Loading...
HomeMy WebLinkAboutNC0026441_Pretreatment_IUP_Additional_Information_Request_20230421DocuSign Envelope ID: C7CC3F62-825E-4E2E-9FAF-5FA1D18A27F1 ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director NORTH CAROLINA Environmental Quality 4/21/2023 Via Electronic Mail (cmccorquodalegsilerci , .or ) Mr. Chris McCorquodale Director of Public Works & Utilities Town of Siler City P.O. Box 769 Siler City, NC 27344 Subject: Pretreatment Review of Industrial User Pretreatment Permit Draft Renewal Program: Town of Siler City Wastewater Treatment Plant: Town of Siler City WWTP NPDES #: NC0026441, Chatham County Dear Mr. McCorquodale: The Municipal Unit of the Division of Water Resources has reviewed the Industrial User Pretreatment Permits (IUP) draft renewals submitted by the Town of Siler City for the following Significant Industrial Users (SIUs). The first drafts of these ]UPS were received by the Division on December 1st, 2022. IUP # SIU NAME 003 Brookwood Farms, Inc. 004 Mountaire Farms Inc. 005 Town of Siler City Water Treatment Plant The Division requests the following changes and additional information to the submitted draft LUPs. In reference to Siler City's NPDES permit the Division will expect a quarterly report on the construction status for SIUs with compliance schedules (see our comments below). This condition aims to confirm that the limits proposed in the permit drafts are sufficient to comply with the issued Special Order of Consent (SOC). All IUPs — • Include engineering calculations for the derived IUP limits of BOD5, Total Nitrogen, and Total Phosphorus. The engineering calculations must include all SIU aggregate contributions for each pollutant listed above. This will verify that Siler City can meet the final nutrient limits after their compliance schedule with the identified final SIU limits. In addition, please insure that each SIU's compliance schedule aligns with the issued NPDES permit. • A separate units column should be added to the draft permit's "Effluent Limits and Monitoring Requirements" table located in Part I, F. Some values are mg/l, pH is Standard Units, 1,4 dioxane and PFAS compounds are ug/1 and ng/1 respectively. • Please specify a detection limit of 1 µg/l for 1,4, Dioxane as a footnote to the table in Part I, F. And follow EPA's guidance on detection for PFAS compounds. • In the table in Part I, F, footnotes 2 and 4 refer to special conditions No. 6 and No. 7, please include the part/section of the permit where the special conditions are located, for example, "Part 111, Special Condition 6". North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 1 1611 Mail Service Center I Raleigh, North Carolina 27699-1611 NORTH CARCLINA 919.707.9000 DocuSign Envelope ID: C7CC3F62-825E-4E2E-9FAF-5FA1D18A27F1 Mountaire Farms Inc. (IUP# 004) — Include a full-size scan of the site map in Part I, E. The full- size scan will be included as a supplemental document to the permit. Additionally, the sample location must be clearly marked on the supplemental site map. The SIU will be required to supply a quarterly report detailing the progress with the compliance schedule stated in Part III (8) of the IUP. Additional language in the IUP is required to be added to Part III (8) to comply with the quarterly report. Town of Siler City Water Treatment Plant (IUP# 005) — Include a site schematic and site map to Part I, E of the IUP. The site map must include a clear location for the sample location [so that a person not familiar with the site can easily find the sample location]. A site map like the one found in Brookwood's IUP will be sufficient to fulfill this request. Provide further information on how monitoring duties will be allocated between the SIU and the POTW. The "Monitoring Frequency" column in Part I, F should be changed from "Town" to "POTW" and "Permittee" to "SIU". Since the "Town" as an entity can be interpreted as both the Permittee and Control Authority. The Water Plant SIU will be required to supply a quarterly report detailing the progress with the compliance schedule stated in Part III (8) of the IUP. Additional language in the IUP is required to be added to Part III (8) to comply with the quarterly report. The Division requests this information to be provided within fifteen days. This completes all pending comments on these draft IUP's. If you have any questions or comments, please contact Keyes McGee at (919) 707-3626 [email: keyes.mcgee@ncdenr.gov] or Octavio Henriquez at (919) 707-3662 [email: octavio.henriqueznncdenr. og_v] Thank you for your continued support of the Pretreatment Program. Sincerely �AD•o'c'u.Siigneld by: A `,• �'w.'' ` IVU&Ad khKit �I h C464531431644FE... Michael Montebello, Section Chief NPDES Permit Branch Division of Water Resources oih/slc_silercity_iup_review Ec: Municipal Unit File Cheng Zhang, RRO Central Files (Laserfiche) REQ5 North Carolina Department ofEnvironmental Quality I Division ofWater Resources 512 North Salisbury Street 1 1611 Mail Service Center I Raleigh, North Carolina 27699-1611 NORTH CAROLINA 919.707.9000 onparhnem of EmironmanW 9uallly