Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0031246_More Information (Received)_20230331
PF-Series Submersible Effluent Pumps: 1-Phase, 60-Hz, 4-inch (100-mm) Applications Our PF-Series 4-inch (100-mm) Submersible Effluent Pumps are designed to transport screened effluent (with low TSS counts) from septic tanks or dosing tanks. These pumps are constructed of light- weight, corrosion -resistant stainless steel and engineered plastics, and are field -serviceable and repairable with common tools. They're also CSA- and UL-certified to U.S. and Canadian safety standards for efflu- ent pumps. PF-Series pumps are used in a variety of applications, including pressur- ized drainfields, packed -bed filters, mounds, aerobic units, effluent irri- gation, liquid -only (effluent) sewers, wetlands, lagoons, and more. These pumps are designed to be used with a Biotube® pump vault or after a secondary treatment system. Discharge connection Franklin liquid end — Suction connection Franklin Super Stainless motor Powered by s�® Franklin Electric us v LR80980 LR2053896 Features/Specifications To specify this pump for your installation, require the following: • Minimum 24-hour run -dry capability (liquid end) with no deterioration in pump life or performance" • 1/8-inch (3-mm) bypass orifice to ensure flow recirculation for motor cooling and to prevent air bind • Liquid -end repair kits available for better long-term cost of ownership • TRI-SEALT°" floating impeller design on 10, 20, and 30 gpm (0.6,1.3, and 1.9 Vsec) models; floating stack design on 50 and 75 gpm (3.2 and 4.7 Vsec) models • Franklin Electric Super Stainless motor, rated for continuous use and frequent cycling • Type SCOW 600-V motor cable (model PF751512 uses 14 AWG, SJOOW, 300-V cord) "Not applicable for 5-hp (3.73 kM models Standard Models See specifications chart on page 2 for a list of standard pumps. For a complete list of available pumps, call Orenco. Product Code Diagram PF ❑ 0❑❑-❑-❑ TLK = ClickTightTm compatible Cord length, ft (m):$ Blank = 10 (3) 20 = 20 (6) 30 = 30 (9) 50 = 50 (15) Check valve: Blank = no internal check valve CV = internal check valves Voltage, nameplate: 1 = 115` 2 = 230 Frequency: 1 = single-phase 60 Hz Horsepower (k": 05 = Y2 hp (0.37) 07 = 3/ hp (0.56) 10 = 1 hp (0.75) 15 = 1 h hp (1.11) 20 = 2 hp (1.50) 30 = 3 hp (2.24) 50 = 5 hp (3.73) Nominal flow, gpm (Usec): 10 = 10 (0.6) 20 = 20 (1.3) 30 = 30 (1.9) 50 = 50 (3.2) 75 = 75 (4.7) Pump, PF Series Y2-hp (0.37 kw) only r Available for 10 gpm (0.6 Usec),1/2 hp (0.37 kw) = Note: 20-ft cords are available only for pumps through 1 Y2 hp Second Stage Recirculation Pump: PF500712 Orenco Systems° • 800-348-9843 • +1 541-459-4449 • www.orenco.com NTD-PU-PF-1 Rev. 10 © 01/21 Page 1 of 4 Specifications E G d ?� +�+ O Cn Q y •� NCM 0 :2 U a� y W y03 0 ce an � y ca � E � � � � � � "a � Y c� a Pump Model c = a z > ¢ > o c _ ._ = PH 00511 s 10(0.6) 0.50 (0.37) 1 115 120 12.7 12.7 1 '/4 in. GFP 23.0 (660) 16 (406) 26 (12) 300 PH 00511 CV 9 10(0.6) 0.50 (0.37) 1 115 120 12.7 12.7 1 '/4 in. GFP 23.0 (660) 16 (406) 26 (12) 300 PH 00512 1 10(0.6) 0.50 (0.37) 1 230 240 6.3 6.3 1 '/4 in. GFP 23.0 (660) 16 (406) 26 (12) 300 PH 00712 4, 5, 9 10(0.6) 0.75 (0.56) 1 230 240 8.3 8.3 1 '/4 in. GFP 25.9 (658) 17 (432) 30 (14) 300 PH 01012 5, 8.9 10(0.6) 1.00 (0.75) 1 230 240 9.6 9.6 1 '/4 in. GFP 27.9 (709) 18 (457) 33 (15) 100 PF200511 1 20(1.3) 0.50 (0.37) 1 115 120 12.3 12.5 1 '/4 in. GFP 22.3 (566) 18 (457) 25 (11) 300 PF200512 8 20(1.3) 0.50 (0.37) 1 230 240 6.4 6.5 1 '/4 in. GFP 22.5 (572) 18 (457) 26 (12) 300 PF201012 4,5.1 20(1.3) 1.00 (0.75) 1 230 240 10.5 10.5 1 '/4 in. GFP 28.4 (721) 20 (508) 33 (15) 100 PF201512 4,5 20(1.3) 1.50 (1.11) 1 230 240 12.4 12.6 1 '/4 in. GFP 34.0 (864) 24 (610) 41 (19) 100 PF300511 9 30(1,9) 0.50 (0.37) 1 115 120 11.8 11.8 1 '/4 in. GFP 21.3 (541) 20 (508) 28 (13) 300 PF300512 1 30(1.9) 0.50 (0.37) 1 230 240 6.2 6.2 1 '/4 in. GFP 21.3 (541) 20 (508) 25 (11) 300 PF300712 8 30(1.9) 0.75 (0.56) 1 230 240 8.5 8.5 1 '/4 in. GFP 24.8 (630) 21 (533) 29 (13) 300 PF301012 4,1 30(1.9) 1.00 (0.75) 1 230 240 10.4 10.4 1 '/4 in. GFP 27.0 (686) 22 (559) 32 (15) 100 PF301512 4,5 30(1.9) 1.50 (1.11) 1 230 240 12.6 12.6 1 '/4 in. GFP 32.8 (833) 24 (610) 40 (18) 100 PF302012 5, 6.' 30(1,9) 2.00 (1.49) 1 230 240 11.0 11.0 1 '/4 in. SS 35.5 (902) 26 (660) 44 (20) 100 PF303012 5, 6, 7, 8 30(1.9) 3.00 (2.23) 1 230 240 16.8 16.8 1 '/4 in. SS 44.5 (1130) 33 (838) 54 (24) 100 PF305012 5, 1.7, 8 30(1.9) 5.00 (3.73) 1 230 240 25.6 25.8 1 '/4 in. SS 66.5 (1689) 53 (1346) 82 (37) 100 PF500511 s 50(3.2) 0.50 (0.37) 1 115 120 12.1 12.1 2 in. SS 20.3 (516) 24 (610) 27 (12) 300 PF500512 s 50(3.2) 0.50 (0.37) 1 230 240 6.2 6.2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300 PF500711k 50(3.2) 0.75 (0.56) 1 a a a !.5 2 in. SS 23.7 (602) 25 (635) 31 (14) 300 PF501012 9 50(3.2) 1.00 (0.75) 1 230 240 10.1 10.1 2 in. SS 27.0 (686) 26 (660) 35 (16) 100 PF501512 4 50(3.2) 1.50 (1.11) 1 230 240 12.5 12.6 2 in. SS 32.5 (826) 30 (762) 41 (19) 100 PF503012 4,1.7, 8 50(3.2) 3.00 (2.23) 1 230 240 17.7 17.7 2 in. SS 43.0 (1092) 37 (940) 55 (25) 100 PF505012 5, 6,', 8 50(3.2) 5.00 (3.73) 1 230 240 26.2 26.4 2 in. SS 65.4 (1661) 55 (1397) 64 (29) 100 PF751012 s 75(4.7) 1.00 (0.75) 1 230 240 9.9 10.0 2 in. SS 27.0 (686) 27 (686) 34 (15) 100 PF751512 75(4.7) 1.50 (1.11) 1 230 240 12.1 12.3 2 in. SS 33.4 (848) 30 (762) 44 (20) 100 1 GFP = glass -filled polypropylene; SS = stainless steel. The 1 Y4-in. NPT GFP discharge is 2 718 in. octagonal across flats; the 1 Y4-in. NPT SS discharge is 2 118 in. octagonal across flats, -and the 2-in. NPT SS discharge is 2 718 in. hexagonal across flats. Discharge is female NPT threaded, U.S. nominal size, to accommodate OrencO discharge hose and valve assemblies. Consult your Orenco Distributor about fittings to connect hose and valve assemblies to metric -sized piping. 2 Minimum liquid level is for single pumps when installed in an Orenco Biotube® Pump Vault or Universal Flow Inducer. In other applications, minimum liquid level should be top of pump. Consult Orenco for more information. 3 Weight includes carton and 10-tt (3-m) cord. 4 High-pressure discharge assembly required. 5 Do not use cam -lock option (0) on discharge assembly. 6 Custom discharge assembly required for these pumps. Contact Orenco. 7 Capacitor pack (sold separately or installed in a custom control panel) required for this pump. Contact Orenco. 8 Torque locks are available for all pumps and are supplied with 3-hp and 5-hp pumps. 9 ClickTightrm compatible. NTD-PU-PF-1 Orenco Systems° • 800-348-9843 • +1 541-459-4449 • www.orenco.com Rev. 10 © 01 /21 Page 2 of 4 Materials of Construction Discharge Glass -filled polypropylene or stainless steel Discharge bearing Engineered thermoplastic (PEEK) Diffusers Glass -filled PPO (Noryl GFN3) Impellers Celcon® acetal copolymer on 10-, 20-, and 30-gpm models; 50-gpm impellers are Noryl GFN3 Intake screen Polypropylene Suction connection Stainless steel Drive shaft 7/16-in. hexagonal stainless steel, 300 series Coupling Sintered stainless steel, 300 series Shell Stainless steel, 300 series Motor Franklin motor exterior constructed of stainless steel. Motor filled with deionized water and propylene glycol for constant lubrication. Hermetically sealed motor housing ensures moisture -free windings. All thrust absorbed by Kingsbury -type thrust bearing. Rated for continuous duty. Single- phase motors are equipped with surge arrestors for added security. Single-phase motors through 1.5 hp (1.11 k" have built-in thermal over- load protection, which trips at 203-221° F (95-105' Q. Using a Pump Curve A pump curve helps you determine the best pump for your system. Pump curves show the relationship between flow and pressure (total dynamic head or "TDH"), providing a graphical representation of a pump's optimal performance range. Pumps perform best at their nominal flow rate. These graphs show optimal pump operation ranges with a solid line and show flow rates outside of these ranges with a dashed line. For the most accurate pump specification, use Orenco's PumpSelecf" software. Pump Curves 500 1 400 PF10 Series, 60 Hz, 0.5 -1.0 hp PF20 Series, 60 Hz, 0.5 1.5 h 400I _ 350 PF2015 PF1010 — 350 = e 300 -- C300 250 250 PF1007 = PF2010 � ...... 'a P�1005 a -- 'a 200 cui "f ate+ 200 \\ PF20051 �\ 150 = 150 100 \ 100 \ 50 y' . '` 50 01 0 2 4 6 8 10 12 14 16 18 0 5 10 15 20 25 30 35 Flow in gallons per minute (gpm) Flow in gallons per minute (gpm) 40 Orenco Systems° • 800-348-9843 • +1 541-459-4449 • www.orenco.com NTD-PU-PF-1 Rev. 10 0 01/21 Page 3 of 4 Pump Curves, Cont. 900 800 as 700 C 600 F. 500 a� t 400 E 300 4 200 100 0 0 100 90 80 c 70 0 60 c,s 50 40 cQ � 30 c 20 10� 0 0 ■■■L__ , ■ �MENEM MEMEEME MIMMMMM M M �® MMMME MM\� MMMMM 5 10 15 20 25 30 35 40 45 Flow in gallons per minute (gpm) PF7515 I [F75'O PF75 Series, 60 Hz,1.0 -1.5 hp I I I I I I I I I I I I I I I I I •f''••l. I I I I I I I I I I I I'•i 10 20 30 40 50 60 70 80 90 100 Flow in gallons per minute (gpm) 450 400 as 350 c C 300 PF50; 250 m 200 = 150 PF50. � PF50' 100 50 i I i I i PF50 Series, 60 Hz, 0.5 - 5.0 hp I I I I I 0 0 10 20 30 40 50 60 70 80 90 Flow in gallons per minute (gpm) Operating Point: 24GPM @ 55 TDH NTD-PU-PF-1 Orenco Systems° • 800-348-9843 • +1 541-459-4449 • www.orenco.com Rev. 10 © 01 /21 Page 4 of 4 PF-Series Submersible Effluent Pumps: 1-Phase, 60-Hz, 4-inch (100-mm) Applications Our PF-Series 4-inch (100-mm) Submersible Effluent Pumps are designed to transport screened effluent (with low TSS counts) from septic tanks or dosing tanks. These pumps are constructed of light- weight, corrosion -resistant stainless steel and engineered plastics, and are field -serviceable and repairable with common tools. They're also CSA- and UL-certified to U.S. and Canadian safety standards for efflu- ent pumps. PF-Series pumps are used in a variety of applications, including pressur- ized drainfields, packed -bed filters, mounds, aerobic units, effluent irri- gation, liquid -only (effluent) sewers, wetlands, lagoons, and more. These pumps are designed to be used with a Biotube® pump vault or after a secondary treatment system. Discharge connection Franklin liquid end — Suction connection Franklin Super Stainless motor Powered by s�® Franklin Electric c us v LR80980 LR2053896 Features/Specifications To specify this pump for your installation, require the following: • Minimum 24-hour run -dry capability (liquid end) with no deterioration in pump life or performance" • 1/8-inch (3-mm) bypass orifice to ensure flow recirculation for motor cooling and to prevent air bind • Liquid -end repair kits available for better long-term cost of ownership • TRI-SEALT°" floating impeller design on 10, 20, and 30 gpm (0.6,1.3, and 1.9 Vsec) models; floating stack design on 50 and 75 gpm (3.2 and 4.7 Vsec) models • Franklin Electric Super Stainless motor, rated for continuous use and frequent cycling • Type SCOW 600-V motor cable (model PF751512 uses 14 AWG, SJOOW, 300-V cord) "Not applicable for 5-hp (3.73 kM models Standard Models See specifications chart on page 2 for a list of standard pumps. For a complete list of available pumps, call Orenco. Product Code Diagram PF ❑ 0❑❑-❑-❑ TLK = ClickTightT" compatible Cord length, ft (m):$ Blank = 10 (3) 20 = 20 (6) 30 = 30 (9) 50 = 50 (15) Check valve: Blank = no internal check valve CV = internal check valves Voltage, nameplate: 1 = 115` 2 = 230 Frequency: 1 = single-phase 60 Hz Horsepower (k": 05 = Y2 hp (0.37) 07 = 3/ hp (0.56) 10 = 1 hp (0.75) 15 = 1 h hp (1.11) 20 = 2 hp (1.50) 30 = 3 hp (2.24) 50 = 5 hp (3.73) Nominal flow, gpm (Usec): 10 = 10 (0.6) 20 = 20 (1.3) 30 = 30 (1.9) 50 = 50 (3.2) 75 = 75 (4.7) Pump, PF Series Y2-hp (0.37 kw) only r Available for 10 gpm (0.6 Usec),1/2 hp (0.37 kw) = Note: 20-ft cords are available only for pumps through 1 Y2 hp First Stage Recirculation Pump: PF751512 Orenco Systems° • 800-348-9843 • +1 541-459-4449 • www.orenco.com NTD-PU-PF-1 Rev. 10 © 01/21 Page 1 of 4 Specifications E G d ?� +�+ O Cn Q y •� NCM 0 :2 U a� y W y03 0 ce an � y ca � E � � � � � � "a � Y c� a Pump Model c = a z > ¢ > o c _ ._ = PH 00511 s 10(0.6) 0.50 (0.37) 1 115 120 12.7 12.7 1 '/4 in. GFP 23.0 (660) 16 (406) 26 (12) 300 PH 00511 CV 9 10(0.6) 0.50 (0.37) 1 115 120 12.7 12.7 1 '/4 in. GFP 23.0 (660) 16 (406) 26 (12) 300 PH 00512 1 10(0.6) 0.50 (0.37) 1 230 240 6.3 6.3 1 '/4 in. GFP 23.0 (660) 16 (406) 26 (12) 300 PH 00712 4, 5, 9 10(0.6) 0.75 (0.56) 1 230 240 8.3 8.3 1 '/4 in. GFP 25.9 (658) 17 (432) 30 (14) 300 PH 01012 5, 8.9 10(0.6) 1.00 (0.75) 1 230 240 9.6 9.6 1 '/4 in. GFP 27.9 (709) 18 (457) 33 (15) 100 PF200511 1 20(1.3) 0.50 (0.37) 1 115 120 12.3 12.5 1 '/4 in. GFP 22.3 (566) 18 (457) 25 (11) 300 PF200512 8 20(1.3) 0.50 (0.37) 1 230 240 6.4 6.5 1 '/4 in. GFP 22.5 (572) 18 (457) 26 (12) 300 PF201012 4,5.1 20(1.3) 1.00 (0.75) 1 230 240 10.5 10.5 1 '/4 in. GFP 28.4 (721) 20 (508) 33 (15) 100 PF201512 4,5 20(1.3) 1.50 (1.11) 1 230 240 12.4 12.6 1 '/4 in. GFP 34.0 (864) 24 (610) 41 (19) 100 PF300511 9 30(1,9) 0.50 (0.37) 1 115 120 11.8 11.8 1 '/4 in. GFP 21.3 (541) 20 (508) 28 (13) 300 PF300512 1 30(1.9) 0.50 (0.37) 1 230 240 6.2 6.2 1 '/4 in. GFP 21.3 (541) 20 (508) 25 (11) 300 PF300712 8 30(1.9) 0.75 (0.56) 1 230 240 8.5 8.5 1 '/4 in. GFP 24.8 (630) 21 (533) 29 (13) 300 PF301012 4,1 30(1.9) 1.00 (0.75) 1 230 240 10.4 10.4 1 '/4 in. GFP 27.0 (686) 22 (559) 32 (15) 100 PF301512 4,5 30(1.9) 1.50 (1.11) 1 230 240 12.6 12.6 1 '/4 in. GFP 32.8 (833) 24 (610) 40 (18) 100 PF302012 5, 6.' 30(1,9) 2.00 (1.49) 1 230 240 11.0 11.0 1 '/4 in. SS 35.5 (902) 26 (660) 44 (20) 100 PF303012 5, 6, 7, 8 30(1.9) 3.00 (2.23) 1 230 240 16.8 16.8 1 '/4 in. SS 44.5 (1130) 33 (838) 54 (24) 100 PF305012 5, 1.7, 8 30(1.9) 5.00 (3.73) 1 230 240 25.6 25.8 1 '/4 in. SS 66.5 (1689) 53 (1346) 82 (37) 100 PF500511 s 50(3.2) 0.50 (0.37) 1 115 120 12.1 12.1 2 in. SS 20.3 (516) 24 (610) 27 (12) 300 PF500512 s 50(3.2) 0.50 (0.37) 1 230 240 6.2 6.2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300 PF500712 9 50(3.2) 0.75 (0.56) 1 230 240 8.5 8.5 2 in. SS 23.7 (602) 25 (635) 31 (14) 300 PF501012 9 50(3.2) 1.00 (0.75) 1 230 240 10.1 10.1 2 in. SS 27.0 (686) 26 (660) 35 (16) 100 PF501512 4 50(3.2) 1.50 (1.11) 1 230 240 12.5 12.6 2 in. SS 32.5 (826) 30 (762) 41 (19) 100 PF503012 4,1.7, 8 50(3.2) 3.00 (2.23) 1 230 240 17.7 17.7 2 in. SS 43.0 (1092) 37 (940) 55 (25) 100 PF505012 5, 6,', 8 50(3.2) 5.00 (3.73) 1 230 240 26.2 26.4 2 in. SS 65.4 (1661) 55 (139� 64 (29) 100 PF751012 s 75(4.7) 1.00 (0.75) 1 230 240 9.9 10.0 2 in. SS 27.0 (686) 27 (686) 34 (15) 100 - E4.7) 1.50 (1.11) @ a a W W j in. SS 33.4 M 30 (762) 1 GFP = glass -filled polypropylene; SS = stainless steel. The 1 Y4-in. NPT GFP discharge is 2 718 in. octagonal across flats; the 1 Y4-in. NPT SS discharge is 2 118 in. octagonal across flats, -and the 2-in. NPT SS discharge is 2 718 in. hexagonal across flats. Discharge is female NPT threaded, U.S. nominal size, to accommodate OrencO discharge hose and valve assemblies. Consult your Orenco Distributor about fittings to connect hose and valve assemblies to metric -sized piping. 2 Minimum liquid level is for single pumps when installed in an Orenco Biotube® Pump Vault or Universal Flow Inducer. In other applications, minimum liquid level should be top of pump. Consult Orenco for more information. 3 Weight includes carton and 10-tt (3-m) cord. 4 High-pressure discharge assembly required. 5 Do not use cam -lock option (0) on discharge assembly. 6 Custom discharge assembly required for these pumps. Contact Orenco. 7 Capacitor pack (sold separately or installed in a custom control panel) required for this pump. Contact Orenco. 8 Torque locks are available for all pumps and are supplied with 3-hp and 5-hp pumps. 9 ClickTightrm compatible. NTD-PU-PF-1 Orenco Systems° • 800-348-9843 • +1 541-459-4449 • www.orenco.com Rev. 10 © 01 /21 Page 2 of 4 Materials of Construction Discharge Glass -filled polypropylene or stainless steel Discharge bearing Engineered thermoplastic (PEEK) Diffusers Glass -filled PPO (Noryl GFN3) Impellers Celcon® acetal copolymer on 10-, 20-, and 30-gpm models; 50-gpm impellers are Noryl GFN3 Intake screen Polypropylene Suction connection Stainless steel Drive shaft 7/16-in. hexagonal stainless steel, 300 series Coupling Sintered stainless steel, 300 series Shell Stainless steel, 300 series Motor Franklin motor exterior constructed of stainless steel. Motor filled with deionized water and propylene glycol for constant lubrication. Hermetically sealed motor housing ensures moisture -free windings. All thrust absorbed by Kingsbury -type thrust bearing. Rated for continuous duty. Single- phase motors are equipped with surge arrestors for added security. Single-phase motors through 1.5 hp (1.11 k" have built-in thermal over- load protection, which trips at 203-221° F (95-105' Q. Using a Pump Curve A pump curve helps you determine the best pump for your system. Pump curves show the relationship between flow and pressure (total dynamic head or "TDH"), providing a graphical representation of a pump's optimal performance range. Pumps perform best at their nominal flow rate. These graphs show optimal pump operation ranges with a solid line and show flow rates outside of these ranges with a dashed line. For the most accurate pump specification, use Orenco's PumpSelecf" software. Pump Curves 500 1 400 PF10 Series, 60 Hz, 0.5 -1.0 hp PF20 Series, 60 Hz, 0.5 1.5 h 400I _ 350 PF2015 PF1010 — 350 = e 300 -- C300 250 250 PF1007 = PF2010 � ...... 'a P�1005 a -- 'a 200 cui "f ate+ 200 \\ PF20051 �\ 150 = 150 100 \ 100 \ 50 y' . '` 50 01 0 2 4 6 8 10 12 14 16 18 0 5 10 15 20 25 30 35 Flow in gallons per minute (gpm) Flow in gallons per minute (gpm) 40 Orenco Systems° • 800-348-9843 • +1 541-459-4449 • www.orenco.com NTD-PU-PF-1 Rev. 10 0 01/21 Page 3 of 4 Pump Curves, Cont. 900 800 as 700 C 600 F. 500 a� t 400 E 300 4 200 100 0 0 100 90 as 80 c 70 0 60 c,s 50 40 c� �. � 30 c 20 10 0 0 ■■■L__ ■ �MENEM MEMEEME MIMMMMM M �® MMMME MM MMMMM 5 10 15 20 25 30 35 40 45 Flow in gallons per minute (gpm) 10 20 30 40 50 60 70 80 90 100 Flow in gallons per minute (gpm) 450 400 as 350 c C 300 250 m 200 = 150 100 50 0 0 PF5050 PF50 Series, 60 Hz, 0.5 - 5.0 hp PF5030 PF5015 \ PF5010 PF5007 ' PF5005 10 20 30 40 50 60 70 80 90 Flow in gallons per minute (gpm) Operating Point: 96GPM @ 47 TDH NTD-PU-PF-1 Orenco Systems° • 800-348-9843 • +1 541-459-4449 • www.orenco.com Rev. 10 © 01 /21 Page 4 of 4