Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0002648_Monitoring - 02-2023_20230318
Monitoring Report Submittal ..................................................... Permit Number#* WQ0002648 Name of Facility:* Seagrove Ulah Metropolitan Month: * February Year: * 2023 Report Information Type* Upload Document* NDMR, NDAR-1, NDAR-2, NDMLR 2-23 Feb 2023 NDMR,NDAR Signed.pdf 1.87MB PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). Confirmation Email Address: * Itchilton128@gmail.com Name of Submitter: * Larry T. Chilton Signature: �t-tJ ���il�iar Date of submittal: 3/18/2023 This will be filled in automatically Initial Review Reviewer: Wanda.Gerald Is the project number correct?* WQ0002648 Is the monitoring report accepted?* Yes No Regional Office* Winston-Salem Reviewer: _anonymous Review Date: 4/18/2023 FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page + of_� Permit No.: WQ0002648 IFacility Name: Seagrove -Utah Metropolitan ICounty: Randolph Month: February Year: 2023 PPI: 001 Flow Measuring Point: 2 Influent ❑ Effluent ❑ No flow generated Parameter Monitoring Point: [I Influent ❑r Effluent ❑Groundwater Lowering [ISurface Water Parameter Code ---► 60050 00310 00940 50060 31616 00610 00625 00620 00600 00400 00665 70300 00630 WC Q o Un a ` O C WU _� C_ rE� e ` Z � e Z C °E 0 C. oO o II C O_ N �y 900 y 24-hr hrs GPD mg/L m /L mg/L #/100 mL mg/L mg/L mg/L m /L su mg/L mg/L m /L 1 06:30 8 34,400 1.6 7.2 2 06:30 8 65,700 1.5 7.2 3 06:30 8 101,000 1.3 7.1 4 04:00 8 26,900 2.2 6.9 5 03:00 8 16,700 2.1 6.9 6 06:30 8 28,500 1.9 6.7 7 06:30 8 33,200 1.9 7.2 8 06:30 8 27,900 1.8 7.2 9 06:30 8 26,000 1.8 71 10 06:00 8 24,300 2 71 11 04:00 8 44,100 1.3 6.9 12 04:00 8 153,100 0.6 6.6 13 06:00 8 42,100 0.8 6.7 14 06:00 8 28,000 0.9 6.6 15 06:30 8 21,800 1.1 7,2 16 06:30 8 18,100 1.5 7.3 17 06:00 8 31,300 1.6 7.2 18 04:00 8 12,600 1.4 7 19 04:00 8 12,100 2 7.1 20 6100 8 23,300 1.9 7 21 06:30 8 11,200 7.09 1.7 12 29.2 30.8 27.4 60.8 6.9 6.01 9.6 22 06:00 8 28,400 1.5 6.9 23 06:00 8 30,100 1 1.7 1 6.9 24 06:00 8 17,800 1.8 6.8 25 11:00 8 21,700 1 7 26 04:00 8 13,400 0.5 6.8 27 06:30 8 26,400 1 6.7 28 06:00 8 24,200 1.3 7.2 29 30 31 Average: 33,725 7.09 1,49 12.00 29.20 30.80 27.40 60.80 6.01 9.60 Daily Maximum: 153,100 7.09 2.20 12.00 29.20 30.80 27.40 60.80 7.30 6.01 9.60 Daily Minimum: 11,200 7.09 0.50 12.00 29.20 30.80 27.40 60.80 6.60 6.01 9.60 Sampling Type: Recorder Grab Grab Grab Grab Grab Grab Grab Grab Grab Grab Grab Grab Monthly Avg. Limit: 30,000 Daily Limit: Sample Frequency: Continuous Monthly 3 X Year 5 X Week Monthly Monthly Monthly Monthly Monthly 5 X Week Monthly 3 X Year Monthly FORM: NDAR-1 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page oZ of S --- Permit No.: WQ0002648 Facility Name: Seagrove-Ulah Metropolitan Water District WWTP County: Randolph Month: February Did irrigation occur this facility? rA 01 amField©at [a YES ONO •... .. o ■ .. ". o ■ I. �. .. «� .. •. o ■ • ileum ®®®®®®®®® FORM: NDAR-1 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page f of -6- Permit No.: 11111 . -_• . - Metropolitan - District WWTP County:Randolph M.nth: FebruaryDid irrigation occur Field Name: Area (acres): Area (acres). at this facility? �I�� , Cover • I■1�- • . III Crop: ■ . .. , •er . (acres): AnnualEl YES El NO Hourly Rate (in): Hourly Rate (in).i Hourly Rate (in): lrrnlll��� AnnualRa � Field I Mai- ®mm�®' -�® i / • i �� / i i / �{�� i is i 1: -_-_ • n t h I y L ..d i n .ME%�jj�/�jjjj����j��j • •• FORM: NDAR-1 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page q- of -.I- Permit No.: W00002648 Facility Name: Seagrove-Ulah Metropolitan Water District WVVTP County: Randolph Month: February • irrigation occur at this facility? [0 YES ■ NO 111111111M. W.. ��11 1 ...Field Irrigated?:o ■ •Field Irrigated.o ■ • .. o ■ . .. ■ o • 11111m,N111 Mill' m m=M MM--_- ®om®®= M =®= M_-_-- FORM: NDAR-1 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page _, -of -,T- Permit No.: QI01 -... - Metropolitan . Randolphnth: February Year: 2023 ROMM • irrigation occ Area (acres): 9 YES El NO Hourly Rate (in): Hourly Rate (iny Annual Rate (in): 1111111TRITIF1 I M I Annua.1 Rate (iny. Field Irrigatedl? Field Irrigated? sell MMMI'MMMI'mm Monthly Loading: FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page I of � Sampling Person(s) Name: Chris Cameron w/Cameron Testing Services Name: Certified Laboratories Name: Cameron Testing Services Name: Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? u compuant u r4o„-�v... P a- If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taKen. Haacn aaamonai sneers It necessary. monthly average Influent was over the permitted allowance of 30,000 gallons. This is due In part to I&I, the source of which has yet to be determined. Another major factor Is that the Flume where the Influent Meter ,or is located is too small for the flow we see at peak flow. The technitian that installed, calibrated, and certified the meter noted this when he installed the meter. When the flow gets higher than the flume the meter high rather than fail to zero. I have informed the leadership of the Board of Directors that the manhole and flume need total replacement with the proper sized inlet and meter measurement flume so we can have rate flow numbers. When the flow gets above the flume there is no possibility of having accurate flow numbers and as it currently is I beleive the flow numbers at peak flow are exaggerated especially during rain is when we see the W. I am hopeful with the pending plans to make upgrades to this outdated treatment facility that this issue will be adressed. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: 2WW-10681 SI-28234 Permittee. Seagrove/Utah Metropolitan Water District Certification No.: Signing Official: Michael T. Walker Grade: 2 Phone Number: 336-302-3782 Signing Official's Title: Secretary Has the ORC changed since the previous NDMR? ❑ Yes 12 No Phone Number: 336-873-9055 Permit Expiration: 4/30/2027 / 7 4,�:nd�L 3 - S?- g_oR'3 Signature Date 11Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance designed to that gathered and evaluated the information submitted. Based on with a system assure all qualified personnel properly my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations, Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDAR-1 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page A of15-_ Did the application rates exceed the limits in Attachment B of your permit? Were adequate measures taken to prevent effluent ponding in or runoff from the sites? Was a suitable vegetative cover maintained on all sites as specified in your permit? Were all setbacks listed in your permit maintained for every application to each permitted site? Were all freeboards maintained in accordance with the specified freeboard heights in your permit? 10 Compliant ❑ Non -Compliant 10 Compliant ❑ Non -Compliant 17 Compliant ❑ Non -Compliant 0 Compliant ❑ Non -Compliant © Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) k Att h ddifonal sheets if necessary to en. ac a I No irrigation occurred during rain. Rain was evening and overnight after irrigation event. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Larry T. Chilton Permittee: Seagrove/Utah Metropolitan Water District Certification No.: 2WW-10681 SI-28234 II Signing official: Michael T. Walker Grade: 2 Phone Number: 336-302-3782 Signing Official's Title: Secretary Has the ORC changed since the previous NDAR-1? ❑ Yes O No Phone Number: 336-873-9055 Permit Exp.: 4/30/27 7E3-7-2Pa,3 .�. Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for is, to the best of my knowledge and belief, true, accurate, and complete. I am gathering the information, the information submitted aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDAR-1 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page 3 of S Did the application rates exceed the limits in Attachment B of your permit? © Compliant ❑ Non -Compliant Were adequate measures taken to prevent effluent ponding in or runoff from the sites? [a Compliant ❑ Non -Compliant Was a suitable vegetative cover maintained on all sites as specified in your permit? [0 Compliant ❑ Non -Compliant Were all setbacks listed in your permit maintained for every application to each permitted site? RI Compliant ❑ Non -Compliant Were all freeboards maintained in accordance with the specified freeboard heights in your permit? © Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. No irrigation occurred during rain. Rain was evening and overnight after irrigation event. I Operator in Responsible Charge (ORC) Certification II Permittee Certification I ORC: Larry T. Chilton Permittee: Seagrove/Utah Metropolitan Water District Certification No.: 2WW-10681 SI-28234 I Signing official: Michael T. Walker Grade: 2 Phone Number: 336-302-3782 Signing Official's Title: Secretary Has the ORC changed since the previous NDAR-1? ❑ Yes O No Phone Number: 336-873-9055 Permit Exp.: 4/30/27 L 3 - A";k3 // a 4-- Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision In accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the Information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDAR-1 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page `/ of S Did the application rates exceed the limits in Attachment B of your permit? © Compliant ❑ Non -Compliant Were adequate measures taken to prevent effluent ponding in or runoff from the sites? ❑O Compliant ❑ Non -Compliant Was a suitable vegetative cover maintained on all sites as specified in your permit? O Compliant ❑ Non -Compliant Were all setbacks listed in your permit maintained for every application to each permitted site? ED Compliant ❑ Non -Compliant Were all freeboards maintained in accordance with the specified freeboard heights in your permit? © Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach addltionai sheets it necessary. No irrigation occurred during rain. Rain was evening and overnight after irrigation event. IOperator in Responsible Charge (ORC) Certification II Permittee Certification I ORC: Larry T. Chilton Permittee: Seagrove/Utah Metropolitan Water District Certification No.: 2WW-10681 SI-28234 II Signing Official: Michael T. Walker Grade: 2 Phone Number: 336-302-3782 Signing Official's Title: Secretary Has the ORC changed since the previous NDAR-1? ❑ Yes O No Phone Number: 336-873-9055 Permit Exp.: Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. 4/30/27 0 %/_ -,?.: (-1/ Signature Date I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for athering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDAR-1 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page S of s- Did the application rates exceed the limits in Attachment B of your permit? © Compliant ❑ Non -Compliant Were adequate measures taken to prevent effluent ponding in or runoff from the sites? I] Compliant ❑ Non -Compliant Was a suitable vegetative cover maintained on all sites as specified in your permit? O Compliant ❑ Non -Compliant Were all setbacks listed in your permit maintained for every application to each permitted site? 21 Compliant ❑ Non -Compliant Were all freeboards maintained in accordance with the specified freeboard heights in your permit? © Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. No irrigation occurred during rain. Rain was evening and overnight after irrigation event. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Larry T. Chilton Permittee: Seagrove/Utah Metropolitan Water District Certification No.: 2WW-10681 SI-28234 II Signing official: Michael T. Walker Grade: 2 Phone Number: 336-302-3782 Signing Official's Title: Secretary Has the ORC changed since the previous NDARA? ❑ Yes p No Phone Number: 336-873-9055 Permit Exp.: 4/30/27 Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. _lam Signature Date I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for athering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617