HomeMy WebLinkAboutWQ0019907_Compliance Evaluation Inspection_20230215DocuSign Envelope ID: 859390DA-F686-4239-98A9-B11F00102270 ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director David M Mohr Onslow Water and Sewer Authority 228 Georgetown Rd Jacksonville, NC 28540 NORTH CAROLINA Environmental Quality February 22, 2023 SUBJECT: Compliance Inspection Report Holly Ridge WWTF Non -discharge Permit No. WQ0019907 Onslow County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Holly Ridge WWTF on 2/15/2023. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0019907. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Helen Perez with the Water Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at helen.perez@ncdenr.gov. Sincerely, �DocuSigned by: ION- 11AarflOA. -7F141E73B6F3456... Morella Sanchez -King, Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Wilmington Regional Office - File Upload to Laserfiche Kary Herndon — electronic copy ODE North Carolina Department of Environmental Quality I Division of Water Resources Wilmington Regional Office 1127 Cardinal Drive Extension I Wilmington. North Carolina 28405 910.796.7215 DocuSign Envelope ID: 859390DA-F686-4239-98A9-B11F00102270 Compliance Inspection Report Permit: WQ0019907 Effective: 11/23/22 SOC: Effective: County: Onslow Region: Wilmington Expiration: 11/30/29 Expiration: Owner : Onslow Water and Sewer Authority Facility: Holly Ridge WWTF 286 N Jenkins St Ext Holly Ridge NC 28445 Contact Person: David M Mohr Title: Chief Operations Officer Phone: 910-937-7521 Directions to Facility: System Classifications: SI, WW2, Primary ORC: Kary Alexander Herndon Certification: 1010314 Phone: 910-937-7575 Secondary ORC(s): On -Site Representative(s): On -site representative Kary Alexander Herndon 910-937-7575 Related Permits: WQ0034067 WQCS00249 WQ0029945 NC0025895 Onslow Water and Sewer Authority - Stump Sound Wastewater Infrastructure Improvements Sewer Onslow Water and Sewer Authority - ONWASA Collection System Onslow Water and Sewer Authority - Summerhouse WWTF Town Of Holly Ridge - Holly Ridge WWTP Inspection Date: 02/15/2023 Primary Inspector: Helen I Perez Secondary Inspector(s): Entry Time 09:30AM 1-DocuSigned by: 46,Q,en, \ene� 1D645B4A39694BE... Geoff Kegley—DocuSigned by: Reason for Inspection: Routine "-0017E2515D3B417... Permit Inspection Type: Wastewater Irrigation Facility Status: Compliant Question Areas: Not Compliant ▪ Treatment Flow Measurement -Effluent ▪ Treatment Flow Measurement -Water Use Records ▪ Record Keeping ▪ Treatment Disinfection (See attachment summary) Exit Time: 11:30AM Phone: 910-796-7387 Phone : Inspection Type: Compliance Evaluation ▪ Treatment Flow Measurement -Influent ▪ Treatment ▪ Treatment Lagoons ▪ Treatment Flow Measurement ▪ Miscellaneous Questions ▪ Treatment Barscreen ▪ End Use -Irrigation ▪ Standby Power Page 1 of 6 DocuSign Envelope ID: 859390DA-F686-4239-98A9-B11F00102270 Permit: WQ0019907 Owner - Facility:Onslow Water and Sewer Authority Inspection Date: 02/15/2023 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: A routine compliance inspection of the Holly Ridge WWTF was conducted on February 15, 2023. The purpose of the evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit WQ0019907. Kary Herndon, ORC, was present during the inspection. This facility is a facultative lagoon treatment and irrigation system with a flow limit of 224,673 gpd. ONWASA has the ability to divert flow from the Jenkins Street Pump Station in Holly Ridge to the Summerhouse WWTF for treatment when needed. Effluent is stored in a 51-day storage pond before irrigating on 10 spray fields. A review of monitoring reports since the last inspection shows no groundwater issues on the GW-59s and 3 flow exceedances in June 2020, February 2021 and June 2021 on the NDMRs, ONWASA was issued a Pump and Haul Permit on February 8,2023 to pump and haul wastewater from the Summerhouse WWTF's 5-day upset pond to the Holly Ridge facility due to upcoming operational improvements at Summerhouse. An estimated 2 MG will be pumped and hauled during an extended time to make sure the flow at Holly Ridge is not exceeded. Currently, there are 2 modification applications under review for the Holly Ridge WWTF. A major modification includes building a new wastewater treatment facility and high -rate infiltration basins at the current irrigation field site. A minor modification includes constructing a forcemain from Holly Ridge WWTF to Summerhouse WWTF. The facility is compliant with Non -Discharge Permit WQ0019907. Please review the comment sections of the inspection report for more details. Page 2 of 6 DocuSign Envelope ID: 859390DA-F686-4239-98A9-B11F00102270 Permit: WQ0019907 Owner - Facility:Onslow Water and Sewer Authority Inspection Date: 02/15/2023 Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Reuse (Quality) Infiltration System Single Family Spray, LR Activated Sludge Spray, LR Activated Sludge Spray, HR Activated Sludge Drip, LR Recycle/Reuse Single Family Drip Lagoon Spray, LR Treatment Are Treatment facilities consistent with those outlined in the current permit? Do all treatment units appear to be operational? (if no, note below.) Yes No NA NE • Yes No NA NE Comment: Lagoon Cell #4 has only 1 Blue Frog floating aerator, not 3, as stated in the description of the current permit. A Blue Frog floating aerator was out of Cell #3 for repair. The 22,400 gallon aerobic sludge digester is not in operation and Field 1/1 D has not been constructed. Treatment Flow Measurement -Influent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑• ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: The influent flowmeter is used for reporting and was calibrated by Glover Instruments and Controls on 12/05/2022. Treatment Flow Measurement -Water Use Records Is water use metered? Are the daily average values properly calculated? Comment: Treatment Flow Measurement -Effluent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Yes No NA NE • ❑ • ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 3 of 6 DocuSign Envelope ID: 859390DA-F686-4239-98A9-B11F00102270 Permit: WO0019907 Owner - Facility:Onslow Water and Sewer Authority Inspection Date: 02/15/2023 Inspection Type : Compliance Evaluation Reason for Visit: Routine Comment: The effluent/irrigation flowmeter was calibrated by Glover Instruments and Controls on 12/05/2022. Standby Power Is automatically activated standby power available? Is generator tested weekly by interrupting primary power source? Is generator operable? Does generator have adequate fuel? Yes No NA NE • ▪ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • Comment: There are 2 generators on -site, one provides standby power to the office with the influent flowmeter and the other to the Blue Frog aerators. They are tested weekly. Treatment Barscreen Is it free of excessive debris? Is disposal of screenings in compliance? Are the bars spaced properly? Is the unit in good condition? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • • ❑ ❑ ❑ Comment: Influent flows through a manual barscreen and grit chamber. The barscreen is cleaned daily and screenings are hauled off -site approximately every 2 weeks. Treatment Disinfection Is the system working? Do the fecal coliform results indicate proper disinfection? Is there adequate detention time (>=30 minutes)? Is the system properly maintained? If gas, does the cylinder storage appear safe? Is the fan in the chlorine feed room and storage area operable? Is the chlorinator accessible? If tablets, are tablets present? Are the tablets the proper size and type? Is contact chamber free of sludge, solids, and growth? If UV, are extra UV bulbs available? If UV, is the UV intensity adequate? # Is it a dual feed system? Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000- If yes, then when was the RMP last updated? Comment: No comment. Record Keeping Yes No NA NE ▪ ❑ ❑ ❑ ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ • ▪ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ • • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ Yes No NA NE Page 4 of 6 DocuSign Envelope ID: 859390DA-F686-4239-98A9-B11F00102270 Permit: WQ0019907 Owner - Facility:Onslow Water and Sewer Authority Inspection Date: 02/15/2023 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is a copy of current permit available? Are monitoring reports present: NDMR? NDAR? Are flow rates less than of permitted flow? Are flow rates less than of permitted flow? Are application rates adhered to? Is GW monitoring being conducted, if required (GW-59s submitted)? Are all samples analyzed for all required parameters? Are there any 2L GW quality violations? Is GW-59A certification form completed for facility? Is effluent sampled for same parameters as GW? Do effluent concentrations exceed GW standards? Are annual soil reports available? # Are PAN records required? # Did last soil report indicate a need for lime? If so, has it been applied? Are operational logs present? Are lab sheets available for review? Do lab sheets support data reported on NDMR? Do lab sheets support data reported on GW-59s? Are Operational and Maintenance records present? Were Operational and Maintenance records complete? Has permittee been free of public complaints in last 12 months? Is a copy of the SOC readily available? No treatment units bypassed since last inspection? • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: Operation and maintenance logs were available for review and appeared to be complete. Records for the maintenance of the Blue Frog aerators are documented electronically through tablets. The ONWASA central lab analyzes most reported parameters for the NDMR, and field parameters are analyzed at ONWASA's Summerhouse WWTF. End Use -Irrigation Are buffers adequate? Is the cover crop type specified in permit? Is the crop cover acceptable? Is the site condition adequate? Is the site free of runoff / ponding? Is the acreage specified in the permit being utilized? Is the application equipment present? Yes No NA NE • ❑ ❑ ❑ ❑•❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 5 of 6 DocuSign Envelope ID: 859390DA-F686-4239-98A9-B11F00102270 Permit: WQ0019907 Owner - Facility:Onslow Water and Sewer Authority Inspection Date: 02/15/2023 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is the application equipment operational? Is the disposal field free of limiting slopes? Is access restricted and/or signs posted during active site use? Are any supply wells within the CB? Are any supply wells within 250' of the CB? How close is the closest water supply well? Is municipal water available in the area? # Info only: Does the permit call for monitoring wells? Are GW monitoring wells located properly w/ respect to RB and CB? Are GW monitoring wells properly constructed, including screened interval? Are monitoring wells damaged? • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • Comment: The high-level alarms at the effluent pump station, located at the plant site, were operational and the Missions telemetry system contacts the operator on -call. Effluent flows through a force main approximately 4 miles to the storage pond at the irrigation site. The ONWASA collection system staff checks this priorty line regularly as required. The fields were in adequate condition. Field 1/1D was never constructed. The 13.3 MG storage pond is lined and the berm was in good condition. Freeboard was between 3-4 feet. The irrigation pump station is monitored by the Missions system. Page 6 of 6