HomeMy WebLinkAboutSW1221002_Plansheet CL501A3.P2 - Other_20230223 J \ I
\ o
���
U LEGEND
PROPERTY LINE
BUILDING LINE Gresham Smith
o � I
m I W WATER LINE (SIZE VARIES) GS-NC P.C.
LU cn J An Affiliate of Gresham Smith
o — _ _ _ _ _ — SANITARY SEWER
o�Q vvI - - - - - - - STORM SEWER
Q
J N QN�V
N ; I UG-E UNDERGROUND ELECTRIC
h 0 I o� I \ 201 South College St.
v�' rn I \ G NATURAL GAS Suite 1950
I I vv N I v v Charlotte, NC 28244
/ °o Z �' I 3 \\ — — — — — — — UTILITY EASEMENT
LU
704.944.7970
Vo
\ z I \
FIRE DEPARTMENT
\ I \\ p Ad" CONNECTION (FDC)
I \ I z
46 ►�+ FIRE HYDRANT
REDUCER
"'°c I \\
o I ® ° \\ N WATER VALVE ,
LU
WATER TEE
° m \
\\ m \ II p p IV4 SANITARY ANGLE Gresham
\\ I
� I , I SO ® SANITARY STRUCTURES Smith
00
\\ II OS SANITARY MANHOLE
N \I I\ \ ® SANITARY CLEANOUT
lip 00
0 El \ \\ I STRUCTURE A4 A5 STRUCTURE LABEL /
o I \ \ I RIM:195.11
o•` j \ \ I
J°y\ ��\ IAOs h evi I I e
❑ i \ \, II a REG IONAL AIRPORT
� I Asheville Regional
0� I II �? NOTE:
z Airport
1. CONTRACTOR TO COORDINATE Terminal
o° c, , I z N UNDERGROUND UTILITIES TO BE A MINIMUM OF
"'
3 INCHES CLEAR BELOW THE BASE OF THE Modernization
\ IZ z GRADE BEAMS WHEN PASSING UNDERNEATH.\ 61 Terminal Drive Suite 1 2. NO UTILITY LINES SHALL PENETRATE THE
Foci i \ I zZ FOOTING AT THE CENTRAL ENERGY PLANT Fletcher, North Carolina 28732
EXCEPT FUEL LINES.
3. CONTRACTOR TO COORDINATE ALL
® J \ UNDERGROUND UTILITY ROUTINGS. UTILITIES 02/16/2022
SHALL BE KEPT A MINIMUM OF 12 INCHES
\ I @ CLEAR FROM ALL FOUNDATIONS IN PLAN. GS Project#: 43483.02
0 v \\°o�` I T � � // 4 SEE SITE ELECTRICAL PLANS O POWER,
COMMUNICATIONS, AND SITE LIGHTIN
in 00c � _
m � -co I i
Zd oj � ^ CD
chch � Z - °Jr�m "tNN f5lMMm UUX X �� J9n /ice /
0 =, EA
°UvOZZ �Q0 » � Lmom � aU Z o 053149CD / 11tip:/Q2/2zz
• = N ^� I Z ^ NNN I NE��•v\��
CO m NNN / / //'/�77� t IDI I I I IIHVOCN\\��
� N ?�w
QO > > >
i
C) Z Z Z& 0
O ® //
EICL
l9n 19n l�n 1 °l�n ®� ® NATHAN HUDGENS, PE
M O O o — UGE E1 J - -
O — — — _ — j i� NC 053149
� _ _ — - -__ - - - - - _ =---__—_—_ _ _
N - - - - - - - - - - - — ° 3 � � � 6Ge `tom
N — — - . - - - - - - — — — — — — —-— — ----- ^ - - \ wrmicyy)) REVISION
z C N N NO. DATE DESCRIPTION
O a Z 1 02/16/22 ISSUE FOR CONSTRUCTION
EXISTING SANITARY i � •0• \ p �O Z Z 2 05/02/22 AGENCY COMMENTS
MANHOLE RIM ELEVATION TO .—.—._
BE MAINTAINED AT 2144.59 TIE TO EXISTING MANHOLE —'
J� TIE TO EXISTING MANHOLE 3 08/19/22 AGENCY COMMENTS
IE (IN): 2140.60 IE (IN): 2129.90 \\ O 4 11/02/22 ASI 007
\
U — — ' • \
. _ \\\ \
2 PVC @ 1.00% D ' _ \.\ ` \
-0 UGE D D
_ _ _ _ \
v
U I °. v v °. ° v.'. V ? o rs ' I UGE v °
N d ° .D ? .v ❑ .D °. C O°. .DO o. DdOO O\
'.v ° D ° v °, D D ° D° v 5 L.F. -4" PVC @ 1.00% ` o D ..o - °o
CY)
o
.1� rt1
V. ° °
GF °o\ PROJECT
CO IE (OUT): 2141.00 °\o BOUNDARY
CL SEE PLUMBING PLANS FOR OR <` ` \°\
CONTINUATION OF SANITARY LINE o I o
D I o O \
°
a • \
Q I I ------------ _ °\
'�.
o D v • I i `; \ \
O
CD
CD
FIRE DEPARTMENT CONNECTION. -/ I 20' 0 20' 40'
CD
p SEE FIRE PROTECTION PLANS FOR DETAIL. ; o I
o
• I U ; O GRAPHIC SCALE
co UTILITY PLAN
00 KEYPLAN
I
�I Al ' A2 ' A3
�� CL501A3 . P2
�0 — — — — —i - - - - - i- - - - -
Q
UTILITY PLAN B1 � B2 � B3
A3
SCALE:
=20'1"
O
CONSTRUCTION DOCUMENTS
I