HomeMy WebLinkAboutGum Branch Rd (U-4906), Jacksonville NC (Revision-1)DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC CONTACTS SITE INDEX SCOPE OF WORK: DIRECTIONAL BORE (3) 1-1/4" HDPE CONDUITS 2306' AND PLACE (3) NEW HANDHOLES. pULL 2706' OF NEW 96CT FOC. CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 1 15 Know what's below. before you dig.Call R SEGRA ENGINEER MIKE WORNOM CELL -- 803-609-1860 MIKE.WORNOM@SEGRA.COM TPRC BROADBAND SPECIALIST JUSTIN CALLOWAY (336) 285-7497 justin@tprcbroadband.com 01 - COVER SHEET/SITE LOCATION 02 - CONTACT LIST AND REQUIRED PERMITS 03 - LEGEND 04 - GENERAL NOTES 05 - OSP PROJECT SHEET 06 - OSP PROJECT SHEET 07 - OSP PROJECT SHEET 08 - OSP PROJECT SHEET 09 - OSP PROJECT SHEET 10 - OSP PROJECT SHEET 11 - UNDERGROUND TYPICALS 12 - UNDERGROUND TYPICALS 13 - BONDING & GROUNDING TYPICALS 14 - DIRECTIONAL BORE DETAIL TYPICALS 15 - RAKE OFF TOTALS PERMITS REQUIRED 1 - NCDOT 16.1 ADDRESS: GUM BRANCH RD, JACKSONVILLE NC (ONSLOW COUNTY) PROJECT NAME: U-4906 SERVICE ORDER: 2003-14 FIBER ORDER ID: EBS: SITE LOCATION SHEET 5 SHEET 6 SHEET 7 SHEET 8 SHEET 9 SHEET 10 DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC OUTSIDE PLANT ENGINEERING: MANAGER: PROJECT MANAGER: PROJECT ENGINEER: INSPECTOR: OUTSIDE PLANT CONSTRUCTION CONTRACTOR: PROJECT SUPERVISOR: PROJECT CONST. SUPERVISOR: MANAGER: CITY GOVERNMENT: COUNTY GOVERNMENT: STATE OF NORTH CAROLINA GOVERNMENT: RIGHT OF WAY RAILROADS: NORTH CAROLINA ONE CALL CALL BEFORE YOU DIG 811 OR 1-800-632-4949 UTILITIES: ELECTRIC: GAS: CABLE TV: TELEPHONE: WATER / SEWER: STATE OF NORTH CAROLINA DEPARTMENT OF PUBLIC SAFETY: STATE HIGHWAY PATROL: CITY POLICE: COUNTY POLICE: ONSLOW COUNTY JACKSONVILLE PHONE: PHONE: PHONE: NAME: NAME: PHONE: PHONE: PHONE:NAME: PHONE: PHONE: PHONE: ADDRESS: ADDRESS: ADDRESS: REQUIRED PERMITS: SITE DETAILS: NAME: E-MAIL: 1) 2) 3) CALL PROPERTY OWNERS 24 HOURS IN ADVANCE PRIVATE EASEMENTS / RIGHT OF ENTRY: NAME: ADDRESS: PHONE: PHONE: E-MAIL: NAME: ADDRESS: PHONE: E-MAIL: SEGRA PERMITTING CONTACT: NAME: ADDRESS: PHONE: E-MAIL: NAME: ADDRESS: PHONE: E-MAIL: SEGRA EMERGENCY CONTACT NUMBERS: NOC: CUSTOMER CARE: E-MAIL:noc@segra.com 877-411-6930 E-MAIL: 833-467-3472 customercare@segra.com 910-455-3113 910-455-4000 910-347-1751 910-467-0505 910-347-4717 910-938-5333 336-285-7497 MIKE WORNOM JUSTIN CALLOWAY TREVOR CARROLL 305 WILMINGTON HWY, JACKSONVILLE, NC 200 MARINE BLVD JACKSONVILLE, NC 717 COURT ST JACKSONVILLE, NC 803-609-1860CELL: NCDOT 16.1 CONTACT LIST AND REQUIRED PERMITS CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 2 15 Know what's below. before you dig.Call R DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC UTILITY POLE - EXISTING RISER TELEPHONE POWER VAULT POLE ANCHOR/DOWN GUY - EXISTING POLE ANCHOR/DOWN GUY - PROPOSED STREET LIGHT MISC. UTILITY MANHOLE - PROPOSED POLE - PROPOSED GROUND/BOND TREE FIRE HYDRANT CULVERT WING WALL BRIDGE HANDHOLE - EXISTING HANDHOLE - PROPOSED MANHOLE - EXISTING VAULT - PROPOSED PULLBOX - EXISTING VAULT/BUILDING STORAGE - EXISTING VAULT/BUILDING STORAGE - PROPOSED AERIAL STORAGE - EXISTING AERIAL STORAGE - PROPOSED SPLICE POINT - PROPOSED SPLICE POINT - EXISTING PULBOX - PROPOSED VAULT - EXISTING STRAND - PROPOSED AERIAL FIBER - EXISTING STRAND - EXISTING INNERDUCT - EXISTING UG FIBER - EXISTING CONDUIT - EXISTING UG FIBER - PROPOSED AERIAL FIBER - PROPOSED CONDUIT - PROPOSED INNERDUCT - PROPOSED GAS WATER TELEPHONE ELECTRIC SANITARY SEWER (SEW) STORM DRAIN FENCE CABLE TV STEAM OIL UNKNOWN UTILITY LINETYPES PVC MH STA. RGS RIGID GALVANIZED STEEL CONDUIT POLY VINYL CHLORIDE STATION ASW SYMBOL BIP CSW MP HDPE O/S EOP EOTW JB HH FOC ASPHALT SIDEWALK BOS FIBER OPTIC CABLE HANDHOLE JUNCTION BOX MILE POST HIGH DENSITY POLYETHYLENE MANHOLE OFFSET CONCRETE SIDEWALK EDGE OF PAVEMENT EDGE OF TRAVEL WAY BACK OF SIDEWALK BLACK IRON PIPE DESCRIPTION ROW RIGHT OF WAY CATCH BASIN/INLET TERMINATION - EXISTING RIGHT OF WAY EDGE OF PAVEMENT TERMINATION - PROPOSED BUILDING CALLOUT - PROPOSED MANUFACTURER NAME FDP NAME SIZE LOCATION FDP NAME SIZE LOCATION POLE ATTACHMENT CALLOUT - EXISTING POLE ATTACHMENT CALLOUT - PROPOSED POLE NO N/A UTILITY1 0'-0" POLE NO N/A UTILITY1 0'-0" USE DYNAMIC PULL DOWN TO SELECT FROM 1 TO 6 ATTACHMENTS USE DYNAMIC PULL DOWN TO SELECT FROM 1 TO 6 ATTACHMENTS V VAULT- VAULT SEGRA V VAULT- VAULT SEGRA ID SEGRA ID OWNER 0' 0' 0' 0' CABLE SPAN CALLOUT - EXISTING CABLE SPAN CALLOUT - PROPOSED CONDUIT CALLOUT - EXISTING CONDUIT CALLOUT - PROPOSED STRAND CALLOUT - EXISTING STRAND CALLOUT - PROPOSED FOR USE ON PAPER SPACE (SHOWN AT 50X) FOR USE ON PAPER SPACE (SHOWN AT 50X) FOR USE ON PAPER SPACE (SHOWN AT 50X) FOR USE ON PAPER SPACE (SHOWN AT 50X) FOR USE ON PAPER SPACE (SHOWN AT 50X) FOR USE ON PAPER SPACE (SHOWN AT 50X) SEQUENTIAL CALLOUT SEQUENTIAL IN TAIL CALLOUT 1 1 1 1 1 1 SEQUENTIAL TAIL OUT CALLOUT WITH OR WITHOUT INNER DUCT INFO WITH OR WITHOUT INNER DUCT INFO PROPOSED DOWN GUY ON EXISTING ANCHOR HH HH- HANDHOLE SEGRA HH HH- HANDHOLE SEGRA MH- MANHOLE SEGRA MH- MANHOLE SEGRA PB PB- PULLBOX SEGRA PB PB- PULLBOX SEGRA BUILDING NAME STREET MANUFACTURER NAME SIDEWALK 0 0CT 0 0CT 0 0CT LEGEND CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 3 15 Know what's below. before you dig.Call R DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC GENERAL NOTES ·CONTRACTOR MUST OBTAIN LOCATES PRIOR TO DISTURBING THE GROUND. ·CONTRACTOR MUST HAVE A COPY OF THE APPROVED PERMIT FROM THE APPROPRIATE AGENCY ON THE JOBSITE AT ALL TIMES. ·ALL CABLE WILL BE PLACED AT STANDARD MINIMUM DEPTH. (SEGRA STANDARD IS 48'' DEEP UNLESS OTHERWISE DIRECTED BY A SEGRA REPRESENTATIVE.) ·ANY LANDSCAPING WILL BE REPLACED TO EQUAL OR BETTER THAN THAT WHICH EXISTED PRIOR TO WORK. ·PROJECT SITE WILL BE PROPERLY SECURED PRIOR TO THE END OF EACH DAY. ·ALL WORK IS TO BE IN ACCORDANCE WITH ALL AUTHORITIES HAVING JURISDICTION IN THE WORK ZONE. ·CONTRACTORS ARE ADVISED TO CONTACT SEGRA FOR ANY ADDITIONAL INFORMATION OR CLARIFICATION CONCERNING SCOPE OF WORK OR THE REQUIREMENTS NECESSARY FOR PROJECT COMPLETION. ·CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL DIMENSIONS, QUANTITIES AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. IF A SIGNIFICANT CHANGE TO THE RUNNING LINE IS NEEDED, PLEASE CONTACT YOUR SEGRA REPRESENTATIVE BEFORE PROCEEDING. ·BEFORE CONSTRUCTION BEGINS, CONTRACTOR SHALL TAKE APPROPRIATE PRECAUTIONS TO AVOID ANY POTENTIAL OBSTRUCTIONS PRIOR TO PROCEEDING WITH WORK. ·NO CONSTRUCTION ON PRIVATE PROPERTY WILL COMMENCE UNTIL APPROVAL IS GIVEN BY THE APPROPRIATE SEGRA EMPLOYEE. ·CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL THEY HAVE RECEIVED A PURCHASE ORDER AND HAVE BEEN DIRECTED TO DO SO BY AN AUTHORIZED SEGRA REPRESENTATIVE. ·CONTRACTOR SHALL NOT EXCEED THE PURCHASE ORDER VALUE WITHOUT AUTHORIZATION IN WRITING FROM THE APPROPRIATE SEGRA REPRESENTATIVE. ·AS-BUILTS WILL BE REQUIRED FOR EACH PROJECT INCLUDING CABLE FOOTAGE SEQUENTIALS AT EVERY ACCESS POINT, SLACK LOOP, SPLICE LOCATION, POLE AND TERMINATION POINT. CONTRACTOR SHOULD ALSO PROVIDE NOTES OF ALL CHANGES IN DEPTHS, RUNNING LINES, WH/HH LOCATIONS, AND ANY OTHER APPLICABLE NOTES TO DEPICT THE WORK THAT TOOK PLACE. NOTE: ALL MAJOR CHANGES NEED TO BE PRE-APPROVED BY AN AUTHORIZED SEGRA EMPLOYEE PRIOR TO STARTING THE WORK. SITE CONDITIONS ·THE ACTUAL LOCATION OF EXISTING CONDUIT AND CABLES MAY VARY FROM THE LOCATION SHOWN. REPAIR OF ANY DAMAGED CONDUIT CONTAINING CABLE SHALL BE MADE BY USE OF PVC SPLIT DUCT. THE CONTRACTOR SHALL ENCLOSE THE EXISTING CABLES IN PVC. ·THE LOCATIONS OF EXISTING UTILITIES SHOWN IN THIS PLAN ARE APPROXIMATE. WHEN WORK IS TO BE CONDUCTED IN THE VICINITY OF KNOWN UTILITIES, THEIR ACTUAL LOCATION MUST BE FIELD VERIFIED TO AVOID CONFLICTS IR DAMAGE TO THOSE UTILITIES. VARIATION IN LOCATION BETWEEN "RECORDED POSITIONS" AND ACTUAL POSITIONS SHOULD BE ANTICIPATED. ·IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES. BURIED UTILITIES MAY EXIST IN THE AREA IN ADDITION TO THOSE SHOWN ON THE PLAN. THE CONTRACTOR SHALL CONTACT PROPERTY OWNERS WHEN WORKING WITHIN PRIVATE EASMENTS FOR LOCATION OF UNDERGROUND TANKS, PIPELINES, DRAIN TILES, OR OTHER BURIED IMPROVEMENTS. THE CONTRACTOR SHALL ALSO NOTIFY THE UTILITY NOTIFICATION CENTER PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITIES. ·THE CONTRACTOR MUST ASSUME ALL BURIED UTILITIES ENCOUNTERED ARE ALIVE AND ACTIVE UNLESS SPECIFICALLY INSTRUCTED OTHERWISE BY OWNERS OR OPERATORS OF SAID UTILITIES. ·DAMAGE TO SUB-SURFACE STRUCTURES IS THE SOLE RESPONSIBILITY OF THE PLACING CONTRACTOR. ·THE CONTRACTOR SHALL PROTECT THE EXISTING TRAFFIC CONTROL LOOPS. IF EXISTING TRAFFIC CONTROL LOOPS ARE DAMAGED DURING CONSTRUCTION, THE ENTIRE LOOPWIRE FROM TERMINAL TO TERMINAL SHALL BE REPLACED IN ACCORDANCE WITH GOVERNING AGENCY STANDARDS AND REGULATIONS AT CONTRACTOR'S EXPENSE. ·REMOVAL OF EXISTING ASPHALT PAVEMENT, CONCRETE CURBS, AND CONCRETE SIDEWALKS WILL BE "NEAT LINE" WITH SAW OR PAVEMENT CUTTER, PER REQUIREMENTS AND SPECIFICATIONS OF THE AGENCY OR DEPARTMENT RESPONSIBLE FOR EACH LOCATION. IF CONCRETE PAVEMENT IS ENCOUNTERED WHILE EXCAVATING CONDUIT TRENCHES, THE CONCRETE REMOVAL WILL BE "NEAT LINE" WITH A PAVEMENT SAW. ·IF CONCRETE CURB RETURNS AND/OR SIDEWALKS ARE REPLACED DUE TO CONDUIT OR MANHOLE INSTALLATION, THE CONTRACTOR SHALL PLACE APPROVED HANDICAPPED SIDEWALK AND CURB ACCESS RAMPS IN CONFORMANCE WITH STATE OF JURISDICTION STATUTES. ·ALL MATERIALS NECESSARY FOR THE REPAIR OF STREETS, CURBS, SIDEWALKS, SANITARY SEWERS, STORM SEWERS, AND PUBLIC SERVICE UTILITIES, AND THE INSTALLATION OF SUCH MATERIALS SHALL BE IN CONFORMANCE WITH THE REQUIREMENTS AND SPECIFICATIONS OF THE AGENCY OR DEPARTMENT RESPONSIBLE FOR THE OPERATION AND MAINTENANCE OF THE REPAIRED FACILITY. ·ALL WORK SHALL CONFORM TO THE SPECIFICATIONS OF THE JURISDICTIONAL PERMIT AGENCY. ·ALL OPEN TRENCH WILL BE CLEARLY MARKED WITH BARRICADES OR CONES. STEEL PLATES OR OTHER TYPES OF BRIDGING SHALL BE PROVIDED TO COVER OPEN TRENCH IN THE TRAVEL PORTION OF THE STREETS. THESE PLATES OR BRIDGING SHALL BE ADEQUATE TO SUPPORT THE NORMAL VEHICLE LOADS ANTICIPATED IN THIS AREA AND SHALL BE IN PLACE DURING ALL NON-WORKING AREAS. ·ALL SURFACES TO BE RESTORED TO ORIGINAL CONDITION, AND BACKFILL TO BE COMPACTED AS SPECIFIED. TRENCH EXCAVATION IN SURFACES WHICH INCLUDE CONCRETE TREATED BASE SHALL FOLLOW LOCAL AREA SPECIFICATIONS. HAZARDOUS MATERIALS ·THE CONTRACTOR SHALL NOTIFY THE JURISDICTIONAL PERMIT AGENCY IMMEDIATELY IF ANY MATERIALS ARE ENCOUNTERED THAT ARE CONSIDERED HAZARDOUS BY THE EPA, DEQ, OR OSHA. IF POTENTIALLY HAZARDOUS MATERIALS ARE ENCOUNTERED THE CONTRACTOR SHALL SECURE THE SITE AND PREVENT THE ACCIDENTAL EXPOSURE BY THE PUBLIC OR THE CONTRACTOR'S PERSONNEL. ·THE CONTRACTOR MAY EXCAVATE UP TO, BUT SHALL NOT DISTURB KNOWN HAZARDOUS MATERIALS SUCH AS ASBESTOS, OILS, ACID, ETC. THE REMOVAL OF ALL HAZARDOUS MATERIALS MUST BE DONE BY AN APPROVED OR CERTIFIED HAZARDOUS MATERIALS CONTRACTOR LICENSED BY THE STATE OF JURISDICTION. ·A COPY OF ALL CORRESPONDENCE PERTINENT TO THE REMOVAL OF HAZARDOUS MATERIALS SHALL BE TRANSMITTED TO OWNER AND A COPY SHALL BE AVAILABLE AT THE PROJECT OFFICE AND THE JOB SITE. AERIAL NOTES ·AERIAL CONSTRUCTION TO BE PERFORMED TO INDUSTRY ACCEPTABLE STANDARDS. ·ALL HEIGHTS OF CABLE PLACEMENT WILL BE RECORDED AT TIME OF CONSTRUCTION. DOCUMENT ALL POINTS OF ATTACHMENT. ·6.6M STRAND WILL BE USED WITH STANDARD 5/8 HARDWARE. ·ALL EXTENSION ARMS TO BE PLACED WILL BE EPOXY ARMS UNLESS OTHERWISE NOTED OR APPROVED BY THE INSPECTOR. ·BOND STRAND TO POWER MGN WHERE APPLICABLE. ANCHORS TO BE USED WILL BE 3/4 SCREW IN TYPE. ·ALL STRAPS WILL BE PLACED 4" BEFORE AND AFTER EVERY SUPPORTING CLAMP AT A MINIMUM OF 21" APART. ·P.O.A. = POINT OF ATTACHMENT. ·ADD MISSING GROUNDS. ·REPAIR/REPLACE EXISTING LASHING WIRE IF DAMAGED. CONSTRUCTION STAKING ·IN AREAS WHERE THE CONDUIT ALIGNMENT IS NOT CLEARLY DEFINED BY CURB LINES, FENCE LINES, OR OTHER EVIDENCE OF THE RIGHT-OF-WAY, THE ENGINEER WILL PROVIDE CENTERLINE STAKES OR PAINT MARKS WHERE REQUIRED TO MAKE THE PROPOSED CONDUIT ALIGNMENT EVIDENT. ·MANHOLE CENTERS WILL BE FIELD STAKED BY THE ENGINEER WHEN REQUESTED WITH OFFSET STAKES AT RIGHT ANGLES (90°) TO THE CONDUIT ALIGNMENT. ·CLOSURES IDENTIFIED IN THE PLANS SHALL BE LOCATED BY THE CONTRACTOR. DEVIATION FROM PLAN LAYOUT SHALL BE APPROVED BY THE ENGINEER PRIOR TO CONDUIT AND/OR CLOSURE INSTALLATION. ·IF ADDITIONAL, FIELD STAKING OR LOCATION OF CONDUITS, MANHOLES, PROPERTY LINES, ETC., BECOMES NECESSARY, THE CONTRACTOR IS TO NOTIFY THE INSPECTOR OR THE ENGINEER TWO WORKING DAYS PRIOR TO BEGINNING THE WORK. PERMITS - FRANCHISES - EASEMENTS ·PHYSICAL WORK SHALL NOT BE STARTED UNTIL THE GOVERNING AGENCY INSPECTOR AND THE CONTRACTOR ARE IN POSSESSION OF AND HAVE CAREFULLY REVIEWED AND FULLY UNDERSTAND ALL CONDITIONS AND SPECIFICATIONS SET FORTH IN THE REQUIRED PERMITS, FRANCHISES, AND/OR EASEMENTS. ·PLACING FOREMAN TO HAVE A COPY OF THE PERMITS/EASEMENTS ON SITE AT ALL TIMES. ·ANY CONFLICT BETWEEN WORK PRINT SPECIFICATIONS AND SPECIFICATIONS SET FORTH UNDER RELATED PERMITS, FRANCHISES, AND/OR EASEMENTS MUST BE CLEARED BY PROPER COMPANY AUTHORITY BEFORE PROGRESSING WITH WORK INVOLVED. TRAFFIC CONTROL ·THIS PROJECT WILL INVOLVE WORKING ALONG A MAJOR ARTERIAL ROAD AND HEAVY TRAFFIC VOLUME SHOULD BE ANTICIPATED. ·UNIFORM TRAFFIC FLOW SHALL BE MAINTAINED AT ALL TIMES. ONLY EQUIPMENT AND MATERIALS NECESSARY FOR IMMEDIATELY SCHEDULED OR IN PROGRESS WORK WILL BE MAINTAINED IN THE WORK AREA. ALL OTHER EQUIPMENT AND MATERIALS WILL BE "STORED OR STOCKPILED" IN SUCH A MANNER AS TO ELIMINATE HAZARDOUS CONDITIONS FOR TRAFFIC OR PEDESTRIANS DURING NON-WORKING OR SHUT DOWN PERIODS. ·TRAFFIC WARNING DEVICES AND SIGNS SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS (U.S. GOVERNMENT PRINTING OFFICE) AND TO THE STATE HIGHWAY DIVISION STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION. HIGH LEVEL WARNING TYPE DEVICES ARE TO BE USED AT ALL TIMES AND SPECIAL WARNING DEVICES MAY BE STIPULATED BY THE JURISDICTIONAL PERMIT AGENCY AT ANY TIME THE USE WILL ADD TO THE SAFETY AND PROTECTION OF TRAFFIC OR PEDESTRIANS IN THE CONSTRUCTION AREA. ·ALL CONDUIT TRENCHING IN PAVED AREAS SHALL BE BACKFILLED WITH CRUSHED GRAVEL OR COMPLETELY COVERED AT THE COMPLETION OF EACH WORKING DAY. ANY BACKFILLED TRENCH SHALL BE CAPPED WITH A MINIMUM LAYER OF ASPHALTIC CONCRETE COLD PATCH AT THE END OF EACH WORKING DAY. ·THE CONTRACTOR SHALL MARK THE CONDUIT TRENCH AND DEFINE HIS CONSTRUCTION AREA CLEARLY WITH BARRICADES, CONES, AND/OR OTHER VISIBLE METHODS THAT ALERT THE PUBLIC OF THE CONSTRUCTION ACTIVITY. ·A TRAFFIC CONTROL PLAN SHALL BE PREPARED BY THE CONTRACTOR AS REQUIRED AND SUBMITTED TO EACH PERMITTING AGENCY REQUESTING SUCH PLAN FOR REVIEW AND APPROVAL OR REVISION PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY FOR THIS PROJECT. THE APPROVED PLAN SHALL BE SUBMITTED TO THE AGENCY AND A COPY OF THE PLAN SHALL BE KEPT AT THE CONSTRUCTION SITE AND MUST BE READILY AVAILABLE FOR REVIEW BY THE AGENCY REPRESENTATIVES. SPECIAL UTILITY CLEARANCES ·ALL WORK CONDUCTED ADJACENT TO WATER MAINS SHALL CONFORM TO THE FOLLOWING CONDITIONS: A.WHEREVER POSSIBLE CONDUIT SHALL MAINTAIN A HORIZONTAL SEPARATION OF 3.0 FEET, MEASURED SURFACE TO SURFACE (OUTSIDE EDGE TO OUTSIDE EDGE), FROM PARALLEL WATER MAINS. B.WHEREVER POSSIBLE, CONDUIT SHALL PASS UNDER EXISTING WATER MAINS AND MUST MAINTAIN 12" VERTICAL CLEAR SEPARATION. CONDUITS PASSING OVER WATER MAINS MUST ALSO MAINTAIN THE 12" VERTICAL SEPARATION. C.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ESTABLISHING AND MAINTAINING THIS REQUIRED VERTICAL SEPARATION BY EITHER EXPOSING THE WATER MAIN EVERY 100 FEET IN THOSE AREAS WHERE HORIZONTAL SEPARATION IS LESS THAN 3.0 FEET OR BY UTILIZING THE DEPTHS OF ADJACENT WATER VALVES. IF THE CONTRACTOR UTILIZES THE ADJACENT WATER TO DETERMINE WATER MAIN DEPTH, HE SHALL CONTACT THE AGENCY AT EACH SUCH LOCATION AND THE AGENCY WILL DETERMINE THE NECESSARY DEPTH OF THE TOP OF THE CONDUIT AT THAT POINT. D.THE VERTICAL AND HORIZONTAL SEPARATION SHALL BE MAINTAINED AT ALL TIMES UNLESS SPECIFICALLY REVISED BY AGREEMENT BETWEEN THE JURISDICTIONAL PERMIT AGENCY AND THE AGENCY ANY SPECIFIC DEVIATION IN VERTICAL AND HORIZONTAL SEPARATION FROM THOSE DESCRIBED SHALL BE REPORTED TO THE OWNER BY THE CONTRACTOR. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING VERTICAL AND HORIZONTAL SEPARATION AT ALL TIMES AND SHALL BE RESPONSIBLE FOR ANY AND ALL ENCROACHMENTS. E.CLEARANCES TO STORM SEWERS AND SANITARY SEWERS SHALL BE EXACTLY THE SAME AS THOSE TO WATER MAINS. STRUCTURE PROTECTION ·MANHOLES AND CONDUIT TO BE PLACED ADJACENT TO EXISTING STRUCTURES SUCH AS BRIDGE BRIDGE FOOTINGS/PIERS, BUILDING FOUNDATIONS, WALLS, POWER AND TELEPHONE POLES, AND OTHER UTILITIES SHALL MAINTAIN A MINIMUM CLEARANCE AS SHOWN. THE CONTRACTOR SHALL NOT UNDERMINE ANY ADJACENT STRUCTURE WITHOUT SPECIFIC WRITTEN PERMISSION FROM THE OWNER/OPERATOR OF SUCH STRUCTURE. ·SHORING USED AS FOUNDATION SUPPORT SHALL BE DESIGNED SPECIFICALLY FOR BOTH THE LIVE AND DEAD LOADS OF THE STRUCTURE, OR IF ONLY THE DEAD LOAD IS USED FOR DESIGN, THE CONTRACTOR SHALL PROVIDE A DETAILED LAYOUT AND PLAN OF THE METHOD OF ESTABLISHING AND MAINTAINING THE DESIGN LOAD CONDITIONS (I.E., ROAD DETOURS, TIEBACKS, ETC.) ·SEE UTILITY CLEARANCE SECTION NOTES FOR CLEARANCE CRITERIA TO PARALLEL OR CROSS UTILITIES. ·EXISTING UTILITIES EXPOSED DURING EXCAVATION SHALL BE 100% SUPPORTED BY EITHER TRENCH BRIDGING AND SUSPENSION OR BY THE USE OF LONGITUDINAL TRAYS OR PLATFORMS VERTICALLY SUPPORTED BY ADJUSTABLE BUILDING JACKS. ·EXISTING SPLICE CASES AND CABLES SHALL BE SUPPORTED BY SUSPENSION FROM A CROSSING BEAM. SUPPORTS SHALL BE PLACED AT A MAXIMUM SPACING OF 4.0 FEET AND SHALL CONSIST OF A CANVAS SLING WITH NYLON BELTING OR ROPE. ALL CABLE SUPPORTS SHALL BE PLACED IN A MANNER THAN PREVENTS KINKS OR OTHER DAMAGE TO THE CABLE SHEATH. ·AN ACCEPTABLE ALTERNATIVE TO CABLE SLINGS WOULD BE THE UTILIZATION OF A WIDE FLANGE "I" BEAM OR CHANNEL AS A "CABLE TRAY" WITH THE CABLES/CASES BANDED IN PLACE. SHORING ·THE CONTRACTOR SHALL PROVIDE SHORING FOR CONDUIT TRENCH EXCAVATION 42" OR MORE IN DEPTH AS MEASURED FROM THE HIGH SIDE OF THE TRENCH AND FOR ALL MANHOLE EXCAVATION. ·MANHOLE SHORING SHALL BE TIGHT-SHEETED. ·ALL SHORING SHALL CONFORM TO THE STANDARDS AND SPECIFICATIONS OF LOCAL COUNTY AND THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA). ·SHORING SHALL BE DESIGNED TO MEET H-20 HIGHWAY LOADING. ·THE CONTRACTOR SHALL PROVIDE ALL SHORING AND DESIGN CALCULATIONS TO THE PERMIT ISSUING AGENCY PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY. GENERAL NOTES CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 4 15 Know what's below. before you dig.Call R DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC H H H H - 1 P L A C E L O C A T E M A R K E R P O S T H H H H - 2 W / G R A V E L G R O U N D R O D M A R K E R P O S T B P - 1 B P 1 0 0 ' 5 0 ' RAMSEY RD (SR-132 4 ) G U M B R A N C H R D ( S R - 1 3 0 8 ) ( 1 7 5 ' ) (62') ( 3 9 5 ' ) 0 0 + 0 0 0 1 + 7 5 0 2 + 3 7 75' 36'21' 5' MATCH TO SHEET 6 0 096ct 0 096ct ABANDON FIBER AFTER CUT OVER 1 2 3 45 6 BORE AT A DEPTH OF 10' 5'7' # CONSTRUCTION NOTES Page Rake Off Unit Code & Description Units Estimated Quantity Actual Quantity CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 5 15 Know what's below. before you dig.Call R SCALE IS FOR REFERENCE PURPOSES ONLY. THE CABLE CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE APPROPRIATE PERMITTING MUNICIPALITY PRIOR TO BEGINNING CONSTRUCTION, IN ORDER TO VERIFY THAT THE CABLE IS BEING PLACED WITHIN THEIR RIGHT-OF-WAY. 2 3 1 5 4 6 DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC B P - 2 B P G U M B R A N C H R D ( S R - 1 3 0 8 ) ( 3 9 0 ' ) 0 6 + 3 2 75' 36' 22' 4' MATCH TO SHEET 5 MATCH TO SHEET 7 ABANDON FIBER AFTER CUT OVER 1 2 BORE AT A DEPTH OF 10' # CONSTRUCTION NOTES Page Rake Off Unit Code & Description Units Estimated Quantity Actual Quantity CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 6 15 Know what's below. before you dig.Call R SCALE IS FOR REFERENCE PURPOSES ONLY. THE CABLE CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE APPROPRIATE PERMITTING MUNICIPALITY PRIOR TO BEGINNING CONSTRUCTION, IN ORDER TO VERIFY THAT THE CABLE IS BEING PLACED WITHIN THEIR RIGHT-OF-WAY. 1 2 DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC B P - 3 B P H H H H - 3 W / G R A V E L G R O U N D R O D M A R K E R P O S T 1 0 0 ' BEAGLE LN BATTIN G C A G E T R L ( 1 4 0 ' ) 1 0 + 2 2 1 1 + 6 2 60' 75' 36' 22' 5' MATCH TO SHEET 6 MATCH TO SHEET 8 0 096ct ABANDON FIBER AFTER CUT OVER 1 2 3 BORE AT A DEPTH OF 10' 2' 10' # CONSTRUCTION NOTES Page Rake Off Unit Code & Description Units Estimated Quantity Actual Quantity CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 7 15 Know what's below. before you dig.Call R SCALE IS FOR REFERENCE PURPOSES ONLY. THE CABLE CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE APPROPRIATE PERMITTING MUNICIPALITY PRIOR TO BEGINNING CONSTRUCTION, IN ORDER TO VERIFY THAT THE CABLE IS BEING PLACED WITHIN THEIR RIGHT-OF-WAY. 3 1 2 DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC B P - 4 B P G U M B R A N C H R D ( S R - 1 3 0 8 ) ( 3 9 0 ' ) 1 5 + 5 2 60'8' 2' 36' 10' 2' MATCH TO SHEET 7 MATCH TO SHEET 9 ABANDON FIBER AFTER CUT OVER 1 2 BORE AT A DEPTH OF 10' 3' 8' # CONSTRUCTION NOTES Page Rake Off Unit Code & Description Units Estimated Quantity Actual Quantity CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 8 15 Know what's below. before you dig.Call R SCALE IS FOR REFERENCE PURPOSES ONLY. THE CABLE CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE APPROPRIATE PERMITTING MUNICIPALITY PRIOR TO BEGINNING CONSTRUCTION, IN ORDER TO VERIFY THAT THE CABLE IS BEING PLACED WITHIN THEIR RIGHT-OF-WAY. 1 2 DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC G U M B R A N C H R D ( S R - 1 3 0 8 ) BAMBOO LN EDGEWOOD D R ( 4 0 0 ' ) B P - 5 B P ( 2 7 5 ' ) 1 9 + 5 2 60' 37' 7' 4' MATCH TO SHEET 8 MATCH TO SHEET 10 ABANDON FIBER AFTER CUT OVER 1 2 3 BORE AT A DEPTH OF 10' # CONSTRUCTION NOTES Page Rake Off Unit Code & Description Units Estimated Quantity Actual Quantity CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 9 15 Know what's below. before you dig.Call R SCALE IS FOR REFERENCE PURPOSES ONLY. THE CABLE CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE APPROPRIATE PERMITTING MUNICIPALITY PRIOR TO BEGINNING CONSTRUCTION, IN ORDER TO VERIFY THAT THE CABLE IS BEING PLACED WITHIN THEIR RIGHT-OF-WAY. 2 1 3 DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC H H H H - 5 P L A C E L O C A T E M A R K E R P O S T H H H H - 4 W / G R A V E L G R O U N D R O D M A R K E R P O S T B P - 6 B P 5 0 ' 1 0 0 ' (52' ) ( 2 7 ' ) 2 2 + 2 7 2 2 + 7 9 2 3 + 0 6 65' 37' 7' 5' 8'5' MATCH TO SHEET 9 0 096ct 0 096ct ABANDON FIBER AFTER CUT OVER DIRECTIONAL BORE 10' BELOW CREEK BED 1 2 3 4 5 BORE AT A DEPTH OF 10' # CONSTRUCTION NOTES Page Rake Off Unit Code & Description Units Estimated Quantity Actual Quantity CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 10 15 Know what's below. before you dig.Call R SCALE IS FOR REFERENCE PURPOSES ONLY. THE CABLE CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE APPROPRIATE PERMITTING MUNICIPALITY PRIOR TO BEGINNING CONSTRUCTION, IN ORDER TO VERIFY THAT THE CABLE IS BEING PLACED WITHIN THEIR RIGHT-OF-WAY. 3 5 1 2 4 DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC TYPICALS DIMENSIONS LENGTH WIDTH DEPTH OUTSIDE 51 3/4"34 3/4"35 3/4" INSIDE 46 1/2"28 3/4"32 3/4" EMBEDDED RACKING (2 EACH SIDE) ANTI-SLIP TREAD PATTERN 35 - 3 / 4 " 51- 3 / 4 " 34-3 / 4 " NOT TO SCALE 30" 47 - 3 / 4 " 3" LOGO COMPOSITE SHIELD X SPLIT COVERCOVER LIFT PIN BULK VAULT FEATURES: 30” X 48” X 36” (open floor) (actual dimensions on drawing) BULK VAULT – SHIELD X Split COVER- Tier 22 Load Rated (ANSI/SCTE 77: 2013) (4) Cover locking Auger bolts, Hex (9/16”) or Penta (7/8”h) head with washer (4) Non-Seizing Fastening System, Field Replaceable (4) Embedded Composite Rack Support (1) Lifting slot equipped with stainless steel pin (slot isapproximately 2 ¾”x¾”) (4) Winterized Cable Drop slide (1 ¼” X 1 ¼”) (1) Galvanized Center Beam (2) Logo Disk WEIGHT & SHIPPING: Cover Weight: 50 lbs (Per Half) Box Weight: 129 lbs Assembly Weight : 229 lbs PERFORMANCE TESTING: ANSI/SCTE 77: 2013 - TIER 22 Rated (33,750 lbs) AS3996 – Class C EN124 Class B125 ASTM C1028-07 & AS-4586 (Slip Resistance) 10,000 Hour Xenon-Arc Exposure (No fiber-bloom) ASTM D635-06 (Flammability) GRAVEL BASE TYPICAL DETAIL - #2A BULK304836 BULK VAULT HDPE STRUCTURAL FOAM SHIELD X COMPOSITE COVER CHANNEL - BULK3048363B1420 NP10-5508 TYPICAL DETAIL - #4A PARALLEL CONDUIT DETAIL FOR DOT R/W VARIES VARIES VARIES X VARIES EO P ASPHALT ROADWAY HDPE ROLE PIPE AS SPECIFIED E/W (1) OPTIC CABLE EO P C/ L UNDISTURBED EARTH R/ W R/ W 5' TYPICAL DETAIL - #6C DIRECTIONAL BORE UNDER STATE ROADS TYPICAL DETAIL DIRECTIONAL BORE TIE-IN DETAIL DIRECTIONAL BORE DIRECTIONAL BORE ·BORE FROM EACH DIRECTION IS RUN AT DESIGN DEPTH TO SOME POINT PAST THE INTENDED TIE-IN, THEN TURN UP TO DAYLIGHT. ·TIE-IN POINT IS EXCAVATED, PIPE CUT OFF WHERE THEY CROSS EACH OTHER AT DESIGN DEPTH AND A HIGH PRESSURE COUPLER IS INSTALLED TO CONNECT THE TWO PIPES AT DESIGN DEPTH. ·ALL EXCAVATIONS OR TRENCHES (4) FOUR FEET OR GREATER IN DEPTH SHALL BE APPROPRIATELY BENCHED, SHORED, OR SLOPED ACCORDING TO THE PROCEDURES AND REQUIREMENTS SET FORTH IN OSHA'S EXCAVATION STANDARDS; 29 CFR 1926.650, 1926.651 AND 1926.652 Know what's below. before you dig.Call R CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 11 15 DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC TYPICALS C/ L EO P EO P R/ W R/ W DIRECTIONAL BORE EXISTING GRADEEXISTING GRADE TYPICAL DETAIL - #5 DIRECTIONAL BORE NON-DOT ROADS 10 ' MI N . TYPICAL DETAIL - #9A DIRECTIONAL BORE WITH BRIDGE UNDER CANALS & CREEKS 10' COVER 10' 10' COVER EXISTING GRADE CANAL / CREEK VARIES Know what's below. before you dig.Call R CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 12 15 DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC TEST STATION DETAIL SCHEMATIC 50'50'50' CATHODIC PROTECTION EXISTING GRADEEXISTING GRADE ARMORED FOC CATHODIC PROTECTION EXISTING GRADE COPPER CLAD GROUND ROD (5/8" X 8') TEST STATION WITH FIELD SPLICE #6 GRD-WIRE FROM GROUND ROD (5/8" X 8') TO SPLICE ENCLOSURE CATHODIC PROTECTION EXISTING GRADE COPPER CLAD GROUND ROD (5/8" X 8') TEST STATION WITH COIL FOR FUTURE SPLICE EXISTING GRAVEL COPPER CLAD GROUND ROD (5/8" X 8') TEST STATION HANDHOLE (2.5' X 4' X 3') COPPER CLAD GROUND ROD (5/8" X 8') HANDHOLE (2.5' X 4' X 3') ANCHOR COPPER CLAD GROUND ROD (5/8" X 8') MGNV NOTE: BOND FOC TO GROUND ROD AT RISER POLES AND EVERY 6,600 FEET (11 4 MILES) TEST STATION HANDHOLE (2.5' X 4' X 3') DO W N - G U Y 100' COIL ARMORED FOC & 10M STRAND POLE MGNV NOTE: BOND SUPPORT STRAND TO MGNV AT ALL FUTURE SPLICE LOCATIONS MGNV NOTE: BOND FOC TO MGNV USING COMMSCOPE SUREGROUND GROUND KIT FOR 5/8" CABLE MGNV BOND FOC TO GROUND ROD EVERY 6,600' (11 4 MILES)BOND METALLIC SHIELD TO MGNV EVERY 6,600' (11 4 MILES) AERIAL NOTES: 1.Establish and maintain continuity of all metallic components (strength member, shield, moisture barrier, armor) across all aerial splices. 2.Bond metallic components to the support strand at all splice locations 3.Bond support strand to pole MGNV at all riser poles, fiber loop (2,000') locations for future splice and fiber splice locations 4.Place bonds between all metallic cable components and the support strand at least once every 11 4 miles (6,600 feet). BURIED NOTES: 1.Establish and maintain continuity of all metallic sheath components and strength members in the cable and across all buried splices 2.Bond metallic sheath components and strength members to 5/8" x 8' copper clad ground rod at all buried splices 3.Place 5 8" x 8' copper clad ground rods at all handholes for future splicing and grounding 4.Place bonds between all metallic cable components and copper clad ground rods at least once every 11 4 miles (6,600 feet). 5.Place Cathodic Protection Test Station at all buried fiber cable splices and when bonding fiber metallic cable components to copper clad ground rods every 11 4 miles POLE POLEPOLE 100'100'100'100' 100'100'100' COPPER CLAD GROUND ROD (5/8" X 8') #6 GRD-WIRE FROM IN COMING FOC TO SPLICE ENCLOSURE #6 GRD-WIRE FROM FOC TO GROUND ROD (5/8" X 8') #6 GRD-WIRE TO GROUND ROD (5/8" X 8') SPLICE ENCLOSURE HANDHOLE (2.5' X 4' X 3') 6" GRAVEL 50' COIL HANDHOLE (2.5' X 4' X 3') 6" GRAVEL 50' COIL #6 GRD-WIRE TO FOC #6 GRD-WIRE TO FOC#6 GRD-WIRE TO INCOMING FOC #6 GRD-WIRE TO OUTGOING FOC #6 GRD-WIRE TO GROUND ROD (5/8" X 8') 50' COIL #6 GRD-WIRE FROM OUT GOING FOC TO SPLICE ENCLOSURE #6 GRD-WIRE TO METAL SHIELD OF FOC #6 GRD-WIRE TO GROUND ROD (5/8" X 8') #6 GRD-WIRE TO METAL SHIELD OF FOC BONDING CLAMP 100' COIL 100' COIL 100' COIL BONDING CLAMP MGNV MGNV MGNV ARMORED FOC GOING DOWN POLE BOND STRAND TO MGNV AT ALL RISER POLES SPLICE LOCATIONS BOND STRAND TO MGNV BOND STRAND TO MGNV BOND STRAND TO MGNV MGNV BOND METALLIC SHIELD TO MGNV BOND DOWN-GUY TO MGNV #6 GRD-WIRE & BONDING CLAMPS EXISTING GRAVEL EXISTING GRAVEL ARMORED FOC ARMORED FOC ARMORED FOC ARMORED FOC ARMORED FOC ARMORED FOC ARMORED FOC ARMORED FOC ARMORED FOC & 10M STRAND ARMORED FOC & 10M STRAND NOTE: BOND FOC TO GROUND ROD USING COMMSCOPE SUREGROUND GROUND KIT FOR 5/8" 100' COIL FUTURE SPLICE 100' COIL FUTURE SPLICE 100' COIL EXISTING GRADE EXISTING GRADE BONDING & GROUNDING DETAILS Know what's below. before you dig.Call R CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 13 15 DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC DIRECTIONAL BORE PROFILE 7' DIRECTIONAL BORE DETAIL UNDER GUM BRANCH RD (SR-1308) 36'21' 62' 10 ' 10 ' BP - 1 BPHH HH - 2 8' DIRECTIONAL BORE DETAIL UNDER GUM BRANCH RD (SR-1308) 37'7' 52' 10 ' 10 ' BP - 6 BPHH HH - 4 Know what's below. before you dig.Call R CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 14 15 DRAWING NAME: PROJECT MANAGER: ENGINEERING FIRM: SO/EWO#, EBS# PROJECT: ADDRESS: Gum Branch Rd (U-4906), Jacksonville NC (Revision-1).dwg SOUTH CAROLINA TELECOMMUNICATIONS GROUP HOLDINGS, LLC d/b/a SEGRA Michael Wornom TPRC BROADBAND SO# EWO# / EBS# U-4906 Gum Branch Rd, Jacksonville NC CONFIDENTIAL/PROPRIETARY SHEET: NO. 1 2 3 OF 15 15 Total Underground Rake Off Unit Code & Description Units Estimated Quantity Actual Quantity Total Aerial Rake Off Unit Code & Description Units Estimated Quantity Actual Quantity Know what's below. before you dig.Call R Total Inside Plant (ISP) Rake Off Unit Code & Description Units Estimated Quantity Actual Quantity 96CT FOC 2706' 1-1/4" HDPE 6918' VAULT / HANDHOLE 3 GROUND ROD 3 LOCATE MARKER POST 2 MARKER POST 3 FOSC 450D SPLICE CLOSURE 2 72CT SPLICE TRAY 2 TALL BASKET 2 MATERIAL TOTALS Cable Placement, Splicing, Testing ETC Rake Off Unit Code & Description Units Estimated Quantity Actual Quantity Material Rake Off Unit Code & Description Units Estimated Quantity Actual Quantity OSP 96CT. FIBER OPTIC CABLE UNDERGROUND 2306' OSP 96CT. SERVICE COIL UNDERGROUND 100' OSP 96CT. SLACK LOOP UNDERGROUND 300' UNDERGROUND TOTAL (96CT):2706'