Loading...
HomeMy WebLinkAboutNC0088722_Application (ATC)_20150508 .461:7A NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Donald R.van der Vaart Governor Secretary May 8, 2015 Don Chamblee Director of Public Works Lincoln County 115 West Main Street Lincolnton, North Carolina 28092 SUBJECT: Authorization to Construct A to C No. 088722A02 Lincoln County Killian Creek WWTP Dear Mr. Chamblee: A letter of request for an Authorization to Construct was received April 14, 2015, by the Division of Water Resources (Division), and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of modifications to the existing 1.68 MGD Killian Creek WWTP, with discharge of treated wastewater into the Killian Creek in the Catawba River Basin. This authorization results in an increase in design capacity to 3.35 MGD, and for expansion to permitted flows of 2.5 MGD and 3.35 MGD under the conditions stated in the NPDES. This authorization is awarded for the construction of the following specific modifications: Addition of ten (10) new retrievable diffuser assemblies, 5 assemblies per each existing sequential batch reactors (SBR), consisting of 30 membrane covered fine diffuser tubes per assembly, piping, and controls; addition of one (1) new SBR 1,100 SCFM at 11.1 PSIG blower, piping, and controls; addition of four (4) new 7.5 HP submersible mixers, two (2) new variable speed 1,040 GPM at 15.8 ft TDH transfer pumps , piping, and controls for the existing post EQ basin; addition of one (1) new automatic backwash cloth disc filter system designed for 4.20 MGD peak flow with an effective cloth filter area of 470.17 ft and nominal 10 µm cloth pore size, backwash pump, drive assembly, piping , and controls; addition of one (1) new dual series bank UV disinfection system designed for peak flow of 8.4 MGD, 4.2 MGD per bank, channel, and controls; addition of one (1) new 544 SCFM at 10.1 PSIG digester blower and modification of two (2) existing digesters blowers to achieve 1,507 SCFM per blower, piping, and controls; installation of a new rotary drum thickener (RDT) system consisting of(2) variable speed 400 GPM at 27 ft TDH RDT thickener pumps, a RDT polymer feed/dilution system with adjustable 9 GPH feed polymer pump with suction lift and polymer dilution system, a RDT inline vortex mixer, a rotary drum thickener with a wash system designed to process 400 GPM of sludge solids from digesters, a 150 GPM at 30 PSIG RDT sludge pump, 1617 Mail Service Center,Raleigh,North Carolina 27699-1617 Location:512 N.Salisbury St.Raleigh,North Carolina 27604 Phone:919-807-63001 Fax:919-807.64921 Customer Service:1-879623-6748 Internet:www.ncwater.org An Equal OpportunitylAffirmative Action Employer Don Chamblee,Director of Public Works May 8,2015 Page 2 of 3 piping, and controls; installation of a new internal reuse water system consisting of a 260 GPM at 28 ft TDH effluent reuse water pump, a 5,500 gallon storage tank, a liquid sodium hypochlorite 1.3 GPH at 25 PSIG chemical feed system with suction lift, three (3) 55 GPM at differential 80 PSIG reuse water booster pumps, piping, and controls; addition of one (1) new 120 GPM sludge pump,piping, and controls; addition of one (1) new rotary sludge press (RSP) system consisting of a RSP polymer feed/dilution system with adjustable 9 GPH polymer feed pump with suction lift and polymer dilution system, a RSP inline flocculator, a rotary sludge press design to produce 600 dry lbs/hr of solids, a RSP 2 HP cake conveyor, piping, and controls; modification of existing waste cake dumpster distribution conveyor to accommodate second dumpster, and controls: in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No. NC0088722 issued effective March 1, 2015, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0088722. The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the Division. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions,the Permittee shall take immediate corrective action, including those as may be required by the Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Mooreville Regional Office, telephone number (704) 663 - 1699, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an on site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct and the approved plans and specifications. Mail the Certification to: NPDES Unit, DWR/DENR, 1617 Mail Service Center, Raleigh,NC 27699-1617. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of T15A:8G.0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III and N facility at least daily, excluding weekends and holidays, must properly manage the facility, must document daily operation and maintenance of the facility, and must comply with all other conditions of T15A:8G.0202. A Don Chamblee,Director of Public Works May 8,2015 Page 3 of 3 A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. During the construction of the proposed additions/modifications, the permittee shall continue to properly maintain and operate the existing wastewater treatment facilities at all times, and in such a manner, as necessary to comply with the effluent limits specified in the NPDES Permit. You are reminded that it is mandatory for the project to be constructed in accordance with the North Carolina Sedimentation Pollution Control Act, and when applicable, the North Carolina Dam Safety Act. In addition,the specifications must clearly state what the contractor's responsibilities shall be in complying with these Acts. Prior to entering into any contract(s) for construction, the recipient must have obtained all applicable permits from the State. Failure to:abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal)which have jurisdiction. If you have any questions or need additional information, please contact Ron Berry at telephone number(919) 807-6396. Sincerely, tgf/rt • S. Jay Zimmerman Director, Division of Water Resources cc: Charles R. Froneberger, P.E. W. K. Dickson&Co., Inc. 616 Colonnade Drive Charlotte,NC 28205 DWR/Mooresville Regional Office, Water Quality Programs Central Files NPDES File Without Engineer's Certificate attached: Lincoln County Health Department Lincoln County Killian Creek WWTP Authorization to Construct No. 088722A02 Issued May 8, 2015 Engineer's Certification I, , as a duly registered Professional Engineer in the State of North Carolina,having been authorized to observe (periodically/weekly/full time) the construction of the modifications and improvements to the Killian Creek Wastewater Treatment Plant, located in Lincoln County, hereby state that,to the best of my abilities, due care and diligence was used in the observation of the following construction: Addition of ten (10) new retrievable diffuser assemblies, 5 assemblies per each existing sequential batch reactors (SBR), consisting of 30 membrane covered fine diffuser tubes per assembly, piping, and controls; addition of one (1) new SBR 1,100 SCFM at 11.1 PSIG blower, piping, and controls; addition of four (4) new 7.5 HP submersible mixers, two (2) new variable speed 1,040 GPM at 15.8 ft TDH transfer pumps,piping, and controls for the existing post EQ basin; addition of one (1) new automatic backwash cloth disc filter system designed for 4.20 MGD peak flow with an effective cloth filter area of 470.17 ft2 and nominal 10 gm cloth pore size, backwash pump, drive assembly, piping , and controls; addition of one (1) new dual series bank UV disinfection system designed for peak flow of 8.4 MGD, 4.2 MGD per bank, channel, and controls; addition of one (1) new 544 SCFM at 10.1 PSIG digester blower and modification of two (2) existing digesters blowers to achieve 1,507 SCFM per blower, piping, and controls; installation of a new rotary drum thickener (RDT) system consisting of (2) variable speed 400 GPM at 27 ft TDH RDT thickener pumps, a RDT polymer feed/dilution system with adjustable 9 GPH feed polymer pump with suction lift and polymer dilution system, a RDT inline vortex mixer, a rotary drum thickener with a wash system designed to process 400 GPM of sludge solids from digesters, a 150 GPM at 30 PSIG RDT sludge pump, piping, and controls; installation of a new internal reuse water system consisting of a 260 GPM at 28 ft TDH effluent reuse water pump, a 5,500 gallon storage tank, a liquid sodium hypochlorite 1.3 GPH at 25 PSIG chemical feed system with suction lift, three (3) 55 GPM at differential 80 PSIG reuse water booster pumps, piping, and controls; addition of one (1) new 120 GPM sludge pump, piping, and controls; addition of one (1) new rotary sludge press (RSP) system consisting of a RSP polymer feed/dilution system with adjustable 9 GPH polymer feed pump with suction lift and polymer dilution system, a RSP inline flocculator, a rotary sludge press design to produce 600 dry lbs/hr of solids, a RSP 2 HP cake conveyor, piping, and controls; modification of existing waste cake dumpster distribution conveyor to accommodate second dumpster, and controls: in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. Upon receipt of this signed certificate, the design capacity of this facility is authorized to increase to 3.35 MGD. Expansion for designated permitted flows will be determined by conditions in the NPDES. Authorization to Construct No. 088722A02 Issued May 8, 2015 Page 2 of 2 I certify that the construction of the above referenced project was observed to be built within substantial compliance,intent and in conformity with all applicable regulations and statutes and the project plans, specifications,and other supporting documentation comprising the Authorization to Construct Permit Application package. Signature Registration No. Date Mail this Certification to: Attn: Ron Berry SEAL Complex Permitting Unit DENR/DWR/Water Quality Programs 1617 Mail Service Center Raleigh,NC 27699-1617