Loading...
HomeMy WebLinkAboutNC0032867_Renewal (Application)_20230308NPDES APPLICATION - FORM D For privately -owned treatment systems treating 100% domestic wastewaters <1.0 MGD Mail the complete Water Quality to: RECEIVED N. C. DENR /Division of Water Quality /NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit C0032867 MAR 0 8 m3 If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Othen sQ, pigIT(TtOW N P'D E S L Contact Information: Owner Name MLNC Acquisition, LLC c/o Insignia Partners, LLC Facility Name Kings Mountain Travel Plaza Mailing Address 110 East Court Street, Suite 203 City Greenville State / Zip Code SC 29601 Telephone Number 864.438.2071 Fax Number n/a e-mail Address info@insignispartners.com 2. Location of facility producing discharge: Check here if same address as above ❑ Street Address or State Road 400 Dixon School Road City Kings Mountain State / Zip Code NC 28086 County Cleveland 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name MLNC Acquisition, LLC c/o Insignis Partners, LLC Mailing Address 110 East Court Street, Suite 203 City Greenville State / Zip Code SC 29601 Telephone Number 864.438.2071 Fax Number n/a e-mail Address info@insignispartners.com 1 of 4 Farm-D 11112 NPDES APPLICATION - FORM D For privately -owned treatment systems treating 100% domestic wastewaters <1.0 MGD 4. Description of wastewater: Facilitv Generating Wastewater(check all that applyr Industrial ❑ Number of Employees Commercial ® Number of Employees Residential ❑ Number of Homes School ❑ Number of Students/Staff Other ❑ Explain: Describe the source(s) of wastewater (example: subdivision, mobile home park, shopping centers, restaurants, etc.): Interstate truck stop with low to moderate activity. Activities include small food service S hours per day, one men and one ladies restrooms, shower facilities with low use. These sources treated by small package plant. Stormwater runoff from diesel fuel dispensing area diverted to an oil/water separator before discharge to Number of persons served: approx 50 per day average - food service approx 20 per day S. Type of collection system ® Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points two Outfall Identification number(s) 001,002 Is the outfall equipped with a diffuser? ❑ Yes ® No 7. Name of receiving stream(s) (NEW applicants: Provide a map showing the exact location of each outfall): 001 Dixon Branch, 002 Kings Creek S. Frequency of Discharge: ® Continuous Outfall 001 ® Intermittent Outfall 002 If intermittent: Days per week discharge occurs: <1 for 002 Duration: storm event dependent 9. Describe the treatment system List all installed components, including capacities, provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet ofpaper. 2 of 4 Form-D 11/12 NPDES APPLICATION - FORM D For privately -owned treatment systems treating 100% domestic wastewaters <1.0 MGD See Separate sheet for 9. Equipment List RECEIVED MAR 0 S �323 N( r,)EQ/DWR/NPDES 3 of 4 Form-D 11/12 NPDES APPLICATION - FORM D For privately -owned treatment systems treating 100% domestic wastewaters <1.0 MGD 10. Flow Information: Treatment Plant Design flow 0.015 MGD Annual Average daily flow 0.002 MGD (for the previous 3 years) Maximum daily flow 0.02 MGD (for the previous 3 years) 11. Is this facility located on Indian country? ❑ yes ® No 12. Effluent Data MEW APPLICANTS: Provide data for the parameters listed. Fecal Colifonn, Temperature and pH shall be grab samples, for all other parameters 24-hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. RENEWAL APPLICANTS: Provide the highest single reading (Daily Maximum) and Monthly Average over the past 36 months for parameters currently in your permit. Mark other parameters "N/A". Parameter Daily Maximum Max Monthly Average Units of Measurement Biochemical Oxygen Demand (BOD5) 55 18 mg/1 Fecal Coliform 330 98.7 #/ml Total Suspended Solids 13.2 6.97 mg/l pH 8.2 N/A su NH3N 3.26 0.65 mg/l Oil/Grease 11.6 2.9 mg/l 13. List all permits, construction approvals and/or applications: Type Hazardous Waste (RCRA) UIC (SDWA) NPDES PSD (CAA) Non -attainment program (CAA) 14. APPLICANT Permit Number NCO032867 Type NESHAPS (CAA) Ocean Dumping (MPRSA) Dredge or fill (Section 404 or CWA) Other Permit Number I certify that I am familiar with the information contained in the application and that to the beat of my knowledge and belief such information is true, complete, and accurate. Paul Sparks Managing Partner Printed name of Person Signing Title of Applicant March 3, 2023 Date North Carolina General Statute 143-215.6 (b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record, repot, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, fora similar offense.) 4 of 4 Form-D 11/12 Attachment to NPDES permit renewal KMTP February 28, 2023 Treatment plant description Section 9. Two 900 gal septic tanks - concrete construction One splitter box for flow diversion with bar screen One 7,500 gal aeration basin with integral bar screen, space for two positive displacement blowers with 3 HP motor, piping for coarse bubble aeration, clarifier with RAS and skimmer piping, contact chamber One 10,000 gal aeration basin with integral bar screen, space for two positive displacement blowers with 3 HP motor, piping for coarse bubble aeration, clarifier with RAS and skimmer piping, contact chamber Portable sump pump for waste activated sludge One 900 gal chlorine contact chamber - with tablet feeders for disinfection and de -chlorination One 900 gal aerobic digester - a septic tank of concrete construction One 900 gal holding tank - a septic tank of concrete construction One Flow measuring system comprised of a 22-1/2 degree v-notch weir and a Stevens Total Flow Meter with totalizer and chart recorder The septic tanks of concrete construction are piped in series. They are part of the original construction and are now approximately 45 years old and were originally set at the influent for oil/grease removal. The aeration basins and clarifiers are of steel construction and are a typical package plant design. The contact chambers listed were originally disinfection tanks with no means of de - chlorination and were augmented at some time in the past with the newer 900 gal chamber for tablet feed chlorination/dechlorination. The 900 gal aerobic digester has an air supply from one of the aeration blowers. Wasted sludge is manually pumped to this unit if needed. This unit has been used infrequently in the past. Estimate of removal for the pollutants are: BOD 90 to 95% Nitrogen 40 to 60% TSS 90 to 95% The adjustment of pH for the aeration basins is through manual addition of pelletized soda ash or lime. The disinfection tablets are sodium hypochlorite and a sulfide for de -chlorination. Waste sludge from the treatment plant and contents of the septic tanks has been handled in the past through pumping and removal by Wesson Septic Tank Service with disposal at the Cliffside Sanitary District in Rutherford County. Outfall 002 for this permit has stormwater treatment from the runoff area at the diesel dispensers via an oil/water separator. The oil/water separator is approximately 95 to 98% effective in removal of oil/grease and TSS. Effluent quality comments: Data provided in the tables are the maximum daily value and the monthly average that was the highest value for the three years 2020, 2021 and 2022. The highest BOD readings reported (17.75 monthly average and maximum daily of 54.9 mg/1) was in January 2022 and it is believed to be the result of excess sodium sulfite in the effluent caused by poor quality de -chlorination tablets and not a result of poor biological treatment. The next highest daily and monthly average for BOD were 11.95 mg/l for monthly and 27.5 mg/1 for daily maximum occurring October 2020. The typical BOD concentration in the effluent is much lower than these highest concentrations. Latitude: 35"11'37" (001) LFaciJity 35°u'49.4" (002) NCO032867 on Longitude: 81°22'44" (001) 81-22'12.6" (002) Kings Mountain 1:24000 Receiving Stream: Dixon Branch (001) Travel Plaza Kings Creek (002) North Cleveland County Cnhhasin: 30805 Stream Class: C (both streams)