Loading...
HomeMy WebLinkAboutWQ0044048_Application (FTSE)_20221221DWR l44- wept of Lnvirortmental Quality State of North Carolina Department of Environmental Quality Division of Water Resources DEC 2 l FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources Raleigh Regional Offic(fTA 06-21 & SUPPORTING DOCUMENTATION Application Number: aU� q q040— (Io be completed by DWR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: 1. Applicant's name: Town of Benson (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/County ® Municipal 3. Signature authority's name: Kimberly Pickett per 15A NCAC 02T .0106Lh] Title: Town Manaaer 4. Applicant's mailing address: P.O. Box 69 City: Benson State: NC Zip: 27504-0069 5. Applicant's contact information: Phone number: (919) 894-3553 Email Address: kpicketta,townofbenson.com I1. PROJECT INFORMATION: ❑ Privately -Owned Public Utility ❑ Other 1. Project name: Mingo Creek Interceptor and Sewer System Improvements— Phase 1 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: , For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Johnston 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.369115 , Longitude:-78.5514.34 5. Parcel ID (if applicable): 153919-50-5815 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Peter. Galan License Number: 49347 Firm: The Wooten Company Mailing address: 120 N. Boylan Avenue City: Raleigh State: NC Zip: 27603-1423 Phone number. (919) 828-0531 Email Address: clan thewootencom an .com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Benson Wastewater Treatment Facility Permit Number: NCO020389 Owner Name: Town of Benson V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQCS00109 2. Downstream (Receiving) Sewer formation: 12 inch M Gravity Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00109 Owner Name(s): Town of Benson FORM: FTA 06-21 Page I of 5 Vl. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑ No ® NIA 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement 4FORM: DEVJ been attached? [—]Yes [:]No ®NrA 3. If the Applicant is a Home/Property Owners' Association, has an HQA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.01 15(c) been attached? [—]Yes [:]No ®NtA 4. Origin of wastewater: (check all that apply): ❑ Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparationlservice ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ® Businesses / offices + factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater : % Domestic % Commercial .100 % Industrial See 15A NCAC 02T .0103J20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .0114? ❑ Yes ® No ➢ If yes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a,b No. of Units Flow gal/ GPD gall GPD gall GPD gall GPD gall GPD gall GPD Total 0 GPD a See 15A NCAC 02T.01 14(b), (d), (e)[ 1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T.01 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 14) shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .01 14) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ® Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC(Gravity Sewers): I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 12 215 PVC ... 71 D Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC Y111. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): . . gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 8 2,705 PVC If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01 C. I.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1_): ❑ Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B), ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06 21 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): I. Does the project comply with all separations/alternatives found in 1.5A NCAC 02T .0305(f) &_(A)? ® Yes ❑ No 15A NCAC 02T.0305 contains minimum separations that shall bejpyovided for sewers stems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 2Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 'Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet "Any private or public water supply source, including any wells, WS-I waters of Class I or Class 11 impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet i 50 feet "Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0345(f).or (, see Section X.1 of this application *15A NCAC 02T.0305(g contains alternatives where separations in Q2T.0105ib cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. "Stream classifications can be identified using the Division's NCSurface Water Classifications weboaS 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ NIA ➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ❑ Yes ❑ No ® NIA ➢ Please provide supplementary information identifying the areas of non conformance. ➢ See the Division's draft station requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Neuse ❑ No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ➢ This includes Trout Buffered Streams per 15A_NCA 202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with LSA NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per I $A NCAC 02T.0I05(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of.Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the VariancelAlternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects„requiring, a variance approval may be subject to longer review times. For proJects requirinp, two or more variances or where the variance is determined by the Division to be a significant portion of the proiect, the full technical review is required. 2. Professional Engineer's Certification: 1, kyK NX - 6moy , attest that this application foryW60 Q&�f LA ff f ;twk SYstm vw0whol (Professional Engineer's name from Application Item 111.1.) (Project Name from Application Item 11.1) , ""W has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, I specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criterias for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permittjn of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) .... _- ......... _............ ..... . ... ......, North Carolina Professional Engineer's seal, signature, and date: ��� �(N CARD /�i S S r i .O 'GINS' € .............. ..................................... .................... 3. Applicant's Certification per 15A NCAC 02T .0106(b): 1, 1`1\YVll Wuj' -T i 1Ctb-� attest that this application for '(( & � We( S Iem (Signature Authority Name from Application Item 1.3.) (Pr ect Name from Application Item 11.1) `mh�y�lChli pna�c. z- attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-20.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. SignDate: 2 FORM: FTA 06-21 Page 5 of 5 X% ooten December 21, 2022 Reviewer Raleigh Regional Office Water Quality Section 3800 Barrett Drive Raleigh, NC 27609 NC Dept of Environmental Quality DEC 21 DO Raleigh Regional Office Subject: Sewer Fast Track Application Mingo Creek Interceptor and Sewer System Improvements — Phase Johnston County, North Carolina TWC No.: 2293-CN Dear Reviewer: 120 N Bovlan Avenue Raleigh NC 27603 (919)828-0531 On behalf of the Town of Benson (PWS ID NC 03-51-025), we are submitting one (1) original and one (1) copy of the following documents, as well as a check for a permit fee of $480.00, related to the above referenced project for your review and approval: • Sewer Fast -Track Application (FTA 06-21) • Project Narrative (see below) • USGS Topographic Map showing proposed utilities • Aerial map showing general project area The project includes the installation of a dedicated force main for industry wastewater effluent and sanitary sewer required to connect to the Town of Benson system. The Town will install approximately 2,705 LF of 8-inch force main by open cut and dry bore and jack. The Town will also install approximately 215 LF of 12-inch gravity sewer by open cut and dry bore and jack. This force main is being installed as a dedicated force main for an existing industry; the gravity sewer installation will carry this discharge as well as wastewater discharged from an apartment complex. TheWootenCompany.colm rr' Zr ./�,-,Z y_ DESIGNING THE FUTURE - 4anoN4 Dunn, NC USGS 7.5' Map Se; e� , GRAPHIC • ■ - ; F - _ .►,,�,. ��' jC o • C r • : a• ! + a IF � �3;fit 0 ."L.••• . Y'�•,� �*}�' , • G `ti 'XP 1 N 0 f `` • iS ±n.^y. •-, yyf n • - : ,�� - ; A `Legend- 7 d Forcemain Sewer Line Fl 141 N • Ar �+ • F• � � - a.alrr ro Pm wjiz L !•±� ! tit N .Jf f ■ Y t ■ } ; y+ f p ti- s ` i Dfft • SrfP — - f'� •+ - Z42 o 722 7S*33' 7 j4 ; 72F, 76°x1'W 727000mE 1 .5 I 0 1000 2000 4000 5000 l .5 0 KILOMETERS 1 NAC83/WG584 UTM Zone 17 MILES FEET 1000 0 METERS HIM F iC16 Nat onai Geograpk c Partners. Please •-' r, n' uhge A ipr,rse.rtrttd User assumes ail risk assoc aced w,th the use of this map. • fi Paz e7_ , � —� , 2, Smith, J Chris From: Peter Galan <pgalan@thewootencompany.com> Sent: Monday, February 13, 2023 1:44 PM To: Smith, J Chris; Pickett, Kim Cc: Robinson, Jason; Kurtz, Cassidy; Dave Malinauskas Subject: [External] RE: Mingo Creek Interceptor and Sewer Improvements - Phase 1 CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Hi Chris, Thanks for the question -- glad to know y'all are making progress on the review, as busy as things are at the State review offices these days. Looking back at what we provided as the submittal package, we certainly could have been more clear in the cover letter — apologies for the lack of clarity. There was no pump station information included because the pump station to which this force main is connecting (the pump station maintained by Berry Global, the Town's industrial client that discharges flow into the Town's system) will not change from its current operational performance. No flow changes are planned as a part of this installation — the Town is implementing this project solely to enable its Chicopee Pump Station to operate more efficiently when the industry's pump station is discharging flow. The new force main is being directly connected to the existing discharge force main for the industry's pump station; the industry force main's existing connection to the Chicopee PS discharge force main will be valved off post -construction -- as such, when the project is complete all discharged wastewater from the industry will be separate from that being discharged by the Town's Chicopee Pump Station. The Town's pump station will continue to use the existing force main until the station is decommissioned in a separate, future project. Please let us know if that answers your question, and if you have others as your review continues. Thanks, Peter Galan, PE Project Engineer (919) 828-0531 x840.Office (919) 834-3589 • Fax 120 N. Boylan Ave. Raleigh, NC 27603 Wooten From: Smith, J Chris <chris.smith@ncdenr.gov> Sent: Monday, February 13, 2023 11:22 AM To: Pickett, Kim <kpickett@townofbenson.com>; Peter Galan <pgalan@thewootencompany.com> Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov>; Kurtz, Cassidy <Cassidy.Kurtz@ncdenr.gov> Subject: Mingo Creek Interceptor and Sewer Improvements - Phase 1 I{powered by Graphus1 Kimberly and Peter, Reviewing the application for this project we see that you have included force main information, but no pump station information is included. Please explain. Best, J. Chris Smith (he/him/his), M.R. Soil Science Environmental Specialist, Raleigh Regional office DWR North Carolina Department of Environmental Quality Office: (919)791-4257 Chris. smithOncdenngov EWr,t QTH CA' i+v JNA D99WIM o1 EnWrOnmMrtdl Quality Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. North Carolina's Riparian Buffer Protection Program