Loading...
HomeMy WebLinkAboutNC0085952_Issuance of Permit_20101110 ��s NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary November 10, 2010 James Schenker, Environmental Associate TravelCenters of America 24601 Center Ridge Road Suite 200 Westlake,Ohio 44145-5634 Subject: Issuance of NPDES Permit No. NC0085952 Candler Travel Center WWTP Buncombe County Dear Mr. Schenker: Division personnel have reviewed and approved your application for renewal of the subject permit. Accordingly, we are forwarding the attached NPDES discharge permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). During the past five year permit cycle there have been numerous incidents of noncompliance. Consistent and reliable operation of this site will allow the facility to reduce/eliminate the occurrence of these noncompliance events and maintain compliance with the permit. Request tp increase BOD-5 day limits on NPDES NC0085952 dateddJuly 13, 2010: It is standard DWQ policy to leave BOD5 limits unchanged for minor permit renewals, including dischargers to zero-flow streams (your facility discharges to a zero flow stream). However, BOD limits could change for reasons listed below: • Instream data indicates actual or potential exceedances of the water quality standard for dissolved oxygen. • The facility proposes to expand (new flow). • The facility proposes a change in discharge location. Since none of these scenarios is being proposed, your request is denied. This final permit contains no changes from the Draft permit mailed to you on September 15,2010. If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty(30)days following receipt of this letter. This request must be in the form.of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings (6714 Mail Service Center, Raleigh, North Carolina 27699-6714). Unless such demand is made, this decision shall be final and binding. 1617 Mail Service Center.Raleigh.North Carolina 27699-1617 Location:512 N.Salisbury St.Raleigh.North Carolina 27604 One Phone:919-807-6387 1 FAX:919-807-64951 Customer Service:1-877-623-6748 NorthCarol ina Internet:http:Oportal.ncdenr.org/web/wq/home NaturallyAn Equal Opportunity 1 Affirmative Action Employer • If you are no longer the contact person for this facility please complete the attached form with the new contact person's information, and return the completed form as soon as possible. Please note that this permit is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the permit. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources,the Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Bob Guerra at telephone number(919)807-6387 or email at (bob.guerraancdenr.aov). Sincerely, # 1:::::::: n H. Sullins .cor Enclosure:NPDES Permit NC0085952 Ownership/Contact name change form cc: NPDES Unit Central Files Asheville Regional Office/Surface Water Protection (Roger.Edwardst ncdenr.00v1(ecopy) Technical and Assistance Certification Unit—(James.Puoh(cD_ncendr.aov)(ecopy) James&James Environmental Management, Inc. PO Box 519 Mountain Home,NC 28758 • 1617 Mad Service Center,Raleigh,North Carolina 27699-1617 Location:512 N.Salisbury St.Raleigh,North Carolina 27604 One Phone:919-807-63871 FAX:919-807-64951 Customer Service:1-877-623-6748 NorthCarolina Internet http://portai.ncdenr.org/webAvyhome An Equal Oppatuniy 1 Affirmative Action Employer fi/'J,l/'atura/I ji • Permit NCOQ85952 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provisions of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, TA Operating, LLC is hereby authorized to discharge wastewater from a facility located at the Candler Travel Center WWTP 153 Wiggins Road Candler Buncombe County to receiving waters designated as an unnamed tributary to George Branch in the French • Broad River Basin in accordance with effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, Ill and IV hereof. This permit shall become effective December 1, 2010. This permit and authorization to discharge shall expire at midnight on October 31, 2015. Signed this day November 10, 2010. Coleen H. Sullens, Director Division of Water Quality By Authority of the Environmental Management Commission Permit NC0085952 SUPPLEMENT TO PERMIT COVER SHEET All previous NPDES Permits issued to this facility, whether for operation or discharge, are hereby superseded and, as of this issuance, any previously issued permit describing this treatment facility or bearing this number is no longer effective. Therefore, the exclusive authority to operate and discharge from this facility arises under the permit conditions, requirements, terms, and provisions described herein. TA Operating, LLC is hereby authorized to: 1. Continue to operate an existing 0.025 MGD extended aeration wastewater treatment plant consisting of the following treatment components: • 6,260- gallon aerated equalization basin • Bar screen • Flow splitter box • 31,250-gallon aeration basin configured in two trains • Dual secondary clarifiers • Dual cell (dual media) tertiary filtration system • 530-gallon chlorine contact tank • Dechlorination • 3,800-gallon sludge holding tank • Standby power supply 2. This facility is located at the Candler Travel Center WWTP, 153 Wiggins Road, Candler, in Buncombe County. 3. Discharge from said treatment works, through outfall 001, into an unnamed tributary to George Branch, Class C water in the French Broad River Basin, at the location specified on the attached map. -I ‘v\,.._....7.."?- J T11 'fap, /%f t sc�l��_ figiN -- - 2 . Altir - ' 1( fr r • r a fiC? \\11 (1111111 • !f \\ '7 ; ‘3) \ r ‘411.14 4- . j / -e• • II\ \ , 0), / . . il • \1 r .+' filL Outf.> • „ miar —m% au a i "pe:.11 all 0017<:14"(0111 le . ( onl V' ____, • „,,,,,,,. /' A i 4 A -- .,. - iv era __ . f w ....;,---. _-\.- • ir4 .in , .., . 1-10----104,VM.— 3,.,-- -:1.2.# 74 ( 4 ,.....411--- .„.„,....---- .-.7r.. .' -- 141 . \111 fcc a a ■ h _�____ 'IliNFoa 35. 'ass � o .// - Q44,11 dt - 1 .f .11 R',, .ter. o - I. fir. ,...1.41:,kil 15 �, :TN., 'i - 1:9:,,_:"C‘, ..N‘...V-.•-• -. I Creek 011)..7*):" •7 "--.. -- ` a cCI ."" Filer ..../.... 1. . .,---,-------:\\r2,7 L.? . /- • II iigv- ./. il r.---..._.... „... .....,Thil, i r,n , 7,----%-'4\,...1r_.„---\Th ..-----Z) c-- ,, TA Operating Corporation Facility I Candler Travel Center WWTP Location Latitude: 35°32'03" N State Grid: Canton not to scale Longitude: 82°45'05" W" Permitted Flow: 0.025 MGD Receiving Stream: UT to George Branch Stream('lass: C North NPDES Permit No.NC0085952 NorDrainage Basin: French Broad River Basin Sub-Basin: 04-03-02/06010105 Buncombe County Permit,NC0085952 A. (1.) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS During the period beginning on the effective date of this permit and lasting until expiration, the Permittee is authorized to discharge from outfall 001. Such discharges shall be limited and monitored by the Permittee as specified below: EFFLUENT MONITORING REQUIREMENTS CHARACTERISTICS Monthly Daily Measurement Sample Type Sample Location Average Maximum Frequency 50050 Flow 0.025 MGD Weekly Instantaneous Influent or Effluent 00310 -BOD, 5-day(20°C) 5.0 mg/L 7.5 mg/1 Weekly Composite Effluent (April 1 —October 31) 00310-BOD, 5-day(20°C) 10.0 mg/L 15.0 mg/L Weekly Composite Effluent (November 1 —March 31) 00530-Total Suspended Solids 30.0 mg/L 45.0 mg/L Weekly Composite Effluent 00610-NH3 as N 2.0 mg/L 10.0 mg/l Weekly Composite Effluent (April 1 —October 31) 00610 -NH3 as N 4.0 mg/L 20.0 mg/1 Weekly Composite Effluent (November 1 —March 31) Effluent, 00300-Dissolved Oxygen' Weekly Grab Downstream2Upstream& I31616-Fecal Coliform (geometric mean) 200/100 ml 400/100 ml Weekly Grab Effluent 50060-Total Residual Chlorine3 17 ug/I 2/Week Grab Effluent 00010-Temperature(°C) Effluent, Weekly Grab Upstream& Downstream2 00400-pH Between 6.0&9.0 s.u. Weekly Grab Effluent Footnotes: 1. The daily average dissolved oxygen effluent concentration shall not be less than 6.0 mg/L. 2. Upstream=at least 100 feet upstream from the outfall. Downstream=at least 300 feet downstream from the outfall. 3. The Division shall consider all effluent TRC values reported below 50 ug/L to be in compliance with the permit. However, the Permittee shall continue to record and submit all values reported by a North Carolina certified laboratory (including field certified),even if these values fall below 50 ug/L. There shall be no discharge of floating solids or visible foam in other than trace amounts. Guerra, Bob From: Frazier, Wanda [wanda.frazier@ncdenr.gov] Sent: Wednesday, October 13, 2010 4:34 PM To: Bob Guerra Cc: Edwards, Roger Subject: NC0085952 Draft permit 2010 Attachments: image001.gif; image002.gif; NC0085952 Candler Travel Ctr 2010.pdf; 85952 a cover page 2010.doc; NC0085952 12-30-10.pdf; NC0085952 12-19-08.pdf; NC0085952 12-11-07.pdf; NC0085952 11-13-07.pdf Hi Bob, Everything looks good. I met with the contract operator and did an inspection on 12-30-2010. Attached are the 4 most recent staff reports and most recent facility info cover page(2010). Here's what I would suggest. Supplement to permit cover page: (see attachment) Continue to operate: 0.025 MGD extended aeration package plant consisting of: three grease interceptors with 6 portholes; 6,250 gallon concrete flow equalization basin; manual bar screen; flow splitter box;31,250 gallon aeration basin, configured in two trains,with dual blowers providing diffused air;dual 75 sq ft rectangular clarifiers; dual cell, multi-media (downflow)tertiary filtration system with mudwell and clearwell;3,800 gallon aerobic digestor; 530 gallon chlorine contact tank with tablet chlorinator;tablet dechlorinator; and standby emergency generator. Permit limits page: The draft permit and cover page indicate that the semi-annual monitoring for Oil and Grease have been eliminated. This facility has three grease interceptors with 6 portholes and is pumped quarterly. They do a very good job of taking care of these tanks, as there are no FOG problems at this facility. ARO concurs with the removal of O&G monitoring. There has been a request to increase the BOD&TSS limits to 30/30. Stream information: Stream &river basin: UT to George Branch; French Broad River Basin Sub-basin: 04-03-02 Quad: Canton Grid: Stream classification: C Drainage area sq mi: 1 Instream Waste Conc.: Average stream flow: Summer 7Q10 cfs: Winter 7Q10 cfs: I am missing some of the stream information data, and cannot comment on this. Please send me the model data and calculations, if you have it, and let me know if the limits can be increased. Development: The renewal application did not reflect everything that was on-site. It consists of a commercial convenience store,gas station,tire service/repair garage, restaurant, and rest rooms with showers. Permittee: Jim Schenker's(Environmental Associate) last day is 10-14-2010,therefore, please put the permit in the name of: Responsible official: David A. Plummer Responsible "'s title:, Senior Environmental Associate Mailing address: TA Operating Corporation 24601 Center Ridge Road,Suite 200 Westlake, Ohio 44145-5634 (I called and talked to David Plummer about this.) Summary: I feel that everything else in the attached documents is accurate. ARO recommends renewal of this permit. Let me know if you have questions or comments. Thanks, Wanda Wanda Frazier Email: Wanda.Frazier@ncdenr.gov North Carolina Department of 2 • ASHEVILLE CITIZEN TLVIES VOICE OF THE MOUNTAINS•CmzEN-TIMFs.com AFFIDAVIT OF PUBLICATION Nodal North Caro°�vIy�rrpo�,n�� t kn�nt BUNCOMBE COUNTY 161 ullr vice Center u,u: �NC 1769.1617 Ss. ..i.;= Intent to!esus _. , J NPDES Wastewater The North Carolina Environmental Management NORTH CAROLINA Commis Ion proposes to issue a- NPDEES5 waste- water discharge permit to the persons) listed below. , • Written comments r�ardln the propose- Before the undersigned, a Notary Public of said County and m�ttut will be accgpted tTnNl 38 dgys after h et - It date of thus notice. The Director oft NC DI torI of Water Quality DWQ) ma, hod a pub is nearing should there be a sl ni cant de State, duly commissioned, qualified and authorized by law gree ofr publlc interest. Please mal comme is and/or In;nrmation requests to DWQ at the to administer oaths, personally appeared Anne Gardner, above address. Interested persons may v sit the DWQ a 5512 N. Sae(isbu Street, Raleigh, NC to review lnformPDgSatlon permn5 Kieari. Addthisitionon i Infor• who, being first duly sworn, deposes and says: that she is gittyorg.o byn calIiinp(9 9,807-6304. "`"`r"nl�equam�� the Legal Billing Clerk of The Asheville Citizen-Times, o pen b� P 1681ues k r esrtil ob new I engaged inpublication of a newspaper known as The ofaeperWmiWt rNC 1B5u2 co F en'S nttyn;M s per- glItTed dixharge is"treated domesi wastewa Asheville Citizen-Times, published, issued, and entered as ter to Flat Creek.French Broad River Basin. Bertha s• Bumett� request ne ni of per" second class mail in the Cityof Asheville, in said County Bunco be Vega s matte ton in died bdortteRiv twhelsgtapwe to ekteto dischargeeek and State; that she is authorized to make this affidavit and French Broad Rlveer Basun. The Buncombe County Board Of Education re- sworn statement; that the notice or other legal nested renewal of gg rrnit NC0061182 for the quested BC com a Ulla p�r„ottot'ad` discharge uis n- advertisement, a true copy of which is attached hereto, was treated waste ater to Stanfield Branch in the French BroadRlverBasin. published in The Asheville Citizen-Times on the Ledgestone Nome Dw rs Association request- ed renewal 0f permit N 556 r the Ledges- followingdate: September 17, 2010. And that the said tone Subdivision WWTP Buncombe County; P this permitted discharge is steel domesti wastewater to Cane Creek in the French Broad newspaper in which said notice, paper, document or legal River Basin. TA Travel Centers• LLC, nested renewal of advertisement was published was, at the time of each and rmit. NC0085952 for Cantil r Travel Center pWew�7P in Buncombe County; tnls permitted dis- everypublication, a newspaper all of the charge is treated dpmestic w 5tewater to a UT meeting to George Branch.French Broad River Basin. Navon Inc. requested renewal of rmit requirements and qualifications of Section 1-597 of the Buncombe Cou ty athls permittedmdischa qe is General Statues of North Carolina and was a qualified treated domestic wastewater to Pole Creek, French Broad River Basin. newspaper,within the meaning of Section 1-597 of the • B "renew County Bland 0 Educ tion e4 uest- BuncCombe l Element9 t N chool r the DBun- General Statues of North Carolina. combe County; this amnio WING IInarg Bun- treated wastewater tope Dick Branchh Ind the French Broad River Basin. NCi t WatefrorlLC reoirst�d renewal of permit the Rapids at French Broad WWTP in Buncombe County; this permitted a- duity discharge treated wastew�t�r to French Broad River in the ileh Broad River Signed this 17th day of September, 2010. Basin. September 17,2010 (7716) (11t..40,17 (Signature of person making affidavit) Sworn to and subscribed before me the 17th day of September, 20,10. (..... .iceie'- . - - ai -i;---) (Notary P blic) ,,........•• My Commission expires the 5th day of October, 2013. .`•4. •AOYE�,,C':, (828)232-5948 I (828)253-5092 FAX ;' NC r ,:�, I(� 14 O. HENRY AVE. I P.O. BOX 2090 I ASHEVILLE,NC 28802 I (800)800-4204 CGAMffIT Po€3.. o Compliance Issues: French Broad River Basin NC0085952 TA Operating Corporation —Candler Travel Center Most violations at this facility have been attributed to deficient operation practices by the former operator. Since a new ORC has been hired, the frequency and magnitude of limit violations has dropped. No permitting initiative is deemed necessary to address noncompliance. The permit writer may wish to consider adding language to the cover letter citing noncompliance during the previous permit cycle, and noting the importance of consistent,reliable operation of this system in order for it to remain in compliance. NC0061182 North Buncombe High School Facility has experienced effluent limit violations leading to civil penalties for fecal coliform, total suspended solids and whole effluent toxicity. TSS violations may be associated with flaking of the tablets used for dechlorination.Toxicity issues may merit special attention. Technical assistance has been performed at the WWTP and cleaning products have been inventoried. The permit requires ammonia monitoring,but the permit has no ammonia limit. The permit writer should examine ammonia data in relation to tox test failures to see if there is any obvious connection.Dechlor chemical concentrations may also be a suspect in toxicity matters. ATU has not specifically weighed in on this situation. If chlorination/dechlorination appears to be a problem,the facility may be encouraged to go to a UV system for disinfection. Additionally, increasing the ammonia monitoring frequency from 2/month to weekly may be advisable. At a minimum,the cover letter should include language pointing out the toxicity issues. Should noncompliance continue, the facility may want to begin to evaluate the feasibility of connecting to the MSD Buncombe collection system. NC0075388 Havon, Inc. —Pleasant Cove Home WWTP Most noncompliance was closer to beginning of last permit cycle. Recent months show much improved performance. The permit writer may wish to consider adding language to the cover letter citing noncompliance during the previous permit cycle,and noting the importance of consistent, reliable operation of this system in order for it to remain in compliance. NC0036641 Fletcher Academy WWTP Most noncompliance from earlier in last permit cycle. Facility experienced ammonia violations Feb. —Apr. 2009; in compliance through most recent reports received. The permit writer may wish to check BIMS for most recent compliance information and contact ARO for any recent developments. At the present time, this facility is not seen as a problem facility. You may consider adding language to the cover letter citing noncompliance during the previous permit cycle, and noting the importance of consistent, reliable operation of this system in order for it to remain in compliance. Compliance Issues: French Broad River Basin NC0020290 Town of Burnsville WWTP The facility had some major upset episodes during the last permit cycle that were partially due to long term neglect of routine O&M. The Town has also had pretreatment and collection system concerns. The facility has recently undergone a number of upgrades that have led to much improved performance. The cover letter may wish to note these upgrades and the need for continuing attention to O&M in order to maximize treatment potential. NC0067342 North View Mobile Home Park This facility looks ok based upon the values submitted on DMRs,but typically does not look as good during inspections. The WWTP has been the subject of numerous complaints from neighbors. The permit writer is asked to contact ARO during permit development process to see if any new issues have arisen that may require treatment within the permit. NC0066788 Buncombe Co. BOE—Fairview Elementary School 2009 annual average for flow was 91.78% of design capacity. NC0086436 Buncombe Co. BOE—Cane Creek Elementary School 2009 annual average for flow was 82.85% of design capacity. 10/07/2010 11:50 FAX 16002 At.4 •S,', JAMES & JAMES ENVIRONMENTAL MANAGEMENT, INC le ` vA PO BOX 519, MOUNTAIN HOME, NC 28758 i\�: eigs0�7 (828)6970063 OFFICE titan (828)697-0065 FAX July 13,2010 Permit Renewal Bob Guerra 1617 Mail Service Center Raleigh,NC 27699— 1617 Re: Travel Centers of America NPDES N00085952 Dear Mr. Guerra, It is the time for the Permit to be renewed for the TA Centers, dba Candler Travel Center. The limits for this facility are lower than those of other systems entering into the same stream. The discharge enters the unnamed tributary of Georges Branch. We request that the limits for the BOD-5 day be increased to 30/45 mg/I. With this increase,and the improvements that have been made to the facilities air flow, we maintain that the facility would be able to remain in compliance more consecutively. We,then as now, would always to strive to maintain the optimum quality of effluent from the facility as possible with the ultimate goal to be none detected. We would appreciate your consideration in this matter. Thank you, qtx-e,t) Harry&Juanita James TravelCenters of America TA . . James J.Schenker Environmental Associate 24601 Center Ridge Road,Suite 200 Westlake,Ohio 44145-5634 440/808-7368 440/808-3307(facsimile) schenker jim@tatravelcenters.corn March 11, 2010 Ms. Dina Sprinkle NCDENR/DWQ/Point Source Branch 1617 Mail Service Center Raleigh, NC 27699-1617 Re: Candler Travel Center NPDES Permit No. NC0085952 Permit Renewal Dear Ms. Sprinkle: This letter is being provided to the Division of Water Quality (DWQ) in regard to the February 23, 2010 NPDES Renewal Notice received by TravelCenters of America (TA). I have enclosed the completed permit renewal application (Form D) for the above referenced facility. Sludge from the wastewater treatment plant is disposed of at the local municipal wastewater treatment plant. Additional detail on sludge disposal method has been detailed by our plant operator, James and James Environmental Management, Inc., and enclosed in this submittal. If you have any questions concerning this, please do not hesitate to contact me. Respectfully submitted, im Schenker Environmental Associate Enclosures cc: Enfos Database Ms. Terry Storey -James and James Environmental Management, Inc. NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD Mail the complete application to: N. C. DENR / Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit'NC00$9159: If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise,please print or type. 1. Contact Information: xX rName -rA oferca-IncxLLL Facility Name cndilf Mailing Address 1-4100i £1—J -- V €A.. City State / Zip Code 6 N 11+5 Telephone Number (t.. $Q - 7%g- Fax Number ( yyo) fag- 330-7 e-mail Address CcrNes•ko... ; me (we les_AkefS• C 2. Location of facility producing discharge: Check here if same address as above ❑ Street Address or State Road 16 j W i Cn 4 n S R O0. City C-0.r1ckk 2.-C 1 State / Zip Code N c_ as-/i5 County UU fl C e'en 2_ 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) ■■►t Name �0.tW2g�--3o dKg_g ��foJiMAs .9. M0.riAl eimszA-t Mailing Address - O /35471 City M Don,-177).n 1JO?'1 e.- State / Zip Code ge- a$15 - - Telephone Number (ga8) 617 -0063 IPE C 15 0 Fax Number ( gag) 697 - 006 MAR 15 2010 DENR-wr TER OtjA!_Ty POINT tits:-.,BCH 1 of 3 Forth-D 05/08 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 4. Description of wastewater: Facility Generating Wastewater(check all that apply Industrial 0 Number of Employees Commercial air Number of Employees .Y Residential 0 Number of Homes School ❑ Number of Students/Staff Other ❑ Explain: Describe the source(s) of wastewater (example: subdivision, mobile home park, shopping centers, restaurants, etc.): RS-Eaur'are:-(✓ 4,�rhr:ro-K-5 , shokJe'iS Population served: l-j-r9h.W2y142" 5. Type of collection system Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points / Outfall Identification number(s) G17 I Is the outfall equipped with a diffuser? ❑ Yes %No 7. Name of receiving stream(s) (Provide a map showing the exact location/ of each outfall): OY�n aro•z( h bu f-ar0.- I 6e 'cy e7. /era to Pea eA arias/4 iter- 8. im Basi z. 8. Frequency of Discharge: Continuous ❑ Intermittent If intermittent: Days per week discharge occurs: Duration: 9. Describe the treatment system List all installed components, including capacities,provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet of paper. a a 25 1165 (A)L TP, �,aso (k//&� a€ra�f--eai in c/uev zpea/ao-/ t ba5irl. bar screen f /G.11 s/0/4/et"f 3 I;a sc 11,7 a#!2/i'/L b a si/L 4.0447 vred / vo -ir'airc 5 l doe,/ 15 4}- _Secondar"y c/ar'.6,e.S/ civet" e e/1 C44,/ ed&) Jerle417 fr Prot y S.&e 530 74 //a,i ek lop;,, cvr-f4zc-4 fie c/ Iorerza-Iron_ u , FOG 9a.lion 2 of 3 Form-D 05/08 4 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 10. Flow Information: Treatment Plant Design flow 0.025 MGD Annual Average daily flow 0.003 MGD (for the previous 3 years) Maximum daily flow 0.co 8 MGD (for the previous 3 years) 11. Is this facility located on Indian country? ❑ Yes M No 12. Effluent Data Provide data for the parameters listed. Fecal Coliform, Temperature and pH shall be grab samples,for all other parameters 24-hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. Parameter Daily Monthly Units of Maximum Average Measurement Biochemical Oxygen Demand (BODS) 2-/, , -7 2. 6 /L Fecal Coliform ), I /AO ML Total Suspended Solids , .1 8 . .a P-1&/Z._ Temperature (Summer) a6. 7 Temperature (Winter) 6 j- 6 6G pH 7.7 7. 1/ 13. List all permits, construction approvals and/or applications: Type Permit Number Type Permit Number Hazardous Waste(RCRA) NESHAPS (CAA) UIC(SDWA) Ocean Dumping(MPRSA) NPDES ;JCc o8.5?5a- Dredge or fill(Section 404 or CWA) PSD (CAA) Other Non-attainment program (CAA) 14. APPLICANT CERTIFICATION I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. �C►mes n f Envirwnmt.eta kssocioke..._ Printed name of Person Signing Title .41111111, ////1c' ture o 'pplic. Date N. Carolina General Statute 143-215.6(b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record,report, plan,or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article,shall be guilty of a misdemeanor punishable by a fine not to exceed$25,000,or by imprisonment not to exceed six months,or by both. (18 U.S.C.Section 1001 provides a punishment by a fine of not more than$25,000 or imprisonment not more than 5 years,or both,for a similar offense.) 3 of 3 Form-D 05/08 • . !,1" vt 9 � ����� James & James Environmental Management, Inc. 4t, 1V� 3801 Asheville Hwy.,Hendersonville, N.C. 28791 ,41k OFFICE:(828)697-0063 FAX: (828)697-0065 March 11, 2010 N. C. Department of Environment and Natural Resources Division of Water Quality/NPDES Unit 1617 Mail Service Center Raleigh,N. C. 27699-1617 Regarding All Waste Water Facilities Operated by James&James To Whom It May Concern: Sludge from this facility(Candler Travel Center)is pumped by Mike's Septic Tank Service and is permitted to be dumped at Brevard Waste Treatment System and MSD. Sincerely U OJ Juanita mes James and James Environmental Mgt., Inc. FACT SHEET FOR EXPEDITED PERMIT RENEWALS This form must be completed by Permit Writers for all expedited permits which do not require full Fact Sheets. Expedited permits are generally simple 100%domestics(e.g., schools,mobile home parks,etc)that can be administratively renewed with minor changes,but can include facilities with more complex issues(Special Conditions, 303(d)listed water,toxicity testing, instream monitoring,compliance concerns). Basic Information for Expedited Permit Renewals Permit Writer/Date Bob Guerra/8-5-2010 Permit Number NC0085952 Facility Name Candler Travel Center WWTP Basin Name/Sub-basin number French Broad—04-03-02 Receiving Stream UT to George Branch Stream Classification in Permit C ` Does permit need Daily Max NH3 limits? No Does permit need TRC limits/language? Yes If Yes,add TRC language below Does permit have toxicity testing? No Does permit have Special Conditions? No Does permit have instream monitoring? Yes Data reviewed /No impacts noted Is the stream impaired(on 303(d)list)?For No what parameter? Any obvious compliance concerns? Most violations have been attributed to the deficient operations practices by the former ORC. Since a new ORC has been hired,the frequency and magnitude of limits violations has dropped. No permitting initiative is deemed necessary to address non compliance. Any permit mods since last permit? NO Current expiration date October 31,2010 New expiration date October 31,2015 Comments received on Draft Permit? Yes No Most Commonly Used Expedited Language: • 303(d)language for Draft/Final Cover Letters: "Please note that the receiving stream is listed as an impaired waterbody on the North Carolina 303(d)Impaired Waters List. Addressing impaired waters is a high priority with the Division,and instream data will continue to be evaluated. If there is noncompliance with permitted effluent limits and stream impairment can be attributed to your facility,then mitigative measures may be required". • TRC language for Compliance Level for Cover Letters/Effluent Sheet Footnote: "The facility shall report all effluent TRC values reported by a NC certified laboratory including field certified. However,effluent values below 50 ug/1 will be treated as zero for compliance purposes." Reminder:Permits that are not subject to expedited renewal include the following: 1)Major Facility(municipal/industrial);2)Minor Municipals with pretreatment program; 3) Minor Industrials subject to Fed Effluent Guidelines(lb/day limits for BOD,TSS,etc);4) Limits based on reasonable potential analysis(metals,GW remediation organics);5) Permitted flow>0.5 MGD(requires full Fact Sheet); 6)permits determined by Supervisor to be outside expedited process. Note:This sheet is located on NPDES Server/CurrentVersions/Expedited Fact Sheet May2010