Loading...
HomeMy WebLinkAboutWQ0000088_Monitoring - 03-2023_20230418Monitoring Report Submittal ..................................................... Permit Number#* WQ0000088 Name of Facility:* Month: * March Report Information Governors Club WWTP Year:* 2023 Type* Upload Document* NDMR, NDAR-1, NDAR-2, NDMLR Governors Club March 2023 NDMR.pdf 69.22KB PDF Only NDMR, NDAR-1, NDAR-2, NDMLR Governors Club March 2023 NDAR.pdf 944.61KB PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). Confirmation Email Address: * RdLyons@aquaamerica.com Name of Submitter: * Roy Lyons Signature: Date of submittal: 4/18/2023 This will be filled in automatically Initial Review Reviewer: Wanda.Gerald Is the project number correct?* WQ0000088 Is the monitoring report accepted?* Yes No Regional Office* Raleigh Reviewer: _anonymous Review Date: 4/25/2023 Permit No.: W00000088 Facility Name: Governors Club WWTP County: Chatham Month: March Year: 2023 PPI: 001 Flow Measuring Point: ❑ influent ❑ Effluent ❑ No flow generated Parameter Monitoring Point: ❑ Influent M Effluent ❑ Groundwater Lowenng ❑ Surface water Parameter Code -ep. 50050 00310 00940 50060 31616 00610 00625 00620 00600 00400 00665 70300 00630 00076 0cc 7 0 c Q n cc O m c Q s m o� o � 0 Lt`o o� c € �E cy t � A [o - z zo a 2 o 0. a 2! -0 o$ o (1) e v r - oO 0 ( m a~T 24-hr hrs GPD mg/L mg/L mg/L Vl00 rnL mg/L mgA. mg/L mg1L su mg/L mg/L mg/L NTU 1 800 4 108,255 2 90 3.1 <1.0 <.10 1.3 48 49.3 7.1 5.9 610 <2.5 0.1 2 800 4 121.802 2.3 7.2 0.1 3 800 4 108,154 1.5 7.1 0.1 4 100,133 0.1 5 112,070 0.1 6 800 1 4.5 96,081 0.8 7.1 0.1 7 800 4 107,102 0.7 7.2 0.1 8 B00 4 95,427 0.8 7 0.4 9 800 4 106,121 0.9 7 0.3 10 800 4 92,415 0.6 7.1 0.2 11 94,384 0.3 12 1 102,469 0.3 13 800 4.5 104,489 0.7 7.2 0.3 14 800 4.5 106,043 1 1.1 7.3 0.3 15 800 4 93,268 2.2 2.6 <1.0 <.10 <.10 98 98.1 Ti 4.8 <2.5 0.5 16 800 4 100,107 1.3 7.3 0.2 17 800 4 108,489 0.9 7 0.2 18 1 96,359 0.4 19 95,340 0.4 20 800 4 93,185 1 1.2 7.1 0.4 21 800 4 101,672 1.4 7.2 0.5 22 800 4.5 88,676 1.4 7.1 0.4 23 800 4.5 102,280 1.2 7.2 0.3 24 800 4.5 109,962 1 7.2 0.3 25 107.738 0.1 26 116,933 1 0.1 27 800 4 102.597 1.2 7.4 0.1 28 800 4 108,551 1.3 7.2 0.5 29 800 4.5 91,011 1.3 7.3 0.2 30 800 4 76,867 1.3 7.2 0.2 311 800 1 4 112,773 1.2 7.4 0.3 Average: 101,9W 2.10 90.00 1.30 1.00 0.00 0.65 73.00 73.70 5.35 610.00 0.00 0.25 Daily Maximum: 121,802 2.20 90.00 3.10 1.00 0.10 1.30 98.00 98.10 7.40 5.90 610.00 2.50 0.50 Daily Minimum: 76,867 2.00 90.00 0.60 1.00 0.10 0.10 48.00 49.30 7.00 4.80 610.00 2.50 0.10 Sampling Type: Recorder Composite Composite Grab Grab Composite Composite Composite Composite Grab Composite Composite Composite Recorder Monthly Avg. Limit: 234,128 10 14 4 5 Daily Limit: 15 25 6 10 10 Sample Frequency. Condnuous 2 X Month 3 X Year 5XWeekj2XMonlhj 2 X Month 2 X Month 2 X Month 2XMonthj5XWeekj2XMonthj 3 X Year 2 X Month Continuous Sampling Person(s) Certified Laboratories Name: Roy Lyons Name: Enco 591/ Eurofins 269 Name: 11 Name: Aqua 5051 Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? a compliant CI Non-Coml If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the cc action(s) taken. Attach additional sheets if necessary. IOperator in Responsible Charge (ORC) Certification Permittee Certification ORC: Roy Lyons Certification No.: 1005944 Grade: IV Phone Number: 919-323-1213 Has the ORC changed since the previous NDMR? 0 Yes is No Signature Date By this signature, certify that this report 4s accurrate and complete to the best of my knowledge. Permittee: Aqua North Carolina Signing Official: Katie Dickens Signing Official's Title: Field Supervisor 2 Phone Number: 910-695-5846 Permit Expiration: 7/31/202: T L Signature Dz I certify, under penalty of law, that this document and all attachments were prepared under my direction or super accordance with a system designed to assure that all qualified personnel property gathered and evaluated the informal Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gi information, the information submitted is, to the best of my krrovAedge and belief, true, accurate, and complete. I an there are significant penalties for submitting false information, including the possibility of tines and imprisonment tc violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit