February 22, 2023
SUBJECT: Compliance Inspection Report
Holly Ridge WWTF
Non -discharge Permit No. WQ0019907
Onslow County
Dear Permittee:
The North Carolina Division of Water Resources conducted an inspection of the Holly Ridge WWTF on
2/15/2023. This inspection was conducted to verify that the facility is operating in compliance with the
conditions and limitations specified in Non -discharge Permit No. WQ0019907. The findings and
comments noted during this inspection are provided in the enclosed copy of the inspection report
entitled "Compliance Inspection Report". There were no significant issues or findings noted during the
inspection and therefore, a response to this inspection report is not required.
If you should have any questions, please do not hesitate to contact Helen Perez with the Water
Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at
helen.perez@ncdenr.gov.
Sincerely,
�DocuSigned by:
ION- 11AarflOA.
-7F141E73B6F3456...
Morella Sanchez -King, Regional Supervisor
Water Quality Regional Operations Section
Wilmington Regional Office
Division of Water Resources, NCDEQ
ATTACHMENTS
Cc: WQS Wilmington Regional Office - File
Upload to Laserfiche
Kary Herndon — electronic copy
ODE
North Carolina Department of Environmental Quality I Division of Water Resources
Wilmington Regional Office 1127 Cardinal Drive Extension I Wilmington. North Carolina 28405
910.796.7215
DocuSign Envelope ID: 859390DA-F686-4239-98A9-B11F00102270
Compliance Inspection Report
Permit: WQ0019907 Effective: 11/23/22
SOC: Effective:
County: Onslow
Region: Wilmington
Expiration: 11/30/29
Expiration:
Owner : Onslow Water and Sewer Authority
Facility: Holly Ridge WWTF
286 N Jenkins St Ext
Holly Ridge NC 28445
Contact Person: David M Mohr Title: Chief Operations Officer Phone: 910-937-7521
Directions to Facility:
System Classifications: SI, WW2,
Primary ORC: Kary Alexander Herndon Certification: 1010314 Phone: 910-937-7575
Secondary ORC(s):
On -Site Representative(s):
On -site representative Kary Alexander Herndon 910-937-7575
Related Permits:
WQ0034067
WQCS00249
WQ0029945
NC0025895
Onslow Water and Sewer Authority - Stump Sound Wastewater Infrastructure
Improvements Sewer
Onslow Water and Sewer Authority - ONWASA Collection System
Onslow Water and Sewer Authority - Summerhouse WWTF
Town Of Holly Ridge - Holly Ridge WWTP
Inspection Date: 02/15/2023
Primary Inspector: Helen I Perez
Secondary Inspector(s):
Entry Time 09:30AM
1-DocuSigned by:
46,Q,en, \ene�
1D645B4A39694BE...
Geoff Kegley—DocuSigned by:
Reason for Inspection: Routine
"-0017E2515D3B417...
Permit Inspection Type: Wastewater Irrigation
Facility Status: Compliant
Question Areas:
Not Compliant
▪ Treatment Flow Measurement -Effluent
▪ Treatment Flow Measurement -Water
Use Records
▪ Record Keeping
▪ Treatment Disinfection
(See attachment summary)
Exit Time: 11:30AM
Phone: 910-796-7387
Phone :
Inspection Type: Compliance Evaluation
▪ Treatment Flow Measurement -Influent
▪ Treatment
▪ Treatment Lagoons
▪ Treatment Flow Measurement
▪ Miscellaneous Questions
▪ Treatment Barscreen
▪ End Use -Irrigation
▪ Standby Power
Page 1 of 6
DocuSign Envelope ID: 859390DA-F686-4239-98A9-B11F00102270
Permit: WQ0019907 Owner - Facility:Onslow Water and Sewer Authority
Inspection Date: 02/15/2023 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Inspection Summary:
A routine compliance inspection of the Holly Ridge WWTF was conducted on February 15, 2023. The purpose of the
evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit
WQ0019907. Kary Herndon, ORC, was present during the inspection.
This facility is a facultative lagoon treatment and irrigation system with a flow limit of 224,673 gpd. ONWASA has the ability
to divert flow from the Jenkins Street Pump Station in Holly Ridge to the Summerhouse WWTF for treatment when needed.
Effluent is stored in a 51-day storage pond before irrigating on 10 spray fields.
A review of monitoring reports since the last inspection shows no groundwater issues on the GW-59s and 3 flow
exceedances in June 2020, February 2021 and June 2021 on the NDMRs,
ONWASA was issued a Pump and Haul Permit on February 8,2023 to pump and haul wastewater from the Summerhouse
WWTF's 5-day upset pond to the Holly Ridge facility due to upcoming operational improvements at Summerhouse. An
estimated 2 MG will be pumped and hauled during an extended time to make sure the flow at Holly Ridge is not exceeded.
Currently, there are 2 modification applications under review for the Holly Ridge WWTF. A major modification includes
building a new wastewater treatment facility and high -rate infiltration basins at the current irrigation field site. A minor
modification includes constructing a forcemain from Holly Ridge WWTF to Summerhouse WWTF.
The facility is compliant with Non -Discharge Permit WQ0019907. Please review the comment sections of the inspection
report for more details.
Page 2 of 6
DocuSign Envelope ID: 859390DA-F686-4239-98A9-B11F00102270
Permit: WQ0019907 Owner - Facility:Onslow Water and Sewer Authority
Inspection Date: 02/15/2023 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Type
Reuse (Quality)
Infiltration System
Single Family Spray, LR
Activated Sludge Spray, LR
Activated Sludge Spray, HR
Activated Sludge Drip, LR
Recycle/Reuse
Single Family Drip
Lagoon Spray, LR
Treatment
Are Treatment facilities consistent with those outlined in the current permit?
Do all treatment units appear to be operational? (if no, note below.)
Yes No NA NE
•
Yes No NA NE
Comment: Lagoon Cell #4 has only 1 Blue Frog floating aerator, not 3, as stated in the description of the
current permit. A Blue Frog floating aerator was out of Cell #3 for repair. The 22,400 gallon
aerobic sludge digester is not in operation and Field 1/1 D has not been constructed.
Treatment Flow Measurement -Influent
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑•
❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The influent flowmeter is used for reporting and was calibrated by Glover Instruments and
Controls on 12/05/2022.
Treatment Flow Measurement -Water Use Records
Is water use metered?
Are the daily average values properly calculated?
Comment:
Treatment Flow Measurement -Effluent
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Yes No NA NE
• ❑ • ❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Page 3 of 6
DocuSign Envelope ID: 859390DA-F686-4239-98A9-B11F00102270
Permit: WO0019907 Owner - Facility:Onslow Water and Sewer Authority
Inspection Date: 02/15/2023 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Comment: The effluent/irrigation flowmeter was calibrated by Glover Instruments and Controls on
12/05/2022.
Standby Power
Is automatically activated standby power available?
Is generator tested weekly by interrupting primary power source?
Is generator operable?
Does generator have adequate fuel?
Yes No NA NE
• ▪ ❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑ •
❑ ❑ ❑ •
Comment: There are 2 generators on -site, one provides standby power to the office with the influent
flowmeter and the other to the Blue Frog aerators. They are tested weekly.
Treatment Barscreen
Is it free of excessive debris?
Is disposal of screenings in compliance?
Are the bars spaced properly?
Is the unit in good condition?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑ •
• ❑ ❑ ❑
Comment: Influent flows through a manual barscreen and grit chamber. The barscreen is cleaned daily
and screenings are hauled off -site approximately every 2 weeks.
Treatment Disinfection
Is the system working?
Do the fecal coliform results indicate proper disinfection?
Is there adequate detention time (>=30 minutes)?
Is the system properly maintained?
If gas, does the cylinder storage appear safe?
Is the fan in the chlorine feed room and storage area operable?
Is the chlorinator accessible?
If tablets, are tablets present?
Are the tablets the proper size and type?
Is contact chamber free of sludge, solids, and growth?
If UV, are extra UV bulbs available?
If UV, is the UV intensity adequate?
# Is it a dual feed system?
Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)?
If yes, then is there a Risk Management Plan on site?
If yes, then what is the EPA twelve digit ID Number? (1000-
If yes, then when was the RMP last updated?
Comment: No comment.
Record Keeping
Yes No NA NE
▪ ❑ ❑ ❑
❑ ❑ ❑ •
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ • ❑
❑ ❑ • ❑
• ▪ ❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑ •
• ❑ ❑ ❑
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
Yes No NA NE
Page 4 of 6
DocuSign Envelope ID: 859390DA-F686-4239-98A9-B11F00102270
Permit: WQ0019907 Owner - Facility:Onslow Water and Sewer Authority
Inspection Date: 02/15/2023 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Is a copy of current permit available?
Are monitoring reports present: NDMR?
NDAR?
Are flow rates less than of permitted flow?
Are flow rates less than of permitted flow?
Are application rates adhered to?
Is GW monitoring being conducted, if required (GW-59s submitted)?
Are all samples analyzed for all required parameters?
Are there any 2L GW quality violations?
Is GW-59A certification form completed for facility?
Is effluent sampled for same parameters as GW?
Do effluent concentrations exceed GW standards?
Are annual soil reports available?
# Are PAN records required?
# Did last soil report indicate a need for lime?
If so, has it been applied?
Are operational logs present?
Are lab sheets available for review?
Do lab sheets support data reported on NDMR?
Do lab sheets support data reported on GW-59s?
Are Operational and Maintenance records present?
Were Operational and Maintenance records complete?
Has permittee been free of public complaints in last 12 months?
Is a copy of the SOC readily available?
No treatment units bypassed since last inspection?
• ❑ ❑ ❑
❑ ❑ ❑ •
❑ ❑ ❑ •
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑ •
❑ ❑ ❑ •
• ❑ ❑ ❑
❑ ❑ ❑ •
❑ ❑ ❑ •
❑ ❑ ❑ •
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: Operation and maintenance logs were available for review and appeared to be complete.
Records for the maintenance of the Blue Frog aerators are documented electronically through
tablets. The ONWASA central lab analyzes most reported parameters for the NDMR, and field
parameters are analyzed at ONWASA's Summerhouse WWTF.
End Use -Irrigation
Are buffers adequate?
Is the cover crop type specified in permit?
Is the crop cover acceptable?
Is the site condition adequate?
Is the site free of runoff / ponding?
Is the acreage specified in the permit being utilized?
Is the application equipment present?
Yes No NA NE
• ❑ ❑ ❑
❑•❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Page 5 of 6
DocuSign Envelope ID: 859390DA-F686-4239-98A9-B11F00102270
Permit: WQ0019907 Owner - Facility:Onslow Water and Sewer Authority
Inspection Date: 02/15/2023 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Is the application equipment operational?
Is the disposal field free of limiting slopes?
Is access restricted and/or signs posted during active site use?
Are any supply wells within the CB?
Are any supply wells within 250' of the CB?
How close is the closest water supply well?
Is municipal water available in the area?
# Info only: Does the permit call for monitoring wells?
Are GW monitoring wells located properly w/ respect to RB and CB?
Are GW monitoring wells properly constructed, including screened interval?
Are monitoring wells damaged?
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑ •
❑ ❑ ❑ •
❑ ❑ ❑ •
• ❑ ❑ ❑
❑ ❑ ❑ •
❑ ❑ ❑ •
Comment: The high-level alarms at the effluent pump station, located at the plant site, were operational
and the Missions telemetry system contacts the operator on -call. Effluent flows through a force
main approximately 4 miles to the storage pond at the irrigation site. The ONWASA collection
system staff checks this priorty line regularly as required. The fields were in adequate
condition. Field 1/1D was never constructed. The 13.3 MG storage pond is lined and the berm
was in good condition. Freeboard was between 3-4 feet. The irrigation pump station is
monitored by the Missions system.