Loading...
HomeMy WebLinkAboutSW8970713_COMPLIANCE_20080709 (2)STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 cl\_) O_ � DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ❑ HISTORICAL FILE © COMPLIANCE EVALUATION INSPECTION DOC DATE 200%010c� YYYYMMDD STATE OF NORTH CAROLINA Department of Environment and Natural Resources WIRO Regional Office FILE ACCESS RECORD 192 SECTION SWP DATE/TIME NAME REPRESENTING qz-Sz Guidelines for Access: The staff of the Regional Office is dedicated to making public records in our custody readily available to the public for review and copying. We also have the responsibility to the public to safeguard these records and to carry out our day-to-day program obligations. Please read carefully the following before signing the form. 1. Due to the large public demand for file access, we request that you call at least a day in advance to schedule an appointment for file review so you can be accommodated. Appointments are scheduled between 9:00 a.m. and 3:00 p.m. Viewing time ends at 4 45 p.m. Anyone arriving without an appointment may view the files to the extent that time and staff supervision are available. 2. You must specify files you want to review by facility name or incident number, as appropriate. The number of files that you may review at one appointment will be limited to five. 3. You may make copies of a file when the copier is not in use by the staff and if time permits. There is no charge for 25 or less copies.: cost per copy after the initial 25 is 2.5 per copy. Payment is to be made by check, money order, or cash in the administrative offices. 4. Files must be kept in the order you received them. Files may not be taken from the office. No briefcases, large totes, etc. are permitted in the file review area. To remove, alter, deface, mutilate, or destroy material in public files is a misdemeanor for which you can be fined up to $500.00. 5. In accordance with GS 25-3-512, a $25.00 processing fee will be charged and collected for checks on which payment has been refused. 6. The customer must present a photo ID, sign -in, and receive a visitor sticker prior to reviewing files. FACILITY NAME COUNTY 1.//y7T�Qd� �i 5 ��' 2. 3. 4._ 5 I-7 9 o 8 3 Q S S ature/Name of Firm or Business Date Time In. Time Out lease attach business card to form if available) # Copes: Amt. Pd: May 20,2008 Pat C. Durrett Environmental Specialist 12.7 Cardinal Drive Extension Wilmington, NC 28405 Notice of Inspection - Non -Compliance Status Antiqua Apartments Stormwater Project No. SW8970713 New Hanover County We have received your inspection report on the above. We are in the process of requesting and receiving quotes to correct the deficiencies and should be back in compliance within thirty days. Sincerely, Don Senick Maintenance Director Rmcmivmn MAY 2 1 gggr BY: 2 pO 8 1 61 O-A S. Third Street P.O. Box 1229 • Wilmington, NC 29402 Tole 91 0-261 •5030 • Fax 910.261 •91 69 Michael F. Easley, Governor William G. Ross Jr., Secretary rNorth Carolina Department of Environment and Natural Resources `( Coleen N. Sullins Director Division of Water Quality April 14, 2008 Mr. Nathan Sanders, President Sanco of Wilmington P.O. Box 3167 Willmington, NC 28406 Notice of Inspection -NON-COMPLIANCE STATUS Antiqua Apartments Stormwater Project No. SW8970713 New Hanover County Dear Mr. Sanders: Please find attached a copy of the completed form entitled "Stormwater Compliance Inspection Report". The report summarizes the findings of a recent inspection of the project's stormwater controls conducted on April 2, 2008 to determine compliance with Stormwater Permit Number SW8970713 issued on January 9, 1998. The required actions that are necessary to bring this site into compliance are noted under the Comments section of the report. Please inform this Office in writing within fifteen (15) days of the specific actions that will be undertaken and the time frame that will be required to correct the deficiencies. Failure to provide the requested information, when required, may initiate enforcement action. If you have any questions please contact David Cox at the Wilmington Regional Office, telephone number (910) 796-7318. Sincerely, Pat C. Durrett Environmental Specialist PCD/encl: S:\WQS\STORMWAT\INSPECT\Pats inspections\SW8970713 cov Itr cc: Wilmington Regional Office Jennifer Philligin, Tribute Properties Nelicarolina Al tura!/!l North Carolina Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Phone (910) 796-7215 Customer Service Wilmington Regional Office Internet: www.newateraualitv.ore Fax (910)350-2004 1-877-623-6748 An Equal OpporlunilylAffirmative Action Employer — 50% Recycled110% Post Consumer Paper STATE STORMWATER INSPECTION REPORT Project Name: Antigua Apartments Permit No: SW8970713 Expiration date: 1/9/08 Contact Person: Jennifer Philligin Phone No: 910-794-9849 County: New Hanover Center of Project GPS: Lat: 340 10' 09.06 "N Long: 77" 55' 42.53 "W Facility Address: 3810 Portifino Court City: Wilmington Zip: 28412 (If multiple basins exist, specify basin(s): Entry time: 9:10 am ® pm ❑ Exit time: 10:10 am ® pm ❑ Date: 4/2/08 . Method of Treatment: (check one) ® Wet Detention ❑Dry Detention ❑ Bioretention ❑ Wetland ❑ Sandfilter ❑Swale ❑ Pocket Wetland ❑ Level Spreader ❑ Permeable Pavement ❑ Infiltration Basin Other: ❑ Receiving Waters: Barnards Creek . Classification: C-Sw River Basin: Cape Fear GENERAL QUESTIONS FILE REVIEW 1. A signed copy of the Engineer's certification is in the files: 2. A signed copy of the Operation & Maintenance Agreement is in the files: 3. A copy of the recorded deed restrictions is in the files: SITE VISIT 1. Drainage area is consistent with the permit: 2. Built -upon area to drainage area is consistent with the permit: 3. All built -upon area (as permitted) is graded such that the runoff drains to the system: 4. The outlet structure is located per the approved plans: 5. The trash rack is provided on the outlet/bypass structure: 6. The trash rack is free of debris and excess trash: 7. All slopes are grassed with permanent vegetation: 8. Vegetated slopes are no steeper than 3:1 9. The inlets are located per the approved plans and do not cause short-circuiting of the system YES NO NIA NE YES NO NA NE 10. Access points are clear and well maintained: ® ❑ ❑ ❑ 11. Forebay is free of excessive sediment: ❑ ® ❑ ❑ 12. Banks are stable with no erosion present: ❑ ® ❑ ❑ 13. Vegetation and trash have been removed as needed: ❑ ® ❑ ❑ 14. Drawdown device is correctly sized per the approved plans: ® ❑ ❑ ❑ 15. Grass is mowed (not scalped) as required: ® ❑ ❑ ❑ 16. All required parts of the system are provided (such as vegetated shelf and a forebay): ® ❑ ❑ ❑ 17. The swale or outlet bypass is in the correct place and is in good condition: ® ❑ ❑ ❑ 18. Vegetated shelf is 6:1 and properly vegetated: ® ❑ ❑ ❑ 19. Invasive species/tree control is provided as needed ❑ ® ❑ ❑ 20. Tree pruning, mulch and plant replacement are provided as needed in the bioretention basin: ❑ ❑ ® ❑ 21. Permeable pavement has had regular sweeping and vacuuming: ❑ ❑ ® ❑ 22. Gravel replacement is performed as needed: ❑ ❑ ® ❑ 23. Excessive landscape debris (grass clippings, leaves, & sediment) are controlled: ❑ ❑ ® ❑ 24. Large stemmed vegetation is kept off of the level spreader: ❑ ❑ ® ❑ 25. Sediment and debris is removed from behind the lip of the level spreader on a routine basis: ❑ ❑ ® ❑ 26. Maintenance records are available for inspection: ❑ ® ❑ 0 COMMENTS: (each NO answer should have a comment) 1. Your permit expired on January 9, 2008. You are reminded that the operation of a stormwater treatment facility without a valid permit is a violation of NC General Statute 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $10,000.00 per day. To date, this Office has not received your renewal request. This should be submitted at once. 2. We have not received a copy of the engineer's certification as required by your permit. This must be included with your renewal request. 3. There is a copy of an old Operation & Maintenance agreement in the files however, a new copy must be submitted with your renewal request. 4. Your pond has a large accumulation of surface algae which can plug your outlet pipe. You may want to place a baffle around the pipe to help with this situation. S. Some of your banks and sideslopes have erosion and need to be repaired and reseeded. 6. You should evaluate the levels of sediment in your pond and muck out if necessary according to your permit requirements. 7. The large woody vegetation at inlet and on sideslopes should be cut down. 8. The forebay berm has washed out and should be repaired and returned to design specifications. 9. There is piping and irrigation pumps on site that were not on the approved plans. This should be addressed in your renewal req uest. 10.There were no maintenance records available on the inspection date. inlet swale to pond large woody vegetation at inlet and around pond should be cut. forebay berm has washed out and needs to be repaired irrigation equipment and piping not shown on plans bank and sideslope erosion that should be repaired and reseeded main pond with heavy algae accumulation sideslope erosion algae so heavy sediment levels can't be seen outlet structure outlet pipe cannot be found in pond due to algae some trash on rach outlet structure pipe covered sideslope erosion erosion and woody vegetation irrigation pump house YES NO Compliant Non -Compliant NOV sent Date sent Inspectors name& signature: Pat C Durrett Date: 4/2/08