Loading...
HomeMy WebLinkAboutNC0060461_Authorization to Construct_20141103�4 ? Des F1 L NlCvJ(oo4-U( Carolina Water Services, Inc. of NC Abington Subdivision WWTP Authorization to Construct No. 060461 AO Issued May 9, 2014 Engineer's Certification 1, William G. Langley , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the modifications and improvements to the Abington Subdivision Wastewater Treatment Plant, located in Forsyth County, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the following construction: Installation of a new liquid chlorination system consisting of two (2) 24 GPD chemical feed pumps in an induced suction arrangement from a 55 gallon tank of sodium hypochlorite solution to a drip feed connection to the inlet side of the existing chlorine contact basin, including piping, containment, and controls; installation of a new liquid dechlorination system consisting of two (2) 24 GPD chemical feed pumps in an induced suction arrangement from a 55 gallon tank of sodium bisulfite solution to a drip feed connection to the existing chlorine contact basin discharge trough, including piping, containment, and controls; in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. Note the existing tablet chlorination and dechlorination systems are to remain as back up. I certify that the construction of the above referenced project was observed to be built within substantial compliance, intent and in conformity with all applicable regulations and statutes and the project plans, specifications, and other supporting documentation comprising the Authorization to Construct Permit Application package. Signature WA&,am G L a,1194 Registration No. Date 11/03/2014 Mail this Certification to: Attn: Ron Berry Complex Permitting Unit DENR/DWR/Water Quality Programs 1617 Mail Service Center Raleigh, NC 27699-1617 14384 CAR0� �ESS/O ', 9 No. 14,384 ;� K4*L*A iNCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor Martin Lashua Vice President of Operations Carolina Water Services, Inc. of NC P. O. Box 240908 Charlotte, North Carolina 28224 Dear Mr. Lashua: John E. Skvarla, III Secretary May 9, 2014 SUBJECT: 'Authorization to Construct A to C No. 06046IA01 Carolina Water Services, Inc. of NC Abington Subdivision WWTP A letter of request for an Authorization to Construct was received April 29, 2014, by the Division of Water Resources (Division), and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of modifications to the existing 0.2 MGD Abington Subdivision WWTP, with discharge of treated wastewater into the Belews Creels in the Roanoke River Basin. This authorization results in no increase in design or permitted capacity and is awarded for the construction of the following specific modifications: Installation of a new liquid chlorination system consisting of two (2) 24 GPD chemical feed pumps in an induced suction arrangement from a 55 gallon tank of sodium hypochlorite solution to a drip feed connection to the inlet side of the existing chlorine contact basin, including piping, containment, and controls; installation of a new liquid dechlorination system consisting of two (2) 24 GPD chemical feed pumps in an induced suction arrangement from a 55 gallon tank of sodium bisulfite solution to a drip feed connection to the existing chlorine contact basin discharge trough, including piping, containment, and controls; in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. Note the existing tablet chlorination and dechlorination systems are to remain as back up. The Permittee is expected to maintain sufficient inventory, or access to inventory, beyond what is require to meet maximum treatment demand based on worst case delivery of liquid solutions, and operational monitoring to sustain continuous chlorination and dechlorination treatment. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Phone: 919-807-63001 Internet: www.ncwaterquality.org An Equal Opportunity\Affirmative Action Employer Martin Lashua, Vice President of Operations May 9, 2014 Page 2 of 3 This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No. NCO060461 issued May 1. 2012, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0060461. The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the Division. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by the Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Winston-Salem Regional Office, telephone number (336) 771 - 5000, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an on site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct and the approved plans and specifications. Mail the Certification to: NPDES Unit, DWR/DENR, 1617 Mail Service Center, Raleigh, NC 27699-1617. ' Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to .comply with the conditions of T15A:8G.0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III and IV facility at least daily, excluding weekends and holidays, must properly manage the facility, must document daily operation and maintenance of the facility, and must comply with all other conditions of T15A:8G.0202. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. During the construction of the proposed additions/modifications, the permittee shall continue to properly maintain and operate the existing wastewater treatment facilities at all times, and in such a manner, as necessary to comply with the effluent limits specified in the NPDES Permit. Z Martin Lashua, Vice President of Operations r May 9, 2014 Page 3 of 3 You are reminded that it is mandatory for the project to be constructed in accordance with the North Carolina Sedimentation Pollution Control Act, and when applicable, the North Carolina Dam Safety Act. In addition, the specifications must clearly state what the contractor's responsibilities shall be in complying with these Acts. Prior to entering into any contract(s) for construction, the recipient must have obtained all applicable permits from the State. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. If you have any questions or need additional information, please contact Ron Berry at telephone number (919) 807-6396. Sincerely, Thomas A. eeder, Director Division of Water Resources/NCDENR cc: William Langley, P.E. Henson Foley 16740 Birkdale Commons Pkwy Suite 200 Huntersville, NC 28078 DWR/Winston-Salem Regional Office, Water Quality Programs Central Files NPDES File Without Engineer's Certificate attached: Forsyth County Health Department CHLORINE CHAMBER/POST AERATION CHAMBER CHLORINE CHAMBER A separate chlorine chamber with a capacity of 4,167 gallons shall be supplied to provide a point of injecting chlorine into the effluent and allow proper mixing. The chamber volume is based on 30 . minutes retention of the average daily flow rate. ze& �j ��� dv� h The chlorine chamber shall be a detached part of the waste- water treatment plant. The chamber shall be conntructed of one - quarter inch structural steel plate and be rectangular in shape as shown on the plans. There shall be sufficient flow baffles installed to assure proper mixing of the chlorine solution with wastewater plant effluent. There shall be supplied within the chlorine chamber a _90•_ degree V-notch weir box mounted at the outlet end of the chamber. A stilling well with flowmeter mounting stand shall be included for installation of a f lowmeter . POST AERATION To provide for aeration of the effluent from the wastewater treatment plant prior to discharge, there shall be supplied as an, integral part of the chlorine contact chamber a 2,000 gallon posy_ aeration chamber. The chamber shall be completely separate from the chlorine contact chamber as shown on the plans. The chamber shall be constructed the same as the chlorine contact chamber. There shall be installed in the chamber a diffuser drop com- plete with diffusers so as to cause miniscule air diffusion bubbles through to , the surface., thereby providing maximum oxygenation efficiency. The diffuser drop will be equipped with a union to allow easy removal from the tank_ There shall also be provided between the union and the airheader a valve for regulat- ing the air supplied to the chamber or for complete shut off when required. The diffusers shall be the same as described in the specifications for the wastewater treatment plant. Abington WWTP NC#0060461 as Blowers Aeration Basin #1 100,000 Aeration Basin #2 100,000 Sludge Box screen EQ Basin 50, L/S j Digester 50,000 Office Digester Shed M Y� . . ..... . - GREY Line fence RED Line Flow BLUE Line Air IMPM rifler #1 19 rifier #2 mber