HomeMy WebLinkAboutSW8081209_HISTORICAL FILE_20160506 (2)STORMWATER DIVISION CODING SHEET
POST -CONSTRUCTION PERMITS
PERMIT NO.
SW8 09 12 09
DOC TYPE
❑ CURRENT PERMIT
❑ APPROVED PLANS
Lrl HISTORICAL FILE
❑ COMPLIANCE EVALUATION INSPECTION
DOC DATE
2016 0 g, 0 6
YYYYMMDD
i
Energy, Mineral
and Land Resources
ENVIRONMENTAL QUALITY
May 6, 2016
Anthony W. Sydes, President
Clearly Development, Inc.
P.O. Box 7227
Jacksonville, NC 28546
Subject: Approved Plan Revision
Riverside Development
Stormwater Permit No. SW8 081209
New Hanover County
Dear Mr. Sydes
PAT MCCRORY
Governor
DONALD R. VAN DER VAART
Secrewry
TRACY DAVIS
Director
top
JUN 8 ?020
On April 28, 2016, the Wilmington Regional Office received a complete request to revise the approved
plans for Stormwater Management Permit Number SW8 081209. The revisions include modification of
the drainage network from the original plans. It has been determined that a formal permit modification is
not required for the proposed changes. We are forwarding you an approved copy of the revised plans for
your files. Please replace the old approved plan sheets with the new sheets attached.
Please be aware that all terms and conditions of the permit issued on March 23, 2015 shall remain in
full force and effect, including the requirement to record the deed restrictions, as per the signed,
notarized form attached Please also understand that the approval of this revision to the approved
plans or to the permit for the subject State Stormwater project is done on a case -by -case basis. Any
other changes to this project must be approved through this Office prior to construction. The issuance
of this plan revision does not preclude the permittee from complying with all other applicable
statutes, rules, regulations or ordinances which may have jurisdiction over the proposed activity, and
obtaining a permit or approval prior to construction.
If you have any questions concerning this matter, please do not hesitate to call me at (910) 796-7215.
Sincerely,
Steven G. Pusey
Environmental Engineer
O-GDS\sgp: \\\Stormwater\Permits & Projects\2016\081209 HD\2016 05 permit pr 081209
cc: Jason Houston, PE— Parker & Associates,lnc.
New Hanover County Building Inspections
Wilmington Regional Office
Stale of North Carolina I Environmental Quality I Energy, Mineral and Land Resources
127 Cardinal Drive Extension I Wilmington, NC 28405
910 796 7215 T 1910 330 2004 P I bttn'Ooonal nedenr.ma/web/Ir/
High Density Residential Subdivisions 11JECEIVE
Deed Restrictions & Protective Covenances APR 2 8 2016
In accordance with Title 15 NCAC 2H.1000 and S.L. 2006-246, the Stormwater Mana ment Regulations,
deed restrictions and protective covenants are required for High Density Residential ' wherep
lots will be subdivided and sold and runoff will be treated in an engineered stormwater control facility. Dee
restrictions and protective covenants are necessary to ensure that the development maintains a "built -upon"
area consistent with the design criteria used to size the stormwater control facility.
I; Anthony W. Svdes , acknowledge, affirm and agree by my signature below, that I will cause
the following deed restrictions and covenants to be recorded prior to the sale of any lot:
The following covenants are intended to ensure ongoing compliance with State Stormwater
Management Permit Number SW8 081209 , as issued by the Division of Energy, Mineral and Land
Resources under the Stormwater Management Regulations.
2. The State of North Carolina is made a beneficiary of these covenants to the extent necessary to
maintain compliance with the stormwater management permit.
3. These covenants are to run with the land and be binding on all persons and parties claiming under
them.
4. The covenants pertaining to stormwater may not be altered or rescinded without the express written
consent of the State of North Carolina, Division of Energy, Mineral and Land Resources.
5. Alteration of the drainage as shown on the approved plan may not take place without the concurrence
of the Division of Energy, Mineral and Land Resources.
6. The maximum allowable built -upon area per lot is 3,500 square feet. This allotted amount includes
any built -upon area constructed within the lot property boundaries, and that portion of the right-of-way
between the front lot line and the edge of the pavement. Built upon area includes, but is not limited to,
structures, asphalt, concrete, gravel, brick, stone, slate, coquina and parking areas, but does not
include raised, open wood decking, or the water surface of swimming pools.
OR, if the proposed built -upon areas per lot will vary, please REPLACE #6 above with the following:
6. The maximum built -upon area per lot, in square feet, is as listed below:
Lot # BUA Lot # BUA Lot # BUA Lot # BUA
This allotted amount includes any built -upon area constructed within the lot property boundaries, and
that portion of the right-of-way between the front lot line and the edge of the pavement. Built upon area
includes, but is not limited to, structures, asphalt, concrete, gravel, brick, stone, slate, coquina and
parking areas, but does not include raised, open wood decking, or the water surface of swimming
pools.
Each lot will maintain a 30"" foot wide vegetated buffer between all impervious areas and surface
waters.
••50 foot for projects located in the 20 coastal counties.
8. All runoff from the built -upon areas on the lot must drain into the permitted system. This may be
accomplished through a variety of means including roof drain gutters which drain to the street, grading
the lot to drain toward the street, or grading perimeter swales to collect the lot runoff and directing them
into a component of the stormwater collection system. Lots that will naturally drain into the system are
not required to provide these additional measures.
FomiDRPC-3 Rev.2 05Nov2009 Page 1 of2
High Density Residential Subdivisions
Deed Restrictions & Protective Covenances
Date: L22a 01 (p
Vl , a Notary Public in the
State of IV o cf-� CArD I i n a Countyof O/ 6l o
do hereby certify that ��ho� S U �lJ personally appeared
before me this the a hP day of (I 20and acknowledge
the dN execution of the foregoing instrument. Witness my hand and official seal,
U �
� n {�
VV9CC
toe * %OTA9y
mmission expires
o' '°Ugl C r'
1
WCOI IX ``,��
DECEIVE
APR 2 6 2016
BY;_
Form DRPC-3 Rev.2 05Nov2009 Page 2 of?
PARKER & ASSOCIATES, INC.
Consulting Engineers - Land Surveyors - Land Planners
306 New Bridge Street • P.O. Box 976
Jacksonville, NC 28541-0976
910-455-2414 • Fax:910-455-3441
Firm License Number F-0108
LETTER OF TRANSMITTAL
TO: Mr. Steven G. Pusey, Environmental Engineer DATE:
NC DEQ REF:
127 Cardinal Drive Extension
Wilmington, NC 28405
WE ARE SENDING YOU:
April 25, 2016
Riverside Development
Deed Restriction Form
One (1) signed original Deed Restriction Form for the above referenced project.
DELIVERY VIA:
O
Regular Mail
❑
Hand
❑
Federal Express
❑
UPS Overnight
❑
UPS Ground
❑
Other
THESE ARE TRANSMITTED AS CHECKED 13ELOW:
❑
For Approval
x❑
As Requested
❑
For Your Use
❑
For Bids Due
❑ Other
COMMENTS:
❑ For Review and Comment
ECG' Y9
Administrative Assistant
Copies To: Mr. Anthony Sydes- Clearly Development, Inc.
KRP CF (P), JAN
(if enclosures are not as noted, kindly notify us at once)
Secretary.0 I ,KRP.I.O'1'. Pusey.It iverside.DeedRestrictionForm.4.25. 16
EMAIL ADDRESS: TEXT MESSAGES To: oaitexi(albizeexr.com MAPS AND PLANS TO: oaidraff a�.bizec.recom
• ENVIRONMENTAL ENGINEERING • STORMWATER, WATER & WASTEWATER SYSTEMS
• FEASIBILITY & DEVELOPMENT CONSULTING • GLOBAL POSITIONING SURVEYS • SUBDIVISION & CONSTRUCTION PLANS
Fusey, Steven
From:
Pusey, Steven
Sent:
Thursday, April 21, 2016 4:39 PM
To:
'Jason Houston'
Subject:
RE: Riverside Development, SW8 081209
I will try to look through our file again too, concerning the allocation of built -upon area, etc.
Thanks,
Steve
cft. G. A
Environmental Engineer
Division of Energy, Mineral and Land Resources — State Stormwater Program
Department of Environmental Quality
910 796 7215 office
910 796 7334 direct
sleven. nusey(a),ncde nr.gov
127 Cardinal Drive Ext.
Wilmington, NC 28405
lnnyy6in Mnnl
Ewdo gill -and l Ond Rr,ouu n
... -.m ... uw....
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties.
Before printing this email, please consider your budget and the environment.
From: Jason Houston [mailto:jhouston@bizec.rr.com]
Sent: Thursday, April 21, 2016 4:23 PM
To: Pusey, Steven <steven.pusey@ncdenr.gov>
Cc: Parker & Associates, Inc. <paitext@bizec.rr.com>
Subject: Re: Riverside Development, SW8081209
Steve,
As for Item 3.1 From the calculations that I have seen on the original plans and the original drainage area map that was
submitted to NCDEQ, the offsite BUA was assumed to be 100% impervious. This is by all means pretty conservative, and
explains the pond size for pre/post flood control for New Hanover county. As stated before the pond is still twice as big
as it needs to be to handle the BUA. The original engineer did this because they(the developer) has no control of the
offsite areas. We couldn't limit them to what they might want to do, plus I also think it was part of the "agreement"
between the two parties. They get a free pond, and the developer gets to have access to the property in the back.
We have had no working relationship with the previous engineer (despite paying him several thousand dollars to
help). I will look through our old permits files and plans to see if I can find any additional documentation that will satisfy
this question.
Itin tt4.` I will get anew deed restriction form filled out signed and sent to you for the Lot BUA. Nothing has been
recorded to date.
Thanks...
Jason Houston PE, President
Parker & Associates, Inc
Jacksonville NC, 28540
Firm License Number F-0108
910-455-2414 - Office
910-455-3441 - Fax
www.parkerengineering_andsurveying.corn
On 4/21/2016 3:46 PM, Pusey, Steven wrote:
Jason,
I finally got some time to review your resubmittal for Riverside. I have the following questions
pertaining to our previous correspondence:
Item
3.1. Confirm by calculations that offsite area is accounted for in Pond #2 design: Do you
have a breakdown of the offsite drainage area anywhere? Also, is there a summary of built -
upon area showing a breakdown including offsite BUA?
4. For new lots, a notarized form should be filled out stating that deed restrictions will be
recorded in the future, listing BUA per lot, etc. Or, if they have already recorded, please submit
a copy of the recorded deed restriction documents from the Covenants & Restrictions. Does
this document need to be amended?
Thanks,
Steve
crt� G. -P
Environmental Engineer
Division of Energy, Mineral and Land Resources — State Stormwater Program
Department of Environmental Quality
910 796 7215 office
910 796 7334 direct
steven.ouseyCo?ncdenr.00v
127 Cardinal Drive Ext.
Wilmington, NC 28405
KID
unJlanO f:+vnrtr.
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties.
Pusey, Steven
From: Pusey, Steven
Sent: Thursday, April 21, 2016 3:47 PM
To: Jason Houston Qhouston@bizec.rr.cwm)
Subject: Riverside Development, SW8 081209
Importance: High
Jason,
I finally got some time to review your resubmittal for Riverside. I have the following questions pertaining to
our previous correspondence:
Item
3.1. Confirm by calculations that offsite area is accounted for in Pond #2 design: Do you have a breakdown
of the offsite drainage area anywhere? Also, is there a summary of built -upon area showing a breakdown
including offsite BUA?
4. For new lots, a notarized form should be filled out stating that deed restrictions will be recorded in the
future, listing BUA per lot, etc. Or, if they have already recorded, please submit a copy of the recorded deed
restriction documents from the Covenants & Restrictions. Does this document need to be amended?
Thanks,
Steve
cry q. P"Ac .
Environmental Engineer
Division of Energy, Mineral and Land Resources — State Stormwater Program
Department of Environmental Quality
910 796 7215 office
910 796 7334 direct
Steven. ousevCrD ncdenr.00v
127 Cardinal Drive Ext.
Wilmington, NC 28405
Acdt.dRnous
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties.
® Before printing this email, please consider your budget and the environment.
, 1. -. - -, 1 1%, Oil -q
if 0 109 A 12 NMI
nil owpu O!OLL7�.
Lwool' mtjai.?i vlq rum wrxmcr;- -- f—i; C Lla.. -J! u
20d"
LPSUV2'
,iUR '?!1'; 01 lee 14c, 'JO q;PGA ;MPL a IS11A =Lq7t;- UICW S- ' 0r� ,,
.y 1 -1 Q !C4 '; J jf-LI W I;:-:: 'I q=j '" 'r TP20 Q! P L' 7OUT q '' 0':
'U"wo caml; Orr
0 W I 'cc -Q Mir V 1P
T T' Cuala pi I-yrqwpow rpof oyp jyo I7 vccD2u[Gq vn w bauq g qw?2!j: �C holl la-v.., J PLuj;SCjoinv
I I t, ,
MI) -09 4t W '0 CQ
imu
loh." 13.!,TCF
�trin;
PARKER & ASSOCIATES, INC.
Consulting Engineers - Land Surveyors - Land Planners
306 New Bridge Street • P.O. Box 976
Jacksonville, NC 28541-0976
(910)455-2414 • Fax:(910) 455-3441
www.parkerengineeringandsurveying.corn
Firm License Number F-0108
VIA EMAIL AND MAIL
March 3, 2016
Mr. Steven Pusey
NC DEQ
127 Cardinal Drive Extension
Wilmington, NC 28405
;raping Horizon
RE: Riverside Development
Stormwater Additional Information Request
SW Application No. SW8 081209
New Hanover County, NC
Dear Mr. Pusey:
This letter is in response to your letter dated
referenced project.
y' MAR a i 2b16
February 16, 2016 for the above
J1. The project drainage area has not changed since NC DEQ issued the original permit,
it includes all the areas mentioned in your additional information request letter.
2. We have the same number of lots. The only revisions we made were "cleaning up"
3.
some of the odd shapes on a few of the lots to be more uniform for house
construction. The BUA for the lots will remain the same.
The pond has not changed. The original permit and drainage area shows
687,032 square feet of offsite drainage area tributary to the pond, of which it
all is assumed to be Impervious Area. It is listed in the original permit. Pond
#2 serves very little for the Riverside development and is mostly for the
offsite area. The ponds are also very much oversized. This is due in part to
the New Hanover County flood control requirements that restrict post
development peak flows. Let's look at pond #2:
EMAIL ADDRESS:'1'I?X'I' DIESSAGES'1'O: paitextehizee.mcom MAPS and PLANS TO: paidr.ift@[,izec.rr.com
ENVIRONMENTAL ENGINEERING +SI'ORMWATER, WATER AND WASTEWATER SYSTEMS
♦ EEASIBILITYAND DEVELOPMENT CONSULTING ♦ GLOBAL POSITIONING SURVEYS ♦ SUBDIVISION AND CONSTRUCTION PLANS
Riverside Development-Stormwater Additional Information Request
Page Two (2)
March 3, 2016
Total Drainage Area= 1,514,008 ft'
Total BUA to pond = 851,192 ft2
% Impervious = 851,192/1,514,008 = 56.2%
Pond SA/OA charts for 90%TSS Removal Rates with a 3 ft. average
depth at 60% BUA = 7%
Surface area required = 0.07 (1,514,008 ftZ) = 105,980 ft'
Surface area provided = 199,723 ftZ
So we have roughly 88% MORE surface area than what is required. I would like to think
that this would suffice.
V/b. The swale continues on and enters Pipe H4. See attached plan.
Jc. It may be difficult to see on a plan copy but between Lots 37/38, 45/46 and
54/55 there are drainage pipes located on the property lines. The invert
elevations are the pipe inverts at these locations. The pipes are F1, E1 and B1
on the respective property lines.
4. All offsite areas are calculated as having 100% Impervious Surface Areas. I don't see
much need in recording the covenants when they can cover as much or little as they
want/need.
5. The developer has agreed to build the pond and provide maintenance costs as the
deal to allow a road to be constructed through their property otherwise there would
be no project.
6. As previously discussed, let's look at Pond H2 storage volume using the average -end
area method to calculate volume:
- PPE = 20.5—199,723 ft'
21.0 — 214,204 ftZ
- (199,723 ftZ + 216,395 ftZ) _ 2 x 0.5 ft (depth) = 103,481 ft'
21.25 = 216,222 ftZ
- (214,204 ftZ + 216,395 ftZ) _ 2 x 0.25 ft (depth) = 53,824 ft'
- Total Temp Pool Volume = 157,305 ft'
- Required Storage Volume = (1.5 in/12 in/ft) x 0.56 x 1,514,008 ftZ
= 105,222 ft'
LIAR 0 7 201G
Riverside Development- Stormwater Additional Information Request
Page Three (3)
March 3, 2016
As you can again see, the storage volume for the pond is much greater than is required.
7. The easement is shown; however, since it corresponds to the surrounding fence, it
would be difficult to see in a copy of the plans.
Please find enclosed two (2) copies of the Grading Plans and Preliminary Plats. Also find
enclosed a copy of the Drainage Area Map that corresponds to the original Drainage Area Map
for this project.
Please keep in mind that this project has a long history and we have had what I would
describe as a poor relationship with the original engineer. Lucky for both of us (Developer & NC
DEQ) the ponds were oversized greatly enough to provide adequate stormwater treatment for
our needs, the drainage area's needs, plus much more.
If you have any questions, please contact me.
Sincerely,
PARKER ASSOCIAT NC. ,+
Jas A. H ston, PE
Enclosures
ec: Mr. Anthony Sydes- Clearly Development, Inc. (Paperwork Only)
xc: CF (P)
JAH/krp
Sec retary.C1.JAH. Letter. Pusey.Riverside Development.S WAdd.Info.3.3.16
ECFR E
MdR a y 2016
BY:
Energy, Mineral
and Land Resources
ENVIRONMENTAL OUALITY
February 16, 2016
Anthony W. Sydes
Clearly Development, Inc.
P.O. Box 7227
Jacksonville, NC 28546
Subject: Request for Additional Information
State Stormwater Application No. SW8 081209
Riverside Development
New Hanover County
Dear Mr. Sydes:
PAT MCCRORY
Gm,erntr
DONALD R. VAN DER VAART
Secretory
TRACY DAVIS
Director
The Wilmington Regional Office received and accepted a Plan Revision for State Stormwater
Management Permit SW8 081209 on November 20, 2015. A preliminary in-depth review of that
information has determined that the application is not complete. The following information is needed to
continue the stormwater review:
Supporting Information requirements applicable to all projects:
J1. 02H.1003(g)(5) and 02H.1005(d) - Delineate all relevant boundaries including drainage
areas, SHWT, coastal wetlands, property/project boundaries and drainage easements.
Coastal wetlands above the mean high water line must be excluded from the project area
prior to calculating density. Recommendation: The required vegetated buffer should be
delineated. The definition of the vegetated buffer can be found in 02H.1002(23). If there
are no coastal wetlands on site, please note so on the plans. Lot lines should be
considered a `property boundary".
For this project, you will need to provide a drainage area map showing all onsite
and offsite areas. The offsite area should include all of Wrightsboro Plaza,
including both of the entrance roads off Hwy 117. In addition, there are 3 offsite
lots on the north side of the property (Advance Auto, fronting Hwy 117) and 2 lots
behind (undeveloped) that should be included as offsite development.
f2. 02H.1003(g)(6) — Delineate the existing and the proposed built -upon area including
roads, parking areas, sidewalks, buildings, etc.
Please provide calculation of the BUA, if any lots have changed, etc.
3. 02H. I 003(g)(7) — Provide technical information showing final numbers, calculations,
assumptions, drawings and procedures associated with the stormwater management
measures including but not limited to: Built -upon area, runoff coefficients, runoff
volume, runoff depth, flow routing, inlet and outlet configuration (if applicable), and
other applicable information as specified.
Ol. Confirm by calculations that all offsite area is accounted for in Pond #2 design.
✓2. Swale 3-3 appears to end at the sewage pump station, then picks up again at a
RCD on the other side of the building. Please explain how this will work.
3. RCDs on the north property line show inverts in. Is there supposed to be a yard
inlet at those locations? Special design of check dam? Please advise.
State of North Carolina I Environmental Quality I Energy, Mineral and Land Resources
127 Cardinal Ems Extension I Wilmington, NC 28405
910 796 7215 T 1 910 350 2004 f I htmJ/tonal ncdenr.orFJweb/U/
Clearly Development, Inc.
February 16, 2016
Stormwater Application No. SW8 081209
J 4. 02H. I 003(g)(9) — Provide recorded deed restrictions and protective covenants. As an
alternative, proposed deed restrictions and protective covenants and a signed agreement
to provide the final recorded documents shall be accepted when final documents are not
available at the time of submittal. Per 02H.1003(d)(1) and (2), the permit requires
recorded deed restrictions and protective covenants to ensure that the development
activities are maintained consistent with the approved plans and specs. Recommendation:
The recorded language will necessarily need to limit the BUA (per lot for subdivisions
and per BAP for non -subdivisions), limit the addition of driveway piping, prohibit the
piping of any vegetated conveyances (low density and curb outlet swales), stipulate the
width of the vegetated buffer, prohibit the construction ofBUA in the buffer, and provide
the enforcement authorityfor any individual or entity who fails to comply with the
stormwater permit or the rules. The statements will vary depending on whether the
project is high density or low density. The Division has prepared boilerplate language for
each situation for your use.
/ For this project, as noted in the previous inspection, copy of the recorded deed
✓/ restrictions needs to be submitted for as much of the property as possible, including'
offsite lots. For new lots, a notarized form should be filled out stating that deed
restrictions will be recorded in the future.
General Engineering Design Criteria for all projects. Session Law 2008-21 1 Section 2(b.)(4) all
stormwater management structures shall be designed per the requirements of 02H.1008(c):
/ 5. 02H.1008(c)(]) —The size of the system must take into account the runoff at the ultimate
/ built -out potential from all surfaces draining to the system, including any off -site
drainage. Recommendation: if the offsite drainage is coming from property that is not
owned by the applicant or is not part of the development project and there is no written
maintenance cost -sharing agreement or a recorded deed restriction limiting BUA
between the parties to treat that amount of BUA in the proposed system, the offsite
drainage should be rerouted such that it bypasses the proposed stormwater system. If
there is an agreement/or and a deed restriction, request that the applicant provide
copies.
6. 02H. 1008(c)(1) — The storage volume of the system shall be calculated to provide for the
most conservative protection using any approved runoff calculation methods.
J 7. 02H. I 008(c)(3) - Locate all stormwater management structures in recorded drainage
easements for the purposes of operation and maintenance and provide recorded access
easements to the nearest public right-of-way. These easements shall be granted in favor
of the party responsible for operating and maintaining the stormwater management
structures. Recommendation: the runoff collection system ofpipes, ditches, and swales
are considered a stormwater management "structure " and must be located in a recorded
drainage easement, dedicated common area, or public right-of-way.
I noticed that there didn't appear to be an easement around the relocated sewage
pump station. Please advise.
Please remember that a change to one number may have a domino effect on other numbers. Please check
all plans, calculations and forms to ensure that the numbers are consistent throughout.
Please note that this request for additional information is in response to a preliminary review. The
requested information should be received in this Office prior to March 16, 2016 or the application will be
returned as incomplete. The return of a project will necessitate resubmission of all required items,
including the application fee.
Page 2 of 3
State Stormwater Permit No. SW8
091,uI Page 3 of
If you need additional time to submit the information, please mail, email or fax your request for a time
extension to the Division at the address and fax number at the bottom of this letter. The request must
indicate the date by which you expect to submit the required information, which shall be no later than 30
days past the original due date. The Division is allowed 90 days from the receipt of a completed
application to issue the permit.
The construction of any impervious surfaces, other than a construction entrance under an approved
Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement
action pursuant to NCGS 143-215.6A.
Please reference the State assigned application number on all correspondence. If you have any questions
concerning this matter please feel free to call me at (910) 796-7215 or email me at
steven.pusey@ncdenr.gov.
Sincerely,
Steve G. Pusey
Environmental Engineer
GDS/sgp: \\\Stormwater\Permits & Projects\2008\081209 HM2016 02 addinfo 081209
cc: Jason Houston, PE— Parker & Associates
Wilmington Regional Office Stormwater Permit File
Page 3 of 3
Casmer, Jo
From: Casmer, Jo
Sent: Friday, December 04, 2015 10:18 AM
To:'leahquinn@sydescommunities.com'; Inc., Parker & Associates,
Subject: Riverside Development; Stormwater Permit SW8 081209
The Wilmington Regional Office of the Division of Energy, Mineral, and Land Resources (Stormwater Section)
received the Stormwater Permit Plan Revision Application on November 20, 2015. The project has been assigned
to Steve Pusey and you will be notified if additional information is needed.
Jo Casmer
Administrative Assistant for DEMLR/Stormwater Section
North Carolina Department of Environmental Quality
Department of Environmental Assistance & Customer Service
910 796-7336 office
910 350-2004 fax
io casmer(Mncdenr.00v
127 Cardinal Drive Extension
Wilmington, NC 28405
:>"Nothing Compares---,
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties.
E
lox
L;fj. d. ;-
iJL,
I C
DEMLR USE ONLY
Date Received
Fee Paid (express only)
Permit Number
1
f� a ZZ22
State of North Carolina
Department of Environment and Natural Resources
Division of Energy, Mineral and Land Resources
STORMWATER MANAGEMENT PERMIT PLAN REVISION APPLICATION FORM
This form may be photocopied for use as an original
I. GENERAL INFORMATION
1. Stormwater Management Permit Number: SW8 081209
2. Project Name:
3. Permit Holder's name (specify the name of the corporation, individual, etc.): BY:
Clearly Development Inc
4. Print Owner/Signing Official's name and title (person legally responsible for permit):
Anthony W. Sydes, President
5. Mailing Address for person listed in item 2 above:
GEBV
NOV 2 0 2015
City: Jacksonville State:NC Zip:28546
Phone: (910 ) 455-6956 Fax: (910 ) 455-6325
Email:lealiquitiii@sydescominunities.com
H. PLAN REVISION INFORMATION
1. Summarize the plan revision proposed (attach additional pages if needed):
The drainage network was re -designed from the original plans.'rhe areas and ponds have not changed.
III. SUBMITTAL REQUIREMENTS
Only complete application packages will be accepted and reviewed by the Division of Energy, Mineral and
Land Resources (DEMLR). A complete package includes all of the items listed below. The complete
application package should be submitted to the DEMLR Office that issued the permit.
1. Please indicate that you have provided the following required information by initialing in the space provided
next to each item.
I Is
• Original & 1 copy of the Plan Revision Application Form
• Two (2) copies of revised plans (must be revisions of original approved plan sheet(s))
If applying for Excess review (only available in 20 coastal counties): /�
• Application fee of $500.00 (made payable to NCDENR) 0/4
VI. APPLICANT'S CERTIFICATION
1, (print or type name of person listed in General Information, item 3) Anthony IF. Sydes
certify that I have authorized these plan revisions and that the information included on this plan revision
application is, tot best of my knowledge, correct and complete.
Signature: Date:__ ►►_LI"I►��
Plan Revision Form Rev. Oct. 31, 2013
PARKER & ASSOCIATES, INC.
Consulting Engineers - Land Surveyors - Land Planners
306 New Bridge Street • P.O. Box 976
Jacksonville, NC 28541-0976
(910) 455-2414 • Fax: (910) 455-3441
w w w. parkere n gi neeri n gand surveyi ng.com
Firm License Number F-0108
Mr. Steven Pusey
NC DEQ-DEMLR
127 Cardinal Drive Extension
Wilmington, NC 28405
RE
Dear Mr. Pusey:
Please find enclosed the following items:
November 19, 2015
�ECEUVE
j I NOV 2 0 2015
Riverside Development
New Hanover County
SW Permit No.SW8-081209
Stormwater Plan Revision
- One (1) original and one (1) copy of the Stormwater Management Plan Revision
Application Form.
- Two (2) sets of Plan Sheets 1-7 and 29-31 of 31.
If you have any questions or need any additional information please contact me.
Sincerely,
Enclosures
xc: Anthony W. Sydes (Paperwork Only)
CF (P), LAM (Paperwork Only)
JAH/krp
Secretary. C3.IAH.Pusey. Riverside Development.SW Plan Revision. 11. 18. 15
EMAIL ADDRESS: TEXT MESSAGES TO: uaitext@bizec.recom MAPS and PLANS TO: paidr Wabizee.recom
♦ ENVIRONMENTAL ENGINEERING ♦ STORMWATER, WATER AND WASTEWXrER SYSTEMS
FEASIBILITY AND DEVELOPMENT CONSULTING ♦ GLOBAL POSITIONING SURVEYS+ SUBDIVISION AND CONSTRUCTION PLANS
� Compl eness Review Checklist
Project Name: lCr��-a-t'S.1� T-),
Project Location: N f.�L
Paperwork Emailed Engineer on:
Received Date: 4)15a' Z--3 �S
Accepted Date: Db ;yo 2J<5,
®Supplement(s) (1 original per BMP) BMP Type(s):
®O&M with correct/original signatures (1 original per BMP except LS/VFS and swales)
p ication with correct/original signatures El r Deed
®Corp or LLC: Sig. Auth. per SoS or letter ®Email Address
®$505 (within 6mo) ❑Email Address
Design Engineer
Owner
®Soils Report with SHWT Note to Reviewer:
®Calculations (signed/sealed)
®No obvious errors
®Density includes common areas, etc
Deed Restrictions, if subdivided:
Signed & Notarized
®Correct Template (Comm/Res & HD/LD) or Dec. Covenants & Rest.
Plans
ets
®Details (roads, cul-de-sacs, curbs, sidewalks, BMPs, Buildings, etc)
®Grading
®Wetlands: Delineated or No Wetlands
®Vicinity Map
®Layout (proposed BUA dimensions)
Legend
®DA Maps ❑Project Boundaries
Infiltration
Wet Pond
Offsite
Soils Report
MSoils Report
�PE Cert for Master Lot #:
SHWT:
®Deed Rest for Master ®Lot # Matches Master
Bottom:
®SHWT:
PP:
BUA Permitted (Master): sf
Visited:
BUA Proposed (Offsite): sf
Additional Information:
Permitted
Proposed: Proposed: Proposed:
BUA (sf)
DA (sf)
PP (el)
SHWT (el)
Depth (ft)
SA (sf)
Pusey, Steven
From: Pusey, Steven
Sent: Wednesday, July 22, 2015 2:29 PM
To: Jason Houston
Subject: RE: FW: Riverside Development SW8-081209
Jason,
I hope you are doing well. I am checking on the status of Riverside Development. What's the next step for
you at this point.
Thanks,
Steve
cf'/........ G. -P...A�y.
Environmental Engineer
Land Quality Section
Wilmington Regional Office
NC DF:Nli, Division ofEnergy
1 7 Cardinal Drive Ext.
\Vilmington, NC 28405
Mineral and Land Resources
Phone: 910- 7 J6-733-1.
Fax: 910-,150-1001,
\Vebsite: www.ncdenngov
E-Mail: stcven.pusey cr,ncdenr.gov
`B` Before printing this email, please consider your budget and the environment.
Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third,
parties unless the content is exempt by statute or other regulation.
From: Jason Houston [mailto:jhouston@bizec.rr.com]
Sent: Wednesday, November 12, 2014 11:19 AM
To: Pusey, Steven
Subject: Re: FW: Riverside Development SW8-081209
Attached is a PDF l was able to acquire that illustrates the Current drainage area for each pond.
Jason Houston, PE
Parker & Associates, Inc
Jacksonville NC, 26540
Firm License Number F-0108
910-455-2414 - Office
910-455-3441 - Fax
On 11/12/2014 10:40 AM, Pusey, Steven wrote:
FYI, just a reminder on this email. Please let me know when you find out details about the offsite area
to be handled in this permit.
Thanks,
Steve
From: Pusey, Steven
Sent: Friday, November 07, 2014 10:51 AM
To: 'Jason Houston'
Subject: RE: Riverside Development SW8-081209
Do you know whether your developer has to accept all offsite flow from Wrightsboro Plaza? Or, is it just
the outparcels such as Advance Auto? Previously, they were going to handle all. However, I don't know
the reason why for sure. I suspect that it was because the current swale and wetlands situation was not
working well. Your thoughts?
Steve
From: Jason Houston [mailto:ihouston@bizec.rr.comJ
Sent: Friday, November 07, 2014 10:37 AM
To: Pusey, Steven
Subject: Re: Riverside Development SW8-081209
Steven,
Here is our plan for Riverside. First I will submit the ownership change form information to
you. Next I will begin a redesign of the project. The Layout and road network, number of lots
etc... will not change. However I hopefully will be able to make substantial changes to the
drainage network and pond design to make this job more economically feasible.
In regards to OFFSITE stormwater. We will be required to accept the offsite flow from the
Zimmer property. FYI this property is landlocked and our only access is through the Zimmer
property. It appears that the original developer had to agree to some demands. These demands
are bound within a contract that our developer has agreed to, at least if he wishes to develop the
property. I have spoken with the developer this morning and he has told me to move forward. I
still must talk to the original Engineer and get all the information I need to do a redesign. But
that is our direction as of today.
Jason Houston, PE
Parker & Associates, Inc
Jacksonville NC, 28540
Firm License Number F-0108
910-455-2414 - Office
910-455-3441 - Fax
On 11/6/2014 11:13 AM, Pusey, Steven wrote
Jason,
How did your meeting go? Is the new developer willing to consider inclusion of the
built -upon area in Wrightsboro Plaza? Of course, this would require coordination with
Jeffrey Zimmer, the owner. I realize that they are not required by law to include this
area, however, it was planned previously. Please advise your thoughts.
Thanks,
Steve Pusey
DEMLR
From: Jason Houston[mailto:ihouston(albizec.rr.com]
Sent: Tuesday, November 04, 2014 5:24 PM
To: Pusey, Steven
Subject: Re: Riverside Development SW8-081209
Tomorrow Morning, Nov 5
Jason Houston, PE
Parker & Associates, Inc
Jacksonville NC, 28540
Firm License Number F-0106
910-455-2414 - Office
910-455-3441 - Fax
On 11/4/2014 4:18 PM, Pusey, Steven wrote:
Jason,
When is your meeting with New Hanover County to discuss this project?
Steve
From: Jason Houston [mailto:jhouston@bizec.rr.com]
Sent: Thursday, October 30, 2014 2:26 PM
To: Pusey, Steven
Cc: Scott, Georgette
Subject: Riverside Development SW8-081209
Steven, Georgette,
As I have already spoken to Mrs Scott about this project, this email
is just a quick follow up to let you know where I am currently. I
have a meeting next week with the New Hanover Planning
department to discuss the Riverside project. After the completion
of that meeting, we along with the owner will be collectively
deciding what the fate of this project will be. Our two options are
to one, continue as is with the project, at which point I will transfer
the permit to the new owners name. Beyond that, we may decide
to revisit the pond design with NCD) NR. As I have explained
before I feel that there is a potential cost savings with some
reworking of the pond design. The second option is to completely
redesign the project from start to finish. These answers depend
completely upon how well our meeting goes with the planning
department and what time frames and requirements they have. I
have never worked with New Hanover so this is new ground for
me. When a decision has been made 1 will contact you
accordingly.
Thanks..
Jason Houston, PE
Parker & Associates, Inc
Jacksonville NC, 28540
Firm License Number F-0108'
910-455-2414 - Office
910-455-3441 - Fax
Mrs Scott,
Here is the contact that 1 have made with the Zimmer Group.
C. Adam Tucker
Zimmer Development Company
111 Princess Street
Wilmington, NC 28401
910-763-4669 ext. 228 (p)
910-762-1999 (f
I have spoken to him twice on the phone. However, It wasn't
about stormwater, it was about sewer and their pump station
problems.
Jason Houston, PE
Parker & Associates, Inc
Jacksonville NC, 28540
Firm License Number F-0108
910-455-2414 - Office
910-455-3441 - Fax
4
Scott, Georgette
From: Scott, Georgette
Sent: Tuesday, July 07, 2015 8:07 AM
To: Pusey, Steven
Subject: FW: FW: Riverside Development SW8 081209
Steve,
You need to make sure you tell him what is needed when he returns. See below G
-----Original Message -----
From: Scott, Georgette
Sent: Tuesday, July 07, 2015 8:06 AM
To: 'pai-engineering@bizec.rr.com'
Subject: RE: FW: Riverside Development SW8 081209
Jason,
You will have to submit the application for the project when you return. I will hold the drawings to the side until your
return. But I can not process without the application and narrative.
Georgette
-----Original Message -----
From: pai-eneineerine@bizec.rr.com [mailto:pai-enaineerine@bizec.rr.com)
Sent: Thursday, July 02, 2015 3:48 PM
To: Scott, Georgette
Subject: Re: FW: Riverside Development SW8 081209
I have an email problem! My email program is broken and I've had to sift through hundreds of emails from the email
server (mostly junk),
What was sent was a plan modification. We are not changing the ponds or the BUA areas, the only real things we are
changing are how the pipes are run through the subdivision. I apologize if my submittal was vague, I had been talking
directly with Steven Pusey about what we were doing, and he was helping me gather the info I needed to finish this
project. I will be leaving today and heading on vacation so I will not be back until the week of the 13th. I will contact
you then, and hopefully be able to fix my email as well.
Sorry for the delay in response.
Jason Houston
---- "Scott wrote:
> Jason,
> Did you get this email.
> Georgette
> From: Scott, Georgette
> Sent: Tuesday, June 23, 2015 2:49 PM
Too p j IVA1
s�6 4zo,5�23
u'ri0s boro P19-2-4- ;'o .D tloA)
> To: Jason Houston (jhouston(@bizec.rr.com)
> Cc: Pusey, Steven
> Subject: Riverside Development SW8 081209
> Jason,
> We received two sets of plans from you for this development with no application materials or explanation on what the
changes are for this permit. According to Steve Pusey this is probably for a modification.
> Please provide the application, a narrative, $505.00 fee and appropriate supplements for the changes to the previous
plans for this permit. I will put these plans from you on hold till I receive the application materials.
> Georgette Scott
> Stormwater Program Supervisor
> State Stormwater Program
> NC Division of Energy, Mineral and Land Resources
> 127 Cardinal Drive Ext.
> Wilmington, NC 28405
> Phone (910) 796-7339
> Fax (910) 350-2004
> E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be
disclosed to third parties.
Scott, Georgette
From:
Scott, Georgette
Sent:
Tuesday, June 23, 2015 2:49 PM
To:
Jason Houston (jhouston@bizec.rr.com)
Cc:
Pusey, Steven
Subject:
Riverside Development SW8 081209
Jason,
We received two sets of plans from you for this development with no application materials or
explanation on what the changes are for this permit. According to Steve Pusey this is probably for
a modification.
Please provide the application, a narrative, $505.00 fee and appropriate supplements for the
changes to the previous plans for this permit. I will put these plans from you on hold till I receive
the application materials.
Gccn'gole Scow.
Slormwater Program Supervisor
Slalc Slornimiler Program
NC Division oL Energy, Mineral and Land Resources
127 Cardinal Drive Ext.
Wihuin}4on, NC 28,105
Plume (910) 796-7339
F,bx (910) 350-2004
F mail roncspondcnrc In and IFom this address may be subict.t w If Noth Carolina NuLli< 11CCofi15 Ln%' and Illy Lc disclosed to third panics.
PARKER & ASSOCIATES, INC.
Consulting Engineers - Land Surveyors - Land Planners
306 New Bridge Street • P.O. Box 976
Jacksonville, NC 28541-0976
(910)455-2414 • Fax:(910) 455-3441
www.pnrkerenginceiingandsurveying.com
Firm License Number F-0108
June 8, 2015
Mr. Steven Pusey
NCDENR-DEMLR
127 Cardinal Dive Extension
Wilmington, NC 28405
RE: Riverside Development
New Hanover County
SW Permit No.SW8-0 04 OQJ
Plan Revision 0? / 2 I
Dear Mr. Pusey:
Please find enclosed two copies of the Revised Plans for the above referenced project.
We are not proposing any BUA revisions, and we are not changing the ponds in any
manner. We are using the details of the ponds taken directly from the original permitted plans.
Please find enclosed two (2) copies of Plan Sheets: 2, 3, 5, 6, 7, 29, 30, and 31 of 31.
If you have any questions, please contact me.
iECEIVIE
JUN 2 2 2015
BY:
Enclosures
xc: Anthony W. Sydes (Letter Only)
CF (P), LAM
JAH/krp
CS.IAH.. P usey.RiversideDevelopment. Plan Revision.05.19.15
Sincerely,
PARKER & SSOC
Jaso A. Ho ston, PE
EMA IL ADDRESS: TEXT MESSAGF,S TO: n:dtext@bizee.recom MAI'S and PLANS TO: paidrafl@bizee.recn�m
♦ ENVIRONMENTAL ENGINEERING ♦ SPORMWATER, WXrER AND WASTEWATER SYSTEMS
♦ FEASIBILITY AND DEVELOPMENT CONSUIXING + GLOBAL POSITIONING SURVEYS ♦ SUBDIVISION AND CONSTRUCTION PLANS
Completeness Review Checklist
Project Name: �� Received Date:
Project Location: Accepted Date:
Rule(s) F-12008Za tal 1995 Coastal Phase II (WiRO.) EJ
Universal
Type of Permit: New o or R I Existing Permit # (Mod or PR): d / ZO-i
Density: HD or L Tvpe: ommercial or Residential I r,nirr_•
%: _�(% OK?) / I Stream
Subdivided?: SubdivisIon or Sinp
1 Map
RW Ma
2Z Z-q�(S
El1988 Coastal
to SW8
PE Cert on File?
Paperwork Emailed Engineer on:
MSupplement(s) ( original per BMP) BMP Type(s):
�O&M with correct/original signatures (1 original per BMP except LS/VFS and swoles)
Application with correct/original signatures Deed
Corp or L-C: Sig. Auth. per SoS or letter
Email Address: Design Engineer
[-1$505 (within 6mo) Email Address: Owner
❑Soils Report with SHWT } Note to Rev*ew/n�er:
Calculations (signed/sealed) `. t AFer..
�No obvious errors r S. " 6,, its 0 c
Density includes common areas, etc
�d Restrictions, if subdivided:
& Notarized
Plans
�2 Sets Details (roads, cul-de-sacs, curbs, sidewalks, BMPs, Buildings, etc)
Grading Wetlands: Delineated or No Wetlands
Vicinity Map Layout (proposed BUA dimensions)
Legend �DA Maps Project Boundaries
innitration
Wet Pond
Offsite
Soils Report
Soils Report
�PE Cert for Master Lot #:
SHWT:SHWT:
Deed Rest for Master Lot # Matches Master
Bottom:
PP:
BUA Permitted (Master): sf
Visited:
BUA Proposed (Offsite): sf
Permitted
BUA (sf)
DA (sf)
PP (el)
SHWT (el)
Depth (ft)
SA (sf)
Proposed;
Proposed:
Proposed: