Loading...
HomeMy WebLinkAboutNC0021733_Authorization to Construct_20030812State of North Carolina Department of Environment and Natural Resources ®i • 0, Asheville Regional Office — — Michael F. Easley, Governor NCDENR William G. Ross, Jr., Secretary Alan W. Klimek P.E. Director f f NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Coleen H. Sullins, Deputy Director Division of Water Quality WATER QUALITY SECTION August 12, 2003 Mr. John Dodson, Mayor Town of Marshall PO Box 548 Marshall, North Carolina 28753 Mr. Brian Tripp, P.E. Hobbs, Upchurch and Associates, P.A. 1300 Baxter Street; Suite 108 Charlotte. North Carolina 28204 Subject: Authorization to Construct ATC Number 021733A01 Town of Marshall Wastewater Treatment Plant UV Disinfection System NPDES Permit No. NCO021733 Madison County Dear Sirs: A letter of request for an Authorization to Construct was received August 1, 2003 by the Division. Final plans and specifications for the subject project have been reviewed and found to be satisfactory contingent upon the conditions and terms stated in this document. The Town of Marshall is still constrained by the terms and conditions of the current NPDES permit number NC0021733. This Authorization to Construct (ATC) is hereby granted for the construction, installation and modification of a new ultraviolet disinfection system and all necessary appurtenances complete with UV modules, power distribution data center, UV detection system, module -cleaning system, automatic level controls and eye shields consisting of the following: A 1 4 Mr. John Dodson Mr. Brian Tripp August 12, 2003 page 2 of 3 {1 } two (2) vertical UV disinfection modules (designed to provide adequate disinfection at peak hourly flow with one bank out of service {2} power distribution center, control panel and interconnecting cables to modules {3} UV intensity monitoring system(s) . {4} UV eye shields {5} module cleaning station liner {6} automatic energy conservation flow pacing system {7} static effluent level control device {8} module lifting beam hoist (120 volt, 1 phase, 60 Hz) {9} in -channel cleaning system {10} waterproof stainless steel door for entry into the UV vault {11 } blower for the air scrubber system {12} foundations, concrete channels, conduits, handrails and stairs {13} main electrical power source {14} control wiring and installation for remote signals {15} piping, channel drains and valves {16} walkway grating {17} channel isolation gates (as necessary) In addition, reliability requirements for UV disinfection systems consist of the following: {1 } standby power (per 15 NCAC 2H .0100 Rules, Procedures for Implementation) {2} ability to notify the ORC (operator in responsible charge) of lamp / unit failures (use an autodialer, since the ORC is not present at all times, and audible and visible alarms) {3} automatic controls to alternate to backup units in case of failure The Division of Water Quality's Asheville Regional Office, telephone number 828-251- 6208, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an in -place inspection can be made. Such notification to the DWQ Regional Supervisor or DWQ county contact shall be made during normal office hours from 8:00 am until 5:00 pm on Monday through Friday, excluding State Holidays. Upon completion of construction, installation and modification and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with this Authorization to Construct and the approved plans and specifications. Mail the Certification to the NCDENR- DWQ, NPDES Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division of Water Quality in accord- ance with North Carolina General Statutes 143-215.6A to 143-215.6C. Mr. John Dodson Mr. Brian Tripp August 12, 2003 page 3 of 3 The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations or ordinances which may be imposed by other government agencies (local, state and federal) which have jurisdiction. One (1) set of approved plans and specifications is being forwarded to you. If you have any questions or need additional information, please contact Wanda Frazier, telephone number 828-251-6208, extension 218. Sincerely, Forrest R. Westall Water Quality Regional Supervisor cc: Central Files (no enclosures) Madison County Health Department (no enclosures) NPDES Unit (ATC file - no enclosures) Mike Ladd, Earth Environmental Services (no enclosures) ATC PROCESSING Facility: PUBLIC INFO, ASSIST, NPDES CHECK LIST ATC No SCOPE of Project: Di<-j �7► Pull existing permit, (is this action allowed?): .� • Will this activity require a change notice to compliance? YES NO VPoint Assignment: (O SUBMITTAL: V Letter of Request from the Permittee !�'(3) Plans, Specifications and Design Calculations * signed & sealed by NC PE ? three sets of each? ACTION: rejection (reason): hold for: accept (date): ' LOG IN & DISPERSAL (Once package is complete): Log on BIMS / determine the ATC number/ create and print out tracking slip /Log on the Units' ATC data base Create and send acknowledge letter (date sent): .0-2 ^a? * to permittee/consultant/NPDES file Al V-141 &I I W-i 6V Request Staff Report from Regional Office sent on: X-- (assemble the following and mail by courier to- the appropriate RO): * copy of the acknowledgment letter (highlight RO), * copy of the request letter, * copy of submittal package (plans, specs and calculations), ASSIGNED: --�Zreviewer:w6u, l f :- ZJ6k— date: A-1 I-), APPROVED North Carolina Environmental Management Commission Division of Water Quality A TC process 8127198 0. RO r��t# Are--