Loading...
HomeMy WebLinkAboutMecklenburg_Well Abandonment_20230505 (9) WELL ABANDONMENT RECORD For Internal Use ONLY: 1.Well Contractor Information: WELL ABANDONMENT DETAILS Brian James Bellis I 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only I GW_130 is needed. Indicate TOTAL NUMBER of wells abandoned: NCWC 3510-A NC Well Contractor Certification Number 7b.Approximate volume of water remaining in well(s): (gal.) WithersRavenel, Inc. FOR WATER SUPPLY WELLS ONLY: ;7 q ,' Company Name , '' 7c.Type of disinfectant used: 2.Well Construction Permit#: Not Applicable 2�23 List all applicable if-ell construction Permits(i.e.UK',C'ouniv,Stale, Variance,etc.)ifknoirn 7d.Amount of disinfectant used: It)+�i�inrci,-„) �f, -, fir 3.Well use(check well use): Water Supply Well: 7e.Sealing materials used(check all that apply): ❑Agricultural ❑Municipal/Public ❑Neat Cement Grout A Bentonite Chips or Pellets ❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑ Dry Clay ❑Industrial/Corn mere ial ❑Residential Water Supply(shared) a Concrete Grout ❑ Drill Cuttings ❑Irrigation ❑ Specialty Grout ❑ Gravel Non-Water Supply Well: ❑ Bentonite Slurry ❑ Other(explain under 7g) ❑Monitoring eRecovery Injection Well: 7f.For each material selected above,provide amount of materials used: []Aquifer Recharge ❑Groundwater Remediation Bentonite Chips —30 pounds ❑Aquifer Storage and Recovery ❑Salinity Barrier ❑Aquifer Test - ❑StormwaterDrainage Concrete Grout —20 pounds ❑Experimental Technology ❑Subsidence Control 7g•Provide a brief description of the abandonment procedure: ❑Geothermal(Closed Loop) ❑Tracer ❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) Soil vapor extraction (SVE)well was screened above the water table and was used to recover VOC vapors a.Date well(s)abandoned: April 27, 2023 from subsurface for soil remediation. Well was sa.well location: filled with bentonite chips and capped with concrete. Trex Properties, LLC NCD 049 773 245 Facility/Owner Name Facility ID9(ifapplicable) S.Certification: 3114 & 3124 Cullman Avenue, Charlotte, 28206 May 1, 2023 Physical Address,City,and Zip Signature ofCertifted Well Contractor or Well Owner Date Mecklenburg 08303112 By signing this form, I hereby certify that the well(s) was (were) abandoned in County Parcel Identification No.(PIN) accordance with 15A NCAC 02C.0100 or 2C.0200 Well Construction Standards gib.Latitude and longitude in degrees/minutes/seconds or decimal degrees: and that a copy of this record has beery provided to the ivell owner. (ifwell field,one lat/long is sufficient) 9.Site diagram or additional well details: 35.248949 N -80.809492 W You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS Alrach well cotisirnctioti record(s)ijar•ailable. For multiple it jection or non-tratersupply trolls ONLY frith the sane constructionlabandonment,you can submit one form. IOa. For All Wells: Submit this form within 30 days of completion of well 6a.Well ID#: SVE-20 abandonment to the following: Division of Water Resources,Information Processing Unit, 6b.Total well depth: 5.9 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617 10b.For Iniection Wells: In addition to sending the form to the address in 10a 6c.Borehole diameter: 10 (in.) above, also submit one copy of this form within 30 days of completion of well abandonment to the following: 6d.Water level below ground surface: Not Applicable(ft) Division of Water Resources,Underground Injection Control Program, 1636 Mail Service Center,Raleigh,NC 27699-1636 6c.Outer casing length(if known): (ft.) loc.For Water Suooly&Iniection Wells: In addition to sending the form to the address(es)above,also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where 6E Inner casing/tubing length(if known): (ft.) abandoned. 6g.Screen length(if known): 5.4 I I Fortn GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016