HomeMy WebLinkAboutNCC231228_Site Plan or Location Map_20230426 CONSTRUCTION DRAWINGS FOR 2 6 g
OJN
Va
p0
KNIGHTDALE STATION l7 V
zZw
8,p
03
R8 INDEX OF SHEETS
Sheet Number Sheet Title
1.0 OVERALL EXISTING CONDITIONS
1.1 EXISTING CONDITIONS
2.0 OVERALL SUBDIVISION PLAN
KNIGHTDALE, WAKE COUNTY, NORTH CAROLINA 3.23.1 SITE PLA
PAVEMENT MARKINGS&N310NAOE PLAN
SITE DATA TABLE - PHASE R8 4.1 UTILITY PLAN
JANUARY 18, 2022 5.1 STORM DRAINAGE-PLAN
KNIGHTDALE PROJECT No. S-3-13-R8 5.2 STORM DRAINAGE SCI IEDULES
OWNER KNIGHTDALE INVESTORS, LLC.
PARCEL PIN No. 1764065984 5.3 GRADING PLAN
EXISTING ZONING GR8
PROPOSED ZONING GR8 ;; 6.1 PRE-EROSION CONTROL PLAN
PROPOSED USE SINGLE FAMILY I
TOTAL PHASE AREA 1 6.37 AC I `" 6.2 POST EROSION CONTROL PLAN
RECREATIONAL OPEN SPACE (ACTIVE) 0.00 AC I
RECREATIONAL OPEN SPACE (PASSIVE) 0.92 AC II ---------_ 1 7.1 NAUGATUCK DRIVE PLAN AND PROFILE
TOTAL OPEN SPACE 0.92 AC --- I - Vic% _--- ,
MAXIMUM DENSITY ALLOWED (UNITS/ACRE) 12 ^- I !7'%'':'""'"T -"q'--.: _
p �,- ? 7.2 LOCOMOTIVE RUN PLAN AND PROFILE
PROPOSED DENSITY (UNITS/ACRE) 2.38 I I i�
TOTAL NUMBER OF LOTS ALLOWED N/A I'1-__, It av+J"��i---
-'%' I ' `
TOTAL NUMBER OF LOTS PROVIDED 39 I ewo°s I L' I 7.3 FLAT CAR LANE&SANITARY SEWER OUTFALL M PLAN AND PROFILE
TOTAL LINEAR FEET IN STREETS (PUBLIC) 2,217 LF ` I � o /% ,\ i'1_
TOTAL LINEAR FEET OF CURB & GUTTER (30") 4,338 LF I aN :.!: 6.0 GCM 11 PLAN&DETAILS
TOTAL LINEAR FEET OF SIDEWALK 4,223 LF \ '� ILINEAR FEET IN WATERLINES (6 IN) 107 LF I I ' FUTURE I • 0.1 SCM DETAILS
LINEAR FEET IN WATERLINES (8 IN) 2,295 LFMU-5LINEAR FEET IN WATERLINES (12 IN) 0 LF I � , .. 9.1 ROADWAY DETAILS
TOTAL LINEAR FEET IN STORM DRAINAGE 2,603 LF \`.,
TOTAL LINEAR FEET IN SEWER LINES (8 IN) 2,235 LF s\ %., '7�"� i PUMP -� 9.2 STORM DRAINAGE DETAILS
PROJECTED WATER USAGE (GPD) 9,750 I;I I >:,%' �
(25o GPD/UNIT) i II ���\ �;;'' - `,•i, I>\11 ` ,,,,ii.•STATION % g,3 EROSION CONTROL DETAILS
PROJECTED SEWER USAGE (GPD) 9,750 I ' - \\��♦-- // //
•
(250 GPD/UNIT) `�-_--1___ I �\ \ �� A__- / w\= 11 (' /. _
/, o Q /l-i(;7 ,• _ 9.1 WATER UTILITY DETAILS
CD �"`'`' " � /� •i 9.5 SEWER UTILITY DETAILS
LOTS 573-611 I I e s c?f9
t7/�`,','�f::. ��/ +� - / 9.6NCDEQ NCG01 DETAIL
MINIMUM LOT WIDTH REQUIRED 60 LF --'I ' ''�'.`5" `` i ® --,..-:-`���--., ,,,, ,,%='_____"" -�./ - 4-----
LOT WIDTH (TYP.) 60 LF �'- `. rf J_o _ S/ ' _tom. �.._-%/- - I L1.0 LANDSCAPE PLAN
/�
MINIMUM LOT AREA PROVIDED 7,198 SF 1 ,,,' f~ �\ �/ -s r-i l'j % A' ;___J
Aso-
MEDIAN LOT AREA PROVIDED 7,892 SF '' ��;;' of� f��` '. FUTURE i L1.1 LANDSCAPE DETAILS
AVERAGE LOT AREA PROVIDED 8,376 SF NFUlURE 4;'/- _, l �� ��11 e�,t{�,�� � R7N
MU-3 �� �1�� I 1�� -- �i�'I�R6D
LOT SETBACKS ' ''�� =C �����l�� /,`-' ;1)
: \
f'' I ��� ' WI x� EROSION CONTROL STORMWATER
FRONT YARD 10 FT 1 j �� 1
REAR YARD 25 FT R4 11111 _ ` `
ii, / �`�'� / / ��r 11111111111�1 1111 AND FLOODPLAIN MANAGEMENT
SIDE YARD 20% OF LOT WIDTH (AGGREGATE) 1 '. ,'
-5 FT MIN. SETBACK PER SIDEi ♦ .,'
(WIDTH 60' OR GREATER) .`�,%�� ♦\ / ♦ �/'' �//I �"A1 111 ..■ Ill )‘_,
' APPROVED
3 FT MIN. SETBACK PER SIDE s '/,:-, \� v <�\ _SiI
(WIDTH LESS THAN 60') �� �\ �\� ' I�1,�.`I \ „'�
REAR SETBACK FROM LANE/ALLEY 15 FT FROM CENTERLINE /���� ,� /� ) �\71`....-
, ,�1 """ '' I7�- Cl/ , EROSION CONTROL ❑ .-
ACCESSORY STRUCTURE SIDE/REAR SETBACK 5 FT FU`fURE ♦ //MU 2 ✓� ♦ ���H� ���� � �� / i -J�. �' ,7 �„ a � �♦��� �,�j\r1i ,� /�, STORMWATER MGMT.❑ S-
.PER UDO SECTION 4.6(C)(3),ACCESSORY BUILDINGS SHALL BE A MINIMUM ll 6® S� 'Pil•S*. �v)4 lig / ,,,'•\;,,,,,'' 1- � -_$' FLOOD STUDY❑S-
OF 5'FROM ANY PRINCIPAL BUILDING OR OTHER ACCESSORY BUILDING. '^\ �iE��/J`Vss, � i u {//_/ ,11
**PER UDO SECTION 4.6(C),ACCESSORY BUILDINGS SHALL NOT EXCEED 800 SF; - j ``3C /' it Mill „ ' ,, 01 Fg'-- �/ --, DATE
COLLECTIVELY COVER MORE THAN 20%OF THE TOTAL COMBINED AREA OF THE ' // /' j , I
LOTS'REAR AND SIDE YARDS; INDIVIDUALLY EXCEED THE HEIGHT OF THE ♦ / i �/
PRINCIPAL BUILDING. �- II �` MU 1 • I"' --- III ",,,'', ,, R8 / / /-/
***DRIVEWAY LENGTH FROM GARAGE TO EDGE OF ASPHALT SHALL BE A I SRO Nxdr / 1 ATTENTION CONTRACTORSgl
MINIMUM OF 20'ALONG ALLEYS. �' r / �l//I I ' -"/ \\\J� ENVIRONMENTAL CONSULTANT SIGNATURE
L-J
\� ,,,' - / THE CONSTRUCTION CONTRACTOR RESPONSIBLE FOR THE EXTENSION OF WATER
___ / 1 AND SEWER,AS APPROVED IN THESE PLANS,IS RESPONSIBLE FOR CONTACTING
1�� / 1 1 THE PUBLIC()PUBES DEPARTMENT AT 1919)996-4540 AT I FAST 24 HOURS
�/��, / , y` ' �_ PRIOR TO BEGINNING ANY CONSTRUCTION. TOWN CERTIFICATION.THIS DESIGN HAS BEEN REVIEWED BY THE
ENGINEER FOR THE TOWN OF KNIGHTDALE,AND TO THE BEST OF
1 J IN I "- ✓ I FAILURE TO NOTIFY BOTH CITY DEPARTMENTS IN ADVANCE OF BEGINNING MY KNOWLEDGE AND BELIEF,IT CONFORMS TO THE REQUIREMENTS
_ - ,( CONSTRUCTION WILL RESULT IN THE ISSUANCE OF MONETARY FINES AND ESTABLISHED IN THE STANDARD SPECIFICATIONS OF THE TOWN OF
j E _ ` KNIGHTDALE.
REQUIRE REINSTALLATION OF ANY WATER OR SEWER FACILITIES NOT INSPECTED
`-I = 1 r./j�a � \Li-
``"\ ,Y. AS A RESULT OF THIS NOTIFICATION FAILURE BY: DATE:
INFRASTRUCTUREDATA J L ��� I FAILURE TO CALL FOR INSPECTION INSTALL A DOWNSTREAM PLUG,HAVE DEVELOPMENT SERVICES ENGINEER
j I 1 - I PERMITTED PLANS ON THE JOB SITE,OR ANY OTHER VIOLATION OF CITY OF RALEIGH THESE PLANS ARE APPROVED BY THE TOWN OF KNIGHTDALE AND
n, f� I I I IF fff 1 1 STANDARDS WILL RESULT IN A FINE AND POSSIBLE EXCLUSION FROM FUTURE WORK SERVE AS CONSTRUCTION PLANS FOR THIS PROJECT.
r SECTIONS AREA UNITS STREETS 30" CURB & SIDEWALK 6" WATER 8" WATER 12" WATER STORM 8" SEWER SEWER FLOW .1, 1 ,� --�- IN THE CITY OF RALEIGH. BY: DATE:
[AC] [LE] GUTTER[LF] ELF] MAIN [LT] MAIN ELF] MAIN ELF] DRAINAGE ELF] MAIN ELF] [GPO] II TL--------P ADMINISTRATOR
I ' III
PHASE R8 16.37 39 2,217 4,338 4,223 107 2,295 - 2,603 2,235 9,750 I --J
T __i
it
Ilr��_-I L TOWN APPROVED STANDARDS SHALL CONTROL.IN THE EVENT
H-1-
OF A CONFLICT OR INCONSISTENCY BETWEEN THESE
V I C I N I TY MAP 1"=500' CONSTRUCTION DRAWINGS AND THE TOWN OF KNIGHTDALE'S
APPROVED STANDARDS FOR THIS PROJECT,THE APPROVED
STANDARDS SHALL CONTROL.TOWN OF KNIGHTDALE APPROVED
STANDARDS SHALL MEAN ALL DEVELOPMENT DOCUMENTS
NECESSARY FOR APPROVAL FOR THE PROPERTY INCLUDING,BUT
NOT LIMITED TO,ANY SPECIAL USE PERMIT,SUBDIVISION PLAN,
SITE PLAN,SUBDIVISION(S),PHASING SCHEDULE,
ffi DEVELOPMENT AGREEMENT,UTILITY ALLOCATION AGREEMENT
ANNEXATION AGREEMENT,THE TOWN OF KNIGHTDALE
DEVELOPER/OWNER PREPARED BY: STANDARDPLICABSPECIFICATIONON AND DETAILS MANUAL AND
APPLICABLE PROVISIONS OF THE NORTH CAROLINA STATE
BUILDING CODE.
DFC KNIGHTDALE STATION LLC PROFESSIONALE TRUCN INENGINEER CERTIFICATION.IT THESE IMPROVEMENTS
SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING
DRAWINGS AND WITH THE STANDARD SPECIFICATIONS OF THE TOWN OF
KNIGHTDALE.I,COLT EEN F.DIIRFFA PF,CERTIFY THAT THE STANDARD
14701 PHILIPS HWY 1/ CHECSPECKED ANNDS OF THE FOUND TO BE APPLICABLETO ETHISHAVE
PROJECT.ALTHOROUGHLY
p SUITE 300 W i t h e rs Ra ve n e l PREVIOUSLY TO THE APPLICABLE EE TOWN STANDARDS HAVE BEEN
PREVIOUSLY APPROVED BY THE TOWN OF KNIGHTDALE AND SAID
1/ EXCEPTIONS ARE SHOWN ON SHEET(S) OF THESE
JACKSONVILLE,FL 32256 DRAWINGS.
Engineers I Planners Surveyors °°tNOARoN,,
ATTN:JUSTIN HEATON 115 MacKenan Drive I Cary,NC 27511 I t:919.469.3340 I license#:F-1479 I www.withersravenel.com ,pp„� p ate o a� SEAL�'°°
_ TELEPHONE:(732)644-0555 BY: �E„E" p .PE G49345
1/19/2022 O"°c'frG I NE ****
DATE: o