Facility: Frye Bridge VVVVTP Inspection Date: 05/19/2015 inspection Type: Compliance Evaluation Aeration Basins Yes No NA NE Mode of operation Ext.Air Type of aeration system Diffused Is the basin free of dead spots? • 0 0 0 Are surface aerators and mixers operational? 0 0 • 0 Are the diffusers operational? • 0 0 0 Is the foam the proper color for the treatment process? • 0 0 0 Does the foam cover less than 25%of the basin's surface? • 0 0 0 Is the DO level acceptable? 0 0 0 U Is the DO level acceptable?(1.0 to 3.0 mg/I) 0 0 0 U Comment: None Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? • 0 0 0 Is the site free of excessive buildup of solids in center well of circular clarifier? 0 0 • 0 Are weirs level? • 0 0 0 Is the site free of weir blockage? • 0 0 0 Is the site free of evidence of short-circuiting? • 0 0 0 Is scum removal adequate? • 0 0 0 Is the site free of excessive floating sludge? • 0 0 0 Is the drive unit operational? 0 0 • 0 Is the return rate acceptable(low turbulence)? • 0 0 0 Is the overflow clear of excessive solids/pin floc? U 0 0 0 Is the sludge blanket level acceptable?(Approximately 1/4 of the sidewall depth) 0 0 0 • Comment: None Pumps-RAS-WAS Yes No NA NE Are pumps in place? • 0 0 0 Are pumps operational? • 0 0 0 Are there adequate spare parts and supplies on site? • 0 0 0 Comment: None Flow Measurement-Effluent Yes No NA NE #Is flow meter used for reporting? • 0 0 0 Page# 5 Permit NC0065587 Owner-Facility: Frye Bridge WWTP Inspection Date: 05/19/2015 Inspection Type: Compliance Evaluation Flow Measurement-Effluent Yes No NA NE Is flow meter calibrated annually? • 0 0 0 Is the flow meter operational? • 0 0 0 (If units are separated)Does the chart recorder match the flow meter? • 0 0 0 Comment: None Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? • 0 0 0 Are the tablets the proper size and type? • 0 0 0 Number of tubes in use? 4 Is the level of chlorine residual acceptable? 0 0 0 • Is the contact chamber free of growth,or sludge buildup? • 0 0 0 Is there chlorine residual prior to de-chlorination? 0 0 0 • Comment: None De-chlorination Yes No NA NE Type of system? Tablet Is the feed ratio proportional to chlorine amount(1 to 1)? • 0 0 0 Is storage appropriate for cylinders? 0 0 • 0 #Is de-chlorination substance stored away from chlorine containers? • 0 0 0 Are the tablets the proper size and type? • 0 0 0 Comment: None Are tablet de-chlorinators operational? • 0 0 0 Number of tubes in use? 4 Comment: None Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? • 0 0 0 Are the receiving water free of foam other than trace amounts and other debris? • 0 0 0 If effluent (diffuser pipes are required) are they operating properly? 0 0 U 0 Comment: None • Aerobic Diaester Yes No NA NE Is the capacity adequate? • 0 0 0 Page# 6 Permit NC0065587 Owner-Facility: Frye Bridge WWTP Inspection Date: 05/19/2015 Inspection Type: Compliance Evaluation Aerobic Dioester Yes No NA NE Is the mixing adequate? • 0 0 0 Is the site free of excessive foaming in the tank? • 0 0 0 #Is the odor acceptable? • 0 0 0 #Is tankage available for properly waste sludge? • 0 0 0 Comment: None Operations& Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • 0 0 0 Does the facility analyze process control parameters,for ex: MLSS, MCRT,Settleable • 0 0 0 Solids, pH, DO, Sludge Judge,and other that are applicable? Comment: None Page# 7