Loading...
HomeMy WebLinkAboutSW3170101_Stormwater Report_20230503St. Philips the Apostle: Education Center City of Statesville I Iredell County I North Carolina CALCULATIONS FOR: Built Upon Area PREPARED FOR: NCDEMLR Stormwater Program 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Submitted: Little Project Number March 23, 2023 112.5254.02 + d v`' 038668lvk + — q•.. . ••'�, .�f PREPARED BY: Little Diversified Architectural Consulting 615 South College Street, Suite 1600 Charlotte, North Carolina 28202 615 South College Street, Suite 1600, Charlotte, INC 28202 t 704.525.6350 w littleonline.com St. Philips the Apostle: Education Center Little Project Number 112.5254.02 TABLE OF CONTENTS Project Narrative & NCDEQ EZ Forms............................................................3 USGSTopo Map..................................................................................8 BuiltUpon Area Maps...........................................................................10 Current State Stormwater Permit SW3170101.................................................13 NOTE" The most recent version of these calculations shall supersede all others. 615 South College Street, Suite 1600, Charlotte, NC 28202 t 704.525.6350 w littleonline.com St. Philips the Apostle: Education Center Little Project Number 112.5254.02 PROJECT NARRATIVE PROJECT DESCRIPTION & I OCA TION MAP The proposed St. Philips the Apostle Education Center is located at 525 Harmony Drive in Statesville, North Carolina. The site consists of one parcel identified as Iredell County Property Identification Number 4744750333.000 totaling 4.991 acres. The project proposes the demolition and replacement of a portion of the existing church facility. The owner of the property is Catholic Diocese of Charlotte. Lav::e�ce CY L yple 9i N O n gfackgumflr a � �n HZE14 1 FT - "IM I I I wJ Figure 1. Location Map (Iredell County GIs, 2023). 615 South College Street, Suite 1600, Charlotte, INC 28202 t 704.525.6350 w littleonline.com 3 St. Philips the Apostle: Education Center Little Project Number 112.5254.02 EXISTING CONDITIONS The existing site contains a church & classroom building, a Parish Hall, and associated parking. The site has been developed since the late-1970's. The site is bounded by Interstate 77 to the east, Harmony Drive to the south, vacant residential property to the west, and residential properties to the north. Existing site grades generally range from an approximate elevation of 865 feet along the ridge line where the existing buildings are located, then down a steep wooded slope to the north and parking lot to the southwest. The parking lot discharges to a draw that runs south to north along the western property line. The property is in Flood Zone X. Please refer to FEMA Map Number 3710474400J. SU/L T-UPONAREA The existing church facility was issued a State Stormwater Permit in January 2017, prior to the construction of a parking lot on the parcel south of the proposed Education Center parcel. State and local jurisdictions were unable to provide the plans and calculations for this permit, however, the permit itself was provided and is included in this report. Per the approved permit, the site is low density. By maintaining the impervious area approved during development of the parking lot, the site will remain low density. The Existing BUA Map included with this report shows the existing conditions as what was approved under State Stormwater Permit SW3170101 (BUAEX = 99,606 sf). The Proposed BUA Map shows site improvements since that permit was issued (BUAPR = 97,448 sf). The overall BUA decreases in the proposed condition, however, future BUA is noted (BUAFUT = 2,158 sf) such that the Diocese has flexibility to install additional BUA up to the amount noted in the existing conditions map (99,606 sf). 615 South College Street, Suite 1600, Charlotte, INC 28202 t 704.525.6350 w littleonline.com 4 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name 2 Proiect Area (ac) 4 ISurface Water Area Does this Proiect use an off -site SCM? St. Philips the Apostle Education Center 4.991 N/A N/A Low No COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided feet N/A 8 Will the ve etated setback remain vegetated? N/A 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003 4 c-d ? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration S stem 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting RWH 18 Green Roof 19 Level Spreader -Filter Strip LS-FS 20 Disconnected Impervious Surface DIS 21 Treatment Swale 22 1 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Frank G. Miller, PE 28 Organization: Little Diversified Architectural Consulting 29 Street address: 615 South College Street, Suite 1600 30 City, State, Zip: Charlotte, NC 28202 31 Phone numbers : 704-561-8752 32 Email: frank.miller@littleonline.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer ;`lit t }tLl CAPOZ�t ;` ��� ►t AL 038685 �f'�+�+✓rllllll111t41 tp� t3 Signature of Designer 03/23/2023 Date DRAINAGE AREAS 1 Is this a hi h density project? No 2 If so, number of drainage areas/SCMs 0 3 Does this project have low density areas? Yes 4 If so, number of low density drainage areas 1 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site LID 1 4 Type of SCM n/a 5 Total drainage area (sq ft 217408 6 Onsite drainage area (sq ft 217408 7 Offsite drainage area (sq ft 0 8 Total BUA in project (sq ft -2158 sf 9 New BUA on subdivided lots (subject to ermitting) (sq ft n/a 10 New BUA not on subdivided lots (subject to ermittin sf n/a 11 Offsite BUA (sq ft sf 12 Breakdown of new BUA not on subdivided lots: Parking (sq ft Sidewalk (sq ft Roof (sq ft -2158 sf Roadway s ft - Future sq ft 2158 sf - Other, please specify in the comment box below (sq ft 13 New infiltrating permeable pavement on subdivided lots (sq ft sf 14 New infiltrating permeable pavement not on isubdivided lots (sq ft sf 15permitting) Existing BUA that will remain (not subject to s ft 97448 sf 16 Existing BUA that is already permitted (sq ft 99606 sf 17 Existing BUA that will be removed (sq ft sf 18 Percent BUA 0% 19 Design storm inches 20 Design volume of SCM cu ft 21 Calculation method for design volume ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): Existing BUA permitted as part of SW3170101. No increase in BUA proposed as part of this project. Future BUA noted so that total allowable BUA matches what was approved as part of SW3170101. LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H .1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per .1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances (H:V) 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 6 Are curb outlet swales proposed? No 7 1 Maximum longitudinal slope of curb outlet swale(s) (%) 8 Bottom width of curb outlet swale(s) (feet) 9 Maximum side slope of curb outlet swale(s) (H:V) 10 Minimum length of curb outlet swale(s) (feet) 11 Are treatment swales used instead of curb outlet swales? 12 Is stormwater released at the edge of the setback as dispersed flow? N/A 13 1 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 JAre variations to rule .1003 proposed? Yes ADDITIONAL INFORMATION 15 1 Please use this space to provide any additional information about this low density project: This project reduces the built -upon area from what was approved under SW3170101. While there are inlets and piping proposed in the courtyard, the outlet of that pipe system discharges into an existing parking lot where stormwater is captured in an existing curb inlet. This is the same as the existing conditions. Even with the proposed pipes, stormwater still exits the site via the existing piping from the parking lot curb inlet, thus meeting 15A NCAC 02H .1003(6)(a) for ".....equal or better stormwater control..." Roof leaders for the propsed building have been designed to match the existing roof leader drainage areas and outlet point, thus meeting 15A NCAC 02H .1003(6)(a) for ".....equal or better stormwater control..." St. Philips the Apostle: Education Center Little Project Number 112.5254.02 USGS TOPOGRAPHIC MAP 615 South College Street, Suite 1600, Charlotte, INC 28202 t 704.525.6350 w littleonline.com 63 [R64AAS' 1 _ r_p4tf{FR'pp 7 iNT RF NarrorraL W O &ROOKGRE Ta A 62 z 90 TA f�VAI~ p`t� r —x -- R C4iYSARKlRD OP 7-3 t; oaESY Y� t a 61 El 60 S'ITA rES v t 1 j, ° RApR f =a sRuvr Ra I � f � •� y� �� � �� _' 5$ aetriro t_ ` 70 C ' CRY pp sY�e p�{ SCALE 1:24 000 1 O's 0 MLOMfTERS 1 2 ■ NpRFH pLl NA 1000 504 0 METERS 1000 2940 1 0.5 0 1 MILES 10130 0 1000 20110 3000 4WD 5000 600a 7000 3000 4000 10000 QUAllPWiGLE iS CAI9k FEET 1 Central CONTOUR INTERVAL 10 FEET 1 2 3 2 Harmony NORTH AMERICAN VERTICAL VATUM OF 148 3 Calahaln 4 Statesville West This map was produced to conform with the 5 Cool Springs National Geospatial Program US Topo Product Standard, 2011. b Troutman A metadaLa file associated with this product is draft version 0.6.18 6 7 $ 7 Shepherds 8 Cleveland 9 ADJOINING QUADRANGLES St. Philips the Apostle: Education Center Little Project Number 112.5254.02 BUILT -UPON AREA MAPS 615 South College Street, Suite 1600, Charlotte, INC 28202 t 704.525.6350 w littleonline.com 10 rsOr 99 °r 0. g �q50' P65'$6� / PARCE �\ 4744750 z co N O O M N O N C N CCU G X w CL (6 Q r) L 0 U) U 0 U 2 0) c w U c L a] c W M c 0) a� 0 N L U w (D 0 Q Q T n U) N O LO N N 0 L M U 0 a) U) a� U O_ r) U_ 0 M UI 0 O U iD C E O U E / Gh°tfOtte ok ese �51 Ol) / / / 100 L �U O Camden Drive a L Camden Drive C NO RECORDED ROAD R/W WIDTH FOUND C 60' R/W WIDTH ILLUSTRATED a � E rt o = �Ln G s 7 0 EXISTING B UA: 99.606 SF oe 0000, GRAPHIC SCALE \ \ 40 0 20 40 80 160 11 1 11 = 40'-0" 615 South College 00 Charlotte, NC 28202 - www.littleonline.com This drawing and the design shown are the proper y of Little Diversified Architectural Consulting. The reproduction, copying or other use of this draining without their written consent is prohibited and any infringement will be subject to legal action. © Little 2023 P�GNITECTU� TECTU/�! O P C O > CERT. NO. o 50033 z z c ) �j • . /H CAVV�- c�RLOTTI \ G- License # F-0467 CA fS �f rfl = 038668 AP Construction Documents 13/23 0.R DATE PROJECT TEAM PRINCIPAL IN CHARGE David Powlen, PLA PROJECT MANAGER Casey Cline, PLA DESIGN TEAM PROJECT St. Philip the Apostle Education Center PROJECT 112.5254.02 SHEET TITLE Drainage Area Map: Existing Conditions SHEET NUMBER C402 J M O 0 0 M N O N C N L Cco G 0) n cU Q r) E L 0 ``_ VJ U 0 U 0) c w U c L (] W 0) .7 r) N L U w 0 Q Q Q L n U) N O NT LO N N 0 L M U 0 a) U) a� U O_ r) U_ O 5 M U I 0 O U U) C E O U E Jotr`e �2 p6 Pf ce 2�22q. 6��g� PfN. / G�QtWO_ f cese 5� e�5 ,56 ,1 00 i PARCEL ID#: I � 4744740895.000 0 12 0 ')ED BUA: ALLOWABLE BUA: 'ARCEL BUA ALLOWED: M [%I(1TC- 971448 SF 2,158 SF 997606 SF BUILT-UPON AREA RE -CALCULATED FOR PARCEL ID #4744750333.000 ONLY. NO IMPROVEMENTS PROPOSED ON PARCEL ID #4744740895.000, THEREFORE THAT PARCEL IS STILL IN COMPLIANCE WITH STATE STORMWATER PERMIT SW3170101. GRAPHIC SCALE 40 0 20 40 80 1" = 40'-011 W-111 615 South College Street, Suite .00 Charlotte, INC 28202 - www.littleonline.com This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. © Little 2023 P�,"ITECTI, `C ��N\TECTU�! P � O > CERT. NO. o 50033 z z CARD c�RLOTTE, NG. License # F-0467 ���.•' 5 C1AR�" t �}' ~ AL 038668 Construction Documents 13/23 0.R DATE PROJECT TEAM PRINCIPAL IN CHARGE David Powlen, PLA PROJECT MANAGER Casey Cline, PLA DESIGN TEAM PROJECT St. Philip the Apostle Education Center PROJECT 112.5254.02 SHEET TITLE Drainage Area Map: Proposed Conditions SHEET NUMBER C403 St. Philips the Apostle: Education Center Little Project Number 112.5254.02 CURRENT STATE STORMWATER PERMIT 615 South College Street, Suite 1600, Charlotte, NC 28202 t 704.525.6350 w littleonline.com 13 State Stormwater Permit Permit No.SW3170101 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT QUALITY STATE STORMWATER MANAGEMENT PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules and Regulations PERMISSION IS HEREBY GRANTED TO St. Phillip Catholic Church, Statesville, NC, Iredell County FOR THE construction, operation and maintenance of a low density development, in compliance with the provisions of 15A NCAC 2H .1017 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications, and other supporting data as attached and on file with and approved by the State and considered a part of this permit. The Permit shall be effective from the date of issuance until rescinded and shall be subject to the following specific conditions and limitations: I. DESIGN STANDARDS 1. The overall tract built -upon area percentage for the project must be maintained below 24%, as required by 15A NCAC 2H .1017 of the stormwater rules. 3. Approved plans and specifications for projects covered by this permit are incorporated by reference and are enforceable parts of the permit. 4. The only runoff conveyance systems allowed will be vegetated conveyances such as swales with minimum side slopes of 3:1 (H:V) as defined in the stormwater rules and approved by the Division. 5. No piping is allowed except that minimum amount necessary to direct runoff beneath an impervious surface such as a road or to provide access. 6. All roof drains must terminate at least 30 foot from the mean high water mark. 7. The built -upon areas associated with this project shall be located at least 30 feet landward of all perennial and intermittent streams. 8. All swales that discharge into a wetland shall do so at a non -erosive velocity for the 10 year storm. 9. Curb cuts must be provided where ribbon curbs and/or curb and gutter is provided. II. SCHEDULE OF COMPLIANCE 1. The permittee is responsible for verifying that the proposed built -upon area does not exceed the allowable built -upon area. 14 Page 1 of 4 State Stormwater Permit Permit No.SW3170101 2. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. 3. This project may not be sold or subdivided in whole or in part without first receiving a permit modification. 4. The following deed restrictions must be recorded with the Office of the Register of Deeds: a. The following covenants are intended to ensure ongoing compliance with State Stormwater Management Permit Number SW3170101. b. The State of North Carolina is made a beneficiary of these covenants to the extent necessary to maintain compliance with the Stormwater Management Permit. C. These covenants are to run with the land and be binding on all persons and parties claiming under them. d. The covenants pertaining to stormwater may not be altered or rescinded without the express written consent of the State. e. Alteration of the drainage as shown on the approved plans may not take place without the concurrence of the State. f. This project may not be sold or subdivided, in whole or in part, without first receiving a permit modification from the Division. h. Construction of additional impervious areas such that low -density requirements are no longer met will require a permit modification prior to construction. An engineered system will be required to collect and treat the runoff from all built -upon area associated with the project, including that area permitted under the low density option. i. Filling in or piping of any vegetative conveyances (ditches, swales, etc.) associated with this development, except for average driveway crossings, is strictly prohibited by any persons. j. The built -upon areas shall be located a minimum of 30 feet landward of all perennial and intermittent surface waters. 5. A copy of the recorded restrictions must be received in this Office within 30 days of the date of sale. 6. Filling in or piping of any vegetative conveyances (ditches, swales, etc.) associated with the permitted development, except for average driveway crossings, is strictly prohibited by any persons. 7. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to the approved plans, regardless of size. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area. e. Further subdivision, acquisition, or sale of the project area in whole or in part. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval was sought. f. Filling in, altering or piping any vegetative conveyance shown on the approved plan. 15 Page 2 of 4 State Stormwater Permit Permit No.SW3170101 8. During construction, erosion shall be kept to a minimum and any eroded areas of the swales or other vegetated conveyances will be repaired immediately. 9. The permittee shall at all times provide the operation and maintenance necessary to operate the permitted stormwater management systems at optimum efficiency to include: a. Inspections b. Sediment removal. c. Mowing, and re -vegetating of the side slopes. d. Immediate repair of eroded areas. e. Maintenance of side slopes in accordance with approved plans and specifications. 10. Within 30 days of completion of the project, the permittee shall certify in writing that the project has been constructed in accordance with the approved plans. 11. The permittee shall submit all information requested by the Director or his representative within the time frame specified in the written information request. III. GENERAL CONDITIONS This permit is not transferable to any person or entity except after notice to and approval by the Director. The Director may require modification or revocation and re -issuance of the permit to change the name and incorporate such other requirements as may be necessary. In the event of a name or ownership change, a completed Name/Ownership Change form, signed by both parties, must be submitted to the State accompanied by the supporting documentation as listed on page 2 of the form. The approval of this request will be considered on its merits, and may or may not be approved. 2. The permittee is responsible for compliance with all permit conditions until the Director approves a transfer of ownership. Neither the sale of the project nor the transfer of common areas to a third party, such as a homeowner's association, constitutes an approved transfer of the stormwater permit. 3. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action in accordance with North Carolina General Statutes 143-215.6A to 143-215.6C. 4. The issuance of this permit does not prohibit the Director from reopening and modifying the permit, revoking and reissuing the permit, or terminating the permit as allowed by the laws, rules, and regulations contained in Session Law 2006- 246, Title 15A of the North Carolina Administrative Code, Subchapter 21-1.1000; and North Carolina General Statute 143-215.1 et. al. 5. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by the State, such as the construction of additional or replacement stormwater management systems. 6. The permittee grants permission to DEQ Staff to enter the property during normal business hours, for the purpose of inspecting all components of the stormwater management facility. 16 Page 3 of 4 State Stormwater Permit Permit No.SW3170101 7. The permit issued shall continue in force and effect until revoked or terminated. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and re -issuance, or termination does not stay any permit condition. 8. Unless specified elsewhere, permanent seeding requirements for the swales must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 9. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 10. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state and federal), which have jurisdiction. 11. The permittee shall notify the Division in writing of any name, ownership or mailing address changes at least 30 days prior to making such changes. Permit issued this the 171h day of January 2017. 0-01W Sued Y lfflclxal f leaadaff for Tracy E. Davis, P.E., CPM Director Division of Energy, Mineral, and Land Resources 17 Page 4 of 4