HomeMy WebLinkAboutNC0086142_Renewal (Application)_20150302 .,
AQUA ..
March 2, 201 5
Wren Thedford
NC DENR / DWR/ NPDES Unit
1617 Mail Service Center
Raleigh, NC 27699-0167
Re: Application for Permit Renewal
Aqua North Carolina, Inc.
Oakley Park Subdivision Wells #1 & #2
NPDES No. NC0086142
Gaston County
Ms. Thedford:
Enclosed are three (3) copies of the completed application Short Form C- WTP.
This submittal includes the necessary attachments for your office to renew the
subject permit.
If you need any additional information or assistance, please feel free to
contact our Regional Compliance Manager, Michael A. Melton @ 704-489-9404
ext. 57238 or by e-mail at MAMelton@aquaamerica.com.
Since -ly,
Thomas . Roberts
President & COO
Enc
202 MacKenan Court,Cary, NC,27511 • 919.467.8712 • AquaAmerica.com
NPDES PERMIT APPLICATION - SHORT FORM C - WTP
For discharges associated with water treatment plants
Mail the complete application to:
N. C. Department of Environment and Natural Resources
Division of Water Quality / NPDES Unit
1617 Mail Service Center, Raleigh, NC 27699-1617
NPDES Permit Number NC0086142
If you are completing this form in computer use the TAB key or the up - down arrows to move from one
field to the next. To check the boxes, click your mouse on top of the box. Otherwise,please print or type.
1. Contact Information:
Owner Name Aqua North Carolina, Inc.
Facility Name Oakley Park Subdivision-Well #2
Mailing Address 202 Mackenan Ct
City Cary
State / Zip Code NC/27511
Telephone Number (919) 653-5770
Fax Number (919) 460-1788
e-mail Address TJRoberts@aquaamerica.com
2. Location of facility producing discharge:
Check here if same as above 0
Street Address or State Road NCSR 1236 at NCSR 1271- Well #2
City Gastonia
State / Zip Code NC/ 28056
County Gaston
3. Operator Information:
Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the
Operator in Responsible Charge or ORC)
Name Aqua North Carolina, Inc.
Mailing Address 4163 Sinclair Street
City Denver
State / Zip Code NC / 28037
Telephone Number (704)489-9404
Fax Number (704)489-9409
Page 1 of 3 Version 5/2012
NPDES PERMIT APPLICATION - SHORT FORM C - WTP
For discharges associated with water treatment plants
4. Ownership Status:
Federal D State ❑ Private ® Public 0
5. Type of treatment plant:
0 Conventional (Includes coagulation, flocculation, and sedimentation, usually followed by
filtration and disinfection)
❑ Ion Exchange (Sodium Cycle Cationic ion exchange)
® Green Sand Filter (No sodium recharge)
❑ Membrane Technology (RO, nanofiltration)
Check here if the treatment process also uses a water softener ❑
6. Description of source water(s) (i.e. groundwater, surface water)
Groundwater Well #1
7. Describe the treatment process(es) for the raw water:
Raw water is treated by greensand filters in series with a 0.001 MGD discharge of filter
backwash wastewater. Chemicals utilized during this process consist of:
• Potassium Permanganate
• Chlorine
8. Describe the wastewater and the treatment process(es) for wastewater generated by the
facility:
Wastewater discharge from said treatment works at the location specified on the attached
map into McGill Branch, classified C waters in Catawba River Basin.
9. Number of separate discharge points: 1
Outfall Identification number(s) 002
10. Frequency of discharge: Continuous 0 Intermittent Ei
If intermittent:
Days per week discharge occurs: 1 Duration: 38 minutes
11. Plant design potable flow rate 0.031 MGD
Backwash or reject flow 0.0012 MGD
12. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including
latitude and longitude):
McGill Branch in the Catwaba River Basin
Page 2 of 3 Version 5/2012
NPDES PERMIT APPLICATION - SHORT FORM C - WTP
For discharges associated with water treatment plants
13. Please list all water treatment additives, including cleaning chemicals or disinfection
treatments, that have the potential to be discharged.
Alum / aluminum sulfate Yes No
Iron sulfate / ferrous sulfate Yes No
Fluoride Yes No
Ammonia nitrogen / Chloramines Yes No
Zinc-orthophosphate or sweetwater CP1236 Yes No
List any other additives below:
Chlorine
Potassium Permanganate
Caustic Soda
14. Is this facility located on Indian country? (check one)
Yes ❑ No
15. Additional Information:
• Provide a schematic of flow through the facility, include flow volumes at all points in
the water treatment process. The plan should show the point[s] of addition for
chemicals and all discharges routed to an outfall [including stormwater].
• Solids Handling Plan
16. NEW Applicants
Information needed in addition to items 1-15:
• New applicants must contact a permit coordinator with the NCDENR Customer
Service Center.
Was the Customer Service Center contacted? ❑ Yes ❑ No
• Analyses of source water collected
• Engineering Alternative Analysis
• Discharges from Ion Exchange and Reverse Osmosis plants shall be evaluated using a
water quality model.
17. Applicant Certification
I certify that I am familiar with the information contained in the application and that to the
best of my knowledge and belief such information is true, complete, and accurate.
Thom_.: J. Roberts President & COO, Aqua North Carolina, Inc.
P ' e• n.. eofPe-.on i g Ti/
-
Signature of : •plicant Dat-
North Carolina General Statute 143-215.6(b)(2)provides that Any person who knowingly makes any false statement representation,or certification in any application,
record,report,plan,or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that
Article,or who falsifies,tampers with,or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21
or regulations of the Environmental Management Commission implementing that Article,shall be guilty of a misdemeanor punishable by a fine not to exceed$25,000,or by
imprisonment not to exceed six months,or by both. (18 U.S.C.Section 1001 provides a punishment by a fine of not more than$25,000 or imprisonment not more than 5
years,or both,for a similar offense.)
Page 3 of 3 Version 5/2012
Aqua North Carolina, Inc.
Oakley Park Subdivision Wells #1 , #2 WTP
Latitude: 350 12' 32" (001) State Grid: Gastonia, North
350 11' 50" (002) Perntltted Flow: N/A
J.ongihule: 81°16'02"(001) Stream Class: C
810 15' 40" (001) Drainage Basin: Catawba Rive 1lasia
RecelAmStre: m: Mc Gill Branch Sub•Rasin: 03-08-37
Facility
Location
not to scale
NPDES Permit No. NC00861.42
North
�
1 Y o rth Gaston County