Loading...
HomeMy WebLinkAboutSW6221101_Supplement-EZ Form_20230327SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 JProject Name 2 Project Area ac 3 Coastal Wetland Area ac 4 Surface Water Area ac 5 Is this project High or Low Density? 6 1 Does this project use an off -site SCM? Fort Braqq Technical Su 15.16 0 0 High No Annex, PN79439.2 COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided feet 30 8 Will the vegetated setback remain vegetated? N/A 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003 4 c-d ? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 12 Bioretention Cell 4 13 Wet Pond 14 1 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting RWH 18 Green Roof 19 Level Spreader -Filter Strip (LS-FS) 20 Disconnected Impervious Surface DIS 21 Treatment Swale 22 Dry Pond 23 StormFilter Silva Cell Bayfilter Filterra 24 25 26 FORMS LOADED IDESIGNER CERTIFICATION 27 Name and Title: 28 Organization: 29 Street address: 30 City, State, Zip: 31 Phone numbers : 32 Email: Lorraine Roberts, PE - Civil Engineer Exp Federal, Inc. 205 N Michigan Ave., Suite 3800 Chicago, IL 60601 312-616-3309 I Lorraine. Robertsna exDfederal.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. ; \A CAROB' oFEss /o i SEAL 046 49 ENGIN R NE B. RO Seal .VJ Signature of Designer 3/22/23 Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 5 3 Does this project have low density areas? No 4 If so, number of low density drainage areas 0 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Type of SCM Entire Site 1 2 3 4 5 4 Bioretention A Bioretention B5 Bioretention B4 Bioretention B3 Bypass 5 Total drainage area (sq ft 722517 421487 57336 36539 50100 157055 6 Onsite drainage area (sq ft 660203 364781 51728 36539 50100 157055 7 Offsite drainage area (sq ft) Total BUA in project s ft New BUA on subdivided lots (subject to s ft) New BUA not on subdivided lots (subject to sf Offsite BUA (sq ft Breakdown of new BUA not on subdivided lots: - Parking (sq ft - Sidewalk (sq ft - Roof (sq ft 2314 56706 5608 0 0 0 8 sf 237759 sf 31155 sf 24840 sf 35607 sf sf 9permitting) [!329361 sf sf sf 31155 sf sf sf 24840 sf sf sf sf 10permitting) 329361 sf sf 237759 sf 35607 sf sf 11 sf sf sf 12 116629 sf 25027 sf 31155 sf 24840 sf 35607 sf sf 1733 sf 1733 sf sf sf sf sf 25222 sf 25222 sf sf sf sf sf - Roadway s ft 31897 sf 31897 sf sf sf sf sf - Future (sq ft sf sf sf sf sf sf - Other, please specify in the comment box below (sq ft 153878 sf sf sf 153878 sf sf sf sf sf sf sf 13 New infiltrating permeable pavement on subdivided lots (sq ft sf sf sf sf 14 New infiltrating permeable pavement not on subdivided lots s ft) Existing BUA that will remain (not subject to permitting)s ft sf sf sf sf 15 sf sf sf sf sf sf 16 ExistingBUA that is alreadypermitted s ft sf sf sf sf sf sf 17 ExistingBUA that will be removed s ft 152178 sf 90848 sf 23311 sf 14434 sf 4957 sf 18628 sf 18 Percent BUA 50% 56% 71 % 68% 71 % 0% 19 Design storm inches 1.0 in 1.0 in 1.0 in 1.0 in 20 Design volume of SCM cu ft 21 lCalculation method for design volume ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): 19588 cf 2576 cf 2015 cf 2879 cf SIMPLE SIMPLE SIMPLE SIMPLE "Other" BUA for DA1 is the paved area around the building. Certain areas of the site bypass the pond, therefore the total site areas will not equal the sum of the pond areas. BIORETENTION CELL 1 Drainage area number 2 Minimum required treatment volume 11cu ft ENERAL MDC FROM 02H .1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? 4 Is the SCM located away from contaminated soils? 5 What are the side slopes of the SCM (H:V)? 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? 7 Are the inlets, outlets, and receiving stream protected from erosion (10-year storm)? 8 Is there an overflow or bypass for inflow volume in excess of the design volume? 9 What is the method for dewatering the SCM for maintenance? 10 If applicable, will the SCM be cleaned out after construction? 11 Does the maintenance access comply with General MDC (8)? 12 Does the drainage easement comply with General MDC (9)? 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? 1 (A) 1 2 (135) 1 3 (134) 1 4 (133) Yes Yes Yes Yes Yes Yes Yes Yes 3:1 3:1 3:1 3:1 No No No No Yes Yes Yes Yes Yes Pump (preferred) Yes Yes N/A N/A Yes Pump (preferred) Yes Yes N/A N/A Yes Pump (preferred) Yes Yes N/A N/A Yes Pump (preferred) Yes Yes N/A N/A 14 Is there an O&M Agreement that complies with General MDC (11)? No No No No 15 Is there an O&M Plan that complies with General MDC (12)? No Yes No Yes No Yes No Yes 16 Does the SCM follow the device specific MDC? 17 Was the SCM designed by an NC licensed professional? Yes Yes Yes Yes 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 SHWT elevation (fmsl) Bottom of the bioretention cell (fmsl) Ponding depth of the design storm (inches) Surface area of the bioretention cell (square feet) Design volume of SCM (cu ft) Is the bioretention cell used for peak attenuation? Depth of peak attenuation over planting surface (in) Height of peak attenuation outlet above the planting surface (in) Infiltration rate of the in situ soil (inch/hour) Diameter of the underdrain pipes (if applicable) Does the design include Internal Water Storage (IWS)? if so, elevation of the top of the IWS (fmsl) Elevation of the planting surface (fmsl) What type of vegetation will be planted? (grass, trees/shrubs, other)? Media depth (inches) Percentage of medium to coarse washed sand by volume Percentage of fines (silt and clay) by volume Percentage of organic matter by volume Type of organic material Phosphorus Index (P-Index) of media (unitless) Will compaction be avoided during construction? Will cell be maintained to a one inch/hour standard? Depth of mulch, if applicable (inches) Type of mulch, if applicable How many clean out pipes are being installed? Tvae of aretreatment that will be used: ADDITIONAL INFORMATION Please use this space to provide any additional information about 44 Ithe bioretention cell(s): Surface area is considered to be the area of the bottom of the pond. Volume accounts for 3:1 sideslopes. Items 12, 14, & 15 are not necessary at Fort Bragg. Fort Bragg has a standard O&M program for the entire base. assumed >250 255.00 12 in 21300 sf 22556 cf Yes 24 in 18 in in/hr 6 in Yes 253.5 255 Grass 30 in 85% 10% 5% Pine Bark Fines 10 Yes Yes N/A N/A y >247 266.00 12 in 3783 sf 4704 cf No N/A N/A in/hr 4 in Yes 264.5 266 Grass 30 in 85% 10% 5% Pine Bark Fines 10 Yes Yes N/A N/A >246 266.00 12 in 4656 sf 5586 cf No N/A N/A in/hr 4 in Yes 264.5 266 Grass 30 in 85% 10% 5% Pine Bark Fines 10 Yes Yes N/A N/A >245 266.00 12 in 4656 sf 5586 cf No N/A N/A in/hr 4 in Yes 264.5 266 Grass 30 in 85% 10% 5% Pine Bark Fines 10 Yes Yes N/A N/A Bioretention 3 2:02 PM 3/22/2023