Loading...
HomeMy WebLinkAboutNC0062383_Permit Issuance_20050720�& WAT�c�Q O G r Mr. Jim Highley Senior Regional Manager Carolina Water Service, Inc. of NC P.O. Box 240908 Charlotte, North Carolina 28224 July 20, 2005 Michael F. Easley, Governor State of North Carolina William G. Ross, Jr., Secretary Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality Subject: NPDES PERMIT ISSUANCE Permit Number NCO062383 Queens Harbor WWTP Mecklenburg County Dear Mr. Highley: Division personnel have reviewed and approved your application for renewal of the subject permit. Accordingly, we are forwarding the attached final NPDES discharge permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated May 9, 1994 (or as subsequently amended). If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings (6714 Mail Service Center, Raleigh, North Carolina 27699- 6714). Unless such demand is made, this permit shall be final and binding. Please take notice that this permit is not transferable. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act, or any other Federal or Local governmental permits which may be required. If you have any questions or need additional information, please do not hesitate to contact Maureen Crawford of my staff at (919) 733-5083, extension 538. Sincerely, Z-2-/ 4F ' Alan W. Klimek, P.E. Director, Division of Water Quality cc: Central Files NPDES Unit Files Mooresville Regional Office 1617 MAIL SERVICE CENTER, RALEIGH, NORTH CAROLINA 27699-1617 - TELEPHONE 919-733-5083/FAX 919-733-0719 VISIT US ON THE WEB AT http://h2o.enr.state.nc.us/NPDES Permit NCO062383 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY . _ `u1- - TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provisions of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Carolina Water Service, Inc. of NC is hereby authorized to discharge wastewater from a facility located at the Queens Harbor Subdivision Off Yachtsman Harbor Drive Charlotte Mecklenburg County to receiving waters designated as the Catawba River (Lake Wylie) in the Catawba River Basin in accordance with effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This permit shall become effective September 1, 2005. This permit and authorization to discharge shall expire at midnight on June 30, 2010. Signed this day July 20, 2005. r• Alan W. Klimek, P.E., D;: ector Division of Water Quality By Authority of the Environmental Management Commission Permit NC0062383 SUPPLEMENT TO PERMIT COVER SHEET All previous NPDES Permits issued to this facility, whether for operation or discharge are hereby revoked, and as of this issuance, any previously issued permit bearing this number is no longer effective. Therefore, the exclusive authority to operate and discharge from this facility arises under the permit conditions, requirements, terms, and provisions included herein. Carolina Water Service, Inc. of N.C., is hereby authorized to: 1. Continue to operate an existing 0.150 MGD wastewater treatment system with the following components: ♦ Bar Screen ♦ Dual aeration basins with clarification modules ♦ Dual chlorine contact tanks with tablet chlorinators ♦ Effluent pump station ♦ Aerobic digestor The facility is located in Charlotte at Queens Harbor Subdivision on Pine Harbor Road in Mecklenburg County. 2. Discharge from said treatment works at the location specified on the attached map into the Catawba River (Lake Wylie), classified WS-V and B waters in the Catawba River Basin. �-.i.-..�� � �' �•}+ '� - f _ f J 'fir �.. ; (r�l I I u % I3ISCHARGE POINT 001=r } ,,1 ; f 1119 L• Y //IR . �\ Jam--- � k:�'� P '" � r. •�� 1�1�- P t � • x v/ ' Q 65 K ` is Wu Me~ V L� a Ad '` +✓� tea` ����11 J . (� ;•i w f 1 � `fit i � _b/���`, ry� 1'�" Bpi � . � � Ica �. �� p � • ��� >; %x`ir47. l 111i�, _:..". _ �.�1i�4i>. <^ % 4: \ i ��•-f%` ass \` �� Inl. 1 ���i��iY/(�\ �.-, i Queens Harbor WWTP County: Mecklenburg Stream Class: WS-V & B Receiving Stream: Catawba River (Lake Wylie) Sub -Basin: 030834 Latitude: 350 07' 15" Grid/ uad: G14SE Longitude: 810 02' 00" Permit NC0062383 A. (1.) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS During the period beginning on September 1, 2005 and lasting until expiration, the Permittee is authorized to discharge from outfall 001. Such discharges shall be limited and monitored by the Permittee as specified below: EF 'i UENT LIlVIITS " " M®NITO tTNO RE U11 RE1, NTS i � CHARACTERISTICS H' F E `z MonEhly WeeklyF ,`aiYy :Measurement Sample Sample ilenC BHT ... , _..... ��. Y Flow 0.150 MGD Continuous Recording Influent or Effluent BOD, 5-day (20°C) 30.0 mg/L 45.0 mg/L Weekly Composite Effluent Total Suspended Solids 30.0 mg/L 45.0 mg/L Weekly Composite Effluent NH3 as N Weekly Composite Effluent Fecal Coliform 200/100 nil 400/100 ml Weekly Grab Effluent (geometric mean) Total Residual Chlorine 28 µg/L 2/Week Grab Effluent Temperature CC) Weekly Grab Effluent Total Nitrogen Quarterly Composite Effluent (NOZ+NO3+ Total Phosphorus Quarterly Composite Effluent pH > 6.0 and < 9.0 standard units Weekly Grab Effluent Footnotes: 1. The limit for total residual chlorine will take effect March .1, 2007. Until then, the permittee shall monitor TRC [with no effluent limit]. THERE SHALL BE NO DISCHARGE OF FLOATING SOLIDS OR VISIBLE FOAM IN OTHER THAN TRACE AMOUNTS. A. (2.) NUTRIENT CONDITION This permit may be modified or revoked and reissued to include an effluent limitation on nutrients for this discharge depending upon the following: 1. The findings of a study by the Division determines nutrient control is necessary. 2. Local actions do not successfully reduce the nutrient loading on the receiving waters. 3. The onset of problem conditions in the receiving waters. CLASSIFIED/Vir Cbarfotte Vogt PUBLIC NOTICE Public Notice State of North Carolina Environmental Management Commissi'Zn/ NPDES Unit 1617 Mail Service Center that Raleigh, NC 27699-1617 rder Notification of Intent to Issue a NPDES Wastewater Permit �ted. the On the basis of thorough staff review and application of NC General statute ctor 143.21, Public law 92-500 and other lawful standards and regulations, the North Carolina 'Environmental Management Commission proposes to issue a National Pollutant Discharge Elimination System (NPDES) wastewater permit to the person(s) listed below effective 45 days.from the publish date of.this notice. Written Comments regarding the proposed permit will be accepted until 30 days after the publish date of this notice. All co nts received prior to that date are considered in the final detetminatio regarding the proposed permit. The Director of the NC Division of ter Quality may decide to L, hold a public meeting for the proposed p it should the Division receive 4 a significant degree of interest. Copies of thedraft permit and other pporting information on file used to determine conditions present in th draft permit are available upon request and payment of the cost of rep duetion. Mail comments and/or requests. for information to the N Divi n of Water Quality at the above address or that call the Point Source an at 919-733-5083, extension 520. Please der include the NPDES pe . number (attached). in any communication. ed. Interested persons may also visit the Division of Water Quality at 512 N. the Salisbury Street, Raleigh, NC 27604-1148 between the hours of 8:00 a.m. for and 5:00 p.m, to review the information on file. Carolina Water Service, -Inc. of NC, P.O. Box 240908, Charlotte North aro ma 28224 has applied or renewal o penru 0595 or its Emerald Point Subdivision. WWTP in Mecklenburg County. This permitted facility discharges treated wastewater to the Catawba River (Lake Wylie) in the Catawba River Basin. Currently, C$OD and ammonia nitrogen are water quality limited. This discharge may -affect future allocations in this portion of the watershed. . Carolina Water Service, Inc. of NC; P.O. Box 240908, Charlotte, North Carolina 28224 has applied for renewal of NPDES permit NCO062383 for its Queens Harbor Subdivision WWTP in Mecklenburg Cou "Chis permitted facility discharges treated wastewater to the Catawba Ri*(Lake Wylie) in the Catawba River Basin. Currently, CBOD and ammonia i'rty nitrogen. are water quality limited. This discharge may affect future 00 allocations in this portion of the watershed. :ng as Carolina Water Service, Inc, of NC, P.O. Box 240908, Charlotte, North se; Carolina 28224 has applied for renewal of NPDES permit NCO071242 for its Riverpointe Subdivision WWTP in Mecklenburg County. This permitted facility discharges treated wastewater to the Catawba River (Lake Wylie) in the Catawba River. Basin. Currently, CBOD and ammonia nitrogen are water quality limited. This discharge may affect future allocations t'n this portion of. the watershed. U-HAUL Co. of N.C. Place of Sale: Ashley Road Rental 1503 Ashley Road Charlotte, NC 28208 Date of Sale: 6116/05 Time of Sale: 11:00 AM y Customer Name: Jessica Regina Adams Last Known Address: 610 Concordia Ave, Charlotte, NC 28206 P Room Number: 2334 & WA%` MOOrp . � ��� Michael F. Easley, Governor State of North Carolina William G. Ross, Jr., Secretary MAY2 6 7 7- Department of Environment and Natural Resources 7 y Alan W. Klimek, P.E., Director Division of Water Quality May 25, 2005 MEMORANDUM To: Brett Setzer NC DENR / DEH / Regional Engineer Mooresville Regional Office From: Maureen Crawford \01 919-733-5083 x-538 NPDES Unit Subject: Review of Draft NPDES Permit NCO062383 Queens Harbor WWTP Mecklenburg County 3 2005 I 10111 - WATER QUALITY POINT SOu;.tCE BRANCH Please indicate below your agency's position or viewpoint on the draft permit and return this form by June 10, 2005. If you have any questions on the draft permit, please feel free to contact me at the telephone number shown above. RESPONSE: (Check one) Concur with the issuance of this permit provided the facility is operated and maintained properly, the stated effluent limits are met prior to discharge, and the discharge does not contravene the designated water quality standards. ❑ Concurs with issuance of the above permit, provided the following conditions are met: F-1 Opposes the issuance of the above permit, based on reasons stated below, or attached: 1617 MAIL SERVICE CENTER, RALEIGH, NORTH CAROLINA 27699-1617 - TELEPHONE 919-733-5083/FAX 919-733-0719 VISIT US ON THE WEB AT http://h2o.enr.state.nc.us/NPDES SOC PRIORITY PROJECT: Yes_ No X To: Permits and Engineering Unit Water Quality Section Attention: Carolyn Bryant Date: October 25, 2004 NPDES STAFF REPORT AND RECOMMENDATION County: Mecklenburg MRO# 04-92 Permit No. NCO062383 PART I - GENERAL INFORMATION 1. Facility and address: Queens Harbor WWTP c/o Carolina Water Service, Inc. P.O Box 240908 Charlotte, North Carolina 28224 2. Date of investigation: October 23, 2004 3. Report prepared by: Samar Bou-Ghazale, Env. Engineer.I OCT 2 9 2004 DENR - WATP CUALITY POINT SOURCE BRANCH 4. Persons contacted and telephone number: Mr. R. Adam James, ORC, (704) 525-7990. 5. Directions to site: From the intersection of Carowinds Blvd. and I-77 just south of Charlotte, travel west on Carowinds Blvd. 2.2 miles to York Road (Hwy 49). Turn left onto York Road and travel 3.0 miles to Shopton Road. Turn right on Shopton Road and travel 2.2 miles to Pine Harbor Road. From the intersection of Shopton Road and Pine Harbor Road, proceed west on Pine Harbor Road approximately 0.8 miles. Turn right into the Queens Harbor Condominium Complex. Proceed approximately 0.1 mile, the treatment plant is on the right, at the end of a very steep access road. 6. Discharge point(s). List for all discharge points: Latitude: 35 ° 07' 15" Longitude: 81 ° 02' 00" Attach a U.S.G.S. map extract and indicate treatment facility site and discharge point on map. USGS Quad No.: G 14 SE USGS Name: Lake Wylie, SC -NC 7. Site size and expansion area consistent with application? There is very limited size for expansion and upgrading. Page 1 8. Topography (relationship to flood plain included): The facility is located in a smallvalleywith a creek adjacent to the plant. The creek has a small drainage area. The facilities are not located in the 100-year flood plain. 9. Location of nearest dwelling: Approximately 500 feet from the WWTP site. 10. Receiving stream or affected surface waters: Lake Wylie (Catawba River). a. Classification: WS-IV and B b. River Basin and Subbasin No.: Catawba 03-08-34 C. Describe receiving stream features and pertinent downstream uses: The wastewater treatment plant discharges directly into Lake Wylie. Lake Wylie is used for recreational purposes. PART H - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of wastewater to be permitted: 0.150 MGD (Ultimate Design Capacity) b. What is the current permitted capacity of the wastewater treatment facility? 0.150 MGD C. Actual treatment capacity of the current facility (current design capacity)? 0.150 MGD d. Date(s) and construction activities allowed by previous Authorizations to Construct issued in the previous two years: N/A. e. Please provide a description of existing or substantially constructed wastewater treatment facilities: The existing wastewater treatment facilities consist of a bar screen, dual aeration basins with clarification modules, dual chlorine contact tanks with tablet chlorinators, effluent pump station and an aerobic digestor. £ Please provide a description of proposed wastewater treatment facilities: N/A. g. Possible toxic impacts to surface waters: Chlorine is added to the waste stream h. Pretreatment Program (POTWs only): N/A. 2. Residuals handling and utilization/disposal scheme: Sludge is removed as necessary by Liquid Waste, Inc. and transported to a CMUD WWTP for final disposal 3. Treatment plant classification (attach completed rating sheet): Class R (no change ofrating, no rating sheet attached). Page 2 4. SIC Code(s): 4952 Wastewater Code(s): 05 Main Treatment Unit Code: 05007 PART III - OTHER PERTINENT INFORMATION Is this facility being constructed with Construction Grant Funds or are any public monies involved (municipals only)? N/A. 2. Special monitoring or limitations (including toxicity) requests: TRC may need to be limited. 3. Important SOC, JOC or Compliance Schedule dates: N/A 4. Alternative Analysis Evaluation: There are no permit requirements at this time to evaluate alternatives to wastewater discharges since the facility is not in substantial non-compliance. 5. Air quality and/or groundwater concerns or hazardous materials utilized at this facility that may impact water quality, air quality or groundwater? No known air quality, groundwater or hazardous materials concerns. PART IV - EVALUATION AND RECOMMENDATIONS The Permittee, Carolina Water Service, Inc., is applying for renewal of the facility's NPDES permit to discharge treated domestic wastewater. A review of the past year's self -monitoring data, from 09/2003 through 08/2004, revealed only one Fecal violation. However, the average effluent TRC reported for the past year was 0.996 mg/l. Please note that a stream action level of 17 µg/l has been established for TRC to protect the receiving stream against chronic toxicity effects and 28 µg/l has been set as the maximum allowable effluent TRC concentration to protect against acute toxicity effects. Upon resolution of the TRC concern, it is recommended that the permit be renewed. Signature of Report reparer Water Quali Regional Supervisor �- Date Page 3 CAROLINA WATER SERVICE, INC. IIII AN AIIILIA�II III U�[11L TIIEC-SSoIIIII IC. Regional Office: 5701 Westpark Dr., Suite 101 P.O. Box 240908 Charlotte, NC 28224 Telephone: (704) 525-7990 FAX: (704) 525-8174 September 14, 2004 Mr. Charles H. Weaver NC DENR/Water Quality/NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Re: Notice of Renewal Intent Queens Harbor WWTP NPDES Permit No. NCO062383 Mecklenburg County Dear Mr. Weaver, Carolina Water Service, Inc. of NC hereby requests renewal of the aforementioned permit. No modifications have been made to this facility since the current permit was issued. Enclosed are one original and two copies of this letter, the application, and the facility's sludge management plan. If you should need additional information regarding the permit renewal application, or if you have questions about the information provided, please contact me at 704-525-7990. Sincerely, Tim Highley Sr. Regional Enclosures CC: Carl Daniel Martin Lashua CAROLINA WATER SERVICE, INC. j ANCAFFlU1A�T�E 01 Ulf► I�jjIIjjCSOII�I iCo Regional Office: 5701 Westpark Dr., Suite 101 P.O. Box 240908 Charlotte, NC 28224 Telephone: (704) 525-7990 FAX: (704) 525-8174 September 14, 2004 Mr. Charles H. Weaver NC DENR/Water Quality/NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Re: Queens Harbor WWTP NPDES Permit No. NCO062383 Sludge Management Plan Dear Mr. Weaver, Please be advised that sludge generated at the aforementioned facility is removed and disposed of by: Liquid Waste, Inc. 9300 Steele Creek Road Charlotte, NC 28273 704-588-2392 Jim Highley Senior Regional BioTech, Inc. PO Box 4569 W. Columbia, SC 29171 803-796-8925 FACT SHEET FOR EXPEDITED RENEWAL Permit Number Z Facility Name -e-erl) ( ✓ o✓ 'jl j f Reviewer 9W hI IC Basin/Sub-basin 0 Receiving Stream C i Stream Classification in permit S _ 1" Stream Classification in BIMS Is the stream impaired (listed on 303(d))? Is stream monitoring required? Do they need NH3 limit(s)? Do they need TRC limit(s)? Do they have whole -effluent toxicity testing? Are there special conditions? Any obvious compliance concerns? Existing Expiration Date Proposed Expiration Date Miscellaneous Comments: If expedited, is this' a simpler permit car a more difficult one?