Loading...
HomeMy WebLinkAboutWQ0031396_Monitoring - 07-2022_20220718GW-59A COMPLIANCE REPORT FORM Permit # W00031396 (Submit one each monitoring period with GIV-59forms.) — ---- ---- ­­J-F Enter date monitoring results were due. (61 Will this monitoring report (GW-59 and GW-59A) YES NO be submitted after the established due date? X 2 Was any required information missing on the GW-59 report forms? YES NO IF the answer to question I or 2 is "YES, list in the space provided below the well identification number(s) and explain the problems encountered in obtaining the required information. X 3 Are any of the monitor wells in need of repair or maintenance (damaged casing, unlocked or missing cap, missing YES NO identification plate, area overgrown, etc.)? If the answer is "Yes ", contact the Regional ice for guidance X 4 Are any monitored constituents equal to or above the established standards? YES NO lfthe "answer'to question 4 is "NO", skip to section 8. If the answer to question 4 Is "YES" list the affected wells individualty with constituent(s) and concentration(s) exceeding standards in the space provided below: pH standard is 6.5-8.5. MW-1 field pH was 6.09. MW-2 field pH was 5.84. These results X reflect background concentrations because the WWTP is not yet active. 5 For theconstituentsIdentified In question 4 above, have standards been exceeded previously for the YES NO same constituent(s) In the same well(s) In the last two years? If the answer to question 5 is 'NO", skip to section 8. If the answer to question 5 is "YES", list in the space provided below, each well with constituent(s) exceeding standards, concentration(s) reported, and sample collection date for each occurrence (for the last two years). X 6 Are themonitoringweltslistedin section 5 located at or beyond the review boundary? YES NO If the answer is "YES", a groundwater quality problem may be occurring. CONTACT THE REGIONAL OFFICE IMMEDIATELY FOR GUIDANCE. If the answer Is "NO", monitoring wells may be improperly located; contact the Regional Office. 7 Is the permittee Implementing previously approved actions required by the Division involving this YES NO groundwater quality problem? If the answer to question 7 is "YES", describe those actions in the space provided below. If the answer to question 7 is "NO" contact the Regional Office within 90 days; an evaluation may b required to determine the impact the waste disposal system is having at the review and coin pliangg 'j boundaries surrounding this facility. Failure to do so may subject the permiffee to a Notice of Violation. fines. andlor penalties. 8 The person completing this portion (GW-59A) of the monitoring report should fth b616W and submit th form with GW-59 forms for required wells to the address provided at the top of the current GW-59 form. I hereby acknowledge that the above information was evaluated and the information submitted In this report (Compliance Report GW-59A) is true and complete to the best of my knowledge. Jonathan Gerst, MS, PG, Principal Hydrogeologist 7/18/2022 Peak Hydrogeologic, PI-I-C Signature of Permittee (or Authorized Agent) Date GW-59A 12/912003 SUBMIT FORM ON YELLOW PAPER ONLY • • DEPARTMENT OF ENVIRONMENTAL QUALITY - DIV. OF WATER RESOURCES GROUNDWATER QUALITY MONITORING: INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM • • 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7/31/2024 Facility Name: Santeetlah Lakeside WWTP (Lake Point Properties on Santeetlah, LLC) Non -Discharge UIC Permit Name (if different): Reclaimed Water Generation & Dedicated Utilization System Permit NPDES Other WQ0031396 Facility Address: 14 Marina Drive TYPE OF PERMITTED OPERATION BEING MONITORED ❑ Lagoon ❑ Remediation: Infiltration Gallery ake Santeetlah NC 28771 County Graham (City) (SL=te) {Lir) El Spray Field El Remediation: Contact Person: Jose Rosado for Jack Minski Telephone#: 305.772.5111 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name:MW-1 No. of wells to be sampled: 2 ❑ Water Source Heat Pump K Other: Reclaimed Water Drip Fiel (from Permit) SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW-1 Date sample collected:7/12/2022 FIELD ANALYSES: WAS Well Depth: 93 ft. Well Diameter:2 in. pH 00400: 6.09 units Temp. 000lo:20.6 °C DRY at 76.98 53 Depth to Water Level s2sas: ft. below measuring point Screened Interval: ft. to 93 ft. Spec. Cond. 000sa: µ Mhos time of sampling, Measuring Point is -0.32 ft. above land surface Relative M.P. Elevation: pending ft. Odor 00085: none check Volume of water pumped/bailed before sampling: 12 gallons Appearance clear here: ❑ Samples for metals were collected unfiltered: ❑■ YES El NO and field acidified: NYES El NO LABORATORY INFORMATION Date sample analyzed:7/12/2022 - 7/18/2022 Laboratory Name: Pace Analytical Certification No. 37712 / 40 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead o1o51 ug/L Coliform: MF Fecal 316161.0 /100mL Nitrate (NO3) as N 006200.20 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 006650.090 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 703oo 53.0 mg/L Al -Aluminum 01105 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 ND mg/L Ca - Calcium 00916 mg/L Chloride 00940 1.2 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia 00610 ND mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH, as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Jonathan Gerst, MS, PG, Principal Hydrogeologist for Peak Hydrogeologic Permittee (or Authorized Agent) Name and Title - Please print or type _'Z d; 7/18/2022 Signature of Permittee (or Authorized Agent) (Date) GW-59 Rev.06-07-2018 SUBMIT FORM ON YELLOW PAPER ONLY • • DEPARTMENT OF ENVIRONMENTAL QUALITY - DIV. OF WATER RESOURCES GROUNDWATER QUALITY MONITORING: INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM • • 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7/31/2024 Facility Name: Santeetlah Lakeside WWTP (Lake Point Properties on Santeetlah, LLC) Non -Discharge UIC NPDES Other W00031396 Permit Name (if different): Reclaimed Water Generation & Dedicated Utilization System Permit Facility Address: 14 Marina Drive TYPE OF PERMITTED OPERATION BEING MONITORED El Lagoon ❑Remediation: Infiltration Gallery ake Santeetlah NC 28771 Graham County (City) (Stzte; (Zip'J ❑ Spray Field ❑Remediation: Contact Person: Jose Rosado for Jack Minski Telephone#: 305.772.5111 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name:MW-2 No. of wells to be sampled: 2 ❑ Water Source Heat Pump X Other: Reclaimed Water Drip Fie[ (from Permit) SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW-2 Date sample collected: 7/12/2022 FIELD ANALYSES: WAS Well Depth: 25 ft. Well Diameter: 2 in. pH 00400:5.84 units Temp. 000lo: 18.3 °C DRY at Depth to Water Level 82546:14.18 ft. below measuring point Screened Interval: 5 ft. to 25 ft. Spec. Cond. 00094: µMhos time of sampling, Measuring Point is -0.45 ft. above land surface Relative M.P. Elevation: P•°'°9$0�ey ft. Odor 00085: none check Volume of water pumped/bailed before sampling: 8 gallons Appearance clear here:❑ Samples for metals were collected unfiltered: X YES ❑ NO and field acidified: ■❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed:7/12/2022 - 7/18/2022 Laboratory Name: Pace Analytical Certification No. 37712 / 40 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead o1o51 ug/L Coliform: MF Fecal 31616 ND /100mL Nitrate (NO3) as N 0062o ND mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 ND mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 7030035.0 mg/L Al - Aluminum olim mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 ND mg/L Ca - Calcium 00916 mg/L Chloride 0094014.6 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia 00610 ND mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH3 as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni- Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Jonathan Gerst, MS, PG, Principal Hydrogeologist for Peak Hydrogeologic Permittee (or Authorized Agent) Name and Title - Please print or type �` -- 7/18/2022 Signature of Permittee (or Authorized Agent) (Date) GW-59 Rev.06-07-2018