Loading...
HomeMy WebLinkAboutNC0086169_Notes 1998_19980124I nA /I- /f ,1// i1 /' I 17) twat j, ---/ l / ? - - i ? o00 40 000 QCk ta� 1,1040 AGENDA • Introductions • Options for Diffuser for Outfall 003 — Jeff Moody w/Alley, Williams, Carmen & King, Inc. Consulting Engineers • Site Visit (Rocky River Discharge Point) • Scheduling Changes • Outfall 003 Discharges Hannan, Christy L From: Oplinger, Al J Sent: Tuesday, January 20, 1998 4:02 PM To: Hannan, Christy L Cc: Hannan, Michael D; Orazem, Gerald J; Myhalyk,William P;Whiteman, William J Subject: Estimated HVAC&Filter backwash blowdown I have estimated the HVAC, ECWS& Sand Filter backflushing flows to outfall 003 to be as follows for the following months. HVAC Tower ECWS Filter Total Total Gall Day Gal/Day Gal/Day Gal/Day Gal/Mo. Oct. 8640 2160 1404 12,204 366,000 Nov. 7200 1728 990 9,918 298,000 Dec. 5760 1440 805 8,005 240,000 Jan. 5760 1440 811 8,011 240,000 Feb. 5760 1440 826 8,026 240,000 Mar. 7200 1728 958 9,886 297,000 Apr. 10,080 2160 1411 13,651 410,000 Please advise if you need additional data. Al O. Page 1 o, m RIVLR FLOW _ T 3" SER 350 x 45' 31D RAID ELBOW TYDEFLEX VALVE r1 2 — # 5 REBARS @ 6" O.C. d c z_ LOCATED @ EACH DIFFUSER io a c d a a III a L I I I I d d v 2 1/2" FLANGED _ c RISER PIPE z 33� o o I I I 3000 PSI CONCRETE In d W 8 5 REBARS LONGITUDINAL I I c 2 - # 4 REBAR TIES @ 12" O.C. LAP 10" r 0 n Of d �z III o °4 DIFFUSER PIPE — 20" DIFFUSER DETAIL NOT TO SCALE 18" 0 w 2QOO' aM REINFORCED STF.. - NTEGRAL METAL 167E FOR STRENGTH AND MK RESISTANCE E E 2 /' . iTEM OTT I DESCRIPTION 1 I 1 DQfa( VALVE V S%Sf n MUFUNC 2 1 1 1 BAMLF TANG :NCASTD N RU®ER L E -- .(W [102►nl 4' ANSR 125f RWa RED VALVE COMPANY, INC. aumf: CARNEUE, PA. 15106-050 ORDER Rk: MAT. PREIIMMY NOT FOR APPIUM PfAFM s —M C-UER No: PRWRETARY NDT E Im a�R K W U W ■N MMIL onj � Q �B M mIE A lMa, Ot 00a� m m mi m Iim wa ROUR to Fm0m=-,C SER. 35D x 4S STD. RAD. f1BUW W4 pm W : EL F: VA DATE: Vvv aim. m- um. CAD XME; M xuc: RS PLar SCUL. NONE owt x* RVS- _ Corning Incorporated Telecommunications Products Division P.O.Box 1700 Concord, North Carolina 28026-1700 704-569-6000 January 13, 1998 CORNING Mr. Mark McIntire NC Dept. of Environment, Health & Natural Resources Division of Water Quality Archdale Building 512 North Salisbury Street Raleigh, North Carolina 27604 Dear Mr. McIntire: Per our telephone conversation on Friday, January 9, 1998, a meeting has been scheduled for Wednesday, January 21, 1998 at the Corning, Inc. construction site southern part of Cabarrus County. The meeting will be located in Building A, Conference Room 123 at 10:30 AM. Representatives from Corning, Inc. and the Water and Sewer Authority of Cabarrus County will be attending. Subjects of discussion will include the design of a diffuser for Outfall 003 at the Rocky River and scheduling changes for the start up of the Corning, Inc. Concord Plant. Weather permitting, we will visit the discharge point for Outfall 003 at the Rocky River. Please bring boots and other necessary gear for this site visit. Lunch will be provided at the Corning, Inc. site at 12:00. I have made arrangements for 3 NCDEHNR representatives. Please let me know if this is enough. I look forward to seeing you on the 21st. If you have any questions, please contact me at (704) 569-6268. Sincerely, CORNING INCORPORATED Christy L. Hannan Sr. Environmental Control Engineer