February 17, 2023
Subject:
Compliance Evaluation Inspection
Permit # WQ00033097
Facility: Eatons Crossing Irrigation System
Warren County
On February 13, 2023, Jim Westcott from the Raleigh Regional Office visited your
wastewater treatment and spray irrigation system and met with Dennis Wilson to evaluate
compliance with the subject permit.
The facility is permitted for the operation .02469 (MGD) wastewater treatment and
irrigation facility consisting of a dual -train wastewater treatment plant with an
electromagnetic influent flowmeter, a 3 mm fine screen with automatic auger and
screening press, a .009466 gallon flow equalization tank with a course -bubble diffuser
served by two 360 CFM blowers and two 35 GPM pumps, two .009605 gallon anoxic tanks
each served by two 2.1 Hp submersible mixers and a 2.5 GPH carbon -source metering
system, two .006744 gallon aeration tanks each with fine -bubble diffusers served by dual
245 CFM blowers and a 2.5 GPM alum metering system for phosphorous removal, two flat
plate membrane bioreactors (MBR) each with a 15 ft2 membrane area with an air -scour
system served by the aforementioned dual 245 CFM blowers and two 210 GPM anoxic
recycle pumps, a 325 gallon storage tank for membrane cleaning, a .0011 gallon chemical
cleaning/storage tank, a .015 gallon aerobic digester with a course -bubble diffuser served
by the aforementioned dual 245 CFM blowers, an ultraviolet disinfection unit with two
banks containing four UV lamps each, a concrete lift station with dual 70 GPM pumps, an
electromagnetic effluent flowmeter, a 125 kW auxiliary generator for backup power supply
to essential treatment units, a 0.9 MG synthetically -lined wet weather storage pond, dual
124 GPM irrigation dosing pumps, a 10.7 acre spray irrigation area containing 10 zones
and all associated piping, valves, controls, and appurtenances with no discharge of wastes
to surface waters.
GCE
North Carolina Department of I nv ronmcnlal Qualuy I Dlvlsion of Water Resources
Raleigh Regional (dice 1 18011 Barrett Drive I Raleigh. North Carolina 27609
919 791..1200
DocuSign Envelope ID: 64COOCE1-63C2-476D-AD31-0C9E4F987477
The permit, which was issued June 4, 2019, is current through May 31, 2025. Section I (1)
of the subject permit requires the permittee to request renewal of the permit no later than
six months prior to the expiration of the permit on official division forms. Division records
indicate the required annual fee for the period ending August 31, 2022, due May 2, 2022,
has been paid.
Findings during the inspection were as follows:
At the time of inspection, required logbook, maintenance and ORC records, irrigation
calibration records, spill prevention plan, residuals management plan, annual standard soil
fertility analysis, NDMR and NDAR-1 records were submitted as required and available for
review. All records were organized and available for a period of five years. The overall
condition and integrity of the wastewater system and facility grounds were properly
managed. At the time of inspection, the ORC was on -site and gave a comprehensive tour of
the treatment system and its components.
The membranes are back pulsed as required based upon a pressure increase and the
decrease in flux from the system. The reject waters are returned to the influent basin.
The facility grounds and lagoon perimeter were securely fenced with proper signage and
the liner was clean and in good condition. The freeboard level was clearly delineated with
67" of available volume.
Meritech laboratory draws effluent samples for analysis. No discrepancies in the data were
noted and the facility is drawing the required samples at the frequency required by the
permit. Influent and Effluent flows are recorded from in line magnetic meters.
Maintenance activities are recorded weekly and monthly for all service equipment and
facility grounds. A moisture sensor and visual/audible alarm is located at the pump house
with the control panel. Effluent discharge to the spray field is controlled by A VFD and
flow/duration are data logged and recorded each spray event per zone selected. The spray
field was well maintained, secured with proper signage and good condition with no signs of
ponding.
Residuals from the facility are documented and removed from the facility as required by
Granville septic and transferred to the Warren County WWTF for disposal.
Annual standard fertility tests are conducted through NCDA&CS Department of Agriculture.
All metering equipment and calibrations are conducted through Chadwick
Instrumentation.
The system has an integrated auto dialer for mechanical and/or emergency callout
response. The on -site backup generator auto cycles each Monday and is maintained with a
service contract annually.
ARE
North Carolina Department of Environmental Quality 1 Division of Water Resources
512 North Salisbury Street 1 1611 Mail Service Center 1 Raleigh. North Carolina 27699-161 1
919.707 9000
DocuSign Envelope ID: 64COOCE1-63C2-476D-AD31-0C9E4F987477
Please continue to periodically inspect and evaluate the wastewater spray irrigation
system components are properly maintained and operating as designed. Maintain all
associated operational records onsite for a period of five years as required by the subject
permit.
If you have questions or comments about this inspection or the requirements to take
corrective action (if applicable), then please contact Jim Westcott at 919-791-4247 or
james.westcott@ncdenr.gov.
Sincerely, DocuSigned by:
FialnA,SSOt f. han,lAd,
B2916E6AB32144F...
Vanessa E. Manuel, Assistant Regional Supervisor
Water Quality Regional Operations Section