Loading...
HomeMy WebLinkAbout20220398 Ver 3_MCMS to DWR_20230301N/ SUBJECT x PROPERTY V J O VICINITY MAP O J (NOT TO SCALE) _ O U0 �U Z Cn W 0 O J L a 00 a U J W 00 MITCHELL C(:)UNTY SCH0()Ls U M 3-8 MIDDLE SCHOOL MITCHELL COUNTY, NORTH CAROLINA PREPARED FOR: MITCHELL COUNTY SCHOOLS 72 LEDGER SCHOOL ROAD BAKERSVILLE NC 28705 KIM HODSHON (828)766-3437 SHEET LIST TABLE SHEET NUMBER SHEET TITLE C000 COVER --- SURVEY C101 EXISTING CONDITIONS & DEMOLITION PLAN C201 SITE PLAN C301 ROUGH GRADING & EROSION CONTROL PLAN PHASE 1 C302 ROUGH GRADING & EROSION CONTROL PLAN PHASE 2 C401 STORM DRAINAGE PLAN C402 STORM PROFILES C403 STORM PROFILES C501 FINE GRADING PLAN C601 UTILITY PLAN & PROFILES C921 SITE DETAILS C931 ROUGH GRADING & EROSION CONTROL DETAILS C932 ROUGH GRADING & EROSION CONTROL DETAILS C941 STORM DRAINAGE DETAILS C942 STORM DRAINAGE DETAILS C961 UTILITY DETAILS C998 NCGO1 DEVELOPMENT DATA OWNER/DEVELOPER CIVIL ENGINEER: CONTACT: MITCHELL COUNTY SCHOOLS 72 LEDGER SCHOOL ROAD BAKERSVILLE NC 28705 KIM HODSHON (828)766-3437 CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NC 28801 MICHAEL CAIN, P.E. (828) 252-5388 CDC INSPECTIONS HOTLINE: 828-771-4755 OR INSPECTION@CDCGO. C'OM Know whch'010W. Cal before you dig. ►, m ti v z w u v w m U z Ln i �(.n o0!� Lnw Y Q m E O U w (nrj U Cain CL 0) oo4 V: � w QY N x aO 0 UNto E 0 rp � r �� N N +r- N 04 U 0OD .. to "0 i U 3 Z W C s4 v �h UarI� Cope Associatesi Inc and is not be reproduced without prior written authorization. This draw Is intended to be used only fbr project and site specifically identified All design infcrmatk are the copyright of Cope Associates Inc. @ 2020 REVISIONS NO. I DATE DESCRIPTION 0 11 /04/22 ISSUED FOR BID 1 12/09/22 ADDENDUM 3 2 12/14/22 AGENCY SUBMITTALS 3 2/28/23 AGENCY SUBMITTALS DATE: 1 DRAWN BY: P J; duo coo Q r —UoW W-t 0.LUz -0 DWG NO. JCP ARCHITECT: COPE ARCHITECTURE 2607 KINGSTON PIKE, SUITE 5 KNOXVILLE, TN 37919 CONTACT: JAKE MCREYNOLDS (865) 694-9000 C000 PROJECT NO. 12208 71,- , I, ROBERT K. BRADY, JR., CERTIFY THAT THIS PLAT WAS DRAWN UNDER MY SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION (DEED DESCRIPTION RECORDED IN DEED BOOK 608, PAGE 934); THAT THE BOUNDARIES NOT SURVEYED ARE CLEARLY INDICATED AS DRAWN FROM INFORMATION AS SHOWN ON THE FACE OF THIS PLAT; THAT THE RATIO OF PRECISION AS CALCULATED IS 1:10000+; THAT THIS MAP MEETS THE REQUIREMENTS OF THE STANDARDS OF LAND SURVEYING IN NORTH CAROLINA (21 NCAC 56.1600); AND THAT THIS PLAT WAS PREPARED IN ACCORDANCE WITH GS 47-30 AS AMENDED. THIS SURVEY IS OF AN EXISTING PARCEL OR PARCELS OF LAND OR ONE OR MORE EXISTING EASEMENTS AND DOES NOT CREATE A NEW STREET OR CHANGE AN EXISTING STREET. WITNESS MY ORIGINAL SIGNATURE, REGISTRATION NUMBER AND SEAL THIS 05/15/2020 __________ DATE 40-rl ------------l�---------- --- - ROBERT K. BRADY, JR., PLS-3959 I, Robert K. Brady, Jr., certify that this map was drawn under my supervision from an actual GPS (or GNSS) survey made under my supervison and the following information was used to perform the survey: Class of survey: Class B Horizontal Positional accuracy:0.003 Vertical Positional accuracy: 0.005 Type of GPS (or GNSS) field procedure: Real -Time Kinematic networks Date(s) of survey: Datum/Epoch: NAD 83 (201 1)(EPOCH2O10.000) Published/fixed control: VRS Geoid model: GEOID12B Combined factor: 0.99982471 Units: U.S. Foot Horizontal positions are referenced to NAD83(201 1) Vertical positions are referenced to NAVD88 05/15/2020.......... DATE ;;��111 /V 444_� _ ROBERT K. BRADY JR PLS-3959 LINE TABLE LINE BEARING LENGTH L1 S83°15'45"W 16.73' L2 S45°02'27"W 51.38' L3 N 11 °58'30"E 51.95' L4 S83°15'45"W 42.61' L5 S62°07'44"E 70.80' GENERAL NOTES: 1. Property subject to all easements, rights -of -way and restrictions of record 2. Lines not surveyed are shown as broken lines from information referenced on the face of this plat 3. The area shown hereon was computed using the coordinate computation method 4. Subject property is not located within a flood hazard area according to flood insurance rate map 370161, panel 0872, suffix J dated February 4th, 2009 5. Location of utilities, whether public or private, is based upon field location of visible appurtenances 6. All distances are horizonal ground measured in US Feet 7. This plat has been prepared without the benefit of a title report which may reveal additional conveyances, easements, rights -of -way or building restrictions. A North Carolina licensed attorney -at -law should be consulted regarding correct ownership, width, and location of easements and other title questions revealed by the title examination. 8. This map does not transfer to anyone other than the persons or business named in the title block and may not be used without written authorization from Blackrock Surveying and Land Design, PC. 9. Trees with a trunk diameter greater than 12 inches are located. 10. This property is subject to regulatory stream buffers are regulations accompanying delineated wetlands. Sparks pP e ver \\ 28� D.B. 498, Pg. 299 a Ma g netic Sig underwo al yM\ \ PIN \ 0872-00-71-5576�A\ � Greene Pitman �' .... I\ D.B. 345, Pg. 449 McKinney . l \�`� 28 \ s \ P PIN 0872-00-71-7482 D.B. 203 P 425 g \ \ �'. \ D.B. 473, Pg. 335 PIN 0872-00-71-4478 18' o �\ \A' PI PIN 0872-00-71-9584 1 /2» \ 1 2„ > S°\ 6' Bent IPF MA \ \ \ I \� ;o 2735.26' ,1 ' \ 1 \ q Stake on top \XA 2' C CH \ \ \ 1/2"\ �� \ � 1 \YO of ridge found 14' o \ I¢F \\ I A 12J'\ \ \ O �ON 04 „16 ,OA \ \ 1�g�2 �� • CS . �O� PP �pu A 1 1 \ \ o� / % I I I I I 1 \� \ UG `� \ sY Existing / N ° I I I I ` MARK e Inv. House I\ �3 2734.71' PP RB 0 V" A°�a� co21k0 gl 1 °E Sign p'sy Sign°\� L+ 1'• of 2n r FzI N S S� P5p \7 s BS � Rim 2739.33' M°<� \ \ e oundt / I I I \\\R °�� Inv. 2734.53' Oc nce Post \2II II I III I III1 III 1 I I11I 1II II � \ w M4o 40 P°/ „ 277° ° PO \Polansky Fe / I GH o 4 UT 1 / 12 MAR; KD.B. 139, Pg. 228 C F PO PIN 0872-00-61-7575 C =CH`2?718 p L� / \Bri 2:Buildicg0/ 16, 12Q �04CH POMA 0 k o 16 \ \\ \ \ / I I ^ I I 1 I I I I I 12MA' SG �k �\ a? o� \ CH \ \ \ _� / 12" 0. 1 , 14 12 I I I I I AKA 1 m� nv1 a " \ 8\' q �o \ � Mitchell Council on Aging, Inc.9.27259' P a\B1 PO D.B. 230, Pg. 690 2 12" 22 PIN 0872-00-81-1233 m \f\ra B \ ) I I N / { 4 \Zim 27 7.07' 16' \ \ / I I I I Inv. 273 97' 1 2-°\ \ �y\ \ I I I 2730 5 9n �. 20 14' S \ \ I` \ \ �\ / I / 11 PF' Plea 0 \ I 2 �\ 1„ \ \ \ O. \ I I I I I I 3° het A \\ G OA �\ \ \ \ �° z, / 1 4 \ I I e 1 ' h 2„ \ \ Ic�Q I \ \\ \ \ --�� � � / DA" jeo call \ \\ \ \/ \ \ \ / / / / / I r\ / �° ne I I N I I I I I o 01/ PP1 -2510 HINLSin / I Leaning // Fenco� es 38 I l I / l l l I I I I \ \ \ l/� \ d, \ RBS 6' n lines PI / I / I / I 1 \ I \ / / ( I 1 \ 16" NLS o � wN Railroad Spike in OOA / I 1 \ \ o/ / / / \ \ \ 9 \ < Pole Found _ / I I I I / � \� J� o El. 2734.90' 22 H„ FH a 12" 6 Rim 2731.78' 2800 ° CH \ \ \ \ \ \ \ \ \ \ \ J I I Inv. 2726.18' z o8„ �2„ \ \\ \ \ \ \ \ \ \ We \ \ _ OA Ao la„ � co A / / \ \ \ \ / \ \ mC' Cl) o 12 / / \ \ \ \ \ \ , / / \\\ \ j 1 1 tin °A \ \ \ \ \ 1 / / 1 m O Polansky N I '►� D.B. 139, Pg. 228 PIN 0872-00-61-7575 P 24 2 OA„ \ 1� M / / \ \ \ I \/,� 1 \ MA o 2J�° 1 I \ \ \ \ \ \ / 1 \ \ 6 o O OA 4 / /OA _i ° m / / / / / \ \ \ \ \ \ \ reo/ 272 \' \ 3 1 3 o \ \ ,e � ° \ \ UT OA / / 2�3° / / / / \ \ \ \ \ \ \ / / / / / / 1 / \ c MN MARK 4.5' Tall PoKe Fence CorWe / O \ \ \ \ \ N\ L11 L4 v S88°28' 5"W 140.00' Fence (in disrepai4� RBS�et 3' on lin� / / / / 14.943 Ae>r s Fence Come I-' \ \ \ \ \ RW NLS at 6"- s S/ / / / / MN N 2 n RBS 3' onmeuBarn � / / / / / hed 30 / tiara e OA 00 Natural Gas Valves CD/ / /� u \ rrounded by bollards Taylor / / / / / / i / B6„ \ o 1 D.B. 322, Pg. 606 N / / PIN 0872-00-70-2694 / / \ ) I l rn I S� o 09' / / %T nk -�aikng / / \ \ RW � 4o i.n / Sp'g°t / � I \ MN I a -`_ �Vektical Z� \ N 40 House - D 'veway Pipe ¢ M c cis �f 56" Pine/ / / / / / / MA 1 2738.66'FF MA I\ \ 3 LO Cb RB'et on line / / / / Porch o I / 1 I / Concrete \\ g Rim 2717.56' 5. North & / / / ^ I Foundation \ N Inv. 2714.16' Aeo 8.03' South MM / " I �\ \ Q 4/pert M Cv 275 / / /----2-140/ / �rvTA / / I N l / ^ I 1 _ CO / 1 1 -2750 / J / / / / M° / RW MN\ • II �° UT ° I Building .a / R-MN ` 4 / / / / 5.59' from 1 MARK I / / o N20,588.51' OA 36" � MA corner / � / / 18" / / Block RW MN PP RW E 1,077,390.14' Mar in of per D B. 99, Pg. �a 1 / -2730� Building PP referencing tote Highway Project 18576 MA / �N-820,565.76' MN / / 2140 n \ nv. (! �I \ ti Rim 2715.98' C 2 3 .72' 2730- Inv. U V 1 I nv. 2713.08' - -� 27-�N88°05'33"W 683.60' Ground (683.48' Grid) P \ \ \ \ \ ` 2714.38 7 Inv. PP �_ 271 WV e Asphalt �- \ 24„�2(272 CM 2Double Yellow Line = �: Asphalt \ PI 16' ��• wVLo PI 1 S\ " PO DARK \ 272p© s PP Geodetic Monument �OQ>, Asphalt L1 / n ° 4sPho/t "Ledger \ \ �q 1.0/ El. 2717.84' Inv. RW MN Asphalt / /Single W eth L ' OOub/e Yellow Line c \2j�6 RW 2730.69' \\ Inv. S MN Approximate Margin of R/W 272202' - ' � Rim 2715.32' \ Inv. 2711.21' South N.C. Highway 226 - -° UT _2 7 MARK As 1 Variable R/W per N.C. DOT Project 8.18576 1, - -2716_PIP _ As halt hovvnc'ns all op .Site �vr' Rd, N.C. Hwy. 226 Wia9 VICINITY MAP (N.T.S.) 0- Legend ------------ RBF Rebar Found IPF Iron Pipe Found RBS Rebar and Cap Set RW MN Right of Way Monument Found NLS Nail Set N.T.S. Not to Scale D.B. Deed Book Pg. Page P.B. Plat Book PIN Parcel Identification Number R/W Right -of -Way PP Power Pole S.R. Secondary Road FF Finished Floor El. Elevation N Northing E Easting Inv. Invert CMP Corrugated Metal Pipe RCP Reinforced Concrete Pipe UT MARK Underground Telecommunications Line Marker UG MARK Underground Gas Line Marker SG Sign MA Maple PI Pine PO Poplar OA oak LO Locust WN Walnut CH Cherry BI Birch HI Hickory Calculated Point Water Meter CO Clean -Out Plug Telecommunications Pedestal AWV Catch Basin Water Valve • Guy Wire E Electric Meter C Cable Box S O Street Sign Sanitary Sewer Manhole F=® Fire Hydrant Mailbox Tree (diameter &type) Boundary and Topographic Survey for the Property of Mitchell County Snow Creek Township, Mitchell County, North Carolina PIN : 0872-00-70-6960 Current Owner: Mitchell Address: 5085 South N.C. Hwy. 226 County Bakersville, NC 28705 Field Dates: 04/28/2020, Drafting Dates: 04/29/2020, D.B./Pg.: 608 / 934 05/01/2020, 05/04/2020, 05/11/2020, 05/12/2020, 05/07/2020, 05/13/2020 05/14/2020 Job Number: 20-050 Firm License No.: C-2921 Surveyed by: RB Drawn by: RKB PLS: Robert K. Brady, Jr. GRAPHIC SCALE 50 0 25 50 100 200 1"=50' Po Box 8302 BLACKROCK Asheville, North Carolina SURVEYING 28814 phone: 828-225-4341 8� LAND DESIGN, PC www.blackrocksurveying.com NOTES 1. SEE UTILITY DETAIL SHEETS FOR ALL GENERAL WATER & SEWER NOTES. CONTRACTOR RESPONSIBLE FOR INCLUSION OF DETAILS SHEETS WITH ALL UTILITY PLANS. 2. WATER METERS ARE TO BE PLACED MAXIMUM OF 5' OFF EDGE OF PAVEMENT/SIDEWALK. WHEN A UTILITY STRIP IS PRESENT, METERS SHALL BE INSTALLED WITHIN STRIP. WHEN SIDEWALK IS CONSTRUCTED AND NO STRIP IS AVAILABLE, SERVICE LINES CROSSING SIDEWALK SHALL BE CONSTRUCTED WITH PVC SLEEVE EXTENDING 6" ON EITHER SIDE OF SIDEWALK PER SPRUCE PINE STANDARDS AND SPECIFICATIONS. 3. CROSSINGS TO MAINTAIN REQUIRED VERTICAL SEPARATION. CONTRACTOR TO CONTACT ENGINEER ON ANY CROSSING THAT DOES NOT MEET THIS SEPARATION, OR SEPARATION IS CLOSER THAN 1'. REFER TO GENERAL NOTES ON SEWER DETAIL SHEET FOR SEPARATION REQUIREMENTS BETWEEN UTILITIES. 4. TO SCHEDULE THE REQUIRED INSPECTIONS ON ALL WORK, CALL THE CIVIL DESIGN CONCEPTS INSPECTIONS HOTLINE AT 828-771-4755, OR EMAIL AT INSPECTIONS@CDCGO.COM. FAILURE TO SCHEDULE INSPECTIONS MAY RESULT IN UNCOVERING OR REDOING WORK. 5. TYPICAL EASEMENTS FOR WATER/SEWER LINES LOCATED OUTSIDE ESTABLISHED UTILITY EASEMENTS OR ROAD RIGHT-OF-WAYS SHALL BE AS SHOWN. THE ENTIRE WATER/SEWER EASEMENT MUST BE CLEAR AND REMAINED CLEARED OF TREE PLANTINGS, EXISTING TREES, AND ANY PERMANENT STRUCTURES. 6. NO PORTION OF THIS PROJECT LIES WITHIN THE 100-YR FEMA FLOODPLAIN. EXISTING TREES TO BE REMOVED (TYP) (STUMPS TO REMAIN TO AVOID SLOPE DISTURBANCE AND IMPACTS TO OTHER NEARBY TREES) �\ \ \ 1 X"\ \ �„ b l \ \ \ \� �o �- �\ \ � / �� s PIN 0872-00-71-9584 1 /2„ \ \M A \ 2„�q \ \ \ \ \ � �\ .� \\�\ � \\ Z �QInv. Bent \ \ \ MA �\ \ \ \ \ \ �. 1 \ \ 9a IPF \ \ \ �„ 0 \ \ '•\ \ s 2735.26' EXISTING ROAD CULVERT \ 1 1 \ \ \ 1 I \\ ca\ TO REMAIN (TYP) Stake on top \ 22" C C -� \ \ 1 /2" \ �\ of ridge found \ \ bA 14' o \ \\ \I \\ \ IPF 12" \ � �01 � �- s OA I \ I ` I 1 1 \ \ �' I �. \ \ / i�O01 01 e P I I I I I I I \I \ \\ \��\ ° 6p�°53 \ O , // I I, I I I � o \ ,� \ U G I , Ste/ e 5 0' Existing // N I I I I I 1 \ \ O MARK s�o 9 '� / I I I I 1\ Q I \ ` n v. House I I I I I I I I I 1 s � �0 12734.71'�j �•' • /\ I I I 1 I\� \ \ \ \ PP I RBS �cg I I I I II I I I I 1 1 1 �)�\\ �2�1k� �I� �• cS � 1 \ . \ \ P '�� CO / 1�' I I \ \ \\ I \� �\ \ o I I I 1 1 \ ~ �O �.■ �� I I I I 1 I I } I 1 �\ / \ \ \ c `� Sign SG 2� I I I I I I I 1 \ ��, \' \\ i S EXISTING FENCE I I I I I� 1 I 1 ) \' \ \ i Rim 2739.33' /n TO BE REMOVED (TYP) e —Rour zat i� I I \ I j / N\\ �� Inv. 2734.53' / '� 01ic'e Post /' I I I I Iftft I � � / \ <• EXISTING STREAM SECTION TO BE PIPED (SEE SHEET C300) ° UT w\ „� MARK \ F�e 240 PROPERTY LINE (TYP) \�. / I I I I I II I I I Polansk 2??o 0 I 1„ O 0 J 0y ^\\o 1 o " UT \ D.B. 139, Pg. 228 / cH _II II II 1 1\ 1 1 \ IPF II I _ \ \ Q PI 12" sU ARK \ PIN 0872-00-61-7575 cH c ---- I I \ 1 I I 1 I PO \ 1 � I I I I 1 I I sue, \ - �- 2>>0\11 \ \ \ Brick O \ �q�\Z� --- __ I I I \ I 1 1 1 1 1 I I I I I I J 12" lu 12„ \\ Ge L \ Building CH / ` I 1 1 I I I I I `� \ MA PO rD0 \��S' \ \ 0� 2�6 \ SG (16" EXISTING TREES TO REMAIN (TYP) # 1 \ CH o 14\ \ 11 \ \ a0 EXISTING WETLANDS 12,XA P(TO REMAIN) (TYP) -Po- V. Council on Ac W \ \ \ 29.59' 7 �8„ � �' Q \ ° ������� ��II \ \ \ \�6 / , _ \ o� _ I I I I I I I I I 1 ( PQ s �o \D.B. \ 18 � � , Pg . 690 \,p D230 \ \ \ \ \ I \ I I II II II I I I I I PO \�s \<,. \ PIN 0872-00-81-12� \ 22" 22 \ \ MA \ \12"\ 40" \ \ I'� � \ �' I � J / �o .v �l �l •Z I \ \ : \ P- 1 4" R\Im 2737.07 Co \ PO Iny. 273\97' \ 1 1 `P0o\ \ \, \ %; \ \ 0" \ 24 CH \ \ \ \ \ \ / I I ' I l I I .� .� / P P 2 `�' `�' `�' OA OAS \ I J I I n 12 1 \ \ \ I 1 I 12 \ 3 4" \ \ 4 \ CH I �?' OA EXISTI\ 14" I' \\ \ (FROM NT POOFTBANK) REAM BUFFER / I �" CH \ •v .v .v .v .v .v .v 2 ) \ \ \ 00 100, 0 C, / 1 �� 1 I I 1 �%�� EXISTING CRANBERRY BRANCH \ / I �° 1 I 1 \ \ 24' / c�i / i \ EXISTING WETLANDS TO I \ STREAM INDEX: 5-16-14 OA FI / / I 1 rn I I I o I \ \ \ \ BE REMOVED (TYP) CLASSIFICATION: C;Tr N I 1 I I I o 6'0 \ r \ \ \ _ - N� � RIVER BASIN: FRENCH BROAD \2%JnO N / \ / PP / / l l l I l l l I I l / I \ \ l \ \ / \ / / _: -_- M 38 PI LS .v .v .v 16 \ \ DEVELOPMENT DATA OWNER/DEVELOPER: CONTACT: CIVIL ENGINEER: CONTACT: SURVEYOR: CONTACT: ARCHITECT: CONTACT: PROJECT DATA VICINITY MAP (NOT TO SCALE) MITCHELL COUNTY SCHOOLS 72 LEDGER SCHOOL ROAD BAKERSVILLE NC 28705 KIM HODSHON (828)766-3437 CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NC 28801 MICHAEL CAIN, P.E. (828) 252-5388 BLACKROCK SURVEYING & LAND DESIGN, PC PO BOX 8302 ASHEVILLE, NC 28814 ROBERT K. BRADY, JR (828) 225-4341 COPE ARCHITECTURE 2607 KINGSTON PIKE, SUITE 5 KNOXVILLE, TN 37919 JAKE MCREYNOLDS (865) 694-9000 PIN: 0872-70-6960 ADDRESS: 5085 S. NC HWY 226 BAKERSVILLE, NC DEED BOOK/PAGE: 608/934 SITE ACREAGE: 14.93 ACRES ZONING: SNOW CREEK TOWNSHIP SETBACKS: N/A DISTURBED AREA: 12.26 AC PARKING CALCULATIONS: HANDICAPPED SPACES: SPACES REQUIRED: 5 SPACES PROVIDED: 5 VAN SPACES REQUIRED: 1 SPACES PROVIDED: 5 VEHICULAR MINIMUM REQUIRED: N/A AMOUNT PROVIDED: 117 BUILDING DATA: BUILDING DESCRIPTION HEIGHT GFA PROPOSED MIDDLE SCHOOL XX, 70,580 SF IMPERVIOUS CALCULATIONS: IMPERVIOUS PERVIOUS PRE -DEVELOPMENT: 0.11 ACRES (1%) 14.82 ACRES (99%) POST -DEVELOPMENT: 3.54 ACRES (24%) 11.39 ACRES (76%) 0 X \1 .11 \ \ \ _O�Railroad Spike in O12" / I I I I I \ I' \ \ 1 \ \ ICD\ I Pole Found OA El. 2734.90' ca O 06, \ \ ` \ 41 41 � � `� �, \ \\ \ \ EXISTING OVERHEAD UTILITY TO BE I I I \ \ - - _ REROUTED AS NEEDED (TYP) I / I I 1 \ 1 \ \ \ \ I \ \ I / _ \ \ \ APPROPRIATE UTILITY COMPANY) E WITH H / / I I I l I I I \\ \\ \ I \ \ I I \ _ _ . •� .� .� \ Os 1 \ - 1 \ \ \ 1 / _0 S Rim 2731 .78' 9. 12/ / / / I 1 \I \ \\ \ \ \ \ \ \\ \\ \\ \\ \ \\ \\ \\ \\ \ \ \\ \\ 11 l �' _ _ _ _ .� .� .� .� .� \ \ Inv. 2726.18' z OA / �2 , // // I \ 1 1 \\ \\ \ \\ \\ \\ \\ \\ \\ \\ \ \ \\ \\ \\ \ o ono - rno \ \ \ \ \ \ \ \ \ IUD) \ \ \ I \ y n \ co ­24- HI I \ \ \ \ \ Ul lop PPOA 41 141, 1 I ° (D T III �. \\ 10A 24„ OA I PO/ / \ EXISTING OVERHEAD UTILITY TO BE a ♦ 20' < 1 I ' I I \ r. REMOVED (TYP) (CONTRACTOR SHALL COORDINATE WITH APPROPRIATE UTILITY \ I / �' /' / \ COMPANY) 18" `I (D / 0 / / \ cP OUT OA 11 RW \ MARK L1 MN 4.5 Tall Pyle Fence Corrp-er / / \ \ \ I LQ S$$° 28�25"W 140.00 ___Fence (in disrep'G ir) RBS s &t'3' on lines---" , / / / 14.943 Aerbs ♦ sa Fence Corn / / /. / / / / / \ \ \ RW 2„ NLS at 6 Oak / / MN `\ I VAN o \ RBS 3' on-l`iri-es Barn / � i /� /� / J - \ cv / r \ 1 ♦ e �n i Shed \ 3 , I ag EXISTING BUILDING PP \ �`� O TO BE DEMOLISHED (TYP) \ /�/ � _ � /2 �50/ � \ • ��\\\ \ ( ��� �' � W � n I \Natural Gas O EXISTING GARAGE TO REMAIN /2 " �•3 \ \ \ m \� syarrounded h ADJACENT PROPERTY LINE (TYP) cn BI Taylor r a1 I I I \ I ./ y ♦ I I ��\I o Io D.B. 3221 Pg. 606LU O I J , l �? I 0)CA C \ PIN 0872-00-70-2694 SGNp EXISTING CONCRETE TO or- /' _ - I 1 \\ NRW BE REMOVED (TYP) Tank A \ CY ;t_ ♦ Sptgotp r - I �\ \\ '\ \ MN o Vertical II- �' House a_ `Drivew I 0Pipe \ \ [I 1CY)0 � oCn \ ♦ — 56" Pine e,.t �' / / /♦ MAO 2738.66TF 16l6w" \� it h 1 o I II / / / MA 0 \� � RBS son line Porch _ - / ' / COner"� a 1�2' North Foundat n \\•. I - - - EXISTING TREES O I \ / &/ 10 TO BE REMOVED (TYP) " ^ / \\\\ CDC INSPECTIONS HOTLINE. South / i - - - 18 cv / 828-771-4755 OR INSPECTION@CDCGO.COM 27 / / / /' / / 120 MA EXISTING SIDEWALK / J ^ 50— J / / / 2740 MA TO BE REMOVED (TYP) N -2750 / 'JI �(\ - /- MA / /�••�'1�� RW MI` , \/ \ R W M N - - �" - - - - - - - / 18r EXISTING GRAVEL DRIVE TO BE / / / / / �.5 ' from / \ REMOVED (TYP) EXISTING STORM LINE TO REMAIN aIN 20,588.01 \ I OA 36 /' MA _ _ / / /> / Horner (TYP) / / E71,077,390.14' I I t PO M - - -' 1- - 180 / Block / � P argin_of �/�fV-per D.B. 99, P 5 0� / / - N - - - referencing State Highway Proje t-8. 8 76 i MA EXI REMAIN CONNECTION 273 / / / // Building / - F / N-820,565. 6; Know what's below. / ?�4p In - - - - - y _� - - - - - - /� / E 1,078,073. 12/�33.72 \�\ - - - - - - \ - - _ _ - _ - - —2730 _ Ir N�38 / / / - - - ,I CaII before you dig. NORTH �05'33"W 683.60' Groun 68 .48' Grid \ - — — � �; "' EXISTING CONDITIONS & I Asphalt \ _ 27 2714.38 11 CMS ' 27 3 o I \ Double Yellow Line \ \ \ Asphalt v 4" PI " 20"f - _ �1 ��/ '1 / - So th N.C. 14i hway 226 PI I , \ 16- - oT _ DEMOLITION PLAN N PO \ 2726i GRAPHIC SCALE .1:11 \\ariable R/ per N.C./DOT Project 8 1857 ASMARK o Asphalt / / o `L 0 // _ phalt \ so o 15 so so izo / / A _ / Single Whit. :_ ' /DOuble YAIi_ ( IN FEET ) 1 inch = 30 ft. EcC, EcD, BdA, Ud, SaB, EdE, EcC, & ScC B, C, &D V J 0 0 z OQ J z 0 0 �0 J 0 O I _ w 0 U z o �_ o Wz o J 0 0 z �U 0 X LLJ J — W 0O Z UM G Ln 0 r` (� N N N Q }z Q J �o c� Q _U U� z� O �z Dw O (A J Ln > COCn oOf LnW Y Q m E 0 U N 7 oQ o2 � U �r�II CO Q � U 00 41-0 41-0 s LO V � � .3 L N � N a ° _ '7u 0 N O 0 N Q � O � C UNhe LI E 0 U U) L0�0 L0 V 0 � N O 06 00 M N � U 00 N H U a � 00 N •o 3�z LU W X C o m° '> d W Ua4 w w U m z This drawing is the property of Cope Associates, Inc and is not to be reproduced without prior written authorization. This drawing is intended to be used only for the project and site specifically identified. All design information are the copyright of Cope Associates Inc. © 2020 REVISIONS NO. DATE DESCRIPTION 0 11 /04/22 ISSUED FOR BID 1 12/09/22 ADDENDUM 3 DATE: 12/2/2022 DRAWN BY: JCP 00 -¢°to -vau� < Za J - %y°off=�Q` oN°°°° DWG NO. C101 PROJECT NO. 12208 FULL SHEET SIZE: 36"X48' NOTES 1. SEE UTILITY DETAIL SHEETS FOR ALL GENERAL WATER & SEWER NOTES. CONTRACTOR RESPONSIBLE FOR INCLUSION OF DETAILS SHEETS WITH ALL UTILITY PLANS. 2. WATER METERS ARE TO BE PLACED MAXIMUM OF 5' OFF EDGE OF PAVEMENT/SIDEWALK. WHEN A UTILITY STRIP IS PRESENT, METERS SHALL BE INSTALLED WITHIN STRIP. WHEN SIDEWALK IS CONSTRUCTED AND NO STRIP IS AVAILABLE, SERVICE LINES CROSSING SIDEWALK SHALL BE CONSTRUCTED WITH PVC SLEEVE EXTENDING 6" ON EITHER SIDE OF SIDEWALK PER SPRUCE PINE STANDARDS AND SPECIFICATIONS. 3. CROSSINGS TO MAINTAIN REQUIRED VERTICAL SEPARATION. CONTRACTOR TO CONTACT ENGINEER ON ANY CROSSING THAT DOES NOT MEET THIS SEPARATION, OR SEPARATION IS CLOSER THAN 1'. REFER TO GENERAL NOTES ON SEWER DETAIL SHEET FOR SEPARATION REQUIREMENTS BETWEEN UTILITIES. 4. TO SCHEDULE THE REQUIRED INSPECTIONS ON ALL WORK, CALL THE CIVIL DESIGN CONCEPTS INSPECTIONS HOTLINE AT 828-771-4755, OR EMAIL AT INSPECTIONS@CDCGO.COM. FAILURE TO SCHEDULE INSPECTIONS MAY RESULT IN UNCOVERING OR REDOING WORK. 5. TYPICAL EASEMENTS FOR WATER/SEWER LINES LOCATED OUTSIDE ESTABLISHED UTILITY EASEMENTS OR ROAD RIGHT-OF-WAYS SHALL BE AS SHOWN. THE ENTIRE WATER/SEWER EASEMENT MUST BE CLEAR AND REMAINED CLEARED OF TREE PLANTINGS, EXISTING TREES, AND ANY PERMANENT STRUCTURES. 6. NO PORTION OF THIS PROJECT LIES WITHIN THE 100-YR FEMA FLOODPLAIN. SITE LEGEND rmL)rr_m I T LIINt - - RIGHT OF WAY LINE - - SAWCUT LINE - - - - - - - PROPOSED SIGHT TRIANGLE PROPOSED HEAVY DUTY PAVEMENT PROPOSED LIGHT DUTY PAVEMENT PROPOSED CONCRETE SIDEWALK PROPOSED LANDSCAPE AREA X-1 �0 0 .I PROPOSED I� 1 - 8'x18' ADA PARKING SPACES (TYP) I 1 - 8' WIDE VAN -ACCESSIBLE LOADING AISLE (SEE DETAIL D2.11) I 1 - HANDICAP PARKING SIGNS (SEE DETAIL D2.12) NOTES: i -HC SYMBOLS TO NOT BE STRIPED PROPOSED STANDARD/HI-VISIBILITY CROSSWALK (TYP) (PER MUTCD STANDARDS) PROPOSED 18" CURB & GUTTER (TYP) (SEE DETAIL D2.06) PROPOSED EDGE OF PAVEMENT (TYP) i / PROPOSED HEAVY DUTY ASPHALT / PAVEMENT (TYP) (SEE DETAIL D2.15) //@D 'Oe6 looe ZZ PROPOSED SCHOOL BUILDING (SEE ARCH. PLANS) PROPOSED CONCRETE SIDEWALK (TYP) (SEE DETAIL D2.08) PROPOSED STOP SIGN (SEE DETAIL D2.01) PROPOSED CONCRETE FLUME (SEE DETAIL D2.16) PROPOSED ACCESSIBLE RAMPS (TYP) (SEE DETAIL D2.14) PROPOSED CANOPY (SEE ARCH. PLANS) PROPOSED BUS LOADING AREA R51.4' R5.0' R80.0' lIe7l4 / / tJ vNY ,x,/_/00i PROPOSED ACCESSIBLE RAMP (TYP) (SEE DETAIL D2.14) R84.0' 1 24.0' � R40.5' a a R9.5' R40.5 R9.5' d• d R119.1' / e v/ da / d ° d d d R10.0'� V d� 24 0' � ss o \ mcP \ UT MA R76.0' PROPOSED CURB END TREATMENT / (TYP) (SEE DETAIL D2.10) / PROPOSED ASPHALT MILL & OVERLAY 25' ON 50 BOTH SIDES TO MATCH EXISTING PAVEMENT' (SEE NCDOT DETAIL 654.01) co 5 Signar SGS S PROPOSED CONNECTION TO EXISTING ROAD Rim 2739.33' (CONTRACTOR TO PROVIDE SMOOTH TRANSITION Inv. 2734.53' AND NOTIFY ENGINEER AFTER FORMING BUT s / PRIOR TO POURING CURBS AND PAVEMENT) s / \ PROPOSED STOP BAR (TYP) \ (PER MUTCD STANDARDS) WV O PROPOSED STOP SIGN �1ARK (SEE DETAIL D2.01) \ R100.0' PROPOSED 6' CONCRETE SIDEWALK (TYP) (SEE DETAIL D2.08) G \ Z PROPOSED 6' TURN DOWN CONCRETE SIDEWALK R42.0' (TYP) (SEE DETAIL D2.09) _ 1 ss / \ R41.0' \ R20.0' R19.0co Rim 2737.07' Inv. 2732.97' \4/CO .1/ \11 I \ S /. .1/ R41.0' I I CA \ R 41 0' \ PROPOSED RETAINING WALL \ MAX HEIGHT 13' (TYP) (DESIGNED BY OTHERS) 14, 141, CD STOP AND NO RIGHT TURN SIGN `V `4' `4' `4' 11' \ / R � R41.0' . R41.0' �� q/ q/ \11 \1/ \1/ \1/ PP 'IV .� 1 � � \ // / \4' \0 "V I PROPOSED 42" PEDESTRIAN �� BARRIER FENCE 'W OD 41 41 \\ 41 41 41 141, .� .� � FH \ S Rim 2731.78' R166 0' \ Inv. 2726.18' VICINITY MAP (NOT TO SCALE) DEVELOPMENT DATA OWNER/DEVELOPER: MITCHELL COUNTY SCHOOLS 72 LEDGER SCHOOL ROAD BAKERSVILLE NC 28705 CONTACT: KIM HODSHON (828)766-3437 CIVIL ENGINEER: CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NC 28801 CONTACT: MICHAEL CAIN, P.E. (828) 252-5388 SURVEYOR: BLACKROCK SURVEYING & LAND DESIGN, PC PO BOX 8302 CONTACT: ASHEVILLE, NC 28814 ROBERT K. BRADY, JR (828) 225-4341 ARCHITECT: COPE ARCHITECTURE 2607 KINGSTON PIKE, SUITE 5 KNOXVILLE, TN 37919 CONTACT: JAKE MCREYNOLDS (865) 694-9000 PROJECT DATA PIN: 0872-70-6960 ADDRESS: 5085 S. NC HWY 226 BAKERSVILLE, NC DEED BOOK/PAGE: 608/934 SITE ACREAGE: 14.93 ACRES ZONING: SNOW CREEK TOWNSHIP SETBACKS: N/A DISTURBED AREA: 12.26 AC PARKING CALCULATIONS: HANDICAPPED SPACES: SPACES REQUIRED: 5 SPACES PROVIDED: 5 VAN SPACES REQUIRED: 1 SPACES PROVIDED: 5 VEHICULAR MINIMUM REQUIRED: N/A AMOUNT PROVIDED: 117 BUILDING DATA: BUILDING DESCRIPTION HEIGHT GFA PROPOSED MIDDLE SCHOOL XX' 70,580 SF IMPERVIOUS CALCULATIONS: IMPERVIOUS PERVIOUS PRE -DEVELOPMENT: 0.11 ACRES (1%) 14.82 ACRES (99%) POST -DEVELOPMENT: 3.54 ACRES (24%) 11.39 ACRES (76%) SOIL TYPE EcC, EcD, BdA, Ud, SaB, EdE, EcC, & ScC SOIL GROUP: B, C, &D PROPOSED 4 - 8'x18' ADA PARKING SPACES (TYP) 2 - 8' WIDE VAN -ACCESSIBLE LOADING AISLE (SEE DETAIL D2.11) 4 - HANDICAP PARKING SIGNS (SEE DETAIL D2.12) NOTES: -HC SYMBOLS TO NOT BE STRIPED R144.0' CD I PROPOSED CANOPY N OS i (SEE ARCH. PLANS) \ O Cn W W W W 2�0' PROPOSED 8'x21' PARALLEL / CID I IUq O O PARKING SPACE (TYP) / PROPOSED HEAVY DUTY • d \\ V) < PP , \ \ I ,� �• O CRETE (SEE DETAIL D2.03) R4.0' R4.0' \ )POSED DUMPSTER PAD PROPOSED TRANSFORMER LOCATION \ \ �' .i i I �• W D FENCE (SEE DETAILS R6.0' PROPOSED 9'x18' 04 & D2.05) 240 (TYP) STANDARD PARKING SPACE _ I O \ R 10.0' \ 0s CCa lull, \ 24.0' I I R4.0' R30.0' R52.0' N I PROPOSED STOP SIGN AND DIRECTIONAL SIGN \ I (HIGHWAY 226 EAST TURN LEFT) PROPOSED BAR GATE R10.0' 1 \ I EXISTING CRANBERRY BRANCH STREAM > ° R5. \ i OUT MARK PROPOSED HARD COURT & PLAY SPACE 4 4 .aR 0, 14.0' / STOP AND NO RIGHT TURN SIGN i (SEE ARCH. PLANS) \ / R9.0/ ts� II ° \ R117.0' \ / as ° / R61.0' R9.0 j/ R97.0' PROPOSED "DO NOT ENTER" SIGN S 4 4 4 V) 'k. 00 I PROPOSED STOP SIGN 4 (SEE DETAIL D2.01) O PROPOSED BAR GATE 30' STREAM BUFFER (TYP) /� s R220.0' I I R60.0' PROPOSED LIGHT DUTY ASPHALT / I 'I SG \ I I PROPOSED STOP SIGN AND DIRECTIONAL SIGN // / PAVEMENT (TYP) (SEE DETAIL D2.02) (HIGHWAY 226 EAST TURN RIGHT) I I (HIGHWAY 226 WEST TURN LEFT) R76.0' R254.0'Sb PROPOSED CURB END TREATMENT � / \ \. PROPOSED STOP SIGN AND NO / / (TYP) (SEE DETAIL D2.10) LEFT TURN SIGN / I \ � � / \ / / R20.0' I 1 \ \\ CDC INSPECTIONS HOTLINE: \ PROPOSED TURN LANE \ \ /� 828-771-47550RINSPECTI0N@CDCG0.00M O �\ / PROPOSED STOP SIGN/BAR 34.0 \ � \ \ � tP \ / (PER MUTCD STANDARDS) / \ I (SEE DETAIL D2.01) 12.0' i17i 11.0' \� %/ z z / / Know what's below. Call before you g. fdiNORTH \\ i St 1211 0= - = SITE PLAN hi1 • • a ]h av 22690.4' U MARK © N GRAPHIC SCALE Variable R/W per N.C. DOT Project 8.18576 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. j /_15.5 R2.5' d � / a ) / R231.0' a� ° I I a � I e d R236.0' 11.9, R171.0' I 9 � RA- \ ° \ I 72 i < nd Il \ R236.0' a \ 120 V J J O OJ O Up Ln o U r` �o CO N N NQ }z Q J O o W CE Q = o z Q [I-z J Q U�_ z� O LLJ U p 0w 0 J �J ,n > COOf J o� Lnw W M N. Q m UM C� G !_ 0 U N 7 O U ocD .°� O U rn aa) 0- LO 0 00 V W s V � 0, L u•�M N � N }a c ° _ '7u O as .I-. O Ilm N Qr o�C UNhe !_ 0 U N -a LO L0L0_0 V 0 � N O 0600M N 0 U 00 a� 0 a o 00 N I--�--i a 3�z r � � W X LU om°O•> Q N U a 4 4 bu a z a m V=f O LL Ho E§ z a r w p LL J,a a w3 0 Q d U) c� c a0O a UaU 3 w w m z This drawing is the property of Cope Associates, Inc and is not to be reproduced without prior written authorization. This drawing is intended to be used only for the project and site specifically identified. All design information are the copyright of Cope Associates Inc. © 2020 REVISIONS NO. DATE DESCRIPTION 0 11 /04/22 ISSUED FOR BID 1 12/09/22 ADDENDUM 3 DATE: 12/2/2022 DRAWN BY: JCP -vaLo tn� W- %y°off =1// O/V a a a ° 4� DWG NO. C201 PROJECT NO. 12208 FULL SHEET SIZE: 36"X48" NOTES 1. SEE UTILITY DETAIL SHEETS FOR ALL GENERAL WATER & SEWER NOTES. CONTRACTOR RESPONSIBLE FOR INCLUSION OF DETAILS SHEETS WITH ALL UTILITY PLANS. 2. WATER METERS ARE TO BE PLACED MAXIMUM OF 5' OFF EDGE OF PAVEMENT/SIDEWALK. WHEN A UTILITY STRIP IS PRESENT, METERS SHALL BE INSTALLED WITHIN STRIP. WHEN SIDEWALK IS CONSTRUCTED AND NO STRIP IS AVAILABLE, SERVICE LINES CROSSING SIDEWALK SHALL BE CONSTRUCTED WITH PVC SLEEVE EXTENDING 6" ON EITHER SIDE OF SIDEWALK PER SPRUCE PINE STANDARDS AND SPECIFICATIONS. 3. CROSSINGS TO MAINTAIN REQUIRED VERTICAL SEPARATION. CONTRACTOR TO CONTACT ENGINEER ON ANY CROSSING THAT DOES NOT MEET THIS SEPARATION, OR SEPARATION IS CLOSER THAN 1'. REFER TO GENERAL NOTES ON SEWER DETAIL SHEET FOR SEPARATION REQUIREMENTS BETWEEN UTILITIES. 4. TO SCHEDULE THE REQUIRED INSPECTIONS ON ALL WORK, CALL THE CIVIL DESIGN CONCEPTS INSPECTIONS HOTLINE AT 828-771-4755, OR EMAIL AT INSPECTIONS@CDCGO.COM. FAILURE TO SCHEDULE INSPECTIONS MAY RESULT IN UNCOVERING OR REDOING WORK. 5. TYPICAL EASEMENTS FOR WATER/SEWER LINES LOCATED OUTSIDE ESTABLISHED UTILITY EASEMENTS OR ROAD RIGHT-OF-WAYS SHALL BE AS SHOWN. THE ENTIRE WATER/SEWER EASEMENT MUST BE CLEAR AND REMAINED CLEARED OF TREE PLANTINGS, EXISTING TREES, AND ANY PERMANENT STRUCTURES. 6. NO PORTION OF THIS PROJECT LIES WITHIN THE 100-YR FEMA FLOODPLAIN. ROUGH GRADING & EROSION CONTROL LEGEND LIMITS OF DISTURBANCE SILT FENCE SKIMMER & CONTROL STRUCTURE TEMPORARY PIPE EXISTING CONTOURS PROPOSED CONTOURS TEMPORARY DIVERSION DITCH PERMANENT DIVERSION DITCH STONE INLET PROTECTION SLOPE PROTECTION SF 00 f To f TD PD PD PD i STRUCTURE TABLE (INVERTS BASED ON 2D LENGTH TO INSIDE EDGES) STRUCTURE STATION STRUCTURE DETAILS DEPTH DESCRIPTION RIM 2740.9 C1 11+31 INV. IN 2735.2 (C2-Cl) 6.0't OPEN THROAT INV. OUT 2735.1 (Cl-CO) RIM 2746.3 C2 12+55 INV. IN 2738.3 (C3-C2) 8.3'f OPEN THROAT INV. OUT 2738.2 (C2-Cl) RIM 2749.5 C3 14+62 INV. OUT 2744.6 (C3-C2) 5.4'f OPEN THROAT RIM 2739.6 Z1 10+44 INV. IN 2730.8 (Z2-Z1) 8,8'f CURB INLET INV. OUT 2730.8 (Z1-ZO) INLET/OUTLET TABLE (INVERTS BASED ON 2D LENGTH TO INSIDE EDGES) STRUCTURE STATION STRUCTURE DETAILS DESCRIPTION CO 10+36 INV. IN 2734.1 (Cl-CO) FES ZO 10+69 INV. IN 2730.5 (Z1-Z0) INV. IN 2730.5 (EX-ZO) HEADWALL Z2 10+15 INV. OUT 2731.1 (Z2-Z1) HEADWALL PIPE TABLE (SLOPES BASED ON 2D LENGTH TO INSIDE EDGES) PIPE NAME SIZE LENGTH SLOPE MATERIAL C1-CO 30" 92' 1.1% HDPE C2-Cl 30" 121' 2.5% HDPE C3-C2 30" 203' 3.1% HDPE EX-ZO 48" 35' 2.8% RCP Z1-Z0 54" 22' 1.2% RCP Z2-Z1 54" 25' 1.2% RCP 1 o rR ROPOSED 24" HDPE TEMPORARY PIPE 'B'EMOVEPIPE WHEN POSSIBLE .0% MIN. SLOPE) (SEE DETAIL D4.01) \\ \ /'� \ \\ \��\ \ \`�• \ p PROPOSED PUMP AROUND FOR \ \\ \ \ \ \ I STREAM DIVERSION INSTALLATION (SEE DETAIL D3.07) PROPOSED TEMPORARY DIVERSION DITCH "B" BOTTOM WIDTH: SIDE SLOPE: 2:1 DEPTH: SLOPE: 2% MIN. \ \ , \ \ \ \ \ \ \ \� 1 \ I \ \ \ 0 I CHANNEL LINER: S75BN \ \ \ \\ \ I (SEE DETAIL D3.05, D3.10) A EXISTING 48" RCP STORM PIPE PROPOSED 2' CONTOURS (TYP) PROPOSED 50'x25'x12" CONSTRUCTION ENTRANCE (TYP) (SEE NCDOT DETAIL 1607.1) _J\_ \ / / i (CONSTRUCTION ENTRANCE TO BE MAINTAINED / / I PROPOSED S_ I I I I II I I /i AND ADDITIONAL STONE ADDED ON REGULAR BASIS AS NEEDED)'' INSTALLED DURING ROUGH GRADING I I 1 � \ \ \ TO BE INSTALLED FOLLOWING STREAM PIPE \ / � / / I I Ialeft I I I I 1 I 1 I \ S \ \ \ \ \ \ / INSTALLATION � PROPOSED STORM PIPE (TYP) �' / / I I I I *aft LATITUDE: 35.9669 (SEE TABLE AND DETAIL D4.01) \ � \ \ \ - - / / / / � i I I I II I � II I �I � i / \ \ \ / LONGITUDE:-82.1164 i PROPOSED STORM STRUCTURE (TYP) / PROPOSED CONNECTION TO EXISTING \ � � / ' / I 1, I I \ � � I \ I t 48" RCP STORM PIPE (SEE TABLE & DETAIL D4.12) C1 - - - F \ \ \ / / / SF I \I s Z2 \ EX. INVERT ELEVATION: 2731.5' EXISTING 2' CONTOURS (TYP) � � � - - - _ �' ' / C2 \ - ' TD . ■ � � � " l . I / I 1 \ \ ` `\ \ PROPOSED STORM HEADWALL (TYP) • • 1 1 I I Z1 ` (SEE TABLE & DETAIL D4.03) O ZO ♦ I ( \ \ PROPOSED DEWATERING BAG PLACED ON AGGREGATE \ \ \ \ _ - ♦ I I 1 \ 1 1 I I •� I I \ \ \ \ OR STRAW UNDERLAYMENT (SEE DETAIL D3.08) 4!# I \ PROPOSED PERMANENT RIP RAP APRON CO 41, I I I I I I I I I - \ \ LENGTH: 16' \ _ \ � ♦ / I I I I I I CO I � �'� ".�_� •. \ \ WIDTH AT START: 7.5' PROPERTY LINE (TYP) \ \ \ (� v ♦ / / / I I I I I I I I I I I / ° / /� \ \ WIDTH AT END: 18.5' DEPTH: 1.5" \ \ \ / ♦ / / I I I I I I I I I/ / I J\�/ ( \ \ STONE CLASS: B � �� ♦♦ ' - / / I I I I I I I I I to I I l \ \ \ \ \ (SEE DETAIL D3.09) PROPOSED TEMPORARY INLET PROTECTION ' �♦ / I I I I I I I \p \\ (TYP) (SEE DETAIL D3.03) ♦ � ' / c3, � �♦ \\ \ ��\ ���\\ //* m � I.•I � � \ \ \ \ \ / I I I I ' v3 \ \ �I I I I \ \ \ \ \ \ \ I �j \ \ /b 1 \ 1 I I PROPOSED TEMPORARY BERM \ \ \ \ \ \ \ \ \ \ -`� I O 0/ 4 I I I TO DIRECT ON FLOW TO C3 \ \ \ \ \ \ / \ \ \ _ - - _ / / / / , / I / � I \ I I I I I %*4e ' \ / /,0 (n �• �I ` I cn� �• �• �• � w \ \ \ \ 4,// wIJ, PROPOSED TEMPORARY DIVERSION DITCH "A2" BOTTOM WIDTH: 2' � / / /o N �►' \ .v .v .v + \ \ SIDE SLOPE: 2:1 / / / / / / \ \ \ \ DEPTH: 1' \ \ SLOPE: 2% MIN. // // .v CHANNEL LINER: S75BN / / / CD (SEE DETAIL D3.05, D3.10) / / / / / / o / v .v .v .� I. .v •v •v \ \ / / l l l I I I � \ � / / / / •v .v .v .v I \v v \ � \ \ \ PROPOSED LAYDOWN AREA DEVELOPMENT DATA OWNER/DEVELOPER: CONTACT: CIVIL ENGINEER: CONTACT: SURVEYOR: CONTACT: ARCHITECT: CONTACT: PROJECT DATA VICINITY MAP (NOT TO SCALE) MITCHELL COUNTY SCHOOLS 72 LEDGER SCHOOL ROAD BAKERSVILLE NC 28705 KIM HODSHON (828)766-3437 CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NC 28801 MICHAEL CAIN, P.E. (828) 252-5388 BLACKROCK SURVEYING & LAND DESIGN, PC PO BOX 8302 ASHEVILLE, NC 28814 ROBERT K. BRADY, JR (828) 225-4341 COPE ARCHITECTURE 2607 KINGSTON PIKE, SUITE 5 KNOXVILLE, TN 37919 JAKE MCREYNOLDS (865) 694-9000 PIN: 0872-70-6960 ADDRESS: 5085 S. NC HWY 226 BAKERSVILLE, NC DEED BOOK/PAGE: 608/934 SITE ACREAGE: 14.93 ACRES ZONING: SNOW CREEK TOWNSHIP SETBACKS: N/A DISTURBED AREA: 12.26 AC PARKING CALCULATIONS: HANDICAPPED SPACES: SPACES REQUIRED: 5 SPACES PROVIDED: 5 VAN SPACES REQUIRED: 1 SPACES PROVIDED: 5 VEHICULAR MINIMUM REQUIRED: N/A AMOUNT PROVIDED: 117 BUILDING DATA: BUILDING DESCRIPTION HEIGHT GFA PROPOSED MIDDLE SCHOOL XX' 70,580 SF IMPERVIOUS CALCULATIONS: IMPERVIOUS PERVIOUS PRE -DEVELOPMENT: 0.11 ACRES (1%) 14.82 ACRES (99%) POST -DEVELOPMENT: 3.54 ACRES (24%) 11.39 ACRES (76%) SOIL TYPE EcC, EcD, BdA, Ud, SaB, EdE, EcC, & ScC SOIL GROUP: B, C, &D +- - l / / / / I I I I I I I I I I I I I 1 I \ 1 1 1 I \ \ / \ \ / - _ _ - _ , / / / / / / / �c / •�• •�• •►• •�• �, \ \ . � �Z •�• \ \\, \ \ I � / 1 / / / / I I I I I I I I I I I I \ 1 , \ I \ \ \ I \ � / / / / / / / / �' % \ '•\' �' \ \ \ �/ PROPOSED CONCENTRATED FLOW OUTLET ----IIJ- ' 1 / /' / ; I I I , I I I I I I I I 1 , 1 \ \ \ I \ \ \l I \\ \_ -- �' /' / / ' o � / •v v v v c � ' �• v \ \ j 0 j � / // / � I I � I I I � II I I 11 11 1 \ \ \ \ \ I \ , I \ ---- � / / / I -� 1 I 1 \\ \ I I I I I 1 \ \ \ \ I \ \ I / / / / I ,v I .v .v .v .v v \ \ • w U_ \ s I `n � .i• .i• I \ •.\•• '' `'' \ \\ \ \ / + "Op vAl min I `\ \ \ 1 )k --- V o EXISTING CRANBERRY BRANCH V \ \ \ \ CLASSIFICATION: C; Tr / / / / \ \ \ \ \ \ \ RIVER BASIN: FRENCH BROAD � PROPOSED TEMPORARY RIP RAP APRON A2 \ \ \ \ A LENGTH: 13.0' \ \ \ 1 WIDTH AT START: 6.0' WIDTH AT END: 15.0' \ \ \ \ \ \ \ \ \ \ DEPTH: 1.5" � / TD (s�E DETAIL D3.09) NE CLASS: B I `\ `\ `\ `\ `\ `\ `\ \\ `\ �� \ • .�\ \ TD TD w TD TD �`TD �� TD / / / / / / I \ \ \ \ \ \ \ \ \ ��Jl \ \ O (TYP) (SEE DETAIL D3.06) CJ1 � I \ PROPOSED 50'x25'x12" CONSTRUCTION ENTRANCE I \ O (TYP) (SEE NCDOT DETAIL 1607.1) (CONSTRUCTION ENTRANCE TO BE MAINTAINED �. I H AND ADDITIONAL STONE ADDED ON REGULAR V CC BASIS AS NEEDED) rl O TO BE INSTALLED FOLLOWING STREAM PIPE INSTALLATION 1\ r ( LATITUDE: 35.9661 LONGITUDE:-82.1159 O ' EXISTING 30' STREAM BUFFER I (FROM TOP OF BANK) I 1 PROPOSED DOUBLE ROW SILT FENCE (TYP) (SEE DETAIL D3.02) I \ PROPOSED TEMPORARY SKIMMER BASIN A (SEE SHEET C932) PROPOSED TEMPORARY DIVERSION DITCH "Al" BOTTOM WIDTH: 1' SIDE SLOPE: 2:1 DEPTH: 1' - SLOPE: 2% MIN. - / I �' c / /' / / \ \ \ \ / \\� • I: \ CHANNEL LINER: C125BN / / / - / PROPOSED SILT SOCK (SEE DETAIL D3.17) (SEE DETAIL D3.05, D3.10) / / , / / i PROPOSED 18" HDPE TEMPORARY PIPE 'A1' / `/ / / / / / \ \ -� \ \ \ \ \ / t i PROPOSED TEMPORARY RIP RAP APRON 'SKIMMER A' REMOVE PIPE WHEN POSSIBLE I i \ \ \ I \ LENGTH: 24.0' (1.0% MIN. SLOPE) (SEE DETAIL D4.01) \WIDTH AT WIDTH AT END: 26.0, / I<3i / / \ \ I Gay / �• I DEPTH: 1.5" OB (SEE DETAIL D3.09) ADJACENT PROPERTY LINE TYP PROPOSED 50'x25'x12" CONSTRUCTION ENTRANCE I `IL QU\1 / �� i' / / PROPOSED TEMPORARY RIP RAP APRON 'A1' / 1�� ` I x I I N \ �I� �•' s� I (TYP) (SEE NCDOT DETAIL 1607.01) (CONSTRUCTION �' / LENGTH: 8.0' ENTRANCE TO BE MAINTAINED AND ADDITIONAL WIDTH AT START: 3.0' STONE ADDED ON REGULAR BASIS AS NEEDED) / i �/ / WIDTH AT END: 9.0' LATITUDE: 35.9647 / / DEPTH: 1.5" LONGITUDE:-82.1177 (SEDETAIL D3.09) VIP OE NE CLASS: B / / / J - - \`-l� / l \ \ II // I I /.y / 1 • \ CDC INSPECTIONS HOTLINE: 8S 828-771-4755 OR INSPECTION@CDCGO. COM IJ \ l + Know what's below. -`u- TD -® TD STD ��7p�TD TD-� TD 1 TD TD TD T \ / / C1II before you dig. NORTH ft _ - - - - , , f , , ' / / / / / / ROUGH GRADING & EROSION I ��� r - - - - // / // / /' `� CONTROL PLAN PHASE I 7N'7-\ SF - - SF - SF SF - _ SF SF SF - _ _ _ _ _ _ , �' // / �� GRAPHIC SCALE C _ / 120 f1 w ' w U' v, Q J z 0 CL J 0 o J 0 o 0 z ' ` v 0 0 z 0 U) Ln U w U) z Wo J 0 � 0 = Q 0 U Of J C) J W Oo UM G Ln 0 r` �o C0 N N N Q } z Q J �o c� Q _U U� z� 0 �z Dw 0 (A J Ln > COCn C:) Of Lnw Y Q m E 0 U N O U o cD .2 0) U rn � � Q LO 0 00 V V � 0, N � N a ° _ '7u 0 N o �� Q.- E 0 •moo C UNhe LI E 0 U N L0�0 L 0 V 0 04 04 N 00M 00 N 0 U °?cod H a C'4 00 N 0 •o 3�z W X C O m �> oON U a 4 w `w U m Z This drawing is the property of Cope Associates, Inc and is not to be reproduced without prior written authorization. This drawing is intended to be used only for the project and site specifically identified. All design information are the copyright of Cope Associates Inc. © 2020 REVISIONS NO. DATE DESCRIPTION 0 11 /04/22 ISSUED FOR BID 1 12/09/22 ADDENDUM 3 DATE: 12/2/2022 DRAWN BY: JCP Q a o m J00Ld WQ�- -vain tn� W00 - DWG NO. C301 PROJECT NO. 12208 F SE zSF - F - -SF S NMI_ IIIIIIIIIIIIIIm aft V \ \\ C n a -i fb 1NT 0 Tom; "b 1 _X Ta t T 'i'i \\ / _ l ( IN FEET ) 1 inch = 30 ft. FULL SHEET SIZE: 36"X48' NOTES 1. SEE UTILITY DETAIL SHEETS FOR ALL GENERAL WATER & SEWER NOTES. CONTRACTOR RESPONSIBLE FOR INCLUSION OF DETAILS SHEETS WITH ALL UTILITY PLANS. 2. WATER METERS ARE TO BE PLACED MAXIMUM OF 5' OFF EDGE OF PAVEMENT/SIDEWALK. WHEN A UTILITY STRIP IS PRESENT, METERS SHALL BE INSTALLED WITHIN STRIP. WHEN SIDEWALK IS CONSTRUCTED AND NO STRIP IS AVAILABLE, SERVICE LINES CROSSING SIDEWALK SHALL BE CONSTRUCTED WITH PVC SLEEVE EXTENDING 6" ON EITHER SIDE OF SIDEWALK PER SPRUCE PINE STANDARDS AND SPECIFICATIONS. 3. CROSSINGS TO MAINTAIN REQUIRED VERTICAL SEPARATION. CONTRACTOR TO CONTACT ENGINEER ON ANY CROSSING THAT DOES NOT MEET THIS SEPARATION, OR SEPARATION IS CLOSER THAN 1'. REFER TO GENERAL NOTES ON SEWER DETAIL SHEET FOR SEPARATION REQUIREMENTS BETWEEN UTILITIES. 4. TO SCHEDULE THE REQUIRED INSPECTIONS ON ALL WORK, CALL THE CIVIL DESIGN CONCEPTS INSPECTIONS HOTLINE AT 828-771-4755, OR EMAIL AT INSPECTIONS@CDCGO.COM. FAILURE TO SCHEDULE INSPECTIONS MAY RESULT IN UNCOVERING OR REDOING WORK. 5. TYPICAL EASEMENTS FOR WATER/SEWER LINES LOCATED OUTSIDE ESTABLISHED UTILITY EASEMENTS OR ROAD RIGHT-OF-WAYS SHALL BE AS SHOWN. THE ENTIRE WATER/SEWER EASEMENT MUST BE CLEAR AND REMAINED CLEARED OF TREE PLANTINGS, EXISTING TREES, AND ANY PERMANENT STRUCTURES. 6. NO PORTION OF THIS PROJECT LIES WITHIN THE 100-YR FEMA FLOODPLAIN. ROUGH GRADING & EROSION CONTROL LEGEND LIMITS OF DISTURBANCE SILT FENCE SKIMMER & CONTROL STRUCTURE TEMPORARY PIPE EXISTING CONTOURS PROPOSED CONTOURS TEMPORARY DIVERSION DITCH PERMANENT DIVERSION DITCH STONE INLET PROTECTION SLOPE PROTECTION SF 00 f TD f TD PD PD PD EXISTING 2' CONTOURS (TYP) HATCHED AREA; ALL SLOPES GREATER THAN 3:1 SHALL BE HYDROSEEDED WITHIN 7 DAYS OF ESTABLISHED I / FINISH GRADE FOR STABILIZATION. PERMANENT VEGETATION SEED TO CONFORM WITH SEEDING I I I I I \ REQUIREMENTS SHOWN ON DETAIL SHEET. PROPOSED STORM SYSTEM (TYP) I I `� ref /�r•� � I � PROPOSED STORM BYPASS PIPE 'C' INSTALLED DURING ROUGH GRADING PROPOSED PERMANENT DIVERSION DITCH "A" BOTTOM WIDTH: 2'---� SIDE SLOPE: 3.1 i Ores \ \ DEPTH: 1.5' \2 — ' �� D D I V SLOPE: 2% MIN. I I 1 \ \\ \ \\ \ CHANNEL LINER: C350 �\ / !/�,\ ■I \\ \ \ \ \ \ (SEE DETAIL D3.04, D3.10) PD -41 \ \ \ \ \ \ o \ \ \40t,/ ♦♦ / I / / �� %\\ ,4"\ \ \ \�\\\\ , ♦ , o \\\ \ \�`\ \ \ I ♦ j I `�� a I / / I \�S \\ \\\ \\ \ \\\ \\ -Q0 I / p0 o �,,♦\ / / I I I II I `` I '":I I { ' /�/� / '�v, / PROPOSED TEMPORARY DIVERSION DITCH "C" BOTTOM WIDTH: 0' PROPERTY Nm SIDE SLOPE: 2:1 IlIl 41 �►\ \\ \ W i' \ \ DEPTH: 1 I \ �C5 � \ \ \ \\ \ \ \ \ \ \ \ \\ \� \ -_1 / / I Ii`� y \ \ CHANNEL LINER: S75BN I I \ \ \ \ \ \ \ \\ \ \ \J\� \ \4f/ I j, J r �' J' �' �' �' J' \ \ (SEE DETAIL D3.05, D3.10) I \ \ \ \ 1-1 I l 00 I I 1 VICINITY MAP (NOT TO SCALE) DEVELOPMENT DATA OWNER/DEVELOPER: MITCHELL COUNTY SCHOOLS 72 LEDGER SCHOOL ROAD BAKERSVILLE NC 28705 CONTACT: KIM HODSHON (828)766-3437 CIVIL ENGINEER: CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NC 28801 CONTACT: MICHAEL CAIN, P.E. (828) 252-5388 SURVEYOR: BLACKROCK SURVEYING & LAND DESIGN, PC PO BOX 8302 CONTACT: ASHEVILLE, NC 28814 ROBERT K. BRADY, JR (828) 225-4341 ARCHITECT: COPE ARCHITECTURE 2607 KINGSTON PIKE, SUITE 5 KNOXVILLE, TN 37919 CONTACT: JAKE MCREYNOLDS (865) 694-9000 PROJECT DATA PIN: 0872-70-6960 ADDRESS: 5085 S. NC HWY 226 BAKERSVILLE, NC DEED BOOK/PAGE: 608/934 SITE ACREAGE: 14.93 ACRES ZONING: SNOW CREEK TOWNSHIP SETBACKS: N/A DISTURBED AREA: 12.26 AC PARKING CALCULATIONS: HANDICAPPED SPACES: SPACES REQUIRED: 5 SPACES PROVIDED: 5 VAN SPACES REQUIRED: 1 SPACES PROVIDED: 5 VEHICULAR MINIMUM REQUIRED: N/A AMOUNT PROVIDED: 117 BUILDING DATA: BUILDING DESCRIPTION HEIGHT GFA PROPOSED MIDDLE SCHOOL XX' 70,580 SF IMPERVIOUS CALCULATIONS: IMPERVIOUS PERVIOUS PRE -DEVELOPMENT: 0.11 ACRES (1%) 14.82 ACRES (99%) POST -DEVELOPMENT: 3.54 ACRES (24%) 11.39 ACRES (76%) . m * `�' `�' `�' / \ \ \ AZ SOIL TYPE EcC, EcD, BdA, Ud, SaB, EdE, EcC, & ScC \\ SOIL GROUP: B, C, &D UJ J //1 I I ODDL_E / \YITCHEL�/A \ \ % / / I •� 1 \ \ �\ \\ ALL 2:1 SLOPES AND GREATER TO BE STABILIZED `�' `�' `�' `�' `�' n \ WITH ROLLED EROSION CONTROL PRODUCT RICAN GREEN 758N OR APPROVED\ EQUAL) (SEE DETAIL D3fig) I I I I \\ \ ESE• 2 2 PROPOSED 2 CONTOURS (TYP) i \ \ \ \ \ \ \ \ \ \ 1 I ( — — / / 1 I \ \ / PROPOSED CONCENTRATED FLOW OUTLET (TYP) (SEE DETAIL D3.06) %1. N PROPOSED LAYDOWN AREA PROPOSED TEMPORARY INLET PROTECTION (TYP) (SEE DETAIL D3.03) I / �• i _ \ \ \ \ `yS�ys / I .►. .�. .�. \ PROPOSED 50'x25'x12" CONSTRUCTION ENTRANCE Nv1 TYP SEE NCDOT DETAIL 1607.1 i \ \ II \ \\ \\ \ \\ \ \ \\ \` \ // °�� J' J' ��`�'�\ �• (CONSTRUCTION ENTRANCE TO BE MAINTAINED T V CC AND ADDITIONAL STONE ADDED ON REGULAR / / / \ \ \ \ ` \ ♦ ,— Gp I I (� O C BASIS AS NEEDED) \ \ / ,•••••/ •V •V •V \ TO BE INSTALLED FOLLOWING STREAM PIPE `� / / / I \ \ \ \ \ \� \ \ ♦ y y ' F� �' INSTALLATION / / / I / \ \ \ \ \ \ ( LATITUDE: 35.9661 _ ✓ _ � i \�\ LONGITUDE: 82.1159 PROPOSED STORM PIPE (TYP) / / , / J l I l I I 1 \\ \\ \\ \ \ \\ ♦�\ \ ♦ 1 41 \\ v ~• (SEE TABLE AND DETAIL D4.01) i / / /r / �/ / II I1 \ \ \ \ \ \� \ \ I\ y \ \\ \\ ♦ \ �\ I II 40 ,�' ` /�� // / /� •••, \ \ \ \ �� \ \\ \\� ♦ /J PROPOSED LIMITS OF DISTURBANCE (TYP) PROPOSED STORM STRUCTURE (TYP) (SEE TABLE & DETAIL D4.02) \ /� / / / ; /' // i/ �,` \ \ \ \ \ \\ • \ ` �� \ \\ \ EXISTING 30' STREAM BUFFER (FROM TOP OF BANK) EXISTING CRANBERRY BRANCH CLASSIFICATION: C;Tr / / , ` / / \ a' \ \ • \' \ \ \ \ I I RIVER BASIN: FRENCH BROAD % \ a \ \ \ I \ PROPOSED TEMPORARY SKIMMER BASIN 'A' (SEE SHEET C932) \ \ s I STORAGE SURFACE AREA. 14,796 SF STORAGE DEPTH: 2' / i' / / / ' \ \ \ \\\\\ \\ MAX. SIDE SLOPES: 2.1:1 CONTRACTOR SHALL CONVERT TO WET POND 'A' ONCE SITE IS \l STABILIZED AND APPROVED BY NCDEQ ♦ \ p 1001, > 1 PROPOSED PERMANENT RIP RAP APRON 'JO' �• •'• LENGTH: 20.0' O 0 WIDTH AT FES: 7.5' WIDTH AT END: 23.0' �� l� , o•• I \I o DEPTH: 18" PROPOSED SILT FENCE — / \ I I I ys� ' +� l� I I STONE CLASS: B (TYP) (SEE DETAIL D3.02) ;\I �� / r �Jl �\ i (SEE DETAIL D3.09) r � PROPOSED DOUBLE ROW SILT FENCE (TYP) — + _ — + / N \ CDC INSPECTIONS HOTLINE: 828-771-4755 OR INSPECTION@CDCGO.COM ICJ — p ,1•Mt��=apt►�� i � .' '62 If ���► r�li�ryr �r• LO I N I I what's below. _U"'-"'P_ 111 before you dig. NORTH GH GRADING & EROSION ONTROL PLAN PHASE 2 GRAPHIC SCALE 0 15 30 60 120 fl w V cn Q / J z O Q J _JO J o J o 0 Oz O O_ V J U") x Ln 00 O 0' w ' ` V (n N N N Q M ♦ ) �,/ z Q o _ 0 z o Q W Lr �Q _U � J �� zm O 0 0 �o 0 U m p o (A J J ,n > CO� C:) Of W W �, Y Q M W m Z UM G 0 U Ei U o oCD 0) U n] N �rtII CO Q 0 � U 00 V s W) V � 0, L u•�M N r }a a C E •U 0 (D o a: Qr oar- UNhe 0 U U) L0 L0L0_0 V 0 � N O 06 00 M N � U 00 C 1 V1 F� U t a o 00 N I--�--�i �I 3�z a 0 C _ m •> O od U a 4 Q 2N N= a a a z LL m �aa N w w a Jia w3 QQ a �i c� 51c+ QIO a 5 C.) 3 w `w U m Z This drawing is the property of Cope Associates, Inc and is not to be reproduced without prior written authorization. This drawing is intended to be used only for the project and site specifically identified. All design information are the copyright of Cope Associates Inc. © 2020 REVISIONS NO. DATE DESCRIPTION 0 11/04/221 ISSUED FOR BID 1 12/091221 ADDENDUM 3 DATE: 12/2/2022 DRAWN BY: JCP -vain Wr� ZaJ- tn- W- - off = �Q ' �'O °°°° 4J //I/III DWG NO. C302 PROJECT NO. 12208 ( IN FEET ) 1 inch = 30 ft. FULL SHEET SIZE: 36"X48" NOTES 1. SEE UTILITY DETAIL SHEETS FOR ALL GENERAL WATER & SEWER NOTES. CONTRACTOR RESPONSIBLE FOR INCLUSION OF DETAILS SHEETS WITH ALL UTILITY PLANS. 2. WATER METERS ARE TO BE PLACED MAXIMUM OF 5' OFF EDGE OF PAVEMENT/SIDEWALK. WHEN A UTILITY STRIP IS PRESENT, METERS SHALL BE INSTALLED WITHIN STRIP. WHEN SIDEWALK IS CONSTRUCTED AND NO STRIP IS AVAILABLE, SERVICE LINES CROSSING SIDEWALK SHALL BE CONSTRUCTED WITH PVC SLEEVE EXTENDING 6" ON EITHER SIDE OF SIDEWALK PER SPRUCE PINE STANDARDS AND SPECIFICATIONS. 3. CROSSINGS TO MAINTAIN REQUIRED VERTICAL SEPARATION. CONTRACTOR TO CONTACT ENGINEER ON ANY CROSSING THAT DOES NOT MEET THIS SEPARATION, OR SEPARATION IS CLOSER THAN 1'. REFER TO GENERAL NOTES ON SEWER DETAIL SHEET FOR SEPARATION REQUIREMENTS BETWEEN UTILITIES. 4. TO SCHEDULE THE REQUIRED INSPECTIONS ON ALL WORK, CALL THE CIVIL DESIGN CONCEPTS INSPECTIONS HOTLINE AT 828-771-4755, OR EMAIL AT INSPECTIONS@CDCGO.COM. FAILURE TO SCHEDULE INSPECTIONS MAY RESULT IN UNCOVERING OR REDOING WORK. 5. TYPICAL EASEMENTS FOR WATER/SEWER LINES LOCATED OUTSIDE ESTABLISHED UTILITY EASEMENTS OR ROAD RIGHT-OF-WAYS SHALL BE AS SHOWN. THE ENTIRE WATER/SEWER EASEMENT MUST BE CLEAR AND REMAINED CLEARED OF TREE PLANTINGS, EXISTING TREES, AND ANY PERMANENT STRUCTURES. 6. NO PORTION OF THIS PROJECT LIES WITHIN THE 100-YR FEMA FLOODPLAIN. STORM LEGEND EXISTING STORM PIPE - - - - - - - PROPOSED STORM PIPE - - - - - - - - PROPOSED ROOF LEADER COLLECTOR ----------------- PROPOSED HEADWALL L PROPOSED CURB INLET STRUCTURE PROPOSED JUNCTION BOX PROPOSED FLARED END SECTION A,, PROPOSED RIP -RAP APRON STRUCTURE TABLE (INVERTS BASED ON 2D LENGTH TO INSIDE EDGES) STRUCTURE STATION STRUCTURE DETAILS DEPTH DESCRIPTION RIM 2732.4 N/A INV. IN 2727.7 (F1-Al) Al 10+34 INV. IN 2727.3 (A2-Al) 5.2 f JUNCTION INV. OUT 2727.2 (Al -AO) RIM 2747.6 A2 10+97 INV. IN 2733.5 (A3-A2) 14.3't CURB INLET INV. OUT 2733.4 (A2-Al) RIM 2749.0 INV. IN 2733.9 (A4-A3) A3 11+67 INV. IN 2735.0 (A3X-A3) 15.2't JUNCTION INV. OUT 2733.8 (A3-A2) RIM 2748.8 A3X 10+69 INV. OUT 2742.9 (A3X-A3) 5 9' f CURB INLET RIM 2747.0 A4 12+51 INV. IN 2734.4 (A5-A4) 12.7'f CURB INLET INV. OUT 2734.3 (A4-A3) RIM 2746.2 A5 12+78 INV. IN 2735.0 (A6-A5) 11.8'f CURB INLET INV. OUT 2734.5 (A5-A4) RIM 2747.6 INV. IN 2735.5 (A7-A6) A6 13+65 INV. IN 2736.2 (El-A6) 12.3'f CURB INLET INV. OUT 2735.4 (A6-A5) RIM 2748.3 A7 14+77 INV. IN 2736.2 (A8-A7) 12,2'f CURB INLET INV. OUT 2736.1 (A7-A6) RIM 2746.1 INV. IN 2736.8 (A9-AB) A8 15+75 INV. IN 2737.5 (K1-A8) 9.4't CURB INLET INV. OUT 2736.7 (A8-A7) RIM 2747.0 INV. IN 2737.4 (A10-A9) A9 16+67 INV. IN 2737.9 (B1-A9) g 7 f CURB INLET INV. OUT 2737.3 (A9-AB) RIM 2748.0 A10 17+35 INV. IN 2738.2 (A11-A10) 10.3't CURB INLET INV, OUT 2737.7 (A10-A9) RIM 2744.5 A11 17+90 INV. IN 2738.8 (Al2-A11) 6.1'f CURB INLET INV. OUT 2738.5 (A11-A10) RIM 2744.5 Al2 18+13 INV. OUT 2740.4 (Al2-A11) 4.0'f CURB INLET RIM 2748.4 B1 10+70 INV. IN 2738.7 (132-81) 9.9'f CURB INLET INV. OUT 2738.5 (B1-A9) RIM 2750.8 INV. IN 2740.0 (B3-B2) B2 11+93 INV. IN 2740.0 (D1-B2) 11.0'f JUNCTION INV. OUT 2739.9 (B2-B1) RIM 2749.7 B3 12+21 INV. IN 2742.7 (64-133) 7.9'f CURB INLET INV. OUT 2742.8 (63-132) RIM 2749.3 B4 13+32 INV. OUT 2746.0 (B4-B3) 3.4't CURB INLET RIM 2740.9 Cl 11+31 INV. IN 2735.2 (C2-Cl) 6.0't OPEN THROAT INV. OUT 2735.1 (Cl-CO) N/A RIM 2746.3 C2 12+55 INV. IN 2738.3 (C3-C2) 8,3'f OPEN THROAT INV. OUT 2738.2 (C2-Cl) RIM 2749.5 C3 14+62 INV. OUT 2744.E (C3-C2) 5.4'f OPEN THROAT RIM 2751.2 D1 12+02 INV. OUT 2747.8 (D1-B2) 3.5't YARD INLET RIM 2749.7 E2 10+91 INV. IN 2745.9 (E3-E2) 4.0't CURB INLET INV. OUT 2745.9 (E2-El) RIM 2750.7 E3 11+18 INV. OUT 2746.9 (E3-E2) 4.0't JUNCTION RIM 2740.2 INV. IN 2733.7 (11-F1) F1 11+84 INV. IN 2733.0 (F2-F1) 7.3't CURB INLET INV. OUT 2732.9 (F1-Al) RIM 2741.0 INV. IN 2734.1 (H1-F2) F2 12+16 INV. IN 2733.6 (F3-F2) 7.5'f CURB INLET INV. OUT 2733.5 (F2-F1) RIM 2739.2 F3 12+40 INV. IN 2734.5 (F4-F3) 4,8'f OPEN THROAT INV. OUT 2734.4 (F3-F2) RIM 2746.0 F4 13+75 INV. IN 2738.6 (F5-F4) 7.5'f OPEN TROAT INV. OUT 2738.5 (F4-F3) RIM 2749.9 F5 15+06 INV. IN 2740.0 (F6-F5) 10.0't CURB INLET INV. OUT 2739.9 (F5-F4) RIM 2749.5 INV. IN 2741.2 (F7-F6) F6 15+76 INV. IN 2741.5 (G1-F6) 8,8'f GRATE INLET INV. IN 2741.2 (L1-F6) INV. OUT 2740.7 (F6-F5) RIM 2749.5 F7 16+87 INV. IN 2742.6 (F8-F7) 7.1'f GRATE INLET INV. OUT 2742.4 (F7-F6) RIM 2749.1 F8 17+24 INV. IN 2743.2 (F9-F8) 6.1'f YARD INLET INV. OUT 2743.0 (F8-F7) RIM 2751.9 F9 18+12 INV. OUT 2747.1 (F9-F8) 4,9't YARD INLET RIM 2750.0 G1 10+48 INV. OUT 2745.7 (G1-F6) 4.3'f YARD INLET RIM 2748.2 H1 10+75 INV. IN 2743.0 (H2-H1) 5.3'f YARD INLET INV. OUT 2742.9 (H1-F2) RIM 2751.4 H2 12+44 INV. IN 2747.5 (H3-H2) 4,2'f YARD INLET INV. OUT 2747.2 (H2-H1) RIM 2751.8 H3 13+31 INV. OUT 2748.4 (H3-H2) 3.4't YARD INLET RIM 2737.8 11 10+50 INV. IN 2734.4 (12-11) 3.4't CURB INLET INV. OUT 2734.4 (11-F1) RIM 12 10+83 INV. 35.1 OUT 2735.1 (12-11) 3.9'f CURB INLET RIM 2727.0 A 10+97 INV. OUT 2718.5 (J1-JO) 8 5't JUNCTION RIM 2747.0 K1 10+26 INV. IN 2739.6 (K2-K1) 7.4'f CURB INLET INV. OUT 2739.5 (K1-A8) RIM 2749.5 K2 11+01 INV. OUT 2745.0 (K2-K1) 4.6't CURB INLET RIM 2751.8 L1 10+63 INV. IN 2742.0 (L2-L1) 10,0't YARD INLET INV. OUT 2741.8 (L1-F6) RIM 2751.9 L2 11+09 INV. OUT 2742.4 (L2-L1) 9.4't YARD INLET RIM 2739.6 Z1 10+44 INV. IN 2730.8 (Z2-Z1) 8.8't CURB INLET INV. OUT 2730.8 (Z1-ZO) INLET/OUTLET TABLE (INVERTS BASED ON 2D LENGTH TO INSIDE EDGES) STRUCTURE STATION STRUCTURE DETAILS DESCRIPTION AO 10+08 INV. IN 2725.9 (Al -AO) FES CO 10+36 INV. IN 2734.1 (Cl-CO) FES JO 10+43 INV. IN 2718.2 (J1-JO) HEADWALL YO 10+04 INV. IN 2724.4 (Y1-YO) HEADWALL Y1 10+32 INV. OUT 2724.6 (Y1-YO) HEADWALL ZO 10+69 INV. IN 2730.5 (Z1-ZO) INV. IN 2730.5 (EX-ZO) HEADWALL Z2 10+15 INV. OUT 2731.1 (Z2-Z1) HEADWALL , zr,47' \ \ 1 \ PROPOSED WATER CROSSING I \ \ \ \ \f \ \ \ \ \ (12 MIN. VERTICAL SEPARATION) do\ I \ \ \ \\ \ // /� r/ r/ / // � � I I I I I � I II II �� � \�• \ \ \ I / / /•�/ r/ / / I I I I I I I I I I\ N \� �\ \\ PROPOSED STORM BYPASS PIPE INSTALLED DURING ROUGH GRADING (SEE SHEET C301) r\ / / / r / / I I I I I I I I I I I I I \TP �/ � // I /I I I � I I I I � I II I I I II I II \\ /I \\\'• \ \\\ / PIP � // J I I I I I I I I I 1 1 \ \\ \\ \ PROPERTY LINE (TYP) I \• \ \ \ I l \ / i PROPOSED SEWER CROSSING I I I I II II I \I \ I \ ' \ \ - - - - -p (6" MIN. VERTICAL SEPARATION) \ I I I \ I m Z2 STORM PIPE (TYP) I I I \ I s \ �. ------ Cl W ores 10V �5 C2 I- - ■ ■77Al2 M \ \ 1 \ \ ` \ PROPOSED SEWER CROSSING ---0 - - / p ■ A _ \ (6" MIN. VERTICAL SEPARATION) 277 � j zo ? m / r/ 11 I I I I I � \ \ I 2280� ♦ /j I 62 j ♦ �� I I I I I r O / / /�\ \ \ \ \ 1 \ \ \ \ \ \ I I �I ♦ I / 1 L 1� \ \ \ \ PROPOSED 12" ROOF LEADER \\\\ I 00 1 yW' y \ Ind. 27MIN. SLOPE 1% \\ C3 n (TYP) (SEE DETAIL D4.06) .97 S \ \ \ • I I I" \ \ \ \ \ \ \ \ \ PROPOSED 12" ROOF LEADER \ �\ a MIN. SLOPE 1% A9 / \ I I I \ \ \ \ _ _ - - \ (TYP) (SEE DETAIL D4.06) \> I•I , I / \ 1 I I \ \ e \ \ ♦ // / / / / / .gy.�. a+ q + + + \ \ \ I .�\/ // // � / I I I I I I I \ \\ \\ \°, \ \ I \ \\ � �\ °� \� a j// /// // � // / // // � / I � .� ��I �I\ I/.i• .� - �•��.� �• .� � \ \ \ I \ \\\ 1000, / PROPOSED RETAINING WALL \ \ \ \ // \ \\ \ \ \ \ I \ \\/ K2 / �// / MAX HEIGHT 13' �' PROPOSED YARD INLET \ \ \ \ \ \ - - - - ° - / / / / �/ r / (TYP) (DESIGNED BY OTHERS) (TYP) (SEE DETAIL D4.04) I \ \ D1 // / / ,�� I I I I I I II I \ � I \ \ •d � / / / / / / / // / A8 �� / �• �• \� . \I �• �• �• \\ \ \ \ / l l l l N � � 1 I I I I I \ I \ \ \ \ • / / / / / // / / / r / v .v � v � •I .v .v .v \ \\ \ \ \JAJ V) l / N�'� l l /l I I 1 y ° I 11 II 1 \ � I \ \ - - - '<% - -/ / / / / �/ / / // .,. .i• y i� .(L• .i• .i• .i• \ \ \ / / / r ,�� � I I I I • \ I 1 ROOF LEADER (SEE ARCHITECT DRAWINGS FOR � � � / / / / / - / DOWNSPOUT LOCATIONS) ,\ / / I F7 \ 1 i � I / i / � �� - G � •v •v � \ •v •v \ \ 1 / / / / / N I I I II I \ 1 I\ \ \ \\ I ( / � ° • , - / � / •v .v .v � 03 I \ \ \ 2 11 / �. �. �. \ � .4 \ \ IEEE �752\0 1 / Rim 2731.78 i r♦ / / 1 \ \ \ \ 1 \ \ \ \ \ \ \ \ 1 ( a ; 1 - -/ / I .v .v \ \ .v .v .v \ \ \ \ Inv. 2726.18' %k � \ I I 2 I II �/I D 1100 a \ \\\\ \ \\ \\ \ \ \ \ \ \ I I \ / I \ r N -L--\ To a) I \ I \ PROPOSED 12" ROOF LEADER \ \ \ \` •` \ r o r ✓ / I ; \ \ I \ n MIN. SLOPE 1% (TYP) (SEE DETAIL D4.06) A CE oo I / /A7 / / / r I \ \ \ \ \ \ \ \ /� l •v •v •v I \ 1 C ♦ E1 ♦< m i' / / / / / 1 \ \ \ \ \\ \ \ \ \ \ \\ �♦ \ N I J, �J, \ I I EXISTING 30' STREAM BUFFER / i / / / I r / I I I \ \ \ \ \ \ \ \ \ \ ♦♦X \ I \ \'. \ (FROM TOP OF BANK) M / W/ PROPOSED 12" ROOF LEADER �� / /------1'------- MIN. SLOPE 1% (TYP) (SEE DETAIL D4.06) / / / , \ \ \ \ \ �a\ \ \ \ \ \ \ \ \ \ \\ \\ \ I \\ I EXISTING CRANBERRY BRANCH 'UP) CLASSIFICATION: C;Tr N \ \ \ RIVER BASIN: FRENCH BROAD \ � I _ �I / ♦�� I \ \\ \ \\ \ \ \ \ \ \ \ \ \ \ N \ I A3X \ \ \\ \ \ \ \\ \ II I 111 2 \\\ \ \ PROPOSED WET POND "A" (SEE DETAIL D4.08) PROPOSED CONTROL STRUCTURE 1 / / \ �• se (SEE DETAIL D4.06) (PROPOSED EE DETAIL STORM STRUCTURE D4.02) (TYP) / / - / / j / �/ , / VICINITY MAP (NOT TO SCALE) MITCHELL COUNTY SCHOOLS 72 LEDGER SCHOOL ROAD BAKERSVILLE NC 28705 KIM HODSHON (828)766-3437 CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NC 28801 MICHAEL CAIN, P.E. (828) 252-5388 BLACKROCK SURVEYING & LAND DESIGN, PC PO BOX 8302 ASHEVILLE, NC 28814 ROBERT K. BRADY, JR (828) 225-4341 COPE ARCHITECTURE 2607 KINGSTON PIKE, SUITE 5 KNOXVILLE, TN 37919 JAKE MCREYNOLDS (865) 694-9000 PIN: 0872-70-6960 ADDRESS: 5085 S. NC HWY 226 BAKERSVILLE, NC DEED BOOK/PAGE: 608/934 SITE ACREAGE: 14.93 ACRES ZONING: SNOW CREEK TOWNSHIP SETBACKS: N/A DISTURBED AREA: 12.26 AC PARKING CALCULATIONS: HANDICAPPED SPACES: SPACES REQUIRED: 5 SPACES PROVIDED: 5 VAN SPACES REQUIRED: 1 SPACES PROVIDED: 5 VEHICULAR MINIMUM REQUIRED: N/A AMOUNT PROVIDED: 117 BUILDING DATA: BUILDING DESCRIPTION HEIGHT GFA PROPOSED MIDDLE SCHOOL XX' 70,580 SF IMPERVIOUS CALCULATIONS: IMPERVIOUS PERVIOUS PRE -DEVELOPMENT: 0.11 ACRES (1%) 14.82 ACRES (99%) POST -DEVELOPMENT: 3.54 ACRES (24%) 11.39 ACRES (76%) SOIL TYPE EcC, EcD, BdA, Ud, SaB, EdE, EcC, & ScC SOIL GROUP: B, C, &D PIPE TABLE (SLOPES BASED ON 2D LENGTH TO INSIDE EDGES) PIPE NAME SIZE LENGTH SLOPE MATERIAL 1-AO 24' 5.5% HDPE A2-Al 30" 60' 10.01 H PE A3-A2 30" 67' 0.5% HDPE A3X-A3 5' 66' 12.1% HDPE A4-A3 30" 80' 0.5% DPE A5-A4 30" 24' 0.5% HDPE A6-A5 24" 85' 5% HDPE A7-A6 24" 109' 0.5% HDPE AB-A7 24" 96' 0.5% HDPE A9-A8 24" 90 U.5% HDPE A10-A9 24" 65' 0.5% HDPE All-A10 18" 52' 0.5% HDPE Al -A11 15" 20' 8.3% HDPE B1-A9 18" 67' 0.8% HDP B 2 - B 1 15' 119' 1.0% HDPE B3-B2 15" 25' 11.1 % HDPE 134-133 15" 109' 3.0% HDPE Cl -CO 30" 92' 1.1 % HDPE C2-Cl 30" 121' 2.5% HDPE C3-C2 30" 203' 3.1% HDPE - 2 15" 199' 3.9% HDPE El-A6 15" 23' 9.9% HDPE E -E1 15" 63' 11.7% HDPE E3-E2 15" 23- 4.5% HDPE F1-Al 24" 181' 2.9% HDPE F2-F1 24" 30' 1.8% HDPE F3-F2 24" 20' 3.7% HDPE F4-F3 24" 131' 3.0% HDPE F5-F4 24" 128' 1.0% HDPE F6-F5 24" 67' 1.0% HDPE F7-F6 18" 109' 1.0% HDPE F8-F7 15" 35' 1.1 % HDPE F -F8 12" 86' 4.5% HDPE G1-F6 15" 46' 9.1% HDPE H - 2 18" 73' 12.0% HDPE H2-H1 18" 166' 2.6% HDPE H3-H2 15" 86' 1.0% HDPE 11-Fl 15" 47' 1.4% HDPE 12-11 15" 30' 2.5% HDPE J1-JO 30" 51' 0.6% HDPE K1-AB 15" 23' 9.0% HDPE K2-K1 15" 72' 7.5% HDPE L1-F6 12" 60' 1.0% HDPE L2-L1 12" 44' 1.0% HDPE 11-YO 18" 25' 0.8% HDPE PROPOSED STORM PIPE (TYP) I \ - 2��'p ' / / �� /000, (SEE TABLE AND DETAIL D4.01) _> _> i -> IV I I � \ k I c9 \ \ I I i I _ - J PROPOSED PERMANENT RIP RAP APRON 'AO' I / _ I I 8S, \ \\ \ \ I \ LENGTH: 23.0' WIDTH AT FES: 9.0' WIDTH AT END: 26.0' DEPTH: 18" STONE CLASS: B (SEE DETAIL D4.05) 01 \ I / / / _ F1 - CDC INSPECTIONS HOTLINE. \ / 12 - _ - - AO _ l 828-771-4755 OR INSPECTION@CDCGO. COM -ILI N` (IV / c� 273 cr Y1 Yo / / / Know what's below. Call before you dig. NORTH - - -I = STORM DRAINAGE PLAN SoUth N.C. -L-L-Whway 226 / / / / `\ GRAPHIC SCALE Variable WINVper N. C y/ DOT Project 8.18 5 7 30 0 15 30 60 120 ( IN FEET ) 1 inch = 30 ft. U) J O OJ O U 0 CnO oLL �+ z J U Q a ♦ V^ W �c� a Wz J O0 0 0 J W 0O UM G Ln 0 r` �00 N N N Q >_ Z Q J c� Q _U U� z� 0 �z Dw 0 U) J Ln > COCn C:) Of LnW Y Q m 0 U Ei o a0i o CD 0) U rn a�i �Q LO 0 00 V s W) V � 0, N CIO ° _ '7u 0 as O n � QJ Qr O %0 C UNhe 0 U N �LO-a � v c � N O C600m N � U V 1 V1 U t U o 00 00 �I 3�z F-�--I a 0 C O �> O d U a 4 <U N�a bu rna a -- a z x N w w a m u=i° r oLL w3 Q Q a - c� •mac a a� 5 9 UaU I w w U m Z This drawing is the property of Cope Associates, Inc and is not to be reproduced without prior written authorization. This drawing is intended to be used only for the project and site specifically identified. All design information are the copyright of Cope Associates Inc. © 2020 REVISIONS NO. DATE DESCRIPTION 0 11 /04/22 ISSUED FOR BID 1 12/09/22 ADDENDUM 3 2 12/14/22 AGENCY SUBMITTALS DATE: 12/2/2022 DRAWN BY: JCP zm Way= W� Za_J to pa LU = - ° 0 0N aaa °�``,';IL IL DWG NO. C401 PROJECT NO. 12208 FULL SHEET SIZE: 36"X48" 2760- 2760 o O o 0 0 0 0 0 o r2 0 0 0 0 0 0 0 0 0 + + + + + + + + + + O N M V un [O r W 00 STORM A 2760- FINISHED GRADE (TYP) 27 -2760 EXISTING GRADE (TYP) I M Q 274 -2740 �QE a0 a ao _ X a+n� mN N � O a � .. a.,;a N M �? Q Q 273 -2730 IxM Q+NZ -ZO K 0Z» a �--ZZ 2720- 272C 2710- -2710 O O1 o cfl 0 0 STORM A3X V) 2780- 2780 EXISTING 30' STREAM BUFFER m (FROM TOP OF BANK) N 2 2 2 2 2 2 2 O O O O O N o O o 0 o cfl + + + + + + O N STORM C FINISHED GRADE (TYP) 2760- 23LF-15" HDPE ® 9.9X 2750— MA EXISTING GRADE (TYP) N Q I I QIv 27 tn N 0 -HM1 M N '0 a N N Q+n NZ aZO „ a 0- a A129?? 2710- 2700— O O 27 27 ,A, 27 27 27 27 O O O O M O + N M M STORM B 2760 23LF-15 HHDPE a N W y° , 0 LL W 2740 -H n I W ON rn n w±� =O 0 N N asa n 1 -- 0: w +n H a ? 10 Q0. N ' =O W I " 0— a -Z Z tq 2730 MM n IN mn N N a W +n H NZO a„ aCIL In 2720 2710 2700 O 0 W STORM E O -H M N N m +nH N =O 0. oln 12Z STORMED] CDC INSPECTIONS HOTLINE: 828-771-4755 OR INSPECTION@CDCGO. C'OM Know whch'aIOW. Cal before you dig. STORM PROFILES 0 20 40 90 "O!!!� 1 inch = 40 ft. (H) 0 4 8 16 "O!!!� 1 inch = 8 ft. (V) 770 760 750 740 730 720 710 W J p pJ =p U p _ r- 00 ` 0 N N N Q Lp V ♦ < z ao J LU CD < 0 p J �� z� U a �Lj J J LnJ Ln � Ln� J �w Ln W 00 Q 07 U M E O O w 7 U o w o �- O L O rn w CID 0� w co 3 U s � iCq)0 �CL 0) +5 C C v O C .o rn~ V) C w QY NP,-. x O co C U cV tO E O w rp -q r � ul) N ti O N N +� N CN U 00.0 vJ O L � U 3 Z W � vw C: 0s� U V4 z 2 iu ry V U u umi z o� ww m m S y s a= Q� v� 0 u �an zaa 33 F8 5-5A,2-0)00,,n)) ° a 3 3 m ti v z w u v w m U Z This drawing is the property Cope Associatesi Inc and Is not be reproduced without prior written authorization. This 11 Is intended to be used only far a project and site specifically identified All design Inflormatim are the copyright of Cope Associates Inc. @ 2020 REVISIONS NO. DATE DESCRIPTION 0 11 /04/22 ISSUED FOR BID 1 12/09/22 ADDENDUM 3 2 12/14/22 AGENCY SUBMITTALS DATE: 12/2/20 DRAWN BY: 'CP Q) � DODO d�o�= - r o N Q r _Z o J- - U o� N Lv - °Y0 o �� Omli DWG NO. C 4 0 2`1 PROJECT NO. 12208 SHEET SIZE 48 r 2790 790 2780 / 2770 2760 EXISTING GRADE (TYP) / 35LF-15" HDPE @ 1.1 % 20LF-24" HDPE @ 3.7% 2750—/ FINISHED GRADE (TYP) 3OLF-24" HDPE @ 1.8% / -12' ' HDP g6L 7-1 � 109LF-18 HDPE @ 1.0% 274 67LF 24" HDPI ao ILL` 128LF 24" HDP @ 1.0% .. r I 1 � IIZILL ILL HDPE 3.0% r i LL LL I ....LL i ao L� 1 I °° ILL LL �v Ln 1 I I I LriC� LL v co +IN N O N� N N ' . �.� r N +1 Ki r. ^ O ri) N ILLN Ln 0 r+00 �N cfl N •• NOir N �� O O o0 + H 0- O rNZ 2 7 3 181E —24' HD LL O -H Ln v N ^_ ^ �+�N �� oMr- co LL vN N oQ�z �ILL O �� z > ^Q _^ N N L` u? N O Z U +� N Z Z O O G HO> 0-(nHZ 0 Z 0 HO» 1 LL Li 1 o .. u7 N .. 0- (n z z ^ I N� ILL LL Qo> ..a M+nN "rn LLN� CO~ as 1 1 +I�ri� rON N.. 272 1 Q NNN o �o LLa �N o�rN _ CNN N+ 0-0 LAN +II��14 C-4 7: ZZ0 ��NNN 0_.. — O 0_ O +r)N a_ V)Z Z Z — ? O Oad- 0- z z Ln 271 0 -7n —. 2760— —2760 EXISTING GRADE (TYP) 2750— —2750 47LF-15" HDPE @ 1.4% FINISHED GRADE (TYP) 274 �4-2740 273 - 2730 I 1 Li N O) N -H r4 r raj "' O r N Nr N +toN H ON �Or .. +� NZ O 272 N Z a 2720 �.. -0 cr 0 � j j j 0- V) z D- �?zz 271 2710 O M O 00 + + O o STORM O O O O O O + + + N M STORM F EXISTING 30' STREAM BUFFER (FROM TOP OF BANK) PROPOSED PERMANENT RIP RAP APRON 'AO' LENGTH: 23.0' WIDTH AT FES: 9.0' WIDTH AT END: 26.0' DEPTH: 18" STONE CLASS: B (SEE DETAIL D3.09) 2740— N 2730 m N 2720— m 0 m 1 2 71 (/) N - ao N N ON O N Z m oaaj acne H O 27 m N 269 0 O + 0 STORM J FINISHED GRADE (TYP) 51 LF-30" HDPE @ 0.6% —2730 EXISTING GRADE (TYP) 720 d 2710 a 4 N� !:Z FZ N r � 2700 `2690 r 0) + 0 276 275 274 aQ� 273 00Lo -:n Ln L6 +1 co 1- rUjr� K) 00+CNN < Ln r NZZ 00 0- 0 <ojjj 0- co 272 AFA O O + O STORM K 760 750 740 730 720 1780 1770 1760 1750 ? 740 1730 ?720 ? 710 —2700 O N O + + co Co 0 O 0) O 0 O + + + O STORM L 2800 2800 EXISTING GRADE (TYP) 2790— 2790 2780— 2780 2770 770 27E 760 275 750 274 LO ILL 740 273 Uri +1't O r 00 N O �tr� N D � O 730 � 0 j 0- cn 272 720 O 00 o -4- + + O O STORM G 2750— FINISHED GRA�(Typ)l 25LF-54" RCP @ 1.2% 2740- 273 272 271 271 0 O + O 2770 EXISTING GRADE (TYP) D / 1 l- FINISHED GRADE (TYP) !8r6,LF- 5" HDPE @ 1.0% 166LF-1S' HDPE f\/ "'1111� I N 1 = @ N �Ln O = N r N O LJ tl rri o O _ Sao j LLnONOr cv I +�N o Ln� z LL M v z � a� O co rj O'Qoj o Ln z +I rn r7 - C0 O N N ILL C11Z O O a Of�o 0— o- Ln � z z 2750 PROPOSED SEWER CROSSING 22LF-54" RCP @ 1.2% .5' 0� EXISTING GRADE (TYP) 730 N O O 720 w i X > — J O Ln Ui U +1 O O 00nr EDLriNN ON +r O �NZZ 0- 0_�-Ojj 710 a_ V) 2700 2700 O CIN o + ++ 0 CULVERT Z1 O o O O + + N STORM H 0 0) O r + + 0 0 CULVERT Z2 CDC INSPECTIONS HOTLINE: 828-771-4755 OR INSPECTION@CDCGO. COM Know what's below. Call before you dig. STORM PROFILES 0 20 40 80 1 inch = 40 ft. (H) D 4 8 16 "O!!!� 1 inch = 8 ft. (V) 0 O + M ?760 1750 iLiol� 00 -H 00 r N L'Q� a• N C ' F 0O > D- Cn 1730 1720 2710 M + M 2740— —2740 25LF-18" HDPE @ 0.8% FINISHED GRADE (TYP) 273 —2730 EXISTING GRADE (TYP) O } 2720— 2720 1 I v +I4 O N N00N OL6N rM (6 _+N �O� }OOrNO N Z - O a .... 0 < 271 2710 � � 0 0'�O> acne ���z 2700 2700 o r O M + + CD C) CULVERT Y U) J O OJ =O U p Ln U) O r c0 CO N N N Q ao LA J Z W �a CD< 0 J z� > O [IfU 0 =o � 0 0 w � J J— J Ln 5; LnCn oof W< Lnw 00 M m co 5� G E O U N 7 o O + O !E 07 U n] rn N \rY/ c0 Q L6 O ('0 U 00 V V � � L u•�M �G vi of }a c ° _ '7u o as o �� a: Qr oar UN�k E O U N LO LO 0 LO v 0 f` N N 06 00 M N 04 U 00 0 U o 00 tA 00 'O U .� 3�z LU w X _ C m O oON U a 4 a 2 m g a 0 LL m N �aa N 2u w a r J�a a3 3 Fnue 1 w w m U 2 This drawing is the property of Cope Associates, Inc and is not to be reproduced without prior written authorization. This drawing is intended to be used only for the project and site specifically identified. All design information are the copyright of Cope Associates Inc. ©2020 REVISIONS NO. DATE DESCRIPTION 0 11 /04/22 ISSUED FOR BID 1 12/09/22 ADDENDUM 3 fl DATE: 12/2/2022 DRAWN BY: JCP �00 =Qacn ar _z°�= -UaLo U r.- y°Od DWG NO. C403 PROJECT NO. 12208 FULL SHEET SIZE: 36"X48" NOTES 1. SEE UTILITY DETAIL SHEETS FOR ALL GENERAL WATER & SEWER NOTES. CONTRACTOR RESPONSIBLE FOR INCLUSION OF DETAILS SHEETS WITH ALL UTILITY PLANS. 2. WATER METERS ARE TO BE PLACED MAXIMUM OF 5' OFF EDGE OF PAVEMENT/SIDEWALK. WHEN A UTILITY STRIP IS PRESENT, METERS SHALL BE INSTALLED WITHIN STRIP. WHEN SIDEWALK IS CONSTRUCTED AND NO STRIP IS AVAILABLE, SERVICE LINES CROSSING SIDEWALK SHALL BE CONSTRUCTED WITH PVC SLEEVE EXTENDING 6" ON EITHER SIDE OF SIDEWALK PER SPRUCE PINE STANDARDS AND SPECIFICATIONS. 3. CROSSINGS TO MAINTAIN REQUIRED VERTICAL SEPARATION. CONTRACTOR TO CONTACT ENGINEER ON ANY CROSSING THAT DOES NOT MEET THIS SEPARATION, OR SEPARATION IS CLOSER THAN 1'. REFER TO GENERAL NOTES ON SEWER DETAIL SHEET FOR SEPARATION REQUIREMENTS BETWEEN UTILITIES. 4. TO SCHEDULE THE REQUIRED INSPECTIONS ON ALL WORK, CALL THE CIVIL DESIGN CONCEPTS INSPECTIONS HOTLINE AT 828-771-4755, OR EMAIL AT INSPECTIONS@CDCGO.COM. FAILURE TO SCHEDULE INSPECTIONS MAY RESULT IN UNCOVERING OR REDOING WORK. 5. TYPICAL EASEMENTS FOR WATER/SEWER LINES LOCATED OUTSIDE ESTABLISHED UTILITY EASEMENTS OR ROAD RIGHT-OF-WAYS SHALL BE AS SHOWN. THE ENTIRE WATER/SEWER EASEMENT MUST BE CLEAR AND REMAINED CLEARED OF TREE PLANTINGS, EXISTING TREES, AND ANY PERMANENT STRUCTURES. 6. NO PORTION OF THIS PROJECT LIES WITHIN THE 100-YR FEMA FLOODPLAIN. � � I \ I I I l I / U o / I CIV / I PROPOSED ADA PARKING SPACE & A / (TYP) (2% MAX. SLOPE IN ANY DIREC I I/ I� O 00 O �o / N N I A I O/ / I I / / I / / ' 1 I / / I / / / I' I - / O/ / C / / / / i - I, l I/-zoo V', \. PROPOSED 1' CONTOURS (TYP) I I \ I \• \ PROPERTY LINE (TYP) / ' I I VTOURS (TYP) / _ - - ' -�6° ■ - - ■ ■ ■ ■ I nnnn EP 34 8 is \ \ - - ■ 4.43 6C` 40.2 EP 3 --2770 BC OIM 39.60 \ \ - 6C 50.4 �MS FG 50.5� C 50.4loo, I I II I \ S s I BC 50. M EP 50.0 SS I \ \ 50.79 I S , E 49.9 I I _49.67 / _ SW 50.1 I I I I 4.45 I I / \ \ \ SW SW 50 .5 CD / \2% • FG 5y51.7 5 I I 44 I I 8� �� 45. � S�1.6 \ \ Fc�5o.2 c sow, i , / / a I s s'1"► �?% 11 I 1-1-1 I ,Variable South N.C. Hi hw.q V 226 OT Project 8.185 PROPOSED CONNECTION TO EXISTING / ROAD (CONTRACTOR TO MATCH EXISTING ELEVATIONS) V) � / i Q 2720 / / /] F H I I \\ Rim 2731.78' Inv. 2726.18' Gt� 1 r � � C STING 30' STREAM BUFFER M ;OM TOP OF BANK) I \\ C` I I \ I I 0 I � I o I I\ CDC INSPECTIONS HOTLINE: 828-771-4755 OR INSPECTION@CDCGO. COM Know what's below. _U"fi__aRP_ Call before you dig. NORTH FINE GRADING PLAN GRAPHIC SCALE 15 30 60 VICINITY MAP (NOT TO SCALE) DEVELOPMENT DATA OWNER/DEVELOPER: MITCHELL COUNTY SCHOOLS 72 LEDGER SCHOOL ROAD BAKERSVILLE NC 28705 CONTACT: KIM HODSHON (828)766-3437 CIVIL ENGINEER: CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NC 28801 CONTACT: MICHAEL CAIN, P.E. (828) 252-5388 SURVEYOR: BLACKROCK SURVEYING & LAND DESIGN, PC PO BOX 8302 CONTACT: ASHEVILLE, NC 28814 ROBERT K. BRADY, JR (828) 225-4341 ARCHITECT: COPE ARCHITECTURE 2607 KINGSTON PIKE, SUITE 5 KNOXVILLE, TN 37919 CONTACT: JAKE MCREYNOLDS (865) 694-9000 PROJECT DATA PIN: 0872-70-6960 ADDRESS: 5085 S. NC HWY 226 BAKERSVILLE, NC DEED BOOK/PAGE: 608/934 SITE ACREAGE: 14.93 ACRES ZONING: SNOW CREEK TOWNSHIP SETBACKS: N/A DISTURBED AREA: 12.26 AC Jla:11�[eZ�71��1�1�111NP►�� Mir SPACES REQUIRED: 5 SPACES PROVIDED: 5 VAN SPACES REQUIRED: 1 SPACES PROVIDED: 5 VEHICULAR MINIMUM REQUIRED: N/A AMOUNT PROVIDED: 117 BUILDING DATA: BUILDING DESCRIPTION HEIGHT GFA PROPOSED MIDDLE SCHOOL XX' 70,580 SF IMPERVIOUS CALCULATIONS: IMPERVIOUS PERVIOUS PRE -DEVELOPMENT: 0.11 ACRES (1%) 14.82 ACRES (99%) POST -DEVELOPMENT: 3.54 ACRES (24%) 11.39 ACRES (76%) SOIL TYPE EcC, EcD, BdA, Ud, SaB, EdE, EcC, & ScC SOIL GROUP: B, C, &D FINE GRADING LEGEND BC - BOTTOM OF CURB BW - BOTTOM OF WALL EP - EDGE OF PAVEMENT RIM - RIM (TOP OF LID/GRATE) SW - SIDEWALK HP - HIGH POINT LP - LOW POINT TW - TOP OF WALL Ln 0 r` �00 N N N Q }z Q J O c� CE _" O z� O �Z Dw O U) J Ln COCn 0 0' Lnw Y Q m 0 U N 7 O U O .+U--' cD 0) U n ] �r�II 0) 0 CO Q L6 0 � U 00 V � � �G vi of }a c ° _ '7u o as O O � r U N hL ;_ 0 U N V lLO LO_0 V 0 04 N O N C6 00 M N � U 00 .. N 0 00 N 'O U �O Z x - °O° .N ON as w `w m z This drawing is the property of Cope Associates, Inc and is not to be reproduced without prior written authorization. This drawing is intended to be used only for the project and site specifically identified. All design information are the copyright of Cope Associates Inc. © 2020 REVISIONS NO. DATE I DESCRIPTION 0 11 /04/22 ISSUED FOR BID 1 12/09/221 ADDENDUM 3 DATE: 12/2/2022 DRAWN BY: JCP a o =Q -UaW Q� Za U °LU= %y°o� o 4; =�0N 1 DWG NO. C501 PROJECT NO. 12208 / ( IN FEET ) 1 inch = 30 ft. FULL SHEET SIZE: 36"X48" �\ \ PROPOSED STORM CROSSING (6" MIN. VERTICAL SEPARATION)X PROPOSED STORM CROSSING (12" MIN. VERTICAL SEPARATION) ( IN FEET ) 1 inch = 30 ft. VICINITY MAP (NOT TO SCALE) DEVELOPMENT DATA OWNER/DEVELOPER: MITCHELL COUNTY SCHOOLS 72 LEDGER SCHOOL ROAD BAKERSVILLE NC 28705 CONTACT: KIM HODSHON (828)766-3437 CIVIL ENGINEER: CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NC 28801 CONTACT: MICHAEL CAIN, P.E. (828) 252-5388 SURVEYOR: BLACKROCK SURVEYING & LAND DESIGN, PC PO BOX 8302 CONTACT: ASHEVILLE, NC 28814 ROBERT K. BRADY, JR (828) 225-4341 ARCHITECT: COPE ARCHITECTURE 2607 KINGSTON PIKE, SUITE 5 KNOXVILLE, TN 37919 CONTACT: JAKE MCREYNOLDS (865) 694-9000 PROJECT DATA PIN: 0872-70-6960 ADDRESS: 5085 S. NC HWY 226 BAKERSVILLE, NC DEED BOOK/PAGE: 608/934 SITE ACREAGE: 14.93 ACRES ZONING: SNOW CREEK TOWNSHIP SETBACKS: N/A DISTURBED AREA: 12.26 AC 91V1141Z1exeL1"11W11Its] ►1,� J1�U1NT1»��1�yJ_Til�. SPACES REQUIRED: 5 SPACES PROVIDED: 5 VAN SPACES REQUIRED: 1 SPACES PROVIDED: 5 VEHICULAR MINIMUM REQUIRED: N/A AMOUNT PROVIDED: 117 BUILDING DATA: BUILDING DESCRIPTION HEIGHT GFA PROPOSED MIDDLE SCHOOL XX' 70,580 SF IMPERVIOUS CALCULATIONS: IMPERVIOUS PERVIOUS PRE —DEVELOPMENT: 0.11 ACRES (1%) 14.82 ACRES (99%) POST —DEVELOPMENT: 3.54 ACRES (24%) 11.39 ACRES (76%) SOIL TYPE EcC, EcD, BdA, Ud, SaB, EdE, EcC, & ScC SOIL GROUP: B, C, &D STRUCTURE TABLE (INVERTS BASED ON 2D LENGTH TO INSIDE EDGES) STRUCTURE STATION STRUCTURE DETAILS DEPTH DESCRIPTION RIM 2738.1 MHA1 10+00 INV. IN 2734.5 (MHA2—MHA1) 3 9'f MANHOLE RIM 2740.8 MHA2 11+05 INV. IN 2737.1 (MHA3—MHA2) 3.7'f MANHOLE INV. OUT 2737.0 (MHA2—MHA1) RIM 2744.5 MHA3 11+75 INV. IN 2740.7 (MHA4—MHA3) 5.1'f MANHOLE INV. OUT 2739.4 (MHA3—MHA2) RIM 2748.1 MHA4 12+37 INV. IN 2741.6 (OUTLET—MHA4) 6.6'f MANHOLE INV. OUT 2741.5 (MHA4—MHA3) PIPE TABLE (SLOPES BASED ON 2D LENGTH TO INSIDE EDGES) PIPE NAME SIZE LENGTH SLOPE MATERIAL MHA2—MHA1 8" 101' 2.5% DIP MHA3—MHA2 8" 66' 3.5% DIP MHA4—MHA3 8" 58' 1.3% DIP OUTLET—MHA4 8" 68' 0.5% 1 DIP 120 U) J O OJ =O " UO U)Mrw J V) ai Z z J^ W Q J J O C) U D J J W 0O UM G Ln 0 r` �00 N N N Q }z Q J c� Q _U 0 z� 0 �z Dw 0 (A J Ln> COCn or), LnW Y Q m E 0 U N 7 CDN O + 0) U n ] �r�II U) 0 CO Q L6 0 U 00 V � 0' L u•�M �G vi of }a c ° _ '7u o (D O oar U N �k E 0 U N LO�0 L O v 0 � N N N 00 0 U 0� W U C1 V1 U r � �C O Za�� Ie < -.M G"9 6,zLL y�if W a m u=io as Jaa a3 3 FE 2 a N 0 00 00 N 'O U �O Z w z U m U 2 This drawing is the property of Cope Associates, Inc and is not to be reproduced without prior written authorization. This drawing is intended to be used only for the project and site specifically identified. All design information are the copyright of Cope Associates Inc. © 2020 REVISIONS NO. DATE DESCRIPTION 0 11 /04/22 ISSUED FOR BID 1 12/09/22 ADDENDUM 3 DATE: 12/2/2022 DRAWN BY: JCP —Q 00 J ca Qr` J- U°LU= -UaW %y°off CD DWG NO. C601 PROJECT NO. 12208 FULL SHEET SIZE: 36"X48" 6' HIGH 16' WOODEN FENCE 2"-3" S9.5B OR S9.5C 11" 825.08 0R B25.00 y r �1-p ° Q SURFACE COARSE BASE COURSE Q 4 ° a ° p O p p °Q �� U e` ° p _ExisTiNo ExisriNB cow=z Xa° °X XA 4000 PSI CONCRETE ° ° , H , " wd ��x ° a ®° ° e WITH 6"x6"/1.4x1.4 W.W.F. 0" x 2, 0„ 1 6" CABC STONE �=~xw a p ° 6" DIA. STEEL BOLLARD 2 >> G� p 8" 4009 PSI CONCRETE ° TYPICAL SEE DETAIL w SCE SF 9.5C ASPHALT SLS WITI1 #4 REBAF� @ ( )( )a CIO ° 12 O.C. EACH WAY UK In p �o CABC STONE COMPACTED ° O ----TCABC STONE COMPACTED TO 100% OF MAXIMUM p ° WOODEN SWING GATE � LABORATORY DRY DENSITY p ° TO 100% OF MAXIMUM (° ° ASTM D 1557 OR AASHTO Q LABORATORY DRY DENSITY T 180 p o x w PAVEIENT REPAIRS ON ROADS TO BE RESURFACED O J u (ASTM D 1557 OR AASHTO ) co ° ° 12„ �,-4" 7 4" {PIPE IS PLACED UNDER EXISTING PAVEINENT) = O T 180) w Q a ( > Q ° Q 15" V-7" V-7" 0 V Q p p ° p !� 1S" 1'-10" 7' 10„ W V/ O o \/\ ° it „ v NOTES: ✓// // // // // // // // // // // // // // // i o " 2" COMPACTED �i\/\ MINIMUM 24" COMPACTED 30' 3''1 8 -i SURFACE COURSE # c Q ° 1. SIGN SHALL HAVE WHITE LETTERS ON A RED REFLECTIVE BACKGROUND. // // // // // // // // // // // // // //\� 0 38" 30 g" W-8" ML N z SUBGRADE TO MINIMUM 98% w o }- \ ° SUBGRADE TO MINIMUM 98% 11° s25.oe OR e25.00 W � .. �/e, Q OF THE MAXIMUM DRY w p ° 42" 4'-5" 10'-5" BASE COURSE-7/ p LC U) 0 2. ALL SIGNS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE MANUAL OF OF THE MAXIMUM DRY w o DENSITY USING THE a q� 8" 4000 PSI CONCRETE " " ____ ____ a� > w = UNIFORM TRAFFIC CONTROL DEVICES MUTCD PUBLISHED BY THE FEDERAL HIGHWAY DENSITY USING THE o ° 49 8 -0 11 -O a C Q (MUTCD) STANDARD PROCTOR TEST J SLAB WITH #4 REBAR @ EXISTING EXISTING az = a � c� ADMINISTRATION AND THE NORTH CAROLINA SUPPLEMENT TO THE MUTCD. STANDARD PROCTOR TEST m ° ____ ____ ¢ o W _ p 12" O.C. EACH WAY W w _ LATCH ON m a 1' " 2'-0" x 2'-0" 1' 0" y a a z THIS LEAF N w O o D2.01 STOP SIGN DETAIL D2.02 TYPICAL LIGHT DUTY PAVEMENT CROSS SECTION D2.03 TYPICAL HEAVY DUTY CONCRETE CROSS SECTION p ° w dLLJ00 o W DROP ROD ON THIS LEAF a Q J NOT TO SCALE NOT TO SCALE o Cn � J NOT TO SCALE x J CO > J CO L oof �w D2.04 DUMPSTER PAD DETAIL LU 00 NOT TO SCALE PAVEMENT REPAIRS ON ROADS NOT TO BE RESURFACED (PIPE IS TO BE PLACED UNDER EXISTING PAVEMENT) EETIOF1 654.01 V A A �= ELEVATION PRESSURE TREATED 2 X 4 SIMPSON GALVANIZED FRAMING ANCHOR A34 ON UNDERSIDE OF 2x4's TREATED 2 X 8 WOOD CAP w/ GALVANIZED WOOD SCREWS AT 12" OC STAGGER COUNTERSINK HE SIMPSON GALVAN12 FRAMING ANCH A34 (T' TREATED 2 X 4, ATTACH w/ GALV FRAMING ANCHOR TO POST �IJBMBI���[�I9 GALVANIZED WOOD SCREWS, COUNTERSINK HEAD 4000 PSI CONCRETE 4" CRUSHED STONE P LA N SECTION A -A PRESSURE TREATED 2 X 4 PRESSURE TREATED (5) 1 X 6 VERTICAL BOARDS 45 MITER CORNERS OF 2 X 8 TOP CAP PRESSURE TREATED 4 X 4 POST GENERAL NOTES: 1. PRESERVATIVE PRESSURE TREAT LUMBER WITH WATER -BORNE PRESERVATIVES TO COMPLY WITH AWPA C2 AND C9, RESPECTIVELY, AND WITH REQUIREMENTS INDICATED BELOW. A. PRESSURE -TREAT ABOVE -GROUND ITEMS WITH WATER -BORNE PRESERVATIVES TO A MINIMUM RETENTION OF 0.25 PCF. B. PRESSURE -TREAT WOOD MEMBERS IN CONTACT WITH THE GROUND WITH WATER -BORNE PRESERVATIVES TO A MINIMUM RETENTION OF 0.40 PCF. 2. FASTENERS: OF SIZE AND TYPE INDICATED THAT COMPLY WITH THE FOLLOWING REQUIREMENTS. PROVIDE HOT -DIP ZINC -COATED FASTENERS PER ASTM A 153 OR AISI TYPE 304 STAINLESS STEEL FASTENERS. D2.05 DUMPSTER FENCE DETAIL NOT TO SCALE ° J d LLJ TRANSVERSE EXPANSION JOINT SIDEWALK SURFACE ° Q ° °Q 1 /2" 1/8" RAD.- JOINT FILLER TRANSVERSE EXPANSION JOINT PROPOSED SIDEWALK (CONC. 4000 P.S.I. MIN.) SEE PLAN GROOVE SURFACE VARIES f- 1/2"/FT. (SEE PLAN) 1/4"/FT. All LLJ COMPACTED EARTH Q° o °w a 0 a r n ° TYPICAL SECTION N. T. S. NOTES: 1. TRANSVERSE EXPANSION JOINTS TO BE A MAXIMUM OF 40 FEET. 2. ALL CONCRETE TO BE FINISHED WITH CURING COMPOUND. 3. A GROOVE JOINT 1" DEEP WITH 1/3" RADII SHALL BE REQUIRED IN THE CONCRETE SIDEWALK AT 5' INTERVALS. ONE 1/2" EXPANSION JOINT WILL BE REQUIRED AT 40' INTERVALS. A 1/2" EXPANSION JOINT WILL BE REQUIRED WHERE THE SIDEWALK JOINS ANY RIGID STRUCTURE. 4. 6%6"/ 1.4xl.4 W.W.F. REQUIRED IN ALL SIDEWALKS. SIDEWALK DETAIL D2.O8 NOT TO SCALE 2' NOTES: TRANSITION 1. TRANSVERSE NORMAL CURB EXPANSION JOINTS TO & GUTTER BE A MAXIMUM OF 30 FEET. 2. ALL CONCRETE BE FINISHED WITH CURING / COMPOUND. D2.10 CURB & GUTTER END TREATMENT NOT TO SCALE r-► A 6„ 1/2" RAD. � f SEE PAVING DETAIL 2" RAD. ASPHALT FG 6" MIN. COMPACTED ABC COMPACTED SUBGRADE COMPACTED CABC UNDER PAVING A 1/8" RAD. (TYP) 00 I N _ II JOINT SEALER I • I 9 JOINT FILLER 1 /2 1 TOOLED CONTRACTION JOINTS @ 10' O.C. SECTION A -A EXPANSION JOINTS © 30' O.C. AND ADJACENT TO ALL RIGID OBJECTS CONSTRUCTION NOTES: 1. CURB SHALL BE CONSTRUCTED WITH 4000 PSI CONCRETE 2. SURFACE SHALL BE GIVEN A LIGHT BROOM FINISH WITH THE BRUSH MARKS PARALLEL TO THE CURB. 3. SUB -GRADE SHALL BE COMPACTED TO 98% OF MODIFIED PROCTOR TEST 4. CABC SHALL BE COMPACTED TO 100% OF MODIFIED PROCTOR TEST D2.06 CONCRETE CURB & GUTTER (18") DETAIL NOT TO SCALE WALK WIDTH 6" SCORE PER PLAN /--- 3" RADIUS 4" WASHED STONE Nip COURSE 5 7 OR SURFACECOURSE COMPACTED SUBGRADE BASE COURSE 4" CONCRETE WITH 61IX611/ 1.4xl.4 W.W.F. 6 NOTES: PROVIDE SEALED 1/2" EXPANSION JOINTS AT 40'-0" O.C. AND AT RIGID STRUCTURES; 1" DEEP TOOLED JOINTS AT 8'-0" O.C. D2.09 TURNED DOWN SIDEWALK DETAIL NOT TO SCALE RAMP AREA (SEE DETAIL) HANDICAP SIGN (SEE DETAIL) PROPOSED STRIPING FOR PARKING TO BE 4" WIDE PROPOSED STRIPING FOR ACCESS ISLE TO BE 6" WIDE 8' 5' OR 8' 8' 21' or 24' NOTES: 1. ACCESS AISLE FOR CARS SHALL BE 5' AND FOR VANS 8' 2. ALL PAVEMENT MARKINGS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) PUBLISHED BY THE FEDERAL HIGHWAY ADMINISTRATION AND THE NORTH CAROLINA SUPPLEMENT TO THE MUTCD. D2.11 STRIPING AND HANDICAP PARKING DETAIL NOT TO SCALE 1 2%6" 12"x9" RESERVED 1 PARKING V/ A N ACCESSIBLE MAX PENALTY $250 60" MIN RESERVED PARKING VAN ACCESSIBLE MAX PENALTY $250 0.080" ALUMINUM HANDICAP PARKING SIGN. BOLT WITH 5/16" CADMIUM PLATED BOLT, NUTS AND WASHERS. GALVANIZED STEEL "U" POST WITH WEIGHT OF 2 LBS/FT, EXTEND INTO GROUND GROUND SURFACE 24" NOTES: 1. RESERVED PARKING SIGN SHALL INCLUDE A WHITE WHEELCHAIR SYMBOL ON A BLUE SQUARE. 2. SIGNS SHALL HAVE A GREEN LEGEND AND BORDER ON A WHITE BACKGROUND. 2. SIGNS IDENTIFYING VAN PARKING SPACES SHALL CONTAIN THE DESIGNATION "VAN ACCESSIBLE". 3. ALL SIGNS AND STRIPING SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND THE NORTH CAROLINA SUPPLEMENT TO THE MUTCD. ACCESSIBLE PARKING SPACE SIGN D2.12 �9 NOTE: ISOMETRIC VIEW USE NEENAH FOUNDRY COMPANY R-4984 DETECTABLE WARNING PLATE OR EQUAL. MUST COMPLY WITH ADAAG (AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES) AND ARCHITECTURAL BARRIER ACT 1968 GUIDELINES. 1-15/16" 82 -04 A W+A+9" X B 0.0' 5.8' 5.8' 5. 0'* 0.0' 6. 8' 6.8' 6. 0'* 0.0' 7.8' 7.3' 6.5'** 0. 0' 8.8' 7.3' 6.5'** 2. 0' 7.8' 7.8' 5. 0' 2.5' 8.3' 8.1' 4.8' 3.0' 8.8' 8.3' 4.4' 3.5' 9.3' 8.4' 4. 1' 4. 0' 9.8, S.6' 3. 8' 4.5' 10.3' 8.7' 3.4' 5.0' 10.8' 8.9' 3. 1' LINE OF BUILDING, PLANTED AREA FENCE, ETC. TRUNCATED DOMES MEETING ADA GUIDELINES SHALL BE INSTALLED FOR THE LAST 2 FEET OF THE RAMP AT ITS INTERFACE WITH THE STREET, AT THE FULL WIDTH OF THE RAMP (TO BE INSTALLED ON ALL CROSSWALKS) < O 0 0000 0000 e000000000000 100, 4' MIN 16' MIN CURB SLOPES DOWN AT SAME RATE AS SIDE FLARES. MAX B = X-(A+9") B = DISTANCE FROM FRONT EDGE OF SIDEWALK TO BACK POINT OF 12:1 (8.33%) SLOPE. * BACK OF SIDEWALK DROP REQUIRED FOR ALL SIDEWALK SLOPES. NOTE: 1.SINGLE RAMPS MAY ONLY BE USED WHERE SIDEWALK WILL NOT BE INSTALLED ALONG THE SIDE STREET OR DRIVEWAY. 2. RAMPS INSTALLED ALONG N.C.D.O.T. ROADWAYS MUST MEET N.C.D.O.T. STANDARD 848.05. CAST IRON DETECTABLE WARNING PATE D2.14 STANDARD WHEELCHAIR RAMP NOT TO SCALE 4.7.2.1 IF DIMENSION "A" IS 48" OR GREATER AND PEDESTRIANS MAY WALK ACROSS THE CURB CUT, THEN SIDE FLARES SHALL HAVE A 1:10 MAXIMUM SLOPE. ACCESSIBLE ROUTE CROSSES OVER CURB CUT LINE OF BUILDING, PLANTED AREA AND SIDE FLARES. FENCE, ETC. w J z g 0 _ m tioAF ��e� 4' MIN 16' MIN CURB SLOPES DOWN AT SAME RATE AS SIDE FLARES. D2.13 HANDICAPPED RAMP DETAIL NOT TO SCALE 4.7.2.2 IF DIMENSION "B" IS LESS THAN 48" AND PEDESTRIANS MUST WALK ACROSS THE CURB CUT, THEN SIDE FLARES SHALL HAVE A 1:12 MAXIMUM SLOPE. SIDEWALK �5' STD) 5„ A B DROP CURB UTILITY STRIP (STD. 2'6" CURB 0.02 (MIN.) 0.01 (MIN.) & GUTTER SHOWN) 0.08 (MAX) 0.04 (MAX) 0.04 (NORM) 0.02 (NORM) R=3" 12:1 MAX RAMP g„ DETECTABLE WARNING XPLATE (SEE DETAIL) SECTION B-B. 4'-0" 6'-0" MIN 6'-0' SIDEWALK CURB DROP CURB ELEVATION TRANSITION CURB TRANSITION TOP OF CURB VARIABLE SLOPE NOT TO EXCEED 12:1 (8.33%) SECTION A -A. DETECTABLE WARNING LATE TO BE INSTALLEI RE SIDEWALK INTERSE ROAD (SEE DETAIL) PLAN VIEW STREET GUTTER ION JOINT N S9.513 ASPHALT N I19.013 ASPHALT BINDER CABC STONE COMPACTED TO 100% OF MAXIMUM LABORATORY DRY DENSITY (ASTM D 1557 OR AASHTO T 180) MINIMUM 24" COMPACTED SUBGRADE TO MINIMUM 98% OF THE MAXIMUM DRY DENSITY USING THE MODIFIED PROCTOR TEST D2.15 TYPICAL HEAVY DUTY PAVEMENT CROSS SECTION NOT TO SCALE 6„ 4'-0" 6„ TOOLED EDGE (TYP) FINISH GRADE FINISH GRADE 3" RADIUS (TYP) 11=111-- 4000 PSI II �11=11 1111�IIll CONCRETE l AID 6" 111 • 11-, 1�1=11 III- 6' 6" MIN. COMPACTED ABC COMPACTED SUBGRADE CONCRETE FLUME DETAIL D2.16 NOT TO SCALE SITE DETAILS E 0 U �i o a0i o O) U rn a�i �Q L6 0 00 V V � 0, L u•�M } a N ° _ .0 0 N O Q) Qr O � r- UNhe E 0 U N -a LO LOLO-a v N 0 �00M U N 0 U o 00 N I--�---�--�i -�I a 'O U 3Nz W X _ C m O > Q N UaQ 4 U. o�WW G� b��� a z x m o as N w w a r o LL J�a Z, a Q a U) cc,ry 2 00 a w w m z This drawing is the property of Cope Associates, Inc and is not to be reproduced without prior written authorization. This drawing is intended to be used only for the project and site specifically identified. All design information are the copyright of Cope Associates Inc. @ 2020 REVISIONS NO. DATE DESCRIPTION 0 11 /04/22 ISSUED FOR BID 1 12/09/22 ADDENDUM 3 DATE: 12/2/2022 DRAWN BY: JCP =Qa� -vain ar J= U �°W- %y°off 0� DWG NO. C921 PROJECT NO. 12208 FULL SHEET SIZE: 36"X48" 8' MAX / Q / CLASS 'ACLASS 'A' STONE 8 IN. MIN. DEPTH N OTE: 1. TOP, FRAME, AND GRATE SHALL BE PLACED ON TOP OF BRICKS NCDOT #5 OR #57 WASHED STONE BRICKS TO ALLOW DE -WATERING THROUGH VOID�f Z vy x U ►a NOTES vov=x 1. PROVIDE TURNING RADIUS SUFFICIENT TO ACCOMMODATE LARGE F� 0 TRUCKS. Fx�xw 2. LOCATE ENTRANCES TO PROVIDE FOR UTILIZATION U BY ALL CONSTRUCTION VEHICLES. o v v 3. MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT x y TRACKING OR DIRECT FLOW OF MUD ONTO STREETS. a o PERIODIC TOPDRESSING WITH STONE WILL BE NECESSARY. wo 4. ANY MATERIAL TRACKED ONTO THE ROADWAY MUST BE CLEANED UP IMMEDIATELY. S. LOCATE GRAVEL CONSTRUCTION ENTRANCE AT ALL POINTS OF INGRESS AND EGRESS UNTIL SITE IS STABILIZED. PROVIDE FREQUENT CHECKS OF THE DEVICE AND TIMELY MAINTENANCE. B. NUMBER AND LOCATION OF CONSTRUCTION ENTRANCES TO W BE DETERMINED BY THE ENGINEER. v 7. USE CLASS 'A' STONE OR OTHER COARSE AGGREGATE APPROVED = cr BY THE ENGINEER. C3 8. INSTALL CONSTRUCTION ENTRANCES IN A WAY TO PREVENT VEHICLES LL FROM BYPASSING CONSTRUCTION ENTRANCE LEAVING PROJECT SITE. z `Z Z �o M o cc . 0 x GC N M C � cc 9 NOTE: PLACE GEOTEXTILE FOR DRAINAGE BENEATH STONE 4' MAX �)a000(g °0000 b o 3'- 4' EET 1 Of 1 607.01 2" STEEL ANGLE SET 18" IN GROUND 2:1 SLOPE, GRAVEL FILTER o 19 GAUGE HARDWARE CLOTH i OPENINGS 4" SPACES 3RICKS TO ALLOW ING THROUGH VOIDS CONSTRUCTION NOTES: 1. LAY BRICK ALONG TOP OF CATCH BASIN WITH 4" SPACES BETWEEN BRICKS. SET FRAME AND GRATE ON BRICKS. 2. CAREFULLY FIT HARDWARE WIRE OR COMPARABLE WIRE MESH WITH 1/2-INCH OPENINGS AROUND CATCH BASIN TO HOLD GRAVEL IN PLACE. 3. USE CLEAN GRAVEL, 3/4- TO 1/2-INCH IN DIAMETER, PLACED 2 INCHES BELOW THE TOP OF THE GRATE ON A 2:1 SLOPE OR FLATTER AND SMOOTH IT TO AN EVEN GRADE. DOT #57 WASHED STONE IS RECOMMENDED. 4. SEDIMENT SHALL BE REMOVED AND TRAP RESTORED TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO 1/2 THE DESIGN DEPTH OF THE TRAP. 5. REMOVED SEDIMENT SHALL BE DEPOSITED IN A SUITABLE AREA AND IN SUCH A MANNER THAT IT WILL NOT ERODE. 6. THE STRUCTURE SHALL BE INSPECTED BY THE FINANCIALLY RESPONSIBLE PARTY OR HIS AGENT AFTER EACH STORM EVENT AND REPAIRS MADE AS NECESSARY. 7. CONSTRUCTION OPERATIONS SHALL BE CARRIED OUT IN SUCH A MANNER THAT EROSION AND WATER POLLUTION ARE MINIMIZED. 8. THE SEDIMENT TRAP SHALL BE REMOVED AND THE AREA STABILIZED WHEN THE DRAINAGE BASIN HAS BEEN PROPERLY STABILIZED. 9. ON LARGER DRAINAGE AREAS RIP RAP MAY BE REQUIRED UNDER THE WASHED STONE STONE INLET PROTECTION D3.03 NOT TO SCALE a ro PIPE OUTLET TO FLAT AREA NO WELL-DEFINED CHANNEL PIPE OUTLET TO WELL-DEFINED CHANNEL PLAN La a La o FILTER BLANKET FILTER BLANKET SECTION AA SECTION AA NOTES: 1. Lo IS THE LENGTH OF THE RIP RAP APRON. 2. d = 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT LESS THAN 6" (MINIMUM IS 24" DEEP IF STONE IS CLASS II) 3. IN A WELL-DEFINED CHANNEL, EXTEND THE APRON UP THE CHANNEL BANKS TO AN ELEVATION OF 6" ABOVE THE MAXIMUM TAILWATER DEPTH OR TO THE TOP OF THE BANK, WHICHEVER IS LESS. 4. A FILTER BLANKET OR FILTER FABRIC SHOULD BE INSTALLED BETWEEN THE RIP RAP AND SOIL FOUNDATION. 5. COMPACT ANY REQUIRED FILL TO DENSITY OF SURROUNDING UNDISTURBED MATERIAL. 6. RIP RAP MAY BE FIELDSTONE OR ROUGH QUARRY STONE AND SHALL BE HARD. ANGULAR AND WELL -GRADED. 7. CONSTRUCT APRON AT ZERO GRADE. TOP OF RIP RAP SHALL BE LEVEL WITH THE RECEIVING CHANNEL OR SLIGHTLY LOWER. 8. ALIGN APRON WITH RECEIVING CHANNEL OR STREAM. ASSURE APRON IS STRAIGHT THROUGHOUT ITS LENGTH. 9. END WIDTH OF APRON TO BE EQUAL TO WIDTH OF RECEIVING CHANNEL. D3.09 RIP -RAP APRON NOT TO SCALE MIN. 10 GA. LINE WIRES (TYP) FRONT VIEW CONSTRUCTION NOTES: MATERIALS NOTES: "EL POST ASTIC OR RE TIES (TYP) STEEL POST WOVEN WIRE FABRIC SILT FENCE FILTER FABRIC 0 5'-0" I J. 12-1 /2 GA. N -ERMEDIATE o RES (TYP) n b III ; FILL SLOPE EX. GRADE EX. GRADE ANCHOR 12" LONG SKIRT IN TRENCH 8" DEEP AND 4" WIDE* 1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD 1. USE A SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY STRENGTH OR EXTRA STRENGTH SYNTHETIC FILTER WEIGHT OF POLYOLEFINS OR POLYESTER, WHICH IS FABRICS. CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFORMING TO THE REQUIREMENTS IN ASTM D 6461, 2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES WHICH IS SHOWN IN PART IN TABLE 6.62b OF THE NOT EXCEED 24" ABOVE THE GROUND SURFACE. (HIGHER NCDENR EROSION AND SEDIMENT CONTROL PLANNING AND FENCES MAY IMPOUND VOLUMES OF WATER SUFFICIENT TO DESIGN MANUAL. CAUSE FAILURE OF THE STRUCTURE.) 2• SYNTHETIC FILTER FABRIC SHOULD CONTAIN ULTRAVIOLET 3. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS RAY INHIBITORS AND STABILIZERS TO PROVIDE A MINIMUM ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID OF 6 MONTHS OF EXPECTED UUUABLE CONSTRUCTION LIFE JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY AT A TEMPERATURE RANGE OF 0 TO 120`F. FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4' MIN. OVERLAP TO THE NEXT POST. 3. ENSURE THAT POSTS FOR SEDIMENT FENCES ARE 1.33 LB/LINEAR FT STEEL WITH A MINIMUM LENGTH OF 5 FEET. 4. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MAKE SURE THAT STEEL POSTS HAVE PROJECTIONS TO MESH FASTENED SECURELY TO THE UPSLOPE SIDE OF THE FACILITATE FASTENING THE FABRIC. POSTS. EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE 4. FOR REINFORCEMENT OF STANDARD STRENGTH FILTER REINFORCEMENT, THEN THE FABRIC ON THE UPSLOPE SIDE FABRIC, USE WIRE FENCE WITH A MINIMUM 14 GAUGE AND OF THE FENCE POST. WIRE OR PLASTIC TIES SHOULD A MAXIMUM MESH SPACING OF 6 INCHES. HAVE A MIN. 50 lb TENSILE STRENGTH. NOTES: 5. EXCAVATE A TRENCH APPROXIMATELY 4" WIDE AND 8" DEEP ALONG THE PROPOSED LINE OF POSTS AND USE SILT FENCE ONLY WHEN DRAINAGE AREA DOES NOT UPSLOPE FROM THE BARRIER. EXCEED 1 /4 ACRE AND NEVER IN AREAS OF CONCENTRATED FLOW 6. PLACE 12" OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. * FOR REPAIR OF SILT FENCE FAILURES, USE No. 57 WASHED STONE. AS AN ANCHOR WHEN SILT FENCE IS PROTECTING 7. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE CATCH BASIN. FILTER FABRIC AND COMPACT. THOROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE. 8. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES. SILT FENCE D3.O2 NOT TO SCALE NISHED GRADE Ln j\/j C350 DITCH LINER NOTE: 2 DITCH SLOPE TO BE AT A 2% MIN SLOPE PERMANENT DRAINAGE DITCH'A' FROM INLET TO OUTLET D3.04 NOT TO SCALE lnlnvr=la nl rr=o r= noolr D3.06 CONCENTRATED FLOW OUTLETS - SILT FENCE NOT TO SCALE CHANNEL INSTALLATION 12" N. 4" -STEEL POST WIRE FENCING OQ� 6" � II- ���'� II=III- III�I C' -STEEL POST WIRE FENCING -CLASS I RIP RAP #5 WASHED STONE 4"-6" (1Ocm-15cm) 1. PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. NOTE: WHEN USING CELL-0-SEED DO NOT SEED PREPARED AREA. CELL-O-SEED MUST BE INSTALLED WITH PAPER SIDE DOWN. 2. BEGIN AT THE TOP OF THE CHANNEL BY ANCHORING THE BLANKET IN A 6" (15cm) DEEP X 6" (15cm) WIDE TRENCH WITH APPROXIMATELY 12" (30cm) OF BLANKET EXTENDED BEYOND THE UP -SLOPE PORTION OF THE TRENCH. ANCHOR THE BLANKET WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30cm) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" (30cm) PORTION OF BLANKET BACK OVER SEED AND COMPACTED SOIL. SECURE BLANKET OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" (30cm) APART ACROSS THE WIDTH OF THE BLANKET. 3. ROLL CENTER BLANKET IN DIRECTION OF WATER FLOW IN BOTTOM OF CHANNEL. BLANKETS WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL BLANKETS MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING OPTIONAL DOT SYSTEM , STAPLES/STAKES SHOULD BE PLACED THROUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN. 4. PLACE CONSECUTIVE BLANKETS END OVER END (SHINGLE STYLE) WITH A 4"-6" (10cm-15cm) OVERLAP. USE A DOUBLE ROW OF STAPLES STAGGERED 4" (10cm) APART AND 4" (10cm) ON CENTER TO SECURE BLANKETS. 5. FULL LENGTH EDGE OF BLANKETS AT TOP OF SIDE SLOPES MUST BE ANCHORED WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30cm) APART IN A 6" (15cm) DEEP X 6" (15cm) WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. 6. ADJACENT BLANKETS MUST BE OVERLAPPED APPROXIMATELY 2"-5" (5cm-12.5cm) (DEPENDING ON BLANKET TYPE) AND STAPLED. TO ENSURE PROPER SEAM ALIGNMENT, PLACE THE EDGE OF THE OVERLAPPING BLANKET (BLANKET BEING INSTALLED ON TOP) EVEN WITH THE COLORED SEAM STITCH ON THE BLANKET BEING OVERLAPPED 7. IN HIGH FLOW CHANNEL APPLICATIONS, A STAPLE CHECK SLOT IS RECOMMENDED AT 30 TO 40 FOOT (9m-12m) INTERVALS. USE A DOUBLE ROW OF STAPLES STAGGERED 4" (10cm) APART AND 4" (10cm) ON CENTER OVER ENTIRE WIDTH OF THE CHANNEL. 8. THE TERMINAL END OF THE BLANKETS MUST BE ANCHORED WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30cm) APART IN A 6" (15cm) DEEP X 6" (15cm) WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. NOTE: CRITICAL POINTS * HORIZONTAL STAPLE SPACING SHOULD BE ALTERED IF A. OVERLAPS AND SEAMS NECESSARY TO ALLOW STAPLES TO SECURE THE CRITICAL B. PROJECTED WATER LINE POINTS ALONG THE CHANNEL SURFACE. C. CHANNEL BOTTOM/SIDE SLOPE VERTICES ** IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR A A STAKE LENGTHS GREATER THAN 6" (15 cm) MAY BE B B NECESSARY TO PROPERLY ANCHOR THE BLANKETS. C C 14649 HIGHWAY 41 NORTH, EVANSVILLE, INDIANA 47725 USA 1-800-772-2040 CANADA 1-800-448-2040 www n°gre n.c°m -111-1�1= 4 tNow COMPACTED SOIL 1�l,ll�l_ �2' MIN EXISTING -Ill-II_Ill- 11 GROUND-111-11�11�_1 -111 11=111 - _ 18" MIN 1' DITCH DEPTH INIll- ORIGINAL GROUND-IIIIII I-II,I�IIIIIIIT=II�T�I�IIll=1 1= -1 CONSTRUCTION SPECIFICATIONS:-III-III- 6' TYP 1. REMOVE AND PROPERLY DISPOSE OF ALL TREES, BRUSH, STUMPS, AND OTHER OBJECTIONABLE MATERIAL. 2. ENSURE THAT THE MINIMUM CONSTRUCTED CROSS SECTION MEETS ALL DESIGN REQUIREMENTS. 3. ENSURE THAT THE TOP OF THE DIKE IS NOT LOWER AT ANY POINT THAN THE DESIGN ELEVATION PLUS THE SPECIFIED SETTLEMENT. 4. PROVIDE SUFFICIENT ROOM AROUND DIVERSIONS TO PERMIT MACHINE RE -GRADING AND CLEAN OUT. 5. CONSTRUCT ALL TEMPORARY DIVERSION DITCHES WITH A MINIMUM 2% SLOPE. 5. VEGETATE THE RIDGE IMMEDIATELY AFTER CONSTRUCTION, UNLESS IT WILL REMAIN IN PLACE LESS THAN 30 WORKING DAYS. TEMPORARY DIVERSION DITCH D3.05 NOT TO SCALE Dewatering Device or dirt/sediment bag) Discharge Hose Dewatering Pump P (as needed) Sump -hole } Or Pool A A 12" Min Depth Flow Flow 2' Min Diameter Work Area Sandbag/Stone Barrier Intake Hose P Discharge Hose Diversion Pump Discharge Pump Into Velocity Work Area Dissipater Length Not To Exceed That Which Can Be Completed In One Day Sheeting Work Area (2 Foot Minimum) Cross Section Of Sandbag/Stone Diversion SECTION A -A PUMP AROUND / DEWATERING D3.07 PLAN VIEW DETAIL NOT TO SCALE Base Flow + 1 Foot TOP VIEW = SEWN IN NECK DIRTBAG 3 OPENING ACCOMO➢ATES UP TO 4' ➢ISCHARGE LENGTH HOSE NOTES: 1) DIRTBAG TO BE PLACED ON AGGREGATE OR STRAW 2) SEAMS MUST BE HIGH STRENGTH DOUBLE STITCHED 'J" SEAMS 3) SEAM MUST BE TESTED UNDER ASTM D-4884, ACF TEST RESULTS AVAILABLE UPON REQUEST 4) THIS WORK SHALL CONSIST OF FURNISHING, PLACING AND REMOVAL OF ASSOCIATED DEVICE 4) CONTRACTOR IS REQUIRED TO USE A DIRTBAG DB-55 OR APPROVED EQUIVELENT CROSS SECTION T DB55 FABRIC PROPERTIES PROPERTY TEST METHOD MARV TENSILE STRENGTH ASTM D-4622 205 LBS ELONGATION ASTM D-4632 50% CBR PUNCTURE ASTM D-6241 525 LBS UV RESISTANCE ASTM D-4355 70% AOS ASTM D-4751 80 US SIEVE PERMITTIVITY ASTM D-4491 1.4 SEC-1 FLOW RATE ASTM D-4491 90 GPM/SF CORPORATE OFFICE 2831 CARDWELL ROAD ACF DB55 DIRTBAG RICHMOND, VA 23234 ]��, ]M= PH 930-448-3636 FOR ADDITIONAL INFORMATION PLEASE CONTACT ACF ENVIMNNENTAL •-n 4-T r u+•- WVVACFENV[RONTENTAL.mM PH: 8110-4413-3636 / WWWACFENVIRGgWNFAL.COM DEWATERING BAG D3.O8 NOT TO SCALE EROSION CONTROL NOTES GENERAL: ALL EROSION CONTROL MEASURES ARE TO BE PERFORMED IN STRICT ACCORDANCE WITH REQUIREMENTS OF NCDEQ. THE FOLLOWING CONSTRUCTION SEQUENCE SHALL BE COMPLIED WITH FOR ALL WORK. ALL BORROW AND/OR WASTE MUST COME FROM OR GO TO A PERMITTED SITE OR FACILITY. CONTRACTOR TO PROVIDE NCDEQ INSPECTOR WITH PERMIT NUMBER OF BORROW/WASTE SITE BEFORE TRANSPORTING MATERIALS. 1. OBTAIN LAND DISTURBING PERMIT. 2. INSTALL ALL EROSION CONTROL MEASURES AS REQUIRED BY NCDEQ. 3. OBTAIN CERTIFICATE OF COMPLIANCE THROUGH ON -SITE INSPECTION BY A REPRESENTATIVE OF NCDEQ. 4. PROCEED WITH GRADING, CLEARING AND GRUBBING. 5. ALL STOCKPILES TO BE SURROUNDED BY SILT FENCE ON LOW SIDE WITH ACCESS FROM THE HIGHER SIDE. STOCKPILES TO BE LOCATED MINIMUM OF 50 FEET FROM ANY STORMWATER INLET, STREAM BUFFER, OR WETLAND. 6. SEED AND MULCH DENUDED AREA AS SOON AS POSSIBLE BUT NO LATER THAN 15 DAYS AFTER FINISHED GRADE ARE ESTABLISHED. TEMPORARY SEED AND SOIL AMENDMENTS SHALL BE PLACED ON A PREPARED (ROUGHENED, TRACKED, OR RAKED) SEEDBED AT A RATE DETERMINED BY SOIL TESTING, OR AS STATED BELOW (RATES PER ACRE): TEMPORARY SEEDING OF BUILDABLE AREAS MULCH 300 LBS OATS 100 LBS FOR LATE WINTER/EARLY SPRING SEEDING ADD TO THE ABOVE: RYE GRAIN 120 LBS ANNUAL LESPEDEZA 50 LBS (OMIT IF COVER IS NOT TO EXTEND BEYOND JUNE) FOR SUMMER SEEDING ADD: GERMAN MILLET 40 LBS FOR FALL ADD: RYE GRAIN 120 LBS FOR ALL SLOPES 2:1 OR STEEPER ADD TO THE ABOVE: PANICUM VIRGATUM 40 LBS IF HYDROSEEDING IS USED, WOOD CELLULOSE MAY BE SUBSTITUTED FOR STRAW MULCH AT THE RATE OF 1,000 LBS PER ACRE. 7. USE NORTH CAROLINA NATIVE RIPARIAN SEED LIST FOR ANY SEEDING/PLANTINGS WITHIN ANY RIPARIAN/TROUT BUFFER. NO FERTILIZERS OR ASPHALT TACKIFIER WITHIN RIPARIAN/TROUT BUFFERS. 8. ALL WORK WITHIN STREAM/WETLAND BUFFERS MUST BE STABILIZED AT THE END OF EACH DAY. 8. MAINTAIN SOIL EROSION CONTROL MEASURES UNTIL PERMANENT GROUND COVER IS ESTABLISHED. 9. REMOVE SOIL EROSION CONTROL MEASURES AND STABILIZE THESE AREAS. 10. REQUEST FINAL APPROVAL BY NCDEQ. CONSTRUCTION SEQUENCE 1. NOTIFY NCDEQ INSPECTOR 48 HOURS BEFORE CONSTRUCTION BEGINS. 2. INSTALL SITE CONSTRUCTION ENTRANCE/STONE STAGING/MOBILIZATION AREA. 2. INSTALL SILT FENCE BELOW SKIMMER BASIN 'A.' INSTALL SKIMMER BASIN 'A', REMAINING SILT FENCES, TEMPORARY DIVERSION DITCHES, PERMANENT DITCHES, PROPOSED STORM BYPASS 'C', AND CULVERTS 'Z1' AND 'Z2'. WORK WITHIN DRAINAGE BASINS WILL REQUIRE INSTALLATION OF ALL SEDIMENT CONTROL COMPONENTS. ESTABLISH CONSTRUCTION ROUTES AND INSTALL RAIN GAUGE ON -SITE. STABILIZE SEDIMENT BASIN IMMEDIATELY UPON COMPLETION. 3. STREAM CONSTRUCTION ACTIVITIES MUST BE COMPLETED IN ACCORDANCE WITH DETAIL D3.07 AND D3.08. DETAIL MUST BE CONSTRUCTED FROM UPSTREAM TO DOWNSTREAM DIRECTION. NO WORK CAN COINCIDE WITH RAINFALL. NOTHING SHALL BE PLACED IN THE STREAM UNTIL ALL MATERIALS ARE ON SITE AND THE INSTALLATION IS READY TO PROCEED. CONTRACTOR MUST MONITOR TURBIDITY BELOW THE PROJECT AREA. IF THE TURBIDITY EXCEEDS 10 NTU WHEN MEASURED 20 FEET DOWNSTREAM OF THE WORK AREA, THE PROJECT MUST BE HALTED, THE TURBIDITY MUST BE ALLOWED TO SETTLE, AND WORK CANNOT RESUME UNTIL THE 10 NTU STANDARD IS MET. ALL COMPONENTS OF THE WORK MUST BE REMOVED IMMEDIATELY UPON COMPLETION OF THE INSTALLATION. ALL WORK WITHIN STREAM/WETLAND BUFFERS MUST BE STABILIZED AT THE END OF EACH DAY. ANY STABILIZATION MATTING, STAKING, ETC. WITHIN THE STREAM MUST BE COMPLETELY BIODEGRADABLE (NO PLASTIC REINFORCEMENT). 4. PROCEED WITH CLEARING AND GRUBBING. NO MAJOR GRADING ACTIVITIES SHOULD BE PREDICTED PERIODS OF WET WEATHER, I.E. HURRICANES, ETC. 5. PROCEED WITH GRADING AND EROSION CONTROL MAINTENANCE. NPDES LOG TO BE KEPT CURRENT AND ACCESSIBLE AT PROJECT SITE AT ALL TIMES. 6. CONSTRUCT PROPOSED STORM DRAINAGE SYSTEM WITH INLET AND OUTLET PROTECTION. MAINTAIN EROSION CONTROL DEVICES. INSTALL INLET PROTECTION BY THE END OF THE WORKDAY FOR ALL CONSTRUCTED STORMWATER INLETS. 7. APPLY TEMPORARY AND PERMANENT SEEDING, RIP RAP AND STABILIZATION MEASURES. 8. PROCEED WITH REMAINING SITEWORK. SITE MUST BE "STORM READY" BEFORE ANY PROLONGED BREAKS IN CONSTRUCTION INCLUDING WEEKENDS. 9. ONCE THE UPSTREAM SITE IS STABILIZED AND UPON ENGINEER & NCDEQ APPROVAL AND CLEANING OF ALL UPSTREAM PIPING, CONVERT SKIMMER BASIN 'A' TO PROPOSED WET POND 'A'. COMPLETE GRADING, SITEWORK & STABILIZATION WITH PERMANENT SEEDING, MULCH, AND LANDSCAPE. 10. MAINTENANCE INSPECTIONS SHALL BE PERFORMED WEEKLY AND AFTER EACH RAINFALL. ALL REPAIRS NECESSARY SHOULD BE MADE IMMEDIATELY AND IN STRICT ACCORDANCE WITH MITCHELL COUNTY STANDARDS AND NPDES PERMIT. 11. NOTIFY NCDEQ INSPECTOR WHEN PROJECT IS READY FOR A CLOSE OUT INSPECTION. SUBMIT NOTICE OF TERMINATION WHEN THE CLOSE OUT INSPECTION IS RECEIVED. GROUND STABILIZATION SITE AREA DESCRIPTION STABILIZATION STABILIZATION TIME TIME FRAME FRAME EXCEPTIONS PERIMETER DIKES, SWALES, 7 DAYS NONE DITCHES, AND SLOPES HIGH QUALITY WATER (HOW) ZONES 7 DAYS NONE SLOPES GREATER THAN 3:1 7 DAYS IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED SLOPES 3:1 OR FLATTER 14 DAYS 7-DAYS FOR SLOPES GREATER THAT 50' IN LENGTH ALL OTHER AREAS WITH 14 DAYS NONE (EXCEPT FOR SLOPES FLATTER THAN 4:1 PERIMETERS AND HOW ZONES) *EXTENSIONS OF TIME MAY BE APPROVED BY THE PERMITTING AUTHORITY BASED ON WEATHER OR OTHER SITE -SPECIFIC CONDITIONS THAT MAKE COMPLIANCE IMPRACTICABLE. (SECTION II.B(2)(B)) GENERAL NOTES FOR EROSION CONTROL 1. ALL GRADING AND SOIL EROSION CONTROL MEASURES ON THIS SITE MUST BE AUTHORIZED BY PERMITS ISSUED BY MITCHELL COUNTY. ALL SITEWORK SHALL BE IN ACCORDANCE WITH ALL LOCAL, STATE, AND NATIONAL REGULATORY STANDARDS AND ALL REQUIREMENTS IN THE PROJECT TECHNICAL SPECIFICATIONS. 2. CONTRACTOR TO VERIFY WITH ENGINEER THAT THE REQUIRED GRADING, EROSION CONTROL, LAND DISTURBANCE, AND ASSOCIATED NON -GRADING PERMITS HAVE BEEN OBTAINED PRIOR TO BEGINNING CONSTRUCTION. 3. ALL CONSTRUCTION SHALL BE UNDER THE INSPECTION OF THE ENGINEER, THE OWNER, AND MITCHELL COUNTY. THE CONTRACTOR SHALL NOTIFY THE ENGINEER 72 HOURS PRIOR TO BEGINNING WORK. ANY WORK COVERED PRIOR TO ENGINEER'S INSPECTION IS SUBJECT TO UNCOVERING AND BACKFILLING AT THE CONTRACTOR'S EXPENSE. 4. ALL WORK MUST BE PERFORMED BY A NORTH CAROLINA LICENSED CONTRACTOR. 5. CONTRACTOR IS RESPONSIBLE FOR LOCATING AND VERIFYING THE EXACT LOCATION AND ELEVATION FOR ALL UTILITIES PRIOR TO CONSTRUCTION; AND TO NOTIFY ENGINEER OF ANY CONFLICTS OR DISCREPANCIES. THE LOCATION OF SOME UTILITIES SHOWN ON THE PLANS HAVE BEEN APPROXIMATED. ALL BURIED UTILITIES HAVE NOT BEEN SHOWN ON THE PLANS AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THEIR LOCATION PRIOR TO CONSTRUCTION. 6. PROTECT EXISTING SITE FEATURES SHOWN TO REMAIN AND NEWLY COMPLETED WORK DURING CONSTRUCTION. ANY DAMAGE INCURRED DURING OR RESULTING FROM CONSTRUCTION ACTIVITY IS THE RESPONSIBILITY OF THE CONTRACTOR AND IS TO BE REPAIRED IN ACCORDANCE WITH APPLICABLE STANDARDS OF APPROPRIATE AGENCIES, AS WELL AS THE PROJECT PLANS AND SPECIFICATIONS, AT THE CONTRACTOR'S EXPENSE. 7. THE CONTRACTOR IS TO NOTIFY ALL UTILITY COMPANIES AT LEAST 72 HOURS BEFORE CONSTRUCTION ACTIVITY IS TO BEGIN. THE CONTRACTOR SHALL NOTIFY NC ONE CALL AT 811, 48 HOURS BEFORE CONSTRUCTION BEGINS. NOTIFY THE ENGINEER AT LEAST 72 HOURS BEFORE STARTING CONSTRUCTION ACTIVITIES. 8. EROSION CONTROL IS A FIELD PERFORMANCE BASED ACTIVITY; AND ADDITIONAL SILT FENCES, TEMPORARY SEDIMENT BASINS, AND ALL OTHER MEASURES MAY NEED TO BE ADDED IN ADDITION TO THE APPROVED PLAN AS NECESSARY. MEASURES SHOWN CAN AND SHOULD BE ADJUSTED TO ASSURE MAXIMUM PROTECTION ON SITE. CONTRACTOR SHALL ADD ADDITIONAL MEASURES AS NEEDED IN ENVIRONMENTALLY SENSITIVE AREAS. 9. CONTRACTOR IS RESPONSIBLE FOR INSTALLING, MAINTAINING, AND REMOVING ALL NECESSARY EROSION AND SEDIMENTATION CONTROL MEASURES. 10. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ADJUSTMENT OF ALL UTILITY SURFACE ACCESSES WHETHER THE CONTRACTOR PERFORMS THE WORK OR A UTILITY COMPANY PERFORMS THE WORK. 11. ALL AREAS WHERE THERE IS EXPOSED DIRT SHALL BE SEEDED, FERTILIZED AND MULCHED ACCORDING TO THE SPECIFICATIONS NOTES IN THE PLANS. SITE STABILIZATION IS A PERFORMANCE BASED REQUIREMENT, AND THE SITE WILL NOT BE ACCEPTED UNTIL PERMANENT VEGETATION IS ESTABLISHED TO THE SATISFACTION OF THE ENGINEER. 12. CONTRACTOR RESPONSIBLE FOR KEEPING ACCURATE LOG OF SITE CONDITIONS IN ACCORDANCE WITH NPDES PERMIT. MAINTENANCE INSPECTIONS SHALL BE PERFORMED WEEKLY AND AFTER EACH RAINFALL. ALL REPAIRS NECESSARY SHOULD BE MADE IMMEDIATELY AND IN STRICT ACCORDANCE WITH MITCHELL COUNTY STANDARDS AND NPDES PERMIT. CONTRACTOR SHALL SUPPLY THE ENGINEER WITH RECORD OF DEVIATIONS FROM PLANS FOR PREPARATION OF FINAL RECORD DRAWINGS. 13. ALL SLOPES GREATER THAN 2:1 SLOPE AND OVER 5' IN HEIGHT SHALL BE CERTIFIED BY A LICENSED PROFESSIONAL AS REQUIRED BY MITCHELL COUNTY. 14. CONTRACTOR IS REQUIRED TO OBTAIN AND PROVIDE A COPY OF THE EROSION CONTROL PERMIT FOR ANY OFFSITE BORROW/ SPOIL AREA. CONTRACTOR MUST PROVIDE COPY OF PERMIT TO MITCHELL COUNTY INSPECTOR PRIOR TO CONSTRUCTION. 15. IF BORROWED OR WASTE FILL MATERIAL IS GENERATED, AN APPROVED GRADING PERMIT MUST BE SECURED FOR THE BORROW OR WASTE MATERIAL SITE PRIOR TO INITIATION OF ANY LAND DISTURBING ACTIVITY 16. ALL FILL SLOPES SHALL BE COMPACTED FULL DEPTH TO NOT LESS THAN 95% MAXIMUM DENSITY (STANDARD PROCTOR), SHALL BE PLACED ON A SURFACE CLEARED OF GROWTH AND DEBRIS, AND BE PROPERLY BENCHED AND DRAINED. 17. ALL FILL MATERIAL, UNLESS A PERMIT FROM NCDEQ DIVISION OF WASTE MANAGEMENT TO OPERATE A LANDFILL IS ON FILE FOR THE OFFICIAL SITE, SHALL BE FREE OF ORGANIC OR OTHER DEGRADABLE MATERIALS, MASONRY, CONCRETE AND BRICK SIZES EXCEEDING 12 INCHES, AND ANY MATERIALS WHICH COULD CAUSE THE SITE TO BE REGULATED AS A LANDFILL BY THE STATE OF NORTH CAROLINA. EROSION CONTROL MAINTENANCE NOTES: 1. INSPECT EROSION CONTROL MEASURES ONCE A WEEK AND AFTER EVERY SIGNIFICANT RAINFALL. CONTRACTOR TO INSPECT MEASURES FOR COMPLIANCE WITH PLANS AND DETAILS; INCLUDING SEDIMENT ACCUMULATION BEYOND DETAIL ALLOWANCE, AND ALSO DAMAGE OR FAILURE OF MEASURES. 2. WHEN SEDIMENT ACCUMULATION EXCEEDS DETAIL ALLOWANCE, CONTRACTOR TO REMOVE SEDIMENT AND/OR DEBRIS, AND RELOCATE TO ANOTHER AREA WITH SEDIMENT CONTROLS. 3. WHEN MEASURES ARE FOUND TO BE DAMAGED, CONTRACTOR TO REPAIR IMMEDIATELY TO BRING MEASURE BACK INTO COMPLIANCE WITH PLANS AND DETAILS. 4. IF MEASURES ARE FOUND TO BE INSUFFICIENT, CONTRACTOR TO INSTALL ADDITIONAL MEASURES AS NEEDED TO ENSURE SEDIMENT REMAINS CONTROLLED ONSITE AS REQUIRED. 5. CONTRACTOR TO REMOVE MEASURES AND BRING AREA TO GRADE ONCE CONFORMATION OF SITE STABILIZATION HAS BEEN REQUESTED AND RECEIVED FROM PROJECT ENGINEER. 1 CDC INSPECTIONS HOTLINE: 828-771-4755 OR INSPECTION@CDCGO. COM Know what's below. ""`_ Call before you dig. NORTH ROUGH GRADING & EROSION CONTROL DETAILS I _ o v, w J Cn J a 0 I- w 0 J o 0 z 0 o 0 z O yr o w U) CD Z z L In CD JO z Q " 0 U z C) J J W CID Z Ln 0 rl- <_o CO N N N Q }z Q J 3: 0 c� Q z� 0 �z �w 0 J Cn �Cn C) Of Unw Y Q m E 0 U Ei o aa) o U rn � U0 0 (O U 00 • W) s V � 0, � vi vs } a N ° _ •U 0 a) O N (A CD N •; O 0 r U N �L E 0 U V) -a LO LO O � N O ,600M N � U 00 a C U V 1 V1 c1 t r � � a bu rJ99 aJ Is Is a� z x E§ w a M a s J a a 33 E Q a U) c� - v or 2 0 O 3 N �w w m U This drawing is the property of Cope Associates, Inc and is not to be reproduced without prior written authorization. This drawing is intended to be used only for the project and site specifically identified. All design information are the copyright of Cope Associates Inc. © 2020 REVISIONS NO. DATE DESCRIPTION 0 11 /04/22 ISSUED FOR BID 1 12/09/22 ADDENDUM 3 DATE: 12/2/2022 DRAWN BY: JCP a o�P 00 -Q - (_) a N.0 QI� _zQ D3.10 CHANNEL LINER INSTALLATION NOT TO SCALE DWG NO. C931 PROJECT NO. 12208 FULL SHEET SIZE: 36"X48" PEAK ROOF TRASHRACK SKIMMER (SEE DETAIL) RISER CREST ELEV. 2725.0' SEDIMENT REMOVAL MARK ELEV. 2723.5' RISER INVERT ELEV. 2722.0' CLASS B STONE PAD I I 111= 111=1LLI I1= 'I=III-III-III (4'x4'xl' MIN) l-III-III- FLEXIBLE CONNECTION TO SKIMMER (SEE DETAIL) CONCRETE ANTI -FLOATATION PAD / 1P + I I / \ PROPOSED TEMPORARY SKIMMER BASIN 'A' (SEE DETAIL D3.11, D3.14) STORAGE SURFACE AREA: 14,796 SF STORAGE DEPTH: 2' MAX. SIDE SLOPES: 2.1:1 CONTRACTOR SHALL CONVERT TO WET POND 'A' ONCE SITE IS STABILIZED AND APPROVED BY NCDEQ \ A5 \ \ \ \ 0.11 AC. \ \ / EXISTING 2' CONTOURS (TYP) \ \ \ \3X \ \ \ \ \ 3 AC. \ \ PROPOSED TEMPORARY 2' CONTOURS (TYP) \\ \ \ �C \ AC. / _ 1 , + PROPOSED EMERGENCY SPILLWAY WITH / CLASS B STONE (SEE DETAIL D3.11) ll1, C \+ BOTTOM ELEV: 2724.5' BOTTOM WIDTH: 29' SIDE SLOPES: 2:1 DEPTH: 1.5' II 0 PROPOSED TOP OF STORAGE ELEV: 2724.0')CN \ \ SB PROPOSED BASIN BOTTOM \ \ �� \\ V) ELEV.: 2722.0" ) \ \ I y I •I S PROPOSED BAFFLE (SEE DETAIL D3.15) \ I \ U) \\ \< \ PROPOSED 10' WIDE BERM ems,\ \\\\ \ ELEV 2726 0'MAIO\ \ �+ . r � TD TD 4- / / /CD ' N PROPOSED 3.0" SKIMMER WITH 3.0"0 ORIFICE (TYP) (SEE DETAIL D3.12) PROPOSED TEMPORARY 30" HDPE PIPE (1.0% MINIMUM SLOPE) (SEE DETAIL D3.13) - - SF SF SF I F rt '' SF S>F - SF �- S - SF S SF - \ _ I _ PROPOSED TEMPORARY RISER STRUCTURE \ \ - _ _ _ i log - (SEE DETAIL D3.13) - - _ - - - _ \ I 'd meanAN 1.0' MIN FREEBOARD 10. a' SELECTED FILL PLACED IN LAYERS AND COMPACTED TEMPORARY SKIMMER BASIN "A" SCALE: 1 " = 20' BERM TOP EMERGENCY SPILLWAY EMBANKMENT STABILIZED WITH VEGETATION 2.5.1 SLOPE MAX. CMP BARREL_ -III=III=III=III= _ _ _ ill-lll,��lll���llll��lll,,lll-III- ANTI -SEEP COLLAR (SEE DETAIL) L CUT-OFF TRENCH 2' DEEP, 3' BOTTOM 2:1 SIDE SLOPES SECTION THROUGH EMBANKMENT RIP RAP APRON AT OUTLET 1. LOCATE THE SEDIMENT INLETS TO THE BASIN THE GREATEST DISTANCE FROM THE PRINCIPLE SPILLWAY. 2. SEED AND PLACE MATTING FOR EROSION CONTROL ON INTERIOR AND EXTERIOR SIDESLOPES. 3. INSTALL A MINIMUM OF 3 COIR FIBER BAFFLES IN ACCORDANCE WITH NCDEQ PRACTICE STANDARD 6.65. 4. INSTALL SKIMMER AND COUPLING TO RISER STRUCTURE OR DIRECTLY INTO THE EMBANKMENT 1 FT. FROM BOTTOM OF BASIN 5. THE ARM PIPE SHALL HAVE A MINIMUM LENGTH OF 6 FT. BETWEEN THE SKIMMER AND THE COUPLING. 6. ALLOW THE MAXIMUM REASONABLE DETENTION PERIOD BEFORE THE BASIN IS COMPLETELY DE -WATERED (AT LEAST 10 HOURS). 7. REDUCE THE INFLOW VELOCITY AND DIVERT ALL SEDIMENT -FREE RUNNOFF. SEDIMENT BASIN D3.11 NOT TO SCALE ELEVATION OF OVERFLOW (SEE PLAN VIEW FOR ELEVATIONS) CONCRE STRUCTURE (� VIEW FOI SOTTO SEDIMENT 4" SCH 40 COUP FROM POND SKIN TO BE CONNECTEC 4" SCH 40 TRASH RACK 5WIDE BERM CONCRETE SLAB TEMPORARY RISER STRUCTURE D3.13 AT TEMPORARY SEDIMENT BASIN NOT TO SCALE SUPPORT POST, SUPPORT ROPE TO 24" INTO BOTTOM STAKE TO WIRE TO PREVENT SAGGING OR SIDE SUPPORT WIRE PE 'E TO TIE INTO DRM STRUCTURE =E PLAN) BAFFLE MATERIAL 11 GAUGE /\ \//\\ LANDSCAPING �j�/�//� j�/j j�// STAPLE j \C\\j\\j j\\ j\CC\/C\ STEEL POST // BAFFLE MATERIAL SHOULD BE SECURED TO THE BOTTOM OF 12 ELANDSCAPESIDES IDBASIN USING STAPLES P LE S COIR MESH OR SIMILAR, TRENCHED INTO BOTTOM OR SIDE BAFFLE DETAIL D3.15 NOT TO SCALE PROPOSED LIMITS OF DISTURBANCE (TYP) PROPOSED TEMPORARY RIP RAP APRON 'A' LENGTH: 24.0' WIDTH AT FES: 6' WIDTH AT END: 26.0' DEPTH: 18" STONE CLASS: B (SEE DETAIL D3.09) SCH 40 COUPLING CONNECTION (TYP) VENT (TYP) INLET (TYP) PROPOSED NYLON ROPE (ROPE TO RUN EMBANKMENT TO PROVIDE METHOD TO PULL SKIMMER) INLET EXTENSION SCH 40 SOLID PVC BARREL OR "ARM" SUPPLIED BY USER (TYP) HOSE (TYP) NOTES: 1. SKIMMER SHOWN IN FLOATING POSITION 2. FAIRCLOTH SKIMMER OR APPROVED EQUIVALENT 3. SKIMMER TO BE REMOVED UPON REMOVAL OF SEDIMENT TRAP 4. COUPLING CONNECTION INTO PROPOSED OUTLET STRUCTURES MUST BE SEALED UPON REMOVAL OF SKIMMER D3.12 POND SKIMMER DETAIL NOT TO SCALE MAINTENANCE NOTES INSPECT TEMPORARY SEDIMENT BASINS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN IT ACCUMULATES TO ONE-HALF THE DESIGN DEPTH. PLACE REMOVED SEDIMENT IN AN AREA WITH SEDIMENT CONTROLS. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE SKIMMER AND POOL AREA. EARTHEN EMI + + ++ + + �� C-_- - �_� + �- ++ + + INLET ZONE + + + + - - - + + 25% OF SURFACE AREA + + +-� - - + + FIRST CHAMBER + ++ + + ++ + - III -III + + + 25% OF SURFACE AREA + + + + + + - + + SECOND CHAMBER 25% OF SURFACE AREA NOTES: OUTLET ZONE 1. POROUS BAFFLE USING JUTE NET BACKED 25% OF SURFACE AREA BY COIR EROSION BLANKET (OR EQUIVALENT). 2. SEE FIGURE 6.65B OF NCDENR MANUAL OUTLET STRUCTURE FOR CROSS SECTION OF POROUS BATTLE. WITH RISER BARREL (SEE DETAIL) D3.14 SEDIMENT TRAP / BASIN BAFFLE DETAIL NOT TO SCALE SLOPE INSTALLATION 1. PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. NOTE: WHEN USING CELL-O-SEED DO NOT SEED PREPARED AREA. CELL-O-SEED MUST BE INSTALLED WITH PAPER SIDE DOWN. 2. BEGIN AT THE TOP OF THE SLOPE BY ANCHORING THE BLANKET IN A 6" (15cm) DEEP X 6" (15cm) WIDE TRENCH WITH APPROXIMATELY 12" (30cm) OF BLANKET EXTENDED BEYOND THE UP -SLOPE PORTION OF THE TRENCH. ANCHOR THE BLANKET WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30cm) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" (30cm) PORTION OF BLANKET BACK OVER SEED AND COMPACTED SOIL. SECURE BLANKET OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" (30cm) APART ACROSS THE WIDTH OF THE BLANKET. 3. ROLL THE BLANKETS (A.) DOWN OR (B.) HORIZONTALLY ACROSS THE SLOPE. BLANKETS WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL BLANKETS MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING OPTIONAL DOT SYSTEM,", STAPLES/STAKES SHOULD BE PLACED THROUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN. 4. THE EDGES OF PARALLEL BLANKETS MUST BE STAPLED WITH APPROXIMATELY 2"-5" (5cm-12.5cm) OVERLAP DEPENDING ON BLANKET TYPE. TO ENSURE PROPER SEAM ALIGNMENT, PLACE THE EDGE OF THE OVERLAPPING BLANKET (BLANKET BEING INSTALLED ON TOP) EVEN WITH THE COLORED SEAM STITCH -ON THE PREVIOUSLY INSTALLED BLANKET. 5. CONSECUTIVE BLANKETS SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END (SHINGLE STYLE) WITH AN APPROXIMATE 3" (7.5cm) OVERLAP. STAPLE THROUGH OVERLAPPED AREA, APPROXIMATELY 12" (30cm) APART ACROSS ENTIRE BLANKET WIDTH. NOTE: *IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6" (15cm) MAY BE NECESSARY TO PROPERLY SECURE THE BLANKETS. D3.16 EROSION CONTROL SLOPE MATTING INSTALLATION NOT TO SCALE 1 FILTREXX® SILT SOXXTM 2" HEADWIDTH WOODEN STAKESPLACED 10' ON CENTER FILTREXX®SILT SOXXT" (SEE PLANS FOR SIZE) AREA TO BE PROTECTED WORK AREA SECTION VIEW 2" HEADWIDTH WOODEN STAKES PLACED 10' O.C. AREA TO BE PROTECTED �o FLOW WORK AREA I I TOP VIEW NOTES: 1. ALL MATERIAL TO MEET FILTREXX®SPECIFICATIONS. OPENING 2. SILT SOXXTmFILL TO MEET APPLICATION ACCOMODATESUP REQUIREMENTS. TO V DISCHARGE 3. COMPOST MATERIAL TO BE DISPERSED ON SITE, AS HOSE DETERMINED BY ENGINEER. SILT SOCK D3.17 NOT TO SCALE FILTREXX®SILT SOXXT"^ (SEE PLANS FOR SIZE) FILTREXX® PYRAMID STAKING DETAIL (2) 2%2%48+" HARDWOOD STAKES, WRAPPED TOGETHER WITH 16 GUAGE WIRE, 10' O.C. 2%2%36" HARDWOOD STAKE, 10' O.C., STARTING 5' FROM ANGLED STAKES COMPOST SOCK CONNECTION/ATTACHMENT DETAIL OVERLAPPING SEC] FORM CONNECTION (IVH t J HY\IIV I� Ur I IUIN CLOSED END NAME DATE Itre FM auumoNaL FOPIM acaEE CON-aEr ENviaoNH<nttai DIMENSIONS ARE IN INCHES Pn eo a0-a676, WvvusEWR0NHENEoLeoa ANGULAR: BEND f 2' DRAWN DAN VIV2013 vrr�rrornrrew,a TWO PLACE DECIMAL i Ol5 W Fob"+ It THREE PLACE DECIMAL i .005 CHECKED ECO mEo CURPORA11 OFFICR • E11 DRAWING ..��.� Pk e- KFENM wWwsrsEamranEarNE.Pon CDC INSPECTIONS HOTLINE: 828-771-4755 OR INSPECTION@CDCGO. COM Know what's below. Call before you dig. NORTH ROUGH GRADING & EROSION CONTROL DETAILS 01 w O U)I.- JJ 1< 0 w 0 J J o z I_ 0 o (V, U 0 z ) V ♦ o cn 11���U w U) c� Zz o Q J 0 0 = Q " U Z O C) Of J W C0 Z Ln 0 �Co N N N Q Z Q J �O =� CD Q =O z Eof O �z =w O � J Cn n Cn oOf Lnw Y Q m 0 U N 7 O U CD.+U- cD Cn U rn ai CD c- 6 0 U (O00 41-0 V V � 0, L u•�M }a (D ° _ '7u o as o �� a: Qr oar- U N �L E 0 U V) -a L� � LOIn_0 v � N 0 N � (0 N 00 0 U V 1 V1 U t w � r � � W U Za�� Ie <imn NQ" r', b;� a�ZLL Nannwa m y 0 r 2 LL as Jaa a3 3 E Q Q CL U) vc _ .� a :z or Q1 O a N O 00 00 N 'O U �O Z x- O° O ° •N Q N a a w Z U m z This drawing is the property of Cope Associates, Inc and is not to be reproduced without prior written authorization. This drawing is intended to be used only for the project and site specifically identified. All design information are the copyright of Cope Associates Inc. © 2020 REVISIONS NO. DATE DESCRIPTION 0 11 /04/22 ISSUED FOR BID 1 12/09/22 ADDENDUM 3 DATE: 12/2/2022 DRAWN BY: JCP =Q ar _Za y°o�=�Q; DWG NO. C932 PROJECT NO. 12208 FULL SHEET SIZE: 36"X48" MINIMUM TRENCH WIDTHS ALL NON-FERROUS UNDERGROUND LINES OUTSIDE BUILDING FOOTPRINT SHALL BE REQUIRED TO HAVE A MAGNETIC -TYPE WARNING TAPE INSTALLED IN THE BACKFILL AT LEAST 6" BELOW GRADE. w w a_ o_ a_ n o N � FINAL BACKFILL (SEE SPECIFICATION FOR COMPACTION REQUIREMENT) CE w >LLJ///////////////\ > w o w \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ 0Q\\\\\�/\\\\\ o \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ w z\\\\\\\\\\\\\ -/\\\\\\\\\\\\ z x J CO w INITIAL BACKFILL (COMPACTED TO 98% SPRINGLINE E;o OF STANDARD PROCTOR) HAUNCH (COMPACTED TO 98% OF STANDARD PROCTOR) BEDDING (COMPACTED TO 98% OF STANDARD PROCTOR) SUITABLE FOUNDATION MIN. TRENCH WIDTH (SEE TABLE) PIPE DIAMETER MIN. TRENCH WIDTH 12" 30" 15" 34" 18" 39" 24" 48" 30" 56" 36" 64" 42" 72" 48" so,, 54' 88" 60 96" MAXIMUM COVER PIPE DIAMETER CLASS 1 CLASS II CLASS III 12" 43' 28' 20' 15" 43' 28' 20' 18" 43' 28' 20' 24" 34' 23' 17' 30" 34' 23' 17' 36" 34' 23' 16' 42" 34' 23' 16' 48" 31 ' 21 ' 15' 54" 31 ' 21 ' 15' 60" 31 ' 21 ' 15' To *ASSUMED PIPE BACKFILL IS PLACED AND COMPACTED TO THE REQUIRED 98% OF THE STANDARD PROCTOR NOTES: 1. ALL PIPE SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH LATEST EDITION OF ASTM D2321, "STANDARD PRACTICE FOR UNDERGROUND INSTALLATION OF THERMOPLASTIC PIPE FOR SEWERS AND OTHER GRAVITY FLOW APPLICATIONS", AND THE PROJECT SPECIFICATIONS. 2. MEASURES SHOULD BE TAKEN TO PREVENT MIGRATION OF NATIVE FINES INTO BACKFILL MATERIAL, WHEN REQUIRED. 3. FOUNDATION: WHERE THE TRENCH IS UNSTABLE, THE CONTRACTOR SHALL EXCAVATE TO A DEPTH REQUIRED BY THE ENGINEER AND REPLACE WITH SUITABLE MATERIAL AS SPECIFIED BY THE ENGINEER. AS AN ALTERNATIVE AND AT THE DISCRETION OF THE DESIGN ENGINEER, THE TRENCH BOTTOM MAY BE STABILIZED USING A GEOTEXTILE MATERIAL. 4. BEDDING: SUITABLE MATERIAL SHALL BE CLASS I, 11, OR, III. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. UNLESS OTHERWISE NOTED BY THE ENGINEER, MINIMUM BEDDING THICKNESS SHALL BE 4"(100 mm) FOR 12"-24" (100 mm - 600 mm); 6"(150 mm) FOR 30"-60" (750 mm - 900 mm). 5. HAUNCHING/INITIAL BACKFILL: SUITABLE MATERIAL SHALL BE CLASS I, 11, OR III IN THE PIPE ZONE EXTENDING NOT LESS THAN 6" ABOVE CROWN OF PIPE. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. MATERIAL SHALL BE INSTALLED AS REQUIRED IN ASTM D2321, LATEST EDITION. 6. MINIMUM COVER: MINIMUM COVER, H, IN NON -TRAFFIC APPLICATIONS (GRASS OR LANDSCAPE AREAS) IS 12" FROM THE TOP OF PIPE TO GROUND SURFACE. ADDITIONAL COVER MAY BE REQUIRED TO PREVENT FLOTATION. FOR TRAFFIC APPLICATIONS, MINIMUM COVER, H, IS 12" UP TO 48" DIAMETER PIPE AND 24" OF COVER FOR 54"-60" DIAMETER PIPE, MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT OR TO TOP OF RIGID PAVEMENT. HEAVY CONSTRUCTION LOADS MAY REQUIRE ADDITIONAL COVER TO PROTECT THE PIPE. CONTRACTOR TO VERIFY THAT CONSTRUCTION LOADS WILL NOT DAMAGE INSTALLED PIPES AND PROTECT INSTALLED PIPES IF REQUIRED. 7. MAXIMUM COVER: MAXIMUM COVER SHALL BE MEASURED FROM THE FINISHED SURFACE OF THE GROUND TO THE TOP OF THE PIPE, AND SHALL BE LESS THAN THE MAXIMUM VALUES SHOWN IN THE CHART WITHIN THIS DETAIL. D4.01 HDPE TRENCH INSTALLATION DETAIL NOT TO SCALE STANDARD SCHEDULE TOP O.D. HEIGHT 6" 8 SLAB WT./LBS 702 940 O.D. HEIGHT 0.67' 1.33' 2.67 RISER WIABS 503 998 2,003 SOLID O.D. HEIGHT 3.0' 3.5' BASE WT/LBS 1,934 2,161 SEE SCHEDULE TOP SLAB RISER SEJ� E SCHEDULE WAFFLE BASE SEE SCHEDULE SOLID TOP OR ACCESS OPENINGS AS REQUIRED LIFTING HOLES (4) LIFTING HOLES (4) 36" 16 36" y NOTES 1. CONCRETE: 28 DAY COMPRESSIVE STRENGTH f'e= 4,000 psi 2. STEEL REINFORCEMENT: ASTM A-615, GRADE 60 3. WAFFLE BOXES MEET N.C.D.O.T. APPROVAL TO 10' DEPTH 4. SOLID BOXES MEET H-20 LOADING TO 15' DEPTH 5. SOLID BOXES APPROVED FOR N.C.D.O.T STANDARDS: 840.01, 840.02, 840.04, 840.05, 840.11, 840.12, 840.14, 840.15, 840.17. 840.18, 840.19, 840.26, 840.27, 840.28, 840.31, 840.32, 840.41, 840.45 D4.04 2' X 2' YARD INLET NOT TO SCALE SHALLOW TYPE (5 FEET OR LESS IN DEPTH) SEE NOTE 'A' LO 0 w w 6" MIN. 26" X w 0 � o MIN. 6" WASHED STONE BEDDING INTERMEDIATE TYPE (4'X4' INTERIOR (5 FEET TO 20 FEET IN DEPTH) STANDARD STANDARD - STEPS 16" STEPS 16" ON 36" - ON CENTER CENTER 6" MIN. 48" CT� . N. 6" WASHED STONE BEDDING SEE NOTE 'A' REINFORCED CONCRETE SLAB MIN. 6" WASHED STONE BEDDING FOR CURB INLET: FRAME, GRATE & HOOD PER D.O.T. STD. 840.03E FOR GRATE INLET: FRAME, GRATE & HOOD PER D.O.T. STD. 840.16 FOR JUNCTION BOX: FRAME & COVER PER D.O.T. STD. 840.54 FOR CONVEX INLET: FRAME, GRATE & HOOD PER NEENAH CONVEX INLET GRATE R-2577 NOTES: 60" 1. CONCRETE SHALL BE 4000 PSI MIN. FOR ALL PRECAST CONCRETE CATCH BASINS. 2. PRECAST CONCRETE STRUCTURES MAY ONLY BE INSTALLED 6 SLAB THICKNESSAND TO DEPTHS CERTIFIED AS ACCEPTABLE BY THE REINFORCEMENT MANUFACTURER. 36., FOR SOIL AND ��► TRAFFIC LOADING BY 3. "WAFFLE" BOXES ARE ACCEPTABLE FOR SHALLOW TYPE AN ENGINEER CATCH BASINS UP TO 10' DEEP PER D.O.T. 4. PRECAST CONCRETE CATCH BASINS SHALL CONFORM TO NCDOT STD. 840.02. SLAB DETAIL PRECAST CONCRETE CATCH BASIN DETAILS FOR D4.02 GRATE INLETS, CURB INLETS, AND JUNCTION BOXES NOT TO SCALE INCOMING a FLARED END SECTION MATERIAL TO MATCH MATERIAL OF INCOMING PIPE PIPE OUTLET TO FLAT AREA NO WELL-DEFINED CHANNEL PIPE OUTLET TO WELL-DEFINED CHANNEL PLAN PLAN Le La RM ° FILTER BLANKET FILTER BLANKET �7 SECTION AA SECTION AA NOTES: 1. La IS THE LENGTH OF THE RIP RAP APRON. 2. d = 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT LESS THAN 6" (MINIMUM IS 24" DEEP IF STONE IS CLASS 11) 3. IN A WELL-DEFINED CHANNEL, EXTEND THE APRON UP THE CHANNEL BANKS TO AN ELEVATION OF 6" ABOVE THE MAXIMUM TAILWATER DEPTH OR TO THE TOP OF THE BANK, WHICHEVER IS LESS. 4. A FILTER BLANKET OR FILTER FABRIC SHOULD BE INSTALLED BETWEEN THE RIP RAP NOTES: AND SOIL FOUNDATION. 1. THE DIMENSION OF THE THE FLARED END 5. COMPACT ANY REQUIRED FILL TO DENSITY OF SURROUNDING UNDISTURBED MATERIAL. 6. RIP RAP MAY BE FIELDSTONE OR ROUGH QUARRY STONE AND SHALL BE HARD. SECTION SHALL BE PER MANUFACTURER'S ANGULAR AND WELL -GRADED. SPECIFICATIONS. 7. CONSTRUCT APRON AT ZERO GRADE. TOP OF RIP RAP SHALL BE LEVEL WITH THE 2. THE SKIRT SECTION OF THE FLARED END RECEIVING CHANNEL OR SLIGHTLY LOWER. SECTION SHOULD BE JOINED TO THE INCOMING 8• ALIGN APRON WITH RECEIVING CHANNEL OR STREAM. ASSURE APRON IS STRAIGHT PIPE PER MANUFACTURER'S SPECIFICATIONS. THROUGHOUT ITS LENGTH. 9. END WIDTH OF APRON TO BE EQUAL TO WIDTH OF RECEIVING CHANNEL. D4.05 FLARED END SECTION WITH RIP -RAP APRON NOT TO SCALE PLAN ELEVATION H2 W1 E ;TYP) 3" DIA. DRAINS 6" ABOVE FLOW LINE W2 FRONT ELEVATION REBAR (TYP) PLAN REBAR (TYP) SIDE ELEVATION NOTE: HEADWALL DIMENSIONS (METAL PIPE) USE NEXT LARGEST SIZE FOR CONCRETE PIPE. INSIDE DIAMETER OF PIPE W1 W2 H1 H2 D E WEIGHT SQ. FT. BASE AREA 12"-15"-18" 3'-2" 4'-10" V-3" 3'-2" 1'-3" 1'-9" 1,550 7.34 21-24" 3'-8" 6'-1" 1'-91, 3'-8" V-6" 2'-3" 2,100 9.90 30" 4'-2" 7'-2" 2'-0" 4'-2" 1'-10" 2'-9" 2,850 13.50 36" 4'-8" 8'-4" 2'-4" 4'-8" 2'-2" 3'-3" 3,700 17.65 42"-48" 5'-8" 10'-10" 3'-3" 5'-8" 2'-11" 4'-3" 5,600 28.60 54"-60" 6'-10" 1 V-9" 3'-6" 6'-8" 3'-4" 5'-2" 7,500 36.27 66"-72" 8'-1" 12'-0" 3'-8" 7'-7" 3'-4" 6'-2" 8,500 40.00 84"-96" 9'-4" 12'-8" 4'-0" 9'-6" 3'-4" 7'-6" 10,000 44.00 N 0 TE: 1. CONCRETE HEADWALL REINFORCEMENT PER N.C.D.O.T. STANDARD NO. 838.39 REVISION A. 2. WORK MUST BE ACCOMPLISHED SO THAT WET CONCRETE DOES NOT CONTACT STREAM WATER. REINFORCED CONCRETE HEADWALL D4.03 NOT TO SCALE NEENAH R-1975-B HANDHOLE FRAME & LID OR APPROVED EQUAL U) z Q J N z w V0 J w z � z � z� w - 0 co z 0 m 1.0% MIN. SCORIATED LID LETTERED "STORM" FINISH GRADE 4" THREADED CLEAN -OUT PLUG 45` BEND \✓/ 45` WYE BRANCH OR 45` BEND AS REQUIRED BY SITE PLAN III NOTE: 1. 4000 PSI CONCRETE STANDARD EXTERNAL DOWN SPOUT (SEE ARCHITECTURAL PLANS) 6" UNIVERSAL DOWN SPOUT CONNECTION PLUG (FERNCO USDS-6P OR APPROVED EQUIVALENT) 6" DOWN SPOUT COLLECTION PIPE (CONTRACTOR TO COORDINATE WITH ARCHITECT FOR ANY SUPERCEDING DOWN SPOUT CONNECTION DESIGNS AND LOCATIONS) PROVIDE STONE BEDDING FROM 6" BELOW PIPE TO TOP OF PIPE FOR FULL TRENCH WIDTH. 45` BEND (TYP) (AS REQUIRED) NOTES: 1. CLEAN -OUT PIPE AND FITTINGS SHALL BE SAME MATERIAL AS THE DOWNSPOUT COLLECTION PIPE. SEE PLAN FOR PIPE SIZES. CLEAN -OUT WYE TO BE SAME DIAMETER AS LATERAL. RISER, PIPE AND THREADED PLUG TO BE 4". 2. WHERE CLEAN -OUTS ARE LOCATED IN SIDEWALKS OR PAVEMENT, CAST HANDHOLE LID IN PLACE AND FLUSH WITH FINISH GRADE. 3. CONTRACTOR TO COORDINATE WITH ARCHITECT FOR ANY SUPERCEDING EXTERNAL DOWN SPOUT COLLECTION SYSTEM CONNECTION DESIGNS AND LOCATIONS DOWN SPOUT COLLECTION PIPE AND CLEANOUT D4.O6 NOT TO SCALE CDC INSPECTIONS HOTLINE: 828-771-4755 OR INSPECTION@CDCGO. COM Know what's below. Call before you dig. DEVELOPMENT DATA OWNER/DEVELOPER: CONTACT: CIVIL ENGINEER: CONTACT: SURVEYOR: CONTACT: ARCHITECT: CONTACT: PROJECT DATA MITCHELL COUNTY SCHOOLS 72 LEDGER SCHOOL ROAD BAKERSVILLE NC 28705 KIM HODSHON (828)766-3437 CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, INC 28801 MICHAEL CAIN, P.E. (828) 252-5388 BLACKROCK SURVEYING & LAND DESIGN, PC PO BOX 8302 ASHEVILLE, INC 28814 ROBERT K. BRADY, JR (828) 225-4341 COPE ARCHITECTURE 2607 KINGSTON PIKE, SUITE 5 KNOXVILLE, TN 37919 JAKE MCREYNOLDS (865) 694-9000 PIN: 0872-70-6960 ADDRESS: 5085 S. NC HWY 226 BAKERSVILLE, NC DEED BOOK/PAGE: 608/934 SITE ACREAGE: 14.93 ACRES ZONING: SNOW CREEK TOWNSHIP SETBACKS: N/A DISTURBED AREA: 12.26 AC PARKING CALCULATIONS: HANDICAPPED SPACES: SPACES REQUIRED: 5 SPACES PROVIDED: 5 VAN SPACES REQUIRED: 1 SPACES PROVIDED: 5 VEHICULAR MINIMUM REQUIRED: N/A AMOUNT PROVIDED: 117 BUILDING DATA: BUILDING DESCRIPTION HEIGHT GFA PROPOSED MIDDLE SCHOOL XX' 70,580 SF IMPERVIOUS CALCULATIONS: IMPERVIOUS PERVIOUS PRE -DEVELOPMENT: 0.11 ACRES (1%) 14.82 ACRES (99%) POST -DEVELOPMENT: 3.54 ACRES (24%) 11.39 ACRES (76%) SOIL TYPE EcC, EcD, BdA, Ud, SaB, EdE, EcC, & ScC SOIL GROUP: B, C, &D STORM DRAINAGE DETAILS U) J O OJ O V, CV♦^O o _n J a�U w o Li( ' �) CD Q z Of J 0 �UC) o' 0 0 cn J J W 00 Z UM 5� G Ln 0 r` �o CO N N N Q }z Q J 3: c� Q z00f 0 �z Dw 0 U� J COCn CD of Lnw Y Q m 0 U 0 a) o O) U W rn CD0 Q 6 0 U V � 0, L u•�M N N a ° _ '7u o as O N Q r O � r U N �k W V 1 V1 U t r � �C O U 'EAR I <imn BE; GJ99 a WW a, z LL =f E w w a m Vo r O LL w3 Q Q CL v W O 3 U1:3U 3 N 0 00 00 N 'O U �O Z w z U m Z This drawing is the property of Cope Associates, Inc and is not to be reproduced without prior written authorization. This drawing is intended to be used only for the project and site specifically identified. All design information are the copyright of Cope Associates Inc. © 2020 REVISIONS NO. DATE DESCRIPTION 0 11 /04/22 ISSUED FOR BID 1 12/09/22 ADDENDUM 3 DATE: 12/2/2022 DRAWN BY: JCP /6, ' _Jm -vain U � C.D°W= y°o�=�Q; o ° DWG NO. C941 PROJECT NO. 12208 FULL SHEET SIZE: 36"X48" PROPOSED TOP VIEW OF CONTROL STRUCTURE PROPOSED WET POND "A" (SEE DETAIL THIS SHEET) ���� PROPOSED MAIN POOL MAIN POOL ELEV.: 2725.0" U) SURFACE AREA: 8,909 SF MAX. SIDE SLOPE: 3:1 TM J PROPOSED 2' CONTOURS (TYP) MAX. DEPTH: 5' BOTTOM ELEV. 2720.0' Stor a x3'O FLAT RACK SIDE WEIR � PLASTIC SOLUTIONS, INC. o J �TRASH RACK OR APPROVED EQUAL (877) 877-5727 ♦ \ ILL CD o CD N CO \ \ \ 5 \ \ S ; L~ N a \ U N i In r 0 J L� V/ � PROPOSED OUTLET CONTROL STRUCTURE \ 4"X4" 6/6 WELDED WIRE I I Q Z Q \ (SEE DETAILS D4.09, D4.10, D4.11) FABRIC (EACH SIDE & TO I i i Z W = I a o J z1 REBAR PERIMETER FRAME I Q O C• \ / / \ FRAME (2'X2'X2') \ \ \ C\ \ \ \ \ PROPOSED STORM PIPE j j _ 4 i o L,.; 1 \ \ \ \ S (TYP)(SEE DETAIL D4.01) 2' I i %f cn J �_ 00 1 I ; ; F oN \ \ O \ \ \ I I • • W ` s' ILLJ 0:111 CID \ \ \ m \\ \ \\ 6" 8" DIP SIDE VIEW1E11�1 PROPOSED PERMANENT RIP RAP APRON 'AO' L- E > \ I LENGTH: 23.0' 3000 PSI CONCRETE WIDTH AT FES: 9.0' \ / / \ \ o ( •� AVAILABLE OPTIONS WEIR DIMENSIONS \ I 1 WIDTH AT END: 26.0' 95 DEPTH: 18" 3' REMOVABLE ACCESS PANELI WEIR OPENING WIDTH (in) "A" STONE CLASS: B ANTI VORTEX PLATEI WEIR OPENING LENGTH (in) (SEE DETAIL D3.09) D4.10 PROPOSED VEGETATIVE SHELF MIN. WIDTH: 6' MAX. SLOPE: 6:1 \\ I i `� I // \\ D4.09 8" DRAIN TRASH GUARD DETAIL \ \ I I I II I` / ` • / \ NOT TO SCALE \ I I I I \ \ \ THE DAM STRUCTURE, INCLUDING FRONT AND BACK EMBANKMENT SLOPES, OF THE POND SHALL BE VEGETATED WITH NON —CLUMPING TURF GRASS; TREES AND WOODY SHRUBS SHALL NOT BE ALLOWED; AND THE VEGETATED SHELF SHALL BE PLANTED WITH A MINIMUM OF THREE DIVERSE SPECIES OF HERBACEOUS, NATIVE VEGETATION AT A MINIMUM DENSITY OF 50 PLANTS PER 200 SQUARE FEET OF SHELF AREA. _ J \ PLANTS SHOULD BE LONGLEAF LOBILLIA, CARDINAL FLOWER, / — I I \ \ \ \ AND STARUSH WHITETOP mv) \\\ � E B 0 o CD I I I /�p �ommoommommon limil on Ion onion on on on no IIIIIIIIII I 000�00If0001�®�� 4.0' 1. D. m a` )i T �OOCOOOOC�©�© 5.0' 0. D. ° o �OOC®���®�© �� `�`� TOP CIO 3: �� iI �8 HANDLE C� lolls I / I 18p, I=-- — MANHOLE FRAME V — / AND LID TO BE 0) STRUCTURAL HDPE PLASTIC PLACED DIRECTLY a _ — — — — / OVER STAIRS •— 0) TOP VIEW TRASH RACK ASSEMBLY ELEVATED TOP S (n %7 PIS, PLASTIC SOLUTIONS, INC. "^� rI V V w TRASH RACK OR EQUA 6' I�' C 0 1-877-877-5727 — 0) V1 - - / FOREBAY BOTTOM ELEV. 2721.0' — _ — — / / � N PROPOSED 10' WIDE BERM C C m S���G�1� 00 C ++ C CONCRETE RISER ��Q ��� �O N FOREBAY ELEV. 2722.0' \// / / / C / CD a On 0) C w T A` Q)Y_ / / / / / _ R�^ �a0 0 Y — — D / s�V. sEE ci N cC PLASTIC PRECAST OR 8" BRICKS \ I W/ 1 2" 1:2 MORTARSOLUTIONS E INC. ON OUTSIDE AND INSIDE a°. a ui \ a. P.O. Box 4386 EG P — 3: I _ Winchester VA 22604 5 LID C 877-877-5727 E�E�' 11 T / It ELEV. A xmw.plastic-solution.com ELEV. B �V- G N N p INTERIOR N CV U CO w � PEAK ROOF TRASH RACK NOTE: PROPOSED WET POND "All D4.11 NOT TO SCALE CORE OPENINGS TO ACCOMMODATE PROPOSED PIPES. (REFER TO PLAN SCALE: 1 20' EXISTING 2' CONTOURS (TYP) SHEET FOR SIZE AND LOCATION OF PIPE) " = D4.12 TYPICAL OPEN THROAT DETAIL O NOT TO SCALE L � U 3 Z W rn w � 3 UW C.= s UKK OPEN TOP ELEV. 2727.0' a 2 iv T V M v 12"X12" SLOT ELEV. 2726.0' � z a 5 i� N h LL SUBMERGED 2.5" ORIFICE OUTLET ELEV. 2725.0' ` a LL a , 3 NOTE: THE RISER SHOULD BEo PLACED IN OR AT THE FACE OF THE EMBANKMENT. d o TOP OF BANK ELEV. 2729.0' MIN. V s 50-YEAR TEMPORARY POOL ? N INV. 2726.8' o 3 HT SEAL T0://\\j/3j\\/ 8 INV. 2726.1' OVERFLOW STRUCTURE OUTLET 1-YEAR TEMPORARY POOL /\ "PRQVIDED ATE\� \\/ VEGETA V \ /\// SHEL /\\/\ \\ \ \\ \\ RISER/BARREL INTERFACE \\ \ \\ \\ \\ ARMOR FORBAY WITH RIP 5' FOREBAY BERM // INV. 2725.0' PERMANENT POOL RAP AND FILTER FABRIC FOREBAY VOLUME: 6,404 CIF BERM\ \\ STRUCTURE SIDE SLOPE 3: 1 // //\\//\\�/\\%\ FOREBAY SECTION \\j\\j\\j \\j\\j\\j\ \\j\\j \/\/\/\\/\/\ \ \ \ \ \ \ \ "AO" BASIN VOLUME: 32,541 CF 5.0 /�j\\//\\//\Yj\\//\\// SIDE SLOPES 2:1 ///\\j/\\j/\\j/\\j/\\j/\\j/\\j/\\ 6 �� / w INV. 2720.0' TOP OF SEDIMENT STORAGE//\\%/\\//\\\//\\%/�\%/�\%/�\%/�\%//\\%/�\%// w WATER TIGHT 30" HDPE (BLUE SEAL OR EQ.) j�\j�\j�\jam\/ \\\\INV. 2719.0' BOTTOM OF POND\/\\/\\//\\/\/\\/\\//\\\/�\\/�\\/�\\//\\/�\\/�\\ INV. 718.5'771 �/j�//\\Y/j�/j�/j\//%\//%\///�//\//%�/%\//// This drawing is the PropertY a \\/�\\/�\\/�\\/�\\/�\\/� \\//\\//\\//\'�\ �\ �\ '�/\\\/\\/�\\/�\\/\\/�\\//\\\/�\\/�\\/ \// /\/\/\/\/ / /\j \ \ \ ��\�\/. / \// /j//\/ /\/\/i\/��//�//i/// •e' \ \ \ \ \ ,\� Cope Assodates, Inc and is not ���\��\��\��\��\\i.\r\\\/i\\/�\\��\\\/�\\��\\\/�\/\\\/i\\ \/�\ \\ \\<5•!\\/ i\\\ \/\\/\\�\\/\\/� be reproduced without prior j'ANTI-SEEP COLLAR (X2) SEEP COLLARS TO BE SPACED written authorization. This draws KEY TRENCH SEE BERM �/ /, ' is intended to be used only for e ( /�\/ MI MUM ON CENTER. COLLARS SHALL S PLACED A project and site specifically FABRIC NON -WOVEN GEOTEXTILE SOIL AND COMPACTION MINIMUM OF 2 FEET FROM PIPE JOINTS. (SEE DETAIL) SHALL BE PLACEDSPECIFICATIONS) AROUND EACH JOINT OF identified. All design informal HDPE IN 2' WIDE STRIPS are the copyright of Cope CENTERED ON JOINT. Associates Inc. © 2020 WET DETENTION POND "A" D4 08 PERMANENT DAM AND CONTROL STRUCTURE REVISIONS CROSS SECTIONS NO. DATE DESCRIPTION 0 11 /04/22 ISSUED FOR BID NOT TO SCALE 1 12/09/22 ADDENDUM 3 2 12/14/22 AGENCY SUBMITTALS 3 2/28/23 AGENCY SUBMITTALS DATE: 12/2/20 DRAWN BY: MCP ° ° �v � � oo d�J•; _¢ a°�° _zo = U a W UIt O° LL1 - 111101111111 STORM DRAINAGE DETAILS DWG NO. C942 PROJECT NO. 12208 FULL SHEET SIZE: 36 X48 SHEETED OPEN TRENCH TRENCH BACKFILL MATERIAL COMPACTED IN 6" LIFTS 111 1111 24" MAX 12' MAX BACKFILL MATERIAL 12 MIN 6 MIN COMPACTED IN 3" LIFTS BACKFILL MATERIAL COMPACTED IN 6" LIFTS BACKFILL MATERIAL COMPACTED IN 3" LIFTS SHEETED OPEN TRENCH TRENCH UNDISTURBED NOTE: EARTH UNDISTURBED BELL HOLES NOT SHOWN EARTH OVERCUT EXCAVATION STANDARD EXCAVATION SHEETED OPEN SHEETED OPEN TRENCH TRENCH TRENCH TRENCH BACKFILL MATERIAL BACKFILL MATERIAL COMPACTED IN 6" LIFTS COMPACTED IN 6" LIFTS 24" MAX 12" MAX 24' MAX 12' MAX 12 MIN 6" MIN 12" MIN \\ SPRING LINE OF PIPE ��P x< SPRING LINE OF PIPE ? i fi" MIN WASHED STONE-""6'MIN WASHED STONE�i �\ EMBEDMENT %< EMBEDMENT j\ \\` ADDITIONAL WASHED STONE FOR UNDISTURBED EARTH UNDERCUT EXCAVATION ONLY \ \ AS DIRECTED BY ENGINEER STANDARD EXCAVATION CONSTRUCTION OF TRENCHES IN WET CONDITIONS SHALL BE IN ACCORDANCE EARTH WITH THE LATEST OSHA UNDERCUT EXCAVATION REGULATIONS. CONTRACTOR IN UNSTABLE SOILS TYPES SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE REGULATIONS. NO BOULDERS OR STONES IN EXCESS OF 4" IN SIZE SHALL BE USED AS PART OF THE INITIAL BACKFILL. TYPICAL TRENCH DETAIL D6.OI NOT TO SCALE PIPE BEDDING MATERIAL SHALL BE # 57 WASHED STONE. BACKFILL IN 6"-8" LIFTS & COMPACT TO 95% STANDARD PROCTOR IF NOT IN THE ROADWAY. BACKFILL IN 6"-8" LIFTS & COMPACT TO 98% STANDARD PROCTOR WHEN IN PAVED AREAS. UNDISTURBED EARTH o N Ln cn J C3 _ n a cn Cn 6" 6 / INITIAL \\ (MIN.)\\� BACKFILL PIPE SPRING LINE \\ \/\�� PIPE INV. CL 1 EMBEDMENT 6" MATERIAL E M BE IPE D M EN T MATERIAL TRENCH FOR PVC PIPE OW DIA. AND LESS) NOT TO SCALE NOTES: 1. PVC PIPES REQUIRE CLASS I PIPE EMBEDMENT MATERIALS. 2. WHEN TRENCH IS SUBJECT TO INUNDATION, EMBEDMENT MATERIALS MUST EXTEND TO TOP OF PIPE. 3. NO BOULDERS OR STONES IN EXCESS OF 4" WILL BE USED IN INITIAL BACKFILL. 4. THIS DETAIL IS VALID FOR PVC SEWER PIPE INSTALLED AT DEPTHS OF UP TO 20 FEET. 5. PVC PIPE NOT ALLOWED WITH LESS THAN 3'-0" COVER. D6.06 TRENCH FOR PVC PIPE NOT TO SCALE l=b °• ra • •ot. TAPPING SLEEVE NOTES 1. TAPPING SLEEVE WILL BE MUELLER #H-615 OR APPROVED EQUAL. 2. APPROVED RESILIENT SEAT TAPPING VALVE. 3. SOLID CONCRETE OR BRICK BLOCKING WILL BE USED AS FOOTING FOR DUCTILE IRON PIPE. 4. CONCRETE WILL NOT CONTACT BOLTS OR ENDS OF MECHANICAL JOINT FITTINGS. 5. SEE APPROPRIATE STANDARD DETAIL FOR THRUST BLOCK AND THRUST BLOCK DIMENSIONS. 6. ALL FITTINGS AND APPURTENANCES SHALL BE RESTRAINED AS PER SECTION 6.05. D6.03 TAPPING SLEEVE AND VALVE ASSEMBLY NOT TO SCALE MAGNETIC MAGNETIC WARNING WARNING TAPE TAPE INITIAL BACKFILL INITIAL BACKFILL �vs COMPACTED TO 92% STANDARD PROCTOR COMPACTED) ') C) MAINTAIN TRENCH MAINTAIN TRENCH 5 WIDTH TO 12" WIDTH TO 12" N ABOVE TOP OF ABOVE TOP OF PIPE PIPE N C IN SOIL U w 1 IN SOIL 6" IN ROCK a_ 4" 6" IN ROCK -W= 2'- 6 1� JJ --W= 2'- 6 PIPE INV. CL 1 EMBEDMENT JJ MATERIAL TYPICAL SEWER TRENCH 8" D.I. PIPE TYPICAL SEWER TRENCH CUTS 25 FT. TO 32 FT. 8" D.I. PIPE CUTS 25 FT. & LESS NOTE: 1) DEPTHS OF CUT OR PIPE SIZES GREATER THAN THOSE SHOWN ON THE TRENCH DETAILS REQUIRE SPECIAL DESIGN AND SUBMITTAL OF DESIGN DATA BY THE ENGINEER. 2) ABOVE TRENCH DETAILS ARE FOR TRENCH INSTALLATIONS ONLY. SEWERS INSTALLED IN POSITIVE OR NEGATIVE PROJECTING LAYING CONDITIONS REQUIRE SPECIAL DESIGN AND SUBMITTAL OF DESIGN DATA BY THE ENGINEER. TRENCH FOR DIP PIPE D6.O7 NOT TO SCALE GENERAL NOTES: 1. SEE STANDARD THRUST BLOCK DIMENSIONS. 3. VALVE BOX WILL NOT CONTACT WATER MAIN OR VALVE NOTES: 2. CONCRETE SHALL NOT CONTACT BOLTS OR CONSTRUCTION OF TRENCHES ENDS OF MECHANICAL FITTINGS. 4. VALVE PAD REQUIREMENTS SHALL BE IN ACCORDANCE SHALL NOT BE APPLICABLE WITH THE LATEST OSHA REGULATIONS. CONTRACTOR FOR IMPROVED PAVED SURFACES. SHALL BE RESPONSIBLE FOR COVER o O COMPLIANCE WITH ALL TYPICAL FINISHED GRADE APPLICABLE REGULATIONS. IN PAVED AREAS NO BOULDERS OR STONES IN EXCESS OF 4" IN SIZE SHALL BE USED AS PART OF THE INITIAL BACKFILL. 1-2 PIPE BEDDING MATERIAL SHALL BE # 57 WASHED CABC -I -I -I ------------- - - STONE. -1 I -_III -_III -III -III -III -III -III -III - CAST IRON PIPE -III FOR EXTENSIONS-1-III III III III III III ;III; STANDARD BOX-BOTT SECTION APPROVED RESTRAINT DEVICE MEGALUG OR EQUAL GATE VALVE ASSEMBLY DETAIL D6.IO NOT TO SCALE STD.NO. 6.06 OX FLEXIBLE MANHOLE MANHOLE SLEEVE OR PIPE EMBEDMENT ENTRANCE JOINT MATERIAL A B PIPE EMBEDMENT MATERIAL 0 0 MANHOLE 00 °o STEPS o UNDISTURBED SECTION B-B ` a- Cpt N CAST IRON FRAME &COVER �o �� 9V o ° BRICK ADJUSTMENT a CENTERLINE OF INLET PIPING IS NOT ALLOWED a o •al.° MANHOLE o �o° IN EITHER a ° a o,` STEPS w QUADRANT C o o C zo ADJOINING THE L_°o °o MANHOLE o OUTLET. SEE ° r J�' " DETAIL D s „A„ . ° °• � A B SECTIONAL PLAN 4 MIN z GROUT INSIDE 2 ROPES ao GROUTED OR PRECAST ° JOINT °sa° BUTYL CONCRETE "U" SHAPED RUBBER CHANNEL(S) : SEALANT FLEXIBLE MANHOLE SLEEVE OR " °` Q ° ENTRANCE JOINT .° DETAIL "A" 00 1 TRENCH 2„ PIPE WIDTH EMBEDMENT MATERIAL gOgg ,OO 0000000 (300 z,. 6" PIPE SECTION C-C EMBEDMENT PIPE EMBEDMENT UNDISTURBED MATERIAL MATERIAL SECTION A -A NOTE: MANHOLE STEPS TO BE VERTICALLY IN LINE WITH "INVERT OUT" FOR PIPE 18" AND LESS. OVER 18" TO BE LOCATED IN LINE WITH BENCH. STANDARD MANHOLE D6.O4 NOT TO SCALE (7PARKING LOT SIDEWALK WHEELCHAIR 3RADIUS RAMP - - P OPOSED HYDR NT / \ 2' MIN. 5' MAX. CURB AND GUTTER 3' NO OBSTRUCTIONS _ 3 _ IN THIS AREA PARKING LOT 3' RADIUS %PROPOSED HYDRANT\ 1 NO OBSTRUCTIONS IN THIS AREA. GENERAL NOTES: 1. SEE STANDARD THRUST BLOCK DIMENSIONS. FIRE HYDRANT 2. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF MECHANICAL FITTINGS. 3. VALVE BOX WILL NOT CONTACT WATER MAIN OR VALVE 4. VALVE PAD REQUIREMENTS SHALL NOT BE APPLICABLE FOR IMPROVED PAVED SURFACES. 24 X 24" X 6" 5. LOCATION SHOULD BE COORDINATED WITH NCDOT ALONG STATE MAINTAINED ROADWAYS. CONCRETE PAD 6. OBSTRUCTION FREE AREA SHALL APPLY TO ALL LOCATIONS FOR FIRE HYDRANT INSTALLATION. 7. HYDRANT LOCATION SHALL NOT INTERFERE WITH THE REQUIREMENTS OF THE NORTH CAROLINA BUILDING CODE. STANDARD HYDRANT LOCATION D6.O8 NOT TO SCALE 3' 6" MIN. 1 /3 C.Y. OF #57 STONE MATERIALS AND CONSTRUCTION SHALL REMOVABLE ACCESS BE APPROVED BY THE ENGINEER PANEL OPENING EACH SIDE 12" SPOOL PIECE SLAB MOUNTED HEATER a a4 GATE VALVE $ (OS&Y) a 1 ° °1 4 0 ° FIRE DEPARTMENT ° FLANGED 90` BEND CONNECTION a L REDUCED PRESSURE HINGED, INSULATED DRAIN OPENING DETECTOR ASSEMBLY GENERAL NOTES FOR WATER GENERAL NOTES FOR SEWER 1. WATER CONSTRUCTION ON THIS SITE MUST BE AUTHORIZED BY PERMITS ISSUED BY THE 1. SEWER CONSTRUCTION ON THIS SITE MUST BE AUTHORIZED BY PERMITS ISSUED BY THE TOWN OF SPRUCE PINE. ALL SITEWORK SHALL BE IN ACCORDANCE WITH ALL LOCAL, STATE, TOWN OF SPRUCE PINE. ALL SITEWORK SHALL BE IN ACCORDANCE WITH ALL LOCAL, AND NATIONAL REGULATORY STANDARDS; AND ALL REQUIREMENTS IN THE PROJECT STATE, AND NATIONAL REGULATORY STANDARDS; AND ALL REQUIREMENTS IN THE TECHNICAL SPECIFICATIONS. PROJECT TECHNICAL SPECIFICATIONS. REQUIREMENTS AND SPECIFICATIONS OF TOWN OF SPRUCE PINE STANDARDS SUPERSEDE ALL OTHERS IN THE INSTALLATION OF THE 2 CONTRACTOR TO VERIFY WITH ENGINEER THAT THE REQUIRED WATER PERMITS AND PROPOSED SEWER EXTENSION. ASSOCIATED NON -WATER PERMITS HAVE BEEN OBTAINED PRIOR TO BEGINNING CONSTRUCTION. 2. CONTRACTOR TO VERIFY WITH ENGINEER THAT THE REQUIRED SEWER PERMITS AND ASSOCIATED NON -SEWER PERMITS HAVE BEEN OBTAINED PRIOR TO BEGINNING 3. ALL CONSTRUCTION SHALL BE UNDER THE OBSERVATION OF THE ENGINEER, THE OWNER, CONSTRUCTION. CONTRACTOR TO PROVIDE COPY OF STREET CUT PERMIT TO TOWN OF AND THE TOWN OF SPRUCE PINE. THE ENGINEER SHALL PERIODICALLY OBSERVE THE SPRUCE PINE PRIOR TO CONSTRUCTION. PROGRESS OF INSTALLATION AND SHALL COMPLETE A FINAL WATER AND SEWER INSPECTION. THE CONTRACTOR SHALL FURNISH, SECURE, AND PROVIDE ALL NECESSARY 3. ALL CONSTRUCTION SHALL BE UNDER THE OBSERVATION OF THE ENGINEER, THE OWNER, TESTING MATERIALS, EQUIPMENT, PROCEDURES, AND CERTIFIED LABORATORY TEST RESULTS THE TOWN OF SPRUCE PINE. THE ENGINEER SHALL PERIODICALLY OBSERVE THE FOR USE WITH ENGINEERS FINAL CERTIFICATION OF COMPLETION. ANY WORK COVERED PRIOR PROGRESS OF INSTALLATION AND SHALL COMPLETE A FINAL WATER AND SEWER TO ENGINEER'S INSPECTION IS SUBJECT TO UNCOVERING AND BACKFILLING AT THE INSPECTION. THE CONTRACTOR SHALL FURNISH, SECURE, AND PROVIDE ALL NECESSARY CONTRACTOR'S EXPENSE. TESTING MATERIALS, EQUIPMENT, PROCEDURES, AND CERTIFIED LABORATORY TEST RESULTS FOR USE WITH ENGINEERS FINAL CERTIFICATION OF COMPLETION. ANY WORK 4. ALL WORK MUST BE PERFORMED BY A NORTH CAROLINA LICENSED UTILITY CONTRACTOR. �/1 COVERED PRIOR TO ENGINEER'S INSPECTION IS SUBJECT TO UNCOVERING AND vv�� BACKFILLING AT THE CONTRACTOR'S EXPENSE. 5. CONTRACTOR IS RESPONSIBLE FOR LOCATING AND VERIFYING THE EXACT LOCATION AND ELEVATION FOR ALL UTILITIES PRIOR TO CONSTRUCTION; AND TO NOTIFY ENGINEER OF ANY O 4. ALL WORK MUST BE PERFORMED BY A NORTH CAROLINA LICENSED UTILITY CONTRACTOR. CONFLICTS OR DISCREPANCIES. THE LOCATION OF SOME UTILITIES SHOWN ON THE PLANS HAVE BEEN APPROXIMATED. ALL BURIED UTILITIES HAVE NOT BEEN SHOWN ON THE PLANS 5. CONTRACTOR IS RESPONSIBLE FOR LOCATING AND VERIFYING THE EXACT LOCATION AND AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THEIR LOCATION PRIOR TO J ELEVATION FOR ALL UTILITIES PRIOR TO CONSTRUCTION; AND TO NOTIFY ENGINEER OF CONSTRUCTION. 0 ANY CONFLICTS OR DISCREPANCIES. THE LOCATION OF SOME UTILITIES SHOWN ON THE ♦ , O PLANS HAVE BEEN APPROXIMATED. ALL BURIED UTILITIES HAVE NOT BEEN SHOWN ON 6. CONTRACTOR SHALL PROTECT EXISTING AND NEWLY BUILT UTILITIES DURING CONSTRUCTION. v O THE PLANS AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THEIR ANY DAMAGE TO UTILITIES INCURRED DURING OR RESULTING FROM CONSTRUCTION ACTIVITY �/1 o U) LOCATION PRIOR TO CONSTRUCTION. IS THE RESPONSIBILITY OF THE CONTRACTOR AND IS TO BE REPAIRED IN ACCORDANCE co 1: CO� WITH APPLICABLE STANDARDS OF APPROPRIATE AGENCIES AT THE CONTRACTOR'S EXPENSE. c. N 6. CONTRACTOR SHALL PROTECT EXISTING AND NEWLY BUILT UTILITIES DURING U CONSTRUCTION. ANY DAMAGE TO UTILITIES INCURRED DURING OR RESULTING FROM 7. THE CONTRACTOR IS TO NOTIFY ALL UTILITY COMPANIES AT LEAST 72 HOURS BEFORE �/1 Q _JCONSTRUCTION U) ACTIVITY IS THE RESPONSIBILITY OF THE CONTRACTOR AND IS TO BE CONSTRUCTION ACTIVITY IS TO BEGIN. THE CONTRACTOR SHALL NOTIFY ULOCO AT n 3 REPAIRED IN ACCORDANCE WITH APPLICABLE STANDARDS OF APPROPRIATE AGENCIES AT 1-000-632-4949 OR 811, 72 HOURS BEFORE CONSTRUCTION BEGINS. NOTIFY THE a W THE CONTRACTOR'S EXPENSE. ENGINEER AT LEAST 72 HOURS BEFORE STARTING CONSTRUCTION ACTIVITIES. = w =) o J 7. THE CONTRACTOR IS TO NOTIFY ALL UTILITY COMPANIES AT LEAST 72 HOURS BEFORE 8. EROSION CONTROL IS FIELD PERFORMANCE BASED AND CONTRACTOR SHALL INSTALL AND � z O C)O CONSTRUCTION ACTIVITY IS TO BEGIN. THE CONTRACTOR SHALL NOTIFY ULOCO AT MAINTAIN ANY EROSION CONTROL MEASURES NECESSARY TO ASSURE MAXIMUM J 1-800-632-4949 OR 811, 72 HOURS BEFORE CONSTRUCTION BEGINS. NOTIFY THE PROTECTION OF THE SITE. CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL 1 C)o ENGINEER AT LEAST 72 HOURS BEFORE STARTING CONSTRUCTION ACTIVITIES. MEASURES REQUIRED TO CONTROL SEDIMENT DURING INSTALLATION ALL WATER PIPES AND cn APPURTENANCES. J n 8. CONTRACTOR SHALL PROVIDE THE TOWN OF SPRUCE PINE FIELD DENSITY REPORTS Cn J o � a VERIFYING SEWER BUILT IN FILL AREAS ARE COMPACTED TO 95% STANDARD PROCTOR. 9• ALL WATER LINES AND SERVICES SHALL BE CONSTRUCTED IN ACCORDANCE WITH NC Y PLUMBING CODES AND THE TOWN OF SPRUCE PINE. COORDINATE EXACT LOCATIONS OF W M M 9. EROSION CONTROL IS FIELD PERFORMANCE BASED AND CONTRACTOR SHALL INSTALL SERVICE LINES AND APPURTENANCES WITH THE ARCHITECTURAL, PLUMBING, AND ' AND MAINTAIN ANY EROSION CONTROL MEASURES NECESSARY TO ASSURE MAXIMUM LANDSCAPING PLANS. M PROTECTION OF THE SITE. CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL MEASURES REQUIRED TO CONTROL SEDIMENT DURING INSTALLATION ALL SEWER PIPES 10. CONTRACTOR TO PROVIDE 5' MIN. LATERAL SEPARATION BETWEEN WATER LINE AND OTHER AND APPURTENANCES. UNDERGROUND UTILITIES. SEE DETAILS FOR GENERAL NOTES CONCERNING WATER MAIN INSTALLATION REQUIREMENTS. 10. SAFETY AND TRAFFIC ROUTING TO BE COORDINATED WITH TOWN OF SPRUCE PINE AND IN STRICT ACCORDANCE WITH NCDOT GUIDELINES FOR CONSTRUCTION, MAINTENANCE, 11. A 3' COVER DEPTH SHALL BE MAINTAINED FOR ALL PROPOSED WATER LINES, ANY AND UTILITY OPERATIONS. NECESSARY FIELD ADJUSTMENTS MUST BE APPROVED BY THE ENGINEER AND THE CITY INSPECTOR. 11. ALL SEWER SERVICES SHALL BE CONSTRUCTED IN ACCORDANCE WITH NC PLUMBING CODES AND ANY REQUIREMENTS PER LOCAL AUTHORITIES. COORDINATE EXACT 12. INSTALL FERROUS PIPING FOR BOTH WATER AND SEWER WITHIN 10' OF A CROSSING IF: LOCATIONS OF SERVICE LINES WITH THE ARCHITECTURAL, PLUMBING, AND LANDSCAPING A. SEWER LINE CROSSES OVER WATER, OR PLANS. SEWER CLEANOUT ASSEMBLY LOCATIONS SHOWN ARE APPROXIMATE AND ARE B. VERTICAL CLEARANCE BETWEEN WATER AND SEWER IS LESS THAN 18". SUBJECT TO FINAL VERIFICATION. MAINTAIN 10' HORIZONTAL SEPARATION BETWEEN SEWER AND WATER MAINS UNLESS LAID IN SEPARATE TRENCHES WITH THE BOTTOM OF THE WATER LINE AT LEAST 18" ABOVE THETOP 12. ALL NON-FERROUS UNDERGROUND SERVICE LINES OUTSIDE BUILDING FOOTPRINT SHALL OF SEWER OR USE FERROUS MATERIAL FOR BOTH WATER AND SANITARY SEWER. BE REQUIRED TO HAVE A MAGNETIC- TYPE WARNING TAPE INSTALLED IN THE BACKFILL AT LEAST 6" BELOW GRADE. 13. MAINTAIN 18" VERTICAL SEPARATION BETWEEN STORM DRAIN AND WATER OR THE WATER MAIN MUST BE CONSTRUCTED OF FERROUS MATERIALS FOR A DISTANCE OF AT LEAST 13. CONTRACTOR TO INSTALL D.I.P. WHERE THE MINIMUM OF 3' COVER OR AT UTILITY 10-FEET TO EITHER SIDE OF THE CROSSING. CROSSINGS WHERE MINIMUM VERTICAL SEPARATION REQUIREMENTS CANNOT BE MET. PIPE MATERIAL MUST TRANSITION TO D.I.P. 10' PRIOR TO CROSSING VIA A SOLID SLEEVE 14. MAINTAIN 5' HORIZONTAL DISTANCE BETWEEN WATER LINES AND THE DRIP LINE, AT COUPLING AND EXTEND TO THE NEXT MANHOLE. MATURITY, OF TREES AND OTHER SHRUBS. 14. INSTALL FERROUS PIPING FOR BOTH WATER AND SEWER WITHIN 10' OF A CROSSING IF: 15. TOWN OF SPRUCE PINE OWNERSHIP AND MAINTENANCE ENDS AT WATER METER AND/OR A. SEWER LINE CROSSES OVER WATER, OR THE FIRE LINE ISOLATION VALVE. WATER SYSTEM BEYOND IS TO BE PRIVATELY OWNED AND B. VERTICAL CLEARANCE BETWEEN WATER AND SEWER IS LESS THAN 18". MAINTAINED. MAINTAIN 10' HORIZONTAL SEPARATION BETWEEN SEWER AND WATER MAINS UNLESS LAID IN SEPARATE TRENCHES WITH THE BOTTOM OF THE WATER LINE AT LEAST 18" 16. METERS, VAULTS, AND FIRE HYDRANTS ARE TO BE PLACED IN RELATIVELY FLAT AREAS. ABOVE THE TOP OF SEWER OR USE FERROUS MATERIAL FOR BOTH WATER AND SANITARY SEWER. 17. BRASS FITTINGS MUST BE LEAD FREE PER TOWN OF SPRUCE PINE REQUIREMENTS. 14. MAINTAIN 18" VERTICAL SEPARATION BETWEEN STORM DRAIN AND SANITARY SEWER, OR 18. CONTRACTOR RESPONSIBLE FOR ADJUSTING EXISTING WATER APPURTENANCES AS E INSTALL FERROUS MATERIAL ON THE SANITARY SEWER WITHIN 10' EACH SIDE OF THE NECESSARY DUE TO ANY SITE CONSTRUCTION OR INSTALLATION. CROSSING. 19. TRENCH BACKFILL AND COMPACTION TESTING SHALL BE PERFORMED BY A CERTIFIED 0 U 15. CONTRACTOR RESPONSIBLE FOR ADJUSTING EXISTING WATER APPURTENANCES AS SOILS LABORATORY UNDER ALL PAVED AREAS. o CD -2 NECESSARY DUE TO ANY SITE CONSTRUCTION OR INSTALLATION. °' 2 v (o 20. CONTRACTOR SHALL SUPPLY THE ENGINEER WITH RECORD OF DEVIATIONS FROM PLANS 16. TRENCH BACKFILL AND COMPACTION TESTING SHALL BE PERFORMED BY A CERTIFIED FOR PREPARATION OF FINAL RECORD DRAWINGS. 6 o SOILS LABORATORY UNDER ALL PAVED AREAS. 00 21. PRESSURE TEST WATER MAINS TO 200 PSI MIN. AND 250 PSI MAX. AS PER TOWN OF 17. THE ENTIRE SEWER EASEMENT MUST BE CLEAR AND REMAINED CLEARED OF TREE SPRUCE PINE REQUIREMENTS. DISINFECT WATER LINES AND PROVIDE ACCEPTABLE PLANTINGS, EXISTING TREES, AND ANY PERMANENT STRUCTURES. BACTERIOLOGICAL TEST FROM A CERTIFIED TESTING LABORATORY FOR USE WITH THE V ENGINEERS CERTIFICATION OF COMPLETION. 18. CONTRACTOR SHALL SUPPLY THE ENGINEER WITH RECORD OF DEVIATIONS FROM PLANS 22 THE PERMITS REQUIRE CERTIFICATION OF COMPLETION BY THE ENGINEER OF THE WATER FOR PREPARATION OF FINAL RECORD DRAWINGS. SYSTEM PRIOR TO ISSUANCE OF FINAL OPERATION APPROVAL BY THE TOWN OF SPRUCE •� 19. THE PERMITS REQUIRE CERTIFICATION OF COMPLETION BY THE ENGINEER OF THE SEWER PINE. SERVICE WILL BE PROVIDED ONCE FINAL CLOSEOUT SUBMITTALS HAVE BEEN S VARIESSYSTEMS PRIOR TO ISSUANCE OF FINAL OPERATION APPROVAL BY THE TOWN OF APPROVED BY THE TOWN OF SPRUCE PINE'S ENGINEERING DEPARTMENT. (� SPRUCE PINE. SECURE FINAL OPERATIONAL APPROVAL FROM TOWN OF SPRUCE PINE L � M D PRIOR TO ACTIVATION OF THE SYSTEM. 23. CROSS -CONNECTION CONTROL PROTECTION DEVICES ARE REQUIRED BASED ON DEGREE U to OF HEALTH HAZARD INVOLVED AS LISTED IN APPENDIX-B OF THE RULES GOVERNING Qy PUBLIC WATER SYSTEMS IN NORTH CAROLINA. THESE GUIDELINES ARE THE MINIMUM N REQUIREMENTS. THE DEVICES SHALL BE LISTED ON THE UNIVERSITY OF SOUTHERN d (D 1'- 6" MIN. CALIFORNIA APPROVED ASSEMBLIES. THEY SHALL BE INSTALLED AND TESTED (BOTH 0 C = FINISHED GRADE D 2'- 0" MAX. INITIAL AND PERIODIC TESTING THEREAFTER IN ACCORDANCE WITH THE 0 N '� MANUFACTURER'S RECOMMENDATIONS OR THE LOCAL CROSS -CONNECTION CONTROL 0 y v v v v v PROGRAM, WHICHEVER IS MORE STRINGENT. (A �V ,I_��.., ,. •.'. -II III-III�III-III I' C � u u. 24. RESTRAINED JOINTS BY AN APPROVED PIPE MANUFACTURER ARE TO BE USED FOR ALLIF Q �; 24" X 24" X 6" CONCRETE PAD PUBLIC LINES WHERE THRUST RESTRAINING IS REQUIRED; HOWEVER, THRUST BLOCKS QO x VALVE BOX Er �' ARE PERMITTED WHERE CONNECTIONS ARE MADE TO EXISTING WATER LINES OR WHERE 0 0C 6" GATE VALE-\ 8" MAX. THE USE OF MECHANICAL RESTRAINT IS NOT FEASIBLE. U CV he 1 BE � III- III I-_Il�ll ik CONCRETE SUPPORT PAD II n�l� -�-11 Ilm��r APPROVED RESTRAINT DEVICE MEGALUG OR EQUAL FIRE HYDRANT ASSEMBLY D6.O9 NOT TO SCALE GATE VALVE (OS&Y) 3" ROOF INSULATION PREFABRICATED, INSULATED METAL ENCLOSURE AS APPROVED BY ENGINEER _ REMOVABLE ACCESS PANEL1" MIN. W/ LOCK AND HINGED DRAIN DOOR SIZED FOR 11 /2" WALL _ _ FULL DISCHARGE. INSULATION FLANGED 90` BEND ® ® 12" SPOOL PIECE FLANGED 90` BEND FIRE DEPARTMENT I CONNECTION i� 6" MIN. VY YVIt I 6" MIN. HINGED DRAIN DOOR 6" MIN 6 SLAB MOUNTED 12 HEATER a a a Q -III-M_-0III MI 1 �Iwii I- -III , II-1-I I-III-III-III-III-III-1 =1 I I -I I I -I I I -I I '- 11-1 11-1 6" MIN. �1 1���=III-1j1- COMPACTED EARTH 6" WASHED STONE 6" MIN. SUPPLY CUSTOMER �D p PROVIDE BRACES (TYP.) FLANGED 90` BEND INSULATED COVER INSIDE DIMENSIONS RECOMMENDED CONCRETE PAD DIMENSIONS FIRE LINE SIZE W L H WIDTH LENGTH 6" 38" 100" 64" 53 115" ABOVE GROUND ENCLOSURE FOR D6.11 REDUCED PRESSURE ZONE ASSEMBLY NOT TO SCALE PROVIDE BRACES (TYP.)i a FLANGED 90` BEND NOTES: 1. WHERE SPRINKLE SYSTEMS ARE USED, A FIRE DEPARTMENT CONNECTION SHALL BE PROVIDED ON THE BUILDING OR AS OTHERWISE APPROVED BY FIRE OFFICIAL. CONNECTION LOCATION(S) MUST BE APPROVED BY FIRE OFFICIAL. 2. WHERE SPRINKLE SYSTEM OR A RISER ROOM ARE REQUIRED OUTSIDE ACCESS IN ACCORDANCE WITH THE N.C. BUILDING CODE SHALL BE PROVIDED. BACKFLOW PREVENTION FOR SPRINKLE SYSTEMS MUST COMPLY WITH SECTION 6.11 OF THE STANDARDS. 3. CONTRACTOR SHOULD PROVIDE ELECTRICAL SERVICE TO THE SLAB MOUNTED HEATER PER LOCAL AND STATE REQUIREMENTS. DIMJ OR HYDRANT "TEE" A FLOW_ L ACCESS DOOR AS MANUFACTURED BY BILCO, HOLIDAY OR EQUAL �A @AN6 ,OLOECSTEPS n 4-INCH SENSUS OMNI C2 WATER 12" SPOOL METER a PIECE n ISOLATION VALVE SLOPE FL,OQR, TO DRAIN 1 4':1 6 °AANILJnl C CTCnC' SECTION A PLAN FIRE LINE INSIDE PIT DIMENSIONS ACCESS DOOR LENGTH WIDTH DEPTH SIZE SIZE 6 INCH 8'-0" 6'-0" 6'-6" DOUBLE LEAF " 4'- 0 x 4'-0" 8 INCH 8-0" 6'-0" 7'-0" DOUBLE LEAF 5 -0" x 5'-0" 10 INCH 8'-0" 8'-0" 7'-0" DOUBLE LEAF 4 -0" x 6'-0" PRECAST CONCRETE VAULT (WITH APPROVAL) 3/4" STAINLESS STEEL ALL THREADED ROD 24"X24"X1/2" STEEL PLATE C ISOLATION VALVE 6" DRAIN TO DAYLIGHT 6" #57 WASHED STONE /2" LATE FLOW A GROUT PIPE IN OVERSIZED OPENING. NO CONTACT BETWEEN PIPE AND CONCRETE (TYPICAL) 'VC DRAIN PIPE. _....... ...__. __ ... ED TO DAYLIGHT @ MIN. 1% SLOPE. D6.12 COMBINATION DOMESTIC AND FIRE METER AND VAULT NOT TO SCALE UTILITY DETAILS 0 U N LO V � 0 LO l() O v 0 � N N 6 aO (0 N � U 00 U o 00 tA � N I--�--�i %0 U .� 3Nz C 0 _ C m �> 0 Q N Ua.4 'EAR _R� ma 4 2 G�Ux a WW a�z,x a m. 0 °a w N>nna F W� LL J"a w3 O Q d CL v 2 > (5 O a UaU 3 w z U m This drawing is the property of Cope Associates, Inc and is not to be reproduced without prior written authorization. This drawing is intended to be used only for the project and site specifically identified. All design information are the copyright of Cope Associates Inc. @ 2020 REVISIONS NO. DATE DESCRIPTION 0 11 /04/22 ISSUED FOR BID 1 12/09/22 ADDENDUM 3 DATE: 12/2/2022 DRAWN BY: JCP II111�� 00 =Qa� -vain a� _Z°_= UW= %y°oCJ ff DWG NO. C961 PROJECT NO. 12208 FULL SHEET SIZE: 36"X48" GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH THE NCG01 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCG01 Construction General Permit (Sections E and F, respectively). The permittee shaft comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. SECTION E: GROUND STABILIZATION Required Ground Stabilization Timeframes Stabilize within this Site Area Description many calendar Timeframe variations days after ceasing land disturbance (a) Perimeter dikes, swales, ditches, and 7 None perimeter slopes (b) High Quality Water 7 None (HOW) Zones (c) Slopes steeper than If slopes are 10' ar less in length and are 3:1 7 not steeper than 2:1, 14 days are allowed -7 days for slopes greater than 50' in length and with slopes steeper than 4:1 -7 days for perimeter dikes, swales, (d) Slopes 3:1 to 4 1 14 ditches, perimeter slopes and HQW Zones -10 days for Fails Lake Watershed -7 days for perimeter dikes, swales, {e} Areas with slopes ditches, perimeter slopes and HQW Zones flatter than 4:1 14 -10 days for Falls Lake Watershed unless there is zero slope Note: After the permanent cessation of construction activities, any areas with temporary ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last land disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below: Temporary 5tabflfzation ■ Temporary grass seed covered with straw or other mulches and tack ifiers • Hydfoseeding • Rolled erosion control products with a without temporary grass seed • Appropriately applied straw or other mulch ■ Plastic sheeting Permanent subiilzation • Permanent grass seed covered with straw or other mulches and tackifiers • Geotextile fabrics such as permanent soil reinforcement matting • Hydroseeding • Shrubs or other permanent plantings covered with mulch . L)nifor rn and evenly distributed ground cover sufficient to restrain erosion ■ Structural methods such as concrete, asphalt or retaining walls • Rolled erosion control products with grass seed POLYACRYLAMIDES [PAMSj AND FLOCCULANTS 1. Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC A WR List of Approved PAMS/Rocculants. 2. Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3. Apply flocculants at the concentrations specified in the NC DWR List of Approved DAMS/Flocculonts and in accordance with the manufacturer's instructions. 4. Provide ponding area for containment of treated Stormw offs]te. 5. Store flocculants in leak -proof containers that are kept u or surrounded by secondary containment structures_ a NCG01 EQUIPMENT AND VEHICLE MAINTENANCE 1. Maintain vehicles and equipment to prevent discharge of fluids, 2. Provide drip pans under any stored equipment. 3. Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4. Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible), 5. Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6. Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1. Never bury or burn waste. Place litter and debris in approved waste containers. 2. Provide a sufficient number and size of waste containers (e.g dumpster, trash receptacle) on site to contain construction and domestic wastes. 3. Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available, 4. Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5. Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers. 6. Anchor all lightweight items in waste containers during times of high winds. 7. Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow. 8. Dispose waste off -site at an approved disposal facility. 9. On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1. Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2. Locate paint washouts at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3. Contain liquid wastes in a controlled area. 4. Containment must be labeled, sized and placed appropriately for the needs of site. 5. Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1. Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available, if 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2. Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas. 3. Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit. EARTHEN STOCKPILE MANAGEMENT ONSITE CONCRETE WASHOUT STRUCTURE WITH f_INER On ��mrtio ilE ■ �'• � � c c�aoww�c ra v n• rrrrcn..o u�.'i 'fir 'fit rvr"rti' ado a �I anmr r.e,A»r JRCTrBE Aar GRAJ 4isWrr 12T9IrTJ CIE CONCRETE WASHOUTS 1. Do not discharge concrete or cement slurry from the site. 2. Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility. 3. Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence. 4. Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product Is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail. 5. Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6. Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain Inlet(s) closest to the washout which could receive spills or overflow. 7. Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout. Additional controls may be required by the approving authority, 8. Install at least one sign directing concrete trucks to the washout within the project limits. Post signage on the washout itself to identify this location. 9. Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp, sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary products, follow manufacturer's instructions. 10. At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance caused by removal of washout. HERBICIDES, PESTICIDES AND RODENTICIOES 1. Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2. Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning. 3. Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4. Do not stockpile these materials onsite. HAIARDOUS AND TOXIC WASTE 1. Create designated hazardous waste collection areas on -site. ter before discharging 2. Place hazardous waste containers under cover or in secondary containment. VIP,`' NORTH CAROLINA 3. Do not store hazardous chemicals, drums or bagged gg materials directly on the ground. nderitorm-resistant cover 4ke} Environmental Quality GROUND STABILIZATION AND MATERIALS HANDLING PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION A: SELF -INSPECTION Self -inspections are required during normal business hours in accordance with the table below. When adverse weather or site conditions would cause the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which it is safe to perform the inspection. In addition, when a storm event of equal to or greater than 1.0 inch occurs outside of normal business hours, the self -inspection shall be performed upon the commencement of the next business day. Any time when inspections were delayed shall be noted in the Inspection Record. Frequency Inspect (during normal InspenF'san records me ust includ business hours) (1) Rain gauge daily Gaily rainfall amounts. maintained in It no daily rain gauge nhservatinns are made during wP.ek end nr goad woncin; holiday periods, and no individual day rainfall information :s arcier available, record the cumulative rain measurement for those un- attended days (anc this will determine if a site inspection is needed). O?iys on which no rainfall occurred shall he mcnrded as "zero." The permittee may use another rain -monitoring device approved by the Division.. [2] E&SC At (cast once per I. ldcntification of the measures inspected, Measures 7 calendar days 2. pate and time of the inspection, and within 24 3. Name of the perscn performing the Inspection, hours of a rain 4. indlcatfon of whether the measures were operating event 5 1.4 Inch In properly, 24 hours 5. F7escriptfan of malntenan[e needs for the measure, 6. pesr,riptinn, evidence., and date of rnrmitive aClans taken. [3] Stnrmwa:er At least once per I. Identification of the dischargn nutfalls inspected, discharge 7 calendar days 2. pate and time of Y.he inspertinn, autFalls (SOGs) and within 24 3. Name of the perscn performing the inspection, hours of a rain 4. Evidence of indicators of stormwater pollution such as oil event? 1.4lnch In sheen, floating or suspended solids or discoloration, 24 hours 5. Indlcatinn of visible sediment leaving the site, 6. Description, evidence, and date of corrective actions taken. [4] PeYSmeter of At least once per If visible sedimentation isfound outside site lirnirs, then a recorri site 7 calendar days of the fallowing shall be made: and within 24 t. Actions taken to clean up or stabilize the sediment that has left hours of a rain the site limits, event a 1.0inch In 2. bescription, evidence, and date of corrective actions taken, and 24 hours 3. An explanation as to the actions taken to control future releases. (S) Streams or At least once per If the stream or wetland has increased visible sedimentation ar a wetlands onsite 7 calendar days stream has visible increased turbidity from the construction or off'site and within 24 activity, then a record of the following shall be made' [where hours of a rain 1. nescription, evidence and date of cnrrcrtivc acl.inns taken, and actes5ihlcl Event > 3.0 inch in 2. Rnrnrds of the required reports to the appropriate i7ivisinn 24 hours Regional Office per Part III, Section C, Item [2](af of this permir. 16) Ground Aftnr oarh phase 1. The phase of grating (fnstallatEnn of perimeter E&SC stabilization of grading measures, clearing and grubbing, installation of storm measures drainage #acilities, completion of all land -disturbing activity, construction or redevelopment, permanent ground mver). 2. Oncumentatinn that the required ground stabilization measures have been provided within the required timcframc or an assurance that they will be provided as soon as passible. 1. Show stockpile locations on plans. Locate earthen -material stockpile areas at least 50 feet away from storm drain inlets, sediment basins, perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available. 2. Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3. Provide stable stone access point when feasible. 4. Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs. PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION B: RECORDKEEPING 1. E&SC Plan Documentation The approved E&SC plan as well as any approved deviation shall be kept on the site. The approved E&SC plan must be kept up-to-date throughout the coverage under this permit. The following items pertaining to the E&SC plan shall be kept on site and available for inspection at all times during normal business hours. Item to Document Documentation Requirements (a) Each E&SC measure has been installed Initial and date each E&SC measure on a copy and does not significantly deviate from the of the approved E&SC plan or complete, date locations, dimensions and relative elevations and sign an inspection report that lists each shown on the approved E&SC plan. E&SC measure shown on the approved E&SC plan. This documentation is required upon The initial installation of the E&SC measures or if the E&SC measures are modified after initial installation. (b) A phase of grading has been completed. Initial and date a copy of the approved E&SC plan or complete, date and sign an inspection report to indicate completion of the construction phase. (c) Ground cover is located and installed Initial and date a copy of the approved E&SC in accordance with the approved E&SC plan or complete, date and sign an inspection plan. re port to Indicate compliance with approved grc u nd cover specifications. (d) The maintenance and repair Complete, date and sign an inspection report. requirements for all E&SC measures have been performed. (e) Corrective actions have been taken Initial and date a copy of the approved E&SC to E&SC measures. plan or complete, date and sign an inspection report to indicate the completion of the corrective action. 2. Additional Documentation to be Kept on Stte In addition to the E&SC plan documents above, the following items shall be kept on the site and available for inspectors at all times during normal business hours, unless the Division provides a site -specific exemption based on unique site conditions that make this requirement not practical: (a) This General Permit as well as the Certificate of Coverage, after it is received. (b) Records of inspections made during the previous twelve months. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically -available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard -copy records. 3. Documentation to be Retained for Three Years All data used to complete the a-NOI and all inspection records shall be maintained for a period of three years after project completion and made available upon request [40 CFR 122.411 PART II, SECTION G, ITEM (4) DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT Sediment basins and traps that receive runoff from drainage areas of one acre or more shall use outlet structures that withdraw water from the surface when these devices need to be drawn down for maintenance or close out unless this is infeasible. The circumstances in which it is not feasible to withdraw water from the surface shall be rare (for example, times with extended cold weather). Non -surface withdrawals from sediment basins shall be allowed only when all of the following criteria have been met: (a) The E&SC plan authority has been provided with documentation of the non -surface withdrawal and the specific time periods or conditions in which it will occur. The non -surface withdrawal shall not commence until the E&SC plan authority has approved these items, (b) The non -surface withdrawal has been reported as an anticipated bypass in accordance with Part III, Section C, Item (2)(c) and (d) of this permit, (c) Dewatering discharges are treated with controls to minimize discharges of pollutants from stormwater that is removed from the sediment basin. Examples of appropriate controls include properly sited, designed and maintained dewatering tanks, weir tanks, and filtration systems, (d) Vegetated, upland areas of the sites or a properly designed stone pad is used to the extent feasible at the outlet of the dewatering treatment devices described in Item (c) above, (e) Velocity dissipation devices such as check dams, sediment traps, and riprap are provided at the discharge points of all dewatering devices, and (f) Sediment removed from the dewatering treatment devices described in Item (c) above is disposed of 1n a manner that does not cause deposition of sediment into waters of the United States. EFFECTIVE: 04/01 / 191 PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1. Occurrences that Must be Reported Permittees shall report the following occurrences: (a) Visible sediment deposition in a stream or wetland. (b) Oil spills if: ■ They are 25 gallons or more, ■ They are less than 25 gallons but cannot be cleaned up within 24 hours, They cause sheen on surface waters (regardless of volume), or They are within 100 feet of surface waters (regardless of volume). (c) Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S.143-215.85. (d) Anticipated bypasses and unanticipated bypasses. (e) Noncompliance with the conditions of this permit that may endanger health or the environment. 2. Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Department's Environmental Emergency Center personnel at (8010) 858-0368. Occurrence Reporting Timeframes (After Discovery) and Other Requirements (a) Visible sediment ■ Within 24 hours, an oral or electronic notification. deposition in a . Within 7 ealendar days, a report that contains n description of the stream or wetland sediment and actions taken to address the cause of the deposition. Division staff may waive the requirement for a written report on a case -by -case basis. • If the stream is named on the NC 303(d) list as impaired for sediment - related causes, the permittee may be required to perform additional monitoring, inspections or apply more stringent practices if staff determine that additional requirements are needed to assure compliance with the federal or state impaired -waters conditions. (b) 011 spills and ■ Within 24 hours, an oral or electronic notification. The notification release of shall include information about the date, time, nature, volume and hazardous location of the spill er release. substances per Item 1(b)-(c) above (c) Anticipated ■ A report at least ten days before -the date of the bypass, ifpassible. bypasses [40 CFR The report shall include an evaluation of the anticipated quality and 122.41(m)(3)] effect of the bypass. (d) Unanticipated ■ Within 24 hours, an oral or electronic notification. bypasses [40 CFR ■ WltNn 7 cafendardays, a report that includes an evaluation of the 122.41(m)(3)] quaIItyand effect of the bypass. (e) Noncompliance • Within 24 hours, an oral or electronic notification. wlth the conditions ■ Within 7 calendar days, a report that contains a description of the of this permit that noncompiiance, and its causes; the period of noncompliance, may endanger including exact dates and times, and if the noncompliance has not health or the been corrected, the anticipated time noncompliance is expected to envtronment[40 continue; and steps taken or planned to reduce, eliminate, and CFR 122.41(1)(7)] prevent reoccurrence of the noncompliance. [40 CFR 122.41(I)(6). ■ Division staff may waive the requirement for a written report on a case -by -case basis. t NORTH CAROUNA Environmental Qualit3 NCGO1 SELF -INSPECTION, RECORDKEEPING AND REPORTING I EFFECTIVE: 04/01/19I J 0 0 2 U Z O U J J W 2 U H J O O U U/ W J 0 0 w L�� SEAR _R� U. a=Z m .0 as L U N = n a tu�� 6 w M z Ln 0 �00 N N N Q Z Q J � 0 S n_ CD Q S U z� 0 �z �w 0 Cn J Ln > COCn C) Of Ln u -I Y Q m E 0 U 2 o a0i o2 o!E rn 2 v ro rn 0 Q uO 0 r9 U 00 W U N N rA vi }a c ° _ '7 0 N O to Q hie Q) .; CL ,0 r- O UN�k E 0 U N V lLO LO-O v � N 0 N 'o; rA M N U co co 2 rA U t U o 00 tA CO 'a C4 f� V 3IZ LU >C - C O m oON U a 4 This drawing is the property of Cope Associates, Inc and is not to be reproduced without prior written authorization. This drawing is intended to be used only for the project and site specifically identified. All design information are the copyright of Cope Associates Inc. © 2020 REVISIONS NO. I DATE I DESCRIPTION 0 1 11 /04/22 ISSUED FOR BID 1 112/09/221 ADDENDUM 3 DATE: DRAWN BY: 12/2/2022 _J00 - U ua U - W U) LLJ _J �° = y°od CD NCGO1 JCP DWG NO. C998 PROJECT NO. 12208 FULL SHEET SIZE: 36"X48"