HomeMy WebLinkAboutNCC231307_Site Plan or Location Map_20230503 g` SUMMARY INFORMATION RIM
_• �.,.xN,.O /$ DEVELOPMENT NAME:WHITE STREET VILLAGE
« SITE ADDRESS: 150 N WHITE ST,WAKE FOREST,NC
u iff„ "
„„ so° x PIN NUMBER(S): 1841-52-4174
,,,�„ .c `"^a. TOTAL AREA: 3.10 AC ENGINEERING
LESS N WHITE ST RIW DEDICATION:0.06 AC
S. I„ •��� �� ���� NET AREA:3.04 AC
''.ngHR, CONSTRUCTION PLANS
m /, . _ PT OFFICE BOX 91727
EXISTING USE:COMMERCIAL RALEIToOoHS.,NORTH CAROLINA 27675
r' SITE PROPOSED USE: MULTI FAMILY CONDOMINIUMS
i s PHONE:919.610.1051
W p„.,.,_.,9,...",.,� „ THE wence JURISDICTION:TOWN OF WAKE FOREST FIRM C LICENSE NUMBER C-4222
„34 .'0a EXISTING ZONING DISTRICT:UMX
STHA� ne..M t..,.,, FOR 200 COMMUNITY PLAN GROWTH STRATEGIES DESIGNATION: HISTORIC ,I P.....
" _ „-, `
// N TOWN COREMINN
rk ••� ARO '
�/ PROPOSED UNITS::72 NIA
�5510'•:I/,°
w. UMX MAX.DENSITY:N/A 7
_ .,/ M r PROPOSED DENSITY:23.2 UNITS/ACRE -_'
• ��•o fl
°� UMX.MIN.HEIGHT:2 STORIES _ 033775 L�1)Cr--
is,'
\" . 0
UMX.MAX.HEIGHT:6 STORIES =,' , BH IIN��PQti;
• x _ +.. > PROPOSED HEIGHT:48',4 STORIES ti'`/>•
NAN O
V I C I N I TY MAP EXISTING BUILDING AREA:34,861 SF
PROPOSED BUILDING AREA:345,600 SF(86,400 SF PER STORY)
1"=1000' WHITE ST VILLAGE UMX REQUIRED PRIMARY ST FRONTAGE BUILDOUT:70%(533 LF OF N WHITE
ST FRONTAGE X 0.7=373 LF)
PROPOSED FRONTAGE BUILDOUT: 81%(432 LF BUILDOUT/533 LF FRONTAGE REVISION HISTORY
ALL PUBLIC FACILITIES,INCLUDING SIDEWALKS,AND HANDICAP RAMPS ARE =0.81)
TO BE CONSTRUCTED ON ALL STREETS AS SPECIFIED BY TOWN REV DESCRIPTION DATE BY
STANDARDS.THESE FACILITIES HAVE BEEN APPROVED BY THE TOWN OF UMX SETBACKS: ry
WAKE FOREST AND SHALL BE SO INSTALLED UNLESS A CHANGE IS FRONT:6'MAX.
APPROVED BY THE TOWN OF WAKE FOREST. SIDE STREET:6'MAX. 1 TOWF COMMENTS 5/12/2022 FLM
SIDE:0'MIN. 2 TOWF COMMENTS 9/6/2022 FLM
SP -21 REAR:0'MIN.
ALL PUBLIC UTILITIES ARE TO BE CONSTRUCTED AS SPECIFIED BY CITY OF 3 TOWF COMMENTS 1/18/2023 FLM
MULTI-FAMILY PARKING CALCULATIONS:
RALEIGH STANDARDS.THESE UTILITIES HAVE BEEN APPROVED BY THE CITY REQUIRED PARKING: 1.8 PER UNIT=1.8 X 72 UNITS=130 SPACES 4 TOWF COMMENTS 3/16/2023 FLM
OF RALEIGH AND SHALL BE SO INSTALLED UNLESS A CHANGE IS APPROVED
BY THE CITY OF RALEIGH. PROVIDED PARKING:2 SPACES PER UNIT(SINGLE-CAR GARAGE AND
SINGLE-CAR DRIVEWAY)+33 OFF-STREET PARKING SPACES+15 ON-STREET
PARKING SPACES=2 X 72 UNITS+35+15=192 SPACES
EXECUTION OF THIS CONSTRUCTION PLAT BY THE REVIEW ENGINEER FOR REQUIRED MAIL KIOSK PARKING:2 SPACES(1 ADA)
THE TOWN OF WAKE FOREST IN NO WAY LIMITS THE RESPONSIBILITY OF THE PROVIDED MAIL KIOSK PARKING:2 SPACES(1 ADA)
OWNER AND ENGINEER OF RECORD WITH REGARD TO COMPLIANCE WITH
MULTI-FAMILY BICYCLE PARKING CALCULATIONS:
ALL FEDERAL,STATE,AND LOCAL STANDARDS AND/OR CONDITIONS. REQUIRED PARKING:2 PER 40 AUTO SPACES;193 SPACES=10 BICYCLE
PARKING SPACES REQUIRED
OWNER HEREBY CERTIFIES AND AGREES TO TAKE SUCH ACTION AS MAY BE `/n\/ PROVIDED PARKING: 10 SPACES
REQUIREDMISSOO BY THE TOWN LIF WAKE FORESTH TCORRECT DARANY ERRORS,
150 N Y Y H ITE ST
OMISSIONS OR NON-COMPLIANCE WITH TOWN STANDARDS AND/OR UMX REQUIRED OPEN PACE: N/A(PROJECT LESS THAN 5 ACRES)
CONDITIONS DESCRIBED IN THIS CONSTRUCTION PLAT,INCLUDING PROPOSED OPEN SPACE: 84,431 SF,1.94 AC
RE-SUBMISSION OR RE-EXECUTION OF THIS CONSTRUCTION PLAT WITH THE
UMX REQUIRED PARK SPACE: N/A(PROJECT LESS THAN 5 ACRES)
APPROPR T ORRECTIONS AND/OR REVISIONS. WAKE FOREST NORTH CAROLINA
, PROPOSED PARK SPACE: N/A
EXISTING IMPERVIOUS AREA: 103,697 SF,2.38 AC(76.7%)
: 9!7/22 PROPOSED IMPERVIOUS AREA:95,080 SF,2.18 AC(70.3%) ORIGINAL PLAN SIZE:24"X 36"
OWNER DATE PIN : 1841 -52-4174
PROPOSED LINEAR FOOTAGE QUANTITIES
UTILITY 1 OWNERSHIP DIAMETER!MATERIAL LENGTH
SANITARY SHEET TITLE
PRIVATE 6"41 SDR35 PVC 517•
SEWER
SANITARY C-1 COVER
SEWER PUBLIC 8"0 DIP 452' C-2 NOTES
WATER PUBLIC 8"0 DIP 484' C-3 CALCULATIONS
C-4 EXISTING CONDITIONS&DEMOLITION PLAN
STORM PRIVATE VARIES 1906' C-5 SITE PLAN
DRAIN
ALLEY PRIVATE - 1,200' C-6 UTILITY PLAN
C-7 GRADING&DRAINAGE PLAN
CURB& PUBLIC(WITHIN R/W) 30"STANDARD 60'
GUTTER C-8 EROSION&SEDIMENT CONTROL PLAN-PHASE I
CURB& PUBLIC(WITHIN R/W) 6"CURB 333' C-9 EROSION&SEDIMENT CONTROL PLAN-PHASE II
GUTTER C-10 LANDSCAPING PLAN
SIDEWALK PUBLIC 6' 114' C-11 LIGHTING PLAN SCALE ADJUSTMENT
SIDEWALK PUBLIC 10' 505' C-12 SEWER MAIN PLAN&PROFILE THIS BAR IS 1 INCH IN LENGTH
C-13 WATER MAIN PLAN&PROFILE ON ORIGINAL DRAWING
NOTE:ALL PRIVATE WATER/SEWER IS REQUIRED TO BE PERMITTED AND INSPECTED BY THE TOWN 0 1"
OF WAKE FOREST INSPECTIONS. C-14 SITE DETAILS
C-15 SITE DETAILS IF IT IS NOT 1 INCH ON THIS
C-16 STORM DRAINAGE DETAILS SHEET,ADJUST
ACCORDINGLYY
SCA E
C-17 EROSION&SEDIMENT CONTROL DETAILS
C-18 EROSION&SEDIMENT CONTROL DETAILS CONSTRUCTION PLANS
C-19 WATER DETAILS SP-21-36
C-20 SEWER DETAILS
DEVELOPER: ENGINEER OF RECORD: C-21 SELF-INSPECTION RECORDKEEPING&REPORTING
WHITE STREET VILLAGE
C-22 GROUND STABILIZATION&MATERIALS HANDLING
ATTENTION CONTRACTORS AGNC VENTURES I,LLC FLM ENGINEERING, INC N WHITE ST
CONTACT:JACOB ANDERSON CONTACT:JON FRAZIER,PE WAKE FOREST,NC
THE CONSTRUCTION CONTRACTOR RESPONSIBLE FOR THE EXTENSION OF 7208 FALLS OF NEUSE RD,STE 101 PO BOX 91727
WATER,SEWER,AND/OR REUSE,AS APPROVED IN THESE PLANS,IS
RESPONSIBLE FOR CONTACTING THE PUBLIC UTILITIES DEPARTMENT AT RALEIGH,NC 27615 RALEIGH,NC 27675
(919)996-4540 AT LEAST TWENTY FOUR HOURS PRIOR TO BEGINNING ANY OF 919.239.9486 919.610.1051
THEIR CONSTRUCTION. JACOB@ALLIANCEGROUPNC.COM JFRAZIER@FLMENGINEERING.COM
AGNC VENTURES I,LLC
FAILURE TO NOTIFY BOTH CITY DEPARTMENTS IN ADVANCE OF BEGINNING
CONSTRUCTION,WILL RESULT IN THE ISSUANCE OF MONETARY FINES,AND WATER AND SEWER PERMITS
REQUIRE REINSTALLATION OF ANY WATER OR SEWER FACILITIES NOT THE CITY OF RALEIGH CONSENTS TO THE CONNECTION AND EXTENSION OF THE CITY'S PUBUC SEWER
INSPECTED AS A RESULT OF THIS NOTIFICATION FAILURE. SYSTEM AS SHOWN ON THIS PLAN.THE MATERIAL AND CONSTRUCTION METHODS USED FOR THIS PROJECT
SHALL CONFORM TO THE STANDARDS AND SPECIFICATIONS OF THE CITY'S PUBLIC UTILITIES HANDBOOK. DATE: 03-18-2022
FAILURE TO CALL FOR INSPECTION,INSTALL A DOWNSTREAM PLUG,HAVE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT PERMITU Sd12T
PERMITTED PLANS ON THE JOBSITE,OR ANY OTHER VIOLATION OF CITY OF THE CITY OF RALEIGH CONSENTS TO THE CONNECTION AND EXTENSION OF THE CITY'S PUBUC WATER SCALE: AS SHOWN
RALEIGH STANDARDS WILL RESULT IN A FINE AND POSSIBLE EXCLUSION SYSTEM AS SHOWN ON THIS PLAN.THE MATERIAL AND CONSTRUCTION METHODS USED FOR THIS PROJECT DESIGNED BY: FLM
FROM FUTURE WORK IN THE CITY OF RALEIGH. SHALL CONFORM TO THE STANDARDS AND SPECIFICATIONS OF THE CITY'S PUBLIC UTILITIES HANDBOOK.
CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT PERMIT B W3980 APPROVED BY: FLM
THE CITY OF RALEIGH CONSENTS TO THE CONNECTION TO ITS PUBLIC SEWER SYSTEM AND EXTENSION OF
THE PRIVATE SEWER COLLECTION SYSTEM AS SHOWN ON THIS PLAN.THE MATERIAL AND CONSTRUCTIONS PROJECT NO.: 21048
CALL 48 HOURS BEFORE THESE PLANS
HAVE BEEN
EENELECTR ELECTRONICALLY
APPROVED
NOR CO DEPARTMENT.IOBCITY'S USEDS F T HANDBOOK
IS PROJECT SHALL CONFORM TO THE STANDARDS AND SPECIFICATIONS OF THE
THEE OW
YOU DIG THIS APPROVAL MAY NOT BE EDITED ONCE ISSUED. CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT PERMIT II S-SlURP)
/yH (' M°''AMSBIDB COVER
North8� '^/E WORKS/ENGINEERING
CITY OF RALEIGH-PLANS AUTHORIZED FOR CONSTRUCTION
PUBLIC WORKSIENGINEERING
I l i n ELECTRONIC APPROVAL THIS APPROVAL IS BEING ISSUED ELECTRONICALLY.THIS APPROVAL IS VALID ONLY
UPON THE SIGNATURE OF A CITY OF RALEIGH REVIEW OFFICER BELOW.THE CITY WILL RETAIN A COPY OF
W WW.NE811.O18'. , THESE PLANS HAVE BEEN ELECTRONICALLY APPROVED FOR CONSTRUCTION BY THE APPROVED PLANS.ANY WORK AUTHORIZED BY THIS APPROVAL MUST PROCEED IN ACCORDANCE WITH
ALL CONSTRUCTION TO BE IN ACCORDANCE THE TOWN OF WAKE FOREST PLANNING DEPARTMENT.THIS APPROVAL MAY NOT THE PLANS KEPT ON FILE WITH THE CITY.THIS ELECTRONIC APPROVAL MAY NOT BE EDITED ONCE ISSUED.
NORTH CAROLINA BE EDITED ONCE ISSUED. ANY MODIFICATION TO THIS APPROVAL ONCE ISSUED WILL INVALIDATE THIS APPROVAL
WITH ALL TOWN OF WAKE FOREST,CITY OF
ONE-CALL CENTER RALEIGH,AND NCDOT STANDARDS AND N4"7/202G272
3 CITY OF RALEIGH DEVELOPMENT APPROVAL
1-800-632-4949 SPECIFICATIONS. PLANNING04/1 SHEET 1 OF22
RALEIGH WATER REVIEW OFFICER
02023 THIS DRAWING SHALL NOT BE REPRODUCED IN WHOLE OR IN
PART WITHOUT WRITTEN PERMISSION OF FLM ENGINEERING,INC.