Loading...
HomeMy WebLinkAbout20050732 Ver 31_Site Plan_20150508Strickland, Bev From: Gareth Avant <GAvant @mckimcreed.com> Sent: Friday, May 08, 2015 8:36 AM To: Strickland, Bev Cc: Ben Smith Subject: RE: Briar Chapel - Boulder Point Extension DWQ# 050732 Ver 31 Bev, As these files are a little large, I have provided a link for you to download these documents. httos:// www. sendthisfile .com /iwio3aFAnAlaDo9EDGhuFiG9 From: Strickland, Bev [ mai Ito: bev.stricklandCa)ncdenr.govI Sent: Wednesday, May 06, 2015 3:18 PM To: Gareth Avant Subject: Briar Chapel - Boulder Point Extension DWQ# 050732 Ver 31 Mr. Gareth, Could you please send me the storm water plan large maps electronic, including the Flood Insurance map? My large scanner is down. Thanks Bev Beve�dy Storlicllldarmd, Laseorfiidl me AdrrflrflstraU)r NCDENR - Division of Water Resources Physical: Suite 1219, 512 N Salisbury, NC Mailing: Mail Service Center 1617, Raleigh, NC 27699 -1617 Phone# 919 - 707 -8789 Email Address: Bev.Strickland @ncdenr.gov This e -mail and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this e -mail in error please notify the system manager. Please note that any views or opinions presented in this e -mail are solely those of the author and do not necessarily represent those of the company. Finally, the recipient should check this e -mail and any attachments for the presence of viruses. The company 1 accepts no liability for any damage caused by any virus transmitted by this e -mail. BOULDER POINT DRIVE EXTENSION CONSTRUCTION DOCUMENTS U.S. HWY 15 -501 and MANN'S CHAPEL ROAD COUNTY AND AGENCY CONTACTS A. Chatham County Planning Department Dunlap Building 80 East Street Pittsboro, NC 27312 (919) 542 -8204 phone Contact: Jason Sullivan Email: jason.sullivan @chathamnc.org B. Chatham County Environmental Services Dunlap Building 80 East Street Pittsboro, NC 27312 (919) 542 -0945 phone Contact: Dan LaMontagne, PE Email: dan.lamontagne @chathamnc.org C. Chatham County Soil Erosion and Sedimentation Control Dunlap Building 80 East Street Pittsboro, NC 27312 (919) 545 -8339 phone Contact: Rachael Thorn Email: rachael.thorn @chathamnc.org D. Chatham County Public Works 964 East Street, 2nd Floor, Suite 205 Pittsboro, NC 27312 (919) 545 -8530 phone Contact: Larry Bridges Email: larry.bridges@chathamnc.org E. NCDOT Division 8, District 1 300 DOT Drive P.O. Box 1164 Asheboro, NC 27204 (336) 318 -4000 phone Contact: Jeff B. Loflin, PE Email: jloflin @ncdot.gov F. NCDENR Division of Water Quality 512 N. Salisbury St Archdale Building, 9th Floor Raleigh, NC 27604 (919) 807 -6373 phone Contact: Boyd Devane Email: boyd.devane @ncdenr.gov G. NCDENR Division of Environmental Health Public Water Supply Section 1634 Mail Service Center Raleigh, NC 27699 -1634 (919) 707 -9074 phone Contact: Richard Dickie Email: richard.dickie @ncdenr.gov H. NCDENR Division of Water Quality Surface Water Protection 3800 Barrett Drive Raleigh, NC 27609 (919) 791 -4200 phone Contact: Danny Smith Email: danny.smith @ncdenr.gov CHATHAM C NORTH CAROLINA DATE: APRIL 17, 2015 4 '006 Nhh' 0 1/ MANN'S CHAPEL RD TO CHAPEL HILL NORTH III O GREAT RIDGE LO PKWY V_ l C q�PEL PKWY BOULDER 'ter BRIAR SITE POINT DR L -- CHAPEL r — �� � PKWY AiypRewS STOR _ -- RO i VENTY MAP NOT TO SCALE � TO PITTSBORO Fa n.n. • by Newland COMMUNITIES VICINITY MAP NTS PROJECT DATA NAME OF PROJECT: BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA OWNER: NNP BRIAR CHAPEL, LLC 16 WINDY KNOLL CIRCLE CHAPEL HILL, NC 27516 PHONE: (919) 951 -0700 FAX: (919) 240 -4963 CONTACT: LEE BOWMAN EMAIL: Ibowman @newlandco.com MYO McKIM & CREED 1730 VARSITY DRIVE, SUITE 500 RALEIGH, NORTH CAROLINA 27606 PHONE: (919) 233 -8091 FAX: (919) 233 -8031 CONTACT: GARETH AVANT, PE EMAIL: gavant @mckimcreed.com PROJECT AREA: 3.59 ACRES These improvements shall be constructed in accordance with the following plans, and the Standard Specifications of NCDOT and Chatham County. NFI<M&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233 -8091, Fax (919)233 -8031 F -1222 www.mckimcreed.com SHEET INDEX CO.1 COVER SHEET C0.2 EXISTING CONDITIONS /DEMOLITION PLAN C1.1 SITE PLAN C2.1 UTILITY PLAN C3.1 STAGE 1 EROSION CONTROL PLAN C3.2 STAGE 2 GRADING, DRAINAGE & EROSION CONTROL PLAN C4.1 PLAN & PROFILE BOULDER POINT EXTENSION D1.1 DETAILS — EROSION AND SEDIMENTATION CONTROL D1.2 DETAILS — EROSION AND SEDIMENTATION CONTROL D2.1 DETAILS —NCDOT DRAINAGE D2.2 DETAILS — ROADWAY TYPICAL SECTIONS D2.3 DETAILS — GUARDRAIL DETAILS D3.1 BMP #20 DETAILS �. Q�pFESS /0H9 ?q , AL 036348 G� • 04/17/2015 %q�• FNGINEER.••�Q�,��• CALL N.C. ONE CALL CENTER BEFORE YOU DIG STOP 1- 800 - 632 -4949 AVOID UTILITY DAMAGE / FINAL DRAWINGS FOR REVIEW PURPOSES ONLY z O z LU X LU LU ry 0 z O 0- LU 0 J Z) O m 0 6 cY) I-- N 0 J z O W O n ry Z) n LU LU > 0 O z Q 0 Q z_ LL THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY, IN WRITING, OF ANY DISCREPANCIES OR OMISSIONS TO THE TOPOGRAPHIC INFORMATION. THE CONTRACTOR(S) SHALL BE RESPONSIBLE FOR CONFIRMING THE LOCATION (HORIZONTAL AND VERTICAL) OF ANY BURIED CABLES, CONDUITS, PIPES, AND STRUCTURES (STORM SEWER, SANITARY SEWER, WATER, GAS, TELEVISION, TELEPHONE, ETC.) WHICH IMPACT THE CONSTRUCTION SITE. THE CONTRACTOR(S) SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES ARE FOUND BETWEEN THE ACTUAL CONDITIONS VERSUS THE DATA CONTAINED IN THE CONSTRUCTION PLANS. ANY COSTS INCURRED AS THE RESULT OF NOT CONFIRMING THE CONDUITS, PIPES, AND STRUCTURES SHALL BE BORNE BY THE CONTRACTOR. SURVEY REFERENCES: DEED BOOK 1492, PAGE 581 DEED BOOK 1198, PAGE 510 DEED BOOK 833, PAGE 752 DEED BOOK 1461, PAGE 244 PROTECT EX. SANITARY SEWER FORCE MAIN TO REMAIN (TYP.)—, I \ \ INLET PROTEC ON EX. CWD #30 � (TO REMAIN) I UPSTREAM INV 53 DOWNSTREAM INV 53 PROTECT EX. VAL W / Ri CONTRACTOR SHE EX. DIVERSION DITCHES & CHECK cV rcArmncecV f1nAicrcu /1nnA1 I / GENERAL NOTES: 1. REFER TO THE FOLLOWING MCKIM & CREED, INC. CONSTRUCTION PLANS, AND ALL SUBSEQUENT CONSTRUCTION BULLETINS FOR INFORMATION ON EXISTING SITE INFRASTRUCTURE: — BRIAR CHAPEL — GRANITE MILL BOULEVARD AND BOULDER POINT DRIVE CONSTRUCTION PLANS SEALED JUNE 8, 2010 — BRIAR CHAPEL — PHASE 5 NORTH CONSTRUCTION PLANS SEALED MARCH 30, 2011 — BRIAR CHAPEL — BRIAR CHAPEL PARKWAY AND BOULDER POINT DRIVE EXTENSION SEALED JANUARY 31, 2012 — BRIAR CHAPEL — PHASE 6 SOUTH CONSTRUCTION PLANS SEALED JANUARY 27, 2012 — BRIAR CHAPEL — GREAT RIDGE PARKWAY CONSTRUCTION PLANS SEALED APRIL 4, 2013. — BRIAR CHAPEL — PHASE 7 CONSTRUCTION PLANS SEALED MAY 29, 2013. — BRIAR CHAPEL — PHASE 8 CONSTRUCTION PLANS SEALED AUGUST 25, 2013. — BRIAR CHAPEL — PHASE 9 CONSTRUCTION PLANS SEALED MAY 9, 2014. — BRIAR CHAPEL — GRANITE MILL BOULEVARD REALIGNMENT PLANS SEALED JUNE 2, 2014. — BRIAR CHAPEL — PHASE 11 CONSTRUCTION PLANS SEALED SEPTEMBER 9, 2014. 2. REFER TO THE FOLLOWING JOHN R. MCADAMS COMPANY, INC. CONSTRUCTION PLANS, AND ALL SUBSEQUENT CONSTRUCTION BULLETINS FOR INFORMATION ON EXISTING SITE INFRASTRUCTURE: — BRIAR CHAPEL — RECLAMATION FACILITY EROSION CONTROL PLAN SEALED JULY 29, 2005 — BRIAR CHAPEL — PHASE 1 CONSTRUCTION PLANS SEALED OCTOBER 21, 2005. — BRIAR CHAPEL — WEST EXTENSION GRADING PLAN (INTERIM) SEALED MARCH 1, 2007. — BRIAR CHAPEL — PHASE 3 CONSTRUCTION PLANS SEALED DECEMBER 4, 2006. — BRIAR CHAPEL — PHASE 4 CONSTRUCTION PLANS SEALED JANUARY 15, 2007. — BRIAR CHAPEL — WATER QUALITY PONDS 5 AND 6 CONSTRUCTION PLANS SEALED AUGUST 24, 2006. — BRIAR CHAPEL — PUMP STATION CONSTRUCTION PLANS DATED APRIL 3, 2006. — BRIAR CHAPEL — PHASE 4 — POD D CONSTRUCTION PLANS SEALED SEPT. 17, 2007. — BRIAR CHAPEL — PHASE 3 & 4 EROSION CONTROL PLANS SEALED JULY 26, 2007. — BRIAR CHAPEL — PHASE 5 SOUTH SECTION 1 CONSTRUCTION PLANS SEALED NOVEMBER 9, 2009. — BRIAR CHAPEL — PHASE 5 SOUTH SECTION 2 CONSTRUCTION PLANS SEALED OCTOBER 8, 2009. — BRIAR CHAPEL — PHASE 6 NORTH SECTIONS 1 AND 2 CONSTRUCTION PLANS SEALED OCTOBER 8, 2012. 3. THIS PROPERTY IS ZONED CC —CUD. 4. ALL DISTANCES SHOWN ARE HORIZONTAL GROUND MEASUREMENTS. 5. BEARINGS SHOWN HEREON ARE BASED ON NC GRID NAD83. THIS PROJECT IS LOCALIZED ABOUT NCGS MONUMENT "MEACHAM" HAVING NC GRID COORDINATES N: 768,395.12', E: 1,963,424.93' USING A COMBINED FACTOR OF 0.99990676. 6. EXISTING TOPOGRAPHIC DATA IS BASED ON AERIAL MAPPING PERFORMED BY AVIOIMAGE MAPPING SERVICES IN FEBRUARY 2010. ELEVATIONS ARE BASED ON NAVD 88 NCGS MONUMENT "F -92" WITH AN ELEVATION OF 476.06'. 7. HORIZONTAL AND VERTICAL CONTROL FOR THIS SITE WAS INSTALLED BY GPA PROFESSIONAL LAND SURVEYORS OF NC. 8. PROJECT IS LOCATED IN THE CAPE FEAR RIVER BASIN. 9. STREAM AND WETLAND LOCATIONS ARE BASED ON DELINEATIONS PROVIDED BY SOIL AND ENVIRONMENTAL CONSULTANTS IN RALEIGH, NC — CONTACT NIKKI THOMSON AT 919 - 846 -5900. 10. NO PORTION OF THIS PROPERTY IS LOCATED IN SPECIAL FLOOD HAZARD AREA "AE" AS SHOWN ON FEMA FIRM MAP #3710976500J DATED FEBRUARY 2, 2007. SEAL 1 I ISSUED FOR PERMITTING 2015.04.17 I REV. NO. DESCRIPTIONS DATE REVISIONS SEAL \,,, ,,\ I I I I I I I I ///,/// AX" = 036348 C., 04/17/2015 v v qKM&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233 -8091, Fax: (919)233 -8031 F -1222 www.mckimcreed.com DEMOLITION NOTES: 1. NO EARTH— DISTURBING ACTIVITIES SHALL COMMENCE UNTIL ALL PERIMETER EROSION CONTROL MEASURES ARE IN PLACE IN ACCORDANCE WITH THE EROSION CONTROL SEQUENCE SHOWN IN THESE PLANS. 2. NO EARTH— DISTURBING ACTIVITY OR OTHER WORK SHALL TAKE PLACE WITHIN WETLAND AREAS NOTED ON SURVEY. CONTRACTOR SHALL FIELD VERIFY WETLAND LIMITS FLAGGING IS IN PLACE AND SHALL NOT ENTER WETLAND AREAS. IF WETLAND FLAGGING IS MISSING OR OTHERWISE DAMAGED, IT IS CONTRACTOR'S RESPONSIBILITY TO NOTE WETLAND LIMITS AND PREVENT DISTURBANCE OR OTHER ACTIVITY WITHIN WETLANDS. 3. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR THE PROTECTION OF ALL PROPERTY CORNER MONUMENTS, AND SHALL HAVE, AT HIS EXPENSE, ALL CORNER MONUMENTS REPLACED WHICH ARE DISTURBED BY CONSTRUCTION ACTIVITIES. 4. CONTRACTOR IS RESPONSIBLE FOR REPAIRS OF DAMAGE TO ANY EXISTING IMPROVEMENTS, AT HIS EXPENSE, DURING CONSTRUCTION, SUCH AS, BUT NOT LIMITED TO, DRAINAGE, UTILITIES, PAVEMENT, STRIPING, CURB, ETC. REPAIRS SHALL BE EQUAL TO OR BETTER THAN EXISTING CONDITIONS. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING THE PUBLIC DURING CONSTRUCTION, WHICH INCLUDES, BUT IS NOT LIMITED TO, CONSTRUCTION FENCING, BARRICADES, SIGNAGE, ETC. 6. CONTRACTOR SHALL COMPLY TO THE FULLEST EXTENT WITH ALL REGULATIONS GOVERNING THE DEMOLITION, REMOVAL, TRANSPORTATION AND DISPOSAL OF ALL DEMOLITION DEBRIS. 7. CONTRACTOR SHALL COMPLY TO THE FULLEST EXTENT WITH THE LATEST OSHA STANDARDS FOR EXCAVATION AND TRENCHING PROCEDURES. CONTRACTOR SHALL USE SUPPORT SYSTEMS, SLOPING, BENCHING, ETC. AS NECESSARY FOR THESE OPERATIONS, AND SHALL COMPLY WITH ALL OSHA PERFORMANCE CRITERIA. 8. CONTRACTOR SHALL TAKE SPECIAL CARE TO PROTECT ALL UTILITIES AND APPURTENANCES TO REMAIN. LEGEND- - — — — — — — — — — — 10' NO BUILD BUFFER LINE ----- - - - - -- RIPARIAN BUFFER LINE EX. CONTOUR EX. POWER LINE EASEMENT OVERHEAD POWER LINE EX. FORCE MAIN EASEMENT EX. SANITARY SEWER FORCE MAIN EX. REUSE IRRIGATION MAIN - EX. WATER MAIN EX. STORM DRAINAGE PIPE EX. LIMITS OF DISTURBANCE BRIAR-7SKCHAPEL'� by Newland COMMUNITIES BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA EXISTING CONDITIONS/ DEMOLITION PLAN CALL N.C. ONE CALL CENTER '006 Nb16, BEFORE YOU DIG STOP 1- 800 -632 -4949 AVOID UTIUTY 40 DAMAGE NORTH 50' 0 50' 100' SCALE: 1 " =50' (Horiz.) r DATE: -144 APRIL 17, 2015 MCE PROS. # 02735 -0113 D RAW N BSS DESIGNED BSS CHECKED GCA PRO3. MGR. CHS N/A STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY 1 MBC FILE NUMBER SCALE C0.2 HORIZONTAL: DRAWING NUMBER 1" = 50' VERTICAL: CO. 2 N/A STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY 1 LEGEND- - — — R/W LINE -- FUTURE R/W LINE EXISTING R/W LINE HOA EASEMENT LINE — — — — — — — — — — — PUBLIC UTILITY EASMENT LINE PUBLIC DRAINAGE EASEMENT EXISTING POWER LINE EASEMENT OE OVERHEAD POWER LINE ----- - - - - -- 10' NO BUILD BUFFER LINE ----- - - - - -- RIPARIAN BUFFER LINE • — BMP MAINENANCE & ACCESS EASEMENT ROADWAY CENTERLINE SITE GENERAL NOTES: 1. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY OWNER IF ANY DISCREPANCIES EXIST PRIOR TO CONSTRUCTION. NO ADDITIONAL COMPENSATION WILL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2. REFER TO THE FOLLOWING MCKIM & CREED, INC. CONSTRUCTION PLANS, AND ALL SUBSEQUENT CONSTRUCTION BULLETINS FOR INFORMATION ON EXISTING SITE INFRASTRUCTURE: - BRIAR CHAPEL - GRANITE MILL BOULEVARD AND BOULDER POINT DRIVE CONSTRUCTION PLANS SEALED JUNE 8, 2010 - BRIAR CHAPEL - PHASE 5 NORTH CONSTRUCTION PLANS SEALED MARCH 30, 2011 - BRIAR CHAPEL - BRIAR CHAPEL PARKWAY AND BOULDER POINT DRIVE EXTENSION SEALED JANUARY 31, 2012 - BRIAR CHAPEL - PHASE 6 SOUTH CONSTRUCTION PLANS SEALED JANUARY 27, 2012 - BRIAR CHAPEL - GREAT RIDGE PARKWAY CONSTRUCTION PLANS SEALED APRIL 4, 2013. - BRIAR CHAPEL - PHASE 7 CONSTRUCTION PLANS SEALED MAY 29, 2013. - BRIAR CHAPEL - PHASE 8 CONSTRUCTION PLANS SEALED AUGUST 25, 2013. - BRIAR CHAPEL - PHASE 9 CONSTRUCTION PLANS SEALED MAY 9, 2014. - BRIAR CHAPEL - GRANITE MILL BOULEVARD REALIGNMENT PLANS SEALED JUNE 2, 2014. 3. REFER TO THE FOLLOWING JOHN R. MCADAMS COMPANY, INC. CONSTRUCTION PLANS, AND ALL SUBSEQUENT CONSTRUCTION BULLETINS FOR INFORMATION ON EXISTING SITE INFRASTRUCTURE: - BRIAR CHAPEL - RECLAMATION FACILITY EROSION CONTROL PLAN SEALED JULY 29, 2005 - BRIAR CHAPEL - PHASE 1 CONSTRUCTION PLANS SEALED OCTOBER 21, 2005. - BRIAR CHAPEL - WEST EXTENSION GRADING PLAN (INTERIM) SEALED MARCH 1, 2007. - BRIAR CHAPEL - PHASE 3 CONSTRUCTION PLANS SEALED DECEMBER 4, 2006. - BRIAR CHAPEL - PHASE 4 CONSTRUCTION PLANS SEALED JANUARY 15, 2007. - BRIAR CHAPEL - WATER QUALITY PONDS 5 AND 6 CONSTRUCTION PLANS SEALED AUGUST 24, 2006. - BRIAR CHAPEL - PUMP STATION CONSTRUCTION PLANS DATED APRIL 3, 2006. - BRIAR CHAPEL - PHASE 4 - POD D CONSTRUCTION PLANS SEALED SEPT. 17, 2007. - BRIAR CHAPEL - PHASE 3 & 4 EROSION CONTROL PLANS SEALED JULY 26, 2007. - BRIAR CHAPEL - PHASE 5 SOUTH SECTION 1 CONSTRUCTION PLANS SEALED NOVEMBER 9, 2009. - BRIAR CHAPEL - PHASE 5 SOUTH SECTION 2 CONSTRUCTION PLANS SEALED OCTOBER 8, 2009. - BRIAR CHAPEL - PHASE 6 NORTH SECTIONS 1 AND 2 CONSTRUCTION PLANS SEALED OCTOBER 8, 2012. 4. STREAM AND WETLAND LOCATIONS ARE BASED ON DELINEATIONS PROVIDED BY SOIL AND ENVIRONMENTAL CONSULTANTS IN RALEIGH, NC - CONTACT NIKKI THOMSON AT 919 - 846 -5900. 5. A PORTION OF THIS PROPERTY IS LOCATED IN SPECIAL FLOOD HAZARD AREA "AE" AS SHOWN ON FEMA FIRM MAP #3710976500J DATED FEBRUARY 2, 2007. 6. ALL PROPOSED ROADWAY DIMENSIONS AS SHOWN ARE MEASURED FROM BACK OF CURB TO BACK OF CURB, ALL PROPOSED ALLEY DIMENSIONS AS SHOWN ARE MEASURED FROM EDGE OF PAVEMENT TO EDGE OF PAVEMENT, UNLESS NOTED OTHERWISE. 7. BEFORE STARTING ANY CONSTRUCTION OF IMPROVEMENTS WITHIN ANY NCDOT STREET OR HIGHWAY RIGHT -OF -WAY, CONTACT NCDOT DISTRICT OFFICE AND OBTAIN ALL PERMITS AND ENCROACHMENTS. KEEP COPIES ON CONSTRUCTION SITE. ALSO CONTACT NCDOT DISTRICT OFFICE 24 HOURS IN ADVANCE BEFORE PLACING CURB AND GUTTER AT 336 - 629 -1423. 8. REFER TO PLAN AND PROFILE SHEETS FOR DETAILED SANITARY SEWER AND STORM DRAINAGE INFORMATION WITHIN PUBLIC ROADS AND PRIVATE ALLEYS. CHATHAM COUNTY REQUIRED SITE NOTES 1. PROPERTY OWNER /DEVELOPER: NNP BRIAR CHAPEL, LLC 16 WINDY KNOLL CIRCLE CHAPEL HILL, NC 27516 PHONE: (919) 951 -0700 2. SITE AKPAR #. 82024 ALIGNMENT LINE DATA LINE # LENGTH BEARING L7 100..35' N64'00'70 "W L2 753.62' S85 °44'04 "W L3 707.47' N72 °77'53 "W L4 796.11' N83 °41'43 "W ALIGNMENT CURVE DATA CURVE # ARCH LENGTH RADIUS CHORD BEARING CHORD LENGTH DELTA C1 150.50' 750.00' N77'56'48 "W 750.25' 77 29'50" C2 237.09' 600.00' N83 °73'54 "W 229.67' 22 °04'03" C3 316.97' 600.00' N79 °08'03 "W 313.24' 30 °15'46" EX. OVERHEAD ELECTRIC (Typ.) OE BMP MAINTENANCE & ACCESS EASEMENT ill of • OE • \ of PUBLIC DRAINAGE EASEMENT 15' EACH SIDE, 20' EACH END �1 OF PIPE OR LAST STRUCTURE — — rj c PUBLIC DRAINAGE EASEMENT—' / 15' EACH SIDE, 20' EACH END / Q% OF PIPE OR LAST STRUCTURE I I CHATHAM COUNTY NO -BUILD BUFFER (TYP.) CHATHAM COUNTY STREAM \ BUFFER (TYP.) SEAL 1 I ISSUED FOR PERMITTING 2015.04.17 I REV. NO. DESCRIPTIONS DATE REVISIONS zz- ` �\ SEAL \ ,, , , , \ I I I I I I I I ///,// ,, 036348 C.• 04/17/2015 --I r—­-Q"wU1rK_.J1I DRIVF1 O-r � : (2T S-13, 40' PUBLIC POW) — — — — — — — — GUARDRAIL PLACED 0.5 FROM BACK OF C0.5' 4' PRIVATE U77LITY EASEMENT (T1P.) 00 TAINING WALL 4' HOA EASEMENT Otl- ESIGNED BY OTHERS) (TYP) + v v qKM&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233 -8091, Fax: (919)233 -8031 F -1222 www.mckimcreed.com tl- ---V---- � - IFIVIIIII PUBLIC DRAINAGE EASEMENTS �. 15' EACH SIDE, 20' EACH END OF PIPE OR LAST STRUCTURE \ \�\� 71 CL Aj� CHATHAM COUNTY 10' I I I pp \ � NO -BUILD BUFFER (TYP.) '1 I I X 77E TO EX. BOULDER POINT- I � CHATHAM COUNTY STREAM DRIVE - BUFFER (TYP.)� I I Qp pC I I I p0 I p I I I I I I BRIAR�CHAPEL'� Newland COMMUNITIES BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA SITE PLAN ro ' CALL N.C. ONE CALL CENTER BEFORE YOU DIG STOP 1- 800 -632 -4949 AVOID UTIUTY DAMAGE / 4 '006N&., 0 NORTH 50' 0 50' 100' SCALE: 1 " =50' (Horiz.) r DATE: -144 APRIL 17, 2015 MCE PROS. # 02735 -0113 D RAW N BSS DESIGNED BSS CHECKED GCA PROS. MGR. CHS SCALE MBC FILE NUMBER HORIZONTAL: DRAWING NUMBER AS NOTED VERTICAL: C 1 . 1 N/A STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY 1 LEGEND: R/W LINE EXISTING R/W LINE HOA EASEMENT LINE — — — — — — — — — — — PUBLIC UTILITY EASEMENT LINE PUBLIC DRAINAGE EASEMENT EX. POWER LINE EASEMENT OE OVERHEAD POWER LINE — BMP MAINTENANCE & ACCESS EASEMENT 10' NO BUILD BUFFER LINE RIPARIAN BUFFER LINE EX. SANITARY SEWER FORCE MAIN EX. REUSE IRRIGATION MAIN ............... ............................... .... ..................... ............................... EX. WATER MAIN NEW STORM DRAINAGE PIPE FUTURE ROAD EX. ACCESS DRIVE TO WWTF PROTECT EX. WATER MAIN TO REMAIN (TYP.) % — — FUTURE DRIVE) — — — .. PROTECT EX. VALVES TO REMAIN \ 36" RCP TO REMAIN PUBLIC DRAINAGE EASEMENT 15' EACH SIDE, 20' EACH END OF PIPE OR LAST STRUCTURE \ \�... PUBLIC DRAINAGE EASEMENT) 15' EACH SIDE, 20' EACH END OF PIPE OR LAST STRUCTURE \ CHATHAM COUNTY NO —BUILD BUFFER (TYPA CHATHAM COUNTY STREAM II 1 BUFFER (TYP.)�� SEAL 1 I ISSUED FOR PERMITTING 2015.04.17 I REV. NO. DESCRIPTIONS DATE REVISIONS \ CONTRACTOR SHALL VERIFY EXACT LOCATIONS OF EX. TELEPHONE AND ELECTRIC U 17LI TIES AND ENSURE THEY ARE NOT DISTURBED DURING CONSTRUCTION UTILITY NOTES: 1. ALL SANITARY SEWER CONSTRUCTION IS TO BE PERFORMED IN ACCORDANCE WITH CURRENT NCDENR & CHATHAM COUNTY STANDARDS, SPECIFICATIONS & DETAILS. 2. ALL WATER MAIN CONSTRUCTION IS TO BE PERFORMED IN ACCORDANCE WITH CURRENT CHATHAM COUNTY STANDARDS, SPECIFICATIONS & DETAILS. 3. ALL PERMITS RELATING TO THIS PROJECT MUST BE OBTAINED PRIOR TO CONSTRUCTION. 4. ALL WATER MAINS SHALL HAVE A MIN. OF 3' -6" OF COVER AS MEASURED FROM FINISHED GRADE TO TOP OF PIPE AT THE LOCATION WHERE INSTALLED. 5. WATER MAINS SHALL BE LAID AT LEAST 10 FEET LATERALLY FROM EXISTING OR PROPOSED SEWERS, UNLESS LOCAL CONDITIONS OR BARRIERS PREVENT A 10 —FOOT LATERAL SEPARATION, IN WHICH CASE: (1) THE WATER MAIN IS LAID IN A SEPARATE TRENCH, WITH THE ELEVATION OF THE BOTTOM OF THE WATER MAIN AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER; OR (2) THE WATER MAIN IS LAID IN THE SAME TRENCH AS THE SEWER WITH THE WATER MAIN LOCATED AT ONE SIDE ON A BENCH OF UNDISTURBED EARTH, AND WITH THE ELEVATION OF THE BOTTOM OF THE WATER MAIN AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER. WHERE A WATER MAIN CROSSES OVER A SANITARY SEWER, THE WATER MAIN SHALL BE LAID AT SUCH AN ELEVATION THAT THE BOTTOM OF THE WATER MAIN IS AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER, UNLESS LOCAL CONDITIONS OR BARRIERS PREVENT AN 18 —INCH VERTICAL SEPARATION — IN WHICH CASE BOTH THE WATER MAIN AND SEWER SHALL BE CONSTRUCTED OF DUCTILE IRON AND WITH JOINTS THAT ARE EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10 FEET ON EACH SIDE OF THE POINT OF CROSSING. WHERE A WATER MAIN CROSSES UNDER A SANITARY SEWER, BOTH THE WATER MAIN AND SEWER SHALL BE CONSTRUCTED OF DUCTILE IRON AND WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10 FEET ON EACH SIDE OF THE POINT OF CROSSING. A SECTION OF WATER MAIN PIPE SHALL BE CENTERED AT THE POINT OF CROSSING. SEE NCAC 15A, 18C, SECTION .0906. 6. CONTRACTOR SHALL USE A MIN. 20' SECTION DIP CLASS 350 CENTERED UNDER STORMWATER PIPE WHERE 18" MIN. VERTICAL CLEARANCE CANNOT BE MET BETWEEN STORMWATER AND WATER. 7. TRACER WIRE AND TRACER WIRE TEST STATIONS ARE TO BE INSTALLED ON ALL WATER MAINS. TRACER WIRE TEST STATIONS ARE TO BE LOCATED AT ALL FIRE HYDRANTS WITHIN A 3 FOOT RADIUS OF THE HYDRANT AND PREFERABLY TO THE REAR OF THE HYDRANT. 8. WATER SERVICES SHALL BE EXTENDED FROM THE MAIN TO A METER BOX LOCATED WITHIN THE RIGHT OF WAY. THE METER SHALL BE PLACED AT THE EDGE OF THE SERVICED LOT'S RIGHT OF WAY LINE OR EASEMENT. SERVICE LINE SHALL BE RUN ON A TRUE LINE FROM THE WATER MAIN TO THE METER BOX, AND WHERE POSSIBLE, SERVICE LINE SHALL BE PERPENDICULAR TO THE MAIN LINE. NO WATER BOXES OR VAULTS SHALL BE PLACED IN STREETS, SIDEWALKS, PARKING AREAS, OR DRIVEWAYS. 9. MANHOLES SHALL BE SPACED A MAXIMUM DISTANCE OF 400 FEET APART. 10. MANHOLES SHALL BE INSTALLED AT EACH DEFLECTION OF LINE AND /OR GRADE WITH A MINIMUM DROP OF 0.2 FEET. MANHOLES FOR SEWERS GREATER THAN 21 INCHES IN DIAMETER SHALL BE 5 FOOT MANHOLES. MANHOLES FOR SEWERS 12 FEET OR DEEPER SHALL BE MINIMUM 5 FOOT DIAMETER. MANHOLE TOPS SHALL BE SET FLUSH WITH PAVEMENT WHERE INSTALLED IN A STREET. 11. SERVICE CONNECTIONS FOR THE SANITARY SEWER LINES SHOULD BE PERPENDICULAR FROM THE MAIN LINE TO THE EDGE OF THE SERVICED LOT'S RIGHT OF WAY LINE OR EASEMENT WITH A MINIMUM GRADE OF 1/4 INCH /FOOT FOR 4 INCH AND .6 FOOT /100 FOOT FOR 6 INCH. ALL CLEANOUTS SHALL EXTEND A MINIMUM OF 6 INCHES ABOVE THE FINISHED GRADE. WHERE A SERVICE LINE IS CONNECTED TO A MANHOLE, THE LINE SHALL TERMINATE AT THE EDGE OF THE INVERT IN THE MANHOLE. NO CLEANOUTS SHALL BE PLACED IN STREETS, SIDEWALKS, PARKING AREAS, OR DRIVEWAYS. 12. ALL SANITARY SEWER LINES ARE 8" PVC SDR 35 UNLESS OTHERWISE NOTED AND ALL WATER MAIN LINES ARE 6" DI CLASS 350 UNLESS OTHERWISE NOTED. ALL SANITARY SEWER SERVICES ARE 4" SCHEDULE 40 PVC AND ALL WATER MAIN SERVICES ARE 1". 13. MINIMUM COVER OF 5 FEET IN TRAFFIC AREAS TO BE PROVIDED FOR ALL COLLECTOR LINES 4 INCHES AND LARGER. IF LESS THAN 5 FEET, DUCTILE IRON PIPE SHALL BE REQUIRED. 14. USE WATERTIGHT RIMS FOR SANITARY SEWER MANHOLES LOCATED IN PAVED ALLEYS. 15. SANITARY SEWER WITHIN PRIVATE EASEMENTS TO BE OWNED, OPERATED AND MAINTAINED BY HOME OWNERS ASSOCIATION OR AGENT THEREOF. 16. WATER MAINS WILL BE 3.5' OFF CURB AND GUTTER UNLESS SHOWN OTHERWISE. 17. ALL WATER MAINS WITHIN PUBLIC EASEMENTS AND PUBLIC RIGHT —OF —WAY TO BE OWNED, OPERATED AND MAINTAINED BY CHATHAM COUNTY, AND WILL BE CONTAINED WITHIN 20' WIDE PUBLIC WATER LINE EASEMENT (MINIMUM) CENTERED ON THE PROPOSED WATER MAIN. 18. CONTRACTOR TO COORDINATE WITH CHATHAM COUNTY PUBLIC WORKS FOR ALL IRRIGATION SLEEVE SIZING. PUBLIC DRAINAGE EASEMENT EX. DUKE POWER EASEMENT 15' EACH SIDE, 20' EACH END OF PIPE OR LAST STRUCTURE EX. 12' WA TER MAIN / EX. ELECTRIC (TYP,) \ (TYP.) \ '1 — — SEAL \ ,, , , , , I I I I I I I I 1//j// ,, 036348 6)%. 04/17/2015 0/till 111 I I\ 111 SEX. SEWER FORCE MAIN 4' HOA EASEMENT-1 (TYP.) (TYP.) v v qKM&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233 -8091, Fax: (919)233 -8031 F -1222 www.mckimcreed.com =X. TELEPHONE PUBLIC DRAINAGE EASEMENT 15' EACH SIDE, 20' EACH END OF PIPE OR LAST STRUCTURE CONTRACTOR SHALL INSTALL CONCRE7 ENCASEMENT PER CHA774AM COUNTY STANDAA DETAILS IF VERTICAL SEPARATION IS LESS 7HAN U SEE DETAIL SHEET D2 PUBLIC DRAINAGE EASEMENT I 15' EACH SIDE, 20' EACH END I OF PIPE OR LAST S7RUCTURE I CHA 1HAM COUNTY 10' NO —BUILD BUFFER (TYP.) CHA7HAM COUNTY STREAM____ I BUFFER (TYP.) I 1 I 1 _ ' i BRIAR EL'M I by Newland COMMUNITIES I� I PROTECT EX. VALVES TO REMAIN I I I I I I I I \\ PROTECT EX. U77LITY S7RUCIURES TO REMAIN BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA UTILITY PLAN END OF EX. BOULDER POINT DRIVE CONSTRUCTION ' CALL N.C. ONE CALL CENTER BEFORE YOU DIG STOP 1- 800 -632 -4949 AVOID UTIUTY DAMAGE / 4 '006Nb6., 0 NORTH 50' 0 50' 100' SCALE: 1 " =50' (Horiz.) r DATE: -144 APRIL 17, 2015 MCE PROS. # 02735 -0113 D RAW N BSS DESIGNED BSS CHECKED GCA PROS. MGR. CHS N/A STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY 1 MBC FILE NUMBER SCALE C2.X HORIZONTAL: DRAWING NUMBER 1" = 50' VERTICAL: C2.1 N/A STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY 1 LEGEND: EXISTING POWER LINE EASEMENT OE OVERHEAD POWER LINE 10' NO BUILD BUFFER LINE RIPARIAN BUFFER LINE sF \TPF COMBINATION SILT /TREE PROTECTION FENCING TPF TREE PROTECTION FENCING EXISTING CONTOUR PROPOSED CONTOUR ..... EX. LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE 0 ADDITIONAL DISTURBED AREA STAGE 1 DIVERSION DITCH 000000000 TEMPORARY CONSTRUCTION ENTRANCE STAGE 1 CHECK DAM STAGE 1 ARC FILTER INLET PROTECTION STAGE 1 RIPRAP OUTLET PROTECTION PLAN FOR REFERENCE ONLY ' CALL N.C. ONE ` CALL CENTER BEFORE YOU DIG STOP 1- 800 -632 -4949 AVOID UMUTY \ DAMAGE / 4 '006 Nb16' 0 NORTH PER BC WEST STORAGE POND .. �.., \ \ / NOTE. EX. EROSION CONTROL CLEARING AND GRUBBING PLAN MEASURES APPROVED PER BC PHASE .: \ .. \ . \ ,.. ., ,. ,. .: \ •. MAIN�AIN EX. SlL T FENCE , .. \ T 19 �i cnoinic nnin coiiooinic of Hole � � \ ....„ , � � , ., � � , , � ., �..... _ �.. � .., � i I I :. RFPdIR dA/Y dR�dC Wl -l�R� ,,. SEAL 1 ISSUED FOR PERMITTING 2015.04.17 REV. NO. DESCRIPTIONS DATE REVISIONS SEAL \ ,, , , , \ I I I I I I I I 1//j// ,, % ��N...�?RO'' 036348 C., 04/17/2015 v v qKM&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233 -8091, Fax: (919)233 -8031 F -1222 www.mckimcreed.com BRIAR-7SKCHAPEL'� by Newland COMMUNITIES BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA STAGE 1 GRADING, DRAINAGE & EROSION CONTROL PLAN r DATE: -144 APRIL 17, 2015 MCE PROS. # 02735 -0113 D RAW N BSS DESIGNED BSS CHECKED GCA PROS. MGR. CHS SCALE MBC FILE NUMBER C3.X HORIZONTAL: DRAWING NUMBER 1" = 50' VERTICAL: C3.1 N/A STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY 1 GENERAL NOTES: 1. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY OWNER IF ANY DISCREPANCIES EXIST PRIOR TO CONSTRUCTION. NO ADDITIONAL COMPENSATION WILL BE PAID TO CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2. CONTRACTOR SHALL NOTIFY "NORTH CAROLINA ONE CALL AT 1- 800 - 632 -4949 AT LEAST 48 HOURS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR TO CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NORTH CAROLINA ONE CALL ". 3. OVERHEAD ELECTRIC LINES MAY EXIST ON THE SITE. CONTRACTOR SHALL CONTACT DUKE POWER AT (336) 634 -4633 PRIOR TO COMMENCING ANY ACTIVITY WITHIN 200 -FT OF DUKE POWER RIGHT OF WAY. 4. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL ARRANGE AND ATTEND A PRECONSTRUCTION CONFERENCE WITH CHATHAM COUNTY, OWNER AND ENGINEER. 5. EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND, ARE BASED ON BEST AVAILABLE RECORD DRAWINGS. 6. SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES GREATER THAN 3:1 (H: V) SHALL BE APPROVED, PLACED AND COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. THESE SOILS SHALL BE COMPACTED TO THE STANDARD PROCTOR MAXIMUM DRY DENSITY UNLESS OTHERWISE RECOMMENDED BY THE GEOTECHNICAL ENGINEER. 7. ALL GRADED AREAS SHALL BE SLOPED SUCH THAT NO AREAS OF STANDING WATER OCCUR AND ALL AREAS POSITIVELY DRAIN TO DRAINAGE STRUCTURES, SWALES OR STORMWATER MANAGEMENT FACILITIES. 8. CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL PROPERTY CORNERS AND SHALL REPLACE ALL MARKERS REMOVED IF DAMAGED DURING CONSTRUCTION. 9. CONTRACTOR IS RESPONSIBLE FOR ALL DEWATERING AS NECESSARY THROUGHOUT CONSTRUCTION. 10. CONTRACTOR IS RESPONSIBLE FOR ADHERING TO ALL PERMIT CONDITIONS, MONITORING AND REPORTING REQUIREMENTS. 11. REFER TO SHEET D2.1 FOR PROPOSED ROAD CROSS SECTION DETAILS AND PAVEMENT SCHEDULE. 12. GRADED SLOPES STEEPER THAN 3:1 SHALL BE STABILIZED WITH CURLER SINGLE NET ( CURLEX 1) MATTING BY AMERICAN EXCELSIOR COMPANY OR APPROVED EQUAL. 13. STREAM AND WETLAND LOCATIONS ARE BASED ON DELINEATIONS PROVIDED BY SOIL AND ENVIRONMENTAL CONSULTANTS IN RALEIGH, NC - CONTACT SEAN CLARK AT 919 - 846 -5900. 14. NO PORTION OF THIS PROPERTY IS LOCATED IN SPECIAL FLOOD HAZARD AREA "AE" AS SHOWN ON FEMA FIRM MAP #3710976500J DATED FEBRUARY 2, 2007. 15. EXISTING INFRASTRUCTURE AS SHOWN MAY BE UNDER CONSTRUCTION AND SHALL BE FIELD VERIFIED BY CONTRACTOR. -BRIAR CHAPEL PARKWAY AND BOULDER POINT DRIVE EXTENSION SEALED JANUARY 1, 2012 16. BEFORE STARTING ANY CONSTRUCTION OF IMPROVEMENTS WITHIN ANY NCDOT STREET OR HIGHWAY RIGHT -OF -WAY, CONTACT NCDOT DISTRICT OFFICE AND OBTAIN ALL PERMITS AND ENCROACHMENTS AND KEEP COPIES ON CONSTRUCTION SITE AT ALL TIMES. ALSO CONTACT NCDOT DISTRICT OFFICE 24 HOURS IN ADVANCE BEFORE PLACING CURB AND GUTTER AT (336) 629 -1423. STAGE 2 CONSTRUCTION SEQUENCE: 1. THE INTENT OF THE CONSTRUCTION SEQUENCE IS TO PROVIDE THE CONTRACTOR WITH A GENERAL GUIDE FOR CONSTRUCTION PURPOSES. THIS SEQUENCE IS NOT INTENDED TO OUTLINE ALL CONSTRUCTION ACTIVITIES ON THIS PROJECT. 2. ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CHATHAM COUNTY SOIL EROSION AND SEDIMENTATION CONTROL ORDINANCE. 3. ALL EROSION CONTROL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER RAINFALL EVENTS. NEEDED REPAIRS SHALL BE MADE IMMEDIATELY. 4. IF IT IS DETERMINED DURING CONSTRUCTION THAT SIGNIFICANT SEDIMENT IS LEAVING THE SITE, DESPITE PROPER IMPLEMENTATION AND MAINTENANCE, THE CONTRACTOR IS OBLIGATED TO TAKE ADDITIONAL CORRECTIVE ACTION. CONTACT CHATHAM COUNTY ENVIRONMENTAL QUALITY DEPARTMENT, OWNER'S REPRESENTATIVE AND ENGINEER WITH ANY ADDITIONAL MEASURES NEEDED. 5. CONTRACTOR SHALL ESTABLISH GROUNDCOVER ON DISTURBED AREAS WITHIN THE NUMBER OF CALENDAR DAYS AFTER COMPLETION OF GRADING PER THE SCHEDULE BELOW: GRADUAL SLOPES: (14) CALENDAR DAYS MODERATE SLOPES: (10) CALENDAR DAYS STEEP SLOPES: (7) CALENDAR DAYS SLOPES ARE AS DEFINED IN THE CHATHAM COUNTY SOIL EROSION AND SEDIMENTATION CONTROL ORDINANCE. 6. CONTRACTOR TO POST EROSION CONTROL PERMIT PROMINENTLY ON SITE AT ALL TIMES. 7. TEMPORARY CONSTRUCTION ENTRANCES, TEMPORARY DIVERSION DITCHES, SILT FENCING, TREE PROTECTION FENCING AND TEMPORARY SKIMMER BASINS WERE INSTALLED AS PART OF THE BC WESTERN STORAGE POND AND BC PHASE 15 CLEARING AND GRUBBING PLANS. CONTRACTOR SHALL INSPECT THESE DEVICES TO ENSURE COMPLIANCE PRIOR TO FINAL GRADING OPERATIONS. 8. BEGIN FINAL GRADING OPERATIONS FOR ROADWAY. 9. AS ELEVATIONS ARE BROUGHT TO FINAL GRADES AND STORM PIPING IS INSTALLED IN ROADWAY SECTIONS, CONTRACTOR SHALL INSTALL HARDWARE CLOTH AND GRAVEL INLET PROTECTION AS SHOWN ON PLANS. 10. CONTRACTOR SHALL ENSURE THAT ALL SEDIMENT LADEN RUNOFF IS DIRECTED TO ROADWAY INLET PROTECTION PRIOR TO REMOVAL OF ANY SKIMMER SEDIMENT BASINS. NO BASINS SHALL BE REMOVED UNTIL INSPECTED AND APPROVED BY CHATHAM COUNTY SESC STAFF. 11. PERFORM SEEDING AND MULCHING AS REQUIRED IN ACCORDANCE WITH THE TEMPORARY AND PERMANENT SEEDING SCHEDULES LOCATED ON SHEET D1.2 AND NOTE #5 OF THIS SEQUENCE 12. ONCE GROUNDCOVER HAS BEEN ESTABLISHED AND OTHER CONSTRUCTION IS COMPLETE, CONTACT CHATHAM COUNTY SOIL EROSION AND SEDIMENTATION AND ENGINEER FOR SITE INSPECTION BEFORE REMOVING ANY TEMPORARY EROSION CONTROL MEASURES OR CONVERTING BASINS TO PERMANENT BMPs. LIMITS OF DISTURBANCE NOTES: 1. SILT FENCE AND TREE PROTECTION FENCE LINES ALSO DELINEATE THE LIMITS OF DISTURBANCE. ALL SILT FENCING OR TREE PROTECTION FENCING SHALL BE INSTALLED INSIDE LIMITS OF DISTURBANCE. 2. LIMITS OF DISTURBANCE BEYOND PREVIOUSLY APPROVED AREAS: 1.35 ACRES STORM DRAINAGE NOTES: 1. STORM DRAINAGE PIPES SHALL BE: • RCP /CLASS III FOR STORM DRAINAGE INSIDE PUBLIC RIGHT -OF -WAY OR CONNECTING INTO STRUCTURE INSIDE PUBLIC RIGHT -OF -WAY IN ACCORDANCE WITH NCDOT STANDARDS UNLESS NOTED OTHERWISE. 2. ALL CONCRETE SHALL MEET A MINIMUM 3,000 PSI COMPRESSIVE STRENGTH. 3. ALL PIPE IN STORM DRAIN STRUCTURES SHALL BE STRUCK EVEN WITH INSIDE WALL. 4. THE INTERIOR SURFACES OF ALL STORM DRAINAGE STRUCTURES SHALL BE POINTED UP AND SMOOTHED TO AN ACCEPTABLE STANDARD USING MORTAR MIXED TO MANUFACTURER'S SPECIFICATIONS. 5. ALL BACKFILL SHALL BE NON- PLASTIC IN NATURE, FREE FROM ROOTS, VEGETATION MATTER, WASTE CONSTRUCTION MATERIAL OR OTHER OBJECTIONABLE MATERIAL. UTILIZED MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 6. MATERIALS DEEMED AS UNSUITABLE FOR BACKFILL PURPOSES BY THE OWNER'S REPRESENTATIVE SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. 7. BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER PIPE IS LAID. THE FILL AROUND THE PIPE SHALL BE THOROUGHLY COMPACTED TO 95% OF THE MAXIMUM DRY DENSITY OBTAINABLE WITH THE STANDARD PROCTOR TEST. THE TOP EIGHT (8) INCHES SHALL BE COMPACTED TO 100% STANDARD PROCTOR. 8. UNDER NO CIRCUMSTANCES SHALL WATER BE ALLOWED TO RISE IN UNBACKFILLED TRENCHES AFTER PIPE HAS BEEN PLACED. 9. ALL FLARED END SECTIONS DISCHARGING INTO WATER QUALITY PONDS WILL HAVE A CONCRETE PAD POURED UNDERNEATH THE FLARED END SECTION IN ACCORDANCE WITH PROVIDED CONSTRUCTION DETAILS. 10. RIM ELEVATIONS OF STORM DRAIN STRUCTURES SHALL BE FIELD VERIFIED. 11. STORM DRAINAGE WITHIN PRIVATE EASEMENTS TO BE OWNED, OPERATED AND MAINTAINED BY HOME OWNER'S ASSOCIATION OR AGENT THEREOF. 12. LENGTHS SHOWN FOR STORM DRAINAGE PIPES ARE MEASURED FROM CENTER OF STORM STRUCTURES AND TO ENDS OF FLARED END SECTIONS. SLOPES CALCULATED ARE BASED ON THIS LENGTH. 13. CB DENOTES CATCH BASINS TO BE INSTALLED IN THE CENTERS OF PAVED ALLEYS AND NON -PAVED AREAS. REFER TO NCDOT DETAILS 840.19 AND 840.24 ON SHEET D -2.2. 14. CI DENOTES CURB INLETS TO BE INSTALLED IN THE CURB LINES OF ROADWAYS. REFER TO NCDOT DETAILS 840.02 AND 840.03 ON SHEET D -2.2. ............. FUTURE SEAL 1 I ISSUED FOR PERMITTING 2015.04.17 I REV. NO. DESCRIPTIONS DATE REVISIONS SEAL 036348 C., 04/17/2015 v N4 qKM&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233 -8091, Fax: (919)233 -8031 F -1222 www.mckimcreed.com RETAINING WALL NOTES: 1. RETAINING WALL DESIGN IS BY OTHERS. OWNER SHALL PROCURE A QUALIFIED RETAINING WALL DESIGNER FOR THE PROJECT. RETAINING WALL INFORMATION SHOWN ON THESE PLANS ARE FOR LOCATION AND GRADE INFORMATION ONLY. OWNER RESPONSIBLE FOR PROVIDING NECESSARY INFORMATION TO WALL DESIGNER AS REQUIRED FOR PROPER DESIGN OF RETAINING WALLS. 2. TOP GRADE OF WALL AND BOTTOM GRADE OF WALL SPECIFIED IN PLANS ARE INTENDED TO BE THE FINISHED PAVEMENT OR EARTH GRADE. THE WALL DESIGNER SHALL ADJUST SHOP DRAWING WALL ELEVATIONS FOR THE TOP AND BOTTOM OF WALL TO MEET SPECIFIC PRODUCT DESIGN CRITERIA AND WALL GEOMETRY AS NECESSARY TO ACHIEVE DESIRED FINISHED GRADES. THE HORIZONTAL WALL LOCATION AS SHOWN IS THE FINISHED LOCATION OF THE BOTTOM OF WALL. THE WALL DESIGNER SHALL COORDINATE WITH THE ENGINEER TO VERIFY WHETHER CONFLICTS EXIST. THE WALL DESIGNER SHALL NOTIFY THE ENGINEER IN CASE OF ANY CONFLICTS, INCLUDING BUT NOT LIMITED TO EXISTING OR PROPOSED UTILITIES, WALL BATTER, GEOGRID PLACEMENT, ETC., OR IF ANY ASPECT OF WALL PLACEMENT CAN NOT BE ACCOMPLISHED. ALL WORK RELATED TO THE RETAINING WALL CONSTRUCTION SHALL BE ACCOMPLISHED WITHIN THE BOUNDARIES OF THE PROJECT PROPERTY, WITHOUT IMPACTING BUFFERS. 3. IT IS THE RESPONSIBILITY OF THE OWNER AND WALL DESIGNER TO ASSURE THAT THE REQUIRED SOIL BEARING PRESSURE, SUBSURFACE DRAINAGE AND SURFACE DRAINAGE ARE ACHIEVED AS RELATED TO THE RETAINING WALL DESIGN. THIS SHOULD BE VERIFIED BY A GEOTECHNICAL ENGINEER. SPECIAL ATTENTION IS REQUIRED TO ENSURE BEARING CAPACITY HAS BEEN ACHIEVED AT LOCATIONS WHERE PIPE PENETRATIONS ARE TO OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CLIENT TO PROVIDE QUALITY CONTROL / QUALITY ASSURANCE TESTING ASSOCIATED WITH THE WALL CONSTRUCTION. THE GEOTECHNICAL ENGINEER OR WALL DESIGNER SHALL PROVIDE ANY CERTIFICATIONS AS MAY BE REQUIRED TO SHOW COMPLIANCE WITH ORIGINAL DESIGN DOCUMENTS AS RELATED TO THE WALL DESIGN AND CONSTRUCTION. !� � ��jl I•�1 ��YL�lI �l L��YL� SELF - INSPECTION PROGRAM: THE SEDIMENTATION POLLUTION CONTROL ACT WAS AMENDED IN 2006 TO REQUIRE THAT PERSONS RESPONSIBLE FOR LAND - DISTURBING ACTIVITIES INSPECT A PROJECT AFTER EACH PHASE OF THE PROJECT TO MAKE SURE THAT THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN IS BEING FOLLOWED. RULES DETAILING THE DOCUMENTATION OF THESE INSPECTIONS TOOK EFFECT OCTOBER 1, 2010. THE SELF - INSPECTION PROGRAM IS SEPARATE FROM THE WEEKLY SELF - MONITORING PROGRAM OF THE NPDES STORMWATER PERMIT FOR CONSTRUCTION ACTIVITIES. THE FOCUS OF THE SELF - INSPECTION REPORT IS THE INSTALLATION AND MAINTENANCE OF EROSION AND SEDIMENTATION CONTROL MEASURES ACCORDING TO THE APPROVED PLAN. THE INSPECTIONS MUST BE CONDUCTED AFTER EACH PHASE OF THE PROJECT, AND CONTINUED UNTIL PERMANENT GROUND COVER IS ESTABLISHED IN ACCORDANCE WITH NCGS 113A -54.1 AND 15A NCAC 4B.0131. THE SELF - INSPECTION REPORT FORM IS AVAILABLE AS AN EXCEL SPREADSHEET FROM IF YOU HAVE QUESTIONS OR CANNOT ACCESS THE FORM, PLEASE CONTACT THIS OFFICE AT (919) 791 -4200. NPDES GROUNDCOVER STABILIZATION TIMEFIRAMES SITE AREA STABILIZATION TIMEFRAME DESCRIPTION PIPE DIAMETER EXCEPTIONS PERIMETER DIKES, 7 DAYS NONE SWALES, DITCHES, 522.20 522.00 SLOPES RCP 24.2 HIGH QUALITY WATER 7 DAYS NONE (HQW) ZONES 52230 18" SLOPES STEEPER 7 DAYS 14 DAYS FOR SLOPES THAN 3:1 DBL Cl -BPD -4 10' OR LESS IN 529.65 15" LENGTH AND NOT 24.5 0.82% STEEPER THAN 2:1 SLOPES 3:1 OR 14 DAYS 7 DAYS FOR SLOPES FLATTER RCP GREATER THAN 50' IN 5.06% PRINCIPLE SPILLWAY LENGTH ALL OTHER AREAS 14 DAYS NONE, EXCEPT FOR WITH SLOPES FLATTER 110.5 PERIMETERS AND HQW THAN 4:1 ZONES STORM DRAINAGE SUMMARY TABLE UPSTREAM STRUCTURE DOWNSTREAM STRUCTURE UPSTREAM INVERT DOWNSTREAM INVERT PIPE DIAMETER PIPE MATERIAL LENGTH (ft) SLOPE DBL Cl -BPD -1 HW -BPD -6 522.20 522.00 18" RCP 24.2 0.83% DBL CI -BPD -2 DBL CI -BPD -1 522.50 52230 18" RCP 24.5 0.829 DBL CI -BPD -3 DBL Cl -BPD -4 529.85 529.65 15" RCP 24.5 0.82% DBL CI -BPD -4 FES -BPD -5 526.00 524.00 15" RCP 39.5 5.06% PRINCIPLE SPILLWAY HW- BPD -11 51723 515.90 18" RCP 110.5 1.21% BRIAR-7SKCHAPEL'� by Newland COMMUNITIES 15011. TEMPORARY CONSTRUCTION ENTRANCE RIPRAP OUTLET PROTECTION ADDITIONAL DISTURBED AREA COMBINATION SILT /TREE PROTECTION FENCE TEMPORARY DIVERSION DITCH EXISTING CONTOUR PROPOSED CONTOUR ............... EX. LIMITS OF DISTURBANCE m m m m m m m LIMITS OF DISTURBANCE •0 ** SEDIMENT BASIN BAFFLE HARDWARE CLOTH & GRAVEL INLET PROT. ARC PIPE INLET PROTECTION CHECK DAM '�6N DUTnIUTY E 40 R IG NORTH 949 50' 0 50' 100' Y SCALE: 1"=50' (Horiz.) BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA STAGE 2 GRADING, DRAINAGE & EROSION CONTROL PLAN r DATE: -144 APRIL 17, 2015 MCE PROS. # 02735 -0113 D RAW N BSS DESIGNED BSS CHECKED GCA PROS. MGR. CHS SCALE MBC FILE NUMBER C3.X HORIZONTAL: DRAWING NUMBER 1" = 50' VERTICAL: C3.2 N/A STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY 1 PROTECT EX. VALVES TO REMAIN PROTECT EX. U77LITY STRUCTURES TO REMAINI CQ HW—BPD-11 0 I- CL CHATHAM COUNTY STREAM BUFFER (TYP.) CHATHAM COUNTY 10' NO —BUILD BUFFER (TYP.) PUBLIC DRAINAGE EASEMENT DBL Cl—BPD-1 15' EACH SIDE, 20' EACH END OF PIPE OR LAST STRUCTURE LO DBL CI—BPD-2 cl� A A- -er X0 ": EX. FES—BPD-10 PUBLIC DRAINAGE EASEMENT 15' EACH SIDE, 20' EACH END OF PIPE OR LAST STRUCTURE C3 101 LO 100 + PROTECT EX. VALVES TO C-4 + REMAIN ?07E-CT EX. VAL V�S To REMAIN 0 0 C14 LLJ c 77 -- — — — — — — — - - - -- . .. . ......... !!!7- . .... . �-7 . . ............... . . ............. S�: — ------ EX ELECTRIC (Typ.) EX. A (p EX. 12' WATER MAIN FES—BPD-5 (Typ-) DBL CI—BPD-4 PROTECT EX. WATER MAIN TO DBL Cl —BPD -3 REMAIN (TYP.) ,�--PUBLIC DRAINAGE EASEMENT A—EX. DUKE POWER EASEMENT 15' EACH SIDE, 20' EACH END OF PIPE OR LAST STRUCTURE PUBLIC DRAINAGE EASEMENT PROTECT EX. SANITARY SEWER 15' EACH SIDE, 20' EACH END FORCE MAIN TO REMAIN (TYP.) OF PIPE OR LAST STRUCTURE BOULDER POINT DRIVE EXTENSION PLAN (409 PUBLIC R/W, STA. 10+00 TO 22+50) 4,V*,wmt SCALE: 1"=50 NORTH 560 194 00 MCE PRO3. # 02735-0113 DRAWN C' DESIGNED BSS CHECKED GCA PROS. MGR. PROTECT EX. VALVES TO 77 REMAIN HW—BPD-11 0 I- CL CHATHAM COUNTY STREAM BUFFER (TYP.) CHATHAM COUNTY 10' NO —BUILD BUFFER (TYP.) PUBLIC DRAINAGE EASEMENT DBL Cl—BPD-1 15' EACH SIDE, 20' EACH END OF PIPE OR LAST STRUCTURE LO DBL CI—BPD-2 cl� A A- -er X0 ": EX. FES—BPD-10 PUBLIC DRAINAGE EASEMENT 15' EACH SIDE, 20' EACH END OF PIPE OR LAST STRUCTURE C3 101 LO 100 + PROTECT EX. VALVES TO C-4 + REMAIN ?07E-CT EX. VAL V�S To REMAIN 0 0 C14 LLJ c 77 -- — — — — — — — - - - -- . .. . ......... !!!7- . .... . �-7 . . ............... . . ............. S�: — ------ EX ELECTRIC (Typ.) EX. A (p EX. 12' WATER MAIN FES—BPD-5 (Typ-) DBL CI—BPD-4 PROTECT EX. WATER MAIN TO DBL Cl —BPD -3 REMAIN (TYP.) ,�--PUBLIC DRAINAGE EASEMENT A—EX. DUKE POWER EASEMENT 15' EACH SIDE, 20' EACH END OF PIPE OR LAST STRUCTURE PUBLIC DRAINAGE EASEMENT PROTECT EX. SANITARY SEWER 15' EACH SIDE, 20' EACH END FORCE MAIN TO REMAIN (TYP.) OF PIPE OR LAST STRUCTURE BOULDER POINT DRIVE EXTENSION PLAN (409 PUBLIC R/W, STA. 10+00 TO 22+50) 4,V*,wmt SCALE: 1"=50 NORTH 560 I APRIL 17, 2015 MCE PRO3. # 02735-0113 DRAWN BSS DESIGNED BSS CHECKED GCA PROS. MGR. CHS C4.1 N/A 560 555 PW STA 16+51.81 FW STA=19+81.17 555 L PW EL 543.72 f- V, A= =510� 507. A=:5.99Z L= 4.96: L=t49.67' ..................................... .................................... ..................................... .................................... ..................................... .................................... ..................................... .................................... ..................................... .................................... .................................... .................................... .................................... .................................... .................................... .................................... .................................... .......................................................................... .................................... .................................... .................................... .................................... .................................... .................................... .................................... .................................... ................................... K=, ................................... .................................... 00 .................................... .................................... .................................... .................................... .................................... .................................... .................................... .................................... .................................... .................................... ..................... K*25�00 .. ......... ........................... .................................... .................................... .................................... .................................... .................................... .................................... .................................... .................................... ......................... .. ..... ................................................................... to (0 550 CNL— + 550 to S1. cd k Q- 545 PV7 STA 11+2561 P101 13-1- 50 7 3 W (6 Ed 545 P w STA 10 +50.85 Pvl EL-525-99 -c; PW EL---52Z67 PW EL 527.84 A=J.2J7. A=4,587. 4. Q- Q- ri_ Cc: (L k ..................................... .................................... .................................... A = 1. .................................... 2J7. ...................... ..................................... .............. ............. L .................................... .................................... .................................... ......................... ........... .................................... .................................... 6.,62 ............ .................................... .................................... .................................... .................................... .................................... .................................. .................................... .................................... .................................... ......................................................................... .................................... ...... ............. . ........... .................................... ................................. ............. ................ ..... ............................. ......................... .......... .................................... .................................... .................................... ....... .......................... ............................... -Q) .............. ......................... . .... ... ... . ..................................... ....... ........................... .................................... .................................... .................................... .......................................................................... ............................. ........................................... .................................... .................................... L=419. 00' K=25. 31 K="-4.22 Rr 540 O Q) K=j 2.56 C-% I) —A 540 + CN: c� U-) F� �T U� Lt� % II to 4- 'z! Ci + C'q 11) + + + PROPOSED q 2.52 Z� O 00 Q) to �0 C"� tno 0 GRADE Q II C'4 535 (n 40f. 010, 535 k CL N�nccll N)k -Q, cr, k:: ik EX: GRADE Ad, I TCH ELEVA 77 ON A ..T ................. .................................. k (L ............... ..................... .. ....... ........... Ety .. .......... .................................... .................................... .................................... ............................... .................................... .................................... .................................... .................................... .................................... .................................... ............... ........... '0 .. . ....................... ... .................................... .................................... .................................... .................................... .................................... .................................... ............. ..................................... .................................... .................................... .................................... ......................... ........... .................................... .................................... .................................... .................................... .................................... .................................... .................. .................. .................................... ........ ......... ............... .................................... .................................... .................................... .................................... .................................... .................................... .................................... .................................... .................................... .................................... .................................... .................................... BC ULDER POINT D VE �T 530 C/� ck� 530 25Z 0.75. 465r 525 525 520 ........... ............................................................... ............................... ..... .......................... ............................... ................ ............... ............................... ..................................................... ............................. ...... ........................ ............................... ................. ............. ............................... .............................................................. ............................... ....... ...................... ............................... .................. ............ ............................... ............................ ............................... ...... ............................ ........ .............................. ......................... ................... .............................. ...... .................................... ..... ......................... ...... ........................... ......... .............................. ...... ................ .................... .............................. ...... .................................... .............................. ...... .......................... .......... .............................. ...... ............... ..................... .............................. ............................................ .............................. ...... ......................... ........... .............................. ...... .............. ...................... .............................. ...................................... ...... .............................. ...... ........................ ............ .............................. ...... ............. ....................... .............................. ...... .............................. ...... .............................. ............................... ............. .............................. ...... ............ ........................ ............................... ...... 520 515 515 cc Lf� CO 0) N,* �-o N-) r*, Ln:: C4 0� cq N:: co V) n -t:: V) :: Lo cq N�o --t n w m to co: 0) --t re) n: 0) Do co DO:: Of V) n: CO LQ OD [-:0 0 n:0 �-o 0) n: 00 01 ED co: co -t C4 n: it) r-- -t to pr) LO I0 LO: 0-) 0-): Ln pr) 0-): Pr) co --t:: 0-) LO: Lf) N go go r-- 0:: C4 (0 CC:: Pq C4 CD CD LO CD r*-- CD CD 0 C-0 00 Ln to 4 Lo CXD CO N 0) C-0 C4 CO C-0 0) 0 0: C4 0 N: co r-- 0) 0-) CXD N:OD o m: N o N: to dD L( to 0: 0 0-) C4 1--: 0) Ln to V) 0 0 Ln: F. 4 OD 03 03 rz . r-.. (_0 . . CO Ln CO Ln N - . CO LF) co LF) - . Co LO: to LF) to L(-): �D r*-. - . �D r*-. 1-- 00 DO: C)) 0-)0 0 N re) C4 1-):4 LF) Ui (6 CXD 00 0-) re) 0-)g CD:g CDC; �: - 0: 0 Do 0) 1-- 00 -0 : :6 LF), Ui L(-):: Ln pr) -'t -J- LQ - . L( -) : LQ �D 90 . P-- I-- OD 0) 06 N 0; co C; c\1 Ln 04 Lf) 04 N Ln Lc) Ln 04 N: C-4 N L0 Ln Lf) Ln C-4 N: C-4 Lf) Ln Lf) L(-) C-4 N: CS1 U) LF) I0 N LF) cq N: C-4 Lf) LO U) N LF) C-4 U) L(-) : 04 In N LF) 04 Lf) C-4 N LF) U) LO C-4 N: Lf) LF) C-4 N I0 LO re) n: n Lf) Ln 0 Ln W) it) n: Ln V) it) LO re) Lf) n: V) n Ln it) Ln n: 0 Ln re) U) LO U) Lo U) Ln 't -t it) Ln 11) Ln Lf) Ln Lf) L( Lf) L(-) Lf) n LF) pq Lf) n:, pq n LO Lf) LF) Lf) N; IM LF) Lf) n LF) V) I0 n: LF) :10 n LF) pr) Lf) n: pr) n Ln Lf) Ln Lf) Ln Lf) Ln Lf) n: pr) Lo Lf) n Ln Lf) Ln U) Lo U) Ln Lf) Ln Lf) Ln Ln Ln Ln 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 22+50 23+00 BOULDER POINT DRIVE EXTENSION PROFILE (STA. 10+00 TO 22+50) SCALE: (Horiz.) 1"=50'; (Vert.) 1 " =5' I I ISSUED FOR PERMITTING 2015.04.17 REV. NO. DESCRIPTIONS DATE REVISIONS SEAL L��\C4 ,?0 ,1111,,, 036348 04/17/2015 461N ........... -4, 4Qt # 'I qKM&CREED 4 *w*r*j N4 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com BRIAR -7SKC H A P E L "I L17 Newland COMMUNITIES BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA PLAN & PROFILE BOULDER POINT DRIVE STA. 10+00 TO STA. 22+50 r DATE: I APRIL 17, 2015 MCE PRO3. # 02735-0113 DRAWN BSS DESIGNED BSS CHECKED GCA PROS. MGR. CHS C4.1 N/A SCALE M8LC FILE NUMBER C4.X HORIZONTAL: DRAWING NUMBER 1" = 50- VERTICAL: C4.1 N/A 'STATUS: FINAL DRAWINGS REVISION ,,FOR REVIEW PURPOSES ONLY 1 -1-1 11 - FILTER CLOTH A. COARSE AGGREGATE (2 " -3" STONE) SHALL BE USED. PAD TO BE 100 -L X 25'W X 6 "D MIN. PLACE A MINIMUM OF 3" OF STONE IN A CUT SECTION TO HELP SECURE FILTER CLOTH. B. TURNING RADIUS SUFFICIENT TO ACCOMMODATE LARGE TRUCKS IS TO BE PROVIDED. C. ENTRANCES SHOULD BE LOCATED TO PROVIDE FOR MAXIMUM UTILITY BY ALL CONSTRUCTION VEHICLES. D. MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR DIRECT FLOW OF MUD ONTO STREETS. PERIODIC TOP DRESSING MAY BE NECESSARY. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS. E. TEMPORARY PADS MUST BE LOCATED ON EACH SIDE OF ADJOINING ROADWAY. TEMPORARY CONSTRUCTION ENTRANCE NTS 3 \\\ \ X, S 1 RIP RAP(SEE SECTION THRU BASIN BELOW) / 'how 111 \ INVERT \ PIPE \ W - 01 / / / / /llllllll llll� i . - / SEOIMEIyT STORAGE AREA -� /PERSPECTIVE VIEW NO SCALE AREAS TO BE DISTURBED (CUT, FILL, ETC.) _/ \ Azow SEDIMENT STORAGE -FLOOD STORAGE ZONE fly SILT FENCE TO BE INSTALLED OVER TOP OF PIPE (TYP'.) flTHPICK P HEADWALL S 3' HIGH MIN. RAP HEADWALL SILT FENCE NOTE: -_ dnmn --__PIPE DIMENSIONS ARE L PIPE INVERT FILTER FABRIC MINIMUM ACCEPTABLE UNLESS OTHERWISE CLASS 1 RIP -RAP NOTED. #57 WASHED STONE MAX. SEDIMENT DEPTH(CLEAN OUT POINT) SECTION THRU BASIN. FILTER AND CULVERT PIPE ARC FILTER INLET PROTECTION NTS ORANGE, UV RESISTANT HIGH TENSILE STRENGTH 6' 0. C. POLY BARRICADE FABRIC POSTS 4" PINE, 2" OAK 40" OR 1.33 LB /FT STEEL PROTECTION AREA DO NOT ENTER PARA PROTECCON: PROHIBIDO ENTRAR" Z EXISTING GRADE cV 1. WARNING SIGNS TO BE MADE OF DURABLE WATERPROOF PLASTIC. 2. ALL LETTERS TO BE AT LEAST 3" HIGH, CLEARLY LEGIBLE AND SPACED APPROPRIATELY. 3. SIGNS TO PLACES AT EACH END OF LINER PROTECTION AREA AND 200' ON CENTER (MAX.) THEREAFTER FOR PROTECTION AREA LESS THAN 200' IN PERIMETER PROVIDE NO LESS THAN ONE SIGN PER PROTECTION AREA AND /OR SIDE. 4. ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. FABRIC MUST BE ATTACHED TO APPROVED POSTS ONLY. DO NOT ATTACH TO TREES. 5. ADDITIONAL FENCING MAY BE REQUIRED BASED ON FIELD CONDITIONS. 6. FAILURE TO MAINTAIN PROTECTION FENCING MAY RESULT IN CIVIL PENALTIES. TREE PROTECTION FENCE NTS SEAL 1 ISSUED FOR PERMITTING 2015.04.17 REV. NO. DESCRIPTIONS DATE REVISIONS NOTE: STRUCTURAL STONE SHALL BE CLASS B STONE FOR EROSION CONTROL PURPOSES. SEDIMENT CONTROL STONE SHALL BE NO. 5 OF NO. 57 STONE. SILT FENCE 1.5' MIN. F�OW 3' MAX. SEDIMENTS STONE CONTROL STONE CROSS SECTION SEAL ... �M,, 0 ''', 036348 6)%. 04/17/2015 ENGINEER.• �Q�•\\. 2' FRONT VIEW SILT FENCE OUTLET NTS v qKM&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233 -8091, Fax: (919)233 -8031 F -1222 www.mckimcreed.com .h PROTECTION AREA DO NOT ENTER v 1 WARNING SIGN DETAIL TOP ELEVATION OF STORMWATER - - - - - - - - - - - - - - - - - =- #5 WASHED EXISTING SLOPE EXISTING SLOPES #1 RIP -RAP 0.5' -1' MAX. D 1 29 in VAKItS 1 CONSTRUCTION NOTES: HEIGHT & WIDTH DETERMINED BY EXISTING TOPOGRAPHY AND 0.5' -1' SEDIMENT STORAGE REQUIRED. w KEY RIP RAP INTO THE DAM m t KEYED RIP RAP FOR STABILIZATION. #5 WASHED STONE EXISnNG GROUND FRONT VIEW STEP SEQUENCE NOTE: REMOVE SEDIMENT ACCUMULATION FROM BEHIND CHECK DAMS TO PREVENT DAMAGE TO CHANNEL VEGETATION. FLOW SHOULD BE MAINTAINED THROUGH THE DAM. CHECK DAM NTS NOTES: 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. 2. DRIVE 5 -FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING THE INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET APART. 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE, AND BOTTOM. PLACING A 2 -FOOT FLAP OF THE WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS RECOMMENDED. 4. PLACE CLEAN GRAVEL (NC DOT #5 OR #57 STONE) ON A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES AROUND THE WIRE, AND SMOOTH TO AN EVEN GRADE. 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ACCUMULATED SEDIMENT, AND ESTABLISH FINAL GRADING ELEVATIONS. 6. COMPACT THE AREA PROPERLY AND STABILIZED IT WITH GROUNDCOVER. NCDOT #5 OR #57 WASHED STONE *FOR REPAIR OF SILT FENCE FAILURES, USE No. 57 WASHED STONE. FOR ANCHOR WHEN SILT FENCE IS PROTECTING CATCH BASIN. 8' MAX. VARIABLE AS DIRECTED BY THE ENGINEER NCDOT #5 0 WASHED PLAN VIEW HARDWARE CLOTH & GRAVEL INLET PROTECTION NTS ' • IIII ____ IIII III ��� IIII ■ ■ ■ ■r 1 ■ ■■ ■11111 II�I�.•. ❖,�.•.�I ■I PROTECTION AREA I ■r► ❖..1111 -INSTALLED TO SECOND 11p ;IR R"t Z11 WIRE FROM TOP 1........... •.•.. .............� ►..L , =� \II ------ ------------------------- - - - - -- - I -� I J_I BRIAR-7SKCHAPEL'� by Newland COMMUNITIES AUGE HARE CLOTH ESH_OPENINGS) 2' 16" MIN. COMBINATION SILTITREE PROTECTION FENCE NTS BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA EROSION AND SEDIMENTATION CONTROL DETAILS DATE: NOTES: MCE PROS. # 1. WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL. BSS 2. LETTERS TO BE 3" HIGH MINIMUM, CLEARLY LEGIBLE AND SPACED AS DETAILED. CHECKED 3. SIGNS SHALL BE PLACED AT 50' MAXIMUM INTERVALS. CHS 4. PLACE A SIGN AT EACH END OF LINEAR TREE PROTECTION AND 50' ON CENTER THEREAFTER. 5. FOR TREE PROTECTION AREAS LESS THAN 200' IN PERIMETER, PROVIDE NO LESS THAN MIN. 12 -1/2 GA. ONE SIGN PER PROTECTION AREA. INTERMEDIATE 6. ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. WIRES 7. MAINTAIN TREE PROTECTION FENCE THROUGHOUT DURATION OF PROJECT. 8. ADDITIONAL SIGNS MAY BE REQUIRED BY CHATHAM COUNTY BASED ON ACTUAL FIELD CONDITIONS. GRADE g. PLACE A SIGN AT EACH END OF LINEAR TREE PROTECTION AND 50' ON CENTER THEREAFTER. 10. FLOW SHALL NOT RUN PARALLEL WITH THE FENCE. 11. END OF SILT FENCE NEEDS TO BE TURNED UPHILL. 12. SEE NCDENR PRACTICE & SPECIFICATIONS MANUAL SEDIMENTS FENCE SECTION FOR CONDITIONS WHERE PRACTICE APPLIES AND DESIGN CRITERIA. COMBINATION SILTITREE PROTECTION FENCE NTS BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA EROSION AND SEDIMENTATION CONTROL DETAILS DATE: APRIL 17, 2015 MCE PROS. # 02735 -0113 D RAW N BSS DESIGNED BSS CHECKED GCA PROS. MGR. CHS SCALE M8LC FILE NUMBER D1.X HORIZONTAL: DRAWING NUMBER 1" = 50' VERTICAL: D1.1 N/A STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY 1 :1*01I171O`I.LI O -a SPECIES RATE (lb/acre) TALL FESCUE 80 KOBE LESPEDEZA 40 NURSE PLANTS: BETWEEN MAY 1 AND AUG. 15, ADD 10 lb/acre GERMAN MILLET OR 15 lb/acre SUDANGRASS. PRIOR TO MAY 1 OR AFTER AUG. 15, ADD 40 Ib /ac RYE (GRAIN) 6y212010[MRLtl *3 BEST POSSIBLE FALL AUG. 15 — SEPT. 15 AUG. 20 — OCT. 25 LATE WINTER: FEB. 15 — MAR. 21 FEB. 1 — APR. 15. FALL IS BEST FOR TALL FESCUE AND LATER WINTER FOR LESPEDEZAS. OVERSEEDING OF KOBE LESPEDEZA OVER FALL — SEEDED TALL FESCUE IS VERY EFFECTIVE. SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 lb/acre GROUND AGRICULTURAL LIMESTONE AND 750 lb/acre 10 -10 -10 FERTILIZER MULCH: APPLY 4.000 lb/acre STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: REFERTILIZE IN THE SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE. MAY BE MOWED ONCE OR TWICE A YEAR, BUT MOWING IS NOT NECESSARY. RESEED, FERTILIZE AND MULCH DAMAGED AREAS IMMEDIATELY. RECOMMENDATIONS FOR GRASS -LINED CHANNELS SEEDING MIXTURE SPECIES RATE lb /acre) TALL FESCUE 200 NURSE PLANTS: BETWEEN MAY 1 AND AUG. 15, ADD 10 lb/acre SUDANGRASS OR 15 lb/acre GERMAN MILLET. PRIOR TO MAY 1 OR AFTER AUG. 15, ADD 40 Ib /ac RYE (GRAIN) SEEDING DATES: BEST: AUG. 25 — OCT. POSSIBLE: FEB. — APR. 15 AVOID SEEDING FROM NOV. TO JAN. IF SEEDING MUST BE DONE AT THIS TIME, ADD 40 lb/acre RYE GRAIN AND USE A CHANNEL LINING THAT OFFERS MAXIMUM PROTECTION SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 4,000 lb/acre GROUND AGRICULTURAL LIMESTONE AND 1,000 lb/acre 10 -10 -10 FERTILIZER MULCH: USE ROLLED EROSION CONTROL PRODUCT TO COVER THE BOTTOM OF THE CHANNELS AND DITCHES, AND STAPLE SECURELY. THE LINING SHOULD EXTEND ABOVE THE HIGHEST CALCULATED DEPTH OF FLOW. ON CHANNEL SIDE SLOPES ABOVE THIS HEIGHT, AND IN DRAINAGES NOT REQUIRING TEMPORARY LININGS, APPLY 4,000 lb/acre GRAIN STRAW, AND ANCHOR STRAW BY STAPLING NETTING OVER THE TOP. MULCH AND ANCHORING MATERIALS MUST NOT BE ALLOWED TO WASH DOWN SLOPES WHERE THEY CAN CLOG DRAINAGE DEVICES. MAINTENANCE: INSPECT AND REPAIR MULCH FREQUENTLY. REFERTILIZE IN LATE WINTER OF THE FOLLOWING YEAR; USE SOIL TESTS OR APPLY 150 lb/acre 10- 10 -10. MOW REGULARLY TO A HEIGHT OF 2 -4 INCHES. NOTE: SEE NCDENR'S EROSION AND SEDIMENT CONTROL PLANNING DESIGN MANUAL SECTION 6.11 FOR ADDITIONAL PERMANENT SEEDING OPTIONS. PERMANENT SEEDING SCHEDULE NTS SEAL 1 I ISSUED FOR PERMITTING 2015.04.17 I REV. NO. DESCRIPTIONS DATE REVISIONS :1Xd•PI�I�`►UL� �► a :q RYE (GRAIN) 120 (15 ANNUAL LESPEDEZA (KOBE IN 50 THE PIEDMONT & COASTAL PLAIN, APPROXIMATELY 12" (30 CM) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT KOREAN IN MOUNTAINS COMPACTED SOIL AND FOLD REMAINING 12" (30 CM) PORTION OF RECPS BACK OVER SEED OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYOND JUNE SEEDING DATES: APART ACROSS THE WIDTH OF THE RECPS. CLASS B MOUNTAINS (ABOVE 2,500'): FEB. 15 — MAY 15 (BELOW 2,500'): FEB. 1 — MAY 1 PIEDMONT: JAN. 1 — MAY 1 COASTAL PLAIN: DEC. 1 — APR. 15 SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 lb/acre GROUND AGRICULTURAL LIMESTONE AND 750 lb/acre 10 -10 -10 FERTILIZER MULCH: APPLY 4.000 lb/acre STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. :440111f, I!IQ`I.7_� O „ -q SPECIES RATE (lb /acre) GERMAN MILLET 40 IN THE PIEDMONT AND MOUNTAINS, A SMALL — STEMMED SUDANGRASS MAY BE SUBSTITUTED AT A RATE OF 50 lb/acre. SEEDING DATES: MOUNTAINS MAY 15 — AUG. 15 PIEDMONT: MAY 1 — AUG. 15 COASTAL PLAIN: APR. 15 — AUG. 15 SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 lb/acre GROUND AGRICULTURAL LIMESTONE AND 750 lb/acre 10 -10 -10 FERTILIZER MULCH: APPLY 4.000 lb/acre STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. RECOMMENDATIONS FOR FALL SEEDING MIXTURE SPECIES RATE (lb /acre) RYE (GRAIN) 120 SEEDING DATES: MOUNTAINS: AUG. 15 — DEC. 15 COASTAL PLAIN AND PIEDMONT: AUG. 15 — DEC. 30 SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 lb/acre GROUND AGRICULTURAL LIMESTONE AND 750 lb/acre 10 -10 -10 FERTILIZER MULCH: APPLY 4.000 lb/acre STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOPDRESS WITH 50 lb/acre OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 lb/acre KOBE (PIEDMONT AND COASTAL PLAIN) OR KOREAN (MOUNTAINS) LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. TEMPORARY SEEDING SCHEDULE NTS 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. 2. RIP THE ENTIRE AREA TO 6 INCHES DEPTH. 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 4. APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL (SEE BELOW*). 5. CONTINUE TILLAGE UNTIL A WELL — PULVERIZED, FIRM, REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 INCHES DEEP. 6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING EQUIPMENT OR CULTIPACK AFTER SEEDING. 7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. IF STAND SHOULD BE OVER 60% DAMAGED REESTABLISH FOLLOWING ORIGINAL LIME, FERTILIZER AND SEEDING RATES. 9. CONSULT CONSERVATION INSPECTOR ON MAINTENANCE TREATMENT AND FERTILIZATION AFTER PERMANENT COVER IS ESTABLISHED. * APPLY: AGRICULTURAL LIMESTONE — 2 TONS /ACRE OR 3 TONS /ACRE IN CLAY SOILS FERTILIZER — 1000 LBS /ACRE (10- 10 -10) SUPERPHOSPHATE — 500 LBS /ACRE (20 %) MULCH — 2 TONS /ACRE (SMALL GRAIN STRAW)ANCHOR — ASPHALT EMULSION AT 450 GAL. /ACRE SEAL ... �M,, 0 ''', 036348 C., 04/17/2015 SEEDBED PREPARATION NTS v qKM&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233 -8091, Fax: (919)233 -8031 F -1222 www.mckimcreed.com 1. PREPARE SOIL BEFORE INSTALLING ROLLED EROSION CONTROL PRODUCTS (RECPS), INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. 2. BEGIN AT THE TOP OF THE SLOPE BY ANCHORING THE RECPS IN A 6" (15 CM) DEEP X 6" (15 CM) WIDE TRENCH WITH APPROXIMATELY 12" (30 CM) OF RECPS EXTENDED BEYOND THE UP -SLOPE PORTION OF THE TRENCH. ANCHOR THE RECPS WITH A ROW OF STAPLES /STAKES APPROXIMATELY 12" (30 CM) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" (30 CM) PORTION OF RECPS BACK OVER SEED AND COMPACTED SOIL. SECURE RECPS OVER COMPACTED SOIL WITH A ROW OF STAPLES /STAKES SPACED APPROXIMATELY 12" (30 CM) APART ACROSS THE WIDTH OF THE RECPS. 3. ROLL THE RECPS (A.) DOWN (FOR SLOPES 3:1 OR GREATER) OR (B.) HORIZONTALLY (FOR SLOPES LESS THAN 3:1) ACROSS THE SLOPE. RECPS WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL RECPS MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES /STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING THE DOT SYSTEM TM, STAPLES /STAKES SHOULD BE PLACED THROUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN. 4. THE EDGES OF PARALLEL RECPS MUST BE STAPLED WITH APPROXIMATELY 2" -5" (5 CM -12.5 CM) OVERLAP DEPENDING ON RECPS TYPE. 5. CONSECUTIVE RECPS SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END (SHINGLE STYLE) WITH AN APPROXIMATE 3" (7.5 CM) OVERLAP. STAPLE THROUGH OVERLAPPED AREA, APPROXIMATELY 12" (30 CM) APART ACROSS ENTIRE RECPS WIDTH. NOTE: *IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6" (15 CM) MAY BE NECESSARY TO PROPERLY SECURE THE RECPS. A FLOW TEMPORARY STABILIZATION FOR SLOPES GREATER THAN 10 FEET NTS 4.0' MATTING J ..TH NATIVE GRASSES_AT TIME OF INSTALLATION 1.0' 1' TUCK EACH SIDE — CLASS B RIPRAP 6" CABC FILTER FABRIC X0000 Do Lo W DEPTH ©0 N0. (IN.) (FT.) (FT.) (IN.) CLASSIFICATION HW —BPD -6 18 BRIAR-7SKCHAPEL'� by Newland COMMUNITIES RIPRAP TO EXTENE TOP ( B do SILT FENCE TO I INSTALLED OVI TOP OF FI SILT FENCE crrmnki 0 D CHANNEL BOTTOM OUTLET Do Lo W DEPTH LINING N0. (IN.) (FT.) (FT.) (IN.) CLASSIFICATION HW —BPD -6 18 9.0 5.0 22 CLASS B HW— BPD -11 18 9.0 5.0 22 CLASS B STONE CLASSIFICATIONS OF CLASS B REQUIRE A SUBLAYER OF FILTER FABRIC OR FS -2 FILTER STONE WITH A BEDDING THICKNESS OF 6 ". BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA EROSION AND SEDIMENTATION CONTROL DETAILS RIPRAP OUTLET PROTECTION NTS r DATE: -144 APRIL 17, 2015 MCE PROS. # 02735 -0113 D RAW N BSS DESIGNED BSS CHECKED GCA PROS. MGR. CHS SCALE MBC FILE NUMBER D1.X HORIZONTAL: DRAWING NUMBER 1" = 50' VERTICAL: D1.2 N/A STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY 1 GUARDRAIL TO BE USED WHERE TOE OF SLOPE IS GREATER THAN 5' GRADE DIFFERENTIAL FROM TOP OF SHOULDER EXISTING GROUND Z/ MUL. -MUL.; 4U N'UMLIL, K /VV NOT TO SCALE EXISTING SEWER LINE SHALL BE DUCTILE IRON 10' EITHER SIDE OF CROSSING 4 d 4 A a 4 4 4 a 4 a d a. CONCRETE ENCASEMENT IF SEPARATION LESS THAN 18" WATER MAIN SHALL BE DUCTILE IRON 10' EITHER SIDE OF CROSSING UNDERGROUND SERVICE ALERT PAVEMENT SCHEDULE 1/8" RAD. SURFACE CHATHAM COUNTY C1 AT AN AVERAGE RATE OF 110 LBS. PER SQ. YARD. DESIGNED PUBLIC UTILITIES & WATER DIVISION $ Inlxi9EE WATER AND SEWER O8" P.O. D PmI1IBaH0. NO 2 7312 O30" CROSSING OCOMPACTED EAST STREET, SUITE 26a .L 1 xo'-'¢ z H°c 9 EMPERORS, NO 27312 CH�A,,.T"H"AM�COU.,N..TY a 9" X 12" OR 18" T o CONCRETE CURB Tlfq WgRffiT9 DAYS HESDR@ YOU DIG SEAL 1 ISSUED FOR PERMITTING 2015.04.17 REV. NO. DESCRIPTIONS DATE REVISIONS SEAL AL__ 036348 C'•, 04/17/2015 ENGINEER.• �Q�•\\. 111111 \ 0�\\\\ X2'1 EXISTING GROUND _ VARIOUS PRIVATE UTILITIES (BOTH SIDES) .,..,.CRETE SIDEWALK DIP WATER MAIN (3.5' MIN. COVER) v v ED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233 -8091, Fax: (919)233 -8031 F -1222 www.mckimcreed.com BRIAR-7SKCHAPEL'� by Newland COMMUNITIES v v E" H � cl) Z Err 2, -Orr D H p %2" RAD. z = D 3" RAD. i�rr RAD. = -nDDm o H c�D I 2' -6" D D CD 2' -6" CURB AND GUTTER 0 RAD. 9 9 3/4 If RAD. c`')I 1/g„ RAD. �2t 1341, RAD. V-6" ° 1' -6" CURB AND GUTTER 4' -0" PROPOSED 2' -0" 2' -O" EDGE OF PAVEMENT 6„ 8" X 12" OR 18" CONCRETE CURB PAVEMENT PAVEMENT SCHEDULE 1/8" RAD. SURFACE 1.0" SF9.5A ASPHALT SURFACE COURSE C1 AT AN AVERAGE RATE OF 110 LBS. PER SQ. YARD. DESIGNED 2.0" 59.56 ASPHALT SURFACE COURSE D1 AT AN AVERAGE RATE OF 224 LBS. PER SQ. YARD. O8" COMPACTED ABC STONE BASE COURSE O30" CURB AND GUTTER OCOMPACTED SUBGRADE X2'1 EXISTING GROUND _ VARIOUS PRIVATE UTILITIES (BOTH SIDES) .,..,.CRETE SIDEWALK DIP WATER MAIN (3.5' MIN. COVER) v v ED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233 -8091, Fax: (919)233 -8031 F -1222 www.mckimcreed.com BRIAR-7SKCHAPEL'� by Newland COMMUNITIES v v E" H � cl) Z Err 2, -Orr D H p %2" RAD. z = D 3" RAD. i�rr RAD. = -nDDm o H c�D I 2' -6" D D CD 2' -6" CURB AND GUTTER 0 RAD. 9 9 3/4 If RAD. c`')I 1/g„ RAD. �2t 1341, RAD. V-6" ° 1' -6" CURB AND GUTTER 4' -0" PROPOSED 2' -0" 2' -O" EDGE OF PAVEMENT 6„ 8" X 12" OR 18" CONCRETE CURB PAVEMENT z cn 1/8" RAD. SURFACE 02735 -0113 D RAW N Q DESIGNED HLr�C) CHECKED LL _j 6- z oocf3x .a• LuQzLL - 1" RAD. ciHLLO_j :. v p .:.• xo'-'¢ z H°c 9 N HH a 9" X 12" OR 18" T o CONCRETE CURB 2" RAD. 2' -0" o•,a• 4; y 8" 2' -4" MIN. 1/18 RADIUS cn 1/" in 1' -0" 1' O" 12rr v'•':r� _ 171 O [.j4 , • . .. p7" ' O D: r 111 p = EXPRESSWAY GUTTER SHOULDER B mcf) o SECTION VIEW OF CURB C D Ao v GENERAL NOTES: Im ) v -PLACE CONTRACTION JOINTS AT 10' INTERVALS, EXCEPT THAT C x A 15' SPACING MAY BE USED WHEN A MACHINE IS USED OR WHEN M� SATISFACTORY SUPPORT FOR THE FACE FORM CAN BE OBTAINED C Z WITHOUT THE USE OF TEMPLATES AT 10' INTERVALS. o -JOINT SPACING MAY BE ALTERED IF REQUIRED BY THE ENGINEER. - CONTRACTION JOINTS MAY BE INSTALLED WITH THE USE OF O TEMPLATES OR FORMED BY OTHER APPROVED METHODS. v CONSTRUCT NON- TEMPLATE FORMED JOINTS A MIN. OF 11/2" DEEP. -FILL ALL CONSTRUCTION JOINTS, EXCEPT IN 8 "x6" MEDIAN CURB, WITH JOINT FILLER AND SEALER. -SPACE EXPANSION JOINTS AT 90' :INTERVALS AND ADJACENT TO ALL RIGID OBJECTS. .01 v vM H a H• z cn -n cp LPN z = -I = -n>>m =CtaMC7 Z"-u _n C? A> n -t z i M z Z 1'e r .. CD C0Nx No Q Ui Icy z >> zzZv i D ° .'✓v7 N 6 ¢ //Z/�M v v ITT H � rcj)op 0m 4 H z -, V x--n ro,,m = c" 0 0 z H 'u I- -n ) C:> •pa cl) O F. z h MEEII M z zz im C V co ♦t=n^ yV ~ =rnz v z > E") > mom° r ° H CA is 0 M "n Nz SHOULDER WIDTH I SEE ROTE i HORIZONTAL AND VERTICAL CLEARANCES D I r TYPICAL SIGN SHAPES AND COMBINATIONS 1„ LLI GUTTER 81r z H LU 8" CD X 6" MEDIAN CURB VALLEY GLITTER Q H CC )R CURBS AND GUTTERS o m 0 OG ad cr- FILL 3/8" x 1" DEEP 0 Cc GROOVED OR SAWN z JOINT WITH JOINT Q W SEALER JOINT SEALER cf) W 1/8" RAD. GUTTER = D: G 1/8" RAD• PAVEMENT SURFACE H v z ­. SURFACE ZO Q CD C4 LU )POSED 1B & GUTTER PROP. 1/2" JOINT FILLER JOINT PAVEMENT LONGITUDINAL JOINT TRANSVERSE EXPANSION JOINT IN CURB AND GUTTER SECTION VIEW OF JOINTS SHEET 1 OF 1 room 11 •I■ all 11 11 11 i N -.•. I E � � 1. -� 1 TOP TOP a" TYP SIDE SIDE TYPE "D" SIGN 2" TYP —r T" TTP TYPE *F" SZCaW TYPE "0" & "E" SIGN BACK -TO -BACK CS8 GING MOUNT Y" TYP RO RAC FRAMING AND CROSS BRACE DETAILS FOR COMBINATION TYPE "D" & "E" SIGNS FRAMING AND CROSS BRACE DETAILS WIDE SIDE OF CROSS BRACE GOES TO BACK OF SIGN FOR COMBINATION TYPE "D" & "F" SIow WIDE SIDE OF FLANGE TO BACK OF '•F" SIGN NOTES: 1. ERECT TYPE "D ", "E ", AND "F" SIGNS ON FREEWAYS WITH THE NEAR EDGE OF THE SIGN 20 FT. FROM THE TRAVEL LANE. ERECT ALL OTHER "D ", "E ", AND F" SIGNS WITH THE NEAR EDGE OF THE SION AT THE EDGE OF THE SHOULDER BREAK (B FT. MINIMUM CLEARANCE, 12 FT. DESIRABLE, FROM THE EDGE OF TRAVEL LANE), OR AS DIMENSIONED ON PLAN SHEETS. 2. ERECT TYPE "D ", "E ", AND "F" SIGNS WITH THE BOTTOM OF SIGN ASSEMBLY AT LEAST 7 FT. ABOVE THE EDGE OF THE TRAVEL LANE ON ROADS WITH 2 OR MORE LANES AND AT LEAST 5 FT. ON OTHER ROUTES. THE VERTICAL CLEARANCE IS 7 FT. WHERE REQUIRED FOR PEDESTRIAN TRAFFIC AND /OR PARKED VEHICLES. S. THE VERTICAL. DIMENSION BETWEEN MOUNTING HOLE CENTERS ON ALL TYPES "D ", "E ", AND "F" SIGNS IS SO" MAXIMUM. THE VERTICAL AND HORIZONTAL DIMENSIONS BETWEEN MOUNTING HOLES IS TO THE WHOLE INCH. EACH SIGN PANEL HAS A MINIMUM OF 2 DOLTS PER SUPPORT. 4. ATTACH SIGN W/ 91@" HEX HEAD BOLT, NYLON WASHER, SHIM, FLAT WASHER, LOCK WASHER, HEX AUT NO SUCKLING OF THE SIGN WILL BE PERMITTED. SEE ASSEMBLY DETAIL SHEET# 2 OF 504.54. 5. FURNISH AND INSTALL CROSS- BRACING AS SHOWN IN DETAIL. PAINT ENDS OF ONES BRACES W/ APPROVED. ZINC PAINT S. INSTALL POST AND CROSS - BRACING WITH THE WIDE SIDE OF THE FLANGE TOWARD THE BACK OF SIGN($) FOR COMBINATION TYPE "O" AND "F" SIGNS. 7. THE SHIELD HEIGHTS IN THESE ASSEMBLIES CAN NOT BE LARGER THAN 24 ". 36 "X 36" SIGN 30 "X 30" SIGN >-t 24 "X 24" SIGN 48 "X 48" SIGN 1 18"1 ,"12" - - -1 1� ",12„ TYPE "E" SIB 1 � I 115" 'A' � I� H > 20„ S F - ---ir 3" 2" ��_���-- r-- - --� -- ,TYPE I I „ "E” AND "F " SD" MAX I I H i SIGNS i MAX TYPE "D" 5IM5 I I I I 1 --t-----t-- f- ---f —3"2" UNITS ON ATTACHED SHEET *MINIMUM 4 FT. BETWEEN CHANNEL POSTS — H 5 is" 2 POST VALIDATION STICKER 1 POST SUPPLIED BY SIGN PLANT "U" ROWEL POST 12" OlA.IN1U,ID OR 900MIE SMOOTH HALL HMO DSIU.ED tXRiEO, FDIMED OR .. HNME.6 AND BARW FILLED 2" JOINT SEALER WITH SOIL. PAVEII�IT DETAIL FOR INSTALLATION OF CHANNEL POST IN CONCRETE BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA NCDOT ROADWAY DETAILS 5/18" HEX HEAD HOT DIPPED OALV"UED OLT SION FACE - V ALUMINUM SHIM SACK OF SIGN "U" GHNINEL POST LOCK T"HER ASSEMBLY DETAIL DATE: APRIL 17, 2015 MCE PROS. # 02735 -0113 D RAW N BSS DESIGNED BSS CHECKED "WIMEAMIZEEME PROS. MGR. CHS UNITS ON ATTACHED SHEET *MINIMUM 4 FT. BETWEEN CHANNEL POSTS — H 5 is" 2 POST VALIDATION STICKER 1 POST SUPPLIED BY SIGN PLANT "U" ROWEL POST 12" OlA.IN1U,ID OR 900MIE SMOOTH HALL HMO DSIU.ED tXRiEO, FDIMED OR .. HNME.6 AND BARW FILLED 2" JOINT SEALER WITH SOIL. PAVEII�IT DETAIL FOR INSTALLATION OF CHANNEL POST IN CONCRETE BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA NCDOT ROADWAY DETAILS 5/18" HEX HEAD HOT DIPPED OALV"UED OLT SION FACE - V ALUMINUM SHIM SACK OF SIGN "U" GHNINEL POST LOCK T"HER ASSEMBLY DETAIL DATE: APRIL 17, 2015 MCE PROS. # 02735 -0113 D RAW N BSS DESIGNED BSS CHECKED GCA PROS. MGR. CHS .01 z o� �< Q H cc OCD LL_ o� =z =z ��a0 ZLU H � cc 0 z Cr • E- H 1 W° Io cc O ..I LL z z M N 3W- d J = co 0 W aN�� FZ" .� con- 3 H a G1 0 J 0 W R,�� IMMM • • s tI) z 0 co ca � M ca N R- " . U. LL IL 0 r v C5 D W z z z W � x �IC1� H .. ~ -L W z &a W SCALE MBC FILE NUMBER D2.X HORIZONTAL: DRAWING NUMBER N/A VERTICAL: D2.1 N/A STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY � v vm N 0 H' Z -n cf) �0m --1 m z =--I H D = -ZDm x 0 O ° ZHOr �I C) 1 > _< --I H co Z n ao 3 m CA m aZ c� Z r vCD x co a__j Ov D _ CA v r v H N z 0 v 0 a I m N SHEET 1 OF 1 840.24 4'-0" 3/ m t� N x Y 0 NI ` L X X _ N if .A NI o N N 1L 0 � Y� PLAN GRATE SECTION Y -Y 1" 1" I 1n N M\ - r CV C\ 1' -11" 7 GRATE SECTION X -X 3' -10%2" f � 4' - 0'r FRAME SECTION X -X GRATE SECTION X -X N 1'- 111/4" 2'- 03/411 FRAME SECTION X -X 1 ISSUED FOR PERMITTING 2015.04.17 REV. NO. DESCRIPTIONS DATE REVISIONS NOTE: SEE STD. DWG. 840.25 ISHEET 1 OF 1 FOR FRAME ANCHORAGE. 840.24 SEAL v vm N H' Z =CAOO � 0 1 mz =� H D = -ZDm x 0 O ° z1�Or-TI nD>> C/) C) O z 0 O z C'1 m 1 m mZ I7 O r = N �m� x v z ova M� rn O v D � z � M r z m 0 m _< x m v SHEET 1 OF 1 840.19 v 0 rO O ° 0�I�CD m z = -� =�DDm = CA 0 O z-0 rm • 0 O ,.., �DDD 00 �0 I: ' Z -11 0 m 7° z C O o r m m N/,., V/ O v = Z 0 DaZ v 0 m > N v y Z D 1v* = z _ ° O o CD S �v Z PLAN FRAME AND GRATES TOF A -s„ 61, 4" -.W 4" LET PIPE 3„ SEE NOTE SECTION X -X PIPE z Oo 21/411 HEIGHT �a Q ��(0 LLJOH GENERAL NOTES: D A USE CLASS "B" CONCRETE THROUGHOUT. H Q Q a Z 000x H MIN. TOTAL Q 3 1 % " H ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. - �"� ° LL s 211 O O 12" CENTERS AS DIRECTED BY THE ENGINEER. 0.753 H LU oHLL O_j �°1""1Q 11/2 N r N 2' -0" 1' -11" z 1°-1 IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF AS SHOWN ON STD. NO. 840.00. BOX, ADD TO SLAB Q IO-I 0.023 0.036 W N CL 1,-1 T W O 1 c� \ N� MAX. DEPTH OF THIS STRUCTURE FROM TOP OF BOTTOM SLAB TO TOP ELEVATION T ° IS 12 FEET. 0.033 N FOR 3/8" DIA. BOLT N CL F-1 H 2' -8" T W ° a FRAME SECTION Y -Y T ° 0.059 CHAMFER ALL EXPOSED CORNERS 1 ". DRAWING NOT TO SCALE. 0 LL 2' -0" 3' -2" �a 0 0.782 1.144 3/ 11 Y rr 4 CL � F- ¢ O ° J 3' -8" I I 0.906 1.268 N 0.178 H W w Dom O 1 /2 0 °C 3 X 0 D X 11/2"R R /B 11 2' -11�/4 " „ z Q Yr * CHAMFER ALL CORNERS 1" OR HAVE A RADIUS OF 1 ". 134" SECTION A -A 1 /211 7Z, 8" O.C.(TYP.) O TYPE - F 0 0.887 SHEET 2 OF 2 Z 840.03 0 2' -2" LU C 0 3' -9" Y- J Ne SIDE Za AT B" CTS. THE CONTRACTOR WILL HAVE THE OPTION TO INCREASE THIS BAR SIZE AS NEEDED. = w N PLAN W 0.235 1.001 cc 0.085 30" LL 1 ISSUED FOR PERMITTING 2015.04.17 REV. NO. DESCRIPTIONS DATE REVISIONS NOTE: SEE STD. DWG. 840.25 ISHEET 1 OF 1 FOR FRAME ANCHORAGE. 840.24 SEAL v vm N H' Z =CAOO � 0 1 mz =� H D = -ZDm x 0 O ° z1�Or-TI nD>> C/) C) O z 0 O z C'1 m 1 m mZ I7 O r = N �m� x v z ova M� rn O v D � z � M r z m 0 m _< x m v SHEET 1 OF 1 840.19 v 0 rO O ° 0�I�CD m z = -� =�DDm = CA 0 O z-0 rm • 0 O ,.., �DDD 00 �0 I: ' Z -11 0 m 7° z C O o r m m N/,., V/ O v = Z 0 DaZ v 0 m > N v y Z D 1v* = z _ ° O o CD S �v Z PLAN FRAME AND GRATES TOF A -s„ 61, 4" -.W 4" LET PIPE 3„ SEE NOTE SECTION X -X SEE DETAIL 6 4" SEALANT 1„ 4" 0 CONCRETE APRON I� LLH 1 EXPANSION Z J W 6 "\ B 6" CLASS "B" MATERIAL 1--1 CL CONCRETE CONCRETE 1Z`I H AN H R BAR < CL Orr I f OUTLET PIPE ° C m DETAIL D°C c) SEE NOTE 6 (APRON SUPPORT NOTCH) MAX. PIPE THIS SIDE - 18" z SECTION Y -Y < W O DITCH GRADE I2 N T - _ - ~ I 1 I - - - _ J LH 1 - r_ - - I #4 BAR Z W I I I IONS N W W PIPE I I I I I I I r�GRATEO D.I. MINIMUM DIMENSIONS AND QUANTITIES FOR CONCRETE GRATED DROP INLET PIPE z WIDTH HEIGHT CUBIC YARDS OF CONCRETE IN BOX GENERAL NOTES: D A USE CLASS "B" CONCRETE THROUGHOUT. H Q Q H PER FT. HT. H MIN. TOTAL Q 3 PROVIDE ALL DROP INLETS OVER 3' -6" IN DEPTH WITH STEPS 12" H ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. FZ-1 0 0 . OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT LL JO C- = Z 12" CENTERS AS DIRECTED BY THE ENGINEER. 0.753 Cn USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. 15" W Q LL Q x 2' -0" 1' -11" V ° IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF AS SHOWN ON STD. NO. 840.00. BOX, ADD TO SLAB Q IO-I 0.023 0.036 W CONSTRUCT WITH PIPE CROWNS MATCHING. 2' -0" N ~ LL ° J ° MAX. DEPTH OF THIS STRUCTURE FROM TOP OF BOTTOM SLAB TO TOP ELEVATION O In IS 12 FEET. 0.033 Z , j USE STANDARD FRAMES AND GRATES 840.22 (SHOWN), 840.24(SHOWN), 840.20, N CL F-1 840.29, AND 840.33. 2' -8" T W ° SEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATES NOT SHOWN. T ° 0.059 CHAMFER ALL EXPOSED CORNERS 1 ". DRAWING NOT TO SCALE. 3' -8" 2' -0" 3' -2" 0.362 0 0.782 1.144 W 0.127 CONCRETE APRON CL SEE DETAIL 6 4" SEALANT 1„ 4" 0 CONCRETE APRON I� LLH 1 EXPANSION Z J W 6 "\ B 6" CLASS "B" MATERIAL 1--1 CL CONCRETE CONCRETE 1Z`I H AN H R BAR < CL Orr I f OUTLET PIPE ° C m DETAIL D°C c) SEE NOTE 6 (APRON SUPPORT NOTCH) MAX. PIPE THIS SIDE - 18" z SECTION Y -Y < W O DITCH GRADE I2 N T - _ - ~ I 1 I - - - _ J LH 1 - r_ - - I #4 BAR Z W I I I IONS N W W PIPE I I I I I I I r�GRATEO D.I. MINIMUM DIMENSIONS AND QUANTITIES FOR CONCRETE GRATED DROP INLET PIPE SPAN WIDTH HEIGHT CUBIC YARDS OF CONCRETE IN BOX DEDUCT FOR ONE D A B H BOTTOM SLAB H PER FT. HT. H MIN. TOTAL TOTAL C.S. R. C. 12" 3' -8" 2' -0" 1' -8" 0.362 0.247 0.391 0.753 0.020 0.032 15" 3' -8" 2' -0" 1' -11" 0.362 0.247 0.453 0.815 0.023 0.036 18" 3' -8" 2' -0" 2' -2" 0.362 0.247 0.515 0.877 0.033 0.049 24" 3' -8" 2' -0" 2' -8" 0.362 0.247 0.659 1.021 0.059 0.085 30" 3' -8" 2' -0" 3' -2" 0.362 0.247 0.782 1.144 0.092 0.127 36" 3' -8" 2' -0" 3' -8" 0.362 0.247 0.906 1.268 0.132 0.178 43" NOTE: USE TYPE "E" "F" AND "G" GRATE UNLESS OTHERWISE NOTED. eeM t A ALIGN FRAME "IE j EDGE OF WAL 1 FOR VERTICA SECTION - BB �6 rr %6 14 1 � = 6" 6" 3�21r 3,_011 3W SECTION - KK I./ J C�M1id Lem- L LI► M J FRAME PLAN 3'-0�err R IF if- ir- - 1 Err 1/2 " aaLLrr r T 21XB" SECTION - LL -� i+r T� T SECTION - PP N m ` of K N N M 1k6" I-�- 21_11It R HOOD ELEVATION DOWEL "A" SHEET 1 OF 1 840.19 N SECTION - JJ 5� 31 R n --T1, r'� i � n 112 rr 4�rr SECTION - RR c r 0 ° o n ° to CC W U) 0 Z 'S n O 1-1 W W z W LL CI: 0 LL v m H z D H O 00 21- 1134(11 „ 2 " 1� �Q P� P B LL Jd1 --1z m z = � y __ o o TYPE "G" TYPE "E" TYPE "F" A A 1 "� I 9 %g" 00 cn zOO�TI 6" E #8 "W" BARS #4 BAR "V" t` a) J 000x -� WATER FLOW - SAG �- WATER FLOW �- T - T I9 %g" r LL0 1--1 z O 10-1 >� < 21 " LL W QQLL x <00 N N H U) ~LLOJ seCTION - W cc: 0 O , Q °C T CL W ° T ° z 1-+ NO. m a z - - - - - - - - - - - - - - - - - - - - - - - LIJ LBS. �� r U O (y 1 SECTION B -B SECTION- NN m0 4 `I 111 21/" 2' -9" *i 11 E WATER FLOW SAG WATER FLOW �- H 0= °pQ 1z-1 0 O O Q cn -- = m LL = DD m m Vw r Z N SECTION - JJ 5� 31 R n --T1, r'� i � n 112 rr 4�rr SECTION - RR c r 0 ° o n ° to CC W U) 0 Z 'S n O 1-1 W W z W LL CI: 0 LL v m H z D H O DETAIL SHOWING TYPES OF GRATES USE ACCORDING TO WATER FLOW. 21- 1134(11 „ 2 " 1� z 0 Q Q , z x v °��� DEDUCTIONS ONE PIPE B LL Jd1 --1z m z = � y __ o o TYPE "G" TYPE "E" TYPE "F" A A 1 "� I 9 %g" 000x Q v CC 0 H cn zOO�TI 6" E #8 "W" BARS #4 BAR "V" cT a) J D D -� WATER FLOW - SAG �- WATER FLOW �- T - T I9 %g" r LL0 1--1 z O 10-1 >� < B 4 = C7 v '> N 91� 0 0 - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B I 14 T CL W ° T ° 00 NO. m a z - - - - - - - - - - - - - - - - - - - - - - - �� LBS. �� r U O (y 1 SECTION B -B T -0" m0 - - - - - - - - - - �' - - - - - - - - - - - • - - - - - - 111 21/" 2' -9" m v z E WATER FLOW SAG WATER FLOW �- -- 1z-1 0 O O Q cn -- SECTION A -A LL = DD m m Vw 0.235 ° z = CO TYPE "F" TYPE "E" TYPE "G" TYPE - E Z Q cn D z D O a o°C 6.00/6.75 9 RAIS �F HOWH RROW r � 23/4 g z x D N ARROW " RAISED FLOW 2 %6 HIGH � _ D � LLI Q z * PIPE TO BE GROUTED INTO HEADWALL AT JOB SITE BY o O cl rr T Q�ca~n D Z D 1 \\p 1 /¢" 11 1 - =� o 0 z x w O x 1 �g Q /g" � H W w Dom O 1 /2 1 II �" 4 - �? cn v x z 1 /211 13/ '-►I 1/g 11 2- 113,4/1 1 p /2'�i H� � H 4u- 11/2"R R /B 11 2' -11�/4 " „ w � o LL * CHAMFER ALL CORNERS 1" OR HAVE A RADIUS OF 1 ". 134" SECTION A -A 1 /211 7Z, 8" O.C.(TYP.) 7.25/9.25 TYPE - F ] TYPE G SECTION A -A 0.887 SHEET 2 OF 2 SHEET 2 OF 2 840.03 840.03 SEAL � ?RO , �p ... FESS /O,yq !x'1'9 AL 036348 C., 04/17/2015 ENGINEER.• �Q�•\\. v v qKM&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233 -8091, Fax: (919)233 -8031 F -1222 www.mckimcreed.com BRIAR�CHAPEL'� Ln. MJ, Newland 60MMUNrnES v 0 N -0 H' Z �N O O 0 1 m m =� 1­4 = -DDm x 0 O ° ZHOr-TI �DDD -� C< I: A c' O Z m n z O r- z� 1 N n x m cn =mz c 0 > _ 41 -1 v =n v D m N z c� m z 0 SHEET 1 OF 2 840.02 BACK OF CURB X„ o. o. . o. Y v A:. m PLAN X SECTION Y -Y RISER HT. VARIES 11 .a 6„ TIE vD WHERE 30" TO 36" PIPE IS USED RISER HT. VARIES .o . WHERE 42" TO 54" PIPE IS USED DETAIL SHOWING METHOD OF RISER CONSTRUCTION v 0 F1� S� DOO Ell- CD 7o I m z --1 #4 BARS "V" H � D @ EQUAL SPACES =cz >m 31r� irr x 0 O ° ZH -r„ O n� I> R CA 0O Z El PLAN OF TOP SLAB CENERAL NOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL CATCH BASINS OVER 3' -6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. USE TYPE "E ", "F" AND "G" GRATES UNLESS OTHERWISE INDICATED. FOR 8' -0" IN HEIGHT OR LESS USE 6" WALLS AND BOTTOM SLAB. OVER 8' -0" TO 16' -0" IN HEIGHT USE S" WALLS AND BOTTOM SLAB. ADJUST QUANTITIES ACCORDINGLY. CONSTRUCT WITH PIPE CROWNS MATCHING. CHAMFER ALL EXPOSED CORNERS 1 ". DRAWING NOT TO SCALE. SECTION X -X F7-4 B T:9: • °6 s" c 6" D p. I o .s 6„ T vo P o 0 oo. v. T SECTION J -J WHERE 30" TO 36" PIPE IS USED SEE NOTE or .:. . 6� I I R C" - LU p � `n Q LL 0 � w SECTION S -S m DIMENSIONS OF BOX AND PIPE Z z O r- DEDUCTIONS ONE PIPE z SPAN //H� 1 0 CD WIDTH N m x MIN. HEIGHT = m 0 =-1 --1 D 6" E #8 "W" BARS #4 BAR "V" m @ EQUAL SPACES Z BOTTOM SLAB cC>D m v B 4 = C7 v #4 BARS "U" 111 =m E F SECTION R -R 00 NO. m a z NO. N 0 LBS. �� r U O (y z T -0" 2' -2" -- -- 2' -9" -- -- -- 0 JD SHEET 2 OF 2 840.02 v 0 H� N' Z 70000 r0-I Ln m z = D = -nDDm =fA00 zH -0 r_1 • 00H n>> _< --I I. 0 O Z T m w�oz M 0�� m N = 1 i o N v m z D c C N m O -0 m m F-1 Z z v �' CD o = m r SHEET 1 OF 1 838.81 L #4 BAR F d DOWEL PLAN f SECTION M -M WHERE 42" TO 54" PIPE IS USED J M o' p o o M z -A PLAN 1 "p. el PLAN EXPANSION JOINTS STD. 840.03 FRAME, GRATE 8 HOOD " PLAN CURB AND GUTTER WITH CATCH BASIN ON STEEP GRADES TOP USE ON FLAT ELEV. EXPANSION JOINT GRADES 2% AND UNDER 3 0 I I ,_n DEPRESSED GUTTER LINE EXPANSION JOINT m ELEVATION NORMAL CURB AND GUTTER ON LIGHT GRADES NORMAL GUTTER LINE EXPANSION JOINT B' TOP USE ON GRADES OVER 2% ELEV. I -10 I DEPRESSED GUTTER LINE EXPANSION JOINT 6 0' 1' -0" MAX. ELEVATION NORMAL CURB AND GUTTER ON STEEP GRADES MINIMUM DIMENSIONS AND QUANTITIES FOR CONCRETE CATCH BASIN(BASED ON MIN. HEIGHT, H, WITH NO RISER) DIMENSIONS OF BOX AND PIPE COVER DIMENSION z CU.YDS. CONC. IN BOX DEDUCTIONS ONE PIPE PIPE SPAN WIDTH WIDTH SPAN MIN. HEIGHT BARS -U BARS -V BARS -W TOTAL TOP SLAB BOTTOM SLAB TOT. CONC. OH HT. HUM HEIGHT H D A B C G H E F NO. LENGTH NO. LENGTH NO. LENGTH LBS. FOR IN ACCORDANCE WITH SPECIFICATION SECTION 838. r U O (y 12" T -0" 2' -2" -- -- 2' -9" -- -- -- -- -- -- -- -- -- -- 0.235 0.772 0.015 0.026 15" 3' -0" 2' -2" N 1' fL-1 -1 6.00/6.75 3' -0" OSHA STANDARD 1926.704. r W ° H1 I #5 @ 811 * PIPE TO BE GROUTED INTO HEADWALL AT JOB SITE BY T ° I fD 6.50/6.75 CONTRACTOR 4.5 0.235 0.829 0.023 0.036 18" 3' -0" 2' -2" #5 @ B" 34 A 3' -3" AS LONG AS THE SAME AREA OF STEEL IS PROVIDED. 7.25/9.25 13.75/15.75 5.5 * CHAMFER ALL CORNERS 1" OR HAVE A RADIUS OF 1 ". 4.50/5.00 611 8" O.C.(TYP.) 7.25/9.25 14.00/15.75 0.235 0.887 0.033 0.049 24" 3' -0" 2' -2" LU 3' -9" NOTE: THE MINIMUM BAR SIZE SHALL BE #5 BARS J Ne SIDE AT B" CTS. THE CONTRACTOR WILL HAVE THE OPTION TO INCREASE THIS BAR SIZE AS NEEDED. = a O 0.235 1.001 0.059 0.085 30" 3' -0" 2' -2" 3' -4" 4' 3" 1' -2" 4' -0" 4 1' -5" 2 3' -9" 3 3' -9" 39 0.123 0.321 1.433 0.092 0.127 36" 3' -0" 2' -2" 3' -10" 4' 9" 1' 8" 4' 0" 4 V -11" 3 3' -9" 3 3' -9" 43 0.161 0.358 1.714 0.132 0.178 42" 3' -0" 2' -2" 4' -5" 5' -3" V -5" 3' -2" 4 1' -8" 2 2' -11" 3 2' -11" 32 0.112 0.318 1.738 0.180 0.243 48" 3' -0" 2' -2" 5' -0" 5' -9" 2' -0" 3' -2" 4 2' -3" 3 2' -11" 3 2' -11" 35 0.145 0.352 2.052 0.235 0.317 54" 3' -0" 2' -2" 1 5' -7" 6' -3" 1 2'-7" 1 3' -2" 1 4 2' -10" 1 5 2' 11" 3 2' -11" W1 (FT.) FOR �BAR VSIZE ELEVATION PLAN 41 0.160 0.386 2.387 0.297 0.401 * RISER HAS .228 CUBIC YARDS OF CONCRETE PER FOOT HEIGHT Z O 0 �>- Q Q Q 3 H = (D LL U JaZ O x O CC O QU�OFO -1 H cf) LL 0 cc F-i O ° L7 Q z H 1 a~ Q O 2 0 z LL I--I (D U) 3 m �LL-I a c = ° V o 1�- � o0Z) Q W = � H � o W - _ N 0 T _jO Z V W HEET 1 OF 2 840.02 z 00 �Q Q ;z= LLJa1 --1Z O O 0 x CC QUccco COHLLO_j 0 °C/3 z . 1 CL LU ° x 0 Z LL I--I 0 N H cr- LO 0 � � Z Q W � 1.- 1- = = N cf) 0 F� Z J z Z w HEET 2 OF 2 840.02 ENDWALL DIMENSIONS FT. MINIMUM z MIN. /MAX. MIN. /MAX. MIN. /MAX. 00 PIPE DIA. BAR SIZE H1(FT.) Q D (FT.) W1 NOTES: 1.0 #5 @ 8" 1.25/2.00 2.00/3.75 Q�� D 6" * THIS PRECAST ENDWALL MAY BE USED FOR THE FOLLOWING STANDARDS: 838.01, 83 8.11, 838.21, 838.27, 838.33, rZ-1CC U LL _J r-1 Z 1.25/2.00 3.00/3.75 838.39, 838.51, 838.57, 838.63 AND 838.69. ° c o = Z 6.50/6.75 1.50 * INSTALL PRECAST ENDWALLS WITH WINGS AND PAY W Q LL = 1 0' 1.50/2.50 FOR IN ACCORDANCE WITH SPECIFICATION SECTION 838. r U O (y 2.0 #5 @ B" * USE 4000 PSI CONCRETE. x ~ Z W 0 1.75/2.50 4.00/4.25 * PROVIDE ALL REINFORCING STEEL WHICH MEETS ASTM A615 F- LL ° J #5 @ B" 2.50/3.50 4.00 /6.00 p 0 N 4.50/5.50 - FOR GRADE 60 AND WELDED WIRE FABRIC CONFORMING #5 @ B" 0 I 5.00 /6.00 TO ASTM A185 WITH 2" MIN. CLEARANCE. Z 1--1 11.50/11.75 H2 * PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH N 1' fL-1 -1 6.00/6.75 3.25/3.50 OSHA STANDARD 1926.704. r W ° H1 I #5 @ 811 * PIPE TO BE GROUTED INTO HEADWALL AT JOB SITE BY T ° I fD 6.50/6.75 CONTRACTOR 4.5 #5 @ 8" - ALL ELEMENTS PRECAST TO MEET ASTM C913. 3.25/4.00 - - - - 13.50/15.75 WELDED WIRE FABRIC MAY BE SUBSTITUTED FOR REBAR #5 @ B" 34 A 7.00/8.50 AS LONG AS THE SAME AREA OF STEEL IS PROVIDED. 7.25/9.25 13.75/15.75 5.5 * CHAMFER ALL CORNERS 1" OR HAVE A RADIUS OF 1 ". 4.50/5.00 611 8" O.C.(TYP.) 7.25/9.25 14.00/15.75 6.0 REFER TO CHART 4.5015.00 3 3.25/4.00 FOR BAR SIZE 14.75/16.75 LU NOTE: THE MINIMUM BAR SIZE SHALL BE #5 BARS J Ne SIDE AT B" CTS. THE CONTRACTOR WILL HAVE THE OPTION TO INCREASE THIS BAR SIZE AS NEEDED. = a O ENDWALL DIMENSIONS FT. MINIMUM MIN. /MAX. MIN. /MAX. MIN. /MAX. MIN. /MAX. MIN. /MAX. PIPE DIA. BAR SIZE H1(FT.) H2(FT.) D (FT.) W1 W2 1.0 #5 @ 8" 1.25/2.00 2.00/3.75 1.25/1.75 3.00/3.75 5.50/6.00 1.25 #5 @ 8" 1.25/2.00 3.00/3.75 1.25/2.00 3.50/3.75 6.50/6.75 1.50 #5 @ B" 1.25/2.00 3.00/4.25 1.50/2.50 3.50/3.75 6.50/6.75 2.0 #5 @ B" 1.50/2.50 4.00/4.75 1.75/2.50 4.00/4.25 7.50/8.25 2.5 #5 @ B" 2.50/3.50 4.00 /6.00 2.00/3.00 4.50/5.50 10.00/11.50 3.0 #5 @ B" 3.00/3.50 5.00 /6.00 2.75/3.50 5.25/5.75 11.50/11.75 3.5 #5 @ 811 3.25/4.50 6.00/6.75 3.25/3.50 6.00/6.75 12.00/13.25 4.0 #5 @ 811 3.50/4.50 6.50/7.00 3.25/3.50 6.50/6.75 13.00/13.25 4.5 #5 @ 8" 4.00/5.00 6.50/8.50 3.25/4.00 7.00/9.25 13.50/15.75 5.0 #5 @ B" 4.50/5.00 7.00/8.50 3.25/4.00 7.25/9.25 13.75/15.75 5.5 #5 @ B" 4.50/5.00 7.50/8.50 3.25/4.00 7.25/9.25 14.00/15.75 6.0 #5 @ 8" 4.5015.00 7.50/8.50 3.25/4.00 7.75/9.25 14.75/16.75 BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA N C D OT DRAINAGE DETAILS DATE: APRIL 17, 2015 MCE PROS. # 02735 -0113 D RAW N BSS DESIGNED BSS CHECKED GCA PROS. MGR. CHS D2.2 N/A 0) 0 3 Q L1J LU o W a ° ~ LLI N Ct n oV cc ZQ Z F- O V N x N 0 w _a0 z CD Z W U) w 0 0 LL EET 1 OF 1 138.80 SCALE MBC FILE NUMBER D2.X HORIZONTAL: DRAWING NUMBER N/A VERTICAL: D2.2 N/A STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY , 1 1/2' 3" 0 0 o 0 0 0 0 3" (TYP.) MiIIIIIII11M. Ii 5/8" x 1 1/2" 1 13/16" DIA. HOLES (TYP.) SLOTS (TYP.) 5/8" DIA. HOLES FOR LAG SCREWS (TYP.) 0 0 0 0 0 . 6" 13'18 1/4"1 8 1/4'13"1 V -1 1/2"_ 1 V -1 1/2" 3" V -1 1/2" V -1 1/2" 3" 8 1/4"18 1 /4" 3" 6" STANDARD STEEL RAIL DETAIL 699 x328 "x9' -6" NTS r. 3" (TYP.) SIDE VIEW UNCOATED ASTM A 588 STEEL 4' - 5" IN ACCORDANCE WITH ASTM A 123 1 1/2" FRONT VIEW 3 1/4" DIA. SHY LINE BEGIN FLARE EDGE OF PAVEMENT STANDARD POST SECTION STEEL BACKED TIMBER GUARDRAIL WI_12 PAY LIMITS FOR TYPE FAT -30 TERMINAL SECTION 2' — 6" POST DETAIL STEEL — BACKED STEEL SPLICE PLATE FOR GUARDRAIL LIMITS LIMITS WITH FOR GUARDRAIL WITH W6 x 15 TIMBER GUARDRAIL —7 STEEL RAIL BACKING TYPE FAT -20 TYPE FAT -30 NTS = L TERMINAL SECTION TERMINAL SECTION View A STRAIGHT SPLICE PLATE ELEVATION I I I I NTS DELINEATOR SEE GROUND LINE I I I I CONCRETE ANCHOR JIL j NOTE 2 & TABLE 1 6" x 12" x 10' ROUGH I I I I FOR TYPE FAT -20 t I CONCRETE ANCHOR 3 1 /4 SAWN TIMBER RAIL L J L J TERMINAL SECTION L J FOR TYPE FAT -30 A 1" 1 1/2" 10' (TYP.) (SEE VIEW A) TERMINAL SECTION (SEE VIEW A) ELEVATION 2' -6" 3" 300 7 1 /2" 3„ 7 1 /2" 3„ „ 3 1 1/2" O O O O 3" O O O 1 1/2T \\\L 7/8" x 1 1/4" BOLT SLOTS (TYP.) 3/4" x 2 1/4" BOLT SLOTS SPLICE PLATE DETAIL 6" x 328" x 2'- 6" NTS 6 "x 3/8" x 9'— 6" STEEL RAIL (TYP.) 6" x 3/8" x 2'— 6" STRAIGHT SPLICE PLATE 3/4" DIA. x 8" ROUND HI WITH HEX NUT & WASHER 5/6" DIA. x 6" ROUND HE WITH HEX NUT & WASHER POST CONNECTION FOR STRAIGHT SECTIONS NTS SEAL 1 ISSUED FOR PERMITTING 2015.04.17 REV. NO. DESCRIPTIONS DATE REVISIONS HOLE (TYP.) x 12" x 10' ROUGH WN TIMBER RAIL A. x 4" LAG SCREW 'ILL 3/8" HOLES :) IN TIMBER (TYP.) )OD BLOCKOUT LONG SEAL ,, ��N ... c?Rp ''% 036348 % 04/17/2015 � STRAIGHT SPLICE PLATE 3" 1 1 1/2" \- STANDARD STEEL RAIL �W6x15 STEEL POST -n1 nl -ni=ne 1" MIN. o. A EXPOSED GALVANIZING REAR VIEW POST CONNECTION ELEVATION NTS 6" `O 2 1/2' I 2' 3 1/4" N 4„ 1/2" � 1/2" 1 —4" 1/2 DELINEATOR 1" MIN. EXPOSED GALVANIZING 2' MIN. STANDARD SECTION WITH CURB NTS DELINEATOR SPACING 30' SPACE < 300' 20' (FLARE LENGTH) 50' BSS TOP OF FILL GCA PRO3. MGR. SIDE SLOPE N/A 5/$" O CARRIAGE BOLT WITH HEX NUT AND PLATE WASHER BLOCK, TYPE A ONLY — - - — r. IB LARE RATE =A:B I— — — A N SHY LINE SEE ROADWAY TYPICAL OFFSET SECTION FOR OFFSET D I STNAC E WI_12 PAY LIMITS FOR TYPE FAT -30 TERMINAL SECTION 2' — 6" POST DETAIL STEEL — BACKED STEEL SPLICE PLATE FOR GUARDRAIL LIMITS LIMITS WITH FOR GUARDRAIL WITH W6 x 15 TIMBER GUARDRAIL —7 STEEL RAIL BACKING TYPE FAT -20 TYPE FAT -30 NTS = L TERMINAL SECTION TERMINAL SECTION View A STRAIGHT SPLICE PLATE ELEVATION I I I I NTS DELINEATOR SEE GROUND LINE I I I I CONCRETE ANCHOR JIL j NOTE 2 & TABLE 1 6" x 12" x 10' ROUGH I I I I FOR TYPE FAT -20 t I CONCRETE ANCHOR 3 1 /4 SAWN TIMBER RAIL L J L J TERMINAL SECTION L J FOR TYPE FAT -30 A 1" 1 1/2" 10' (TYP.) (SEE VIEW A) TERMINAL SECTION (SEE VIEW A) ELEVATION 2' -6" 3" 300 7 1 /2" 3„ 7 1 /2" 3„ „ 3 1 1/2" O O O O 3" O O O 1 1/2T \\\L 7/8" x 1 1/4" BOLT SLOTS (TYP.) 3/4" x 2 1/4" BOLT SLOTS SPLICE PLATE DETAIL 6" x 328" x 2'- 6" NTS 6 "x 3/8" x 9'— 6" STEEL RAIL (TYP.) 6" x 3/8" x 2'— 6" STRAIGHT SPLICE PLATE 3/4" DIA. x 8" ROUND HI WITH HEX NUT & WASHER 5/6" DIA. x 6" ROUND HE WITH HEX NUT & WASHER POST CONNECTION FOR STRAIGHT SECTIONS NTS SEAL 1 ISSUED FOR PERMITTING 2015.04.17 REV. NO. DESCRIPTIONS DATE REVISIONS HOLE (TYP.) x 12" x 10' ROUGH WN TIMBER RAIL A. x 4" LAG SCREW 'ILL 3/8" HOLES :) IN TIMBER (TYP.) )OD BLOCKOUT LONG SEAL ,, ��N ... c?Rp ''% 036348 % 04/17/2015 � STRAIGHT SPLICE PLATE 3" 1 1 1/2" \- STANDARD STEEL RAIL �W6x15 STEEL POST -n1 nl -ni=ne 1" MIN. o. A EXPOSED GALVANIZING REAR VIEW POST CONNECTION ELEVATION NTS 6" `O 2 1/2' I 2' 3 1/4" N 4„ 1/2" � 1/2" 1 —4" 1/2 DELINEATOR 1" MIN. EXPOSED GALVANIZING 2' MIN. STANDARD SECTION WITH CURB NTS DELINEATOR SPACING CURVE RADIUS SPACE < 300' 20' > 300' 50' v qKM&CMED v 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233 -8091, Fax: (919)233 -8031 F -1222 www.mckimcreed.com TOP OF SLOPE 13/6 "O HOLES (TYP.) A-� 29_0„ + +� 8— 4» 2' -3„ A-<-J VIEW A APPROACH AND DEPARTURE FLARE WITH FLARED ANCHOR TERMINAL (FAT) NTS z_w o 6" 1' -0" F1'r- GROUND LINE jN i� w 3/4'x1' -9" BOLT WITH HEX NUT AND WASHER r > (TYP.) N Y2" THICK STEEL BEARING PLATES 2' -3„ SECTION A -A CONCRETE ANCHOR NTS NOTES 1. MATERIALS AND CONSTRUCTION OF THE GUARDRAIL SHALL CONFORM TO SPECIAL PROVISION PROVIDED WITH THE PROJECT.ALL HARDWARE IN CONTACT WITH THE GROUND SHALL BE GALVANIZED IN ACCORDANCE WITH THE SPECIAL PROVISION. 2. DELINEATOR REFLECTORS SHALL BE BROWN PLASTIC INVERTED T— SECTIONS CONFORMING TO DURAFLEX CORP. SLEXX 2020, OR APPROVED EQUAL. REFLECTIVE SHEETING SHALL BE SQUARE, AND A MINIMUM OF 19 SQ. IN., AND CONFORM TO SECTION M.18.09. DELINEATORS SHALL BE ATTACHED WITH FOUR (4) 1" — LONG, GALVANIZED WOOD SCREWS. REFLECTORS SHALL BE SPACED IN ACCORDANCE WITH THE TABLE, AND POSITIONED PERPENDICULAR TO THE ADJACENT EDGE OF LANE. DO NOT ATTACH REFLECTORS ON FLAIR OR TERMINAL SECTIONS. REFLECTIVE SHEETING SHALL BE SILVER —WHITE ON ALL RAIL SECTIONS ADJACENT TO THE RIGHT SHOULDER, AND YELLOW ON RAIL SECTIONS ADJACENT TO THE LEFT SHOULDER OF TRAVEL LANES. 3. TWO ADDITIONAL 5/6" DIA. X 4" LONG LAG SCREWS AND WASHERS SHALL BE INSTALLED AT ALL MID —SPAN POINTS FOR STANDARD SYSTEMS. 4. ALL CONNECTION HARDWARE SHALL BE SUFFICIENTLY TIGHTENED TO ACCOMMODATE FOR SHRINKAGE OF THE WOOD ELEMENTS. BRIAR-7SKCHAPEL'� "I L17 Newland COMMUNITIES 9„ 3/6"O HOLE (TYP.) 3" 3" STEEL BEARING PLATE 5. FOR THE END ANCHOR TYPE II, EXTEND THE FLARE INTO THE CUT SLOPE UNTIL A MINIMUM 12" OF COVER IS OBTAINED OVER THE GUARDRAIL END. 6. FOR THE END ANCHOR TYPE I, EXTEND THE FLARE OUT SIDE THE CLEAR ZONE AND BURY THE GUARDRAIL END TO OBTAIN A MINIMUM COVER OF 4 ". 7. BEGIN THE CUT FLARE AT THE NEAREST POST TO A TRANSITION POINT BETWEEN FILL AND CUT AS DIRECTED BY THE ENGINEER. 8. THE GUARDRAIL FLARE SHOWN ON THE MISCELLANEOUS DETAILS IS THE MINIMUM LENGTH AND RATE REQUIRED AS DIRECTED BY THE ENGINEER. FLARE THE GUARDRAIL SO THAT THE TERMINAL SECTION IS OUTSIDE THE CLEAR ZONE. BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA GUARDRAIL DETAILS DATE: APRIL 17, 2015 MCE PRO3. # 02735 -0113 D RAW N BSS DESIGNED BSS CHECKED GCA PRO3. MGR. CHS D2.3 N/A SCALE MBC FILE NUMBER D2.X HORIZONTAL: DRAWING NUMBER N/A VERTICAL: D2.3 N/A STATUS: FINAL DRAWINGS REVISION ,FOR REVIEW PURPOSES ONLY 1 , BIORETENTION AREA #20 PLAN VIEW SCALE = 1 " = 20' 3•• I IN SITU MATERIAL 6 IN. PERFORATED HDPE SECTION NTS SEAL 1 ISSUED FOR PERMITTING 2015.04.17 REV. NO. DESCRIPTIONS DATE REVISIONS SEAL \ ,, , , , \ I I I I I I I I ///,// ...�?,, RO''% 036348 C •, 04/17/2015 ENGINEER.• �Q�•\\. 7r_ FINISH GRADE EL.521.00 - 6" PERFORATED HDPE UNDERDRAIN PIPE '7 1 -YR WSE 522.34' TOP OF RIPRAP EL= 521.50 v v qKM&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233 -8091, Fax: (919)233 -8031 F -1222 www.mckimcreed.com '43 PLACE CEMENT MORTAR CONCRETE PRESSURE PIPE JOINT DETAIL NTS 3' BERM WIDTH BIORETENTION SURFACE AND SIDE TOP EL. 521.50 SLOPES TO BE PLANTED WITH RFRMIInA Rnn GRnWN IN NON- CLAYEY SOILS , _ 3• SOLID 6" PVC -\ FILTER FABRIC LINING 4 IN. WASHED SAND BRIAR-7SKCHAPEL'� Newland COMMUNITIES PLACE CEMENT MORTAR IN JOINT SPACE SECTION H HDPE FLAT ROOF TRASH RACK 24' WIDE x 3" TALL OPENING INV. 522.00 CAP AND COUPLING FLUSH WITH GRADE ....... ........ . . . . . . t BIORETENTION AREA NOTES: 1. ALL CONCRETE TO BE 3000 PSI ® 28 DAYS. 2. ALL STORM DRAIN CLEANOUTS ARE TO BE SPACED AT 75' MAX. 3. CONTRACTOR SHALL CALL ENGINEER FOR ON —SITE INSPECTION OF BIORETENTION AREA DURING CONSTRUCTION. 4. BIORETENTION AREA TO BE PROTECTED FROM SEDIMENT ACCUMULATION DURING ALL PHASES OF CONSTRUCTION. 5. BIORETENTION MEDIA SHALL NOT TO BE PLACED UNTIL 100% OF DRAINAGE AREA TO POND IS STABILIZED WITH HARDSCAPE, TURF, ETC. 6. BIORETENTION MEDIA IS TO BE PLACED AND RAKED IN BY HAND. AT NO TIME SHALL LARGE EQUIPMENT DRIVE OVER THE MEDIA AFTER IT HAS BEEN PLACED. THE MEDIA SHALL NOT BE COMPACTED OVER 85 %. STANDARD PROCTOR IN ORDER TO MAINTAIN PROPER INFILTRATION RATES. 7. MAXIMUM TIME WATER SHOULD POND IS 12 HOURS. 8. IF SOD IS TO BE INSTALLED, ONLY SOD GROWN IN SANDY SOILS ARE TO BE ALLOWED. SOD GROWN IN CLAY SOILS WILL NOT BE ALLOWED. ENGINEERED BIORETENTION AREA MEDIA: in law I =,Wa, 11121 e�"1• 11w*i. I_1 I41111111I21:4mfli =10 4 501112 2 1eZ9l:4rh1NY-5 A)PH RANGE: 5.5 — 6.5 ASTM D4972 B)ORGANIC MATTER: 3 — 5% AASHTO T194 C)SAND CONTENT 85— 88% AASHTO T88 D)FINES (SILT AND CLAY) CONTENT 8 — 12% AASHTO T88 E) PHOSPHOROUS INDEX (P -1) 10 — 30 NCDA 2. BIORETENTION MEDIA SHALL HAVE A MINIMUM INFILTRATION RATE OF 1.0 " /HR. 3. BIORETENTION MEDIA SHALL HAVE A MAXIMUM INFILTRATION RATE OF 6.0 " /HR. 4. THE MEDIA SHALL BE A UNIFORM MIX, FREE OF STONES, STUMPS, ROOTS OR OTHER SIMILAR OBJECTS LARGER THAN TWO INCHES. NO MATERIALS OR SUBSTANCES SHALL BE MIXED OR DUMPED WITHIN THE BIORETENTION AREA THAT MAY BE HARMFUL TO PLANT GROWTH, OR PROVE A HINDRANCE TO THE PLANTING OR MAINTENANCE OPERATIONS. THE PLANTING SOIL SHALL BE FREE OF BERMUDA GRASS, QUACKGRASS, JOHNSON GRASS, OR OTHER NOXIOUS WEEDS. 5. PLANTING MEDIA SHALL BE TESTED PRIOR TO INSTALLATION TO MEET THE CRITERIA LISTED ABOVE AND RESULTS SENT TO CIVIL ENGINEER FOR REVIEW AND APPROVAL. 6. BIORETENTION MEDIA SHALL BE 'BIORETENTION MIX' FROM WADE MOORE EQUIPMENT COMPANY, INC. IN LOUISBURG, NC. (919) 496 -3794. HDPE FLAT ROOF TRASH RACK 24' WIDE x 4" TALL OPENING (2 SIDES W/ HDPE FLAT ROOF TRASH RACK) INV. 522.40 �b TOP ELEV.= 523.50 18" CONCRETE PRESSURE PIPE INV. 517.23 SEE DETAIL SHEET D4.1 III PHIMI /_t12INI11 BIORETENTION AREA SECTION NTS BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA BMP #20 PLAN & DETAILS 24 IN. -5 FT. x5 FT. x1 FT. THICK CAST IN PLACE ANTIFLOTATION BLOCK 4 - #8 BARS (G60) 45 DEG. AROUND BASE THAT PENETRATE THROUGH RISER COMPACTED ABC STONE WRAPPED IN NON -WOVEN FILTER FABRIC r DATE: -144 APRIL 17, 2015 MCE PROS. # 02735 -0113 D RAW N BSS DESIGNED BSS CHECKED GCA PROS. MGR. CHS ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ ❑❑ 3' X 3' PRECAST CONCRETE RISER 6" HDPE INV. IN 517.33 �b TOP ELEV.= 523.50 18" CONCRETE PRESSURE PIPE INV. 517.23 SEE DETAIL SHEET D4.1 III PHIMI /_t12INI11 BIORETENTION AREA SECTION NTS BRIAR CHAPEL BOULDER POINT DRIVE EXTENSION CHATHAM COUNTY, NORTH CAROLINA BMP #20 PLAN & DETAILS 24 IN. -5 FT. x5 FT. x1 FT. THICK CAST IN PLACE ANTIFLOTATION BLOCK 4 - #8 BARS (G60) 45 DEG. AROUND BASE THAT PENETRATE THROUGH RISER COMPACTED ABC STONE WRAPPED IN NON -WOVEN FILTER FABRIC r DATE: -144 APRIL 17, 2015 MCE PROS. # 02735 -0113 D RAW N BSS DESIGNED BSS CHECKED GCA PROS. MGR. CHS SCALE MBC FILE NUMBER D3.X HORIZONTAL: DRAWING NUMBER AS NOTED VERTICAL: D3.1 N/A STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY 1