Loading...
HomeMy WebLinkAboutNCG030039_2022 DMR_20221018 i DAIMLER Garrett Christy Sr.Environmental Engineer Daimler Trucks 11550 Statesville Blvd Cleveland,NC 27013 704.645.5353 Phone October 18, 2022 Division of Water Quality Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, NC 28115 To whom it may concern: Please find enclosed stormwater sampling results for Stormwater Discharge Outfalls#001 and #002 for the Cleveland facility in the month of September 2022. The September 30th sampling event showed no exceedance for Zinc or Copper at Outfall #001, but #002 showed exceedance for Zinc. Should you have any questions, please contact me at 704-645-5353 or garrett.christy@daimlertruck.com. Sincerely, Daimler Trucks, LLC Garrett Christy Sr. Environmental Engineer SHIELD ENGINEERING October 17,2022 Ms. Christy Garrett Daimler Truck North America, LLC 11550 Statesville Boulevard Cleveland, NC 27013 Subject: Stormwater Sampling—September 2022 NPDES General Permit No. NCG030000/CoC No. NCG030039 Daimler Truck North America, LLC 11550 Statesville Boulevard,Cleveland,North Carolina Shield Project No.1140111-10 Dear Ms. Garrett: Shield Engineering, Inc. (Shield) successfully collected stormwater samples for Stormwater Discharge Outfalls SDO#001 and SDO #002 at the Cleveland facility for the month of September 2022. During the September 30t'sampling event,Shield's field measurements of pH were 8.1 at SDO#001 and 7.4 at SDO #002 .The analytical results of the stormwater samples collected during the qualifying storm event'are attached to this cover letter. In addition,the Qualitative Monitoring Report(QMR)forms and the partially completed Discharge Monitoring Report (DMR) forms are attached to this cover letter. The Qualitative Monitoring Report for SDO#002 notes that stormwater is flowing around the rip-rap and not through the rip-rap lined channel. The QMRs should be kept onsite. Analytical results from the sampling event show an exceedance of Zinc at SDO#002. Daimler's Cleveland facility has exited Tier Three at SDO#001 for Copper and is monitored on a quarterly basis. The facility remains in Tier Three of the NPDES General Permit No. NCG030000 at SDO #002 for Copper and Zinc.Shield greatly appreciates the opportunity to provide environmental services to Daimler Truck North America. If you have any questions in reference to this document or require further information, please feel free to contact undersigned at(704)394-6913. Respectfully, SHIELD ENGINEERING,INC. Magdaline Tzannis Robert L.GO E. Senior Project Manager VP NC Operations Melin a Greene Senior Engineer Attachment: Discharge Monitoring Report—September 2022 'Rainfall data collected from onsite rain gauge by DTNA-Cleveland. i i i 4301 Taggart Creek Road www.shieldengineering.com Telephone 704.394.6913 i License No. F-0856 Charlotte, NC 28208 NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report(DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete,sign,scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report(DMR) Upload form within 30 days of receiving sampling results. Mail the original,signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0039 Person Collecting Samples: Kevin Stachura/Shield Engineering,Inc. Facility Name:Daimler Truck NA-Cleveland,NC Laboratory Name: Pace Analytical Facility County: Rowan Laboratory Cert. No.:329 Discharge during this period:E✓ Yes 0 No (if no,skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances?E]Yes 0 No If so,which Tier(I,II,or III)? III A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR [Dyes ONo Date Uploaded: 10/18/22 Analytical Monitoring Requirements for Outfalls with Industrial Activities—Benchmarks in(Red) Parameter Parameter Outfall001 Outfall002 Outfall Outfall Outfall Code N/A Receiving Stream Class C C N/A Date Sample Collected MM/DD/YYYY 9/30/2022 9/30/2022 46529 24-Hour Rainfall in inches 1.97 1.97 C0530 TSS in mg/L(100 or 50*) 6.4 <10 00400 pH in standard units(6.0-9.0 FW, 8.1 7.4 6.8-8.5 SW) 01119 Copper,total recoverable in mg/L 0.0034 0.0065 (0.010 FW,0.0058 SW) 01051 Lead,total recoverable in mg/L 0.00033 0.00095 (0.075 FW,0.22 SW) Zinc,total recoverable in mg/L(0.126 01094 FW,0.095 SW) 0.037 0.130 00340 Chemical Oxygen Demand(COD)in <20 31 mg/L(120) 00552 Non-Polar Oil&Grease in mg/L(15) <5.0 <5.1 * Outfalls to Outstanding Resource Waters(ORW),High Quality Waters(HQW),Trout Waters(Tr)and Primary Nursery Areas(PNA) have a benchmark TSS limit of 50 mg/L.All other water classifications have a benchmark of 100 mg/L FW(Freshwater)SW(Saltwater) Notes(optional): September 2022: Benchmark exceedance of Zinc at SDO 002. "I certify by my signature below,under penalty of law,that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted.Based on my inquiry of the person or persons who manage the system,or those persons directly responsible for gathering the information,the information submitted is,to the best of m owledge and belief,true,accurate,and complete.I am aware that there are significant penalties for submitting false info ion,includin a possibility of fines and imprisonment for knowing violations." � zz nature a ittee or Delegated Authorized Individual Date craig.redshaw@daimlertruck.com 704-645-5100 Email Address Phone Number