HomeMy WebLinkAboutWQ0001664_Correspondence_20230412WN Carolina Water Service of North Carolina - April 12, 2023 Morelia Sanchez -King, Regional Supervisor Water Quality Regional Operations Section Wilmington Reginal Office Division of Water Resources, NCDEQ Subject: Belvedere Plantation WWTP 03/24/2023 Compliance Inspection Inspection Report Items 1 — 3 Dear Ms. Morelia Sanchez -King, On behalf of Carolina Water Service, Inc. of NC (CWSNC), please accept this letter in response to the Belvedere Plantation Compliance Inspection Report, items 1-3. The groundwater lowering system discharging to the wetland feature was observed during the inspection by Geoff Kegley. Some of the flow from the groundwater lowering system seeps back toward infiltration basin A. CWSNC further investigated the issue and discovered mature trees were growing in front of the effluent discharge pipe. Those trees have been removed and flow is now being distributed towards the wetlands. 2. Corrosion/rust was observed on the inside of EQ basin and should be repaired, per Geoff Kegley. CWSNC has contacted a professional company that specializes in metal rehabilitation work to assess the corrosion/rust on the inside of the EQ basin. Necessary repairs will be made, which may include sand blasting, priming, and painting, of the area where corrosion/rust was observed. P.O. Box 240908 • Charlotte, North Carolina 28224-0908 (800) 525-7990 • cwsnc@carolinawatemervicenc.com •www.carolinawaterservicenc.com MCarolina Water Service of North Carolina" Monitoring wells MW — 7 through MW —10 should be permanently abandoned, per permit schedule I.1. CWSNC has contacted Applied Resource Management, a certified well drilling contractor in the State of North Carolina. Applied Resource Management conducted a site visit of the monitoring wells on 04/11/2023 and provided a proposal to permanently abandon monitoring wells MW — 7 through MW —10. The proposal has been accepted by CWSNC. We are anticipating Applied Resource Management will have the abandonment of MW — 7 through MW —10 completed within the next 30 days. We will continue to keep NCDEQ updated on the status of inspection report items 1 — 3. If you need additional information, please feel free to contact me at 312-965- 3728, or by email at anthonv.futrell@carolinawaterservicenc.com Sincerely, G� Anthony Futrell Area Manager CC: Geoff Kegley, Environmental Program Consultant Greg Spillman, Operator in Responsible Charge Brent Milliron, Regulator Compliance Manager Tony Konsul, Director, State Operations P.O. Box 240908 • Charlotte, North Carolina 28224-0908 (800) 525-7990 • msnc@carolinawatersewicenc.com • www.carolinawaterservicenacom