HomeMy WebLinkAboutMecklenburg_Well Abandonment_20230505 (18) WELL ABANDONMENT RECORD For Internal use ONLY:
II
1.Well Contractor information: WELL ABANDONMENT DETAILS
Brian James Bellis 7a.For Gcoprobe/DPT or Closed-Loop Geothermal Wells having the same
Well Contractor Narne(or well owner personally abandoning well on his'hei propem•) well construction/depth,only I GW-30 is needed. Indicate TOTAL NUMBER of
NCWC 3510-A wells abandoned:
NC Well Conti-actor Certification Number 7b.Approximate volume of water relmaining in well(s): (gal.)
WithersRavenel, Inc. FOR WATER SUPPLY WELLS ONLi•:
Company Name 7c.Type of disinfectant used: t �'' E e
2.Well Construction Permit#: Not Applicable MAY p K 2023
List all applicable well construction permits(i.e.U1C,C'ountp,State, I arimu•e,etc.)tl'bnown
7d.Amount of disinfectant used:
3.Well use(check well use):
Water Supply Well: 7e.Sealing materials used(check tdl that apply): CAMI ZOG
❑Agricultural ❑Municipal/Public ❑ Neat Cement Grout A Bentonite Chips or Pellets
❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑ Dry Clay
❑Industrial/Commercial ❑Residential Water Supply(shared) a Concrete Grout ❑ Drill Cuttings
❑Irri ation ❑ Specialty Grout ❑ Gravel
Non-Water Supply Well: ❑ Bentonite Slurry ❑ Other(explain under 7g)
❑Monitoring IN Recovery
Injection Well: 7f.For each material selected above,provide amount of materials used:
❑Aquifer Recharge ❑Groundwater Remediation Bentonite Chips —25 pounds
❑Aquifer Storage and Recovery ❑Salinity Barrier
❑Aquifer Test ❑Stormwater Drainage Concrete Grout ^20 pounds
❑Experimental Technology ❑Subsidence Control 7g,Provide a brief description of the abandonment procedure:
[]Geothermal(Closed Loop) ❑Tracer Soil vapor extraction (SVE) well was screened above
❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g)
the water table and was used to recover VOC vapors
4.Date well(s)abandoned: April 27, 2023 from subsurface for soil remediation. Well was
5a.Well location: filled with bentonite chips and capped with concrete.
Trex Properties, LLC NCD 049 773 245
Facility/Owner Name Facility ID#(ifapplicable) S.Certification: /•'lam /J/l:"�
3114 & 3124 Cullman Avenue, Charlotte, 28206 1 we�f" May 1, 2023
Physical Address,City,and Zip Signature of Certified Well Contractor or Well Owner Date
Mecklenburg 08303112
By signing this form. /hereby certify that the wells) was (were) abandoned in
Comtry Parcel Identification No.(PiN) accordance with 15A NCAC 02C.0100 or 2C.0200 Well Construction Standards
56.Latitude and longitude in degrees/minutes/seconds or decimal degrees: and that a copy of this record has been provided to the well owner.
(ifwell field,one Iat/long is sufficient) 9.Site diagram or additional well details:
35.248949 N -80.809492 `� You may use the back of this page to provide additional well site details or well
abandonment details. You may also attach additional pages if necessary.
CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS
Aitaclr hell consiraction record(s)iJ'urailable. For multiple ihyection or non-waiersupply wells
ONLY with the same construcliotr/abattdonnrent,you can submit one form.
10a. For All Wells: Submit this form within 30 days of completion of well
6a.Well ID#: SVE-3 abandonment to the following:
Division of Water Resources,Information Processing Unit,
6b.Total well depth: 4•6 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617
10b.For Injection Wells: In addition to sending the form to the address in 10a
6c.Borehole diameter: 10 (in.) above, also submit one copy of this form within 30 days of completion of well
abandonment to the following:
6d.Water level below ground surface: Not Applicable(ft.) Division of Water Resources,Underground Injection Control Program,
1636 Mail Service Center,Raleigh,NC 27699-1636
6e.Outer casing length(if known): (ft.) 10c.For Water Supply&iniectioti Wells: In addition to sending the form to the
address(es)above,also submit one copy of this form within 30 days of completion
of well abandonment to the county health department of the county where
611 inner casing/tubing length(if known): (ft.) abandoned.
6g.Screen length(if known): 4.1 (ft.)
I