Loading...
HomeMy WebLinkAboutSW8061006_HISTORICAL FILE_20070111STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 Q U kooU DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS 31 HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 2 d O"\ O t \ \ YYYYMMDD Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.F. Director Division of Water Quality January 11, 2007 Mr. H.G. Miller, Rector All Saints Church AMIA, Inc. 5058 Highway 70 West, Suite E4 Morehead City, NC 28557 Subject: Stormwater Permit No. SW8 061006 All Saints Episcopal Church High Density Development New Hanover County Dear Mr. Miller: The Wilmington Regional Office received a complete Stormwater Management Permit Application for All Saints Episcopal Church on November 28, 2006. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000. We are forwarding Permit No. SW8 061006, dated January 11, 2007, for the construction of the subject project. This permit shall be effective from the date of issuance until January 11, 2017, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within sixty (60) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact either Paul Bartlett or at (910) 796-7215. Sincer Edward Beck Regional Supervisor Surface Water Protection Section ENB/ptb: S:\WOS\STORMWATER\PERMIT\061006.janO7 cc: Susan H. Sayger, P.E., KSMJ, PLLC Katrina Marshall, Carteret County Building Inspections Paul T. Bartlett, P.E. Wilmington Regional Office Central Files o ` NhCarolma �1 atura//y North Carolina Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Phone (910) 796-7215 Customer Service Wilmington Regional Office Internet: w%wrewaterouality.ore Fax (910)350-2004 1-877-623-6748 An Equal OpportunirylAffnnative Action Employer — 50% Recyded110% Post Consumer Paper State Stormwater Management Systems Permit No.SW8 061006 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules and Regulations PERMISSION IS HEREBY GRANTED TO H. G. Miller & All Saints Church AMIA, Inc. All Saints Episcopal Church 290 McCabe Road, Newport — Carteret County FOR THE construction, operation and maintenance of 1 sand filter and an overall 30% low density development in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications, and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. The Permit shall be effective from the date of issuance until January 11, 2017 and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS Approved plans and specifications for projects covered by this permit are incorporated by reference and are enforceable parts of the permit. This project is overall low density with a designated pocket of high density. The low density areas are permitted for stormwater runoff treatment by sheet flow, and the runoff from the high density area is treated in a sand filter. The stormwater system to treat the runoff generated by the designated high density area has been approved for the management of stormwater runoff as described in Section 1.11 on page 3 of this permit. The system designated as Sand Filter 1 has been approved to treat a maximum of 47,916 square feet of built -upon area in Drainage Area 2. 4. The overall tract built -upon area percentage for the project must be maintained at 30% or less per the requirements of Section .1005 of the stormwater rules. The current permitted maximum amount of built -upon area for the entire project is 60,984 square feet (Drainage Areas 1 plus 2). This permit makes no allocation for any future built -upon area. 5. The low density areas of this project propose runoff treatment by sheet flow. Runoff conveyances, such as perimeter swales, must be vegetated with side slopes no steeper than 3:1 (H:V). 6. No piping shall be allowed in low density areas of this project except those minimum amounts necessary to direct runoff beneath an impervious surface such as a road or driveway to provide access. Page 2 of 8 State Stormwater Management Systems Permit No.SW8 061006 7. Projects covered by this permit in low density areas will maintain a minimum 30- foot wide vegetative buffer between all impervious areas and surface waters. 8. All roof drains for this project must terminate in the stormwater conveyance piping system to the permitted stormwater control system. 9. The runoff from all built -upon area within the designated high density area (approved Drainage Area 2 per Sheet #3) shall be directed to the permitted stormwater control system. 10. The sand filter must be operated with a 30' vegetated filter. 11. The following design elements have been permitted for sand filter system and must be provided in the system at all times. Units Sand Filter 1 a. Drainage Area Onsite Offsite ft2 68,389 68,389 0 b. Total Impervious Surfaces OS Buildings OS Streets OS Parking Sidewalks Offsite ft2 47,916 10,890 9,583 22,216 5,227 0 c. Design Storm inches 1.0 d. Sand Filter Depth feet 1.5 e. TSS Efficiency % 85 f. Filter Bottom Elevation FMSL 16.2 g. Filter Area @Bottom ft2 65.2 h. Sediment Area @Bottom ft2 65.2 i. Storage Volume W 3,844 j. Top of Sand FMSL 17.7 k. Filter Area @ Top of Sand ft2 905 I. Storage/Bypass Elevation FMSL 18.2 m. Controlling Orifice Diameter inches 6 n. Number of Orifices number 1 o. Receiving Stream Hull Creek p. River Basin White Oak q. Stream Index Number 21-15 r. Classification of Water Body '.C., II. SCHEDULE OF COMPLIANCE The stormwater management system, swales and other vegetated conveyances shall be constructed, vegetated and operational for their intended use prior to the construction of any built -upon surface. No homeowner/lot owner/developer shall fill in, alter, or pipe any drainage feature (such as swales) shown on the approved plans as part of the stormwater management system without submitting a revision to the permit and receiving approval from the Division. Page 3 of 8 State Stormwater Management Systems Permit No.SW8 061006 3. During construction, erosion shall be kept to a minimum and any eroded areas of the swales or other vegetated conveyances will be repaired immediately. 4. The permittee is responsible for verifying that the proposed built -upon area for the entire lot, including driveways and sidewalks, does not exceed the allowable built -upon area. Once the lot transfer is complete, the built -upon area may not be revised without approval from the Division of Water Quality, and responsibility for meeting the built -upon area limit is transferred to the individual property owner. 5. Prior transfer of the permit, the stormwater facilities will be inspected by DWQ personnel. The facility must be in compliance with all permit conditions. Any items not in compliance must be repaired or replaced to design condition prior to the transfer. Records of maintenance activities performed to date will be required. 6. The permittee shall at all times provide the operation and maintenance necessary to assure that all components of the permitted stormwater system function at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of side slopes. d. Immediate repair of eroded areas. e. Maintenance of side slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of structures, orifice, catch basins and piping. g. Access to all components of the system must be available at all times 7. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 8. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for each system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. 9. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction. 10. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to the approved plans, regardless of size. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area. e. Further subdivision, acquisition, or sale of all or part of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. Page 4 of 8 State Stormwater Management Systems Permit No.SW8 061006 11. The Director may determine that other revisions to the project should require a modification to the permit. 12. The permittee shall submit all information requested by the Director or his representative within the time frame specified in the written information request. 13. Access to the stormwater facilities shall be maintained via appropriate easements at all times. Stormwater conveyances will be located in either dedicated right-of-way (public or private), recorded common areas or recorded drainage easements. The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans. 14. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. Built upon area includes, but is not limited to, structures, asphalt, concrete, gravel, brick, stone, slate, coquina and parking areas, but does not include raised, open wood decking, or the water surface of swimming pools. 15. Unless specified elsewhere, permanent seeding requirements for the swales must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. III. GENERAL CONDITIONS 1. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division of Water Quality, in accordance with North Carolina General Statutes 143-215.6A to 143-215.6C. 2. The permit issued shall continue in force and effect until revoked or terminated. 3. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance, or termination does not stay any permit condition. 4. The issuance of this permit does not Prohibit the Director from reopening and modifying the permit, revoking and reissuing the permit, or terminating the permit as allowed by the laws, rules, and regulations contained in Title 15A of the North Carolina Administrative Code, Subchapter 2H.1000; and North Carolina General Statute 143-215.1 et. al. 5. The permit is not transferable to any person or entity except after notice to and approval by the Director. The Director may require modification or revocation and reissuance of the permit to change the name and incorporate such other requirements as may be necessary. A formal permit request must be submitted to the Division of Water Quality accompanied by the appropriate fee, documentation from both parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits, and may or may not be approved. 6. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the permit transfer request. Transfers to third parties by the permittee where the required documentation has not been submitted to the Division does not relieve the permittee of responsibility for transferring the permit. 7. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state and federal) which have Jurisdiction. If any of those permits result in revisions to the plans, a permit modification must be submitted. Page 5 of 8 State Stormwater Management Systems Permit No.SW8 061006 8. The permittee grants permission to DENR Staff to enter the property during business hours for the purposes of inspecting the stormwater management system and it's components. 9. The permittee shall notify the Division of Water Quality of any name, ownership or mailing address changes within 30 days. Permit issued this a 11th day of January 2007. NOR D1 CAROLINA EWMIRQNMENTAL MANAGEMENT COMMISSION forNdn—W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number SW8 061006 Page 6 of 8 State Stormwater Management Systems Permit No.SW8 061006 All Saints Episcopal Church Stormwater Permit No. SW8 061006 Carteret County Designer's Certification Page 1 of 2 I, , as a duly registered in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form are a part of this Certification. Noted deviations from approved plans and specifications: Signature Registration Number Date SEAL Page 7 of 8 State Stormwater Management Systems Permit No.SW8 061006 Certification Requirements: Page 2 of 2 1. The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built -upon area. 3. All the built -upon area associated with the project is graded such that the runoff drains to the system. 4. All roof drains are located such that the runoff is directed into the system. 5. The bypass structure elevations are per the approved plan. 6. The bypass structure is located per the approved plans. 7. All slopes are grassed with permanent vegetation. 8. Vegetated slopes are no steeper than 3:1. 9. The inlets are located per the approved plans and do not cause short- circuiting of the system. 10. The permitted amounts of surface area and/or volume have been provided. 11. All required design depths are provided. 12. All required parts of the system are provided. 13. The required system dimensions are provided per the approved plans. cc. NCDENR-DWQ Regional Office Katrina Marshall, Carteret County Inspections Page 8 of 8 _06 _&� �v D J orate or r4ortn Laronna Deportment of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may he photocopied for use as an original I. GENERAL INFORMATION 1. Applicants name (specify the name of the corporation, individual, etc. who owns the project): At- 5&'VrS CH-JrJCCW ^tA-LA =1JC 2. Print Owner/Signing Official's name and title (person legally responsible for facility and compliance): G. M tt_Lere (l7rCc�Q 3. Mailing Address for person listed in item 2 above: 5058 HiaNWAY city: Moiztsrr GAO C r%e State: N G Zip:—? 65S ¢ Telephone Number: ( L'32 ) 24 7 - 1.'DO!j 4. Project Name (subdivision, facility, or establishment name -should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): ALL S&AIJ S 17P13 CO( -,et. GN VrtGI4 5. Location of Project (street address): 290 MccAlser R.oAv City: N (: VdPO¢.r County: Ce¢rrratT 6. Directions to project (from nearest major intersection): 1+6A9ED CA3T Ot-t KIsAWAY 700 Iry 1?tV rate, 647 OtU rp MC"IsE ROAO, FpQ th Mt-e SOUr'V{ rve0 e14" on ry Pao10&ar-,r /S� i . 7. Latitude: L l•0 �• Lon itude: - -74 of project Orbt�sb(se/Elt,� `5o'ZZ' S. Contact person who can answer questions about the pro,(kct: Name: 15vSAti 11. pAYf Mo tic Telephone Number: (252 ) S49 5 03 it. PERMIT INFORMATION: 1. Specify whether project is (check one): New Renewal Modification Fonn SWU-101 Version 3.99 Page I of 4 1&10ro • 4y /t ,�. 2- 2. If this.application. is being subudttud as the result of a renewal or-modllitatian-ta-anexisting. permit, list the existing permitnutober.- _)gam_. _ and its issue date (if known) 3, Specify, the type of project (check one): ✓ Lo Density Nigh Density .--Redevelop Genr General Pemit.Other 4. Addit onal Project Requirements (check applicable btanks). CAMA Major _f Sedimentation/Erosion Control _404/401 Petttiit -_ NPDES Stormwater Information on required state permits can be obtained by contacting the Customer Service Center at 1-677-623-6748. ILL. PROJECT INFORMATION 1. In the space provided below, summarize how Auru water will by U01e.d. Also attach a detailed narrative (one to two pages) descrlbing stormwater management for the project. TH!S_i_I_, • s1.1a_ live • _2j_ A y ae- ewa - an -6 401'!! -R__.. FAcx .r T V rip P�cK�..JL. S.pf .+s�rc. t•07-LV Awt°�•'•"r' •fin lti �tyr er sS OpOcKir prsrt ppral• am s t•C.o p.�+rStr+: ALb f efty-ors weFAt" ryQArwi 1"O �h�et�r8 e�r.� NCI '---,"__-.- 2. Stormwater runoff from this in eject drairu to the N wY POR r &IR, w N t r f _ v A IC River basin. 3. Total Ptcrject Area:_:1—__acres 4. Project Built Upon Area:__,. _96 5, How many drainage areas does the project have?__ '4 r//I/a7 6. Complete the following Information for each drainage area. If there are more than two drainage areas in the project, attach an additional sheet with the Information for each area provided in the same format as below. 52 f r sea t--ir Basin Information Drainage Area 1 Drainage Area 2 Receiving Stream Name IIq SWAMP ea4ow� 1 Vt.�. SW^Hf. ee#& Receiving Stream Class G <=� Drainage Area 15Pe C46 3. (. ,A a teA (;� g 8 1. 5 7 Ace as Existing Impervious Area 13060 0. �j Agefu6 -®- $ Proposed Impervious'Area 1306p, O. 3 A e V es 47016 1. 1 4 t m s s %Impervious' Area (total) O %• L% Impervious Surface Area Drainage Area 1 Drdlrkzge Area 2 On -site Buildings 0 0890 0.2$ 4ee-4- On-site Streets 7g05 0.1 a 9503 O. EZ AS eer On -site Parking 5 bG3 O t t A c- 2221 b o. 5 1 e t CM On -site Sidewalks CP Z Z 7 cn t A C a t Other on -site 0 0 Ofr-site p O Total: 13065 D. 6 ,OG f.F 1 Total: Z171)(p 1. 1 adze - Impervious; area is denned as the built upon area including, but not limited to. buildings. roads, parking areas, sidewalks, gravel areas, etc. FonnSWU-101 Vefsion3.99 Page 2of4 ti 14: 2. If this application is being submitted as the result of a renewal or modification to an existing permit, list the existing permit number and its issue date (if known) 3. Specify the type of project (check one): low Density _High Density _Redevelop _General Permit _Other 4. Additional 1' 'ec[ Requirements (check applicable blanks): _CAMA Majo Sedimentation/Erosion Control Information on require , gate permits can be obtained by q 1-877-623-6748. Ill. PROJECT INFORMATION Permit _NPDES Stormwater the Customer Service Center at 1. In the space provided below, summarize flow stormwater will be treated. Also attach a detailed narrative (one to two pages) describing stormwater management for the project. 2. Stormwater runoff' 3. Total Project project drains to the 4. Project,Built Upon River basin. 5. How mangy/drainage areas does the project have? 6. Comp] t� the following information for each drainage area. If there are m\in wo drainage areas in the projeetgattach an additional sheet with the information for each area provisame format as below. Basin Information Drainage Area31 Drainage Area Receiving Stream Name U 6S W A, tAp 0 L. 5 M P Receiving Stream Class if Drainage Area 0.1N G S, A. G Existing Impervious' Area —�-- d Proposed Impervious"Area % Impervious" Area (total) p070 Impervious" Surface Area Drainage Area Drainage On -site Buildings On -site Streets On -site ParkingOn-site Sidewalks qea Other on -site Off -site Total: Total: " Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc. F� SWU-101 Version 3.99 Page 21f4 2p 0 7. How was the off -site impervious area listed above derived? #%) —A 1V. DEED RESTRICTIONS AND PROTECTIVE COVENANTS The following Italicized deed restrictions and protective covenants are required to be recorded for all subdivisions, outparcels and future development prior to the sale of any lot. If lot sizes vary significantly, a table listing each lot number, size and the allowable built -upon area for each lot must be provided as an attachment. 1. The following covenants are intended to ensure ongoing compliance with state stormwater management permit number as issued by the Division of Water Quality. These covenants may not be changed or deleted without the consent of the State. 2. No more than square feet of any lot shall be covered by structures or impervious materials. Impervious materials include asphalt, gravel, concrete, brick, stone, slate or similar material but do not include wood decking or the water surface of swimming pools. 3. Swales shall not be filled in, piped, or altered except as necessary to provide driveway crossings. 4. Built -upon area in excess of the permitted amount requires a state stormwater management permit modification prior to construction. 5. All permitted runoff from outparcels or future development shall be directed into the permitted stormwater control system. These connections to the stormwater control system shall be performed in a manner that maintains the integrity and performance of the system as permitted. By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the applicable items required above, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannotbe changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. V. SUPPLEMENT FORMS The applicable state stormwater management permit supplement form(s) listed below must be submitted for each BMP specified for this project. Contact the Stormwater and General Permits Unit at (919) 733-5083 for the status and availability of these forms. Form SWU-102 Wet Detention Basin Supplement V Form SWU-103 Infiltration Basin Supplement ✓ d Form SWU-104 Low Density Supplement ✓ Form SWU-105 Curb Outlet System Supplement Form SWU-106 Off -Site System Supplement Form SWU-107 Underground Infiltration Trench Supplement Form SWU-108 Neuse River Basin Supplement Form SWU-109 Innovative Best Management Practice Supplement Form SWU-101 Version 3.99 Page 3 of 4 1015106-bYAel/.4.4 VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ). A complete package includes all of the items listed below. The complete application package should be submitted to the appropriate DWQ Regional Office. 1. Please indicate that you have provided the following required information by initialing in the space provided next to each item. Initials Original and one copy of the Stormwater Management Permit Application Form s7 _ One copy of the applicable Supplement Form(s) for each BMP Permit application processing fee of $420 (payable to NCDENR) 99 Detailed narrative description isormwa[er treatment/management Two copies of plans and specifications, including: - Development/Project name✓ - Engineer and firm/ - Legend - - North arrow, - Scale / - Revision number & date i - Mean high water One , - Dimensioned property/project boundary - Location map with named streets or NCSR numbers - Original contours, proposed contours, spot elevations, finished floor elevations - Details of roads, drainage features, collection systems, and stormwater control measures - Wetlands delineated, or a note on plans that none exist •/ - Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations' - Drainage areas delineated - Vegetated buffers (where required) VIL AGENT AUTHORIZATION If you wish to designate authority to another individual or firm so that they may provide information on your behalf, please complete this section. Designated agent (individual or firm): 3USnN 14. 5^YG6R., 3�E.i KSM?y pile Mailing Address: '500 M e Q0rT&2 Fat.Vi2 City: State: lk3L zip: 25532 Phone: ( 25Z ) 0349- Sto 3 Fax: 445z ) 44'3- 5165 VBL APPLICANT'S CERTIFICATION 1, (print or type name of person listed in General Information, item 2) 1A.6. P'l l t—trF_ C certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of 15A NCAC 2H .1000. / i Date: 9• L O.OG Form SWU-101 Version 3.99 Page 4 of 4 KSMMpIIC.. Planning, Engineering, Permitting 388 McCotter Boulevard Havelock, NC 28532 252-444-5765 lielifforl Mr. Paul'f. Bartlett, PE NC DENR, Division of Water Quality 127 Cardinal Drive Ext. Wilmington, NC 28405 RE( NOV �• Re: Stormwater Project No. SW8 0 1006 All Saints Episcopal Church, C rot_ o -County Paul: Rp' EYVED v,., J 2 8 Z006 l�'a';5�g O�0/lif% Thanks for your patience and help with this project. We received your review and comment letter and have addressed each comment accordingly. ✓C`omment 1: Provide a 30' vegetated filter at the discharge from the sand filter outlet/bypass pipe, illustrate and label the 30' vegetated filter on the plans, and provide a detail. Response 1: The filter and detail was added to sheet 4. ,--Comment 2: Provide the bentonite liner for both the sediment and sand filter chambers and label specifications for thickness, compaction, and hydraulic conductivity on the detail on Sheet #4. Refer to 15A NCAC 21-1.0219(f) for design requirements Inatural materials 1' thick minimum & hydraulic conductivity no greater than 1 X 10 cm/sec when compacted). Response 2: The liner specifications were added to sheet 4. We feel this addresses your concerns and the stormwater management plan and permit can be approved. If you have any questions please call. Sincerel , 8 McCotter Blvd Havelock, NC 28532 252-444-ksmj(5765) FILE MODE -------------- 467 MEMORY TX P. 1 * COMMUNICATION RESULT REPORT ( NOV.16.2006 11:5BAM ) TTI NCDENR WIRO OPTION ADDRESS (GROUP) RESULT PAGE ------------------------------------------------ 7----------- ------------------ 912524445765 OK P. 3/3 REASON FOR ERROR E-1) HANG UP OR LI14E FAIL E-3) NO ANSI4ER adt4►/lt i, r E-2) BUSY E-4) NO FACSIMILE CONNECTION State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Michael F. Easley, Governor Date: 11 /16/06 To: Sue Sayger Company: KSMJ, pllc FAX #: (252) 444-5765 William G, Ross, Jr., Secretary FAX COVER SHEET No. of Pages: 3 (Incl. Cover) From: Paul Bartlett Water Quality Section - Stormwater FAX #: 910-350-2004 Phone #: 910-796-7301 DWQ Stormwater Project Number: SW8 061006 Project Name: All Saints Church MESSAGE: Sue, A Request for Additional Information is attached for the subject project. The original will be mailed to Rev. Miller, and a copy will be mailed to you. State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Michael F. Easley, Governor Date: 11 /16/06 To: Sue Sayger Company: KSMJ, pllc FAX #: (252) 444-5765 William G. Ross, Jr., Secretary FAX COVER SHEET No. of Pages: 3 (Incl. Cover) From: Paul Bartlett Water Quality Section - Stormwater FAX #: 910-350-2004 Phone #: 910-796-7301 DWQ Stormwater Project Number: SW8 061006 Project Name: All Saints Church MESSAGE: Sue, A Request for Additional Information is attached for the subject project. The original will be mailed to Rev. Miller, and a copy will be mailed to you. i4 ENB\ptb: S:\WQS\STORMWATER\ADDINFO\2006\061006.nov06 127 Cardinal Drive Extension, Wilmington, NC 28405-3845 Telephone (910) 796-7215 FAX (910) 350-2004 An Equal Opportunity Affirmative Action Employer Michael 1'. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality November 16, 2006 Reverend H.G. Miller, Rector All Saints Church AMIA, Inc. 5058 Highway 70 West, Suite E4 Morehead City, NC 28557 Subject: Request for Additional Information Stormwater Project No. SW8 061006 All Saints Episcopal Church Carteret County Dear Reverend Miller: The Wilmington Regional Office received a Stormwater Management Permit Application for All Saints Episcopal Church on October 10, 2006, and a revised application on November 2, 2006. A preliminary review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: Please provide a 30' vegetated filter at the discharge from the sand filter outlet/bypass pipe, illustrate and label the 30' vegetated filter on the plans, and provide a detail. Please provide the bentonite liner for both the sediment and sand filter chambers and label specifications for thickness, compaction, and hydraulic conductivity on the detail on Sheet #4. Refer to 15A NCAC 2H.0219(f) for design requirements (natural materials 1' thick minimum & hydraulic conductivity no greater than 1 X 10-6 cm/sec when compacted). Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to November 28, 2006, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you need additional time to submit the information, please mail or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter. The request must indicate the date by which you expect to submit the required information. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. No jlathCarolma turally North Carolina Division of Water Quality 127 Cardinal [hive Extension Wilmington, NC 28405 Phone (910) 796-7215 Customer Service Wilmington Regional Office Internet: www.ncwatcrqualitv.org Fax (910)350-2004 1-877-623-6749 An Equal OpportunitylAffinative Action Employer- 50% Recycled110% Post Consumer Paper Reverend H.G. Miller November 16, 2006 Stormwater Application No. SW8 061006 Please reference the State assigned project number on all correspondence. Any original documents that need to be revised have been sent to the engineer or agent. All original documents must be returned or new originals must be provided. Copies are not acceptable. If you have any questions concerning this matter please feel free to call me at (910) 796-7301. Since ly, / 9�j _� �. Paul T. Bartlett, P.E. Environmental Engineer ENB/ptb: S:\WQS\STORMWATER\ADDINFO\2006\061006.nov06 cc: Susan H. Sayger, KSMJ, pllc Paul Bartlett KSM�pIJ�., Planning, Engineering, Permitting 388 McCotter Boulevard Havelock, NC 28532 252-444-5765 RECEIVED 10-25-06 NOV 0 2 20 6 Mr. Paul T. Bartlett, PE� NC DENR, Division of Water Quality 127 Cardinal Drive Ext. Wilmington, NC 28405 Re: Stormwater Project No. SW8 Unassigned# All Saints Episcopal Church, Carteret County Paul: Thanks for your patience and help with this project. We received your review and comment letter and have addressed each comment accordingly. Khesite nt 1: Please clarify the longitude and latitude in Section 1.7 of the application. appears to be closer to 34°44'32" N and-76°50'22"W. Response I: The application has been revised to this latitude and longitude. Topo map of with latitude and longitude is included for verification. Comment 2: Provide 2 copies of Sheet #2 with a signed and dated Registered Surveyor's `, or 1'I stamp. Response.2. 2 copies of Sheet 2, with the Registered Surveyor, are included. Comment 3: Clearly illustrate: (a) the limits of disturbance on Sheets #3 and #4, including a symbol in the legend; and (b) the drainage areas (hand -marked Sheets #2 - #4 will suffice. Response 3: ,Sheet 5 has been revised to increase the clarity of limits of disturbance. A legend was added depicting limits of disturbance is on Sheet 5. The drainage areas are shown on Sheets 3, 4, and 5. mment 4: Provide a copy of the soil consultants report for soil type, infiltration rate, r/ and SHWT at all test locations. Response 4: Copy of soils report is included. KSM�pII�, Planning, Engineering, Permitting 388 McCotter Boulevard Havelock, NC 28532 252-444-5765 omment 5: Clarify the basin's drainage area. The calculations list 1.1 ac and the plans Response 5: The basin's drainage area is 1.5 acres. The revised, sealed calculations are included in this submission package. Comment 6: Provide: (a) a bypass for the basin for runoff that exceeds the 1" design OFr storm; and (b) a detail of the bypass structure, including invert elevations. Response 6: The basin by-pass is a .section of ertical 6" pvc, wit invert in at 19.4. �ai/� can befiound on Sheet 4.21�v� Uve%F(a f'� p. iz IJeY a.K (.cd tki( I,,-- ((c. dL f e t .a r t Q 41- t t(s ✓ 5 ,womment 7: provide a cross-section detail of the basin. 1 recommend that the proposed eir be removed to configure the system as an infiltration basin with a bottom elevation VVVVVV of 17' (approx. 29" W X 66' L) using the proposed contours and 3:1 side slopes. Storage requirements are met at approximately 18.6' (see attached calculations). Response 7: A cross section of the basin was provided in the profile, with 3:1 side slopes. For clarity, we have included a cross section at a larger scale. The basin is submitted as a .sand filter, requiring the weir. Comment 8: Provide PE -stamped calculations incorporating the above revisions, vincluding a stage -storage table with surface areas and accumulated volumes. Response 8: PE stamped calculations with above revisions, including stage -storage table, are included with the submission package. We feel this addresses your concerns and the stormwater management plan and permit can be approved. If you have any questions please call. S�niincerely, �OO mfu ✓.,...>� ✓e� ✓lam, 388 McCotter Blvd Havelock, NC 28532 252-444-ksmj(5765) 1; McCabe Road Town of Morehead City, North Carolina Stormwater Narrative -Sand Filter .gnAaawGoa This stormwater narrative discusses the stormwater management design and permit application for the construction of a stormwater management sand filter with sedimentation basin to serve a new, slab on -grade, church facility, All Saints Episcopal Church. The church will be located on an 11.9-arce parcel, in the Town of Morehead City, Carteret County (one of NC DNER's coastal counties). Zoned residential (church facility is a permitted use), the parcel fronts McCabe Road (south of NC Highway 70) and borders on 1-lull Swamp Creek which ultimately drains into the White Oak River. Hull Swamp Creek is classified as a C class water. There are no applicable AECs associated with the parcel. No disturbance, grading or construction will take place within 240 feet of the creek. We see no applicable CAMA issues. There are no CAMA jurisdictional wetlands within the scope of this project, per discussions with and provided documentation from Land Management Group. �l�t!oaddw" Currently, the existing topography of the entire parcel is flat, with the majority of the parcel draining westerly across a minimum grade (less than one percent). For over 90% of the site, these existing drainage divides are honored, including the two existing ditch lines. These ditch lines will continue to act as vegetative filters for the parcel, including the 0.3 acres of existing impervious surfaces, which will remain. As seen in the attached calculations, the pre-existing run-off from the site for the 2-year and 10- year event are 12.8 and 34.1 cfs, respectively. �Londa4ana Although the project meets the requirements for low density of less than 30%, with only 1.1 Acres of impervious surface out of the total 11.9 Acres, or 9.2%, we respectfully submitted this sand filter with sedimentation basin, providing for a pocket of high density. This method of storage was mandated by site conditions, particularly the complete lack of topographical relief on the site and high water table. The percentage of proposed imperviousness, includes building area (10,890 sq ft) and paved and sidewalk area (37,026 sq ft). All impervious surfaces will drain through roof drains and catch basins into culverts and into the two -chamber, sand filter basin. Run-off will first settle and flow through the pre-treatment, sediment chamber. The sediment chamber meets the depth (16.2-17.7, 1.5 feet), volume (1276 t, ' ,W,5 .& f 6--d McCabe Road Town of Morehead City, North Carolina Stormwater Narrative -Sand Filter cu ft, 810 required) and surface area (905 sq ft, 540 cu ft required) requirements. From the sediment chamber, run-off will flow over the weir into the sand filter chamber, which includes 18 inches of sand, surrounded by an impervious, bentonite clay liner and filter fabric. In the center is a filter fabric -wrapped, 85' section of perforated 6" pvc for drainage. The sand filter chamber meets the depth (16.2-17.7, 1.5 feet), volume (1276 cu ft, 810 required) and surface area (905 sq ft, 540 cu ft required) requirements. The 1-inch storm is completely contained between the top of the sand and by-pass invert, allowing the 1-inch event to drain through the sand filter in 7.09 hours. Events greater than the 1-inch will by-pass the filter, with 0.6-fect of freeboard. Without the basin, the post -development run-off from the site for the 2-year and 10- year event are 16.5 and 40.8 cfs, respectively. With the basin, the post -development run-off from the site for the 2-year and 10- year event are 12.96 and 33.86 cfs, respectively. The velocity for the 2- year event is not at an erosive levels, however, the rip -rap from the check dam will be left in place to minimize the potential for erosion in the existing channel. ' .w. The proposed design includes only 1.1 Acres of impervious surface out of the total 11.9 Acres, or 9.2%. In addition to the existing vegetative swales which will remain and provide filtering, we have provided stormwater management to mitigate the additional imperviousness through a two -chamber sand filter basin, containing the required event, with freeboard, meeting or exceeding all DNER size and depth requirements. Susan H. Sayger,PE KSMJ,pllc 388 McCotter Blvd Havelock, NC 28532 252-349-5803 252-444-5765 `\\\o�unuiinuunq �ss �eQeG �t , 3Ltik4� N 1{ 2 October 19, 2006 Wes McClure MCCLURE HOPKINS ARCHITECTS 1848 Wake Forest Road Raleigh, NC 27608 Re: Report of Subsurface Investigation All Saints Episcopal Church Morehead, North Carolina GeoTechnologies Project No. 1-06-1 175-EA Gentlemen: 3200 Wellington Cour, Suite G Roleigh. North Caiolino 27615 919-754-1514 Fax 919-754-1428 NOV 0 2 2006 GeoTechnologics, Inc. has completed the authorized subsurface investigation to evaluate site grading and foundation support considerations for a proposed new church to be constructed in Morehead City, North Carolina. Subsurface conditions at the site were investigated by advancing seven soil test borings at the approximate locations shown on the attached Figure 1. The locations were established in the field by estimating distances from existing site features and should therefore be considered as approximate. The proposed locations were provided by the architect. Test boring B-4 was eliminated, and test boring B-3 and B-5 were extended to 40 feet below site grade due to site conditions encountered. All of the remaining borings were terminated at 15 feet below site grade. All borings were advanced utilizing standard penetration test procedures at selected intervals to evaluate the consistency and density of the subsurface soils. This report presents the findings of our investigation and our recommendations for site grading and foundation support. SITE AND PROJECT INFORMATION It is our understanding that the new construction of the proposed All Saints Episcopal Church will include a single story worship space with a support wing with finish floor elevations of 20.5 feet. The site is approximately 12 acres and located on Hwy-70 west of Morehead City, Carteret County, North Carolina. The site is relatively flat, and no development currently exists in the proposed building area. No detailed information concerning structural loads was available at this time; however, we anticipate the structure will be supported on a combination of interior columns and exterior load bearing walls. We anticipate the proposed building will be surrounded by asphalt paved parking and drive areas. SUBSURFACE CONDITIONS A generalized subsurface profile prepared from the test boring data is attached to this report as Figure 2 to graphically illustrate subsurface conditions encountered at this site. More detailed descriptions of the conditions encountered at the individual test boring locations are thenapresented on the attached test boring records. 9eotechnicol and Construction Motorials resting Services McClure Hopkins Architects All Saints Episcopal Church October 19, 2006 Page: 2 Subsurface conditions on the site were characterized by the presence of a surface veneer of topsoil extending approximately 8 to 10 inches below site grade. The topsoil was underlain by silty and clayey sands to the boring termination depth. Test borings B-3 and B-5 were extended to 40 feet below existing site grade. All other borings were terminated at 15 feet below site grade. Penetration resistances in the silty sands were on the order of 1 to 15 blows per foot (bpO above an elevation of 36 feet. Materials below a depth of 36 feet below site grade resulted in resistances of 50 blows per 4 inches of penetration at B-3 and 77 bpfat 13-5. Groundwater was encountered at approximately 2.5 feet below site grade. It should be noted that temporary pert ed water conditions may occur during inclement weather and regional groundwater levels will fluctuate with seasonal and climatic changes and will be different at other times. RECOMMENDATIONS The following recommendations are made based upon a review of the attached test boring data, our understanding of the proposed construction, and past experience with similar projects and subsurface conditions. Should site grading or structural plans change significantly from those now under consideration. we would appreciate being provided with that information so that these recommendations may be confirmed, extended, or modified as necessary. Additionally, should subsurface conditions adverse to those indicated by this report be encountered during construction, those differences should be reported to its for review and comment. Suitability of Site. Subsurface conditions on the site are suitable for the proposed construction; however, due to the presence of very loose sands encountered in the upper 35 feet, special considerations may be required to prevent excessive settlements, depending on actual structural loads which are not currently known. This could include pile support if column loads warrant, or undercut and stone replacement which will also require dewatering. We anticipate the most suitable type of foundation system would be driven timber or concrete piles. Timber piles driven to depths of 35 to 40 feet below site grade could achieve allowable capacities of 20 tons per pile. Twelve (12) inch square concrete piles driven to the same depth could achieve allowable capacities of 50 tons. Additionally, the ground surface will be very unstable and may require importing some granular fill materials and raising elevations to stabilize subgrades. Site Grading Considerations. Site grading should initially begin with removal of any vegetation or topsoil from the areas which will be developed with the new structure and/or paved areas. Due to the shallow groundwater table encountered, it may be necessary to raise grade on the project to create a platform for construction. The exposed subgrades will be very unstable, and fill materials will need to be placed in a 24 inch lift consisting of a clean sand followed by compaction with a vibratory roller. Additional lilts can then be placed in typical 8 to 12 inch lifts. Raising grade in this manner should create a platform for the construction operation and stable pavement subgrades. If undercut and stone replacement is used, we anticipate neat line cuts of up to 5 feet will be necessary in some areas. This will require aggressive dewatering, probably with closely spaced well points. �t GeoTedinologies,lnc. McClure Hopkins Architects All Saints Episcopal Church October 19, 2006 Page: 3 If'off-site borrow will be imported, we recommend importing a clean to silty or clayey sand with Unified soil classifications of SP, SM or SC as structural fill. Granular material containing fines less than 10% passing a 9200 sieve will be necessary to obtain compaction if placed in a 20 to 24 inch lift. All new fill should be compacted to not less than 95% of the standard Proctor maximum dry density except in the final foot beneath pavements and floor slabs where this requirement should be increased to 98% of the standard Proctor maximum. Shallow Foundation Considerations. Existing subsurface conditions on the site are not well suited to the use of shallow spread lootings due to the presence of loose sands and settlement potential. We estimated settlements of shallow footings using the FILA procedure that correlates soil compressibility to soil type and N-value. Figure 3 shows the estimated settlement of column footings embedded 2 feet below grade and sized for 3,000 psf bearing pressure plotted versus column load and Figure 5 shows estimated settlements for a bearing pressure of 2000 psf. We estimate footings supporting 100 kip column loads with a contact stress of 3000 psf will settle more than 1.5 inches In our experience, the diflerential settlements will be approximately half the maximum settlements. Some stone replacement techniques can be implemented to reduce settlements to within acceptable limits. Included on Figures 3 and 4 are estimated settlements utilizing 4 feet of washed stone under the foundations to reduce total settlements. Due to shallow groundwater and loose sands, over -excavation of foundations will be extremely difficult and we recommend several test pits be conducted on the site to allow the contractor to best determine means and methods for excavation of foundations. Dewatering with closely spaced well points will likely be required. We recommend that bearing conditions for shallow footings be inspected by a geotechnical engineer to verify actual bearing conditions prior to stone placement. We recommend that over -excavated footings be backtilled to design bearing elevation utilizing uniformly graded #57 or #67 washed stone. Pile Foundation Support. If the estimated settlements for shallow foundations are considered excessive by the structural engineer, we recommend that the structure be supported on pile foundations. In order to evaluate potential capacities, a static analysis was performed for an 8 inch timber pile. Figure 5 shows plots of the ultimate skin friction and total load plotted vs. depth in feet for timber piles. Timber piles with a design capacity of 20 tons would need to penetrate to a depth of 36 to 42 feet below existing site grade. Figure 6 plots capacities vs. depth for concrete piles. If concrete piles are used, we suggest that they be driven with a hammer having a minimum rated energy of not less than 19,500 ft. lbs. until achieving a dynamic set indicative of the design capacity based on either the old North Carolina State Building Code formula or the fiiley equation. Two alternatives are possible for evaluating the in -place capacity of the piles. Full scale pile load tests can be performed but will be quite expensive due to the requirements for developing uplift capacity on the reaction piles at the site. Another alternative would be to utilize a pile driving analyzer (PDA) to evaluate the apparent safe design working load for the piles. If timber piles are used, we suggest that they be driven with a hammer having a minimum rated energy of 15,000 ft. lbs. until achieving a dynamic set corresponding to the desired design capacity. Timber piles would not require load testing since they have a design capacity of less than 40 tons. It is recommended that several penetration test piles be driven at the start of construction in order to establish pile driving criteria and to better evaluate the required length of piling before the order is placed for the remaining production piles. We suggest obtaining overlength piles then driving with a hammer selected for the project until achieving a dynamic set indicative of the design capacity based on the old State Building Code. In the case of concrete piles, a PDA should be mobilized to the site to perform restrikes afler a minimum waiting period of 72 hours. The PDA can then be used to confirm the design McClure Hopkins Architects All Saints Episcopal Church October 19, 2006 Page: 4 working load, establish final driving criteria, and the penetration test pile data can be used by the contractor to then place a production pile order. It should be recognized that the actual required pile lengths may be different from those calculated using static equations, and actual lengths may be longer or shorter than the estimated lengths. Slab -on -Grades. Provided granular material is imported to the site, the near surface soils will then provide adequate support for lightly loaded slab -on -grades. Even if the structural loads are supported on driven piles, we do not anticipate the need for a structural slab. Assuming that at least 24 inches of compacted granular structural fill is placed over the site, the slab can be designed assuming a subgrade modulus of 100 pci. General Pavement Design Considerations. No detailed laboratory testing was completed to enable as to perform a final pavement design. The subgrades following topsoil removal will not be stable due to the shallow groundwater and loose sands on the site. As previously discussed, if elevations of the site are raised during the earthwork operation, CBR values will be dependent or the quality of the imported rill material. Regardless, the exposed subgrades will have to be proofrolled to determine if subgrade stability will be adequate for pavement sections. In order to achieve stability in parking areas, some geotextiles will likely be necessary for subgrade improvement. The most important factors affecting pavement life in the area of the site are the condition of the subgrade immediately prior to base course stone placement and post -construction drainage. It is important that site grades be detailed to promote positive drainage away from paved areas and that all subgrades be recompacted to 98% of the standard Proctor maximum dry density immediately prior to base course stone placement. As previously discussed, we recommend that the subgrades of all paved areas be proofrolled and that any yielding areas be identified and repaired during the initial grading operations. We recommend that all pavement areas be properly graded to promote runoff of water and to prevent ponding of water on the pavement surface which will lead to eventual saturation of subgrade soils and potential loss of pavement support. Seismic Design Considerations. The potential for liquefaction of the very loose clean sands encountered in several layers in the site soil profile indicate that the site should be classified as a seismic site class "I" according to the North Carolina Building Code. The measured response spectra for sites that have actually liquefied which are reported in the literature, have been less than the IBC class "E" response spectra at periods of one second or less. Therefore, the class "E" response spectra provides a maximum surface ground motion for structural design of two story structures, which have natural periods well less than one second, and the risks associated with liquefaction should be treated separately. This site's liquefiable sands start at the ground surface and extend to 40 foot below existing ground surface. Liquefaction will result in estimated post -earthquake settlements on the order of 10 inches but will likely not cause a total bearing capacity failure. Therefore, liquefaction of the loose sands caused by the design earthquake event will likely result in significant structural damage, but without any loss of life. The owner will need to weigh the cost of soil improvement required to reduce liquefaction risks with the risk of the IBC design earthquake occurring, which has a reoccurrence interval on the order of 2,500 years. The risks associated with the design earthquake events include the cost of significant repairs with the potential for replacement. 01: GeoTe(iliologies, Int. McClure Hopkins Architects All Saints Episcopal Church October 19, 2006 Page: 5 Several different soil improvement techniques have been used on similar sites to mitigate liquefaction concerns. The various techniques include densification methods such as vibrocompaction, vibroreplacement, deep dynamic compaction, and compaction grouting; hardening techniques such as soil mixing and grouting, or the installation of earthquake drains. Some of the available techniques may be more feasible than others for this specific case, but the choice will also depend on what type of foundation system is considered. No matter what soil improvement method is selected, the general geotechnical recommendations presented in this report will need to be reviewed by a specialty contractor. If consideration will still be given to proceeding with construction on the site, GeoTechnologics would be happy to recommend subcontractors for the different soil improvement techniques. GeoTechnologics, Inc. appreciates the opportunity to be of service on this phase of the project. please contact us if you have any questions concerning this letter or if we may be of additional service on this or other projects. Sincerely, GcoTechnologies, Inc. � 'Roby Mallik, E. NC Registration No. 264 TM/pr-dli/lam Attachments 061175ca.dou l GeoTechnologies, Inc: i L!1 ,S 0E1FT + T ! f ! ! I ,9 502-,5' -01 All Saints Episcopal Church Newport, North Carolina fm VIM -15, INV ER t SCALE: Not to Scale JOB No: 1-06-1175-EA FIGURE No: 1 C7[ GT.:4�L Depth (Feet) GENERALIZED SUBSURFACE PROFILE B- 1 B- 2 13-{3 B- 5 B- 6 B- 7 P-1 A o 6 3 �] J 2 �% 3 L%FIII 3 Q 3 7 5 15 3 15 12 6 15 N=1 7 11 13 7 10 2 9 10 6 6 6 r 8 3 7 15 8 7 4 7 14 6 1 20 IrMl 5 IEI11 4 1 25 IN111 1 It111 3 1 30 Mil 2 IFI11 7 1 35 IN11 9 I[I11 7 40 IM 5014" LEW 77 45 All Saints Episcopal Church =Mrf MOM I JOB No:1-06-1175-EA Newport, North Carolina FIGURE No:2 LEGEND ■ Topsoil Silty Sand Partially Weathered Rock ® Low Plasticity Clay 8 Standard Penetration Resistance ❑N=8 Estimated Penetration Resistance Q Groundwater at Time of Boring 1 Groundwater after Time of Boring //xw' Auger Refusal c 2 1.8 1.6 1.4 1.2 0I 0.6 0.4 0.2 0 ESTIMATED SETTLEMENT vs COLUMN LOAD FOR INDICATED BORING LOCATIONS R stone lent 0 50 100 150 200 250 300 350 Column Loads(kips) FIGURE 3 Assumes 3000 psf contact stress I 1 1 '1 H 91 ESTIMATED SETTLEMENT vs COLUMN LOAD FOR INDICATED BORING LOCATIONS i ) i 6 B-3 —4111— 8-3 & 4 ft stone replacement ..v ivv VV GVV GJV Column Loads(kips) FIGURE 4 Assumes 2000 psf contact stress M 60 50 40 PAl iD Ultimate Capacity for 8" inch Tip Timber Piles All Saints Chuch ^�b - Ult -UIt. Friction B-3 _ Total B-3 1 a d d _... A —° ♦ �d rr ° d° ♦ - — .'— --...r.r.. a 4r4 c Lr• •trtrtrtrl AIC 10 20 30 40 50 Depth(R) Divide ultimate capacities by factor of safety of 2 to determine allowable capacity. Figure 5 1-06-1175-EA 10/20/2006 Ultimate Capacity for 12" inch Square Concrete Piles All Saints Church 140 130 120 110 100 90 N c 80 _T A 70 6 A u 60 50 40 30 20 10 0 0 10 20 30 40 50 60 Depth(ft) Divide ultimate capacities by factor of safety of 2 to determine allowable capacity. Figure 6 1-06-1175-EA 10/20/2006 U.S. Standard Sieve Sizes +^ E/ C10 s20 i40 060 #100 4200 10o 90 80 70 60 60 ♦0 00 20 10 0 100 e s 4 2 10 a e a 2 1 e e 4 2 3.1 e 6 < 2 0.01 e c a 2 0.001 e e Grain Size In Millimeters GRAVEL SAND FINES COARSE I FINE I COARSE I MEDIUM I FINE SILT SIZES I CLAY SIZES Boring No. Elev./Depth Nat W.C. LL. P.L. P.I. GRAIN SIZE DISTRIBUTION \.... S Grey Slightly Silty Fine Sand Proiect: Job No.: All Saints Episcopal Church Morehead City, North Carolina Date: 10/11/06 DEPTH (FT.) 0.0 0.8 6.0 15.0 TEST BORING RECORD DESCRIPTION ELEVATION PENETRATION BLOWS PER (FT.) (BLOWS/FT.) SIX INCHES O lO 20 aO 60 1OO Topsoil 2-3-3 1-7-8 4-" 333 5--4-4 t Medium Dense Light Gray Silty Fine SAND SM Loose Gray Silty Fine to Medium SAND SM Boring terminated at 15' Groundwater encountered at 2' alter 24 hours. JOBNUMBER 1-06-1175-EA BORING NUMBER B- I DATE 9-20-06 PAGE 1 OF I GcoTechnologies, lnc. DEPTH DESCRIPTION (FT.) n.a 0.7 15.0 TEST BORING RECORD ELEVATION PENETRATION BLOWS PER (FT.) (BLOWSIFT.) SIB INCHES 0 10 20 40 60 100 'IU Soll SM I I I 2-1-2 I-1-2 6-6-5 3-3-3 I-4-3 Q Lowe Gray Silty fine to Medium SAND Boring terminated or IS' I Groundwater encountered at 3' at time of boring. JOB NUMBER BORING NUMBER DATE PAGE I OF I 1-06-1175-EA \ „ B- 2 9-20-06 DEPTH (FT.) 0.0 0.7 36.0 40.0 40.5 TEST BORING RECORD DESCRIPTION ELEVATION PENETRATION BLOWSPER (FT.) (BLOWS/FT.) SIX INCHES 0 10 20 40 60 100 Topsoil SM I 1-I-I 1=12"-3 4-2-5 3-2-4 1-2-2 3-3-2 2-1=12" 1-4-s 29-46-50/4" Q Loose Gray Clayey Silty Fine to Medium SAND Very Dense Gray Silly Fine to Medium SAND SM Naniall Weathered Rock - No Rccove Boring terminated at 40.5' Groundwater encountered at 3' at time of boring. JOB NUMBER BORING NUMBER DATE PAGE I OF I 1-06-1 175-EA \ B- 3 9-21-06 a DEPTH (FT.) 0.0 0.7 3.5 6.0 36.0 40.0 TEST BORING RECORD DESCRIPTION ELEVATION PENETRATION BLOWS PER (FT.) (BLOWSIFT.) SIX INCHES n In 711 do 6n 1M - 1-I-2 3-7-8 4-4-6 2-3-5 3-4-3 2-2-2 2-1-2 1-1-1 4-34 32-43-34 V Loose Gray Silty line SAND SM Medium Dense Light Brown Gray Silty Fine SAND SM Loose Gray Silty Fine to Medium SAND SM Very Dense Gray Silty Fine to Medium SAND SM Boring terminated tit 40' vrounowater encountered at L.Y at time of boring. ,JOB NUMBER BORING NUMBER DATE PAGE I OF I 1-06•II75-EA B- 5 9-20-06 J DEPTH (Fr.) 0.0 0. kl 6. TEST BORING RECORD DESCRIPTION ELEVATION PENETRATION BLOWS PER (FT.) (BLOWS/FT.) SIX INCHES 8 To soil — +v vv .vu 2-34 578 i i i i e t Y Loose Yellow &own Slightly Clayey Silty Pine to Medium SAND SM Medium Dense Gory Silly Pine Io Medium SAND SM Haring terminated at 6' JOB NUMBER BORING NUMBER DATE PAGE I OF I u, .v a. wuc ut vunug. 1-06-1175-EA P-IA 9-21-06 GeoTechnologies, Inc. DEPTH (FT.) 0.0 0.. 15.c TEST BORING RECORD DESCRIPTION ELEVATION PENETRATION BLOWS PER (FT.) (BLOWS/FT.)SIX INCHES n In in An <n Inn 9 Topsoil Loose Gray Silty Fine SAND SM 1.2-I Q 3-3-5 44-5 2A-3 I L3oring temtinatcd at IS' 4-3-3 v1VUnUw41c1 ntunuactcu at G.T at time Or oormg. JOB NUMBER BORING NUMBER DATE PAGE I OF I 1-06-1175-EA B- 7 9-20-06 1 1 v1VUnUw41c1 ntunuactcu at G.T at time Or oormg. JOB NUMBER BORING NUMBER DATE PAGE I OF I 1-06-1175-EA B- 7 9-20-06 1 1 DEPTH (FT-) 0.0 0.8 2.: 6.1 6.: TEST BORING RECORD DESCRIPTION ELEVATION PENETRATION BLOWS PER (FT.) (BLOWS/FT.) SIX INCHES n In 9n An cn Inn Topsoil -- -- - -- - 1-I-2 5-6-6 N-1 1-1-I I-I-2 2-6-8 Q - Black Loose Silty Fine to Medium SAND SM Medium Dense Yellowish Gray Silty Fine to Medium SAND SM Soft Light Yellow Gray time Sandv Siltv CLAY G SM Very Loose Gray Silty Pine to Medium SAND L 17ib Medium Dense Gray Silty Fine to Medium SAND SM noting lerminated at 15, urotmuwaier encountered at 2.�, at time of boring. JOB NUMBER BORING NUMBER DATE PAGE I OF I 1-06-1 175-EA B- 6 ... : 9-20-06 _ o ALL SAINTS EPISCOPAL CHURCH 9120/2",,rmad 102S-W OEnmr olooks inAws, vp(�L KSMJ,plle 388 McCotter Blvd, Havelock, NC 28532 Design Requirments sediment chamber 11.9 total sae (aces) 1.5 drainage acre (aCla3) 1.1 InpeMousrresa (ace) 0,092436975 % of site arpervioua 47916 imperviousness, SO FT 810 cf voltme Md(540Cf/dr area 540 surface area 360sMaca 15 depth sandfdter 11.9 1.5 drainage ace (aces) 0.092436975 % of site impeMous 1.1 imperviouness area (errs) 810 a volume rgdS40erdr area 540 surface area 380agWaee 1.5 depth Filter rate Time to infiltrate SAND FILTER BASIN CALCULATIONS 1'stam 3865.95 Cuft 7.087036385 tvs for the 1' event to chain though send ®0.04 gaVmhnr2 Bev through send .04ga9mirM•2 8.91E-05 m&socA 0.151526887 oMsec Send, not oudall pipe Llmlfing Factor area of am opening 0.001 sal B ®85' of 0.5In openings each .5 fast or 340 openings full flow through all openings 2.578 cis through openings hrn Bon through 6' pips (miter send) 0.467 cis through pipe DESIGN VOLUME EVENT event 1' 1 Design Parameters 47915 arpervious(eq B) 1.5 drainage area ACRES 0.092436975 %of see developed DESIGN VOLUME 0.7.1 rv-.05..009(%ImPeM0us) 3885.95 REDD voarne-m*dra tag*J12) 3993 From TR55 . cos , rhw* STAGE -STORAGE INov2 zoos �:.LScv� w0001 SEDIMENT CHAMBER VOLUME ELEV OF PROVO PROVIDED REOD PROVIDED ELEV INCREMENTAL TOTAL RODSED SEDIMENT SEDIMENT SEDIMENT STORMWATER FREEBOARD 20 DELTAAREA 1.2 0.9 LENGTH 85 83.2 WIDTH 20.3 19.1 DELTAELEV 0.4 AREA 1726 1589 VOLUME 663 VOLUME 3054 VOLUME, $10 CU FT VOLUME 01.5 DEPTH SURFACE AREA (Sq Ft) 01.5 DEPTH SURFACE AREA (Sq F0 VOLUME 663 BY-PASS F19.4� 19 V-MEAD 18.7 3 3 - 3 - 3.6 80.2 77.2 -74I2- 70.6 18.2 15.2 -12.2 8.6 0.3 0.5 0.5 0.6 1460 _7173_ 905 607 457 -_658_� 520 454 23 _ C.- 7 756 17. 1276 905 457 658 520 WEIR TOP SAND 17.7 17.1 BOTTOM 16.2 5.4 65.2 / 0.9 65 303 303 9715 17.20 1276 905 540 2298 SAND FILTER CHAMBER VOLUME ELEV OF PROVD PROVIDED REDD PROVIDED ELEV INCREMENTAL TOTAL ROD FILTER SAND FILTER SAND FILTER SAND FILTER STORMWATER FREEBOARD 20_ DELTAAREA 1.2 0.9 LENGTH 85 83.2 WIDTH 20.9 20 DELTAELEV 0.4 AREA 1776.5 16U VOLUME 688 VOLUME e3062 VOLUME, 810 CU FT VOLUME ®1.S DEPTH SURFACEAREA (Sq Ft) SURFACEAR (Sq Ft) VOLUME ear BY-PASS 1 09V7 19 V-HEAD 18.7 3 3 80.2 77.2 17 15.2 0.3 0.5 1363.4 1173.M 454 634 2 19 0 454 - WEIR 2296 VOLUME ABOVE SAND FILTER 2298 2296 STORMWATER VOLUME TO 19377 -V1 44 S4-all Vol Irl%101 jam bw 6rav747d r4 alrr0av @0,4% 00.4% 00.3% 17.1 220 0,88 17.98 0.004 73 0.292 18.272 0.003 136 0.544 18.816 97 0.388 19.204 115 0.46 19.664 0.636 7.832 arbor dl"dimsr 61ubm f6 636m G.r slope 0.003 0.003 diameter 1,250 1.250 ores 1227 1,227 perimeter 3.927 3.927 R 0.313 0.313 n 0.011 0.011 pi 3.142 3.142 v (fps) 3.403 3.403 0 fop (cfs) 4.177 4.177 0 2-yr ® 4.7 inmr (cfs) 4.360 4.360 00.3% STA 0.66 17.76 0 0.219 17.979 220 0.408 18.387 293 0.291 18.678 429 0.345 19.023 525 0.636 1.277 641 7.632 15.324 61rber73i 616c732 0.003 0.003. 1.250 1.250 1.727 1.227 1927 3.927 0.313 0.313 0.011 0.011 3.142 3,142 3,403 3.403 4.177 4.177 4.000 1.615 ALL SAINTS EPISCOPAL CHURCH SAND FILTER BASIN CALCULATIONS 9120/200 ,,rend 1425-06 0&mx r ci6,i*ff O59ye,', wa KSMJ,pllc 388 McCotter Blvd, Havelock, NC 28532 61t&W21 Ck%0-,<d i5k�-t 69R-pp 0-A(cv(zgnp.s 0.003 0.005 0.687 0.500 0.500 0.349 0.196 0.196 2.094 1.571 0.157 0.125 0.011 0.011 3.142 3.142 3,142 2.234 2.378 0.780 0.467 0.799 1.196119373 0 (de) 0pair 6'bmnd 0=A(Cv(2ghy`.5 0.005 0.005172414 slope 0.500 2.000 side 0.042 diameter 0.196 2.000 Ode 0.001 area 1.571 0.030 n 0.125 4.000 bottom width 0.011 1.500 depth 3.142 9.000 area 3.142 pi 2.378 3.329 v(fps) 0.467 29.957 oC®1.5' deom 4,380 0 2-yr 04.71rVhr(ds) 10 perimeter 0.007582657 0 full (Cs) 0.9 r 2.57610337 0 fop (ds) w * COMMUNICATDJN RESULT REPORT ( OCT.11.2006 7:51RM ) P. 1 FILE MODE 704 MEMORY TX OPTION REASON FOR ERROR E-1) HANG UP OR LINE FAIL E-3) 1,10 ANSWER ADDRESS (GROUP) 9-12524445765 TTI NCDENR WIRO PAGE --- ------------- K P. 4/4 `C'/4-e74�.' E-2) BUSY E-4) NO FACSIMILE CONNECTION State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Michael F. Easley, Governor FAX COVER SHEET William G. Ross, Jr., Secretary Date: 10/10/06 No. of Pages: 4 (Incl. Cover) To: Sue Sayger From: Paul Bartlett Company: KSMJ, pllc Water Quality Section - Stormwater FAX #: (252) 444-5765 FAX #: 910-350-2004 Phone M. 910-796-7301 DWQ Stormwater Project Number: SW8 Unassigned Project Name: All Saints Church MESSAGE: Sue, A Request for Additional Information is attached for the subject project. The original will be mailed to Rev, Miller, and a copy will be mailed to you. 14 * * * COMMUNICATION RESULT REPORT ( OCT.10.2006 5:05PM ) * * * P. 1 FILE MODE 702 MEMORY TX OPTION REASON FOR ERROR E-1) HANG UP OR LINE FAIL E-3) NO ANSWER ADDRESS (GROUP) 5-12524445765 RESULT PAGE E-3)3)3)3)3) P ✓o E-2) BUSY E-4) NO FACSIMILE CONNECTION State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Michael F. Easley, Governor Date: 10/10/06 To: Sue Sayger Company: KSMJ, pllc FAX #: (252) 444-5765 William G. Ross, Jr., Secretary FAX COVER SHEET No. of Pages: 4 (Incl. Cover) From: Paul Bartlett Water Quality Section - Stormwater FAX #: 910-350-2004 Phone #: 910-796-7301 DWQ Stormwater Project Number: SW8 Unassigned Project Name: All Saints Church MESSAGE: Sue, A Request for Additional Information is attached for the subject project. The original will be mailed to Rev. Miller, and a copy will be mailed to you. If State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Michael F. Easley, Governor Date: 10/10/06 To: Sue Sayger Company: KSMJ, pllc FAX #: (252) 444-5765 William G. Ross, Jr., Secretary FAX COVER SHEET No. of Pages: 4 (Incl. Cover) From: Paul Bartlett Water Quality Section - Stormwater FAX #: 910-350-2004 Phone #: 910-796-7301 DWQ Stormwater Project Number: SWS Unassigned Project Name: All Saints Church MESSAGE: Sue, A Request for Additional Information is attached for the subject project. The original will be mailed to Rev. Miller, and a copy will be mailed to you. ENB\ptb: S:\WQS\STORMWATER\ADDINFO\2006WIISaints.oct06 127 Cardinal Drive Extension, Wilmington, NC 28405-3845 Telephone (910) 796-7215 FAX (910) 350-2004 An Equal Opportunity Affirmative Action Employer Michael F. Fasley, Govemor William G. Ross .h., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality October 10, 2006 Reverend H.G. Miller, Rector All Saints Church AMIA, Inc. 5058 Highway 70 West, Suite E4 Morehead City, NC 28557 Subject: Request for Additional Information Stormwater Project No. SW8 Unassigned# All Saints Episcopal Church Carteret County Dear Reverend Miller: The Wilmington Regional Office received a Stormwater Management Permit Application for All Saints Episcopal Church on October 10, 2006. A preliminary review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: 1. Please clarify the longitude and latitude in Section 1.7 of the application. The site appears to be closer to 34044'32" N and—76°50'22" W. i 2. /Please provide 2 copies of Sheet #2 with a signed and dated Registered Surveyor's or PE -stamp. 3. Please clearly illustrate: (a) the limits of disturbance on Sheets #3 and #4, 1,_",_�Ircluding a symbol in the legend; and (b) the drainage areas (hand -marked Sheets 42-- #4 will suffice). 4. ease provide a copy of the soil consultants report for soil type, infiltration rate, r //and SHWT at all test locations. V�! Please clarif the basin's drainage area. The calculations list 1.1 ac and the ✓✓✓ plans lis 1��a 6. Please (provide: (a) a bypass for the basin for runoff that exceeds the 1" desipp ( � p�Wp� f sYbrth;,andb) a e�ail .f the bypass structg, including invert ele atio �C.7 1 fti t1� f l yq� Co 6 low ( 9 �. 7. Please provide a cross-section detail of the basin.` 1 recomm n that the proposed weir be removed to configure the system as an infiltration basin with a bottom elevation of 17' (approx. 29" W X 66' L) using the proposed contours and 3:1 side slopes. Storage requirements are met at approximately 18.6' (see attached calculations). C,/ Please provide PE -stamped calculations incorporating the above revisions, including a stage -storage table with surface areas and accumulated volumes. NoyhCarolina A4turaUy North Carolina Division of Water Quality 127 Cardinal Drive Fxtension Wilmington, NC 28405 Phone (910) 796-7215 Customer Service Wilmington Regional Office Intemee www.ncwatetqua] ityore I Fax (910)350-2004 1-877-623-6748 An Equal OpportunilylAtf rmative Action Employer - 50% Recycledl10% Post Consumer Paper Reverend H.G. Miller October 10, 2006 Stormwater Application No. SW8 Unassigned# Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to October 18, 2006, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you need additional time to submit the information, please mail or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter. The request must indicate the date by which you expect to submit the required information. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. Please reference the State assigned project number on all correspondence. Any original documents that need to be revised have been sent to the engineer or agent. All original documents must be returned or new originals must be provided. Copies are not acceptable. If you have any questions concerning this matter please feel free to call me at (910) 796-7301. Sinc ly, Paul T. Bartlett, P.E. Environmental Engineer ENB/ptb: S:\WQS\STORMWATER\ADDINFO\2006\AIISaints.oct06 cc: Susan H. Sayger, KSMJ, pllc Paul Bartlett TppoZone - USGS Mansfield (NC) Topo Map Page 1 of 1 w •sue` � �� CappWAt Mwsobne0. Fc'ci J �• BM `�.� f �� \n 10 e, 4p, 1 J BM ig Is i ✓� f _ T 1 „ 7 p GA P, LAND x�r x2a �-may 1 � ii / J( � •` �- r �7 jJJ ,�;•`—'�l III J f,•'�l l n� r'Y f,/;Zl 4- .4 1 !i' _�--r-•'ter.--�;;`�`�„� ''` ��i,�—rqy`+ r' a _ I� � r` � i • ii Cj rJ i r d 1 M* 0 0.3 0.6 0.9 1.2 1.5 km a 0 0.1 0.2 0.3 0.4 0.5 mi 340 44' 32"N, 760 50' 22"W (NAD83/WGS84) USGS Mansfield (NC) Quadrangle M=-9.842 Projection is UTM Zone 18 NAD83 Datum G=-:L.049 http://www.topozone.com/print.asp?lat=34.74222&Ion=-76.83949&s=48&size=m&u=6... 10/ 10/2006 TopoZone - USGS Mansfield (NC) Topo Map Page 1 of 1 (Op020nel ji �rP�_ !/�,'•d.� . fggriyA 19B370DJ M,W,raAe, ��."� : •,�� BM ` y�—, ., �i; •,� I19B III I���� •- / � i .\ � J�- �+ 23I'• {Ls ti C 0F LAN w .; AND r� - I Ys $nip �J r sv nn )k 0 0.3 0.6 0.9 1.2 1.5 km 0 0.1 0.2 0.3 0.4 0.5 mi UTM 18 331565E 3845788N (NAD27) USGS Mansfield (NC) Quadrangle M=-9.842 Projection is UTM Zone 18 NAD83 Datum G=-1.049 http://www.topozone.com/print.asp?lat=34.7421 &Ion=-76.83992&s=48&size=m&u=0&1... 10/10/2006 11 'ropoZone - Bonham Heights (subdivision), USGS Mansfield (NC) Topo Map Page I of 1 iODOZOIIe• i � �� � � i - �' i ! ess�00� .�.1� ((�� .y- d ••'•'1'. Vi. n. t_ ,p, .4.` �L-// f� fl 1 ` / 1 rr 11i � .K V' '� r -� e4 1 � • !� d r � \ l OF / i y..— �' _ p �'S+.fir•..—.N�"� _ `-� r r ,M `'� �. Tram ,. 3'at"�« � �.yx2 Park ] i C `.J �. • , 4i mil.-.� I ; 7 1.• t ~-' ' q•� - ' 0 , eta ffm ` �{ , ' y •.�+•• •�`' � •tip _..,1t , ' ' _ ✓ a. C a u of)ay6eacon'r V lN7RACOABT.4 o�Dayt1@tllAn- WA7l:R4VAY qG v ..- '� , M1 sY a •. r�si ., l S ,�. M. cC1MFIrr,,71 0.3 0.6 0.9 1.2 1.5 km 0.2 0.3 0.4 0.5 mi 340 4 ' 8" ° 46' 40"W (NAD83/WGS84) s (subdivisio SGS Mansfield (NC) Quadrangle M--9.679 Projection is UTM Zone -NAD83 Datum G--1.013 http://www. topozone.com/print. asp?lat=34.72722& Ion=-76.77778 &s=48 &size=m&u=6... 10/l 0/2006 KSMJ,PLLC 388 MCCOTTER BLVD FIAVELOCK,NC 28532 252-349-5803,252-4445765 TRANSMITTAL SHEET 'I'O: FROM: DNER, Mr. Paul Bartlett Susan Sayger,PE COMPANY: DATE: KSMJ,pllc 10/5/2006 FAX NUMBER: TOTALNO. OF PAGES INCLUDING COVER: check 111IONIL NUMBER: RE: All Saints Episcopal Church SLNDER'S REBERLNCL NUMBER: YOUR REFERENCF NUMBER: ❑ URGENT X FOR REVIEW ❑ PLEASE COMMENT ❑ PLEASE REPLY ❑ PLF.ASF. RECYCLE NOTES/COMMENTS: Paul, 1-lere is the check for the additional funds. If you need anything let me know Thanks Sue 388 McCotter Blvd Havelock, NC 28532 252-444-ksmj(5765) 0c, 1. a ZO KSMJ,PLLC 388 MCCOTTER BLVD 1IAVELOCK,NC 28532 252-349-5803.252-4445765 TRANSMITTAL SHEET TO: FROM: DNER, Mr. Paul Bartlett Susan Sayger,PE COMPANY: DATE: KSMJ,pllc 10/2/2006 FAX NUMBER: TOTAL NO. OF PAGIS INCLUDING COVER: 3 PHONE NUMBER: RL: All Saints Episcopal Church SENDER'S REFERIiNCH NUMBER: YOUR REPERLNCE NUMBER: ❑ URGEINT X FOR RFV1EW ❑ PLEASE COMMENT ❑ PLEASE REPLY ❑ PLEASE RECYCt.F. NOTES/COMMENTS: Paul, Received this after I sent out the package. Please add to the review package for All Saints. As the letter and the plan states, there are no jurisdictional wetlands within the area of development Thanks Sue 388 McCotter Blvd Havelock, NC 28532 252444-ksmj(5765) ,ECEIVED L"05ll" BY_ 5t4-6100(0 TO: DNElt r COMPANY: KSMJ,pllc FAX NUMBER: PHONE? NUMBER - RE KSM),PLLC 388 MCCOTTER BLVD HAVELOCK,NC 28532 252-349-5803,252-4445765 TRANSMITTAL SHEET ✓y�/' (/� �� ,{)/ FROM: )%I, � /— Susan All Saints Episcopal Church 3 DATE: 9/28/2006 C TOTAL NO. OF PAGES INCLUDING COVER: SENDER'S RIIFLR17NCII NUMBER: YOUR to/✓ _V/ xv9tw V ) I o ❑ URGIiNT is FOR REVIEW ❑ PI.RASI3 COMMIiN'r ❑ PI.IiASIi RIiPI.Y ❑ PLEAS NOTES/COMMENTS: A, 14 11jc /vC&-d Z� �IXi^tea/�vC c zl / ��d syo3 RAi ii! ,I OCj 0 �2pp6 It7n c� z�,I .�� /r�L r-k1 ? Fyo (6hotVl, Ywc. &e,Iaiiiai7-meialcc/'(9,onJrc//cviili /aJ / cfli''ce .�'f�ar 2i12 grrr:ne� 8d'Ih; r%lYfai!/r„r/venife �iriG: /fi Wi/miny/an, ./I'�(92,00.7 DATE: September 27, 2006 Mlofine:.9/0-45Y-000/ .yn.o:.9/0-45Y- 006'0 rrrrrr. /my rmrVr. ne/ SUBJECT: Preliminary 404 wetland evaluation of the All Saints Episcopal Church Tract (-12 acres, north portion). Tract located on the W side of McCabe Road NCSR 1147, Morehead City West area, Morehead Township, Carteret County, North Carolina. UTM 18 331565 E; 3945788 N TO: All Saints Episcopal Church Ms. Susan H. Sayger PE (agent) KSMJ, PLLC 388 McCotter Blvd. Havelock, NC 28632 (252)444-5765; 349-5803 OCI 0 5 N06 Land Management Group completed a preliminary evaluation of the Saints Episcopal Church Tract (-12 acres, Phase-1 or north portion only) to determine the upper limit of potential 404 wetland areas. This evaluation was completed through transacts within the tract, aerial photo interpretation, and/or soil/vegetative investigations. A delineation of the upper limits of potential 404 wetland areas has not been performed as this is a preliminary evaluation. The currently used U.S. Army Corps/EPA "1987 Federal Wetlands Delineation Manual" was used as guidelines to determine potential 404 Wetland areas. The enclosed map shows the general locations potential of uplands vs. potential 404 wetland areas (see map). The uplands are gently rolling broad ridges of Onslow and Lynchburg soil types (see map "yellow" areas), which are currently open fields. Potential 404 wetland areas are confined and immediately adjacent to an unnamed intermittent tributary of Hull Swamp within the extreme western portion of the tract (see map "gray" area). The proposed development will be within the eastern two-thirds of the tract according to KSMJ engineering plans of Aug-2006 (see map "red" line). Thus, 404 potential 404 wetland areas would not be impacted by the proposed development activities with standard sedimentation & erosion control measures. Any final 404 Wetlands or "Waters of the U.S." delineation will need to be reviewed and surveyed before final approval by the USACOE. This report and preliminary map should be used for general planning purposes, as specific on -site evaluations, delineations, approvals, and permits are required by respective regulatory agencies before initiating any development activities. c5 ;;;; / �i / � - ✓ / 1. /" y V r Larry F. Baldwin, CPSS/SC ARCPACS #2183; NCLSS #1040 All Saints Episcopal Church Subject: All Saints Episcopal Church From: Paul Bartlett <Paul.Bartlett@ncmail.net> Date: Tue, 03 Oct 2006 10:53:01 -0400 To: Habersaygr@aol.com CC: Cameron Weaver <Cameron.Weaver@ncmail.net> Sue, The fee is $4,000 for the application since it has a pocket of high density; only $2,000.00 was submitted. Also, for page 2 of application, Section III.6, bottom of table: please enter impervious area in square feet. FAX of changes OK. Paul FAX: 910-350-2004 1 of 1 10,13/2006 10:53 AM 14 McCabe Road Vwn of Morehead City, North Carolina Stormwater Narrative 944ad«Ciaa This stormwater narrative discusses the stormwater management design and permit application for the construction of a new, slab on -grade church facility, All Saints Episcopal Church on an 11.9-arce parcel, located in the Town of Morehead City, Carteret County. Zoned residential (church facility is a permitted use), the parcel fronts McCabe Road (south of NC Highway 70) and borders on Hull Swamp Creek which ultimately drains into the White Oak River. Hull Swamp Creek is classified as a C class water. There are no applicable AECs associated with the parcel. No disturbance, grading or construction will take place within 300 feet of the creek. We see no applicable CAMA issues. There are no CAMA jurisdictional wetlands within the scope of this project, per discussions with and following letter from Land Management Group. &� &daya" Currently, the existing topography of the entire parcel is flat, with majority of the parcel draining across a minimum grade (less than one percent) draining towards the creek. For over 90% of the site, these existing drainage divides are honored, including the two existing ditch lines. These ditch lines will continue to act as vegetative filters for the parcel, including the 0.3 Acres of existing impervious surfaces which will. remain. As seen in the attached calculations, the pre-existing run-off from the site for the 2-year and 10- year event are 12.8 and 34.1 cfs, respectively. Jton" �+a-Ag" Although the project meets the requirements for low density of less than 30%, with only 1.1 Acres of impervious surface out of the total 11.9 Acres or 0.92%, we respectfully submitted this as a low density design, providing for a pocket of high density. The percentage of proposed imperviousness, includes building area (10,908 sq fl) and paved and sidewalk area (36,155 sq ft). All impervious surfaces will drain through roof drains and catch basins into culverts into a two -chamber sand infiltration basin. The 1-inch storm is completely contained, with one -foot of freeboard. Run-off will first settle through the pre-treatment, sedimentation chamber. The design meets or exceeds all DNER size and depth requirements. The entire 1-inch storm will filter through 18 inches of sand, through a filter fabric wrapped perforated 6" pvc in 7.3 hours. The 2-inch storm will drain in 24 hours. Without the basin is, as seen in the attached calculations, the post -condition run-off from the site for the 2-year and 10- year event are 16.5 and 40.8 cfs, respectively. With the basin, the post -condition run-off from the site for the 2-year and 10- year event are 14.1 and 37.5 cfs, respectively. The velocity for the 2-year event is not at an erosive levels, however, the rip -rap from the check dam will be left in place to minimize the potential for erosion in the existing channel. &dam The proposed design includes only 1.1 Acres of impervious surface out of the total 11.9 Acres or 0.92%. In addition to the existing vegetative swales that will provide filtering, we have provided stormwater management to mitigate the additional imperviousness through a two -chamber sand infiltration basin, containing the required J evenefreeboard, meeting or exceeding all DNER size and depth requirements. (Q3u -ea Susan H. Sayger,PE KSMJ,pllc 388 McCotter Blvd Havelock, NC 28532 252-349-5803 252-444-5765 s r-` Page 1 of 1 Date: 9/20/2006 Click here to: View Document Filings Corporation Names Name Name Type NC All Saints Church AMIA, Inc. Legal Non -Profit Corporation Information SOSID: 0680366L Status: Cun•ent-Active 2 2p06 Date Formed: 6/24/2003 Citizenship: Domestic �Vo State of Inc.: NC $`Z Duration: Perpetual Registered Agent Agent Name: Grayson, John H. Registered Office Address: 2012 Evans Street Morehead City NC 28557 Registered Mailing Address: Principal Office Address: 2012 Evans Street Morehead City NC 28557 Principal Mailing Address: No Address http://www.secretary.state.nc.us/CorporationsICorp.aspx?Pitemld=5657825&Printer—True 9/20/2006 Y . t 6F �:,.. ��.�ii, r:L - ., �- � .! ` /; Page 1 of 1 Detailed view for record 1 View in new window I Print Field Value AREA 456688.39186 PERIMETER 3931.21923 PARCEL83_ 18943 PARGEL83_I 18945 WHAT 0 PIN MAPNUM 6346 BLOCK 87 PDOT 8740 CONDO_ MOTHER 0 MAPNAM 634608 PRID PIN15 OWNER 634608878740000 ALL SAINTS CHURCH AMIA INC DBOOK 1069 DPAGE 192 DDATE 0 SALE_PRICE 0 TAX_VALUE LAND_VALUE 941 00 94160 STRUC VAL 0 OTHER_VAL 0 BLT_CONDO 0 HOUSE_NUM 0000000 DIRECTION Field Value ST_NAME ST_TYPE CITY NEWPORT ZIP 28570 MAIL_HOUSE MAIL_DIR MAIL_ST MAIL_STTYP MOREHEAD CITY MAIL_CITY MAIL_STATE NC MAIL_ZIP 28557 MAIL_POBOX PO BOX 309 TOWNSHIP MOREHEAD CITY_LIMIT NBHD FIRE_DIST 0 WILDWOOD FIRE RESCUE_DST PART TR1 MCELMON PROPERTY LEGAL_DSC TOTAL_ACR 10.77 Y_BLT HOUS 0 TOT_SO_FT BATHROOMS 0 0 BEDROOMS 0 NOISE_LVL RISK_LEVEL Click -Here -for Disclaimer LACUIZ http://maps.co.carteret.nc.us//details.htm 9/26/2006 S r �3 r . r r r Ir ` f- 1 1 j" Ili. all saints 2006-004 GCZ G Z ZGG6 Proposed Conditions for volume req �.. Name of printed page file: TR20.out (continued) STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area ID or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) 21.990 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.034 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.079 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.123 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.167 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.211 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.255 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.300 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.344 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.388 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.432 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.477 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.521 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.565 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.609 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.653 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.698 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.742 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.786 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.830 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.074 0.06 0.06 0.06 0.06 0.06 0.06 0.06 WinTR-20 Version 1.0 Page 5 09/1B/2006 15:34 all saints 2006-004 Proposed Conditions for volume req Line Start Time ------------ Flow Values @ time increment of 0.006 hr------------ (hr) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 22.919 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.963 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.007 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.051 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.095 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.140 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.184 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.228 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.272 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.317 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.361 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.405 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.449 0.06 0.06 0.06 0.05 0.05 0.05 0.05 23.493 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.538 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.582 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.626 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.670 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.714 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.759 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.803 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.847 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.891 0.05 0.05 0.05 0.05 0.05 0.05 0.05 WinTR-55, Version 1.00.08 Page 6 9/18/2006 3:36:45 PM all saints 2006-004 Proposed Conditions for volume req Name of printed page file: TR20.out (continued) STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area ID or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) 13.502 0.21 0.21 0.21 0.21 0.21 0.21 0.21 13.546 0.21 0.21 0.21 0.21 0.21 0.21 0.20 13.590 0.20 0.20 0.20 0.20 0.20 0.20 0.20 13.634 0.20 0.20 0.20 0.20 0.20 0.20 0.20 13.679 0.20 0.20 0.20 0.20 0.20 0.20 0.20 13.723 0.20 0.20 0.20 0.20 0.20 0.20 0.20 13.767 0.20 0.20 0.20 0.20 0.20 0.20 0.20 13.811 0.20 0.20 0.20 0.20 0.20 0.20 0.20 13.855 0.19 0.19 0.19 0.19 0.19 0.19 0.19 13.900 0.19 0.19 0.19 0.19 0.19 0.19 0.19 13.944 0.19 0.19 0.19 0.19 0.19 0.19 0.19 13.988 0.19 0.19 0.19 0.19 0.19 0.19 0.19 14.032 0.19 0.19 0.19 0.19 0.19 0.18 0.18 14.077 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.121 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.165 0.18 0.18 0.18 0.18 0.1B 0.18 0.18 14.209 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.253 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.298 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.342 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.386 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.430 0.18 0.18 0.18 0.18 0.1B 0.18 0.18 14.474 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.519 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.563 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.607 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.651 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.695 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.740 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.784 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.828 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.872 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.917 0.17 0.17 0.17 0.17 0.17 0.17 0.16 14.961 0.16 0.16 0.16 0.16 0.16 0.16 0.16 15.005 0.16 0.16 0.16 0.16 0.16 0.16 0.16 WinTR-20 Version 1.0 Page 7 09/1B/2006 15:34 all saints 2006-004 Proposed Conditions for volume req Line Start Time ------------ Flow Values @ time increment of 0.006 hr------------ (hr) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 15.049 0.16 0.16 0.16 0.16 0.16 0.16 0.16 15.093 0.16 0.16 0.16 0.16 0.16 0.16 0.16 15.138 0.16 0.16 0.16 0.16 0.16 0.16 0.16 15.182 0.16 0.16 0.16 0.16 0.16 0.16 0.16 15.226 0.16 0.16 0.16 0.16 0.16 0.16 0.15 15.270 0.15 0.15 0.15 0.15 0.15 0.15 0.15 15.314 0.15 0.15 0.15 0.15 0.15 0.15 0.15 15.359 0.15 0.15 0.15 0.15 0.15 0.15 0.15 15.403 0.15 0.15 0.15 0.15 0.15 0.15 0.15 WinTR-55, Version 1.00.08 Page 8 9/18/2006 3:36:45 PM all saints 2006-004 Proposed Conditions for volume req Name of printed page file: TR20.out (continued) STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area ID or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) 17.392 0.10 0.10 0.10 0.10 0.10 0.10 0.10 17.437 0.10 0.10 0.10 0.10 0.10 0.10 0.10 17.481 0.10 0.10 0.10 0.10 0.10 0.10 0.10 17.525 0.10 0.10 0.10 0.10 0.10 0.09 0.09 17.569 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.613 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.658 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.702 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.746 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.790 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.834 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.879 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.923 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.967 0.09 0.09 0.09 0.09 0.08 0.08 0.08 18.011 0.08 0.08 0.08 0.08 0.08 O.OB 0.08 1B.055 0.08 0.08 0.06 0.08 0.08 0.08 0.08 18.100 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.144 0.08 0.08 0.08 0.08 0.08 0.08 0.08 10.188 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.232 0.08 0.08 0.08 0.08 O.OB 0.08 0.08 18.277 0.08 0.08 0.08 0.08 0.06 0.08 0.08 18.321 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.365 0.06 0.08 0.08 0.08 0.08 0.08 0.08 18.409 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.453 0.08 0.08 0.08 0.08 0.00 0.08 0.08 18.498 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.542 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.586 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.630 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.674 0.08 O.OB 0.08 0.08 0.08 0.08 0.08 18.719 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.763 0.08 0.06 0.08 0.08 0.08 0.08 0.08 L8.807 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.851 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.895 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.940 0.08 0.OB 0.08 0.08 0.08 0.08 0.08 18.984 0.09 0.OB 0.08 0.08 0.08 0.08 0.06 19.028 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.072 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.117 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.161 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.205 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.249 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.293 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.338 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.382 0.08 O.OB 0.08 0.08 0.08 0.08 0.08 19.426 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.470 0.08 0.08 0.08 0.08 0.08 0.06 0.08 19.514 0.08 0.08 0.08 0.08 0.08 0.08 0.08 WinTR-20 Version 1.0 Page 9 09/18/2006 15:34 all saints 2006-004 Proposed Conditions for volume req WinTR-55, Version 1.00.08 Page 10 9/18/2006 3:36:45 PM all saints 2006-004 Proposed Conditions for volume req Name of printed page file: TR20.out (continued) STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area ID or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) Line Start Time ------------ Flow Values @ time increment of 0.006 hr------------ (hr) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 19.559 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.603 0.08 0.08 0.08 0.07 0.07 0.07 0.07 19.647 0.07 0.07 0.07 0.07 0.07 0.07 0.07 19.691 0.07 0.07 0.07 0.07 0.07 0.07 0.07 19.735 0.07 0.07 0.07 0.07 0.07 0.07 0.07 19.780 0.07 0.07 0.07 0.07 0.07 0.07 0.07 19.824 0.07 0.07 0.07 0.07 0.07 0.07 0.07 19.868 0.07 0.07 0.07 0.07 0.07 0.07 0.07 19.912 0.07 0.07 0.07 0.07 0.07 0.07 0.07 19.957 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.001 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.045 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.089 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.133 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.178 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.222 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.266 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.310 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.354 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.399 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.443 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.487 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.531 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.575 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.620 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.664 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.708 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.752 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.797 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.841 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.885 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.929 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.973 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.018 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.062 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.106 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.150 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.194 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.239 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.283 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.327 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.371 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.415 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.460 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.504 0.07 0.07 0.07 0.07 0.07 0.07 0.06 21.548 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.592 0.06 0.07 0.07 0.07 0.06 0.06 0.06 21.637 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.681 0.06 0.06 0.06 0.06 0.06 0.06 0.06 WinTR-55, Version 1.00.08 Page 11 9/18/2006 3:36:45 PM all saints 2006-004 Proposed Conditions for volume req Name of printed page file: TR20.out (continued) STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow Reach Area ID or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) 21.725 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.769 0.06 0.06 0.06 0.06 0.06 0.06 0.06 WinTR-20 Version 1.0 Page 10 09/18/2006 15:34 all saints 2006-004 Proposed Conditions for volume req Line Start Time ------------ Flow Values @ time increment of 0.006 hr------------ (hr) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 21.813 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.85E 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.902 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.946 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.990 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.034 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.079 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.123 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.167 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.211 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.255 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.300 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.344 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.388 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.432 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.477 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.521 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.565 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.609 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.653 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.698 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.742 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.786 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.830 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.874 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.919 0.06 0.06 0.06 0.06 0.06 0.06 0.06 22.963 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.007 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.051 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.095 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.140 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.184 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.22E 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.272 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.317 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.361 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.405 0.06 0.06 0.06 0.06 0.06 0.06 0.06 23.449 0.06 0.06 0.06 0.05 0.05 0.05 0.05 23.493 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.538 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.582 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.626 0.05 0.05 0.05 0.05 0.05 0.05 0.05 WinTR-55, Version 1.00.08 Page 12 9/18/2006 3:36:45 PM all saints 2006-004 Proposed Conditions for volume req Name of printed page file: TR20.out (continued) STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area IO or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) 23.670 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.714 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.759 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.803 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.847 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.891 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.935 0.05 0.05 0.05 0.05 0.05 0.05 0.05 23.980 0.05 0.05 0.05 0.05 0.05 0.05 0.05 WinTR-20 Version 1.0 Page 11 09/18/2006 15:34 all saints 2006-004 Proposed Conditions for volume req Area or Drainage ----------- Peak Flow by Storm ----------- Reach Area Alternate 1-Yr Identifier (sq mi) (cfs) (cfs) (cfs) (cfs) (cfs) Tract 1 0.02 0.5 OUTLET 0.02 0.5 WinTR-55, Version 1.00.08 Page 13 9/18/2006 3:36:45 PM all saints 2006-004 Proposed Conditions for volume req Name of printed page file: TR20.out STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow --- Reach Area ID or Amount Elevation Time Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) WinTR-20 Version 1.0 Page 12 (continued) Rate (csm) 09/18/2006 15:34 WinTR-55, Version 1.00.08 Page 14 9/19/2006 3:36:45 PM habersaygr all saints 20 -004 Proposed Conditions r volume req t orth Carolina Rydrograph Peak/Peak Time Table Sub -Area Peak Flow and Peak Time (hr) by Rainfall Return Period or Reach 2-Yr 10-Yr 25-Yr 50-Yr 100-Yr 1-Yr Identifier (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (hr) (hr) (hr) (hr) (hr) (hr) ---------------------------------------------------------------------- SUBAREAS Tract 1 16.54 40.77 49.55 60.56 71.81 0.45 12.12 12.12 12.11 12.11 12.11 12.35 REACHES OUTLET 16.54 40.77 49.55 60.56 71.81 0.45 OCj 0 2 2006 WinTR-55, Version 1.00.08 Page 1 9/28/2006 2:18:07 PM WinTR-55 Current Data Description --- Identification Data --- User: habersaygr Date: 9/18/2006 Project: all saints 2006-004 Units: English SubTitle: Proposed Conditions for volume req Areal Units: Acres State: North Carolina County: Carteret Filename: C:\mclure 2006-0004\calculations\proposed-rqd volumeAll Saints.w55 --- Sub -Area Data --- Name Description Reach Arealac) RCN Tc ------------------------------------------------------------------------------ Tract 1 entiretractsnewimpervs Outlet 11.9 64 0.1 Total area: 11.90 (ac) --- Storm Data -- Rainfall Depth by Rainfall Return Period 2-Yr 5-Yr 10-Yr 25-Yr 50-Yr 100-Yr 1-Yr (in) (in) (in) (in) (in) --------- (in) (in) ------7--------- 4. ----------- — 6.27.4 - 83 - 9 ----------- 1052.0 Storm Data Source: User -provided custom storm data Rainfall Distribution Type: Type III Dimensionless Unit Hydrograph: <standard> WinTR-55, Version 1.00.08 Page 1 9/18/2006 3:37:01 PM habersaygr all saints 2006-004 Proposed Conditions for volume req Carteret County, North Carolina Watershed Peak Table Sub -Area Peak Flow by Rainfall Return Period or Reach 1-Yr Identifier (cfs) ------------------------------------------------------- SUBAREAS Tract 1 0.45 REACHES OUTLET 0.45 WinTR-55, Version 1.00.08 Page 1 9/18/2006 3:37:01 PM habersaygr all saints 2006-004 Proposed Conditions for volume req Carteret County, North Carolina Sub -Area Time of Concentration Details Sub -Area Flow Mannings's End Wetted Travel Identifier/ Length Slope n Area Perimeter Velocity Time -------------------------------------------------------------------------------- (ft) (ft/ft) (sq ft) (ft) (ft/sec) (hr) Tract 1 SHALLOW 50 0.0080 4.7 0.010 CHANNEL 641 0.0030 0.013 1.30 3.50 3.237 0.055 Time of Concentration 0.1 WinTR-55, Version 1.00.08 Page 1 9/18/2006 3:37:01 PM habersaygr all saints 2006-004 Proposed Conditions for volume req Carteret County, North Carolina Sub -Area Land Use and Curve Number Details Sub -Area Hydrologic Sub -Area Curve Identifier Land Use Soil Area Number ----------------------- __------------------------------------- Group (ac) Tract 1 Open space; grass cover > 75% (good) B 10.8 61 Paved parking lots, roofs, driveways B 1.1 98 Total Area / Weighted Curve Number 11.9 64 WinTR-55, Version 1.00.08 Page 1 9/18/2006 3:37:01 PM habersaygr all saints 2006-004 Proposed Conditions for volume req Carteret County, North Carolina Sub -Area Summary Table Sub -Area Drainage Time of Curve Receiving Identifier Area Concentration Number Reach (ac) (hr) -------------------------------------------------------- Tract 1 1.1.90 0.100 64 Outlet Total Area: 11.90 (ac) Sub -Area Description ------------------------ entiretract&newimpervs WinTR-55, Version 1.00.08 Page 1 9/18/2006 3:37:01 PM habersaygr all saints 2006-004 Proposed Conditions for volume req Carteret County, North Carolina Storm Data Rainfall Depth by Rainfall Return Period 2-Yr 5-Yr 10-Yr 25-Yr 50-Yr 100-Yr 1-Yr (in) (in) (in) (in) (in) (in) (in) ----------------------------------------------------------------------------- 4.7 6.2 7.4 8.3 9.4 10.5 2.0 Storm Data Source: User -provided custom storm data Rainfall Distribution Type: Type III Dimensionless Unit Hydrograph: <standard> WinTR-55, Version 1.00.08 Page 1 9/18/2006 3:37:01 PM habersaygr all saints 2006-004 Proposed Conditions for volume req Carteret County, North Carolina Hydrograph Peak/Peak Time Table Sub -Area Peak Flow and Peak Time (hr) by Rainfall Return Period or Reach 1-Yr Identifier (cfs) (hr) ------------------------------------------------------------------------ SUBAREAS Tract 1 0.45 12.35 REACHES OUTLET 0.45 WinTR-55, Version 1.00.08 Page 1 9/18/2006 3:37:01 PM all saints 2006-004 Proposed Conditions for volume req Name of printed page file: TR20.out STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area IO or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) Tract 1 0.019 0.118 12.35 0.45 24.35 Line Start Time ------------ Flow Values @ time increment of 0.006 hr------------ (hr) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 12.131 0.05 0.07 0.08 0.10 0.11 0.13 0.15 12.175 0.16 0.18 0.20 0.21 0.23 0.25 0.27 12.220 0.28 0.30 0.31 0.32 0.33 0.34 0.35 12.264 0.36 0.37 0.38 0.39 0.40 0.40 0.41 12.308 0.42 0.43 0.44 0.44 0.45 0.45 0.45 12.352 0.45 0.45 0.45 0.45 0.45 0.45 0.45 12.397 0.45 0.45 0.45 0.45 0.45 0.45 0.45 12.441 0.44 0.43 0.42 0.41 0.41 0.40 0.39 12.485 0.38 0.37 0.37 0.37 0.36 0.36 0.36 12.529 0.35 0.35 0.34 0.33 0.33 0.32 0.31 12.573 0.30 0.30 0.29 0.29 0.28 0.28 0.28 12.618 0.28 0.28 0.27 0.27 0.27 0.27 0.27 12.662 0.27 0.26 0.26 0.26 0.26 0.26 0.26 12.706 0.26 0.26 0.26 0.26 0.26 0.26 0.26 12.750 0.26 0.26 0.26 0.25 0.25 0.25 0.25 12.794 0.25 0.25 0.25 0.25 0.25 0.25 0.25 12.839 0.25 0.25 0.25 0.25 0.25 0.24 0.24 12.883 0.24 0.24 0.24 0.24 0.24 0.24 0.24 12.927 0.24 0.24 0.24 0.24 0.23 0.23 0.23 12.971 0.23 0.23 0.23 0.23 0.23 0.22 0.22 13.015 0.22 0.22 0.22 0.22 0.22 0.22 0.22 13.060 0.22 0.22 0.22 0.22 0.22 0.21 0.21 13.104 0.21 0.21 0.21 0.21 0.21 0.21 0.21 13.148 0.21 0.21 0.21 0.21 0.21 0.21 0.21 13.192 0.21 0.21 0.21 0.21 0.21 0.21 0.21 13.237 0.21 0.21 0.21 0.21 0.21 0.21 0.21 13.2B1 0.21 0.21 0.21 0.21 0.21 0.21 0.21 13.325 0.21 0.21 0.21 0.21 0.21 0.21 0.21 13.369 0.21 0.21 0.21 0.21 0.21 0.21 0.21 13.413 0.21 0.21 0.21 0.21 0.21 0.21 0.21 13.458 0.21 0.21 0.21 0.21 0.21 0.21 0.21 13.502 0.21 0.21 0.21 0.21 0.21 0.21 0.21 13.546 0.21 0.21 0.21 0.21 0.21 0.21 0.20 13.590 0.20 0.20 0.20 0.20 0.20 0.20 0.20 13.634 0.20 0.20 0.20 0.20 0.20 0.20 0.20 13.679 0.20 0.20 0.20 0.20 0.20 0.20 0.20 13.723 0.20 0.20 0.20 0.20 0.20 0.20 0.20 13.767 0.20 0.20 0.20 0.20 0.20 0.20 0.20 13.811 0.20 0.20 0.20 0.20 0.20 0.20 0.20 13.855 0.19 0.19 0.19 0.19 0.19 0.19 0.19 WinTR-20 Version 1.0 Page 1 09/18/2006 15:34 all saints 2006-004 Proposed Conditions for volume req Line WinTR-55, Version 1.00.08 Page 1 9/18/2006 3:36:45 PM all saints 2006-004 Proposed Conditions for volume req Name of printed page file: TR20.out (continued) STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area ID or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) Start Time ------------ Flow Values @ time increment of 0.006 hr------------ (hr) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 13.900 0.19 0.19 0.19 0.19 0.19 0.19 0.19 13.944 0.19 0.19 0.19 0.19 0.19 0.19 0.19 13.988 0.19 0.19 0.19 0.19 0.19 0.19 0.19 14.032 0.19 0.19 0.19 0.19 0.19 0.18 0.18 14.077 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.121 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.165 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.209 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.253 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.298 0.18 0.18 0.10 0.18 0.18 0.18 0.18 14.342 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.386 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.430 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.474 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.519 0.18 0.18 0.18 0.18 0.18 0.18 0.18 14.563 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.607 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.651 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.695 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.740 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.784 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.628 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.872 0.17 0.17 0.17 0.17 0.17 0.17 0.17 14.917 0.17 0.17 0.17 0.17 0.17 0.17 0.16 14.961 0.16 0.16 0.16 0.16 0.16 0.16 0.16 15.005 0.16 0.16 0.16 0.16 0.16 0.16 0.16 15.049 0.16 0.16 0.16 0.16 0.16 0.16 0.16 15.093 0.16 0.16 0.16 0.16 0.16 0.16 0.16 15.138 0.16 0.16 0.16 0.16 0.16 0.16 0.16 15.182 0.16 0.16 0.16 0.16 0.16 0.16 0.16 15.226 0.16 0.16 0.16 0.16 0.16 0.16 0.15 15.270 0.15 0.15 0.15 0.15 0.15 0.15 0.15 15.314 0.15 0.15 0.15 0.15 0.15 0.15 0.15 15.359 0.15 0.15 0.15 0.15 0.15 0.15 0.15 15.403 0.15 0.15 0.15 0.15 0.15 0.15 0.15 15.447 0.15 0.15 0.15 0.15 0.15 0.15 0.15 15.491 0.15 0.15 0.15 0.15 0.15 0.15 0.15 15.535 0.15 0.14 0.14 0.14 0.14 0.14 0.14 15.580 0.14 0.14 0.14 0.14 0.14 0.14 0.14 15.624 0.14 0.14 0.14 0.14 0.14 0.14 0.14 15.668 0.14 0.14 0.14 0.14 0.14 0.14 0.14 15.712 0.14 0.14 0.14 0.14 0.14 0.14 0.14 15.757 0.14 0.14 0.14 0.14 0.13 0.13 0.13 15.801 0.13 0.13 0.13 0.13 0.13 0.13 0.13 15.845 0.13 0.13 0.13 0.13 0.13 0.13 0.13 15.889 0.13 0.13 0.13 0.13 0.13 0.13 0.13 15.933 0.13 0.13 0.13 0.13 0.13 0.13 0.13 15.978 0.13 0.13 0.13 0.13 0.13 0.13 0.13 16.022 0.12 0.12 0.12 0.12 0.12 0.12 0.12 16.O66 0.12 0.12 0.12 0.12 0.12 0.12 0.12 16.11.0 0.12 0.12 0.12 0.12 0.12 0.12 0.12 WinTR-55, Version 1.00.08 Page 2 9/18/2006 3:36:45 PM all saints 2006-004 Proposed Conditions for volume req Name of printed page file: TR20.out (continued) STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area ID or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) WinTR-20 Version 1.0 Page 2 09/18/2006 15:34 all saints 2006-004 Proposed Conditions for volume req Line Start Time ------------ Flow Values @ time increment of 0.006 hr------------ (hr) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 16.154 0.12 0.12 0.12 0.12 0.12 0.12 0.12 16.199 0.12 0.12 0.12 0.12 0.12 0.12 0.12 16.243 0.12 0.12 0.12 0.12 0.12 0.12 0.12 16.287 0.12 0.12 0.12 0.12 0.12 0.12 0.12 1.6.331 0.12 0.12 0.12 0.12 0.12 0.12 0.12 16.375 0.12 0.12 0.12 0.12 0.12 0.12 0.12 1.6.420 0.12 0.12 0.12 0.12 0.12 0.12 0.12 1.6.464 0.12 0.12 0.12 0.12 0.12 0.12 0.12 16.508 0.12 0.12 0.12 0.12 0.11 0.11 0.11 16.552 0.11 0.11 0.11 0.11 0.11 0.11 0.11 16.597 0.11 0.11 0.11 0.11 0.11 0.11 0.11 1.6.641 0.11 0.11 0.11 0.11 0.11 0.11 0.11 16.685 0.11 0.11 0.11 0.11 0.11 0.11 0.11 16.729 0.11 0.11 0.11 0.11 0.11 0.11 0.11 16.773 0.11 0.11 0.11 0.11 0.11 0.11 0.11 16.818 0.11 0.11 0.11 0.11 0.11 0.11 0.11 16.862 0.11 0.11 0.11 0.11 0.11 0.11 0.11 16.906 0.11 0.11 0.11 0.11 0.11 0.11 0.11 16.950 0.11 0.11 0.11 0.11 0.11 0.11 0.11 16.994 0.11 0.11 0.11 0.11 0.11 0.11 0.11 17.039 0.11 0.11 0.11 0.10 0.10 0.10 0.10 17.083 0.10 0.10 0.10 0.10 0.10 0.10 0.10 17.127 0.10 0.10 0.10 0.10 0.10 0.10 0.10 17.171 0.10 0.10 0.10 0.10 0.10 0.10 0.10 17.215 0.10 0.10 0.10 0.10 0.10 0.10 0.10 17.260 0.10 0.10 0.10 0.10 0.10 0.10 0.10 17.304 0.10 0.10 0.10 0.10 0.10 0.10 0.10 17.348 0.10 0.10 0.10 0.10 0.10 0.10 0.10 17.392 0.10 0.10 0.10 0.10 0.10 0.10 0.10 17.437 0.10 0.10 0.10 0.10 0.10 0.10 0.10 17.481 0.10 0.10 0.10 0.10 0.10 0.10 0.10 17.525 0.10 0.10 0.10 0.10 0.10 0.09 0.09 17.569 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.613 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.658 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.702 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.746 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.790 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.834 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.879 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.923 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.967 0.09 0.09 0.09 0.09 0.08 0.08 0.08 18.011 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.055 0.08 0.08 0.08 0.08 0.08 0.08 0.08 WinTR-55, Version 1.00.08 Page 3 9/18/2006 3:36:45 PM all saints 2006-004 Proposed Conditions for volume req Name of printed page file: TR20.out (continued.) STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area ID or Amount Elevation Time Rate Rate Identifier (so mi) Location (in) (ft) (hr) (cfs) (csm) 18.100 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.144 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.188 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.232 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.277 0.08 0.08 0.08 0.08 0.08 0.08 0.08 1.8.321 0.08 0.08 0.08 0.08 0.08 0.08 0.08 1B.365 0.08 0.08 0.08 0.08 0.08 0.08 0.08 WinTR-20 Version 1.0 Page 3 09/18/2006 15:34 all saints 2006-004 Proposed Conditions for volume req Line Start Time ------------ Flow Values @ time increment of 0.006 hr------------ (hr) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 18.409 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.453 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.498 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.542 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.586 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.630 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.674 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.719 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.763 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.807 0.08 0.08 0.08 0.08 0.06 0.08 0.08 18.851 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.895 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.940 0.08 0.08 0.08 0.08 0.08 0.08 0.08 18.984 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.028 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.072 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.117 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.161 0.OB 0.08 0.08 0.08 0.08 0.08 0.08 19.205 0.08 0.08 0.08 O.OB 0.08 0.08 O.OB 19.249 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.293 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.338 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.382 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.426 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.470 0.08 0.08 0.08 0.08 O.OB 0.08 0.08 19.514 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.559 0.08 0.08 0.08 0.08 0.08 0.08 0.08 19.603 0.08 0.09 0.08 0.07 0.07 0.07 0.07 19.647 0.07 0.07 0.07 0.07 0.07 0.07 0.07 19.691 0.07 0.07 0.07 0.07 0.07 0.07 0.07 19.735 0.07 0.07 0.07 0.07 0.07 0.07 0.07 19.780 0.07 0.07 0.07 0.07 0.07 0.07 0.07 19.824 0.07 0.07 0.07 0.07 0.07 0.07 0.07 19.868 0.07 0.07 0.07 0.07 0.07 0.07 0.07 19.912 0.07 0.07 0.07 0.07 0.07 0.07 0.07 19.957 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.001 0.07 0.07 0.07 0.07 0.07 0.07 0.07 WinTR-55, Version 1.00.08 Page 4 9/1B/2006 3:36:45 PM all saints 2006-004 Proposed Conditions for volume req Name of printed page file: TR20.out (continued) STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area ID or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) 20.045 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.089 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.133 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.178 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.222 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.266 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.310 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.354 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.399 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.443 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.487 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.531 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.575 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.620 0.07 0.07 0.07 0.07 0.07 0.07 0.07 WinTR-20 Version 1.0 Page 4 09/18/2006 15:34 all saints 2006-004 Proposed Conditions for volume req Line Start Time ------------ Flow Values @ time increment of 0.006 hr------------ (hr) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 20.664 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.708 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.752 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.797 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.841 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.885 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.929 0.07 0.07 0.07 0.07 0.07 0.07 0.07 20.973 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.018 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.062 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.106 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.150 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.194 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.239 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.283 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.327 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.371 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.415 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.460 0.07 0.07 0.07 0.07 0.07 0.07 0.07 21.504 0.07 0.07 0.07 0.07 0.07 0.07 0.06 21.548 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.592 0.06 0.07 0.07 0.07 0.06 0.06 0.06 21.637 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.681 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.725 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.769 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.813 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.858 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.902 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.946 0.06 0.06 0.06 0.06 0.06 0.06 0.06 WinTR-55, Version 1.00.08 Page 5 9/18/2006 3:36:45 PM habersaygr all saints 2006-00 Existing Conditions Ca Nos,' Carol' a Sub -Area Time of Concentration Details Sub -Area Flow Mannings's Identifier/ Length Slope n (ft) (ft/ft) ----------------------------------------- Tract 1 SHEET 25 0.0080 0.060 SHALLOW 825 0.0080 4.7 End Wetted Travel Area Perimeter Velocity Time (sq ft) (ft) (ft/sec) (hr) ------------------------------------- 0.031 0.159 Time of Concentration .19 4 ��_ ' - J oCT U `L ZOU6 WinTR-55, Version 1.00.08 Page 1 9/14/2006 3:01:01 P14 habersaygr all saints 2006-004 Existing Conditions Carteret County, North Carolina Sub -Area Land Use and Curve Number Details Sub -Area Hydrologic Sub -Area Identifier Land Use Soil Area Group (ac) ------------------------------------------------------------------------- Tract 1 Open space; grass cover > 75% (good) B 11.6 Paved parking lots, roofs, driveways B .3 Total Area / Weighted Curve Number 11.9 Curve Number 61 98 62 WinTR-55, Version 1.00.08 Page 1 9/14/2006 3:01:01 PM habersaygr all saints 2006-004 Existing Conditions Carteret County, North Carolina Sub -Area Summary Table Sub -Area Drainage Time of Curve Receiving Sub -Area Identifier Area Concentration Number Reach Description (ac) (hr) -------------------------------------------------------------------------------- Tract 1 11.90 0.190 62 Outlet Existing Land Use Total Area: 11.90 (ac) WinTR-55, Version 1.00.08 Page 1 9/14/2006 3:01:01 PM habersaygr all saints 2006-004 Existing Conditions Carteret County, North Carolina Storm Data Rainfall Depth by Rainfall Return Period 2-Yr 5-Yr 10-Yr 25-Yr 50-Yr 100-Yr 1-Yr (in) (in) (in) (in) (in) (in) (in) ------------------------------------------------------------------------------ 4.7 6.2 7.4 8.3 9.4 10.5 2.0 Storm Data Source: User -provided custom storm data Rainfall Distribution Type: Type III Dimensionless Unit Hydrograph: <standard> WinTR-55, Version 1.00.08 Page 1 9/14/2006 3:01:01 PM habersaygr all saints 2006-004 Existing Conditions Carteret County, North Carolina Watershed Peak Table Sub -Area Peak Flow by Rainfall Return Period or Reach 2-Yr 10-Yr 100-Yr 1-Yr Identifier ---------------------------------------------------------------------------------- (cfs) (cfs) (cfs) (cfs) SUBAREAS Tract 1 12.84 34.12 62.11 0.20 REACHES OUTLET 12.84 34.12 62.11 0.20 WinTR-55, Version 1.00.08 Page 1 9/14/2006 3:01:01 PM habersaygr all saints 2006-004 Existing Conditions Carteret County, North Carolina Hydrograph Peak/Peak Time Table Sub -Area Peak Flow and Peak Time (hr) by Rainfall Return Period or Reach 2-Yr 10-Yr 100-Yr 1-Yr Identifier (cfs) (cfs) (cfs) (cfs) (hr) (hr) (hr) (hr) ---------------------------------------------------------------------- SUBAREAS Tract 1 12.84 34.12 62.11 0.20 12.17 12.16 12.15 12.52 REACHES OUTLET 12.89 34.12 62.11 0.20 WinTR-55, Version 1.00.08 Page 1 9/14/2006 3:01:01 PM: WinTR-55 Current Data Description --- Identification Data --- User: habersaygr Date: 9/14/2006 Project: all saints 2006-004 Units: English SubTitle: Existing Conditions Areal Units: Acres State: North Carolina County: Carteret Filename: C:\mclure 2006-0004\calculations\preexistingAll Saints.w55 --- Sub -Area Data --- Name ------------------------------------------------------------------------------ Description Reach Area(ac) RCN Tc Tract 1 Existing Land Use Outlet 11.9 62 .19 Total area: 11.90 (ac) --- Storm Data -- Rainfall Depth by Rainfall Return Period 2-Yr 5-Yr 10-Yr 25-Yr 50-Yr 100-Yr 1-Yr (in) (in) (in) (in) (in) (in) (in) -------------------------------------------------------------------------------- 4.7 6.2 7.4 8.3 9.4 10.5 2.0 Storm Data Source: User -provided custom storm data Rainfall Distribution Type: Type III Dimensionless Unit Hydrograph: <standard> WinTR-55, version 1.00.08 Page 1 9/14/2006 3:01:01 PM all saints 2006-004 existing Conditions Name of printed page file: TR20.out (continued) STORM 100-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area ID or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) 23.091 1.02 1.02 1.02 1.02 1.02 1.01 1.01 23.175 1.01 1.01 1.01 1.01 1.01 1.01 1.01 23.259 1.01 1.00 1.00 1.00 1.00 1.00 1.00 23.343 0.99 0.99 0.99 0.99 0.99 0.99 0.99 23.427 0.99 0.99 0.99 0.98 0.98 0.98 0.98 23.511 0.98 0.98 0.97 0.97 0.97 0.97 0.97 23.595 0.97 0.96 0.96 0.96 0.96 0.96 0.96 23.679 0.96 0.95 0.95 0.95 0.95 0.95 0.95 23.763 0.95 0.95 0.94 0.94 0.94 0.94 0.94 23.847 0.94 0.94 0.93 0.93 0.93 0.93 0.93 23.931 0.92 0.92 0.92 0.92 0.92 0.92 0.92 24.015 0.91 0.90 0.89 0.B6 0.83 0.78 0.72 24.099 0.66 0.59 0.52 0.45 0.39 0.33 0.28 24.183 0.24 0.20 0.17 0.14 0.12 0.10 0.09 24.267 0.08 0.06 0.05 STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow --- Reach Area ID or Amount Elevation Time Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) Tract 1 0.019 0.081 12.52 0.20 Line Rate (csm) 10.97 �„ act2 ? Start Time ------------ Flow Values @ time increment of 0.012 hr------------ (hr) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 12.312 0.06 0.07 0.08 0.10 0.11 0.12 0.14 12.396 0.15 0.16 0.17 0.18 0.18 0.19 0.20 12.480 0.20 0.20 0.20 0.20 0.20 0.20 0.20 12.564 0.20 0.20 0.19 0.19 0.19 0.19 0.18 WinTR-20 Version 1.0 Page 22 09/18/2006 13:59 all saints 2006-004 existing Conditions Line Start Time ------------ Flow Values @ time increment of 0.012 hr ----- (hr) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 12.648 0.18 0.18 0.18 0.17 0.17 0.17 12.732 0.17 0.17 0.17 0.17 0.17 0.17 12.816 0.17 0.17 0.17 0.17 0.17 0.17 12.900 0.16 0.16 0.16 0.16 0.16 0.16 12.984 0.16 0.16 0.16 0.16 0.16 0.16 13.068 0.15 0.15 0.15 0.15 0.15 0.15 13.152 0.15 0.15 0.15 0.15 0.15 0.15 13.236 0.15 0.15 0.15 0.15 0.15 0.15 13.320 0.15 0.15 0.15 0.15 0.15 0.15 13.404 0.15 0.15 0.15 0.15 0.15 0.15 13.488 0.15 0.15 0.15 0.15 0.15 0.15 13.572 0.15 0.15 0.15 0.15 0.15 0.15 WinTR-55, Version 1.00.08 Page 25 9/18/2006 0.17 0.17 0.16 0.16 0.16 0.15 0.15 0.15 0.15 0.15 0.15 0.15 all saints 2006-004 existing Conditions Name of printed page file: TR20.out (continued) STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area ID or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) 13.656 0.15 0.15 0.15 0.15 0.15 0.15 0.15 13.740 0.15 0.15 0.15 0.15 0.15 0.15 0.15 13.824 0.15 0.15 0.15 0.15 0.15 0.15 0.15 13.908 0.15 0.15 0.15 0.14 0.14 0.14 0.14 13.992 0.14 0.14 0.14 0.14 0.14 0.14 0.14 14.076 0.14 0.14 0.14 0.14 0.14 0.14 0.14 14.160 0.14 0.14 0.14 0.14 0.14 0.14 0.14 14.244 0.14 0.14 0.14 0.14 0.14 0.14 0.14 14.328 0.14 0.14 0.14 0.14 0.14 0.14 0.14 14.412 0.14 0.14 0.14 0.14 0.14 0.14 0.14 14.496 0.14 0.14 0.14 0.14 0.14 0.14 0.14 14.580 0.14 0.14 0.14 0.14 0.14 0.14 0.13 14.664 0.13 0.13 0.13 0.13 0.13 0.13 0.13 14.748 0.13 0.13 0.13 0.13 0.13 0.13 0.13 14.B32 0.13 0.13 0.13 0.13 0.13 0.13 0.13 14.916 0.13 0.13 0.13 0.13 0.13 0.13 0.13 15.000 0.13 0.13 0.13 0.13 0.13 0.13 0.13 15.084 0.13 0.13 0.13 0.13 0.13 0.13 0.13 15.168 0.13 0.13 0.13 0.13 0.13 0.12 0.12 15.252 0.12 0.12 0.12 0.12 0.12 0.12 0.12 15.336 0.12 0.12 0.12 0.12 0.12 0.12 0.12 15.420 0.12 0.12 0.12 0.12 0.12 0.12 0.12 15.504 0.12 0.12 0.12 0.12 0.12 0.12 0.12 15.588 0.12 0.12 0.11 0.11 0.11 0.11 0.11 15.672 0.11 0.11 0.11 0.11 0.11 0.11 0.11 15.756 0.11 0.11 0.11 0.11 0.11 0.11 0.11 15.640 0.11 0.11 0.11 0.11 0.11 0.11 0.11 15.924 0.11 0.11 0.10 0.10 0.10 0.10 0.10 16.008 0.10 0.10 0.10 0.10 0.10 0.10 0.10 16.092 0.10 0.10 0.10 0.10 0.10 0.10 0.10 16.176 0.10 0.10 0.10 0.10 0.10 0.10 0.10 16.260 0.10 0.10 0.10 0.10 0.10 0.10 0.10 16.344 0.10 0.10 0.10 0.10 0.10 0.10 0.09 16.428 0.09 0.09 0.09 0.09 0.09 0.09 0.09 16.512 0.09 0.09 0.09 0.09 0.09 0.09 0.09 16.596 0.09 0.09 0.09 0.09 0.09 0.09 0.09 16.680 0.09 0.09 0.09 0.09 0.09 0.09 0.09 16.764 0.09 0.09 0.09 0.09 0.09 0.09 0.09 16.848 0.09 0.09 0.09 0.09 0.09 0.09 0.09 WinTR-20 Version 1.0 Page 23 09/18/2006 13:59 all saints 2006-004 existing Conditions Line Start Time ------------ Flow Values @ time increment of 0.012 hr -- (hr) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 16.932 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.016 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.100 0.09 0.09 0.09 0.09 0.09 0.08 O.OB 17.184 0.08 0.00 0.08 0.08 0.08 0.08 0.08 17.268 0.OB 0.08 0.08 0.08 0.08 0.08 0.08 WinTR-55, Version 1.00.08 Page 26 9/18/2006 2:01:20 PM all saints 2006-004 existing Conditions Name of printed page file: TR20.out (continued) STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area ID or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) 17.352 0.08 0.08 0.08 0.08 0.08 0.08 0.08 17.436 0.08 0.08 0.08 0.08 0.08 0.08 0.08 17.520 0.08 0.08 0.06 0.08 0.08 0.08 0.08 17.604 0.0B 0.08 0.08 0.08 0.08 0.08 0.08 17.688 0.08 0.08 0.08 0.08 0.08 0.08 0.08 17.772 0.08 0.07 0.07 0.07 0.07 0.07 0.07 17.856 0.07 0.07 0.07 0.07 0.07 0.07 0.07 17.940 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.024 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.108 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.192 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.276 0.07 0.07 0.07 0.07 0.07 0.07 0.07 10.360 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.444 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.528 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.612 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.696 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.780 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.864 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.948 0.07 0.07 0.07 0.07 0.07 0.06 0.06 19.032 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.116 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.200 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.284 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.368 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.452 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.536 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.620 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.704 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.788 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.872 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.956 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.040 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.124 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.208 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.292 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.376 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.460 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.544 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.628 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.712 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.796 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.880 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.964 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.048 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.132 0.06 0.06 0.06 0.06 0.06 0.06 0.06 WinTR-20 Version 1.0 Page 24 09/18/2006 13:59 all saints 2006-004 existing Conditions Line Start Time ------------ Flow Values @ time increment of 0.012 hr------------ WinTR-55, Version 1.00.08 Page 27 9/18/2006 2:01:20 PM all saints 2006-004 existing Conditions Name of printed page file: TR20.out (continued) STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area ID or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) WinTR-20 Version 1.0 Page 25 09/18/2006 13:59 all saints 2006-004 existing Conditions Line Start Time ------------ Flow Values @ time increment of 0.012 hr------------ (hr) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 14.160 0.14 0.14 0.14 0.14 0.14 0.14 0.14 14.244 0.14 0.14 0.14 0.14 0.14 0.14 0.14 14.328 0.14 0.14 0.14 0.14 0.14 0.14 0.14 14.412 0.14 0.14 0.14 0.14 0.14 0.14 0.14 14.496 0.14 0.14 0.14 0.14 0.14 0.14 0.14 14.580 0.14 0.14 0.14 0.14 0.14 0.14 0.13 14.664 0.13 0.13 0.13 0.13 0.13 0.13 0.13 14.748 0.13 0.13 0.13 0.13 0.13 0.13 0.13 14.832 0.13 0.13 0.13 0.13 0.13 0.13 0.13 14.916 0.13 0.13 0.13 0.13 0.13 0.13 0.13 15.000 0.13 0.13 0.13 0.13 0.13 0.13 0.13 15.084 0.13 0.13 0.13 0.13 0.13 0.13 0.13 15.168 0.13 0.13 0.13 0.13 0.13 0.12 0.12 15.252 0.12 0.12 0.12 0.12 0.12 0.12 0.12 15.336 0.12 0.12 0.12 0.12 0.12 0.12 0.12 15.420 0.12 0.12 0.12 0.12 0.12 0.12 0.12 15.504 0.12 0.12 0.12 0.12 0.12 0.12 0.12 15.5BB 0.12 0.12 0.11 0.11 0.11 0.11 0.11 15.672 0.11 0.11 0.11 0.11 0.11 0.11 0.11 15.756 0.11 0.11 0.11 0.11 0.11 0.11 0.11 15.840 0.11 0.11 0.11 0.11 0.11 0.11 0.11 15.924 0.11 0.11 0.10 0.10 0.10 0.10 0.10 16.008 0.10 0.10 0.10 0.10 0.10 0.10 0.10 16.092 0.10 0.10 0.10 0.10 0.10 0.10 0.10 16.176 0.10 0.10 0.10 0.10 0.10 0.10 0.10 16.260 0.10 0.10 0.10 0.10 0.10 0.10 0.10 16.344 0.10 0.10 0.10 0.10 0.10 0.10 0.09 16.42B 0.09 0.09 0.09 0.09 0.09 0.09 0.09 16.512 0.09 0.09 0.09 0.09 0.09 0.09 0.09 16.596 0.09 0.09 0.09 0.09 0.09 0.09 0.09 16.680 0.09 0.09 0.09 0.09 0.09 0.09 0.09 16.764 0.09 0.09 0.09 0.09 0.09 0.09 0.09 16.848 0.09 0.09 0.09 0.09 0.09 0.09 0.09 16.932 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.016 0.09 0.09 0.09 0.09 0.09 0.09 0.09 17.100 0.09 0.09 0.09 0.09 0.09 0.08 0.08 17.184 0.08 0.08 0.08 0.08 0.08 0.08 0.08 17.268 0.08 0.08 0.08 0.08 0.08 0.08 0.08 17.352 0.08 0.08 0.08 0.08 0.08 0.08 0.08 17.436 0.08 0.08 0.08 0.08 0.08 0.08 0.08 17.520 0.08 0.08 0.08 0.08 0.08 0.08 0.08 17.604 0.08 0.08 0.08 0.08 0.08 0.08 0.08 17.688 0.08 0.08 0.08 0.08 0.08 0.08 0.08 17.772 0.08 0.07 0.07 0.07 0.07 0.07 0.07 17.856 0.07 0.07 0.07 0.07 0.07 0.07 0.07 WinTR-55, Version 1.00.08 Page 29 9/18/2006 2:01:20 PM all saints 2006-004 existing Conditions Name of printed page file: TR20.out (continuedl STORM 1-Yr Area or Drainage Rain Gage Runoff ------------ Peak Flow ------------ Reach Area ID or Amount Elevation Time Rate Rate Identifier (sq mi) Location (in) (ft) (hr) (cfs) (csm) 17.940 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.024 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.108 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.192 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.276 0.07 0.07 0.07 0.07 0.07 0.07 0.07 1B.360 0.07 0.07 0.07 0.07 0.07 0.07 0.07 WinTR-20 Version 1.0 Page 26 09/18/2006 13:59 all saints 2006-004 existing Conditions Line Start Time ------------ Flow Values @ time increment of 0.012 hr -- (hr) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) (cfs) 18.444 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.528 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.612 0.07 0.07 0.07 0.07 0.07 0.07 0.07 1B.696 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.7BO 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.864 0.07 0.07 0.07 0.07 0.07 0.07 0.07 18.948 0.07 0.07 0.07 0.07 0.07 0.06 0.06 19.032 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.116 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.200 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.284 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.368 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.452 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.536 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.620 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.704 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.788 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.872 0.06 0.06 0.06 0.06 0.06 0.06 0.06 19.956 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.040 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.124 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.208 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.292 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.376 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.460 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.544 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.628 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.712 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.796 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20,880 0.06 0.06 0.06 0.06 0.06 0.06 0.06 20.964 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.048 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.132 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.216 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.300 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.384 0.06 0.06 0.06 0.06 0.06 0.06 0.06 21.468 0.06 0.06 0.05 0.05 0.05 0.05 0.05 21.552 0.05 0.05 0.05 0.05 0.05 0.05 0.05 WinTR-55, Version 1.00.08 Page 30 9/18/2006 2:01:20 PM all saints 2006-004 existing Conditions Name of printed page file: TR20.out Area or Drainage Rain Gage Reach Area ID or Identifier (sq mi) Location 21.636 0.05 0.05 21.720 0.05 0.05 21.804 0.05 0.05 21.888 0.05 0.05 21.972 0.05 0.05 22.056 0.05 0.05 22.140 0.05 0.05 22.224 0.05 0.05 22.308 0.05 0.05 22.392 0.05 0.05 22.476 0.05 0.05 22.560 0.05 0.05 22.644 0.05 0.05 WinTR-20 Version 1.0 Area or Drainage Reach Area Alternate Identifier (sq mi) Tract 1 0.02 OUTLET 0.02 STORM 1-Yr (continued) Runoff ------------ Peak Flow ------------ Amount Elevation Time Rate Rate (in) (ft) (hr) (cfs) (csm) 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 Page 27 09/18/2006 13:59 all saints 2006-004 existing Conditions ----------- Peak Flow by Storm----------- 2-Yr 10-Yr 100-Yr 1-Yr (cfs) (cfs) (cfs) (cfs) (cfs) 12.8 34.1 62.1 0.2 12.8 34.1 62.1 0.2 WinTR-55, Version 1.00.08 Page 31 9/18/2006 2:01:20 PM ALL SAINTS EPISCOPAL CHURCH SAND INFILTRATION BASIN CALCULATIONS 05,# al-]202006 O&lvae &e'Av O&rFgn'wa KSMJ,pllc 388 McCotter Blvd, Havelock, NC 28532 Design Regulmrents seCimanl clianlim �t e]9 1. relnega area CRES-��nl�. �ef 00924%Pt ails Egre F �— e]9/5 @eaie9e Md(50Ff 594 dvaceam01310sgdleree 3.5 depth Brea 390egf9eve 1.5 Oepgi s-ndNlar e] 1B 1.5 % f Me de a (eaael 0 092/47918 %01 age aevelOpeO 4]919 dreirega eree Tan- b O W'7 39a tivdumeead(5a0CTM:rae =25'SP0,01']]'12 532293 gel • 7115.93498 wgCi-meervnll drain n2a ftaun 1.5 depth eree 390sQI0aoe 1" argon = 3993 Cuff 1.5 dePia 7.31B6143594 In M 91a 1' BveM b dnNn 9inw0a sans! PROVIDED REQUIRED PROVIDED REQUIRED SEDIMENT CHAMBER VOLUME TOTAL SEDIMENT SEDIMENT SEDIMENT SEDIMENT ELEV DELTAAREA LENGTH WIDTH DELTA ELEV AREA VOLUME VOLUME VOLUME SURFACE AREA SURFACE AREA + 20 _ /9 19.4 3.6 WS 85 23.6 20 0.6 2090.98 1700 1137.288 FREEBOARD (S4 F0 (Sp Ft) 19 2.4 82.6 17.6 0.4 1453.76 630.752 630.752 14 0.78 18.2 4.B 77.8 12.8 0.8 995.0 979.84 97984 17.7 3 74A BA 0.5 733.04 432.22 43222 17.1 3.6 71.2 6.2 0.6 "1." 352.344 2941W 16.2 5.4 65.8 1 0.9 85.8 228.258 157.5 3 02 2495.2 594 1453.76 396 REOUIRD PROVIDED REQUIRD PROVIDED PROVIDED REQUIRED SAND INFILTRATION CHAMBER VOLUME TOTAL INFILTRATION INFILTRATION INFILTRATION INFILTRATION TOTAL STORMWATER STORMWATER ELEV DELTAAREA LENGTH WIDTH DELTA ELEV AREA VOLUME VOLUME VOLUME SURFACEAREA SURFACEAREA STORAGE STORAGE STORAGE 20 88.6 23.6 2090.% (SR F0 (SQ Ft) 10.4 38 85 20 0.8 1700 1137.2W FREEBOARD 19 18.2 2d 4 B US T7.8 17S 12.8 0.4 0.8 145328 W&U 830352 979.84 630,752 979.84 6W.752 17.7 3 74.8 9.8 0.5 733.04 432.22 432.22 17.1 36 71.2 6.2 0.6 "1A4 352.3u 294.888 18.2 54 65.8 1 0.9 65.8 228.258 157.5 .02 249 .2 94 830.]52 396 TOTAL(CuPt) 7621.4 4990.4 ]521.404 4MA 3993 INFILTRATION SITE VISIT REQUEST Name of the Project : d Lt_ 5A t U 1-`� 6-P I -5c oP-a L-- c t-ti rz c ry Location (attach a clear vicinity map): Street address, SR number, community, etc. C' Directions from the nearest major intersection: 50UiV- ( "/z M tLci 4� t*U3'1 -70 Owner/ plicant' me: Suc�actatr� PC Consultant Name: ISvc )ct.4A4PI. PC Consultant Contact Information: )4 °J— S R 03 ( Ztia.) _ Phone, fax, email, etc. Existing ground elev. @basin/trench= SHWT elev.= SHWT plus 2' (max. bottom elev.)= Date/Time of Soils Investigation : #1 . #2 #3 #4 #5 #6 #7 #8 64 f . 36 �, ,..,......,, ram,,....,,,,..,.... _. All proposed infiltration areas and existing, active utility lines located within the proposed basin/trench must be marked and flagged. If these areas are not flagged, the Soils Scientist reserves the right to decline to do the investigation. If the proposed infiltration system will be located in an area of existing pavement and there is no open area nearby, equipment capable of breaking through the impervious layer must be provided. The soils investigation does not take the place of a soils report prepared by an appropriate professional. The Soils Scientist will only verify the soil conditions that are reported in the Soils Report, and make a determination as to the suitability of the site to meet the infiltration design requirements under NCAC 2H.1000,.and assumes no liability should the system fail. THIS w rrsc4 WC. N 0. OIG 01jt TtS r 16. •. 0 S"RAGE BUILD. CH • • 4, er T.. 10 ' fi t ay a b JaP �� • ro.o n � • 1 e.� • 16.a + f .••».1'" m i "' .9 ! t • 1 A �b I1r Vt DRAGE BWLD. • 19.J I �I rap 727'PO 32 R7 •3____________ _ _E73,OB' •10.0 D.0 1 NAIL •1E.] •19.1 •,9.3 ___,__; A>r \ , PER B iIAND S SHELTC91 t - J II I ' .4V 0. .0 0 It9.9 .•19.E i.PRAGE BUILD .%.. . RESER LIFE ESTATE AREA IH P �4 Rb Sy /7• �� -1 19.0 J PER GREEMENT r 10.4 1.153 ACRESMAW t , g „� ,taS ---- J Bu D. 20.4 1 V ,ram \��L R �jiNGLC TORT VELIING f A•y - 0 BLOCK ATION I • 19.E r►�, i b�1rRr r. _ i Jot 1 / i br•TI'V K • AVi r.y `� •ID.1 r + am 1(g 1 •19.9 r i I 1 { 3' I YI7.3IPE\ •19.2E111STIMG DITCH LOV _ • 19.3 .19.E/y�.D C N ,y (J •19, GRA V[L 10.4 .12.3 • 1 D.6 E' VINYL PIPE N24YPwa r2 1 INVERT 17.]' C� ' 20 19-2 0 1� �1 f'M� .SveSw..11�/Q� LSt•14f•S/G� tml A ltto &ILI &J C. L4iIL KS Mj . PLLC 388 MCC OTTFR HIND HAVI-.T.O(:K,N(-. 29532 252-444 5765 252�349-5803 FACRIMILE,rItANSMI-I"J'Al. SHEET FROM 0 Sue sayger'PE IWIT (;OMPANY: DNFR 8/23/2006 '101 A I. NO. Ojm PACT"S I N(:I.L;I)IN(, (OVER: 910-350-2004 2 NIONk NUN11%kil WIMIMIL 910-350 2004 RII: YOUK RIATTIENCL NLIMFIRR: All Saints F.piqcoTvALMCCabeRd ❑ IIRUISN'r X VOK RI:Vll:.W❑ COMMENT X III.CAS14 AITLY ❑ VEFASE RECYfAX. vince.111, Thanks for con -Ling out to the site and helping nic with the conditions. AswedLscii5sc(l,here isacopy (If the site. I marked I lie areas where wr. look the tests. I am playing tclq)honc tag with Paul, but I an, na"Vilip, forward Willi all L11filtrItiOn area in the arina,d i he third tCJ%. Will you pk-.aqe forward me a copy Or the test result,?? Tlialiks again, S Sue S 'ayger'pl-" 40 KSMJ,Pllc 388 McCotter Blvd Havelock, NC 28532 10'd 60:cz go-zz-Brl I N O _ a `m o ER G Df CH M 51CRAGE BUILD. " 7d� -1 •t0.0 y � I •1 .5� 0. •10.3 � � • I"�.r V�D AGE BUILD. AwAmr ----------- i±73.OB' •1e.1 - -------Amw �IR13AN0 S C SHELtOR ; I 1 f I +� •1B.s •10.0 ' •IBs _ _ 1 •SrAB OV-(JB((1CIB.1 /QVII.IPAGI BUILD. RESER LIFE ESTATE AREA ;rn y Ia SOF7 PER GREEMENT ; r 10.4 1.173 ACRES j Imo STUB C DU D. 20'4i�r`$yfa_ --V GLE TORY- VELLING I I •121 A•�� ��RRr 0 BLOCK TION 1gvy lai 1 � I •10.3 •19.9 •1i 03y� 0.0 J9 • 9.17 EKISTIt/G DIICN lOV 0 C GOA VE l 10.3' • 10.5 , 10.e INVRT l7 YD E. N 34' 3 .I ID T° I •10.7 ?� N .O a L o K ral'17r` V rn LpCAt'1 e. < < -I ReS r U 11-13-06 09c00 P.O1 KSMJ,PLLC F ACSIMI LE TRA NSMI'ITAL SHV.GT .L11, flillM __ (::uneron Wclver Sue SaY*T CI IMI•AN) ❑A'1'1: DNh'R ,1 .xpress Pcmrirdng 7/13/2006 p.i\ NI Ai14vH 'It'i I'•\I. NU I1P IIAGP,p IN':l. lI?INLI I'i Nlllt: 910 350-21x14 5 rI IUNP. NL'MhI(I:. SF.NI ❑ill's IIP.P I+N V.NIai NC MIMR: \'I AI it KI I FRIlNIA1 N1'M111(It: lixpress permit review epplicit6oll ❑ I!IiC•P.IN V XX I't.I It It 1.1:'11i It'- xx 1`1.1:.AS I.: t",I IMM1:Is I' ❑ PI.FASI: 11IU'IN ❑ I'LI[A G.; lw.,:vcl.P. NW'IN/U(IDIMI Camv Rlll, I'lcnsc give me a call and lcr mc. know it all is nk and when .ve could nlcCl. 'Thank,, Luc $,ygclj i ASAV 38b' Mc'C nllet B/i d Havelock, NC 252-34.9 :5)803 Ju1-13-06 09:00 P.02 v 50sA NCDEM a.l) North Carolina Department of Environment and Natural esources 127 Cardinal Drive, Wilmington NC 284J5 (910) 796-7307 FAX (910) 350.20D4 Request for Express Permit Review L .- 3 FILL-IN all information below :and CHECK required Permit(s). FAX or email to Cameron. weave ncmail.net along with a narrative and vicinity man of the project location. Projects must be submitted by 9:00 A.M. of the review date, unless prior arrangements are made. APPLICANT Name ALL SQIr✓i3 Company �-F�i5cuP4l_ G t*�fZclt Address �� 7J County City/State j 1 J2 E ""' o "-Zip Phone Z k -?- - v -)O D Fax Z 4 -4 - 5 & 7 Email / PROJECT Name PROJECT SYSTEM(S)TRIBUTARY TO HULL_ 5 w4rAV� (STREAM NAME) w ri t 1Z. n A v'__ RIVER BASIN ENGINEER/CONSULTANT _ sv 5n,J `J A C. t az, IBC Company ►tSr� j f'��G t Address 3 L3t3 & ty City/State t- � k _Zip Coun Phone .9 5 2 . 3,�i 0 - 5 it 0 3 Fax i"yr Jr-t'f - 5 7 r 5 Email t+-e r5 c- (2 5 A Y4 rz r4,,) State or National Environmental Policy Act (SEPA, NEPA) - EA or EIS Required ❑ Yes ❑ No ❑ STREAM ORIGIN Determination; # of stream calls; Stream Name I+01-1, -6"A.-%P Jul-13-06 09:00 P-03 eSTORMWATER e'Low Density n High Density -Detention Pond ❑ High Density -Other Wetlands MUST be addressed below ❑ Low Clensity-Curb & Gutter ❑ High Density -Infiltration ❑ Off Site ❑ COASTAL ❑ Excavation & Fill [] Bridges & Culverts ❑ Structures Information MANAGEMENT [I Upland Development ❑ Marina Development ❑Urban Waterfront --------- -------------- 8 LAND QUALITY 12 Erosion and Sedimentation Control Plan with I 3 acres to be disturbed. WETLANDS (401) Wetlands on Property ❑ Yes ❑ No Isolated Wetlands on Property ❑ yes ❑ No Check all that apply Wetlands Will Be Impacted 17Yes ONO Wetland Impacts: `�— Acre(s) j � y Wetlands Delineation has beten completed ❑ Yes fia No ❑ Buffers Impacted: Acre(s) 4COEApproval of Delineation completed 0Yes 0NO n in process w/USACOE ❑Yes ❑No I Permit received from USACE ❑Yes (3No ition required ❑Yes Ll No If Yes, 0 Regular ❑ Express Additional fees, not to exceed 60% of the original Express Review permit application fee, may be charged for subsequent reviews due to the insufficiency of the permit applications. SUBMITTAL DATES: SW CAMA LQS _ 401 For DENR use only Fee Split for multiple permits: Total Fee Amount $ Jul-13-06 09:00 P_O4 All Saints F.nueonal Church McCabe Road Town ol'Morehead City, North Carolina Express Permit A III�;ation.Review Narrutiyc This express permit review application is for the construction of" a new, slab on - grade church facility, All Saints Episcopal Church on an 11.9-arce parcel, located in the Town of Morehead City, Carteret County. Zoned residential (church facility is a permitted use), the parcel fronts McCabe Road (south ol'NC I lighway 70) and borders on Iluff Swamp Creek which ultimately drains into the White (yak River. The existing topography of the entire parcel is flat, with the minimal grade (less than one percent) draining towards the creek. The northern boundary is a ditch line which also drains to the creek. Regarding Land Quality and Erosion and Sediment Control, approximately ten percent of the site will he disturbed. Within the ten percent, the site will remain primarily flat. 'There will be no disturbance within 300 feet of the creek. To contain sediment on the site we will use sediment fence along the limits of disturbance and a construction entrance at McCabe Road. Regarding storm water,.the project is being submitted as a low density design. I'he percentage of proposal imperviousness, including building area (11,032 sy it) and paved area (26,963 sq Il)-total 37,995 sy 0, or 7.3 % of the total 11.9 acres_ Additionally, the design includes no discrete collection system, roof drains will splash out on grade and all paved surfaces will sheet flow to grassed surfaces. The existing ditch will remain in place within the 30-foot vegetative butler. Regarding LAMA, I lull Swamp Cn:ck is classified as a C class water_ There arc no applicable ADCs associated with the parcel. No disturbance, grading or amstruction will take place within 300 feet of the creek. We see no applicable C:AMA issues. 'There are no C;AMA jurisdictional wetlands within the scope of this project. WILDWOOD N/C W4 y O SITE N.C.S.R. 1147 N.C. HY. 24 (McCABE ROAD) S.R. 1268 , 1 S.R. 1297 VICINITY SKETCH L J w I 0 m 0 0 0 a 0 SOS I D: 610366 Date Filed: 6/24/200312:01:00 PM Elaine F. Marshall North Carolina Secretary of State C200316700044 State of North Carolina Department of the Secretary of State ARTICLES OF INCORPORATION OF ALL SAINTS CHURCH AMIA, INC. A Nonprofit Corporation This is to certify that we, the undersigned, being of the age of eighteen (18) years or more, do hereby make and acknowledge these Articles of Incorporation for the purpose of forming a nonprofit Corporation under and by virtue of the laws of the State of North Carolina, as contained in Chapter 55A of the General Statutes of North Carolina, entitled "Nonprofit Corporation Act", and the several amendments thereto. I The name of the Corporation is All Saints Church AMIA, Inc. II The purposes for which the Corporation is organized are exclusively religious, charitable, and education within the meaning of Section 501(c)(3) of the Internal Revenue Code of 1986 or the corresponding provision of any future United 'States Internal Revenue,law. The purposes are as follows: 1. To provide for and support public worship of God. -2- 2. To carry out all proper religious activities in furtherance of the Gospel of Jesus Christ in affiliation with and according to the Solemn Declaration of the Anglican Mission in America. 3. Any other lawful purpose .in furtherance of purposes 1 and 2. III The period of existence of this Corporation shall be perpetual. IV The Corporation shall have one (1) class of membership. Members shall have voting rights as provided by the Bylaws. V The affairs of the Corporation shall be run by its Board of Directors, which shall be called a vestry, which shall consist of not less than three (3) nor more than fifteen (15) Directors, elected at the annual meeting of :he Corporation, and in accordance with the Bylaws of this Corporation. VI No fees, bonuses, commissr.ons or other payments shall be made to or inure to the benefit of any officer, director, vestry person, or member.• of the Corporation. No part of the net earnings of the Corporation shall inure to the benefit of, or be distributable to, its members, directors, vestry oersons, officers, or other private -3- persons, except that the Corporation shall be authorized and empowered to pay reasonable compensation for services rendered and to make payments and distributions in furtherance of purposes set forth in these Articles of Incorporation. No substantial part of the activities of the Corporation shall be the carrying on of propaganda or otherwise attempting to influence legislation, and the Corporation shall not participate in or intervene in (including the publishing or distribution of statements) any political campaign on behalf of or in opposition to any candidate for public office. VII Upon the dissolution of this Corporation, the Board of Directors (Vestry) shall, after paying or making provision for the payment of all of the liabilities of the Corporation, dispose of all of the assets of the Corporation exclusively for the purposes of the Corporation in such manner, or to such organization or organizations organized and operated exclusively for religious, charitable, or educational purposes as shall at the time qualify as an exempt organization or organizations under Section 501(c)(3) of the Code as the Board of Directors shall determine, or to federal, state or local governments to be used exclusively for public purposes. Any -such assets not so disposed of shall be disposed of by the Superior Court of the County in which the principal office -4- of the Corporation is then located, exclusively for such purposes or to such organizations, as such court shall determine, which are organized and operated exclusively for such purposes, or to such governments for such purposes. VIII In addition to the powers granted corporations under the laws of the State of North Carolina, this Corporation shall have full power and authority to: (a) Accept by gift, grant, devise, bequest, purchase or otherwise and to hold for investment or in trust and to sell, donate or otherwise dispose of any money or real or personal property for its own use and for the purpose of obtaining income from accumulated funds, or for the purpose of accomplishing any of the objects set forth in this charter. (b) Lease, rent, purchase, own, operate, develop and encumber real estate or personal property for its own use, for the purpose of obtaining income from accumulated funds, or for the purpose of accomplishing any of the objects set forth in these Articles of Incorporation. (c) Employ such agents and employees and pay such expenses as may be necessary for the operation of the affairs of the Corpora- tion. Ix Notwithstanding any other provision of these Articles of -5- Incorporation, this.Corporation shall not carry on any activities not permitted to be carried on by an organization exempt from Federal Income Tax under Section 501(c)(3) of the Internal Revenue Code of 1986 or the corresponding provisions,of any future United States Internal Revenue Law. X Directors (Vestry persons) shall have no personal liability for monetary damages arising out of an action whether by or in the right of the corporation or otherwise for any breach of duty as a director or vestry person except as provided in Section 55A-2- 02 (b) (4) . XI The address of the initial registered office and principal office of this Corporation is: 2012 Evans Street, Morehead City, Carteret County, North Carolina 28557, and the name of the initial registered agent of such address is John H. Grayson. XII The number of persons consisting of the initial Board of Directors (Vestry) is one and the name and Post Office address of the member constituting such initial Board of Directors (Vestry) is: NAME ADDRESS Richard H. Wray, III 4219 Sound Drive Morehead City, NC 28557 0 It is understood that the initial Board of Directors will be succeeded by the leadership body of the Church upon election pursuant to the Bylaws of the Church. The name and address of the original incorporator is as follows: NAME ADDRESS Nelson W. Taylor, III 610 Arendell Street Morehead City, NC 28557 In testimony whereof, I have hereunto set my hand and seal this the 11" day June, 2003. Nelson W. Taylor, PII,'Incorporator STATE OF NORTH CAROLINA COUNTY OF CARTERET This is to certify that on the 11`h day of June, 2003, before me, a Notary Public, personally appeared Nelson W. Taylor, III, who I am satisfied is the person named in and who executed the foregoing Articles of Incorporation of All Saints Church AMIA, Inc.; and I have first made known to him the contents thereof, he did acknowledge that he signed and delivered the same as his voluntary act and deed for the purposes and uses therein expressed. Witness my hand and notarial seal, this the 11`h day of June, 2003. My commission expires: �u,,,,,,,,,,,,��� July 27„ 2007 SPF,1',<t-,jNotary Pub is �QTARy %E3L\G . 9OOZ/61/O1"'Q--JOAUIWL=nWSZ=s7B£b6£8'9L-=uo178ZZZbL 6b0'L-=9 �T auoZ win si uolp:)afoad alBuejpena (JN) plal;sueW s9sn (b8S9M/E8C1VN) M,9E'OS o9L 'N,ES'bb obE ? w Gb' 0 96' 0 LZ' 0 WO 60' 0 0 WA G'0 1'0 f'0 Z'0 L'0 0 13o I aged drIN odos (DR) playsueK Sf)Sfl - auoZodo'£ PRELIMINARY LAND & SOILS MAP OF THE ALL SAINTS EPISCOPAL CHURCH TRACT (-12 acs, north portion) FOR POTENTIAL 404 WETLAND AREAS vs UPLAND AREAS Morehead City West Area - Morehead Township - Carteret County - North Carolina SCALE: 1 Inch = 200 Feet (all lines paced & approximate) SEPTEMBER - 2006 UTM: 18 331665 E 3845788N x isting f wildi ngs \\� o DBvel m Limits o 'm I Existing Bullrings POTENTIAL UPLAND AREAS These areas have non-hydric soil 8 vegetative indicators. Should not come under USACOE-EPA nor NCDENR-DWO 404 Wetlands jurisdictions. POTENTIAL 404 WETLAND AREAS These areas have hydric soil, vegetative, and/or hydrology indicators. These wetland areas have the potential to be defined as jurisdictional 404 Wetlands under USACOE-EPA and NCDENR-DWO jurisdictions. Land Management Group, Inc. PRELIMINARY LAND & SOILS MAP OF THE ALL SAINTS EPISCOPAL CHURCH TRACT (-12 acs, north portion) FOR POTENTIAL 404 WETLAND AREAS vs UPLAND AREAS Morehead City West Area - Morehead Township - Carteret County - North Carolina SCALE: 1 Inch = 200 Feet (all lines paced & approximate) SEPTEMBER - 2006 UTM: 18 331565 E 3845788N f xisting Buildings Limits Existing Buildings oCA 0 510 9 POTENTIAL UPLAND AREAS These areas have non-hydric soil & vegetative indicators. Should not come under USACOE-EPA nor NCDENR-DWO 404 Wetlands jurisdictions. POTENTIAL 404 WETLAND AREAS These areas have hydric soil, vegetative, and/or hydrology indicators. These wetland areas have the potential to be defined as jurisdictional 404 Wetlands under USACOE-EPA and NCDENR-DWO jurisdictions. Land Management Group, Inc. PRELIMINARY LAND & SOILS MAP OF THE ALL SAINTS EPISCOPAL CHURCH TRACT (-12 acs, north portion) FOR POTENTIAL 404 WETLAND AREAS vs UPLAND AREAS Morehead City West Area - Morehead Township - Carteret County - North Carolina SCALE: 1 Inch = 200 Feet (all lines paced & approximate) SEPTEMBER - 2006 UTM: 18 331565 E 3845788N L M isMq Buildings Existing Buildings 7 Development Limits lil s 0L � 0 2p06 1►] POTENTIAL UPLAND AREAS These areas have non-hydric soil & vegetative indicators. Should not come under USACOE-EPA nor NCDENR-DWQ 404 Wetlands jurisdictions. POTENTIAL 404 WETLAND AREAS These areas have hydric soil, vegetative, and/or hydrology indicators. These wetland areas have the potential to be defined as jurisdictional 404 Wetlands under USACOE-EPA and NCDENR-DWQ jurisdictions. Land Management Group, Inc. TopoZone - USGS Mansfield (NC) Topo Map Page 1 of 1 • x _ ✓ - l Ole G; rj i b \: M* 0 0.1 0.2 0.3 0.4 0.5 km 0 0.09 0.18 0.27 0.36 0.41 mi UTM 18 331565E 3845788N (NAD27) USGS Mansfield (NC) Quadrangle M=-9.842 Projection is UTM Zone 18 NAD83 Datum G=-1.049 http://www.topozone.com/print.asp?lat=34.7421 &Ion=-76.83992&s=24&u=4&layer-DR... 9/29/2006 cn 4PR ey U) ` m l 0 o v or o n { L \