Loading...
HomeMy WebLinkAboutNC0060461_Permit Issuance_20120328NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor Mr. Martin Lashua, Regional Director Caroiina Water Service, inc. of NC PO Box 240908 Charlotte, North Carolina 28224 Dear Mr. Lashua: Division of Water Quality Charles Wakilcl, P.F flee Freeman Director Secretary March 28, 2012 Subject: Issuance of NPDES Permit No. NCO060461 Abington Subdivision WWTP — Class WW2 Forsyth County Division personnel have reviewed and approved your application for renewal of the subject permit. Accordingly, we are forwarding the attached NPDES discharge permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). The following modifications in the December 8, 2010 draft permit remain in the final permit: • Footnote #1 has been added with the following additional Total Residual Chlorine Language: "The facility shall report all effluent TRC values reported by a NC certified laboratory including field certified. However, effluent values below 50 ug/I will be treated as zero for compliance purposes." • Footnotes have been modified and added. • The site map has been updated to reflect lat & long values for your discharge point. If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150E of the North Carolina General Statutes, and filed with the Office of Administrative Hearings (6714 Mail Service Center, Raleigh, North Carolina 27699-6714). Unless such demand is made, this decision shall be final and binding. Please note that this permit is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the permit. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, the Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Bob Guerra at telephone number (919) 807-6387 or email at (bob.guerra(a)ncdenr.gov). Director Enclosure: NPDES Permit NCO060461 11 41� Wakild, P.E. cc: Winston-Salem Regional Office /Surface Water Protection corey.basingera(D.ncdenr.gov) (ecopy) NPDES Unit Central Files 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 One 1 Phone: 919-807-6387 \ FAX: 919-807-6495 \ Customer Service: 1-877.623-6748 1� oi�thCarolini Internet: www.ncwaterquality.org �'f� �C��y�� //, / An Equal Opportunity 1 Affirmative Action Employer i/ y ` ` 11 Permit NCO060461 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER Q! 'ALITY TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM. In compliance with the provisions of North -Carolina* General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Carolina Water Service, Inc. of NC is hereby authorized to discharge wastewater from a facility located at the Abington Subdivision WWTP 6890 Bainburg Court Forsyth County to receiving waters designated as Belews Creek in the Roanoke River Basin in accordance with effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This permit shall become effective. May 1, 2012. This permit and authorization to discharge shall expire at midnight on February 28, 2017. Signed this day March 28, 2012. Cha a akild, P.E., Director Di on of Water Quality By Authority of the Environmental Management Commission Permit NC006046i SUPPLEMENT TO PERMIT COVER SHEET All previous NPDES Permits issued to this facility; whether for operation or discharge are hereby revoked. As of this permit issuance, any previously issued permit bearing this number is no longer effective. Therefore, the exclusive authority to operate and discharge from this facility arises under the permit conditions, requirements; terms, and provisions included herein. Carolina Water. Service, Inc. of NC is hereby authorized to: 1. Continue to operate an existing 0.200 MGD extended aeration wastewater treatment plant with the following components: ♦ Equalization basin with dual pumps ♦ Bar screen 4 Flow splitter box ♦ Dual aeration basins ♦ Dual clarifiers ♦ Tablet chlorinators ♦ Chlorine contact tank ♦ Dechlorination unit with tablet dechlorination ♦ Post aeration chamber ♦ Aerobic sludge holding digester ♦ Float analog graph flow meter ♦ Stand-by emergency generator The facility is located north of Kernersville in the Abington Subdivision, 6890 Bainburg Court in Forsyth County. 2. After receiving an Authorization to Construct from the Division of Water Quality, construct additional facilities for a.total treatment capacity not to exceed 0.385 MGD, and 3. Discharge from said treatment works at the location specified on the attached map into Belews Creek, classified C waters in the Roanoke River Basin. Carolina Water Service, Inc of NC Abington Subdivision WWTP Latitude: 360 10' 3" State Grid: Belews Creek Longitude: 800 o6' 18" Permitted flow: 0.200 / 0.385 MGD Receiving Stream: Belews Creek Drainage Basin: Roanoke River Stream Class: C Sub -Basin: 03-02-01 Facility Location not to scale TOY'tj2 NPDES Permit No. NCO060461 Forsyth County Permit NCO060461 A. (1.) EFFLUENT LIMITS AND MONITORING REQUIREMENTS During the period beginning on the effective day of this permit and lasting until expansion above 0.2 MGD or February 28, 2017, the permittee is authorized to discharge treated wastewater from outfall 001. Such discharges shall be limited and monitored by the permittee as specified below: , MONITORI ,Q,REQUIREMENT8, EFFLUENT,CHARACTERISTIGS, „r, ,,. , EFFLUENT;LIMITS, ,n ,a Monthly Datly Measurement SSample Sample r Average Maximum Frequency Type Location R`� > a 50050 - Flow 0.2 MGD Continuous Recorder I or E Daily -- 00010 - Temperature, Water (deg. C) weekdays Grab E 50060 - Chlorine, Total Residual2 28 pg/L 2 / week Grab E 00400 - pH (s.u.) Weekly Grab E 00010 - Temperature, Water (deg. C) Weekly Grab U & D 00300 - DO, Oxygen, Dissolved (mg/L) Weekly Grab U & D 00310 - BOD, 5-Day 30.0 mg/L 45.0 mg/L Weekly Composite E 00530 - Total Suspended Solids 30.0 mg/L 45.0 mg/L Weekly Composite E 00610 - Nitrogen, Ammonia Total (as N) 2.0 mg/L 10.0 mg/L Weekly Composite E (April 1 - October 31) 00610 - Nitrogen, Ammonia Total (as N) 4.0 mg/L 20.0 mg/L Weekly Composite E (November 1 - March 31) 31616 - Coliform, Fecal MF, M-FC 200#/100ml 400#/100ml Weekly Grab E Broth,44.5C (geom.mean) 00300 - DO, Oxygen, Dissolved (mg/L) Weekly Grab E 00665 - Phosphorus, Total (as P) (mg/L) . Quarterly Composite E 00600 - Nitrogen, Total (as N) (mg/L) Quarterly Composite E Footnotes: 1. I = Influent, E = Effluent, U =Upstream: at least 100 feet above the outfall; D = Downstream: at NCSR 2014. 2. The facility shall report all effluent TRC values reported by a NC certified laboratory including field certified. However, effluent values below 50 ug/I will be treated as zero for compliance purposes. 3. The pH shall not be less than 6.0 standard units (s.u.) nor greater than 9.0 s.u. 4. The daily average Dissolved Oxygen effluent concentration shall not be less than 5.0 mg/L. There shall be no discharge of floating solids or visible foam in other than trace amounts Permit NCO060461 A. (2.) EFFLUENT LIMITS AND MONITORING REQUIREMENTS During the period beginning upon expansion to 0.385 MGD and iasting untii February 28, 2017, the permittee is authorized to discharge treated wastewater from outfall 001. Such discharges shall be limited and monitored by the permittee as specified below: EFFLUEWT','CHARACTERISTICS�, EFFLUEfVTLIMITS„ ,,.,,» , , y. , .MONITORINGtREQUIREMENTS „ yr °' Monthly ` - Daily,` Measurement ' Samp fe Sample ," F; i ff t Average in -Frequency Ty�P Ii�Gaflon' 50050 - Flow 0.385 MGD Continuous Recorder I or E 00010 -Temperature, Water (deg. C) Daily -- Grab E weekdays 50060 - Chlorine, Total Residua12 25 pg/L 2 / week Grab E 00400 - pH3 (s.u.) Weekly Grab E 00010 - Temperature, Water (deg. C) Weekly Grab U & D 00300 - DO, Oxygen, Dissolved (mg/L) Weekly Grab U & D 00310 - BOD, 5-Day 30.0 mg/L 45.0 mg/L Weekly Composite E 00530 - Total Suspended Solids 30.0 mg/L 45.0.mg/L Weekly Composite E 00610 - Nitrogen, Ammonia Total (as N) 2.0 mg/L 10.0 mg/L Weekly Composite E (April 1 - October 31) 00610 - Nitrogen, Ammonia Total (as N) 4.0 mg/L 20.0 mg/L Weekly Composite E (November 1 - March 31) 31616 - Coliform, Fecal MF, M-FC 200#/100ml 400#/100ml Weekly Grab E Broth,44.5C (geom.mean) 00300 - DO, Oxygen, Dissolved (mg/L) Weekly Grab E 00665 - Phosphorus, Total (as P) (mg/L) Quarterly Composite E 00600 - Nitrogen, Total (as N) (mg/L) Quarterly Composite E Footnotes: 1. I = Influent, E = Effluent, U =Upstream: at least 100 feet above the outfall; D = Downstream: at NCSR 2014. 2. The facility shall report all effluent TRC values reported by a NC certified laboratory including field certified. However, effluent values below 50 ug/I will be treated as zero for compliance purposes. 3. The pH shall not be less than 6.0 standard units (s.u.) nor greater than 9.0 s.u. 4. The daily average Dissolved Oxygen effluent concentration shall not be less than 5.0 mg/L. There shall be no discharge of floating solids or visible foam in other than trace amounts a x" , Guerra, Bob From: Martin Lashua [MJ Lash u a@u iwater.com] Sent: Thursday, January 05, 2012 4:55 PM To: Guerra, Bob Cc: Mary Rollins; Tony Konsul Subject: Abington Wastewater Treatment Plant - Forsyth County - Draft - Permit NCO060461 Mr. Guerra, We are in receipt of the 12/8/11 draft permit for the above referenced facility and have no comments. Thank you for your attention. Regional Director Phone 704-319-0517 email milash uana.0Water. com Winston-Salem Journal Advertising Affidavit Winston-Salem Journal P.O Box 3159 Winston-Salem, NC 27102 NCDENR/DWQ/POINT SOURCE BRANCH ATTN: DINA SPRINKLE 1617 MAIL SERVICE CENTER RALEIGH, NC 27699-1617 Account Number 3376309 Date -1 December 13, 2011 Date Category Description Ad Size Total Cost 12/13/2011 Legal Notices PUBLIC NOTICE North Carolina Environmental Management Commission/NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Notice of Intent to Issue a NPDES Wastewater Permit The North Carolina Environmental Management Commission proposes to issue a NPDES wastewa- ter discharge permit to the person(s) listed below. Written comments regardingg the proposed permit will be accepted until ,30 days after the publish date of this notice. The Director of the NC Division of Water Quality (DWQ) may hold a public hearing should there be a significant degree of public in- terest. Please mail comments and/or information requests to DWQ at the above address. Interested persons may visit the DWQ at 512 N. Salisbury Street, Raleigh, NC to review information on file. Additional information on NPDES permits and this notice may be found on our website: http://portal ncdenr.org/web/wq/swp/ps/npdes/calendar, or by calling (919) 807-6304. Stokes County Schools requested renewal of per- mit NC0087980/Pine Hall Elementary School WWTP. Facility discharges to Eurins Creek/ Roa- noke River Basin. Currently, fecal coliform is wa- ter quality limited. Stokes County Schools requested renewal of per- mit NC0044962/North Stokes High School WWTP. Facility discharges treated wastewater to an un- named tributary to the Dan River/Roanoke River Basin. Currently, total residual chlorine and fecal coliform are water quality limited. Stokes County Schools requested renewal of NPDES permit NC0044954/South Stokes High School WWTP. Facility discharges to Little Neat - man Creek/Roanoke River Basin. Currently, fecal coliform and total residual chlorine are water quality limited. City of Winston-Salem, Forsyth County, has ap- plied to renew permit NCO086762 for PW Swain WTP, River Ridge Road, discharging filter -back- wash to UT Bashavia Creek, Yadkin River Basin. Carolina Water Service, Inc. NC requested renewal of permit NCO060461 for Abington Subdivision WWTP In Forsyth County; this permitted discharge is treated domestic wastewater to Belews Creek, Roanoke River Basin. Horizons Residential Care Center applied for re- newal of NPDES permit NCO056791 for the Hori- zons Residential Care Center WWTP in Forsyth County; this permitted discharge is treated do- mestic wastewater to Buffalo Creek in the Roa- noke River Basin. Allegiance Healthcare Investors, LLC requested re- newal of permit NC0037311/Creekside Manor Rest Home/Forsyth County. Facility discharges to an +unnamed tributary to Belews Creek/Roanoke River Basin. Currently dissolved oxygen, ammonia nitrogen, fecal coliform and total residual chlorine are water quality limited. PUBLIC NOTICE North Carolina Environmental Managem 1 x 75 L 543.00 Media General Operations, Inc. Publisher of the Winston-Salem Journal Forsyth County Before the undersigned, a Notary Public of Forsyth County, North Carolina, duly commissioned, qualified, and authorized by law to administer oaths, personally appeared S. A. Bragman, who by being duly sworn deposes and says: that she is the Assistant Controller of the Winston-Salem Journal, engaged in the publishing of a newspaper known as Winston-Salem Journal, published, issued and entered as second class mail in the City of Winston-Salem, in said County and State: that she is authorized to make this affidavit and sworn statement: that the notice or other legal advertisement, a true copy of which is attached hereto, was published in the Winston-Salem Journal on the following dates: 12/13/2011 and that the said newspaper in which such notice, paper document, or legal advertisement was published was, at the time of each and every such publication, a newspaper meeting all the requirements and qualifications of Section 1-597 of the General Statutes of North Carolina and was a qualified newspaper within the meaning of Section 1-597 of the General Statutes of North Carolina. This 13th day of December, 2011 V__ (signature ofp f on making affidavit) Sworn to and subscribed before me, this 13th day of December, 2011 KI ALEY JOHNSON NOTARY PUBLIC My Commission expires Z� ZQ 1 FORSYTH COUNTY STATE OF NORTH CARQLIU, My COMMISSION EXPIRE THIS IS NOT A BILL. PLEASE PAY FROM INVOICE. THANK YOU FACT SHEET COMPLEX EXPEDITED - PERMIT RENEWAL Permit Writer/Date Bob Guerra / 2-28-12 Permit Number NCO060461 Facility Name Carolina Water Service, Inc of NC - Abington WWTP Class WW 2 Basin Name/Sub-basin number Roanoke River / 03-02-01 Receiving Stream Belews Creek Stream Classification in Permit C Does permit need Daily Max NH3 limits? No — already in permit Does permit need TRC limits/language? Yes — added to permit Does permit have toxicity testing? No Does permit have Special Conditions? No Does permit have instream monitoring? Yes — Review shows no impacts Is the stream impaired on 303 d list)? No Any obvious com liance'concerns? No Any permit mods since lastpermit? No Current expiration date February 28, 2012 New expiration date February 28, 2017 Comments received on Draft Permit? None Renewal Review and BIMS Downloads / Changes for Renewal: • DMR Report Violations 0 4 (four) enforcement actions during existing permit cycle ■ LV-2007-0274, Iv-2010-0221, LV-2010-0261 & LV-2010-0391 • Permit Changes: 0 Footnote #1 has been added with the following additional Total Residual Chlorine Language: "The facility shall report all effluent TRC values reported by a NC certified laboratory including field certified. However, effluent values below 50 ug/I will be treated as zero for compliance purposes. 0 "Footnotes have been modified and added. 0 The site map has been updated to reflect lat & long values for your discharge point • BIMS pull Effluent Parameter .o Dally avg Monthly avg o a BOD 34.67 mg/I 12.21 mg/L DO 7.71 mg/L 6.52 mg/L FECAL 66.12 #/100ml 9.05 / #100 ml FLOW 0.23 MGD 0.127 mgd NH3 2.25 mg/L 0.100 mg/L PH 7.35 s.u. 7.05 s.u. TEMP 24.90 19.10 deg c TRC 32.20 ug/L 18.10 ug/L TSs 10.26 mg/L 32.27 mg/L UtilitiEs, lnc.'� August 30, 2011 Mrs. Dina Sprinkle NC DENR Division of Water Quality Point Source Branch 1617 Mail Service Center Raleigh NC 27699-1617 Re: Abington WWTP NPDES NCO060641 Renewal Request Dear Mrs. Sprinkle, Please find the enclosed application and attachments and consider this letter as our official request to renew the NPDES permit for the facility referenced above. If you should have any questions or need any additional information, please do not hesitate to call me at 704-319-0517 or by email at milashuaCcDuiwater.com Thank you in advance for your attention. Sinc rely, Martin Lashua ED Regional Director FS E-P 0 1 2911 POI autil&s,Inc. cmpmyCarolina Water Service, Inc. of North Carolina P.O. Box 240908 • Charlotte, NC 28224 0 P: 704-525-7990 0 F: 704-525-8174 5701 Westpark Dr., Suite 101 i Charlotte, NC 28217 i www.uiwater.com NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD Mail the complete application to: N. C. Department of Environment and Natural Resources Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit NCO060461 If you are completing this form in computer use the TAB key or the up - down arrows to moue from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name Carolina Water Service, Inc of NC Facility Name Abington - WWTP Mailing Address P.O. Box 240908 City Charlotte State / Zip Code NC, 28224 Telephone Number (704)319-0517 Fax Number (704)525-8174 e-mail Address mjlashua@uiwater.com 2. Location of facility producing discharge: Check here if same address as above ❑ Street Address or State Road 6890 Bainburg Court City Kernersville State / Zip Code NC, 27284 County Forsyth 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Same as owner above Mailing Address _ City State / Zip Code Telephone Number Fax Number 1 of 3 Form-D 1/06 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 4. Description of wastewater: Facility Generating Wastewater(check all that apply): Industrial ❑ Number of Employees 1 Commercial ❑ Number of Employees Residential ® Number of Homes 662 School ❑ Number of Students/Staff Other ❑ Explain: Describe the source(s) of wastewater (example: subdivision, mobile home park, shopping centers, restaurants, etc.): Queens Harbor - Subdivision 662 x 2.5 = 1655 population Population served: 1655 5. Type of collection system ® Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points 1 Outfall Identification number(s) 001 Is the outfall equipped with a diffuser? ❑ Yes ® No 7. Name of receiving stream(s) (Provide a map showing the exact location of each outfall): Belews Creek 8. Frequency of Discharge: ® Continuous ❑ Intermittent If intermittent: Days per week discharge occurs: Duration: 9. Describe the treatment system List all installed components, including capacity, provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet of paper. The .02 MGD treatment facility consists of the following components; Bar screen, flow splitter box, equalization basin, dual clarifiers, dual aeration basins , chlorine contact basin, tablet chlorine disinfection, tablet de -chlorination, aerobic digester, post aeration chamber, effluent flow measurement, standby generator with automatic transfer switch. 10. Flow Information: Treatment Plant Design flow 0.2 MGD Annual Average daily flow .1291 MGD (for the previous 3 years) Maximum daily flow .4260 MGD (for the previous 3 years) 2 of 3 Form-D 1/06 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 11. Is this facility located on Indian country? ❑ Yes ® No 12. Effluent Data Provide data for the parameters listed. Fecal Coliform, Temperature and pH shall be grab samples, for all other parameters 24-hour composite sampling shall be used. Effluent testing data must be based on at least three samples and must be no more than four and one half years old. Parameter Daily Maximum Monthly Average Units of Measurement Number of Samples Biochemical Oxygen Demand (BOD5) 3.85 3.01 mg/L (4) -Jan 11 Fecal Coliform 7 2.5 #/ 100ml (4) - Jan 11 Total Suspended Solids <1.0 0.0 mg/L (4) - Jan 11 Temperature (Summer) 23.8 22.7 Celcius (4) -June 11 Temperature (Winter) 13.4 11.8 Celcius (4) -Jan 11 PH 7.07 6.86 units (12)- Jan 11 13. List all permits, construction approvals and/or applications: Type Permit Number Type Hazardous Waste (RCRA) UIC (SDWA) NPDES NCO060461 PSD (CAA) Non -attainment program (CAA) 14. APPLICANT CERTIFICATION NESHAPS (CAA) Ocean Dumping (MPRSA) Dredge or fill (Section 404 or CWA) Special Order of Consent (SOC) Other Permit Number WQCS00261 I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Martin Lashua Regional Director Printed namq)of Perlon Signing n Title Signature of Applicant Date North Carolina General Statute 143-215.6 (b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) 3 of 3 Form-D 1/06 UtilitiEs, Inc August 30, 2011 Mrs. Dina Sprinkle NC DENR Division of Water Quality Point Source Branch 1617 Mail Service Center Raleigh NC 27699-1617 Re: Abington WWTP NPDES NCO060641 Sludge Management Plan Dear Mrs. Sprinkle, As sludge and other solids are generated at this facility, they are periodically removed by one of the two licensed contractors listed below; Carolina Septic 141 Furlong Industrial Drive Kernersville, NC 27284 Phone: 336-993-5633 -AND/OR- Republic Services, Inc P.O. Box 219 Pineville, NC 28134 Phone: 704-393-6900 If you should have any questions or need any additional information, please do not hesitate to call me at 704-319-0517 or by email at mjlashua@uiwater.com Thank you in advance for your attention. Sin r ly, z LL Martin Lashua Regional Director a utiiit�s, Inc. c«„ panyCarolina Water Service, Inc. of North Carolina P.O. Box 240908 0 Charlotte, NC 28224 0 P: 704-525-7990 • F: 704-525-8174 5701 Westpark Dr., Suite 101 o Charlotte, NC 28217 0 www.uiwater.com Abington WWTP Pictures: TCS-WS-140 Pic . # Description 1. Influent Pump Station Wet Well— 2, 25 Hp submersible pumps 2. Splitter Box / Manual Bar Screen 3. EQ Basin 4. Aeration Basin 5. Aeration Basin . 6. Clarifier 7. Clarifier 8. Digesters 9. Digesters 10. Tablet Chlorinators 11. Tablet Dechlorinators 12. Chlorine Contact Basin 13. Storage Building 14. 2-40 Hp Blowers pao 00 'WA 10-7 2011 3•. 4 Tax Certification Inspection Report Determination Facility: ....................................... Carolina Water Service Inc. (Abington WWTP) Tax Certification Number: .................. TCS-WS-140 Inspection Date: .............................. ALL ITEMS LISTED QUALIFY FOR TAX CERTIFICATION: Yes ff, No ❑ 1. Abington Wastewater Treatment Plant Qualifies? Yes ® No El O,0&0 M G D 55 e CAsc.-S Ps �s kA ? p Sa n ��ob UZ-VW-S 10) [55 0 File name: Abington wWTP Insp-Report.doo Date printed: September 1, 2010 Page No. 1 of 1 o can �JaAITV