Loading...
HomeMy WebLinkAboutSW8970834_Historical File_19980126State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office James B. Hunt, Jr., Governor Wayne McDevitt, Secretary Division of Water Quality January 26, 1998 Mr. James M. Davis, Jr., Chief Operating Officer Pirates Cove LLC 601 Pelletier Loop Road Swansboro, NC 28584 IT A NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: Permit No. SW8 970834 Pirates Cove Townhomes High Density Commercial Stormwater Project Dear Mr. Davis: Onslow County The Wilmington Regional Office received the Stormwater Management Permit Application for Pirates Cove Townhomes on August 15, 1997, with final information on January 16, 1998. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000. We are forwarding Permit No. SW8 970834 dated January 26, 1998, for the construction of Pirates Cove Townhomes. This permit shall be effective from the date of issuance until January 26, 2008, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Linda Lewis, or me at (910) 395-3900. Sincerely, l , L (.�f -- '-') t"--t i' v r �-- t— Rick Shiver, P.G. Acting Regional Water Quality Supervisor RSS/arl: S:\WQS\STORMWAT\PERMIT\970834.JAN cc: John McLean, P.E. Sharon Smith Jennings, Onslow County Inspections Linda Lewis vv 11 ningtori Rcgiunai Office Central Files 127 North Cardinal Dr., Wilmington, North Carolina 28405 Telephone 910-395-3900 FAX 910-350-2004 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper State Stormwater Management Systems Permit No. SW8 970834 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANA EMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Pirates Cove LLC Pirates Cove Townhomes Onslow County FOR THE construction, operation and maintenance of a detention pond in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules ") and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until January 26, 2008 and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described on page 3 of this permit, the Project Data Sheet. The stormwater control has been designed to handle the runoff from 251,949 square feet of impervious area. 3. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit_ 4. The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans. 2 State Stormwater Management Systems Permit No SW8 970834 DIVISION OF WATER QUALITY PROJECT DATA SHEET Project Name: Pirates Cove Townhomes Permit Number: 970834 Location: Onslow County Applicant: Mr. James M. Davis, Jr., Chief Operating Officer Mailing Address: Pirates Cove LLC 501 Pelletier Loop Road Swansboro, NC 28584 Application Date: August 15, 1997 Water Body Receiving Stormwater Runoff: Cartwheel Branch Classification of Water Body: "SA" If Class SA, chloride sampling results: 18.7 ppm Pond Depth, feet: 5 Permanent Pool Elevation, FMSL: 30 Total Impervious Surfaces, ft2: 251,949 Outparcels, ft2 n/a Future, ft2 n/a Offsite Area entering Pond, ft2: none, per Engineer Required Surface Area, ft2: 17,783 Provided Surface Area, ft2: 21,185 Required Storage Volume, ft3: 20,873 Provided Storage Volume, ft3: 21,185 Temporary Storage Elevation, FMSL: 31.75 Controlling Orifice: 2.5" pipe 3 State Stormwater Management Systems Permit No. S y3 97084 5. The permittee is responsible for verifying that the proposed built -upon area does not exceed the allowable built - upon area. 6. The following items will require a modification to the permit: a. Any revision to the approved plans, regardless of size. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area. e. Further subdivision of the project area. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. In addition, the Director may determine that other revisions to the project should require a modification to the permit. 7. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. II. SCHEDULE OF COMPLIANCE The permittee will comply with the following schedule for construction and maintenance of the stormwater management system: a. The stormwater management system shall be constructed in it's entirety, vegetated and operational for it's intended use prior to the construction of any built -upon surface except roads. b. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 2. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of side slopes. d. Immediate repair of eroded areas. e. Maintenance of side slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device and catch basins and piping. g. Access to the outlet structure must be available at all times. 3. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 4. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 4 State Stormwater Management Systems Permit No. SWR 970834 5. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. 6. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction. 7. Prior to the sale of any portion of the property, an access/maintenance easement to the stormwater facilities shall be granted in favor of the permittee if access to the stormwater facilities will be restricted by the sale of any portion of the property. M. GENERAL CONDITIONS This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143- 215.6C. 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The penmittee grants DENR Staff permission to enter the property for the purpose of inspecting all components of the permitted stormwater management facility. 6. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. Permit issued this the 26th day of January, 1998. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION D--,1'S (� k'\r;z [— r= C, i A. Preston Howard, Jr., P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number SW8 970834 k, State Stormwater Management Systems Permit No SW8 970834 Pirates Cove Townhomes Stormwater Permit No. SW8 970834 Onslow County Engineer's Certification I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. Noted deviations from approved plans and specification: Signature Registration Number Date SEAL :2 DIVISION OF WATER QUALITY NORTH CAROLINA STORM nVATER rLA-NAGENMN"T PEE IT APPLICATION I. GENERAL INFOMMATIO\' (Please print eleerly or 0 pe) 1. Project Name_ PigPrc,5 dovg 2. Location, directions to project (include County, Address; State Road) Attach snap._ Pc�re55 Je rR m C�U;FNS CRFFI,' RoPio (NQ5R 1,501)) 0 -eS �; c:c ��lri/ (&THI1/D G'VgeL/L V J GnLP481R, ) 3. Owner's Name_ Pi,snr,, Coy-- 1.1-e. Phone 41Q_,3f13•-8o�'R 4. Owner's Mailing Address dol pgLL r-n P, Ccop Rcpn City Stilni:SriG.4^ State h'C� Zip 5. Nearest P.eceivirb Stream GRRtwH661- ffi4RN N Clays. �P s, 6.Projectdescriptionjoq uNlr rw.vigoese, tteyezoyMFNr gjag) 1VrtJ Ro?n5 PI..50 'T) 86 BL/47, 1a"00 6f c"I d0515 'E/0'15 Co✓RT CA :F1_10 'Q&1n/D • II. PERAJaT IYFORI4ATIOIN 1.Permit No.(lobefi11edinbyDw0 `3 A)g q.-7063¢ 2.ApplicationDate 8/;,/97 2s—q7� FeeenclosedS 3.PermitType:- X_New Renewal Modification (existingPermit No.) 4, Project Type: Low Density _,_Detention • Infiltration Redevelop General- Al � 5. Other State/Federal Permits/Approvals Required (check apprcpria:e blank,) p -,.� CAMA Major Sedimentation/Erosion Control X 404 Permit EAL � 5631 r III. BUILT UPON AREA (Please see NC.4C 2N.IfA! rhr:r .1C07jor a?p!!ec✓!e dsrsiry lin:iu) AGr����� ,,•• .• Drainage Drainage Breakdown of J ,Arl'LEP�� 1 +1++Allis+•``) Ba$!n Bzsln (Please & �iccre belotiv rJat :sign fn pensous area Classification Buildings. 310 SZ- Existing Built -upon Area Proposed Built -upon Area Total Project Area Built -upon Area Rey% M- 74--91 IV. STORIIWATER TREAT11Ei\Z' 0 25049�� ti74, So l s1= (Describe how Me r i1:0' k:a be heaved) Streets Parking/SW _ a1u6 ho�s� I hoc motet r/&t:4 CYWA1/5 eC4'•-r) Totals 2 51 , 9 49 sF i(N 10 -Z -0� 7 StcRm—'A C-h RuvaLF 7 f" DiRi-e571--n 8/ CdRh' w ut'iirf'i /,t; P, ip �Rr"PS AyD fN S,+Pl1 St-�Plf IN (iRF�SsE� Agg, & T ORrfH Rn5/r i i�r't % /n �� �� i�SPC r r�ur--, ✓ y N 9lyrD i %Yt�'Q��a-tn1iD ;5 PN ON Sri RcycNT/G.ti P--ND. V. DEED RESTRICTIONS AND PROTECTIVE COVENANTS Deed restrictions and protective covenants are required to be recorded for all low density projects and all subdivisions prior to the sale of any lot. Please see Attachment A for the specific items that must be recorded for the type of project applied for. By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the items required by the permit, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the covenant cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. VI. OWNER'S CERTIFICATION I, _—J_CZ PM en M, 4A vi",5 Y/, . certify that the"�lnformatioli included on this permit (Please print clearly or type) application form is correct, that the project will be constructed in conformance with the approved plans, that the deed restrictions will be recorded with all required permit conditions, and that to the best of my knowledge, the proposed project complies with the requirements of 15A NCAC 2H.1000. I authorize the below named person or firm to submit stormwater plans on my behalf. i1L u) C Owner/Authoriz,4J Agent Sign ture anle Date VII. AGENT AUTHORIZATION (Please fill in the tame of the engineerlsurveyor authorized to suGmle plant on the owner's helaf) Person or firm name _09RRl,66 R RRWkS qi- R656G1R79S Mailing Address _ -B maw ", c7 f . % Cl. floz City 501314s00o State rUC, Zip 98,6'814 Phone 9 o ­,3,,1— ///aLq Please submit application, fee, plans and calculations to the appropriate Regional Office. cc: Applicant/WiRO//Central Files S AUX _V51,96 rWJ 61-16�9 13:34 W B MCLEAN OFFICE 9B5 P611.0 TO: L.INDA Lewes, rmw ?Eylgw IDEFA 0 VJNj& CDUALIT�- _-WILMWGTD � � NC, FAX : , 91 o t' - z 4- FROM: JOHN P. MCI LAN, P.L. JGHN P. MCLEAN ENGINEERING ASSOCIATES TEL 919-393-2219 DATE; I- IG —q A TIME: Z: EM - COMMENTS PAX 919-393.246'3 NO- PAGES (INCLUDING COVER) ?— !. r // f A L.A 4. r � � A D ap'r WILL. Pbt.1.bUJ VIA USMAIL FAX TRANSMISSION F,le:FoR.a 01-16-36 13:35 W B MCLERN OFFICE 985 P02 A. B. C. D. E, v ti[urmwulrr Detention Basin rSEAL for Pirates Cove TownhousesSwtinaboro, N,C, rovi lon date 10-06-97 REVISION DATE 10.24.97 WAr Sample Calculations and Assumptions hq sr,nMsssawo Total site area = .474,501 sf (Charles Rawls & Assoc.) Total built upon surface = (sce following page) 251,949 sf (by Charles Rawls) Design for 905 Teti removal by detention basin Receiving waters urQ classificd us SA, but less than S ppi salinity Assumptions and Calculation,; Basin volume required between normal pond elevation & emergency overflow 474,501 x 1112 = 19,542 cubic feet Delcrttion basin surface area (SA) at normal pond clevation (00.0 ft) = 21,185 sf (exact computation from Charla..s Rawls, RLS) a No off site stormwater run-on, SA/DA % =(permanent pond surface area/total drainage are to detention basin) x 100 - 21,185 1474,501 x 100 — 4.45% % built upon area -P 2.41.9.19/474.501 x 100 = 53 % Minimum average depth of permanent pool required for detention basin (Driscoll model tables by DWQ) = 5.0' To sustain minimum average of 5.0', the minimum pool volume must be maintained greater than 79,474 (see work sheet below). From above, 39,542 cf of storage must be provided above the permanent pond clevation. a) side slopes are 2:1 helow the permanent pond level, and specific calculations are shown below (computations by Charles Rawls). Permanent Pond Surface Area volume Total Pool Storage Elevation = 30.0' 21,185 sf - = 20.0' 19,449 sf 20,317 cf Z0,317 cf = 28.0' 16,013 sf 17,731 cf 38,048 cf = 27.0: 14,$16 sf 15,264 of 53,312 cf = 26.0' 13,077 sf 13,796 cf 67,10.8 cf = 25.0' 11,697 sf 12,387 cf 79,495 cf So, the minimum pond dglth must be set at 25.0 feet STORMWATER p e c e i v e JAN 161998 D 1Z D E M PROJ # F. Side slopes above the permanent water level are 3:1, Ground Level Surface Area Volume Total Storage Elevation = 30.0 21,185 sf 0 0 = 31.0 23,812 sf 22,498 cf 22,498 cf = 31.7 25,728 sf 24,770 cf 39,876 cf Therefore, the emergency overflow height above the permanent pond must be set at say 31.7 feet. G. Size orifice for 2 day drawdown a) if 2 day draw down is assumed, avg. discharge rate = 39,542/24x60x60x2 = 0.228 cfs b) maximum orifice size from orifice formula : Q = CA (2gH) to 1/2 power where A = area of orifice, sf where H = head in ft. where C = 0.6 = 1.7 ft where g = gravity acceleration so: A = (0.228)/(0.6)[202.2][1.7] to 1/2 power = 0.0363 sf and D = 2 R so R = [A](144)/pi to 1/2 power = 1.29" therefore D = 2.58 inches Check orifice size by routing orifice at 12 hour intervals to assure drawdown is between 2 and 5 days. Set bottom of orifice at permanent pond elevation, assume ele = 30.0' Elevation Storage 30 0 30.5 11,234 cf 31.0 22,468 cf 31.5 36,400 cf 31.7 41,046 cf Elapsed time 0 hrs : 39,542 storage, H = 1.7, Q = 0.228 cfs Elapsed time 12 hrs: Approx. storage remaining = 39,542-(0.228x12x60x60) = 29,692 cf Approx. H = 1.42', Q = 0.208 cfs Elapsed time 24 hrs: Approx storage remaining = 29,692-(0.208xl2x60x60) = 20,706 cf Approx. H = 1.10', Q = 0.183 cfs Elapsed time 36 hrs: Approx storage remaining = 20,706-(0.183x12x60x60) = 12,800 cf Approx. H = 0.76', Q = 0.121 cfs Elapsed time 48 hrs: Approx storage remaining = 12,800-(0.121x12x60x60) = 7,572 cf Approx. H = 0.53', Q = 0.15 cfs Elapsed time 60 hrs: Approx storage remaining = 7,572-(0.15x12x60x60) = 1,092 cf Conclusion: drawdown exceeds 2 1/2 days and is less than 5 days H. Size of outlet device, is a 36 inch diameter overflow pipe with a calculated orifice size of 2.58 inches diameter. Because the drawdown obviously exceeds 2 days while using an orifice of 2.58 inches, the size shall be set at 2.5 inches diameter (see detail on plan). The drawdown will exceed 2 1/2 days and be less than 3 days. Set concrete overflow at elevation 32.0 feet, (6 feet wide, 4 inches minimum depth of concrete, flume directed into the existing ditch downstream of the pipe). Supporting Information by Charles Rawls, RLS Impervious areas 6 unit building = 4397 x 6 = 52,764 square feet 8 unit building = 5897 x 4 = 23,588 " " club house 1,600 square feet tennis court 7,200 " " sidewalks (5 feet wide) 24,908 square feet streets and park. 141,889 square feet Total 251,949 square feet Note: All details which were shown at this location in previous submittal, have been moved to "Erosion Control Retail Sheet" File: Piratese.ST3 i � J �,lS i7 ��J�S� '' ■ NOV 25 1997 TORMWATER , JOHN P. MCLEAN ENGINEERING ASSOCI 106 Manatee Street Cape Carteret, N.C. 28584 November 24, 1997 FAX: 919-393-2463 Tel: 919-393-2219 Ms. Linda Lewis, Stormwater Review Department of Environment, Health & Natural Resources 127 Cardinal Drive Extension Wilmington, North Carolina 28405-3845 Re: Stormwater Project No. SW8 970834 Pirates Cove Townhouses, Swansboro, Onslow County, N.C. Dear Ms. Lewis, This correspondence is in response to your letter dated November 13, 1997 1. We have placed a note on the drawing which specifies all building drains shall be directed into the paved areas. (Stormwater Notes on the Site Grading and Drainage Plan) 2. The building dimensions are now shown. There are no decks nor concrete areas for individual buildings. (Site Grade and Drainage and Site Erosion Control Plan) 3. In the Pond Section Detail: a. The width of the shelf is 6 feet and begin (+28.0) and end elevations (+29.0) are noted also. b. A trash rack has been provided for the 36" overflow riser. (See Erosion Control Detail sheet) c. The trash rack for the 2.5" orifice has been shown as we discussed (same detail). d. The forebay has been sectioned on the plans. (Detail Sheet) e. The permanent water level has been labeled at + 30.0 feet. (plan sheets and detail sheets) 4. The surveyor has again calculated the impervious areas and the total is hereby reported at 251,949 square feet. (see revised Sample Calculations and Assumptions). 5, Calculations showing the actual volume provided in the pond between the permanent elevation and the overflow elevation have been provided by Charles Rawls, RLS and the storage volume is 39,542 cubic feet. Thank you for your attention to this project. Happy Thanksgiving ! Sincer 'y, 7oh P. McLean, P.E. closures: 2 copies of plan sheets (Site Grading, Erosion Control & Details) Revised Application Sheet cc: Charles Rawls L.E.McNeill file: pirates.st3 State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office James B. Hunt, Jr., Governor Wayne McDevitt, Secretary Division of Water Quality November 13, 1997 Mr. John McLean, P.E. McLean Engineering 106 Manatee Street Cape Carteret, NC 28584 Subject: Dear Mr. McLean: NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES REQUEST FOR ADDITIONAL INFORMATION Stormwater Project No. SW8 970834 Pirates Cove Townhomes Onslow County The Wilmington Regional Office received previously requested information for the Stormwater Management Permit Application for Pirates Cove Townhomes on October 9, 1997. A preliminary review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: 1. As discussed in our meeting, please note on the plans that all roof drains must be directed into the paved areas, or provide swales at the rear of the buildings to pick up this water. 2. The typical building footprints on the plans are neither dimensioned nor noted with the covered decks, uncovered decks, and concrete areas. 3. Please revise the Pond Section Det4il as follows: a. Note the width of the vegetated shelf, and the begin and end elevations. b. Provide a trash rack for the 36" overflow riser. C. The detail of the orifice in the calculations indicates a 6" 90' elbow, but the riser detail on the plans indicates only a 2.5" hole in the riser. If .you choose to use the 2.5" hole in the riser, as currently depicted, then you need to specify a trash rack that can extend over the orifice. d. Include the forebay in the section detail. e. Label the "Water Level Elev. 30" on the detail as the permanent pool. 127 North Cardinal Dr., Wilmington, North Carolina 28405 Telephone 910-395-3900 FAX 910-350-2004 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper Mr. McLean November 13, 1997 Stormwater Project No. SW8 970834 4. The impervious area breakdown does not add up to the 259,939 square feet you show. All you did was revise the total. Please indicate the correct breakdown to reach the new total. 5. The orifice size is based on the actual volume provided in the pond between the permanent pool and the design pool. Since you have set the overflow at 31.75, the storage volume is in excess of 41,046 cubic feet. Please reevaluate the orifice size using the volume provided. Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to December 13, 1997, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you have any questions concerning this matter please feel free to call me at (910) 395-3900. RSS/arl: cc Sincerely, Ms. Linda Lewis Environmental Engineer S:\WQS\STORMWAT\ADDINFO\970834.NOV Linda Lewis Central Files 127 North Cardinal Dr., Wilmington, North Carolina 28405 Telephone 910-395-3900 FAX 910-350-2004 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper I 7 ' . . TV D ATE ST®RI oc Y o 9 1997 JOHN P. MCLEAN ENGINEERING ASSOCIATES 106 Manatee Street Cape Carteret, N.C. 28584 October 6, 1997 FAX: 919-393-2463 Tel: 919-393-2219 Ms. Linda Lewis, Stormwater Review Department of Environment, Health & Natural Resources 127 Cardinal Drive Extension Wilmington, North Carolina 28405-3845 Re: Stormwater Project No. SW8 970834 Pirates Cove Townhouses, Swansboro, Onslow County, N.C. Dear Ms. Lewis, This correspondence is in response to your letter dated September 11, 1997 1. The chloride content was sampled 1/2 mile as the crow flies, and concentration was found to be 18.7 ppm (See enclosed letter to Rick Shiver dated Sept. 3, 1997) 2. I've been advised by Charles Rawls, the "accessory use" has been defined as "playground" and we have only grassed areas, hence no impervious areas. 3. A signed Pond Maintenance Plan has been attached hereto. 4. Charles Rawls, RLS is the surveyor on this project and he has affirmed that there are NO 404 wetlands on this tract. 5. We have detailed the cross -sectional areas which were requested, ie, the bottom, top, 6:1 shelf, 3:1 slopes, 2:1 slopes, forebay, etc. 6. The outlet structure detail is also included herein. The apparatus is a pipe elbow, 6 inches diameter, field fit and fabricated for installation. 7. The permanent pool dimensions are shown on the plan. 8. The calculations reflect 259,939 square feet total impervious area as as calculated by Charles Rawls, RLS. 9. The minimum depth of the pond will be 5.0 feet. 10. Calculations for the drawdown are included on another sheet attached hereto. 11. All backslopes above the permanent water level are 3:1 maximum. 12. The runoff from the entrance road has been altered to capture the runoff as requested. 13. There are no swales (only those in the immediate vicinity of the yard inlet). 14. The pond dimensions are included on the plan as requested. I regret it took so long to respond to your comments and appreciate the telephone conversations. Thank you for your attention to this project. Sincerely, tt ;A J hn P. McLean, P.E. enclosures: letter to Rick Shiver dated 9- 03-97 (salinity investigation) pond maintenance requirements (signed) 2 copies of project plan sheets sample calculations/assumptions and details revised Stormwater Management Application (sheet 1 only) cc: Charles Rawls L.E.McNeill file:pirates.sltorm State of North Carolina Department of Environment, Health, and Natural Resources Wilmington Regional Office James B. Hunt, Jr. Division of Water Quality Wayne McDevitt Governor. Water Quality'Section Se=tary September 11, 1997 Mr. John McLean, P.E. McLean Engineering 106 Manatee Street Cape Carteret, NC 28584 Subject: ACKNOWLEDGEMENT OF RECEIPT AND REQUEST FOR ADDITIONAL INFORMATION Stormwater Project No. SW8 970834 Pirates Cove Townhomes Onslow County Dear Mr. McLean: The Wilmington Regional Office received a Stormwater Management Permit Application for Pirates Cove Townhomes on August 15, 1997. A preliminary review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: ✓ 1. This project drains to SA waters. Please provide the results of a chlorides test taken at a point in the receiving waters that is 1/2 mile as the crow flies from the proposed discharge point. The sample must be taken after 3 days without rain. Assuming that the sample comes back at less than 500 ppm, the remaining items to be addressed follow. 2. What type of pavement does the area labelled "Accessory Use" at the end of cul-de-sac have? Please remember that any area used for parking or subject to vehicular traffic is considered impervious. V 3. A signed Operation and Maintenance Plan, enclosed. J 4. Delineate all wetlands on site, or note on the plans that none exist. 5. Provide pond details on the plans, including a section with the bottom, normal pool, design pool and top of bank elevations; 6:1 vegetated shelf, forebay, and 3,1. slopes above the permanent pool noted. 6. Provide an outlet structure detail with the orifice size and type of trash rack noted. 7. Provide dimensions for the permanent pool. 127 Cardinal Drive Extension, WilmingM N.C. 28405-3845 • Telephone 910-395-3900 • Fax 910-350-2004 An Equal Opportunity Affirmative Aeon Employer Mr. McLean September 11, 1997 Stormwater Project No. SW8 970834 8. The calculations use 248,069 square feet in determining the pond size, the application lists 253,148 square feet, and my calculation indicates 255,000 (including "Accessory Use" area). Please check your calculations and revise accordingly. 9. If you must work backwards to see if the available surface area in the pond will meet the required surface area, please choose a depth from the chart of either 3.5 or 4, not 3.8. 10. Most engineers calculate both the 2 and 5 day drawdown orifice sizes and choose a readily available stock size in between such as 1.25", 1.5", 1.75" etc. Specifying a 2.66" orifice seems a little unnecessary when a stock size of 2.5" would do the job just fine. Additionally, the head used in the orifice calculation is an average head measured from the design pool elevation to the center line of the proposed orifice. 11. The road detail indicates cut/fill slopes of 2:1. The regulations require all vegetated slopes to be 3:1 or flatter. Please revise. 12. It appears that runoff from over 9,000 square feet of entrance road is allowed to leave the site untreated. Please pick up this runoff and get it to the pond. 13. Where are the graded swales that are referred to on the application that pick up runoff? The grading plan does not indicate any swales. 14. Delineate, label and dimension the permanent pool Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to October 11, 1997, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you have any questions concerning this matter please feel free to call me at (910) 395-3900. Sincerely, , Ms. Linda Lewis Environmental Engineer RSS/arl: S:\WQS\STORMWAT\ADDINFO\970834.SEP cc: Linda Lewis Central Files FA JOHN P. MCLEAN ENGINEERING ASSOCIATES 106 Manatee Street Cape Carteret, N.C. 28584 Tel: 919-393-2219 Fax: 919-393-2463 Email: ladymcl@bmd.Clis.com September 3, 1997 Mr. Rick Shiver, Water Quality Supervisor Dept. of Environment, Health and Natural Resources 127 Cardinal Drive Extension Wilmington, N.C. 28405-3845 RE: Pirates Cove Townhouses, Swansboro, Onslow County Classification of downstream waters request Dear Mr. Shiver, Attached hereto you will find an application for a housing project (public sewers) within the City of Swansboro for classification of the watershed downstream waters. For your information, I have enclosed the results for a sample tested approximately 2,000 feet frond the intersection of SR 1737 and NC 24 which is approximately 1/2 mile from the project in Cartwheel Branch. The sample was taken by Dan. Fortin (licensed operator) and tested at Beacham Laboratory in Jacksonville. The chloride level was shown to be 18.7 ppm. If there are any comments or questions, I will be glad to discuss there with you or one of your staff. Please respond when you have been able to address this matter. Sincerely, IcLean, P.E. enclosure: Application (Sheet 5 of 8) USGS Hubert Map (1"= 2,000') Copy of Memo to Dan Fortin Beacham Laboratory Report cc: Bill Price, Town Manager Charles Rawls, RLS file: Pirates. W QS This form must be completed by the appropriate DEh1 regiona"l office and included as a part of the project submittal information. INSTRUCTIONS TO INC PROFESSIONAL ENGINEER: The classification of the downslope surface waters (the surface waters that any overflow om the facility would flow toward) in which these sewers will be constructed must be determined by the appropriate DLM regional office. Therefore, you are required, prior to submittal of the application package, to submit this form, with items 1 through 7 completed, to the appropriate Division of Environmental Management Regional Water Quality Supervisor (see page 8 of 8). At a minimum, you must include an 8.5" by 11" copy of the portion of a 7.5 minute USGS Topographic Map which shows the location of these sewers and the downslope surface waters in which they will be located. Identify the closest downslope surface waters on the attached map copy. Once the regional office has completed the classification, reincorporate this completed page and the topographic map into the complete application form and submit the application package. 1. Applicant (specie name of the municipality, corporation, individual, etc.): BILL Pf;ce , Town) MmAGEL SWA�J5&oP-D..M.G . 2. Name & complete address of engineering firm: Telephone number. ( 3. Project name: °) I9 4. Name of closest doe,-nslope surface waters: 5. County(ies) where sewers and surface waters are located: 6. Map name and date: _ 0el(s " 7. NC Professional Engineer's Seal, Signature, and Date: John MCLe( Wo MAn BAR-MF�EEL. oms J -•• y r''''r•� P McvE;-g 4'1911W 1000 TO: REGIONAL tiN'ATER QUALITY SUPERVISOR W9 Please provide me with the cLassification of the watershed where these sew•-n will be constructed, as identified on the attached map segment: Name of surface waters: Classification (as established by the Environmental Management Commission): Proposed classification, if applicable: Signature of regional office personnel: Date: FORM: GSPSA 02/95 Page 5 of 8 JOHN P. MCLEAN ENGINEERING ASSOCIATES August 13, 1997 Ms. Linda Lewis, Stormwater Review Department of Environment, Health & Natural Resources 127 Cardinal Drive Extension Wilmington, North Carolina 28405-3845 Re: Stormwater Plan Submittal Pirates Cove, Swansboro, Onslow County, N.C. Dear Ms. Lewis, 106 Manatee Street Cape Carteret, N.C. 28584 Tel: 919-393-2219 Fax: 919-393-2463 `V v V Enclosed herein you will find a Stormwater plan for Pirates Cove, a townhouse project within the City Limits of Swansboro, on SR 1509 near the new high school. I have provided herein a check in the amount of three hundred eighty-five dollars ( $ 385.00) and other items shown on the Table of Contents enclosed herein. Please comment when you have had an opportunity to review these items. Sincerely, J hn P. McLean, P.E. enclosures: noted cc: Charles Rawls L.E.McNeill ORMWATER AUG 15 1997 file:Pirate.storm Stormwater ManaggM tEeMit Aaaiicpjon Pirates Cove Swansboro Township Onslow County, North Carolina CAR Project ft 97.1537 August 15,.1997 Table of CoOn11 1. Narrative 2. Construction Sequence 3. Vicinity Map 4. USGS Map (Hubert Quadrangle) 5. FIRM Map (Community Panel Number 370340 0360 C) 6. Soils Map 7. Seeding Schedule and Specifications 8. Drainage Area Map 9. Impervious Surface Area Map 10. Area and Runoff Coefficient Calculations 11. Storm Drainage ScheduletCalculations 12. Storm Drainage Schedule (Formulas and Column Descriptions) 13. Rainfall Intensity Duration Curve - Wilmington 14. Design Storm Source Data for Wilmington, NC (prepared by H.R. Malcom) 15. Sample Calculations 16. Stormwater Detention Basin a) Sample Calculations and Assumptions b) Maintenance Guidelines and Schedules ^ STORMWATER 17. Deed 18. Stormwater Management Permit Application E C E I V E elan Sheets D 1. Standard Symbols and Abbreviations AUG 151997 2. 3. Site Layout Plan Site Grading and Drainage Plan M 834� # SW 1 4. Site Erosion Control Plan PROJ 5, Pavement, Sidewalk and Curb & Gutter Details 6. Stormwater Drainage Details 7. Erosion Control Details August 12, 1997 Pirates Cove Swansboro Township, Onslow County, North Carolina NARRATIVE: This property is approximately 11 acres, located on SR 1509, directly across the Queens Creek Road from the new Swansboro High School in Onslow County. Access to the property is via a 50 foot wide R/W as shown on enclosed maps. The project is within the City Limits of Swansboro and therefore within the Swansboro Planning Board jurisdiction. The owner of the tract is: Pirates Cove, LCC % L.E.McNeill 601 Peletier Loop Road Swansboro, North Carolina 28584 Phone No. 919-393-8058 All of the tract will be disturbed, approximately 10.5 acres. Since the tract has a 1% grade naturally, significant fill is required to provide proper drainage. A check is enclosed herein for two hundred thirty dollars ($ 230.00). The development plans include construction of a street system as shown on the attached maps. The entrance road is 50 feet wide. The usual DOT requirements will be met with regard to horizontal and vertical alignment. Application has been made for an entrance permit from SR 1509. The surveyor is: Charles Rawls and Assoc, RLS P.O. Box 1126 Swansboro, North Carolina 28584 910-326-1408 The engineer is: John P. McLean, P.E. 106 Manatee Street Cape Carteret, North Carolina 28584 919-393-2219 There are no 404 Wetlands on this tract. A topographic survey has been prepared by Charles Rawls,RLS.. The flood map indicate all of the property is in a Zone C. (See FIRM Map No. 370340-0360 C (Dated 07-02-87) Onslow County, N.C.). Adjacent Property: The property is located southwest of the new Food Lion on NC 24 near the SR 1509/NC 24 intersection. All other adjacent property in the vicinity is residential or agricultural use. Soil Conditions: This property is shown on an enclosed sheet of the Onslow County Soils Map ( USDA ). It is predominately Onslow Soils ( loamy fine sand ), characterized by nearly level, moderately well drained soil. Part of the tract under consideration is classified as Rains ( fine sandy loam ). These areas are nearly level poorly drained soils on uplands. Development Notes: The owner intends to clear the site, add fill as required to meet design grades, excavate the detention pond, construct streets, building pads, and associated site work to effect the drainage plan. Application for a driveway connection has been made to the Department of Transportation. There is a requirement for 60 lineal feet of 18 inch diameter reinforced concrete pipe in the gutter line at the entrance to the property. Planned Sedimentation and Erosion Control Practices 1. 2. 3. 4. 5. Construction Entrance: A typical construction entrance shall be constructed at the entrance to the property as detailed. Silt Fence: This measure is planned for the entire perimeter. The contractor shall exercise caution to ensure proper installation. No site fence is to be installed in ditch lines or at pipe outlets, etc. Temporary Sediment Basin: The wet detention basin will be over excavated to provide for 19,800 cubic yards of storage for temporary sediment. Yard Inlet Protection: There shall be rock/filter devices installed to ensure silt is restricted from entry to the pipe system (See plans). Block and Gravel Inlet Protection: At each catch basin and drop inlet, sediment will be restricted by the use of block and gravel devices prior to vegetation stabilization at the site. File: PiratesCover.S&E CONSTRUCTION SEQUENCE 1. Obtain Sedimentation and Erosion Control Plan Approval before any other land disturbing activities begin. 2. Install construction entrance and pipe at SR 1509 (see detail). 3. Begin clearing operations in roadways, remove vegetation, pile and burn debris if permitted (haul to approved disposal site if burning is prohibited). 4. Install any sediment control measures where practical as construction progresses. Pay particular attention to silt fences (first measure). 5. Excavate detention pond/sediment basin as detailed, exercising care to store material for drying in an .area (which is protected by silt fence or swales), while not allowing sediments into adjacent areas. 6. Grubbing and grading shall be done carefully only if the project is protected so any sediment runoff stays on site. 7. Install utilities (water, sewer, electrical lines, telephone, cable) Install protection devices to retain silt from interior of all pipes. 8. Careful coordination is required to install all transmission pipes while other work may be progressing. 9. Haul additional fill material to site for building pads etc. 10. Fine grade streets, parking areas and building pads. 11. Apply seed, fertilizer and mulch (mulch all slopes of 4:1 or greater). 12. Install marl street base (6" minimum compacted depth of CABC). 13. Install I-2 asphalt paving on streets and parking. 14. Dress all bare areas, remove any remaining root mat etc, and reseed as necessary to provide vegetative ground cover. NOTE: Any area brought to final grade shall be seeded or sodded upon completion. Hollynlle 'cash Cwne •. • \ ".eft CFn lanero •/ . le, Um,nnesolt a r Nr i BePch ivap,n Catherine t ake�? p N + Jac .press •` reek ,�s I T'E \� �r WWII. end �.�rrr n..-.'. .••••• / � i •/ 1f.p.o�d a.vch Arcnf RH ol I if. Noflh Topsail Beach VB.".cCh"' 9-1 a.xh AttuAII ISLAND 3mgslea I� ()Id T„p•.,il lnly, VE R H:,h Inle, N.. •.n Inl; r �Whghtsvdle Beachf ,.rrF,.ri. !n!.•r USGS MAP - HUBERT QUADRANGLE SCALE: 4" = 2000' �,\i. ���' � - •4 a � Ins [. �(�J ,.�dl'. J, .ly � •,1 —�by — ., eq' Zi� _ _ (, _ 4 —. i. � �N �� `• � S£ Qom@ j � '. 4 ' ; . 13 1 • � � v'�� 5 � r �o 1 SITE �s2 1� � •- ? 4� i^ -a- - -' .35 II hh j 'P4 �r�vvrr 1 n d spa , ti J: . .�� i - - o •'I JA � ao 50 /r %I r! �il!I'e!!Cril NATIONAL EL000 INSURABCE PROGRAM I ONE 8 )NE A9 :EL 10} ENE B Ir FIRM FLOOD INSURANCE RATE MAP _ =� v M1) P ONSLOW COUNTY, NORTH CAROLINA y ,L', :SCORP0R 1TEn AREAS) PANEL 360 OF 556 Illlll�l�jf COMMUNITV•PANEL NUMBER 370340 0360 C EFFECTIVE DATE: / IULY 1, 1987 Federal Emergency %ts-gemwc At ZONE C \(z I // SR 14 5 1 VA ZONE (EL ZONE ;LOW COUNTY, NORTH CAROLINA - SHEET NUMBER 37 0 i 2 MILES 1 2 KILOMETERS cra+F I iG ;r;, SEEDING SCHEDULE Shoulders, roadside ditches, slopes (max 3:1) Date Type Planting Rate Mar 1 - Apr 15 Fescue 120 lbs/acre Apr 15- July 30 Hulled Bermudagrass 12 lbs/acre Apr 1 - July 15 Sericea Lespedeza 30 lbs/acre Sept 1 - March 1 Unscarified Sericea seed 30 lbs/acre August 30 - March 1 Hulled rye (grain) 25 lbs/acre Slopes (2:1) Mar 1 - June 1 Sericea Lespedeza 50 lbs/acre and Tall Fescue 60 lbs/acre Mar 1 - June 30 Hulled Bermudagrass 12 lbs/acre August 30 - March 1 Hulled rye (grain) 25 lbs/acre Additional information is available for different grass varieties, by consulting the local Soil Conservation office in Onslow County. The seed schedule offered herein is sufficient for local conditions. Allow Sericea to reseed by not cutting until the fall season and plants are mature. 1. 2. 3. 4. 5. 6. 7. SEEDING SPECIFICATIONS Chisel topsoil and scarify if necessary to prepare seed bed. Rip the entire area at least 4 inches deep. Remove all rootmat, debris or foreign material, leaving surface reasonably smooth and uniform. Apply agricultural lime, (in absence of soil test, 3,000 lbs per acre) fertilizer (10-10-10at a rate of 500 - 1,000 lbs/acre) and mix with soil. Apply seed on freshly prepared bed and cover seed slightly with cultipacker or other seeding equipment. Mulch immediately w/ wheat straw or hay (at a rate of 4,000 lbs per acre). Crimp mulch with anchoring equipment or with disk set generally straight. Inspect all seeded areas and make necessary repairs or reseeding within the planting period. DRAINAGE AREAS 50ALE: 1' = 200' IMPERVIOUS SURFACE AREAS SCALE: I' = 200' m C4 NOfO+�Ci�� "UtA�tQN W rt�Nlnt�11W�,I+NN� r pll'��COI�I�P+cOta : �kk V O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 rrre--rrrr-re-T V-%-rr T V.-rT e-rrrTrre� a- C C C a C a O C a C O C a G a G C C a a a a a a a a a c e9 N Q) N �t Q I� O C? cD N p Oo In N 0 0 0 0 G� M O O CG O W T �CD �CiOOrO�`-TOr r00O�'^ TOOOOrrLfyi� Ot"O N Or-OaOCOCaO00000OaC?COCOC?OOcV O�ttC1F �J �cpO ccoo �p © NN��OCcOOV-C?C�ONOON�c]N� �N�cpetOp� M4APO- `CONDN 14-COr C'' V V NMN`_`r`tNN ��A MLL W T t+ ua) W u)w) w) d?tb t pen4) lo w) q) u)uw)6�W ') wLoInWIn WCR W WS 0) O)WWMW0)WW0)W W W W WO a 0 a a 0 a 0 a G a o a a a O a a a a C 0 0 a 0 a t� OI.- MCO0 -tnd gppppQ��ooN ttl�O - OW) (COMtfitn!''l��yyapw V T- V- O O V M V- r O 0 V it N N Vr O V 04 N P► 3 . a C a a C O a a a a a a (3 a a a a a (S p a p a a a a 0 ui C? o a i E ONoOh.Ocpoll�P•rOCOM O�li�-ram�}} Nf�rr��pp�}O W cM�N�tn�O stN�p Os TN er�ta Ci� t0LC?e�}rtOT co Met�nl+ (�rt}�} CA N W tp �TO W vW) y1��co O I-NLOc9 1�1COMM tn�M h OOOIt%-0)0 N rr r Teter rrt-- N °`r- (V rN LO V toOeNNNOMC 0) to NOtLO%V)NNT-O.M�N01*O0o a r aO a a a a 0 a a a Q a a a a a a a a 0 a 0 0 CM a 4 I+ e MN O O .-q0 MWI.- OOMNNeWAt O tiNI coNtr� V-e-RR r-V- e-pL0))O �imD ~C LL NtiMOWMtt ttrMMcOMNIVtAT CN NN%- Cq qr r�Ot �pt I6a'3 T r e• OCrNClVk COI-CO(�OTNM�+CLo t"NM�}1pCp1�0oC7,�..Orrrrt+TT _y V-e- NNNNNNNCq C4K�8 Q NfY��a08 V� /V 8P7� V NV I 0:1ie Owl i� I-!r 8A88 tz Izh rz NWN a6 ODn � Oi Itz Oi m M A ai cq to (V (9 Ol O C4 M M !1 6 6 1 w 1� iY aQ, 1L ��ovvtp N Nl+7 cm N NNNN �� �ovv NN r' Egg NNcNv B t9 W� t0 'Q aD m O b O m y fV fit) Itl N O W7 d t1A tG � tV C � V m lV ed SS88 S SBY���9idiZ S 88 8 8%m 8 88 8 8 C;ci m a do-oq-4 d dd 6 d- evi d dd d o Q = n �afOi.,e`S�`�, .= N M 4,6 w o� w w i4 v) w w c4 Q T N g C C d C d d O d d d d 0 6 d d d O d 6 0 Q d d d d Gi it SmSSB vavved v vvvvvMM a vv v 444 v av 4 �r r� MQ1 IL po 9O M pp gqCpPg M2p ON 8 8gm O C q 8 po y{p QQ999 9 9 99 �o pg rs Of p S-rp m. sv O 8P4 pp 8m M p O N ppO 8 d d i 88888 8 8888888 8 88 8 888 8 88 8 8 0 �j 999m94D 99 9Mo t9c09988 8 99 9 cantan9 9 99 9 9 E O N Q O NM Pf V d OOOOw'-a= d 66 d q d d d d O 4 M �E FQ r` o rqu < r w - � OL p [y �n 0 a" �i 4 ry N Ip �G 0 Q 00 W W N f V C1 Nf iY v.$ v U co 00 vo a r, a !V o O to co L O _M o 1O wO�ile F od fit; a .. ! •aci ra _ X� h J S% a 61 y wNM�1r w o me j �vv r me-+ m e R& N N A t^`I R r, L 7 MPf Y1N� t9 Mm Nw.1Ntpn R1 011+1 .7 FF d o C o c o c o c c c o c c o q c d o d o d o p c V l3��468 fii R�vi�vivir fii i3 �r� F3 t3R �iM� rvi�ivivi� cd vi *A ,+m YM3 Cj 06 ddEMd. d dd G C.dO O d0 O O m 1 - 2.,._. m W aoq C MN NS W Ap Y tRpl N E vp m 99 w A vi O O O o M O o O 0 o 0 o o O so O O O O O 02 O p c 66566 O 9996669 O 06 O 000 O so O O d COG C O d d d d d d d O d d d d C d d d d d 6 I cgcgqqwm o wwmory+Rn p nM q ll mot- s to co Q d A g g cn 99 IL- 0.0 tsi, e+l 1+3 [O M 1+1 ir�f {�� e.�f iN�i bf Rl M W Pf trPl t�y co 9 M 9 I- �Nj (V Nsn 9 8ml7l'4OfN0 s 8 AO (% �V7 9 T og mV as M R PM] V R M � 2 V% -r V p .- % m N e V IV 8m O^ O N rr p p O O O d ddd d o d O G d O O Ciw d d F N O O 4 8 9 9 f 8 m 88 m G :: F! r p C V 4 M vi Pi 4 V < 6 m Cq Ni of vi P'7 +f at Hi elm Oi 4 i STORM DRAINAGE SCHEDULE Formulas and Column Descriptions Rational Method per H.R. Malcom, P.E. PROJECT NAME: Pirates Cove PROJECT NUMBER: 97-1537 DATE: August 11, 1997 FROM - The designation of the structure at the upper end of the pipe. TO - The designation of the structure at the lower end of the pipe. AREAS - The drainage areas contributing to the upstream end of the pipe (the designations of the inlets contributing flow, not including side stream flows). TOTAL AREA (AC) - The total area draining to the upstream end of the pipe. INLET TIME (MIN) - Flow time on the ground to the most remote inlet upstream of the pipe of interest. This Is the time of concentration for that Inlet. PIPE TIME (MIN) - Sum of the pipe segment times to the pipe being sized. TIME OF CONCENTRATION (MIN) - The longest flow time of all possible paths from the most remote point in the system to the upstream end of the pipe being sized. (I; ; Time -1 Pipe Time) INTENSITY (IN/HR) - The rainfall intensity for the design storm of interest (10 yr. storm) and the time of concentration. where: I = g/(h+Tc) I = Rainfall intensity (in/hr) Tc = Time of concentration (min) g = 252 h = 30 (g & h are locally specific constants, the values shown were computed by H.R. Malcom for Wilmington, NC) RUNOFF COEFFICIENT - The composite runoff coefficient for the contributing drainage areas. Cc = Ci Ai E Ai where: Cc = The composite runoff coefficient (dimensionless) Ai = The area of an individual category of composition Ci = The runoff coefficient for the individual area DISCHARGE (CFS) - The design discharge. where: Q=CIA Q = Discharge (cfs) C = The composite runoff coefficient I = Rainfall Intensity (in/hr) A = Total drainage area (ac) SIDE STREAM (CFS) - Additional contributing discharge. TOTAL DISCHARGE (CFS) - Discharge plus side stream discharge. SLOPE (FT/FT) - Invert slope of pipe. CALCULATED DIAMETER (IN) - Theoretical calculated minimum pipe diameter. where: D = 16 [(Qn)Ns]3'8 D = Theoretical pipe diameter for just full flow (in) Q = Discharge (cfs) n = Manning's roughness coefficient (dimensionless) s = Slope (ft/ft) ACTUAL DIAMETER (IN) - Actual diameter of pipe to be used. CAPACITY FULL (CFS) - The amount of discharge the actual pipe to be used can handle for just full flow. where: Q=(1.49/n)AR23S". Q = Discharge (cfs) n = Manning's roughness coefficient (dimensionless) A = Cross sectional area of flow (so R = Hydraulic radius (ft) S = Slope (ft/ft) PERCENT FULL (%) - Actual discharge flowing through the pipe divided by the pipes full flow capacity. VELOCITY FULL (FT/SEC) - Full flow average cross sectional velocity. where: V = -Is D' 8.9n V = Full flow velocity (ft/sec) D = Pipe diameter (in) s = Slope (ft/ft) n = Manning's roughness coefficient (dimensionless) LENGTH (FT) - Length of the pipe segment of interest. SEGMENT TIME (MIN) - Flow time through pipe segment of interest. (Length) / ((Velocity) * 60) UPPER INVERT (FT) - Invert elevation of the upper end of the pipe of interest. LOWER INVERT (FT) - Invert elevation of the lower end of the pipe of interest. UPSTREAM TOP ELEVATION (FT) - Ground elevation at upstream end of pipe. Top of curb elevation for catch basins and curb inlets. Top of grate elevation for yard inlets. PIPE TYPE - Type of pipe being used. RCP = Reinforced concrete pipe CPP = Corrugated plastic pipe (Double Wall) MANNING'S COEFFICIENT - Manning's roughness coefficient (dimensionless). An experimentally determined value which is a function of the nature of the channel lining. n = 0.013 (RCP) = 0.010 (CPP) AREA ADDED (AC) - Additional drainage area being added. Cc ADDED - The composite runoff coefficient for the area being added. CROSS SECTIONAL AREA (SF) - Cross sectional area of flow. A=itr where: A = Cross sectional area (sf) r = Pipe radius (ft) HYDRAULIC RADIUS (FT) - Found by dividing the cross section area by the wetted perimeter. R=A/(2nr) where: R = Hydraulic radius (ft) A = Cross sectional area (sf) r = Pipe radius (ft) Appendices 20 15 IQ Wilmington 8i I �� j It, I I . :3 6 0 s n 4 t U c 2 cn C °D I 0.8 c13 0.6 c as X 0.4 NPI 0.1 L 5 10 20 40 60 2 3 4 6 8 12 18 24 Minutes Hours Figure 8.03b Rainf4ll intensity duration curves —Wilmington. 20 15 10 6 6 0 4 N s U c 2 U) N I 0.8 CIS 0.6 C CO 04 Ir 0.2 0.1 5 10 20 Minutes Figure 8.03c Rainfall intensity duration curves —Hatteras. Duration m��■wl M_ WI©..,.,,■.I 40 60 2 3 4 6 8 12 18 24 Hours Duration 8.03.5 J 9 V z C W O. 7 u 2 2 N = Ca! LOI � •O C W -••• S U 0 a U I 2 I g Z O Uz R IT L U � Z LU 1 t c T C'! zLU Q E N lL _� Z E U t � f rcc a 0 1 ■ t r1 R N CO Z } W Z II 11 II Lt• II O�MWtO N.D PInO 11 �C 11 9v1001-I9 11T OInO 11 O✓ 11 O'^ N v vW%^ O O II � 11 11 11 II 11 II 11 II L 11 �t OPNO t,_1 OO PM•O 1100 MP 1T IAO III I O•• •' I I O-- N M �t �t • O A P N II I W P.T •O� NN�P.O'- I.O�In�t�tP�t000 II I 1 C; NM M'T IA BOO I I I OII.1.O N1, N I 1 I d9MOOn tl I I In•O OOO M 0P 00►- 1 InPNPtnPN NOOO 1 OOr-�-•N NMdIA 1n I P�TP OOO.OMOO 0 i �T ON M•OMPIn 1 00�'•-NNNMM �T 1 ii E E E E Est.C== I N'IO t2 NM•0��? 11 M .O N 11 N I II I L 11 N II I II ✓ I II I II I 11 I L\ I ✓ I 11 I 3 O en N c• ¢ Za� O S •D >V NZ C: e=d U •fl a� a: O ¢ >. cd z ¢1u;a � L. 45 ',� CQ E �¢3 3 �. ¢ _ 0 c I.. N 0 > z Od E OG C v = T O = •i a� 1 OIA N%C EOr-Nq0 N 1 •O v M P OO t 1 0. W N N V N -- O O 1 I P O• In .t O P In N It co to A V CO . 10 O .O In t wN.aM Mm_: -:O p I V1M I--N .O I\In NM 0• V P In Ml aor�.ovr'i.-�000 MOIn V1NI�IAO 1>DM I NM�tN P.ONOO SIN I h•OIn'tr C;OO I I M•O t, 1�OO.. OO I", OO N 'T I •Oh PInv•-•1�.tN 1 OaOOM.•-�OO�=�MP i N V1 �tM Na-0000 II E•E•E EEttttr N�^IO�NM`O^ N 11 0 T ai � N N O C N N d L O f'1 O w o O o O E m O � 0 N O ym , ^ 1C•• L cu Q 3: cc m Eli u 11 II 11 'T GOON M'T II II 11 N N M M M M 11 II 11 11 II II 11 II 11 II 11 11 11 11 II 11 II 11 11 C II CI 11 PNO co •O 11 11 I l ti LA 0 M I P 11 C •E II II �NNN1 In In 11 O O II II 11 11 •4' t N 11 II 11 M L V 11 11 11 7 I.- 11 OC II N{A In OO 11 W In In 11 11 r-N InO 11 � 11 L II II 11 11 O O 11 11 11 •••• w II II 11 11 II 11 1 v I u I 0 I W P P O O I .TOM I O r•N�t 1 c C C i E E'Et i In ��N I 6 a p V PLE C.PLCOlA'TIgVS — PIR&TES CovE 'f12ACT SIZE 10. Sq � � U 1 R E) -�N- ACe-E Z 0 -r6Ar _ 304 10(zo)= �► . P�EQUIC��EO � � 1�-M�. S �. R�TENi�O� cF Stormwater Detention Basin for Pirates Cove Townhouses Swansboro, N.C. Sample Calculations and Assumptions A. Total site area = 474,501 sf (Charles Rawls & Assoc.) B. Total built upon surface 248,069 sf " if of C. Design for 90% TSS removal by detention basin D. Receiving waters are classified as SA, but less than 5ppt salinity E. Assumptions and Calculations: Basin volume required between normal pond elevation & emergency overflow = 474,501 x 1/12 = 39,542 cubic feet Detention basin surface area (SA) at normal pond elevation = 22,750 (estimated from Charles Rawls map) No off site stormwater run-on. SA/DA % _ (permanent pond surface area/total drainage are to detention basin) x 100 = 22,750/474,501 x 100 = 4.79 use 4.8 % built upon area = (248,069/474,501 x 100 = 52% Minimum average depth of permanent pool required for detention basin (by linear interpretation of Driscoll model tables by DWQ) = 3.8' To sustain minimum average of 3.8', the minimum pool volume must be maintained greater than 22,750 x 3.8 or 86,450. From above, 39,542 cf of storage must be provided above the permanent pond elevation. Permanent Pond Surface Area Volume Total Pool Storage Elevation = 30.0' 22,750 sf - - = 29.0' 21,560 sf 22,154 cf 22,154 cf = 28.0' 20,400 sf 20,980 cf 43,134 cf = 27.0' 19,274 sf 19,837 cf 62,971 cf = 26.0' 18,179 sf 18,726 cf 81,697 cf = 25.0' 17,116 sf 17,647 cf 99,344 cf = 24.0' 15,972 sf 16,544 cf 106,526 cf So, by interpolation, the minimum pond depth must be set at 25.77 feet and for temporary storage for sediment detention, the minimum depth must be set at 24.57 feet. F. Side slopes above the permanent water level are 3:, below the permanent level are 2:1 Ground Level Surface Area Volume Total Storage Elevation = 30.0 22,750 sf 0 0 = 31.0 24,596 sf 23,672 cf 23,672 cf = 32.0 26,513 sf 25,555 cf 49,226 cf Therefore by interpolation, the emergency overflow height above the permanent pond must be set at 31.62 feet. G. Size orifice for 2 to 5 day drawdown. a) if 2 day draw down is assumed, average discharge rate = 39,542/1440 x 2 = 0.21 cfs b) maximum orifice size from orifice formula Q = CA (2gH) to 1/2 power where A = area of orifice, sf where H = head in ft. where C = 0.6 = 1.62 ft where g - gravity acceleration so: A = (0.211)/(0.6)(2<32,2>x1.62>to 1/2 power = 0.0388 sf and D = 2 R so R = 44(144)/pi> to 1/2 power = 1.33" therefore D 2.66 inches Check orifice size by routing orifice at 12 hour intervals to assure drawdown is between 2 and 5 days. Set bottom of orifice at permanent pond elevation, assume ele = 30.0' Elevation Storage 30 0 30.5 11,836 cf 31.0 23,672 cf 31.5 36,449 cf 32.0 49,226 cf Elapsed time 0 hrs : 39,542 storage, H = 1.62, Q = 0.237 cfs Elapsed time 12 hrs: Approx. storage remaining = 39,542-(0.237x1440) = 29,303 cf Approx. H = 1.44', Q = 0.24 cfs Elapsed time 24 hrs: Approx storage remaining = 29,303-(0.224x1440) = 19,626 cf Approx. H = 1.16' Q 0.201 cfs Elapsed time 36 hrs: Approx storage remaining = 19,626-(0.201x1440) = 10,942 cf Approx. H = 0.46, Q= 0.121 cfs Elapsed time 48 hrs: Approx storage remaining = 10,942-(0.121x1440) = 5,714 cf Approx. H = 0.241, Q = 0.0917 cfs Conclusion: drawdown exceeds 2 days and is less than 5 days H. Size of outlet device, is a 36 inch diameter overflow pipe with orifice of 2.66 inches diameter. (see calculation of flow on Sed. and Erosion Control Plans) Set overflow at elevation of 32.0 feet, properly cemented in place as shown on the plan. Maintenance Guidelines and Schedules 1. Remove all sediment from basin to provide minimum design depth prior to final basin stabilization. 2. Stabilize detention basin embankments with vegetation within 30 working days of grade completion. 3. Inspect embankments weekly, for first year. Reseed and fertilize as needed to assure stabilization. 4. Mow portion of embankment at least annually to control the natural growth of trees. 5. Introduce top water minnows (Gambusia affinis, or commonly called mosquito fish) to control mosquito breeding in the permanent pond within 30 days of construction of the basin. 6. Inspect annually and drain the basin to remove accumulated sediments. 7. Inspect monthly during spring and summer seasons for debris that may reduce hydraulic efficiency or near the overflow apparatus. Remove debris immediately upon notice. By: John P. McLean, P.E. file: S i3lg7;r ayre 49 1. 5000 g: EXCISE TAX 5 450-00 11 RECORMNQ THIS COCUVrg FqCSENT D To Til OFFICV Mi E v /k 191-7 I'm PAGE Tax LamtiN�.* ::::Z. ...............I...... .Pirrel IdentifierNo. 13 b 89 %'crffloJb-I., .. . Y­ .... ..........................County On the Day of .............r'J . ................ ]q. ................ by...... ................................... 4 ...................... ... ......... ....................... ................ BRIEF OFSCR THIS IkEb U11 ZVM;11NV0Vf4 tUJU L11'.%_VJ­4 P.O. BOX 4130 E10YALDISLE, fkC 28594 A .4, rrogatea ty Eb&fL AND LN-COL's! P.O. 26X 14130 ENERAMISLE.M. 28594 j31±r FOR INDEX: 1 ACRES QUEENS 'H !CAROLINA 0ENTERAL WAIft TY bEED 1: a Lt.?tL d-A by and tctween. k4pg. 1997 iEK ROAD; GRANTEE GI LOI"f OR Mv WIFE, I PIRATES CONt UC: P )LOUISE hllb3A 601 PELLETIER LOOP ROAD P.O. BOX 1 01 SWANSBORO, NC SWA�NSE O,INC 28584 TIM A ONSLONV- C SEE ATT_A( Onls,mw Cou INN'SLOCK 1109 Wit PAMY; NAME, ADVAE55. AND V AMUMATL, CHARACTER OF ENT! EQ. kRT. gr�. pn Gramor and GraLac, as used h6vin shall include said parties, dieir'hiim Isqu, and a'i A 11 .inch* singular, pirmml, niasmaine, finWre or neuter as roq by , i:j 4HAT thel(jrantdrjbrai.valuable cons de-raior�. paid by the Grantee, the, rco;,iii of id acknat A . [�rd, haLs �and by0w 0 gant, baigain, sell and convey untq!the- t it -alfiiiat;i iktheTq ship of SWANS** imi�r 1 4' T� ry 'onh Carolina, and ilm pitieularly described as follows: Ij D �KMBIT "A" FOR & --.N-TIZI-E LgGAL DESCRIPTION ons urdei that Eamment Lgeerrxemtb�'�W= .by, tranifas any and all ritts and obligati A nd:Astw C'::Mmis and Queens Creek Com' pany as recorded in Book 1007'Pati 493, Rogistry 28-11i-:957 :-"1E1:r FR.'-ri E:rjir=ON-.L:,.CCLN T-7 WIKAH&GE % The property herein�boveldescrilied Was acquired by grantor * instrument recorded in, Back: 1168. daee!k63- Ma SOW COUNTY REGISTRY A map showing the tboy;!described property is recorded in Pl�t Book - 27 age 2013' TO HAVE AND I D HELD Ete doteqa1d l6t or parcel of la0 land 6'ad 11 privilegrea ani . . . . . . I appurtew6es thereto 'I simple. 9 SIMP And the Grantor vo enants with the Grantee, that Grantor is seized of the premises in fen simple, has the right to convey the same i i fee simple, that title is maikceteible and fie and clear of all cncximbra61ces and that Grantor will warrant and de f -.nd:i title against the la '-ful claims of sJil persons whomsoever except for the exceptions hereinafter stated. ',.- Title ;toy tpe irv! )3*e4sQTPxd is.s6bject to the f' Pwai txwliom.' li 11. Tilrs0 is Mide sutj;:�z to Restrktive covenants of =d in the Qaslbw R0210Y. , ,6 2. This cOnM atice 5 ft termia& subject to r6nations, encillErl.brarkes, limitations acid easements of record. W"'ITNESS WfURE-07,The Grantor has hereunto set his liand and seal, or if � orporate, leas caiksed this instrument to I e sl� authorized officers and Its seal to lye hereunto gi'od In its corporate name by Its dul� afffted by authorit r of its Soard of Directori, the day and Fear JIM above written; on Ul lam -Dai execu6od'of tbi I My! Commission COUNtTY0F:Ons Thz &-Tcgoingoctti presented for reqis This th e Ie Lt—h day C i, 6 f D F &NotaqNblic 0 the Davis, Grantor,!Persoftally a jj6stru�cnt.' iWitness my AhnandIN b MOLINA VL Davis aunty acid State afare6k, 6141 ared beibri me this day and ackno%jp' dged the, 1cial seal this he .'clay of Atipst, 1991, Est of Rddftey Rhodes ivare certified to be corrett. This instrarne-it,was n: and recorded in this W-c- in Book: JL 30 8 page: 49 !U t :1997 aq_LJP'clocK-_pJf. M ^.6 AsAlWiirv.l Register V Deeds— 08-14-1597 11:1DAr1 FRO,"! EDMUNDS-0114-IrCa-M TO said ijt&W; road)Fr9m an e the *cg*m RA with the Women, stal.m. beW g the north' = ILqC of S 4t3.52-IW j Jesse J. Fly i al*ng and v*.h s with a coinm'on I tbC rord3j.,ft Hike DR 152, PB 443 Prod�j+ ,deeded .09 We be6c thego, Mudum.by DB stake, a cdmmm CountyRegb4y, S 30029361% 331 said momma= jx D)3 $74, PS 930, S 44*53350NE 2(rj deeded to Alton t as per ur*by C a X"V* b� Pgfty d"m*km �br Aft EXHIBIT] "All 38 at at: iron stake iR the VIPWCM R/W lice Hof WCSR 3509 located :768. . 47'irl a IpUthedY difMidn aloVZtheWgQWCreek Roa mRVfimorw1vqg'RAVmonulocated at - the south" Owme of the R/W jrA=eC6 of 11hica:fNesp, I509 and the Southm "'IiI,0ofNCHwy24;gj==Bj 0A I P-AV YMO Of'NCSR 1509,p 46 '1 8'37"W $0,01, toan On& a6d ; existing iron stake, laid Corner afthe pr4efty deeded to Howardzee m b� Do 663, pg 584, 0- .Wow wife Elaan.c Ri� h 6,0 Wd BramcQjm Courify . sty; 6,61ce ajouv AW W-4 I=PaVY N 4453159"W 250,00 to an 0dating iron stake; thence' f 04.64 v . ; im va"'iron Inpe, said iron pik bcing jhe southwegt to 3�comer orthat. %00=7, NO ir0ft Pipo being in the no'rth= rme Of that property. deeded to! Dd Clara R. FindlcY b� DD 421, Pg 562, OmID: W County Regisiry; the me M1Fk4L'YByte N45v3T14"W487.57'to ne wft ease JFmdLqy propan vd5fing iron pipe, thencic Conthmina e!ty S 42*54'07"W494.04,Io aA,e;d3ft &xmpjPeja:, Oltbsi -Mq*ty dmW to Owdow County R EarnAm MEN and wire NOdred Phillips;as per. ^6 WOAS aru Wftb jL 60tuion exifts iron:located Rhodft by DB in C*mWn Hue with wit that 375,,PS 13, 0jjow Cauaty zion Time of said RhOdeS PfOpwty N 43 aWbollE 91125, to an ocistb* axle, said 60ift em= of aw property deeded to C!'P. Meadows and vjifb Eklml 5 75: PS 422, OrWm Cou*Y Registry; theice X 43*07100*E 977.72, to an km vmer with that property deeded to p Cars0b"s Jmc. DB 1252, P& 752, Onslow topeq WaAg a common line with said Pemion's imc.� property Ir Wi=d)== t6 a ; S 4 7*!4 V52% 453 to an j)dS&S WAGMe inomwmt, ciQmnm corner with that property deeded to Meredith S, Burkhart by )n4w County Registry; tl mcc S 45*06101 -W 99.0-P to a Poilft; thence 92 Wlbc point and plane cif beginning. B�.W8 a poitiou of that property %vi S. by AB 1169 - -P�, d�u . . ,isuyand vontahng 10.89 acres ..oj . .1 We,iik Rawls & Assoc, dated WI 7/917 said =rv*y also being: cmiistmt vAth' miP$':MndA3$oc.datcdC�ciober6,1995 d entitled"MODeePrepareO by dDsA&$* - •• r4r - ' - � -r DIVISION OF WATER QUALITY NORTH CAROLINA STORMWATER MANAGEMENT PERMIT APPLICATION I. GENERAL INFORMATION (Please print clearly or type) 1. Project Name PJRRTGS o'o4' 2. Location, directions to project (include County, Address, State Road) Attach map._qe066- Is yRom Q_u_GEALS_ CA—cg RoRD (WISR l 09) 5iJnNSBOR0 70WN5H1P . ©N6k—l'u, dOL)AW l a6l-IW D G LJ5&V '$ C MA 'Pz,'? ,9 3. Owner's NameeoW' 41-d, Phone ylo-3�3-8o�R 4. Owner's Mailing Address 6o/ &jL r7IER .CaoP RortU City State tub Zip a6-6-8// 5. Nearest Receiving Stream CPR1w96GL BRIWajq Class. SA 6.Projectdescription joy uNIT rawNXousE jCk6,V_r-.dop1WrN7- w/(8) NFw RoPD 191-5o Tv 8c' Bufl,T % leoo 5F &ye /A)ust= 7,-6n;N/5 caj)Rr 0 P,CpV6&,0Nv II. PERMIT INFORMATION 1. Permit N0. (Po hefllled in byDW0 2.Application Date _ 8.t491 Feeencloseda Jg,6'1 3.PermitType:x_New Renewal Modification (existingPermit No.) 4. Project Type: Low Density __X -Detention - Infiltration Redevelop General Alter Offsite 5. Other State/Federal Permits/Approvals Required (Check appropriate blanks) CAMA Major Sedimentation/Erosion Control X 404 Permit III. BUILT UPON AREA (Please see NCAC 2H.1005thru .1007for applicable density limits) Drainage Drainage Breakdown of Impervious Area Basin Basin (Please indicate below the design impervious area) Classification Buildings -7,7. yg4 Existing Built-unon Area Proposed Built -upon Area Total Project Area a53, W8 5F ti9,1, 601 5F l Built -upon Area 6;1 %, IV. STORIMWATER TREATMENT (Describe how the nutajwzll be treated) Streets Parking/SW_ Other r/«'Icfo 5f' 7 A1N15 s c' r1XTi Totals ae:4. IN8 Sr 5TCRMWIUER AU-NQFP T B% DiR,6c4T-D 8y euRB go 6'01: R nu P/g✓gn &/? PS HND & 6dflU t 5WP FS Iry GRHssrl' PR965 TO d'ATOH 13h16I M5 7' PROP I NLers A6 P,5" r1✓F/ y 75W PM—M 1'1Va5?6'At UU vd To 14N oN 51T6 Ii EN-W710N FOND, ATTACIBIEENT A LOW DENSITY AND ALL SUBDIVISION PROJECTS GENERAL SUBAUTTAL REQUIREN F.NTS 1. A completed stormwater permit application. 2. Two sets of plans showing north arrow, scale, revision date, property/project boundaries, lot lines, proposed and existinIt;g contours, drainage areas, mean high water line, wetlands, easements, the 30' minimum vegetated buffer between impervious areas and surface waters, proposed impervious areas, and road cross -sections. 3. Calculations of the built -upon area, For subdivisions, please show the methodology for arriving at the per lot built -upon area. For non -subdivision projects, please break down'the calculatior into buildings, roads, parking, and other (include all impervious areas). 4. Low density projects with curb outlet systems will require: a. Drainage area delineation and swale locations shown on the plans. b. Detail of the swale, showing minimum 5:1 side slope. C. Velocity calculations, indicating a non -erosive flow for the 10 yr storm. d. Inlet and outlet elevations. Maximum longitudinal slope is 5%. e. The type of vegetated cover specified on the plans. f. A flow spreader mechanism located at the swale entrance. g. A signed Operation -and Maintenance Plan. DEED RESTRICTION REQUIRENIENTS The following statements must be included for all low density projects, and for all subdivisions: No more than N.111 square feet of any lot, including that portion of the right-of-way between the edge of pavement and the front lot line, shall be covered by impervious structures, including asphalt, gravel, concrete, brick, stone, slate or similar material, not including wood decking or the water surface of swimming pools. ?his covenant is intended to ensure continued compliance with the stormtivater permit issued by the State of North Carolina. The covenant may not be changed or deleted without the consent of the State. No one may fill in or pipe any roadside or lot -line swale, except as necessary to provide a minimum driveway crossing. For curb outlet system projects, no one may pipe, fill in, or alter any lot line s►vale used to meet North Carolina Stormwater Management Permit requirements. NOTE If lot sizes vary significantly, the owner/developer must provide an attachment listing each lot number, size, and the allowable built -upon area for each lot. V. DEED RESTRICTIONS AND PROTECTIVE COVENANTS Deed restrictions and protective covenants are required to be recorded for all low density projects and all subdivisions prior to the sale of any lot. Please see Attachment A for the specific items that must be recorded for the type of project applied for. By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the items required by the permit, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the covenant cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. VI. OWNER'S CERTIFICATION t I, --J-ct M t_5 1i7. 01/)t7 v�'_S --�r - , "certify that the n;'ormation• il,cluded on this permit (Please print clearly or type) application form is correct, that the project will be constructed in conformance with the approved plans, that the deed restrictions will be recorded with all required permit conditions, and that to the best of my knowledge, the proposed project complies with the requirements of 15A NCAC 2H.1000. I authorize the below named person or firm to submit stormwater plans on my behalf. L.a--J ►KQcx.�. -4� c "P. g'- i Owner/Authoriz Agent Sign ture anle Date VII. AGENT AUTHORIZATION (Please fill in the name of the engineer/seweyor authorized to sidw ie plmu on the owner's behalf.) Person or firm name M14Rka-5 Re RM-6-1-5 ` R5-'4e11RT5 Mailing Address �k46-B PAIN 57R9ET TO, ,bo)6 i/'�Y, City 5Wt9N6BUR0 State Nl; Zip a$5 f3N Phone 9/o --3,7a - /,io8 Please submit application, fee, plans and calculations to the appropriate Regional Office. cc: Applicant/WiRO//Central Files Office use only -;Ur-t : BEACHAH LHB NH&iE riu. . 71V �j3j tidy. =1 ly'j I 4.J7:1ir"1 rLll NCDEM BEACHAM LA130RATORY Itl 640 WILMINGTON HIGHWAY JACKSONVILLE, NORTH CAROLINA 28540 (919 )347--5843 REPORT OF ANALYSES PORTIN CONTRACT SERVICE (DAN) P.O. BOX 4180 EMERALD ISLE, NC 28594- Attn: DAN FORTIN FORTIN CONTRACT SERVICE (Page 1 of 1) SAMPLE LAB No: DATE TIME SAMPLER 40753 05/19/97 1.700 DAN FORTIN CLIEN'P LAB CL- STATION ID NUMBER PPM FORTIN CL- 40753 18.7 DATE: 05/21/97 LABORATORY DIRECTOR DELIVERY TO LAB DATE TIME MATRIX 05/20/97 1530 WW NCDEH #37718 USGS MAP - HUBERT QUADRANGLE SCALE: V= 2000' 1`J �_ /. l I � r� 'a' y \' ly ��1�1 t z 4— NJ �M 2— Avy cl -e- SITE 14 0 cj —35 35 0 x �jkk: —j Y MEMO TD ob BAN Ro IZ ZI N f7F\C,M JOk MCLEAKf _ yam_ SAMPLE: SAKE A-v LEAST Zoo Fr DDWN) LE5UF- LA,�JE- - a c ABC AGGREGATE BASE COURSE MED MEDIAN AC ACRES MH MANHOLE ASPH ASPHALT MJ MECHANICAL JOINT MON MONUMENT B-B BACK OF CURB TO BACK OF CURB MTL METAL BM BENCHMARK MW MONITOR WELL BOC BACK OF CURB BOL BOLLARD N/A NOT APPLICABLE BVC BEGIN VERTICAL CURVE NBL NORTH BOUND.LANF BW BARB WIRE NC NORMAL CROWN NIC NOT IN CONTRACT CcG CURB AND GUTTER NIP NEW IRON PIPE CAN CABLE TELEVISION NTS NOT TO SCALE CB CATCH BASIN CBL CABLE 0/0 ON CENTER CHL CHAIN LINK DO OUTSIDE DIAMETER CI CURB INLET OH OVERHEAD CIP CAST IRON PIPE (L CENTERUNE P/A PARKING AREA CM CONCRETE MONUMENT PC POINT OF CURVATURE CMP CORRUGATED METAL PIPE PCC POINT OF COMPOUND CURVATURE CO CLEAN OUT PED PEDESTAL COM COMMUNICATION PI POINT OF INTERSECTION CONC CONCRETE PINC POINT OF INTERSECTION NO CURVE CONSTR CONSTRUCTION PIV POST INDICATOR VALVE CONTR CONTRACTOR R. PROPERTY LINE CPP CORRUGATED PLASTIC PIPE POC POINT ON CURVE CW CHILLED WATER POS POINT ON SPIRAL POT POINT ON TANGENT DCV DETECTOR CHECK VALVE PP POWER POLE DDCV DOUBLE DETECTOR CHECK VALVE PRC POINT OF REVERSE CURVATURE DI DROP INLET PT POINT OF TANGENCY DIP DUCTILE IRON PIPE PVC POLYVINYL CHLORIDE DRW DRIVEWAY PM POINT OF VERTICAL INTERSECTION DW DOMESTIC WATER PVMT PAVEMENT EBL EAST BOUND LANE R RADIUS EG EXISTING GRADE R/R RAILROAD EIP EXISTING IRON PIPE R/W RIGHT OF WAY ELEC ELECTRIC RCP REINFORCED CONCRETE PIPE ELEV ELEVATION RETW RETAINING WALL EM ELECTRIC METER RPZ REDUCED PRESSURE ZONE z3^ EDGE C; PAVEMENT RT RIGHT ESMT EASEMENT RWM RIGHT OF MONUMENT EVC END VERTICAL CURVE EX. EXISTING SAN SANITARY SB SOIL BORING FES FLARED END SECTION SBL SOUTH BOUND LANE FFE FINISHED FLOOR ELEVATION SIA SIAMESE CONNECTION FG FINISHED GRADE SIG SIGNAL FM FIRE HYDRANT $ SETBACK LINE FL FLOOD LIGHT SIR SIGNAL POLE FNC FENCE STA STATION FOC FACE OF CURB STM STORM SW SIDEWALK GC GENERAL CONTRACTOR GL GAS LINE T TANGENT GM GAS METER TBM TEMPORARY BENCHMARK GRV GRAVEL TCP TERRA COTTA PIPE GTV GATE VALVE TEL TELEPHONE GV GAS VALVE TOC TOP OF CURB GW GUY WIRE TOE TOE OF SLOPE TOP TOP OF SLOPE HC HANDICAP TOW TOP OF WALL HCP HANDICAP PARKING TIP TRUSS PIPE HCR HANDICAP RAMP TRANS TRANSFORMER HOW HEADWALL TYP TYPICAL HP HIGH POINT HT HEIGHT U/G UNDERGROUND UP UTILITY POLE ID INSIDE DIAMETER INV INVERT VC VERTICAL CURVE ISL ISLAND VCP VITRIFIED CLAY PIPE JB JUNCTION BOX WBL WEST BOUND LANE WM WATER METER LF UNEAR FEET WV WATER VALVE LGT LIGHT WW WOVEN WARE LP LIGHT POLE LT LEFT N= ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE APPLICABLE TO THIS PROJECT. EXISTING Nu SITE SYMBOLS DESCRIPTION EXLS71NG DESCRIPTION N MUGU N PROPERTY LINE D ► THRUST BLOCK — — — — 9 AM RIGHT OF WAY ❑ ■ THRUST COLLAR - -- - CENTERLINE ] ] PLUG �' • -- • �' ® TOWN, VILLAGE, CITY LINE p ■ REDUCER -'- -•-•- - ... ............... EASEMENT a SOIL BORING — — — — — SETBACK B MONITOR WELL .. LIMITS OF CONSTRUCTION O COLUMN LINE NUMBER ��-1312 -� �� j3j2 CONTOURS O KEY NOTE NUMBER + 1314.00 314.00 SPOT ELEVATIONS O STORM DRAINAGE BENCH MARK 4 O STRUCTURE NUMBER SOIL BORING NUMBER TREE LINE �.•�.. POND, LAKE, RIVER, STREAM 5❑ SANITARY SEWER STRUCTURE NUMBER RETAINING WALL __---_-___11111=10=09=3111111- STORM DRAIN LINE —X X— --X X— FENCE ---- SS-_=� _SS---- —$S=8$— SANITARY SEWER LINE -- RAILROAD ---- FM--==fM---- FM — FORCE MAIN "--O GUARD RAIL ---- W------- W---- —W W— WATER LINE -.. �_..�._..- _..�._..� _.._ SWALE/DITCH ----0W----H)W---- —IDW-0W— DOMESTIC WATER SILT FENCE ---- FP ------FP---- FIRE PROTECTION LINE CHECK DAM ---- G ------ G ---- —6 0 — GAS LINE INLET PROTECTION --- E ------ E ---- —E—E— ELECTRIC -OVERHEAD 0 a BOLLARD ---UE------- UE---- —iJE-- (J— ELECTRIC-UNDERGR= ■ CATCH BASIN ---- T ------ T --=- —T—T— TELEPHONE -OVERHEAD 0 ® CURB INLET ---- UT ------- UT---- —I1T---UT— TELEPHONE (U/G) 0 Q DROP INLET ---- F------- F ---- — F F — FUEL LINE Q MANHOLE —UO----- UQ— UNDERGROUND CABLE QQ {� JUNCTION BOX mmom EXISTING BUILDING TO BE DEMOLISHED D FLARED END SECTION AREA TO BE DISTURBEI CLEAN OUT MODIFIED OR REMOVED FIRE HYDRANT EXISTING TREES �c+� TO BE REMOVED O • BLOW -OFF 0 VALVE 0 ELECTRIC METER © , GAS METER ❑W ®� WATER METER © ® CABLE PEDESTAL TC� ® TELEPHONE PEDESTAL ® r2l TRANSFORMER 7Q( LIGHT POLE WALL LIGHT BOLLARD LIGHT FLOOD LIGHT 1�------- J '—O UTILITY POLE W/GUY WARE ❑o CONCRETE MONUMENT `Q RIW MONUMENT WO WELL SIGNS QE TREES