HomeMy WebLinkAbout20121024 Ver 7_Emails_20150513May 5, 2015 N.C. Department of Environment & Natural Resources Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Attention: Roberto Scheller Division of Water Resources Reference: Pipeline Test Water Discharge Report No. 2 —3.1 -Mile Section of Natural Gas Pipeline — Line 42 Pitt /Beaufort Counties, North Carolina S &ME Project No. 1357 -12 -014 NCDWR Project No. 12 -1024 Dear Mr. Scheller: On behalf of Piedmont Natural Gas (PNG), S &ME, Inc. (S &ME) is pleased to submit this sampling report related to a test water discharge event performed for the Line 42 Replacement Project [North Carolina Department of Environment and Natural Resources, Division of Water Resources (DWR) Project No. 12 -1024] located near Washington, North Carolina. BACKGROUND The project involves replacement of an approximately 5.2 -mile section of 10 -inch diameter natural gas transmission line with a new line between Greenville and Washington, North Carolina. The new line was tested in two segments. The first segment (approximately 2.1 miles) was tested and dewatered on April 18, 2015. Results of sampling associated with that dewatering event were provided to DWR by S &ME in an April 21, 2015 report. Following installation of the remaining 3.1 -mile long section of pipe, Appalachian Pipeline Contractors performed the second hydrostatic test and subsequent discharge on May 4, 2015. The hydrostatic test was performed using water pumped from a Tranters Creek (hereafter referred to as the "creek ") adjacent to the pipeline (Figure 1). The quantity of water required for the test was approximately 63,000 gallons. The sampling was performed in accordance with recommendations provided by you to our Joey Lawler during a March 12, 2015 telephone conversation. Results of the May 4, 2015 sampling are provided in this report. S &ME, INC. / 9751 Southern Pine Blvd / Charlotte, NC 28273 / p 704.523.4726 f 704.525.3953 / www.smeinc.com Pipeline Test Water Discharge Report No. 2 May 5, 2015 PNG — Line 42, Greenville, NC S &ME Protect No. 1357 -12 -014 DISCHARGE COLLECTION AREA AND DISCHARGE METHOD Appalachian Pipeline Contractors utilized an approximately 30 -foot diameter dewatering structure constructed in connection with the original dewatering event. The structure was composed of a filter fabric -lined and hay bale- bermed collection area (see Photo Log). The dewatering structure was located in a well- vegetated area approximately 250 feet east of the creek. A 6 -inch diameter pipe was connected to the 10 -inch diameter natural gas pipeline, and terminated within the dewatering structure with a diverter connected at the end of the piping. The 3.1 -mile section of pipeline was "dewatered" by pressurizing the pipeline behind a temporary plug ( "pig ") placed in the pipeline using an air compressor capable of 1,500 cubic feet per minute (cfm). The air pressure was partially controlled using a valve. MAY 4, 2015 DISCHARGE S &ME was on -site during the May 4, 2015 discharge event to test the discharge water along the pathway from the dewatering structure to the stream, located approximately 250 feet away. Also, upstream and downstream locations (Figure 1) were tested prior to and following the discharge on May 4, 2015. S &ME rented two multi- meters from Pine Environmental of Raleigh, North Carolina. The extra set of meters served as a backup in case of equipment failure and as an additional reading in case of exceedances of the surface water quality standards was indicated. The meters were calibrated by Pine Environmental. The results of the testing are discussed below, and the field meter readings and field notes are attached. Photographs of the collection area and discharge during the discharge event are attached. Appalachian Pipeline Contractors discharged approximately 63,000 gallons over a period of approximately 50 minutes (9:10am to 10:00am), at a rate of approximately 1,260 gallons per minute (gpm). Note that due to the permeable soil, the discharge water infiltrated into the underlying soil prior to reaching the creek, thus there was no actual discharge to the creek. Initial and Final Readings of the upstream and downstream creek samples are summarized below. Note that the pre- discharge readings are considered to be "Natural Background," and also considered to be "standard" at the time of discharge. Parameter's Temperature ( °C) Dissolved Oxygen (mg /L) pH (SU) Turbidity (NTU) Published Standard >_5 6 -9 <25 Initial — Upstream 15.27 / 15.40 4.23/4.81 6.33/6.34 0.0/0.0 Initial — Downstream 15.44 / 15.55 4.40/2.37 5.84/6.18 0.0/0.0 Final — Upstream 15.63 / 15.81 4.69/6.48 5.91 /6.48 0.0/0.0 Final - Downstream 1 16.09 / 16.65 4.66/7.13 6.21 /6.01 0.0/2.72 Note: Readings for Field Meter # 1 / Field Meter # 2 Pipeline Test Water Discharge Report No. 2 PNG — Line 42. Greenville. NC May 5, 2015 S &ME Proiect No. 1357 -12 -014 Readings from the sheet flow location (Figure 1) of the discharge water are summarized below. Note, only one round of testing was conducted since the entire event was completed in 50 minutes. Note: Readings for Field Meter # 1 / Field Meter # 2 One of the dissolved oxygen readings of the discharge water was less than 5 mg /L, but as noted above, the discharge water infiltrated into the soil and no discharge water was observed to have reached the stream. CLOSING While one of the two dissolved oxygen readings was less than the "standards ", the test water discharge was not observed entering the stream and the Initial and Final Downstream readings indicate that the pipeline test water discharge did not have a negative impact to the surface water quality. If you have questions concerning this report, please feel free to contact us at your convenience. Sincerely, S &ME Thomas Perez Environmental Technician Senior Review by Al Quarles, L.G. Joey Lawler, P.W.S. Project Manager Attachments: Figure 1 — Site Location Map Photograph Log Meter Calibration Sheets, Field Reports, and Field Reading Sheets Temperature Dissolved Oxygen pH Turbidity Parameter's ( °C) (mg /L) (SU) (NTU) Standard >_5 6 -9 <25 At Sheet Flow 16.72 / 16.81 6.16/4.41 6.51 /6.56 11.1 / 0.0 Note: Readings for Field Meter # 1 / Field Meter # 2 One of the dissolved oxygen readings of the discharge water was less than 5 mg /L, but as noted above, the discharge water infiltrated into the soil and no discharge water was observed to have reached the stream. CLOSING While one of the two dissolved oxygen readings was less than the "standards ", the test water discharge was not observed entering the stream and the Initial and Final Downstream readings indicate that the pipeline test water discharge did not have a negative impact to the surface water quality. If you have questions concerning this report, please feel free to contact us at your convenience. Sincerely, S &ME Thomas Perez Environmental Technician Senior Review by Al Quarles, L.G. Joey Lawler, P.W.S. Project Manager Attachments: Figure 1 — Site Location Map Photograph Log Meter Calibration Sheets, Field Reports, and Field Reading Sheets FIGURE 1 - SITE LOCATION MAP PHOTOGRAPH LOG 15 — Upstream location for dewatering. 15 — Dewatering structure prior to dewatering. — PNG Line 42 — Dewatering 3.1 mile section SWE Project No. 1357 -12 -014 Greenville, North Carolina Taken by: T. Perez Date Taken: 5/4/15 15 - View of low area between stream and dewatering cture after dewatering was completed. Note: water has 1/15 — View of sheet flow from dewatering structure ring dewatering. — PNG Line 42 — Dewatering 3.1 mile section SWE Project No. 1357 -12 -014 Greenville, North Carolina Taken by: T. Perez Date Taken: 5/4/15 METER CALIBRATION SHEETS, FIELD REPORTS, AND FIELD READING SHEETS INSTRUMENT PACKING LIST Description HoribaU -52 and display Instrument ID NJ Headquarters 800 -301 -9663 Date Calibrated ° Standard Items Horiba U -52 w/ ' cable and display w; case - Manual Quick reference card (4) C Alkaline batteries Probe Guard Calibration cup (clear) Sample cup (Black) Flow cell • -Cell body • - Center window • -Base and black bottom • --0 -ring cover - Threaded ring • -(2) black 0 -rings • -(l) red 0-ring • -2 of each barb size (1 4, 318, and 1 /2) D.O. probe reconditioning kit 330 internal pl4 reference solution (1 bottle) 250 ml Autocal solution NISI traceable calibration sheet Prepared by: QC checked by: Date: ` { Prepared f J' f/ t t f QC check I/ Received by Returned to Pine customer This packing list is to ensure that every item needed to operate the unit was sent and received. Upon receiving a shipment please fill out the "Received by customer" eolUmn. Call Pine within 24 hours of receiving the equipment if any pieces are missing, damaged, or malfitnctioning. Thank you far choosing Pine Environmental Services, lne. Pine Environmental Services, Inc. NJ Headquarters 800 -301 -9663 GA 800- 842 -1088 VA 866 -801 -PINE OH 877 -326 -PINE FL 877 - 259 -PINE ME 888- 779 -PINE PA 866- 750 -PINE C'<'IA 800- 519 -PINE TN 877- 355 -7907 ?`ATV 877 - 903 -PINE CA 888- 620 -PINE NC 866 -646 -PINE Canada TX 866- 981 -PINE ON 866 - 688 -0388 CO 866 -960 -PINE BC 877 -678 -8383 Received by Returned to Pine customer This packing list is to ensure that every item needed to operate the unit was sent and received. Upon receiving a shipment please fill out the "Received by customer" eolUmn. Call Pine within 24 hours of receiving the equipment if any pieces are missing, damaged, or malfitnctioning. Thank you far choosing Pine Environmental Services, lne. INSTRUMENT CALIBRATION REPORT Pine Environmental Services, LLC. 8411 Garvey Drive, Suite 113 Raleigh, IBC 27614 Toll -free: (866) 646 -PINE (7463) Pine Environmental Services, Inc. Instrument ID 25335 Description Horiba U -52 Calibrated 5/1 /2015 2:28:47PM Manufacturer Horiba State Certified Model Number U-5000 Status Pass Serial Number/ Lot URU8FGKT Temp °C 21.5 Number Location North Carolina I4untidity % 49.0 Department Calibration Specifications Group # I 0.00 Group Name PH Lft As Stated Accy Pct of Reading 7.00 Nom In Val / In Val In Tvne Out Val Out Type 7.01 0A] i PH 7.01 PH 4.01 114,01 PH 4.01 PH Group # 2 ............. . Group Name Turbidity Lft As Stater] Acey Pct of beading 0.00 Nom In Val / In Val In Type Out Val Out Tic 0.0010.00 NTU 0.00 NTU 800.00 ! 800.00 NTU 800,00 NTU . ... . . . . Group # 3 . . . .. . . . . .... . ... _ ........................... Group Name Conductivity Stated Accy Pct of Reading Nam In Val _/TD Val I_n_ TYRe out Val Out Type 0.718 / 0.718 ms /cm 0.718 ms /cm 5.000 / 5.000 ms /cm 5.000 nis /cm 80.000 / 80.000 tns /cm 80.000 ms /can Group # 4 Group Name Redox (ORP) Stated Acey Pct of Reading None In Val 1 In 17a1 I T Range Ace % 0.0000 Reading; Ace %Q 3.0000 Plus /Minus 0.00 Fnd As Lft As 6.98 7.00 4.10 ............. . _._._ .... .........................._._._ 4.01 Range Ace % 0.0000 Reading Ace %Q 3.0000 Plus /Minus 0.00 Fnd As Lft As 0.00 0.00 788..00 800.00 Range Ace % 0.0000 Reading Ace %a 3.0000 Plus /Minus 0.000 Dcv% Pass /Fail - 0.14 %a Pass 0.00% Pass DMV %fl Pass /Fail 0.00% Pass 0.00% Pass Fnd As Lft As 1)ey %u Pass /Fail 0.712 0.718 0.00% Pass 4.880 5.020 0.40% Pass 78.900 80.100 0,12% Pass Range Ace % 0.0000 Reading Ace % 3.0000 Plus /Minus 0.00 Out Val Out Tvpe Fnd As Lft As Dev% Pass /Fail 240.00 1240.00 MV 240.00 inv o _. _..__ 238.60 240.00 0.00 /o Pass ...._ _ ................. ............... . Group # 5 Range Ace %® 0.0000 Group Name Disolved Oxygen Zero Reading Ace % 3.0000 Stated Acey Pct of Reading Plus /Minus 0.00 Pine Environmental Services, LLC., Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800 - 301 -9663 www.pine-environmental.com pine- environmental.com INSTRUMENT CALIBRATION REPORT Pine Environmental Services, Inc. Instrument ID 25335 Description Horiba U -52 Calibrated 5/1/2015 2:28 :47PM Group # 5 Range Ace % 0.0000 Group Name Disolved Oxygen Zero Reading Ace % 3.0000 Test Standard ID Description Stated Acey Pct of Reading Model Number Plus /Minns 0.00 born In Val f In Val In Type Out Val Ou^:„LhTe Fad As Lft As Dev %o Pass /Fail 0.00/0.00 mg /L 0.00 . ............................... ing/L 0.00 0,00 0.00% Pass Group ## 6 Range Ace % 0.0000 NC 5K COND NC 5K COND Group Name Temperature DO Span. SL 20500 Reading Ace % 0.0000 10 -15 Stated Accy Plus / Minus Plus /]Minus 0.00 NC 718 COND NC COND 718 Norn In Val / In Val In e Out Val Out Type Fnd As Lft As Diey% Pass /Fail 20.00 / 20.00 degrees C 8.84 mg/L 8.84 8.84 0.00% Pass Test Instruments Used During the Calibration (As Of Cal Entry (late) Serial Number / Next Cal Date f Test Standard ID Description Manufacturer Model Number Lot Number Last Cal Date/ Expiration Date Opened Date NC 0 N`i'U 2/16 NC 0 NTU AquaPhoenix SL 30005 C 577492 2/29/2016 Scientific NC 5K COND NC 5K COND Aurical SL 20500 4AJ841 10/31/2015 10 -15 NC 718 COND NC COND 718 AquaPhoenix S1,20718 -HA5G 7/31/2015 7-15 Scientific NC 80 MS /CM NC CONDUCTIVITY AquaPhoenix SL 20032 4AJ839 10/31/2015 COND E P 80 ms/cm Scientific 10 -15 NC ORP 240 NC ORP 240 mV Hanna SL 50005 8154 10/31/2019 10/19 NC PH 4 NC PH 4 AquaPhocnix SL 10007 5AC304 3/31/2017 5AC304 MAR Scientific 17 NC PH10 MAR NC P!I 10 (Lot AquaPhoenix SL 10010 5AC123 3/31/2017 17 1007143) 1.2 -11 Scientific NC PH7 MAR NC PH 7 AquaPhoenix SL 10007 5AC304 3/31/2017 17 Scientific NC TURB NC TURBIDITY Iloriba SL40047- Horiba 2010460 -4 7/31/2016 80ONTU 80ONTU NC; ZERO DO NC ZERO DO 47282746 SODIUM SODIUM SULFITE SULFITE Pine Frivironmental Services, LLC., Windsor Industrial bark, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800- 301 -9563 www.p i ne- environmental, com INSTRUMENT CALIBRATION REPORT Pine Environmental Services, Inc. Instrument ID 25335 Description 1-loriba U -52 Calibrated 5/1/2015 2:28:47PM Notes about this calibration Calibration Result Calibration Successfut Who Calibrated John Paul peon All instruments are calibrated by Pine Environmental Services, LLC. according to the manufacturer's specifications, but it is the customer's responsibility to calibrate and maintain this unit in accordance with the manufacturer's specifications and/or the customer's own specific needs. Notify Pine Environmental Services, LLC. of any defect within 24 hours of receipt of equipment Please call 866 -960 -7463 for Technical Assistance Pine Environmental Services, LLC., Windsor Industrial Park, 92 North Main Street, Bldg 2.6, Windsor, NJ 08561, 800 - 301 -9663 www.pine-environmental.com INSTRUMENT PACKING LIST At [D'esciriPtion Horiba U -52 and display Instrument ID 2 ( � l Date Calibrated Standard Items Horiba U -52 A,/ —' cable and display u/ case Manual Quick reference card (4) C Alkaline batteries Probe Guard Calibration cup (clear) Sample cup (Black) Flow cell • -Cell body • -Center window • -Base and black bottom • -0 -ring cover • - Threaded ring • -(2) black 0- rings • -(I) red 0 -ring • -2 of each barb size (IA, 3/8, and 1/2) D.O. probe reconditioning kit 330 internal pH reference solution (I bottle) 2:50 ml A.utocal solution KIST traceable calibration sheet Prepared by: QC checked by: Date: - Prepared �f QC check Z Received by Returned to Pine customer This packing list is to ensure that ever v item needed to operate the unit was sent and received. Upon receiving a shipment, please.fill out the "Received by customer" column. Call fine within 24 hours of receiving the equipment if any pieces are missing, damaged, or malfunctioning. Thank you for° choosing Pine Environmental Services, Inc. Pine Environmental Services, Inc. NJ Headquarters 800 -301 -9663 GA 804- 842 -1088 VA 866- 801 -PINE OH 877 - 326 -PINE FL 877- 259 -PINE. ME 888- 779 -PINE PA 866 -750 -PINE MA 800 - 519 -PINE TN 877 -355 -7907 Nip 877- 903 -PINK CA 888 -620 -PINE NC 866- 646 -PINE Canada TX 866 - 981 -PINE ON 866 -688 -0388 CO 866 - 960 -PINE BC 877 - 678 -8383 Received by Returned to Pine customer This packing list is to ensure that ever v item needed to operate the unit was sent and received. Upon receiving a shipment, please.fill out the "Received by customer" column. Call fine within 24 hours of receiving the equipment if any pieces are missing, damaged, or malfunctioning. Thank you for° choosing Pine Environmental Services, Inc. INSTRUMENT CALIBRATION REPORT Pine Environmental Services, LLC. 8411 Garvey Drive, Suite 113 Raleigh., NC 27614 Toll -free: (866) 646 -PINE (7463) Pine Environmental Services, Inc. instrument ID 21379 Description Horiba U -52 Calibrated 5/1/2015 2:33:18PM Manufacturer Horiba State Certified Model Number U -5000 Status Pass Serial Number / Lot 18BIXY89 Temp IC 21.6 Number Stated Accy Pct of Reading Dev% Pass /:Pail. Location North Carolina Humidity % 49.0 Department 800,00 ,' 800.00 NTU 800.00 ... ............................... . NTU Calibration_ Specifications Group # 1 Group Name PH Stated Acey Pct of Reading Nom In Val / In Val In -TUC Out Val Out Typ 7.01 / 7.01 PH 7.01 PH 4.01 /4,01 PH 4.01 PH Group # 2 0.00 Group Name Turbidity Fnd As Stated Accy Pct of Reading Dev% Pass /:Pail. Now In 'Val / In Val in TIM e Out Val out `I`Ue 0.00/0,00 NTU 0.00 NTU 800,00 ,' 800.00 NTU 800.00 ... ............................... . NTU Group # 3 0,0000 Group Name Conductivity Reading Ace % Stated Acey Pet of Reading Npm In Val / In Val In Type Out Val Out Tape 0,718 / 0.718 ms/cm 0.719 ms /cm 5.000 / 5.000 ms/cm. 5.000 ins /cm 80.000 / 80.000 ms /cm 80.000 nos /cm Group # 4 Group Name Redox (ORP) Stated Acey Pet of Reading Nom In Val / In Val In Ty0e Out Val Out Type 240 00 i 240 00 Range Ace % 0.0000 Dev% Pass /fail Reading Ace % 3.0000 0.00% Pass Plus /Minus 0.00 0,13% Pass Fnd As Lft As Dev% Pass /:Pail. 6.98 7.00 - 0.14% Pass 4.10 4.01 0.00% Pass Range Ace % 0,0000 Reading Ace % 3.0000 Plus /Minus 0.00 Fnd As Lft As Dev% Pass /fail 0.00 0.00 0.00% Pass 788.00 801.00 0,13% Pass Range Ace % 0.0000 3.0000 Reading Ace % 3.0000 Plus /Minus 0.000 Fnd As Lft As 0.713 0.718 4.860 5.010 78.500 80,100 Range Ace % 0.0000 Reading Ace % 3.0000 Plus /Minus 0.00 Dev% Pass /Fail 0.00% Pass 0.20% Pass 0.12% Pass Fnd As Lft As Dev% Pass /Fail my 240.00 My 238.50 240.00 0.00% Pass Group # 5 Group Name Disolved Oxygen Zero Stated Acey Pet of Reading Range Ace % 0.0000 Reading Ace % 3.0000 Plus /Minus 0,00 Pine Environmental Services, LLC., Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800 - 301 -9663 www,pine4environmental.corn INSTRUMENT CALIBRATION REPORT Pine Environmental Services, Inc. Instrument ID 21379 Description Horiba U -52 Calibrated 51112015 2.33:18PM Group # 5 Description Range Ace % 0.0000 NC 0 NTU AquaPhoenix Group Name Disolved Oxygen Zero NC PIi 4 Reading Ace % 3.0000 NC 5K COND Aurical Stated Accy Pct of Reading C 577492 Plus /Minus 0.00 NC COND 718 AquaPhoenix Nom In Val / In `7al In I`yp Out Val Out Tyne Fnd As Lft As Dev% Pass /fail 0.00 ; 0.00 mg /L 0.00 nag /L 0.00 0.00 0.00 % Pass Group # 6 80ONTU Range Ace % 0.0000 NC ZERO DO 3/31/2017 Group Name Temperature DO Span SODIUM SULFITE Reading Ace % 0.0000 Stated Accy Pius / Minus Plus /Minus 0.00 Nora In Val / In Val In Tyree Out Val Out Type Fud As Lft As Devi% Pass /Fall 20.00 / 20.00 degrees C 8.84 nig /L 8.84 8.84 0.00% Pass Test Instruments Used During the Calibration Test Standard ID Description Manufacturer NC 0 NTU 2/16 NC 0 NTU AquaPhoenix NC PH 4 NC PIi 4 Scientific NC 5K COND NC 5K COND Aurical 10 -15 C 577492 2/29/2016 NC 718 COND NC COND 718 AquaPhoenix 7 -15 1007143) 12 -11 Scientific NC 80 MS,'CM NC CONDUCTIVIT`i' AquaPhoenix COND EXP 80 ms /cm Scientific 10 -15 NC ORP 240 NC ORP 240 mV Hanna 10/19 Serial Number I Next Cal Date l NC PH 4 NC PIi 4 AquaPhoenix 5AC304 MAIL Scientific 17 C 577492 2/29/2016 NC PHIO MAR NC PH 10 (Lot AquaPhoenix 17 1007143) 12 -11 Scientific NC PH7 MAR NC PH 7 AquaPhoenix 17 8154 Scientific NC TURK NC TURBIDITY Horiba 800NTU 80ONTU 3/31/2017 I NC ZERO DO NC ZERO DO 3/31/2017 SODIUM SODIUM SULFITE 7/31/2016 SULFITE 47282746 Pine Environmental Services, LLC., Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800 -301-9663 www. pine- environmental.com A( s Of Cal Entry Date) Serial Number I Next Cal Date l Model Number Lot Number Last Cal Date/ Exgiratiou Date Opened Date SL 30005 C 577492 2/29/2016 SL 20500 4AJ841 10/32/2015 SL20718 -HA5G 7/31/2015 SL 20032 4AJ839 10/31/2015 SL 50005 8154 10/31/2019 SL 10007 5AC304 3/31/2017 SL 10010 5AC123 3/31/2017 SL 10007 5AC304 3/31/2017 SL40047- Horiba 2010460 -4 7/31/2016 47282746 Pine Environmental Services, LLC., Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800 -301-9663 www. pine- environmental.com INSTRUMENT CALIBRATION REPORT Pine Environmental Services, LLC. 8411 Garvey Drive, Suite 113 Raleigh, NC 27614 Toll-free: (866) 646-PINE (7463) Pine Environmental Services, Inc. instrument ID 21379 Description Horiba U-52 Calibrated 5/1/2015 2:33:18PM Notes about this calibration Calibration Result Calibration Successful Who Calibrated John Paul Keon All instruments are calibrated by Pine Environmental Services, LLC. according to the manufacturer's specifications, but it is the customer's responsibility to calibrate and maintain this unit in accordance with the manufacturer's specifications and/or the customer's own specific needs, Notify Pine Environmental Services, LLC. of any defect within 24 hours of receipt of equipment Please call 866-960-7463 for Technical Assistance Pine Environmental Services, LLC,, Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800-301-9663 W Vw.pinc-cnvironmental.com s:11354imanagement\FIELDLOG.XLS Revised 4 /18/01 -02-'�� 3 PNG Line 42 Replacement w� Hydrostatic Test Water Discharge Monitoring S&ME Project No, 1357-12-014 42, Signature: -f U r7-e4� Date: 51 'q/ Date: S&ME Personnnel: PC- Time Temp I Tem?- DO #1 DO #2 pH #1 pH #2 Turbidity #1 Turbidity #2 Notes; o C o C (m /L) (m IL) (SU) (SU) (NTU) (NTU) Standard ?5 ?5 6-9 6-9 525 525 14 0, & 13 kf Signature: -f U r7-e4� Date: 51 'q/