HomeMy WebLinkAbout20221558 Ver 2_More Info Received_20230302S
H
E
R
R
I
F
P
L
A
C
E
W
E
S
T
2
3
'
-
0
"
10'-0"
1
3
'
-
0
"
1
0
'
-
0
"
N 53
°
3
0
'
1
4
"
E
101.
4
1
EIP
2
6
'
-
2
"
N24° 26'06"W
5.00
NIP
RIPARI
A
N
ZONE
1
30'-0"
RIPARI
A
N
ZONE
2
20'-0"
50'-0"
CREEK
5
0
'
R
I
P
A
R
I
A
N
B
U
F
F
E
R
3
0
'
R
I
P
A
R
I
A
N
B
U
F
F
E
R
NIP
NIP
NIP
CP
N 50
°
1
8
'
3
6
"
E
34.2
0
S81°26'10"E
35.30
N22°33'15"E
9.79
S77°81'66"
W
96.36
NIP
385.56' TO A POINT WHERE
SHERRIF PL. W. BEGINS TO TURN
INTO CONTINENTAL WAY
CONC. DRIVE
1 STORY SIDING
5608 SHERRIF
PLACE W
S
1
2
°
4
1
'
0
4
"
E
9
1
.
7
7
P
O
R
C
H
S
3
2
°
4
6
'
3
0
"
E
4
3
.
0
5
SITE PLAN
SCALE: 1/16" =1'0"S1
1
N
NEW PORCH
5608 SHERRIF PL W RALEIGH NC 27610-5471
SITE PLAN GENERAL NOTES
INDEX OF DRAWINGS
UTILITY NOTES
SITE KEY MAP
LEYEND
S
M
T
X
HYD
IRON PIN, EXISTING
IRON PIN, SET
MARK IN CONCRETE
MAGNETIC NAIL SET
MATHEMATICAL POINT
FIRE HYDRANT
LIGHT POLE
SEWER CLEANOUT
SEWER MANHOLE
A/C UNIT
WATER METER
GAS METER
TELEPHONE PEDESTAL
CABLE TV PEDESTAL
ELECTRICAL BOX
TRANSFOMER
YARD INLET
BACK FLOW PREVENTER
FENCE LINE
MASONRY RETAINING WALL
SUBDIVISION CONTROL CORNER
S1 COVER
S2 PLANS & NOTES
S3 ELEVATIONS SECTIONS & DETAILS
BUILDING SUMMARY
1. ALL WORK SHALL COMPLY WITH CITY, STATE OF NORTH CAROLINA.
AND ALL OTHER MUNICIPAL CODES & APPLICABLE STANDARDS. IN CASE
OF CONFLICT BETWEEN REQUIREMENTS, THE MOST RESTRICTIVE SHALL
APPLY.
2.THE CONTRACTOR IS RESPONSIBLE TO ENSURE THE PROJECT BE IN
CONFORMANCE WITH CODES AND REGULATIONS OF ALL APPLICABLE
GOVERNING BUILDING AUTHORITIES, THE 2018 NORTH CAROLINA
BUILDING CODE, AND INTERNATIONAL BUILDING CODE WITH NORTH
CAROLINA AMENDMENTS, AND MANUFACTURERS RECOMMENDATIONS.
3. THE PURPOSE OF THIS DRAWINGS IS TO SHOW THE INTENT OF THE
DESIGN AND CONSTRUCTION PER THE OWNERS SPECIFICATIONS. WHILE
EVERY EFFORT HAS BEEN MADE IN THE PREPARATION OF THESE
DOCUMENTS TO AVOID MISTAKES, THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR, ANY CHANGES TO THESE DOCUMENTS AFTER
DE DATE ON THESE DRAWINGS WILL BE DONE AT THE OWNERS EXPENSE
AND RESPONSIBILITY, IN CASE OF DISCREPANCIES THE DESIGNER &
ENGINEER SHALL BE IMMEDIATELY CONTACTED.
4. THE CONTRACTOR IS RESPONSIBLE FOR SECURING ALL REQUIRED
APPROVALS AND PERMITS FROM THE APPROPRIATE AGENCY AND FOR
COORDINATION AND COSTS ASSOCIATED WITH CONSTRUCTION AND
INSPECTION
5.THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL
CONDITIONS, DIMENSIONS AND OTHER DETAILS PRIOR TO
CONSTRUCTION. THE CONTRACTOR SHALL ASSUME AL RESPONSIBILITY
THEREAFTER. THE CONTRACTOR IS RESPONSIBLE TO ENSURE THAT
PROVISIONS ARE MADE AND APPROVED METHODS USED FOR
CONSTRUCTION
6. THE CONTRACTOR SHALL ACCEPT RESPONSIBILITIES FOR ANY
UNSEEN CONFLICTS OR CONSTRUCTION COMPLEXITIES DISCOVERED
DURING CONSTRUCTION NOT DESCRIBED UN THE CONSTRUCTION
DOCUMENTS, NOTIFY THE ARCHITECT, AN COORDINATE NECESSARY
MEANS AND METHODS TO PROCEED.
1.CONTRACTOR SHALL COORDINATE AND BE RESPOSIBLE FOR ALL
UTILITIES, AS REQUIRED. (ELECTRIC MECHANICAL, PLUMBING, GAS) TO
CONSTRUCT THIS PROJECT
2.CONTRACTOR SHALL INVESTIGATE ANS ASSESS THE CONDITION
AND CAPABILITIES OF EXISTING UTILITY SERVICES FOR MEETING OR
EXCEEDING THE NEEDS OF THIS PROJECT
3.CONTRACTOR SHALL PROPOSE MOST ENERGY EFFICIENT SYSTEMS,
PROPOSE EXISTING SYSTEM UPGRADES AND MODIFICATIONS, AND
SERVICE LOCATIONS AND RUNS PRIOR TO CONSTRUCTION FOR REVIEW
BY DE OWNER (AND/OR OWNERS REPRESENTATIVES).
PIN: 1732568207
REID:0178680
CITY :RALEIGH
JURISDICTION: RALEIGH
TOWNSHIP: ST. MARY'S
LAND CLASS: RESIDENTIAL LESS THAN 10 ACRES
BUILDING DATA:
HEATED AREA: 1,114 SQFT
YEAR BUILT : 1996
USE: RESIDENTIAL SINGLE FAMILY
TOTAL STRUCTURES:1
TOTAL UNITS: 1
PROPOSED ADDITION:
EXISTING DECK: 130 SQFT
PROPOSED DECK: 100 SQFT
S1
COVER SHEET
SHEET
NO. DATE
PROJECT NO: 22-257
FILENAME: SHERRIF PORCH
CHECKED BY: HDS
DRAWN BY: K.I.
DATE: 03-01-2023
1011 S. HAMILTON ROAD
SUITE 222
CHAPEL HILL, NC 27517
LICENSE C-4889
REVISIONS
PLAN INFORMATION
CONTENT
THE DRAWINGS AND PLAN ENGINEERING ARE
THE PROPERTY OF HDS ENGINEERING ISSUED
EXCLUSIVELY FOR THIS PROJECT AND SHALL
NOT BE DUPLICATED OR USED FOR OTHER
PURPOSES, IN WHOLE OR PART, WITHOUT
WRITTEN PERMISSION OF HDS ENGINEERING.
HDS ENGINEERING ASSUMES NO LIABILITY FOR
DEVIATIONS FROM OR MODIFICATIONS MADE
TO THE PLANS BY OTHERS. HDS ENGINEERING
WILL NOT BE HELD RESPONSIBLE FOR
CONTRACTOR'S FAILURE TO CONFORM TO
CONSTRUCTION DOCUMENTS, FAILURE TO
NOTIFY ENGINEER OF KNOWN DISCREPANCIES,
OR CONSTRUCTION MEANS AND METHODS.
NE
W
P
O
R
C
H
56
0
8
S
H
E
R
R
I
F
P
L
W
RA
L
E
I
G
H
N
C
2
7
6
1
0
-
5
4
7
1
SEAL
23015
01/03
IMPACT OF PROPOSED ADDITIONS ON RIPARIAN
ZONE 2
PROPOSED DECK: 100 SF
PROPOSED PORCH (ABOVE EXISTING DECK) : 97 SF