HomeMy WebLinkAboutWQCS00008_Burlington_Collection_System_CEI_Letter_20230410ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director City of Burlington Attn: David Cheek, Interim City Manager P.O. Box 1358 Burlington, NC 27216-1358 NORTH CAROLINA Environmental Quality April 10, 2023 SUBJECT: Compliance Evaluation Inspection City of Burlington Wastewater Collection System Wastewater Collection System Permit #: WQCS00008 Alamance County Ron Boone and Jesse Barnes, of the Winston-Salem Regional Office (WSRO) of the NC Division of Water Resources (DWR or the Division), conducted a compliance evaluation inspection of the City of Burlington's wastewater collection system on March 23rd, 2023. They met with Donny West, Andy McCoy, and Travis Moore for the inspection. Inspection findings are summarized below and are detailed in the attached compliance inspection report. Mr. Boone and Mr. Barnes noted no violations during the inspection. The only item of concern noted during the inspection was the vegetation overgrowth on the Pace Drive aerial. This aerial is 8" ductile iron pipe and is about 280' long. This aerial appears to be in good condition and functioning properly but should be cleared of vegetation. No further action is required, however, you are reminded that in accordance with NC General Statute 143- 215.6A, a civil penalty of not more than twenty-five thousand dollars ($25,000) may be assessed by the Secretary of the Division of Water Resources against any person who is required but fails to apply for or to secure a permit required by NCGS 143-215.1, or who violates or fails to act in accordance with the terms, conditions, or requirements of such permit. If you have any questions or concerns, please contact Mr. Boone by phone at 336.776.9690 or by email at ron.boone@ncdenr.gov. Thank you for your time and immediate attention to these issues. Sincerely, DocuSi?gned by: 145B49E225C94EA... Lon T. Snider, Regional Supervisor Water Quality Regional Operations Section Winston-Salem Regional Office Division of Water Resources, NCDEQ Attachments: Compliance Inspection Report DffNorth Carolina Department of Environmental Quality I Division of Water Resources oan caaouNn Winston-Salem Regional Office 1 450 W. Hanes Mill Rd, Suite 300 I Winston-Salem, North Carolina 27105 M336.776.9800 oep.m.m or em�nmen� Qualm Compliance Inspection Report Permit: WQCS00008 Effective: 10/01/16 Expiration: 09/30/24 Owner: City of Burlington SOC: Effective: Expiration: Facility: Burlington Collection System County: Alamance 234 E Summit Ave Region: Winston-Salem Burlington NC 27215 Contact Person: Michael Scott Layne Title: Water & Sewer Field Ops Mgr. Phone: 336-222-5140 Directions to Facility: System Classifications: CS3, Primary ORC: Donnie Lee West Certification: 29078 Phone: 336-222-5140 Secondary ORC(s): On -Site Representative(s): Related Permits: NCO023876 City of Burlington - Southside WWTP NCO023868 City of Burlington - Eastside WWTP Inspection Date: 03/23/2023 Entry Time 09:30AM Exit Time: 01:30PM Primary Inspector: Ron Boone E�Oa ocusi9ned by: Phone: 336-776-9690 Secondary Inspectors): naBoo.u*4/10/2023 20F8DD5F2A3460... Jesse Barnes Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation Facility Status: Compliant Not Compliant Question Areas: Miscellaneous Questions General Sewer & FOG Ordinances Capital Improvement Plan Map Reporting Requirements Inspections Spill Response Plan Spills Lines Manholes Pump Stations (See attachment summary) Page 1 of 7 Permit: WQCS00008 Owner - Facility: City of Burlington Inspection Date: 03/23/2023 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: On March 23rd, 2023, Ron Boone and Jesse Barnes, of the NC Division of Water Resources (DWR or the Division), conducted a compliance evaluation inspection of the City of Burlington's wastewater collection system. Mr. Boone and Mr. Barnes met with operators Donny West, Andy McCoy, and Travis Moore. Inspection findings are summarized below and detailed in the attached compliance inspection report. No violations were noted during the inspection. The only item of concern noted during the inspection was the vegetation overgrowth on the Pace Drive aerial. This aerial is 8' ductile iron pipe and is about 280' long. This aerial appears to be in good condition and functioning properly but should be cleared of vegetation. No other issues were noted during the inspection. You are reminded that in accordance with NC General Statute 143-215.6A, a civil penalty of not more than twenty-five thousand dollars ($25,000) may be assessed by the Secretary of the Division of Water Resources against any person who is required but fails to apply for or to secure a permit required by NCGS 143-215.1, or who violates or fails to act in accordance with the terms, conditions, ore requirements of such permit. If you have any questions or concerns, please contact Mr. Boone by phone at 336.776.9690 or by email at ron.boone@ncdenr.gov. Thank you for your time and immediate attention to these issues. Page 2 of 7 Permit: WQCS00008 Owner - Facility: City of Burlington Inspection Date: 03/23/2023 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine General Yes No NA NE Is there a properly designated primary ORC and at least one back-up of proper grade? 0 ❑ ❑ ❑ Are logs being reviewed by the system management or owner on a regular basis? 0 ❑ ❑ ❑ # What is that frequency? As generated # Are there any issues being addressed currently or any in the planning stages? 0 ❑ ❑ ❑ Is there a specific pump failure plan available for all pump stations? 0 ❑ ❑ ❑ Does plan indicate if pump parts/new pumps are in spare parts/equipment inventory? 0 ❑ ❑ ❑ Are new/significantly upgraded pump stations equipped with anti -corrosion materials? 0 ❑ ❑ ❑ Does the permittee have a copy of their permit? 0 ❑ ❑ ❑ # Is permit expiring within the next 6 months? ❑ 0 ❑ ❑ If Yes, has the Permittee applied for renewal? ❑ ❑ 0 ❑ Comment: None Sewer and FOG Ordinances Yes No NA NE Is Sewer Use Ordinance (SUO) or other Legal Authority available? 0 ❑ ❑ ❑ Does it appear that the Sewer Use Ordinance is enforced? 0 ❑ ❑ ❑ Is there a Grease Control Program that legally requires grease control devices? 0 ❑ ❑ ❑ What is the standard grease trap cleaning requirement in the FOG ordinance? Annually Is Grease Control Program enforced via periodic inspections/records review? 0 ❑ ❑ ❑ Is action taken against violators? 0 ❑ ❑ ❑ # Have satellite systems adopted an equivalent or more stringent ordinance? 0 ❑ ❑ ❑ Is grease/sewer education program documented with req'd customer distribution? 0 ❑ ❑ ❑ # Are other types of education tools used like websites, booths, special meetings, etc? 0 ❑ ❑ ❑ If Yes, what are they? (This can reduce mailing to annual.) Website, events Comment: None Capital Improvement Plan Yes No NA NE Has a Capital (CIP) or System Improvement Plan been developed and adopted? ❑ ❑ ❑ Is it designated for wastewater only or does it have a dedicated section? ❑ ❑ ❑ Does CIP cover three to five year period of earmarked improvements? ❑ ❑ ❑ Does CIP include description of project area? ❑ ❑ ❑ Does CIP include description of existing facilities? ❑ ❑ ❑ Does CIP include known deficiencies? ❑ ❑ ❑ Does CIP include forecasted future needs? 0 ❑ ❑ ❑ Comment: CIP covers 2022-2028 Map Yes No NA NE Page 3 of 7 Permit: WQCS00008 Owner - Facility: City of Burlington Inspection Date: 03/23/2023 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Is there a overall sewer system map? 0 ❑ ❑ ❑ Does the map include: Pipe Type (GS/FM) 0 ❑ ❑ ❑ Pipe sizes 0 ❑ ❑ ❑ Pipe materials (PVC, DIP, etc) 0 ❑ ❑ ❑ Pipe location 0 ❑ ❑ ❑ Flow direction 0 ❑ ❑ ❑ Approximate pipe age 0 ❑ ❑ ❑ Pump station ID, location and capacity 0 ❑ ❑ ❑ # Force main air release valve location & type 0 ❑ ❑ ❑ # Location of satellite connections 0 ❑ ❑ ❑ Is the map being updated for changes/additions within 1 year of activation? 0 ❑ ❑ ❑ Comment: Very high quality GIS map. Data is constantly collected and added to the system. Reporting Requirements Yes No NA NE # Have there been any sewer spills in the past 3 years? ❑ ❑ ❑ If Yes, were they reported to the Division if meeting the reportable criteria? ❑ ❑ ❑ If applicable, is there documentation of press releases and public notices issued? ❑ ❑ ❑ Is an Annual Wastewater Performance Report being filed with the Division, if required? ❑ ❑ ❑ Is the report being made available to all its sewer customers? ❑ ❑ ❑ # How is it being made available? Website Comment: None Inspections Yes No NA NE Are adequate maintenance records maintained? ❑ ❑ ❑ Are pump stations being inspected at the required frequency? ❑ ❑ ❑ # Is at least one complete functionality test conducted weekly per pump station? ❑ ❑ ❑ Is there a system or plan in place to observe the entire system annually? ❑ ❑ ❑ Is the annual inspection documented? ❑ ❑ ❑ # Does the system have any high -priority lines/locations? ❑ ❑ ❑ Are inspections of HPL documented at least every 6 months? ❑ ❑ ❑ Are new lines being added to the HPL list when found or created? ❑ ❑ ❑ Comment: None Spill Response Action Plan Yes No NA NE Is a Spill Response Action Plan available? ❑ ❑ ❑ Is a Spill Response Action Plan available for all personnel? ❑ ❑ ❑ Does the plan include: Page 4 of 7 Permit: WQCS00008 Owner - Facility: City of Burlington Inspection Date: 03/23/2023 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine 24-hour contact numbers 0 ❑ ❑ ❑ Response time 0 ❑ ❑ ❑ Equipment list and spare parts inventory 0 ❑ ❑ ❑ Access to cleaning equipment 0 ❑ ❑ ❑ Access to construction crews, contractors, and/or engineers 0 ❑ ❑ ❑ Source of emergency funds 0 ❑ ❑ ❑ Site sanitation and cleanup materials 0 ❑ ❑ ❑ Post-overflow/spill assessment 0 ❑ ❑ ❑ Does the Permittee appear to respond within 2 hours of first knowledge of a spill? 0 ❑ ❑ ❑ Comment: None $RiL Yes No NA NE Is system free of known points of bypass? 0 ❑ ❑ ❑ If No, describe type of bypass and location Are all spills or sewer related issues/complaints documented? 0 ❑ ❑ ❑ # Are there repeated overflows/problems (2 or more in 12 months) at same location? ❑ 0 ❑ ❑ # If Yes, is there a corrective action plan? ❑ ❑ 0 ❑ Comment: None Lines/Right-of-Ways/Aerial Lines Yes No NA NE Please list the Lines/Right of Ways/Aerial Lines Inspected: Pace Drive Aerial, 280' of 8" ductile iron, good condition but needs to be cleared of vegetation. South River View Aerial, 150' of 8" ductile iron pipe, good condition. City currently has a total of 119 high priority lines. Are right-of-ways/easements maintained for full width for access by staff/equipment? ❑ ❑ ❑ If No, give details on temporary access: Is maintenance documented? ❑ ❑ ❑ Are gravity sewer cleaning records available? ❑ ❑ ❑ Has at least 10% of lines older than 5 yrs been cleaned annually? ❑ ❑ ❑ Were all areas/lines inspected free of issues? N ❑ ❑ ❑ Comment: 120 miles cleaned '21-'22. 101 miles cleaned so far in '22-'23. Manholes Yes No NA NE Please list the Manholes Inspected: None Are manholes accessible? ❑ ❑ ❑ # Are manhole covers/vents above grade? ❑ ❑ ❑ Are manholes free of visible signs of overflow? ❑ ❑ ❑ Are manholes free of sinkholes and depressions? ❑ ❑ ❑ Are manhole covers present? ❑ ❑ ❑ Page 5 of 7 Permit: WQCS00008 Owner - Facility: City of Burlington Inspection Date: 03/23/2023 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine # Are manholes properly seated? 0 ❑ ❑ ❑ # Are manholes in good condition? ❑ ❑ ❑ # Are inverts in good condition? ❑ ❑ ❑ Is flow unrestricted in manholes? ❑ ❑ ❑ Are manholes free of excessive amounts of grease? ❑ ❑ ❑ Are manholes free of excessive roots? ❑ ❑ ❑ Are manholes free of excessive sand? ❑ ❑ ❑ Are manhole vents screened? ❑ ❑ ❑ Are vents free of submergence? ❑ ❑ ❑ Are manholes free of bypass structures or pipes? ❑ ❑ ❑ Comment: None Pump Stations Yes No NA NE Please list the Pump Stations Inspected: Whitsett Pace Dr Pump Station; Dry Creek Pump Station # Number of duplex or larger pump stations in system 4 # Number of vacuum stations in system 0 # Number of simplex pump stations in system 0 # Number of simplex pump stations in system serving more than one building 0 How many pump/vacuum stations have: # A two-way "auto polling" communication system (SCADA) installed? 4 # A simple one-way telemetry/communication system (auto -dialer) installed? 0 For pump stations inspected: Are they secure with restricted access? ❑ ❑ ❑ Were they free of by-pass structures/pipes? ❑ ❑ ❑ Were wet wells free of excessive grease/debris? ❑ ❑ ❑ # Do they all have telemetry installed? ❑ ❑ ❑ Is the communication system functional? ❑ ❑ ❑ Is a 24-hour notification sign posted ? ❑ ❑ ❑ Does the sign include Owner Name? ❑ ❑ ❑ Pump station identifier? ❑ ❑ ❑ # Address? ❑ ❑ ❑ Instructions for notification? ❑ ❑ ❑ 24-hour emergency contact numbers? ❑ ❑ ❑ Are audio and visual alarms present? ❑ ❑ ❑ Are audio and visual alarms operable? ❑ ❑ ❑ Page 6 of 7 Permit: WQCS00008 Owner - Facility: City of Burlington Inspection Date: 03/23/2023 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine # Is there a backup generator or bypass pump connected? If tested during inspection, did it function properly? Is the back-up system tested at least bi-annually under normal operating conditions? # Does it have a dedicated connection for a portable generator? # Is the owner relying on portable units in the event of a power outage? # If Yes, is there a distribution plan? If Yes, what resources (Units/Staff/Vehicles/etc) are included in Plan? # Does Permittee have the approved percentage of replacement simplex pumps? Is recordkeeping of pump station inspection and maintenance program adequate? Do pump station logs include at a minimum: Inside and outside cleaning and debris removal? Inspecting and exercising all valves? Inspecting and lubricating pumps and other equipment? Inspecting alarms, telemetry and auxiliary equipment? Comment: None • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑■❑❑ ❑■❑❑ ❑❑■❑ ❑❑■❑ ■❑❑❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 7 of 7