HomeMy WebLinkAboutSWA000181_Response To Comments_20230224February 24, 2023
Project Name: HIBS
NCDEQ ID: SWA000181; HIBS Wolfspeed
County: Chatham
Jim Farkas, PE, Environmental Engineer
North Carolina Department of Environmental Quality [NCDEQ]
512 N. Salisbury St, Office 640E
Raleigh, NC 27604
Subject: SWA000181; HIBS Wolfspeed Stormwater Management Plan Fast Track Comment Response
Dear Mr. Farkas,
Please find enclosed the revised documentation requested for the HIBS Wolfspeed Project. The attached items
include:
Ix electronic copy of the letter giving Wes Feinman authority to sign on behalf of the Applicant, Whiting -
Turner (A hard copy of this item was provided, however an electronic copy does not appear to have been
uploaded to our file repository).
2x hard copies & Ix electronic copy of the revised pages of the Application (revised pages can be slip -
sheeted into the otherwise correct & complete Application that we already have).
2x hard copies & Ix electronic copy of any other items needed to address the above comments.
The comments provided in the email dated 2/21/2023 have been noted. Our responses are below in red:
➢ Part E5 of the Application —The project density does not appear to be calculated correctly. For projects without
existing BUA, project density is calculated as Proposed New BUA (3,613,628 sf) divided by the Total Project
Area (19,086,776 sf). 3,613,628 sf / 19,086,776 sf = 18.93% (18.84% is shown in the Application). Please revise
as needed.
■ The submitted application has been revised to reflect the correct impervious percentage.
➢ Part F7 of the Application — Please initial this item as being provided since documentation showing that Wes
Feinman can sign on behalf of the Applicant, Whiting -Turner, and documentation showing that the Applicant,
Whiting -Turner, is active and in good standing with the Secretary of State were provided.
■ The submitted application has been revised as requested.
➢ While not required for the approval of the ATC Permit, the following items were noted with the design. These
items may need to be addressed prior to Final Approval:
WSP USA
Suite 1500
434 Fayetteville Street
Raleigh, NC 27601
Tel.: +1 919 836-4040
Fax: +1 919 836-4099
WSP.Com
o Please ensure that the riprap apron for wet pond 95 is kept outside of the vegetated setback. Per 15A
NCAC 02H .1003(4)(b), "Vegetated setbacks may be cleared or graded, but shall be replanted and
maintained in grass or other vegetation". At the provided scale, it is unclear if the riprap apron is within
our outside of the vegetated setback. This item does not need to be corrected for ATC Approval, but must
be addressed prior to Final Approval.
■ The outlet protection for wet pond #S will be located outside of any stream buffers or vegetated
setbacks.
o This project is located within 5 miles of an airport (Siler City Municipal). While not required, it is
strongly recommended to use SCMs that do not promote standing water in accordance with G.S. 143-
214.7(c3)(https://www.nclea.gov/EnactedLegislation/Statutes/HTMLBySection/Chapter 143/GS 143-
214.7.html). Alternative SCMs that can be used within the 5 mile radius of a public airport are outlined in
Part E-4 of the Manual (https:Hdeq.nc.gov/media/9977/download).
■ Through internal project discussions, the potential of alternative Bws was discussed, but
ultimately, the decision to move forward with wet detention ponds was settled upon.
If you need additional information, please contact me at 919-836-4071 or by email at everett. ug�pton(4wsp.com.
Sincerely,
Everett C. Gupton, PE, PMP
Page 2