Loading...
HomeMy WebLinkAboutSW6220802_Supplement-EZ Form_20230217SUPPLEMENT-EZ COVER PAGE L6ADSUPPLEMENTFORMS PROJECT INFORMATION 1 Project Name Champs Convenience Store 2 Pro act Area ac) 3,46 3 Coastal Wetland Area ac) 0 4 Surface Water Area ac — 0 5 _ Is thisHI h or Low Density? Both High and Low Density —_ :] 6 _project Does this project use an off -site kM? No Yes 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003 4)(c-d ? MIA 10 j Is streambank stabilization proposed on this project? No NUMBER AND TYPE QF SCMs: 11 Infiltration System 1 12 Sioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement — 16 Sand Filter 17 Rainwater Harvesting (RWH) _ — — 18 Green Roof - 19 Level S reader -Filter Stri (LS-FS 20 Disconnected impervious Surface DI5 — 21 Treatment Swale — 22 _Dry Pond �- 23 StormFilter 24 Silva Cell — 25 Bayfilter 26 Filterra LOAD SUPPLEMENT FORMS Certification Statement: I certify, under penalty of law that th.is Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here: 0OS H Ca RESS p��.,, sea i Sig re of D igner Date DRAINAGE AREAS 1 Is this a hi h densit ro'ect? Yes 2 If so, number of drains a areasISCMs 1 3 Does this project have low density areas? Yes 4 If so, number of low densy drainage areas 1 5 Is all/part of this project subject to previous rule versions? No FORMS LOAUD DialNAGE AREA INFORMATION Entire Situ 1 LD 1 4 Type of SCIVI Infiltration 5 Total drainage areas ft 150,717.60 sf 87,120.00 sf 68,389.20 sf 6 Onsite drainage area (sq ft 150,717.60 sf 82,328.40 sf 68,389.20 sf 7 Offsite drainage area (sq ft 0 sf 4,791.60 sf 0 sf 8 Total BUA in project s ft 78408 sf 72310 sf 10,890.00 sf 9 New BUA on subdivided lots (subject to permitting) 1 (sq ft NA NA NA 10permitting) New BUA not on subdivided lots (subject to s 78408 sf 67518 sf 10.890,00 sf 11 Offsite BUA (sq ft 0 sf 4792sf 0 sf 12 Breakdown of new BUA not on subdivided lots: Parking (sq ft 8086 sf 8086 sf 0 sf Sidewalks ft 10271 sf 4608 sf 5,662.80 sf Roof (sq ft 6600 sf 6600 sf _0 sf Roadwa sg ft 52819 sf 42,800 sf 5,227,20 sf Future (sq ft NA NA NA Other, please specify in the comment box below s 8 5424 sf 5424 sf 0 sf 13 New infiltrating permeable pavement on subdivided lots s ft NA NA NA 14 New infiltrating permeable pavement not on Isubdivided lots (sq ft NA NA NA 15permitting) Existing BUA that will remain (not subject to s ft NA NA 0 sf 16 Existing BUA that is already permitted s ft NA NA 0 sf 17 Existing BUA that will be removed (sq ft NA NA 0 sf 18 Percent BUA 52% 83% 16% 19 Desi n storm inches 1.0 in 20 Design volume of SCM cu ft 7260 of 21 1 Calculation method for design volume MDC5 ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): "Other' impervious came from big fuel island ( 3;360sf), small fuel island ( 1,056.00 sf), big slab over fuel tanks ( 528 sf), small slab over fuel tanks ( 96 sf), dumpster pad and apron ( 384 sf). INFILTRATION SYSTEM 1-1 Drainace area number 1 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes 4 Is the SCM located awa from contaminated soils? Yes 5 What are the side slopes of the SCM (H:V or enter "Vertical' for trenches)? vertical 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No 7 Are the inlets, outlets, and receiving stream protected from erosion 10 ear storm ? Yes 8 Is there an overflow or bypass far inflow volume in excess of the design volume? Yes is the method for dewaterin the SCM for maintenance? Pump (preferred) If ap licable, will the SCM be cleaned out after construction? Yes Does the maintenance access com I with General MDC 8)? Yes rWhat Does the drains a easement comp) with General MDC (9)? Yes If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? N/A Is there an O&M Agreement that complies with General MDC (11)? Yes 15 Is there an 0&M Plan that complies with General MDC (12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 INFILTRATION Was the SCM designed by an NC licensedprofessional? Yes SYSTEM MDC FROM 02H .1051 18 Proposed slope of the subgrade surface (%) 0% 19 Are terraces or baffles provided? No 20 Type of pretreatment: Other 1_21l n..f.. 21 Was the soil investigated in the footprint and at the elevation of the infiltrations stem? Yes 22 SHWT elevation fmsi) 326.00 23 Depth to SHWT per soils report (in) 24.00 24 Ground elevation at boring in soils report (fmsi) 328.00 25 Is a detailed hydrogeologic study attached if the separation is between 1 and 2 feet? NIA 26 Soil infiltration rate (inlhr) 0.60 27 Factor of safety (FS) (2 is recommended): 2.27 elevations 29 1 Bottom elevation (fmsl) 328 ft 30 IStoraqe elevation ffmsl) 330.37 ft For Basins Only 32 Bottom surface area ft2 �47 33 storage elevation surface area ft2 ft c.,� r.......H..t nil,. 34 Length (ft) 93 ft 35 Width (ft) 56 ft 36 Perforated pipe diameter, if applicable (inches) NA 37 Number of laterals NA 38 Total length of perforated piping NA 39 Stone type, if applicable #4 40 Stone porosity (%) 40% 41 Is stone free of fines? Yes 42 Is the stone wrapped in eotextile fabric? Yes 43 Has at least one ins ection port been provided? Yes 44 Design volume of SCM (cu ft) 45 1 Time to draw down hours) .— DDITIONAL INFORMATION — 46 Please use this space to provide any additional information about tt infiltration system(s): filtration system is a network of underground storm chambers with 2 foot sumps in let structures to serve as forebays. Infiltration 1 2:50 PM 2/10/2023