Loading...
HomeMy WebLinkAboutNCC230476_Site Plan or Location Map_20230329CUI//FEDCON - PROPRIETARY AND CONFIDENTIAL - DO NOT DUPLICATE OR REDISTRIBUTE WITHOUT THE EXPLICIT CONSENT OF ASUS i COD ' U / REILLY RD. ® 30k0 �Zg�.pO C-02 z$k0° / C-03 23-rOp 2 26+Op ZZkOp 4xp0 00 2�-rOp ZOk00 �gk00 �N 0 / BOOSTER ST. A EL EL 0 N 0 N V W w 0 J d ::�- - 3 %gk00 \N C-04 C-05 /zc b'b'r00 45+00 46+ 00 iiiiiiiiiiiiiiiiiiiiiillillill 8x00 9x00 s0 x°o \ S �x Oo !/2x°O C-06 \ s-x 00 sQ x°o \ SS^°O C-07 /l / AY- x° o , ate® ^�o C-09 0 /fox° o 0 As r IV ��'`/ 0 isT�go 0 ��x° ST x sT 40 GRAPHIC SCALE 200 0 100 200 400 ( IN FEET ) 1 inch = 200 ft. NOTES 1. ASUS MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN INCLUDE ALL UNDERGROUND UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. ASUS FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. ASUS DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM AVAILABLE INFORMATION. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING DEPTH AND LOCATION OF ALL UTILITIES PRIOR TO CONSTRUCTION. 2. THIS DRAWING IS BASED ON SURVEY INFORMATION AND DESIGN DRAWINGS PROVIDED BY THE GOVERNMENT AND IS NOT THE RESULT OF A FIELD SURVEY BY ASUS OR SHIPMAN ENGINEERING, PLLC. NO ACTUAL FIELD VERIFICATION WAS PERFORMED, EXCEPT IN THE AREAS INDICATED ON THE DRAWINGS. EXISTING CONDITIONS SHOWN SHOULD BE CONSIDERED APPROXIMATE IN NATURE AND FIELD VERIFIED PRIOR TO CONSTRUCTION. 3. CONTRACTOR TO SCHEDULE SHUTDOWN OF EXISTING WATER LINES AND SEWER LINES WITH ASUS PERSONNEL PRIOR TO CONNECTION TO ALL EXISTING WATER LINES AND SEWER LINES. 4. EXISTING UNDERGROUND WATER LINES AND FORCE MAINS ARE ASSUMED TO BE 3-FEET BELOW GRADE TO TOP OF PIPE. CONTRACTOR IS RESPONSIBLE FOR VERIFYING LOCATION AND DEPTH PRIOR TO EXCAVATION OR CONNECTION. 5. EXISTING GRAVITY MAINS ARE ASSUMED TO BE AT THE DEPTHS SHOWN ON THE PLANS. CONTRACTOR IS RESPONSIBLE FOR VERIFYING LOCATION AND DEPTH PRIOR TO EXCAVATION OR CONNECTION. 6. EXISTING UNDERGROUND UTILITIES BY OTHERS ARE ASSUMED TO BE 3-FEET BELOW GRADE TO TOP OF THE UTILITY LINE. DIAMETER OF UTILITY LINE, UNLESS NOTED, IS UNKNOWN. CONTRACTOR IS RESPONSIBLE FOR VERIFYING LOCATION AND DEPTH OF ALL UTILITIES PRIOR TO STARTING CONSTRUCTION. LOCATION OF SANITARY SEWERS IN RELATION TO WATER AND STORM SEWERS: A. SEWERS SHALL BE LAID AT LEAST 10 FEET HORIZONTALLY FROM ANY EXISTING OR PROPOSED WATER MAIN. THE DISTANCE SHALL BE MEASURED EDGE TO EDGE. IN CASES WHERE IT IS NOT PRACTICAL TO MAINTAIN A 10 FOOT SEPARATION, THE APPROPRIATE REVIEWING AGENCY (DEH OR DENR) MAY ALLOW DEVIATION ON A CASE BY CASE BASIS, IF SUPPORTED BY DATA FROM THE DESIGN ENGINEER. SUCH DEVIATION MAY ALLOW INSTALLATION OF THE SEWER CLOSER TO A WATER MAIN, PROVIDED THAT THE WATER MAIN IS IN A SEPERATE TRENCH OR ON AN UNDISTURBED EARTH SHELF LOCATED ON ONE SIDE OF THE SEWER AND AT AN ELEVATION SO THAT THE BOTTOM OF THE WATER MAIN IS AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER. B. IF IT IS IMPOSSIBLE TO OBTAIN PROPER HORIZONTAL AND VERTICAL SEPARATION AS DESCRIBED ABOVE OR ANYTIME THE SEWER IS OVER THE WATER MAIN, BOTH WATER MAIN AND SEWER MUST BE CONSTRUCTED OF FERROUS PIPE COMPLYING WITH PUBLIC WATER SUPPLY DESIGN STANDARDS AND BE PRESSURE TESTED TO 200 PSI TO ASSURE WATERTIGHTNESS BEFORE BACKFILLING. C. A 24 INCH VERTICAL SEPARATION SHALL BE PROVIDED BETWEEN STORM SEWER AND SANITARY SEWER LINES OR FERROUS PIPE SPECIFIED. CROSSINGS: A. SEWERS CROSSING WATER MAINS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 18 INCHES BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF THE SEWER. THE CROSSING SHALL BE ARRANGED SO THAT THE SEWER JOINTS WILL BE EQUIDISTANT AND AS FAR AS POSSIBLE FROM THE WATER MAIN JOINTS. B. WHEN IT IS IMPOSSIBLE TO OBTAIN PROPER HORIZONTAL AND VERTICAL SEPARATION AS STIPULATED ABOVE, ONE OF THE FOLLOWING METHODS MUST BE SPECIFIED I. THE SEWER SHALL BE DESIGNED AND CONSTRUCTED OF FERROUS PIPE AND SHALL BE PRESSURE TESTED AT 200 PSI TO ASSURE WATERTIGHTNESS PRIOR TO BACKFILLING, OR II. EITHER THE WATER MAIN OR THE SEWER LINE MAY BE ENCASED IN A WATERTIGHT CARRIER PIPE WHICH EXTENDS 10 FEET ON BOTH SIDES OF THE CROSSING, MEASURED PERPENDICULAR TO THE WATER MAIN. THE CARRIER PIPE SHALL BE OF MATERIALS APPROVED BY THE REEGULATORY AGENCY OF USE IN WATER MAIN CONSTRUCTION. WARNING: CONTRACTOR SHALL NOTE THAT ALL OF THE EXISTING UTILITIES MIGHT NOT BE SHOWN HEREON AND THAT ANY EXISTING UTILITIES THAT ARE SHOWN ARE IN APPROXIMATE LOCATION HORIZONTALLY AND VERTICALLY. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO CONDUCT ALL 800 NECESSARY FIELD INVESTIGATIONS PRIOR TO ANY EXCAVATION TO DETERMINE THE ACTUAL LOCATION HORIZONTALLY AS WELL AS VERTICALLY OF ALL UTILITIES. CALL BEFORE YOU DIG (SEE SHT. N-01) o , m w 0 U w 0 U 0 w K 0 w K 0 w z a 0 w z a H z z Q H z z Q SHIPMAN ENGINEERING NCBELS LICENSE P-1963 137 MIDDLEGREEN PL. HOLLY SPRINGS, NC 27540 (919) 900-0006 �1 V) L OlN 0 cn(A o ra m m +j N__ L O 01 � m o z 6 8 ai LL C 0 � Z L Z 20 M m 00Jm V n� 0 CDouCNw • (6 N U • '� � • L EL ��• i •> z_ Q w � z w Q U Lu 2 w � (-)0 06 z a Q N z a_ � Lu Q w w w � Q Q a Q >- w Q w w > w 0 0 w Project No.: ON-0009-20 GWO No.: 252000587 Date: NOVEMBER 11, 2020 Drawn: WZS Designed: WZS Reviewed: WZS Approved: ---- Scale: AS NOTED Sheet: C 00