HomeMy WebLinkAboutNC0021181_Compliance Evaluation Inspection_20230306ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Bill Carroll, Public Works Director City of Belmont Post Office Box 431 Belmont, NC 28012 SUBJECT: Notice of Deficiency Compliance Evaluation Inspection City of Belmont WWTP NPDES Permit No. NCO021187 Gaston County Tracking #: NOD-2022-PC-0060 Dear Mr. Carroll: NORTH CAROLINA Environmental Quality March 6, 2023 Enclosed is a copy of the Compliance Evaluation Inspection (CEI) Report for the inspection conducted at the subject facility on February 28, 2023, by Mr. Wes Bell of this Office. Please advise the facility's Operator -in -Responsible Charge (ORC) of our findings by forwarding the enclosed report. Although the ORC and staff have initiated commendable operational efforts, this report is being issued as a Notice of Deficiency (NOD) due to the City's failure to properly operate and maintain WWTP which is a violation of the subject NPDES Permit and North Carolina General Statute (G.S.) 143-215.1. Specifically, the City has not adequately maintained wastewater solids (bio-solids disposal, etc.) to enable proper operation of the treatment processes as discussed further in the Aeration Basin, Secondary Clarifier and Disinfection -Gas Sections in the attached report. Please note that G.S. 143-215.6A provides for a civil penalty of not more than twenty-five thousand dollars ($25,000.00), or twenty-five thousand dollars ($25,000.00) per day when the violation is of a continuing nature, against any person who violates or fails to act in accordance with the terms, conditions, or requirements of any permit issued pursuant to G.S. 143-215.1. Penalties may also be assessed for any damage to surface waters of the State that may result from the violation. North Carolina Department of Environmental Quality I Division of Water Resources Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 704.663.1699 It is requested that a written response be submitted to this Office by March 27, 2023, detailing the City's actions to address the violation including evaluations of alternate disposal options (portable belt press/landfill, etc.) to ensure the WWTP is properly operated and maintained at all times. In responding, please address your comments to the attention of Mr. Wes Bell. Should you have any questions concerning this Notice, please do not hesitate to contact Mr. Bell at (704) 235-2192 or at wes.bell&ncdenr. gov. Enclosure: Inspection Report Cc: NPDES Program Files - Laserfiche Sincerely, Docu Signed by: 444W N P44,ft F161FB69A2D84A3... Andrew H. Pitner, P.G. Assistant Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ North Carolina Department of Environmental Quality [ Division of Water Resources Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 704.663.1699 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO021181 111 121 23/02/28 I17 18 LC] I 19 I s I 201 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 2.0 701d I 71 I„ I 72 I r., I 71 I 74 79 I I I I I I I80 L—I ty L-1 I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09:05AM 23/02/28 19/12/01 Belmont WWTP 298 Parkdale Rd Exit Time/Date Permit Expiration Date Belmont NC 28012 12:30PM 23/02/28 24/06/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Tanya S Carter/ORC/704-825-3791/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Barry L Webb,PO Box 431 Belmont NC 280120431/Interim City Manager/704-825-5586/7048250514 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran 0 Sludge Handling Dispo: Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Wes Bell signed by: DWR/MRO WQ/704-663-1699 Ext.2192/ 3/3/2023 Be& E�Docu`,','�96D90=437 ... Signature of Mana @000PRdbyiewer Agency/Office/Phone and Fax Numbers Date Andrew Pitne X"{'" H P4"R/MRO WQ/704-663-1699 Ext.2180/ 3/6/2023 F161FB69A2D84A3... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NC0021181 I11 12I 23/02/28 117 18 i c i (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Influent Sampling Section cont'd: The normal influent sampling location does not include side streams; however, the temporary sampling location may include decant from the aerobic digesters due to the bar screen/grit chamber bypass. The ORC and staff must ensure no side streams are discharged during long term sampling events (Headworks development). Operation & Maintenance Section cont'd: The ORC and staff have initiated commendable efforts to operate the wastewater plant with a high solids inventory due to the delays associated with the weather and land application events. Evidence of high solids inventory were observed in the aeration basin (high settleability tests) and secondary clarifiers (high sludge blankets) along with high sludge levels in the chlorine contact basin as a result of the solids carry-over from the secondaries. Please be advised that the subject permit requires the permittee to properly operate and maintain all facilities and systems of treatment at all times [Permit Condition Reference: Part II, Section C(2) Proper Operation & Maintenance]. Page# Permit: NCO021181 Owner -Facility: Belmont WWTP Inspection Date: 02/28/2023 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ■ ❑ application? Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ■ ❑ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: The City implements a Division -approved Industrial Pretreatment Program. The last compliance evaluation inspection at this facility was performed by DWR staff on 2/8/2021. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ■ ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ■ ❑ ❑ ❑ operator on each shift? Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility ■ ❑ ❑ ❑ classification? Is a copy of the current NPDES permit available on site? ■ ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ■ ❑ ❑ ❑ Page# 3 Permit: NCO021181 Inspection Date: 02/28/2023 Owner -Facility: Belmont WWTP Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Comment: The records reviewed durinq the inspection were organized and well maintained. Discharge Monitoring Reports (eDMRs) were reviewed from February 2022 through January 2023. Effluent permit limit violations were reported in June 2022 (total residual chlorine), August 2022 (chronic toxicity failure) and January 2023 (fecal coliform). The above -noted violations will be separately addressed by the Division through the issuances of either Notice of Violations (NOVs) or NOV/civil penalty assessments. ORC visitation log, operation & maintenance records and process control measurements were beina DroDerIv documented and maintained on -site. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? ■ ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑ # Is the facility using a contract lab? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ■ ❑ ❑ ❑ degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ■ ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ ■ ❑ Comment: Pace Analytical Services has been contracted to perform Influent and effluent (including field) analyses. ETT Environmental has also been contracted to perform effluent chronic toxicity tests. Influent Sampling # Is composite sampling flow proportional? Is sample collected above side streams? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is sampling performed according to the permit? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ EIN ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Comment: The subject permit requires BOD and TSS composite samples. The sampler tubing will need to be replaced within the near future. In addition, the ORC and staff must ensure the sampler strainer is collecting a well -mixed sample at the bar screen bypass discharge location. See "Summary" Section for additional comments. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? 0 ❑ ❑ ❑ Is sample collected below all treatment units? M ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? ❑ 0 ❑ ❑ Page# 4 Permit: NCO021181 Owner -Facility: Belmont WWTP Inspection Date: 02/28/2023 Inspection Type: Compliance Evaluation Effluent Sampling Yes No NA NE # Is proper temperature set for sample storage (kept at less than or equal to 6.0 0 ❑ ❑ ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type M ❑ ❑ ❑ representative)? Comment: The subject permit requires composite and grab effluent samples. The sampler tubing will need to be replaced within the near future. Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, ■ ❑ ❑ ❑ and sampling location)? Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The wastewater treatment facilitv appeared to be adequately treatinq wastewater during the inspection: however, an excessive solids inventory was being maintained as discussed further in the Aeration Basin, Secondary Clarifier and Disinfection -Gas Sections. See "Summary" Section for additional comments. Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? ■ ❑ ❑ ❑ Is the screen free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Is the unit in good condition? ❑ 0 ❑ ❑ Comment: The mechanical screen is currently being bypassed due to scheduled repairs that will be performed within the next two months. The manual bar (coarse) removes the larger debris but the smaller screenings pass through the treatment unit as observed in the secondary clarifiers. Grit Removal Type of grit removal a.Manual b.Mechanical Yes No NA NE Page# 5 Permit: NCO021181 Inspection Date: 02/28/2023 Grit Removal Owner -Facility: Belmont WWTP Inspection Type: Compliance Evaluation Yes No NA NE Is the grit free of excessive organic matter? ❑ 0 ❑ ❑ Is the grit free of excessive odor? ■ ❑ ❑ ❑ # Is disposal of grit in compliance? 0 ❑ ❑ ❑ Comment: The grit system is also being bypassed for scheduled repairs that will be performed within the next two months. The debris that has accumulated in the grit chamber will need to be removed and properly disposed prior to the repairs (chain replacement). Chemical Feed Is containment adequate? Is storage adequate? Are backup pumps available? Is the site free of excessive leaking? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: Sodium hydroxide is added into the influent prior to enterinq the aeration basin to maintain appropriate alkalinity/pH levels. The sodium hydroxide storage tank is double -walled and no leakages were observed. Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Surface Is the basin free of dead spots? ❑ ❑ ❑ ■ Are surface aerators and mixers operational? ■ ❑ ❑ ❑ Are the diffusers operational? ❑ ❑ 0 ❑ Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? ❑ 0 ❑ ❑ Is the DO level acceptable? 0 ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) 0 ❑ ❑ ❑ Comment: The facility is equipped with two aeration basins; however, one of the aeration basins has been taken out of service for many years. Seven of the eight aerators are operational and two aerator were operating during the inspection. The 30-minute settleability tests have been consistently high (980 ml/L) and the ORC and staff are challenged to run all needed aerators at one time due to the high solids inventory. The foam appeared a darker brown due to higher solids inventory and longer solids retention time. Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Page# 6 Permit: NCO021181 Inspection Date: 02/28/2023 Secondary Clarifier Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Owner -Facility: Belmont WWTP Inspection Type: Compliance Evaluation Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Yes No NA NE ❑ ■ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ Comment: The sludge blanket levels in both secondary clarifiers were not acceptable with the on -site measurements being 9.5 ft. in both clarifiers. The current sludge blanket levels pose a significant potential of being washed out during high flow events and the high solids inventory being maintained in the treatment processes contributes to these high levels. The unlevel weirs were not excessive and no short-circuiting was observed. Pumps-RAS-WAS Yes No NA NE Are pumps in place? 0 ❑ ❑ ❑ Are pumps operational? 0 ❑ ❑ ❑ Are there adequate spare parts and supplies on site? ❑ ❑ ❑ Comment: Disinfection -Gas Yes No NA NE Are cylinders secured adequately? 0 ❑ ❑ ❑ Are cylinders protected from direct sunlight? 0 ❑ ❑ ❑ Is there adequate reserve supply of disinfectant? 0 ❑ ❑ ❑ Is the level of chlorine residual acceptable? 0 ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? ❑ 0 ❑ ❑ Is there chlorine residual prior to de -chlorination? 0 ❑ ❑ ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. ❑ ❑ 0 ❑ 7782-50-5)? If yes, then is there a Risk Management Plan on site? ❑ ❑ 0 ❑ If yes, then what is the EPA twelve digit ID Number? (1000- If yes, then when was the RMP last updated? Page# 7 Permit: NCO021181 Inspection Date: 02/28/2023 Owner -Facility: Belmont WWTP Inspection Type: Compliance Evaluation Disinfection -Gas Yes No NA NE Comment: The level of solids (5.5 ft.) measured in the chlorine contact chamber was excessive during the on -site measurements. Approximately 1.5 ft. of clear water was observed on top of the level of solids. The solids must be removed/properly disposed and should be maintained at 1 ft. or less. The current level of solids measured in the chlorine contact chamber poses a significant potential of being washed out during high flow events and/or being re -suspended in the effluent due to denitrification (floating sludge clumps). De -chlorination Yes No NA NE Type of system ? Gas Is the feed ratio proportional to chlorine amount (1 to 1)? 0 ❑ ❑ ❑ Is storage appropriate for cylinders? 0 ❑ ❑ ❑ # Is de -chlorination substance stored away from chlorine containers? 0 ❑ ❑ ❑ Comment: Are the tablets the proper size and type? ❑ ❑ ❑ Are tablet de -chlorinators operational? ❑ ❑ ❑ Number of tubes in use? Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: The flow meter is calibrated quarterly and was last calibrated on 12/9/2022 Experienced Water Solutions, Inc. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ❑ ❑ 0 ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑ ■ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: The effluent appeared slightly turbid with trace suspended solids and no foam. The effluent is discharge through a submerged outfall in the receiving waterbody. Aerobic Digester Is the capacity adequate? Yes No NA NE ■ ❑ ❑ ❑ Page# 8 Permit: NCO021181 Owner -Facility: Belmont WWTP Inspection Date: 02/28/2023 Inspection Type: Compliance Evaluation Aerobic Digester Yes No NA NE Is the mixing adequate? 0 ❑ ❑ ❑ Is the site free of excessive foaming in the tank? 0 ❑ ❑ ❑ # Is the odor acceptable? 0 ❑ ❑ ❑ # Is tankage available for properly waste sludge? 0 ❑ ❑ ❑ Comment: The facility is equipped with two aerobic digesters and a sludge holding tank. Bio-solids are land applied by Southern Soil Builders under the authority of Permit No. WQ0003281. The level in the sludge holding tank is being lowered to allow for the removal of the tree/vegetation mats. Standby Power Yes No NA NE Is automatically activated standby power available? 0 ❑ ❑ ❑ Is the generator tested by interrupting primary power source? 0 ❑ ❑ ❑ Is the generator tested under load? ■ ❑ ❑ ❑ Was generator tested & operational during the inspection? ❑ ❑ ❑ Do the generator(s) have adequate capacity to operate the entire wastewater site? ❑ 0 ❑ ❑ Is there an emergency agreement with a fuel vendor for extended run on back-up ■ ❑ ❑ ❑ power? Is the generator fuel level monitored? ■ ❑ ❑ ❑ Comment: The backup generator does not power the blowers (aerobic digesters) and three aerators in the aeration basin. The generator is tested weekly (automatically) under load. The City also participates in Duke Power's load management program. City personnel services the generator annually. Page# 9