Loading...
HomeMy WebLinkAboutSW1220701_Supplement-EZ Form_20230329SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name All About Plumbing Building Addition 2 Project Area (ac) 3.15 3 Coastal Wetland Area (ac) _ 0 0 4 Surface Water Area (ac) 5 1 Is this project High or Low Density? Low 6 Does this project use an off -site SCM? No COMPLIANCE WITH 02H .1003(4) - 7 Width of vegetated setbacks provided (feet) 30 8 Will the vegetated setback remain vegetated? No 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003(4)(c-d ? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 0 12 Bioretention Cell 0 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting (RWH) 0 18 Green Roof 0 19 Level Spreader -Filter Strip LS-FS) 0 20 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 Ba filter 0 26 1 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: J. David McCutchen, P.E. 28 Organization: McCutchen Engineering Associates, PC 29 Street address: 898 West Saint John Street 30 City, State, Zip: Spartanburg, SC 29301 31 Phone number(s): 864-582-0585 32 Email: dmccutchen@mcc-ea.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. \\O\\\pP� FES...... 2Q SEAL r i 025335 r %INE�P: 41CCV��:?�� Seal 4 5;, T10"s M, 1/6 d§r of dZ�Ixr 5 Date DRAINAGE AREAS 1 Is this a high density project? No 2 If so, number of drainage areas/SCMs 0 3 Does this project have low density areas? Yes 4 If so, number of low density drainage areas 1 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED jDRAINAGE AREA INFORMATION 4 Type of SCM Entire Site LD 1� - 5 Total drainage area (sq ft 137,214 6 Onsite drainage area sq ft) 137,214 7 Offsite drainage area (sq ft 0 8 Total BUA in project (sq ft) 57935 sf 9 New BUA on subdivided lots (subject to permitting) (sq ft N/A 10permitting) New BUA not on subdivided lots (subject to s 14376 sf 11 Offsite BUA (sq ft N/A 12 Breakdown of new BUA not on subdivided lots: Parking (sq ft 7841 sf Sidewalk (sq ft N/A Roof (sq ft 6535 sf Roadway (sq ft) N/A Future (sq ft N/A - Other, please specify in the comment box below (sq ft N/A 13 New infiltrating permeable pavement on subdivided lots (sq ft N/A 14 New infiltrating permeable pavement not on subdivided lots (sq ft N/A 15permitting) Existing BUA that will remain (not subject to sq ft 43560 sf 16 Existing BUA that is already permitted (sq ft sf i 17 Existing BUA that will be removed (sq ft N/A 18 Percent BUA 15% 19 Design storm inches 7.1 in 20 Design volume of SCM (cu ft) f 21 Calculation method for design volume ADDITIONAL INFORMATION 22 Please use this space to provide any additional information about the drainage area(s): LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H .1003 Is project below density thresholds set forth in the applicable stormwater rule? Does project maximize dispersed flow and minimize channelizatlon of flow? Has the use of piping been minimized per. 1 003(2)(c)? Side slopes of the vegetated conveyances (H:V) Yes Yes Yes 3 sf 1 2 3 4 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 2.97 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s) (%) N/A 8 Bottom width of curb outlet swale(s) (feet) N/A 9 Maximum side slope of curb outlet swale(s) (H:V) N/A 10 Minimum length of curb outlet swale(s) (feet) N/A 11 Are treatment swales used instead of curb outlet swales? No 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 I Are variations to rule .1003 proposed? ADDITIONAL INFORMATION 15 1 Please use this space to provide any additional information about this low density project: J No Vegetated grass swales were designed using mannin s equation. See drainage swale calculations in Appendix D of the SWPPP. Swale # Drainage Area BUA (ac) Pervious aarea c Q (cfs) Slope N V,11,w (fps) V,«,,A (fps) Flow depth (ft) 1 0.82 0.57 0.25 0.77 4.50 5.00 4.00 2.97 0.45 2 0.27 0.15 0.12 0.68 1.30 2.00 4.00 1.38 0.32 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30