Loading...
HomeMy WebLinkAboutNC0036196_Pretreatment_Annual_Report_20230213Pretreatment Annual Report City of Newton 2022 McKenna Blevins Pretreatment Coordinator City of Newton 828-695-4337 Ext. 1153 mblevins@newtonnc.gov PAR 2022 Contents 1 Cover Letter 2 PPID Shee�, 3 SNC Historical Sheet K' ` ', ..1�1 Rp�rYrrativey 6 SNCR Report 7 Industrial Data Summary Form 9 Aldo 10 Wanzl TTO sheets 11 Certification Page February 13, 2023 Keyes McGee PO Box 1617 Mail Service Center Raleigh Raleigh, NC 27699-1617 Subject: PAR 2022 Dear Keyes McGee, Enclosed is a copy of the City of Newton's PAR for 2022. Please do not hesitate to contact me if you have any questions or need additional information. Sincerely, McKenna Blevins Pretreatment Coordinator City of Newton (828) 695-4337 mblevins(@newtonnc.gov Pretreatment Program Info Database printed on: 1 /19/2023 for Program Name Newton WWTP Name Clark Creek Program Approval Date 08/09/1983 Pretreatment Status Full Region MRO County Catawba DES N be Stream Information-'- IWC % at 7Q10 56.33 70`10 Flow cfs / mgd 6 / 3.88 1 Q10 Flow cfs / mgd 4.99 / 3.23 Stream Classification C Basin Number CTB35 Receiving Stream Name CLARK CREEK NP um r NC0036196 Last PAR Rec 02/11/2022 PAR Due Date03/01/2023 mercury NPDES Effective Date 08/01/2021 1631 NPDES Expire Date 07/31/2026 Current Fiscal 06/0512019 Year PCI Done required POTW is Primary WWTP TRUE Last Audit on 07/27/2021 Audit Year Nex125/26 yes Design Flow mgd 5.0000 % Design mgd is SIU permitted F1.97 Permitted SIU flow (mgd) [Pt—SIU) F0987 WWTP SIU's Program SIUs 2 HWA % LTMP IWS � SUO WWTP CIU's Program CIUs 2 date Inactive Date Next Due 10/01/2024 Date Received by DWR 09/15/2022 06/30/2015 10/24/2019 12/18/2012 01/08/2020 ' Date Approved J 08/05/2015 03/04/2020 02/11/2013 02/05/2020 Adopt Date Required Date Adopted 03/05/2013 Info in this Box from Pt Contacts Date Date Date PT Pro Attended Attended Attended Formal Name n. Prima Phonel ext Fax HWA Wkso IIIP Wksn PAR Wksn Mff T�1 11(828) 465-7400 Y• To an City Manager PC Box 550 28658 Mr. Eric Jones 1 11(828) 695-4346 1 1(828) 465-7481 11 1 1 1/22/2018 ejones@newtonnc.gov WWTP Superintendent PC Box 550 28658 Ms. McKenna Blevins jPfim 828-695-4337 11153 828-465-7481 mblevins@newtonnc.gov Pretreatment Coordinator 1P.0. Box 550 28658 10120/1993 IWS, IUPs 5/15/1989 SAR. IUPs; plus 5/26/89 Notice to Show Cause DWR Central Office Contact Pretreatment Staff DWR Regional Contact es Bell w L (� C N W. A L a C N N X � — N r A L 'O W C W N O N N L N 0 w o� L c 3v 3w A w yE X yE a d d O N L n E c N ¢ c U E C d d c f A a cy L c u y •. �o x ° ' c c g X X d w R z X X-- --- d d w 9 E c n 4 ui y � d � N j d L p 9 « « O N >� C N w N O N L E E 0 o a O > N > U m O 0 '> 0 "> a u w c A d a °u L a a 4 E a d N c N a'c: N N c E A a p o d y d U ax ❑ ❑ —y rn d O �"� N d i ul d O O u a ro U 2 r 2 O < 0 F C y Q U O a a � W c O N N • d :k � tt N 4-1 UJ � It Pretreatment Narrative 2022 City of Newton's Pretreatment Program -The Headwork's Analysis was approved on 1/19/2018. The updated HWA was received on 9/15/2022 and is waiting for state approval. -The Long Term Monitoring Plan was approved on 8/5/2015. -The Sewer Use Ordinance was approved on 2/11/2013. -The Enforcement Response Plan was approved on 2/5/2020 -The Allocation Table was last updated July 2018. -The Industrial Waste Survey was approved 3/4/2020. -On Newton's IDSF, if results are BDL, then we use Y2 DL as value. -Also, on Newton's IDSF, the pollutants Selenium and Fluoride are listed as Annual Testing Only and testing is conducted to support the requirements of the LTMP and Land Application testing. - Allocation Table: As of right now, Newton is over allocated for Silver. I have contacted our state representative and the game plan is to sample for Silver at our Influent and Effluent location for the next 12 months using the lower PQL (0.0005 mg/L). This gives us more data moving forward in our decision making. Once all the data is collected we can determine if a lower uncontrollable value can be used to increase the industrial allowable load. Clark Creek WWTP -On March 25, 2022 the WWTP experienced a spill that was estimated to be 200 gallons. A construction crew was tying in new lines for the Primary Reactor sludge pump. They confirmed that the lines were finished and the operators could conduct their work as normal. However, they failed to glue the cap back on and as a result when the operator went to pump sludge, the cap was pushed off, which caused the spill to occur. Sandbags were placed to stop sludge/water from spreading, lime was placed over the spill, and we used a VAC truck to help vacuum up the water as well. -On December 15, 2022 the WWTP grit channel overflowed with an estimate of 300 gallons. We had a little over 2 inches of rain, and flow meters were showing greater than 8 MG. The overflow was caught quickly. We throttled the influent pumps back and closed an incoming valve to the grit channel. The grit channel went back down in less than 10 minutes. We added lime to the area on the ground that was affected. - On December 24, 2022 Clark Creek W WTP had some issues with our Sot and C12lines bursting, due to the extremely low temperatures and wind chill. We were able to feed C12 all weekend, but we were without Sot until 12/26. We did get Sot working again on the morning of 12/27. However, we were still having issues with the meter working properly. We called a technician that services our meters, and he stated that the membrane in the meter was probably frozen. We placed a heater next to the meter, once thawed it started working properly. Upon analysis of the bend and weir samples they were within the parameter limits. Wanzl -Manufactures metal shopping carts and material handling equipment. -First six months — No NOV's issued. Wanzl was compliant January through June. -Second six months — No NOV's issued. Wanzl was compliant July through December. - Walk Through inspection was conducted on August 24, 2022 -Wanzl's TTO Certifications are included in this report. Special Metals -Nickel Alloy Welding Materials Manufacturing -First six months — On February 21, 2022, an NOV was issued for failure to monitor pH on 15 samples during 2021. It was brought to my attention that Special Metals did not in fact violate the IUP's monitoring requirement for pH during this time. As a result, I retracted the Notice of Violation on June 16, 2022. Special Metals remains complaint with the IUP pH monitoring requirements. -Second six months — No NOV's were issued. The company was in compliance. -Walk Through inspection was conducted on August 10, 2022 Citv of Conover The City of Newton and the City of Conover have an agreement that Newton will treat some of Conover's wastewater. The agreement was initiated because of the closing of Conover's Southeast W WTP. The City of Conover currently has 2 industries included in the waste stream that are classified as Categorical Industrial Users. -Engineered Controls and Hickory Springs. The City of Conover is the Control Authority for these industries within Conover. Permits for the SIU's and non -domestic users on Conover's Collection System discharging to Newton's Clark Creek W WTP will be based on the available loadings for the Clark Creek W WTP. Chapter 9, PAR Guidance Pretreatment Performance Summ 1. Pretreatment Town Name: City of Newton -Clark Creek W WTP 2. 'Primary" NPDES Number NC00 36196 or Non -Discharge Permit # if applicable => N/A 3. PAR Begin Date, please enter 01/01/yyyy 3. _> 1/1/2022 4. PAR End Date, please enter 12/31/yyyy 4.=> 12/31/2022 5. Total number of SIUs, includes CIUs 5. _> 2 6. Number of CIUs 6. _> 2 7. Number of SIUs with no IUP, or with an expired IUP 7. _> 0 8. Number of SIUs not inspected by POTW 8. => 0 9. Number of SIUs not sampled by POTW 9. => 0 to. Number of SIUs in SNC due to IUP Limit violations 10. _> 0 1 t. Number of SIUs in SNC due to Reporting violations 11. _> 0 12. Number of SIUs in SNC due to violation of a Compliance Schedule, CO, AO or sitnilar 12. _> 0 13. Number of CIUs in SNC 13. _> 0 14. Number of SIUs included in Public Notice 14. _> 0 15 Total number of SIUs on a compliance schedule, CO, AO or similar 15. _> 0 16. Number of NOVs, NNCs or similar assesed to SIUs 16. _> 0 17. Number of Civil Penalties assessed to SIUs 17. => 0 18. Number of Criminal Penalties assessed to SIUs 18. _> 0 19. Total Amount of Civil Penalties Collected 19. _> $ 0.00 20. Number of IUs from which penalties collected 20. _> 0 Notes: AO Administrative Order IUP Industrial User Pretreatment Permit POTW CIU Categorical Industrial User NNC Notice of Non -Compliance SIU Publicly Ooned Treatment Works Significant Industrial User CO Consent Order NOV Notice or Violation SNC Significant Non -Compliance IU Industrial User PAR Pretreatment Annual Report revised 1/2018. 1'AR PPS 2018 Pretreatment Annual Report (PAR) Significant Non -Compliance Report (SNCR) W WTP = Wastewater Treatment Plant, use separate form for each W WTP. SIU = Significant Industrial User SNC = Significant Non -Compliance PAR covers this calendar year => 2022 Control Authority=Program=Town Name => City of Newton W WTP Name => Clark Creek NPDES # _> NC0036196 A SNCR Form must be submitted with every PAR, please write "None " if you had No SIUs in SNC during calendar year NP # Pipe # Industry Name Parameter or "Reporting" SNC? ( Yes / No) for each 6-month period. Jan. - June July - Dec. 1015 1 Special Metals None No No 1015 2 Special Metals None No No 1018 1 Wanzl (Tech) None No No Attach a copy of the Division's "SIUs in SNC Historical Report" for your POTW's SIUs behind this page. Is the database correct ? Notify the Division of any errors ! Database indicates SNC history for previous years. EVERY SNC MUST be explained in the Narrative, How was, is, or will it be resolved? REPEAT SNCs are serious matters that MUST be explained in the Narrative. Form name: 11AR,SNCR,2001 Date Revised: 1/4/2001 Pretreatment Annual Report (PAR) Control Authority, Industry Industrial Data Summary Form (IDSF) Town Name -> City of Newton Name Special Metals Use separate forms for each industry/pipe WWTP Name => Clark Cree lup # 1015 Enter BDL values as < (value) NPDES # _> 7C7 7, 19 6 Pipe # I 1st 6 months, dates => 1/l/2022 to 6/30/2022 2nd 6 months, dates => 7/l/2022 to 12/31/2022 Total # of samples -> * Maximum (mg/1) _> * or Maximum (lb/d) _> * or Average (mg/1) _> * or Average Loading (lb/d) _> % violations,(chronic SNC is >= 66%) _> % TRC violations, (SNC is >= 33 %) _> Total # of samples => * Maximum (mg/1) _> * or Maximum (lb/d) _> * or Average (mg/1) _> * or Average Loading (lb/d) _> violations, (chronic SNC is >= 66%) _> % TRC violations, (SNC is>= 33 %) _> Total # of samples => * Maximum (mg/1) _> * or Maximum (lb/d) _> * or Average (mg/1) _> * or Average Loading (lb/d) _> % violations, (chronic SNC is >= 660/,) _> % TRC violations, (SNC is >- 33 %) _> w, mga Dulto 1 1140 Ammonia st 0 months 2nc[Omontris IstOmonths n mon s s mon s TriclOmontlis I st months 2nd 0 months 2 2 2 2 2 2 2 2 0.0075 0.00736 220.9 109.1 228 112 16.1 11.1 12.5019 6.3774 12.9037 6.547 0.9112 0.6489 0.00714 0.00718 149.4 99.4 143 94.5 10.8 9.6 8.6876 5.94 8.266 5.635 0.6292 0.5750 NA NA 0% 0% 0% 0% 0% 0% NA NA 0% 0% 0% 0% 0% 0% rsent a mmm rommm st nt s n mont s st o n t mons on s mt Not Required 1 I Not Required 2 2 Per Permit 0.001 0.001 Per Permit 1012 342 0.00006 0.00006 57.246 19.9624 0.001 0.001 726 274 0.00006 0.0006 42.386 16.3155 00/. 0% 00/. 0% 0% 0% 0% 0% opper yam a ea ercury st months n months st months n months st months n months st months n Moms 1 1 Not Required 1 l Not Required 0.169 0.093 Per Permit 0.005 0.005 Per Permit 0.00956 0.0 557 0.00028 0.0003 0.169 0.093 0.005 0.005 0.00956 0.0057 0.00028 0.0003 0% 0% 0% 0% 0% 0% 0% 0% BDL => Below Detection Limit mg/I => milligrams per liter * POTW must enter at ]cast one of these IUP => Industrial User Permit Ib/d => pounds per day four rows, Please indicate how averages were calculated SNC => Significant Non -Compliance mgd => million gallons per day Avg period could be month, Go, or 6-month & if BDL , 1/2BDL or zero values used. TRC => Technical Review Criteria W WTP => wastewater treatment plant Chapter: PAR Guidance Pile name: skelYNAB, pages 12, 13, 14 Blank IDSP Form, Copy and use in your PAR Number each set for each IUP pipe - Page of Pretreatment Annual Report (PAR) Industrial Data Summary Form (IDSF) Use separate forms for each industry/pipe Total # of samples —> * Maximum (mg/1) _> * or Maximum (lb/d) _> * or Average (mg/1) _> * or Average Loading (lb/d) _> % violations, (chronic SNC is >= 66%) _> % TRC violations, (SNC is >= 33 %) _> Total # of samples => * Maximum => * or Minimum => % violations, (chronic SNC is >= 66%) _> % TRC violations, (SNC is >— 33 %) _> Total # of samples => Maximum (mg/1) _> or Maximum (lb/d) _> or Average (mg/1) _> or Average Loading (lb/d) _> violations, (chronic SNC is >= 66%) _> % TRC violations, (SNC is >= 33 %) _> Industry Name Special Metals IUP # 1015 Pipe # I . r5,rurraalcx����.rar>rtcx�rrrrrrmllx����.rm�llx�nrr[.rurrilx����.s�rrrilx� . . 1011�111L� ar�rrarrrra 111110 s,a�a W.. . tslll�rrrr� am� rrrr� Hr�rrlrrrsrsaa 1]39�rrlrLr BUL => Below Detection Limit mg/I —> milligrams per liter * POTW must enter at least one of these ]UP => Industrial User Permit Ib/d => pounds per day four rows, Please indicate how averages were calculated SNC => Significant Non -Compliance mgd => million gallons per day Avg period could be month, Qtr, or 6-month & if BDL , 1/2BDL or zero values used. TRC —> Technical Review Criteria W WTP => wastewater treatment plant Chapter: PAR Guidance Nile name: Pi dGbgdfilhctsRediliisrnd&h*tuSLWstcl1 MB, pages 12, 13, 14 Blank IDSF Form, Copy and use in your PAR Number each set for each IUP pipe -Page of Pretreatment Annual Report (PAR) Control Authority, Industry Industrial Data Summary Form (IDSF) Town Name => City of Newton Name SpecialMetals Use separate forms for each industry/pipe WWTP Name => Clark Creek W WTP iUP # 1015 Enter BDL values as < (value) NPDES # => NC0036196 Pipe # 2 l st 6 months, dates => 1/l/2022 6/30/2022 2nd 6 months, dates => 7/l/2022 12/31/2022 Total # of samples => * Maximum (mg/1) => * or Maximum (lb/d) _> * or Average (mg/1) _> * or Average Loading (lb/d) => % violations,(chronic SNC is >= 66%) _> % TRC violations, (SNC is >= 33 %) => Total # of samples => * Maximum (mg/1) _> * or Maximum (lb/d) _> * or Average (mg/1) => * or Average Loading (lb/d) _> % violations, (chronic SNC is >= 66%) _> % TRC violations, (SNC is >= 33 %) _> Total # of samples => * Maximum (mg/1) _> * or Maximum (lb/d) => * or Average (mg/1) _> * or Average Loading (lb/d) _> % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) _> It w, m mm ni s mon s n mon s s mon s 2n(l(jmOnLhs IstOmonths 2nCLOMOntlis I st 0 monnis 2nc. 0 montlis 10 3 Not Required Not Required Not Required 0.004777 0.00387 Per Permit Per Permit Per Permit 0.0042774 0.0036 rSen rmumUOD smos m st m n months st o st mon n m Not Required Not Required 9 3 Not Required Per Permit Per Permit 0.038 0.0169 Per Permit 0.00135 0.00053 0.0203 0.0091 0.00072 0.00029 0% 0% 0% 0% opper yam a ea ercury st months n months st mon s n mon s st 6 months 2nd 0 months I st 6 months 2nd 6 months Not Required Not Required Not Required Not Required Per Permit Per Permit Per Permit Per Permit BDL=> Below Detection Limit mg/I => milligrams per liter * POTW must enter at least one of these [UP => Industrial User Permit Ib/d => pounds per day four rows, Please indicate how averages were calculated SNC => Significant Non -Compliance mgd => million gallons per day Avg period could be month, Qtr, or 6-month & if BDL , 1/213DL, or zero values used. TRC => Technical Review Criteria W WTP —> wastewater treatment plant Chapter: PAR Guidance Pile name: PlOiotiidfiih�sadedieialeQ3HhaQttg&L syet9BAB, pages 12, 13, 14 Blank IDSF Form, Copy and use in your PAR Number each set for each IUP pipe - Page of Pretreatment Annual Report (PAR) Industrial Data Summary Form (IDSF) Use separate forms for each industry/pipe Total # of samples => * Maximum (mg/1) _> * or Maximum (lb/d) => * or Average (mg/1) _> * or Average Loading (lb/d) _> % violations, (chronic SNC is >— 66%) _> % TRC violations, (SNC is >= 33 %) => Total # of samples => * Maximum => * or Minimum => % violations, (chronic SNC is >— 66%) _> % TRC violations, (SNC is >— 33 %) _> Total # of samples => Maximum (mg/1) => or Maximum (lb/d) => or Average (mg/1) _> or Average Loading (lb/d) => % violations, (chronic SNC is >= 66%) _> % TRC violations, (SNC is >= 33 %) _> Industry Name Special Metals IUP # 1015 Pipe # 2 t nmm Silver r m s mon s n mon s s mon s n mon s s mon s n rut s s mon s TnCI b mon s 9 3 2 Annual Not Required Not Required 0.33 0.183 0.005 Monitoring Per Permit Per Permit 0.01174 0.00577 0.00017 Only 0.1797 0.122 0.005 0.00636 0.00377 0.00017 0% 0% 0% 0% 0% 0% pH I empera ure I'luoricle st mont s 2nd6months Ist6months 2nd6months Ist6months 2nd6months st 6 months 2nd 6 months 10 3 10 3 4 3 8.7 8.5 33 40 0.05 0.1 7.1 7.2 19 25 0.05 0.05 N/A st mont s 2nd6monLhs Ist6months 2nd6months I st 6 months 2nd 6 months I st 6 months 2nd 6 months BDL => Below Detection Limit mg/I => milligrams per liter * PO'I'W must enter at [cast one ofthese IUP => Industrial User Permit Ib/d => pounds per day four rows, Please indicate how averages were calculated SNC => Significant Non -Compliance mgd => million gallons per day Avg period could be month. Qtr. or 6-month & if BDL I/2BDL or zero values used TRC —> Technical Review Criteria W WTP => wastewater treatment plant Chapter: PAR Guidance File name: P/@orfldfilh�sih*esGeiu�daRhaQlmiAJ:etRBAB, pages 12, I3, 14 Blank IDSF Form, Copy and use in your PAR Number each set for each IUP pipe - Page of Pretreatment Annual Report (PAR) Industrial Data Summary Form (IDSF) Use separate forms for each industry/pipe Enter BDL values as < (value) Total # of samples => * Maximum (mg/1) _> * or Maximum (lb/d) _> * or Average (mg/1) _> * or Average Loading (lb/d) _> % violations,(chronic SNC is >- 66%) _> % TRC violations, (SNC is >= 33 %) _> Total # of samples => * Maximum (mg/1) _> * or Maximum (lb/d) _> * or Average (mg/1) _> * or Average Loading (Ib/d) _> %violations, (chronic SNC is>= 66%) _> % TRC violations, (SNC is >= 33 %) _> Total # of samples => * Maximum (mg/1) -> * or Maximum (lb/d) _> * or Average (mg/1) _> * or Average Loading (lb/d) _> % violations, (chronic SNC is >- 66%) _> % TRC violations, (SNC is >= 33 %) _> Control Authority, Town Name => City of Newton WWTP Name => Clark Creek NPDES # _> 1st 6 months, dates => 1/l/2022 to 6/30/2022 2nd 6 months, dates -> 7/l/2022 to 12/31/2022 Industry Name Wanzl IUP # 1018 Pipe # 1 I IF K, m nr Lst b Months 2nct 0 months Ist 0 months Zncl MonMs' ist o months 2771 o months tSt 0 months 2nd 6 months 8 2 2 2 0.0509 133.8 148.0 6.9 56.7989 62.82689 2.92909 0.03639 99.5 95.5 6.85 36.20252 36.55964 2.27717 N/A N/A 0% 0% 0% N/A N/A 0% 0% 0% rsenic Uaclanum Uhromium st mont s n mon s 777mon s 777mon= s st mont s 2nd 6 months Not Required 7 7 2 Per Permit 0.001 0.2 274 0.00024 0.03636 116.3146 0.00046 0.05533 220 0.00013 0.0132 78.02404 0% 0% )% 0% 0% 0% opper Uyamde Leacl Iviercury st 6 months 2nd 6 months I st 6 months 2nd 6 months I st 0 months 2nd 6 months Ist 6 months 12nd 6 months 7 7 7 Not Required 0.049 0.01 0.0125 Per Permit 0.01467 0.0028 0.00494 0.04106 0.005 0.00366 0.01155 0.0014 0.0012 0% 0% 0% 0% 0% 0% BDL => Below Detection Limit mg/1 => milligrams per liter * POTW must enter at least one of these IUP => Industrial User Permit Ib/d=> pounds per day four rows, Please indicate how averages were calculated SNC => Significant Non -Compliance mgd => million gallons per day Avg period could be month, Qtr, or 6-month & if BDL , I/2131)1., or zero values used. TRC => Technical Review Criteria W WTP => wastewater treatment plant Chapter: PAR Guidance Pile name: PttCaxtl�SYihaixRcdieuuk{IS[JraQirnt&tciRRAB, pages 12, 13, 14 Blank IDSF Form, Copy and use in your PAR Number each set for each IUP pipe - Page of Pretreatment Annual Report (PAR) Industrial Data Summary Form (IDSF) Use separate forms for each industry/pipe Total # of samples => * Maximum (mg/1) _> * or Maximum (lb/d) _> * or Average (mg/1) => * or Average Loading (lb/d) => % violations, (chronic SNC is >— 66%) _> % TRC violations, (SNC is >= 33 %) _> Total # of samples => * Maximum => * or Minimum => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => Total # of samples => * Maximum (mg/1) => * or Maximum (lb/d) _> * or Average (mg/1) _> * or Average Loading (lb/d) => % violations, (chronic SNC is >= 66%) _> TRC violations, (SNC is >= 33 %) _> Industry Name Wanzl (Tech.) luP # 1018 Pipe # 1 tSelenium t v r to s mon s n mon s s mon s n mon s s Mon s n mon s s mon s 2rici6momnTrsm 7 1 Annual 7 7 0.062 0.005 Monitoring 0.005 0.096 0.02214 0.0012 Only 0.00198 0.03199 0.03561 0.005 0.0022 0.05993 0.0101 0.0012 0.00068 0.0173 0% 0% 0% 0% 0% 0% 0% 0% PH lemperature st mon[ s n mont s st mon s n mon s st mon s n months st mon s n mon s 8 8 9.4 29.8 8.6 12.3 N/A N/A N/A N/A N/A N/A N/A N/A UOrI e Ist6months 2n 6months 6months Ist6months Ist6months nd6months 1 Annual --�2ndtimonths 0.82 Monitoring *Certifies for TTO 0.19627 Only Not being present* 0.82 0.19627 0% 0a BUL => Below Detection Lunit mg/1 => milligrams per liter • PO IV must enter at least one of these IUP => Industrial User Permit Ib/d => pounds per day four rows, Please indicate how averages were calculated SNC => Significant Non -Compliance mgd => million gallons per day Avg period could be month, Qtr, or 6-month & if BDL 1/2BDL, or zero values used. TRC => Technical Review Criteria W WTP => wastewater treatment plant Chapter: PAR Guidance File time PF4hxlidfrlh�xidedi'aiarcd�liha¢tu,5r$I slticti7Bt4B, pages 12, 13, 14 Blank IDSF Form, Copy and use in your PAR Number each set for each IUP pipe - Page of Compliance Judgment Worksheet For SNC With Limits Use separate sheets for each Industry SNC determination for Flow optional, see Section 7-E Use separate sheets for each Pollutant SIU Name: Special Metals IUP Number: 1015 1 Pipe Number: 002 Parameter: Chromium Six Month SNC Determination Period: 1/l/22-6/30/22 Daily Limit Compliance Daily Max Limits IUP Limit * TRC criteria = TRC Limit Circle which units apply from IUP Circle 1.4 For TRC for BOD, TSS, oil, fat, grease; Circle 1.2 for all other pollutants to Limits TRC compliance judgment not required for pH: Daily Maximum Limit: 0.011573 * 1.2 or 1.4 = TRC Daily Limit: 0.0138876 mg/I or MM Column 1: 1- Industry self P-POTW Column 6: Use only if IUP has daily limits in lbs/day. Formula to use is ( mgd * mg/1 * 8.34 = Ibs/day ). Column 8: Put "1" for each daily maximum value, tally up at bottom as "A." Column 9: Compare daily values to IUP limits above,put "0" if at or below limit, "V if above, tally at bottom as'B." Column 10: Compare daily values to TRC limits above,put "0" if below limit, "I" if at or above, tally at bottom as "C." *Changed Special Metals Limits in May 2022* *June Updated Cr Limit to: 0.004676* Col. 1: From IDMRs From IDMRs From IDMRs Col. 5: Col 6: Col 7: Col 8: Col 9: Col 10: Sample Type Sample Date Daily Flow, mgd Daily Cone. mg/l Daily Load Ibs/day Count Regular Violation ? TRC Violation ? 1 115122 0.00478 0.0083 0.00033 1 0 0 1 116122 0.00422 0.0110 0.00039 2 0 0 1 1119122 0.00420 0.0380 0.00133 3 0 0 1 1120122 0.00427 0.0380 0.00135 4 0 0 1 1119122 0.00420 0.0230 0.00080 5 0 0 1 1120122 0.00427 0.0220 0.00078 6 0 0 P 1126122 0.00404 0.021 0.00071 7 0 0 P 2117122 0.004186 0.009 0.0054 8 0 0 1 416122 0.004578 0.0120 0.00046 9 0 0 List these Totals on next page => A = 9 B = 0 C= 0 Title: SNC With Limits Compliance Judgment Worksheet File name: Compliance Judgement 2022 Jan -Jun Cr Revision date: 1/5/01 Compliance Judgment Worksheet For SNC With Limits Use separate sheets for each Industry SNC determination for Flow optional, see Section 7-E Use separate sheets for each Pollutant SFLI Name: Special Metals FLIP Number: 1015 1 Pipe Number: 002 Parameter: Chromium Six Month SNC Determination Period: 1/1/22-6/30/22 Average Limit Compliance Monthly Avg. Limits IUP Limit * TRC criteria = TRC Limit Circle which units apply from IUP Circle 1.4 For TRC for BOD, TSS, oil, fat, grease; Circle 1.2 for all other pollutants to Limits TRC compliance judgment not required for pH: Monthly Avg. Limit: 0.004676 * LL or 1.4 = TRC Avg. Limit: 0.0056112 mg/1 or Ibs/day Column 1: 1 - Industry self P-POTW Column 5: Use only if IUP has (monthly, or other) average limit. Average values of all sampling events collected wtihin the "average" period (for example, for a monthly average limit, use all values collected within a calendar month) and enter this average in column 5. Treat this average as a count. Compare this average to the appropriate average IUP limit or TRC limit. Column 7: Use only if IUP has average limits in lbs/day. Use ( mgd * mg/l * 8.34 = Ibs/day ). Column 8: Put "1" for each average value, tally up at bottom as "D." Column 9: Compare average values to IUP limits above,put "0" if at or below limit, "1" if above, tally at bottom as 'E." Column 10: Compare average values to TRC limits above,put "0" if below limit, "1" if at or above, tally at bottom as "F." Col. 1: From IDMRs From IDMRs From IDMRs Col. 5: Col6: Col 7: Col 8: Col 9: Col 10: Sample Type Sample Date Avg Cone. mgh Avg. Load lbs/day Count Regular Violation TRC Violation 1 115122 0.00478 0.0083 0.00033 1 0 0 1 1/6122 0.00422 0.0110 0.00039 2 0 0 1 1119122 0.00420 0.0380 0.00133 3 0 0 1 1120122 0.00427 0.0380 0.00135 4 0 0 1 1119122 0.00420 0.0230 0.00080 5 0 0 1 1120122 0.00427 0.0220 0.00078 6 0 0 P 1126122 0.00404 0.021 0.00071 7 0 0 P 2117122 0.004186 0.009 0.00031 8 0 0 1 416122 0.004578 0.0120 0.00046 9 0 0 List these Totals on next page => D = 9 E = 0 F= 0 Title: SNC With Limits Compliance Judgment Workshcet Filename: Compliance Judgement 2022 Jan -Jun Cr Revision date: 1/5/01 Compliance Judgment Worksheet For SNC With Limits Use separate sheets for each Industry SNC determination for Flow optional, see Section 7-E Use separate sheets for each Pollutant SIU Name: Special Metals IUP Number: 1015 1 Pipe Number: 002 Parameter: Chromium Six Month SNC Determination Period: 1/l/22-6/30/22 SIGNIFICANT NON-COMPLIANCE (SNC) LIMITS DETERMINATION Calculate % and Circle Answers 1) Daily: Calculate the % of Regular violations: 0/9 2) Is B/A greater than or equal to 0.66 (or 66 %) ? 3) Average: Calculate the % of Regular violations: 4) Is E/D greater than or equal to 0.66 (or 66 %) ? 5) Daily: Calculate the % of TRC Violations: 0/9 6) Is C/A greater than or equal to 0.33 (or 33 %) ? 6) Average: Calculate the % of TRC Violations: 7) Is F/D greater than or equal to 0.33 (or 33 %) ? B/A = 0.00 Daily Chronic violator? Yes / E/D = Average Chronic violator? Yes / No C/A = 0.00 Daily TRC Violator? Yes / F/D = Average TRC Violator? Yes / No 8) Did any violation, alone or in combination with other discharges, cause pass -through or interference at the POTW, or endanger the health of POTW workers or the public? Yes / 9) Did any violation cause imminent endangerment to human health / welfare or to the environment or has resulted in the POTW's exercise of its emergency authority to halt or prevent such discharge? Yes / 10) If the answer to any of these questions is yes, the SIU is in Signficant Non -Compliance (SNC) for this parameter. They must be listed on the Significant Non -Compliance Report (SNCR) form in the Pretreatment Annual Report (PAR), described in the PAR narrative (including parameter, period, and POTW actions), and the POTW must take adequate enforcement as outlined in its Enforcement Response Plan (ERP). Is the SIU in SNC for this six month period? CIRCLE ONE: YES RU Was the SIU in SNC for THE SAME PARAMETER in the previous six month compliance period? CIRCLE ONE: YES 1\p If YES to EITHER question, DESCRIBE IN NARRATIVE. Please note if SIU was in SNC for the previous six month compliance period and is also in SNC for this six month compliance period, escalated enforcement actions must be taken as soon as possible, preferably before the end of the second consecutive period. Failure to take the action within 2 months after the end of the second consecutive period will subject the POTW to enforcement by the Division. The options are: Consent Order with Enforceable schedule; Administrative Order with Enforceable schedule; Formal notice to comply issued, or Permit modification. See Chapter 9 - Pretreatment Annual Reports, Chapter 8 - Enforcement, and the POTW's Enforcement Response Plan (ERP). Definitions: Count The number of daily sample data values or the number of average sampling events used for checking compliance with average limits. TRC Technical Review Criteria, Multiply the actual IUP limits by the proper TRC Criteria value to get a TRC Limit: TRC Criteria = 1.4 for BOD, TSS, oil, fat, grease TRC Criteria = 1.2 for all other pollutants Not required to perform TRC compliance judgment for pH. SNCR Significant Non -Compliance Report SNC Significant Non -Compliance Title: SNC With Limits Compliance Judgment Worksheet File name: Compliance Judgement 2022 Jan -Jun Cr Revision date: 1/5101 Compliance Judgment Worksheet For SNC With Limits Use separate sheets for each Industry SNC detennination for Flow optional see Section 7-E Use separate sheets for each Pollutant SIU Name: Special Metals IUP Number: 1015 1 Pipe Number: 002 Parameter: Nickel Six Month SNC Determination Period: 1/1/22-6/30/22 Daily Limit Compliance Daily Max Limits IUP Limit * TRC criteria = TRC Limit Circle which units apply from IUP Circle 1.4 For TRC for BOD, TSS, oil, fat, grease; Circle 1.2 for all other pollutants to Limits TRC compliance judgment not required for pH: Daily Maximum Limit: 0.017184 * or IA = TRC Daily Limit: 0.0206208 mg/1 or lbs/day June Daily Max Limit: 6011 773 * or 1.4 = TRC Daily Limit: 0.0138876 mg/I or lbs/day Column I: 1- Industry self P-POTW Column 6: Use only if ]UP has daily limits in lbs/day. Formula to use is ( mgd * mg/l * 8.34 = lbs/day ). Column 8: Put "1" for each daily maximum value, tally up at bottom as "A." Column 9: Compare daily values to IUP limits above,put "0" if at or below limit, "I" if above, tally at bottom as "B." Column 10: Compare daily values to TRC limits above,put "0" if below limit, "I" if at or above, tally at bottom as "C." *Changed Special Metals Limits in May 2022* *June Updated Ni Limit to: 0.011573* Col. 1: From IDMRs From IDMRs From IDMRs Col. 5: Col 6: Col7: Col 8: Col 9: Col 10: Sample Type Sample Date Daily Flow, mgd Daily Cone. mg/I Daily Load lbs/day Count Regular Violation ? TRC Violation ? 1 115122 0.00478 0.0280 0.00112 1 0 0 1 J16122 0.00422 0.0560 0.00197 2 0 0 1 1119122 0.00420 0.1800 0.00630 3 0 0 1 1120122 0.00427 0.3300 0.01174 4 0 0 1 1119122 0.00420 0.2100 0.00735 5 0 0 1 1120122 0.00427 0.2400 0.00854 6 0 0 P 1126122 0.00404 0.2480 0.00836 7 0 0 P 2117122 0.004186 0.1550 0.00541 8 0 0 1 416122 0.004578 0.1700 0.00649 9 0 0 List these Totals on next page => I A -9 I3 = 0 C= 0 Title: SNC With Limits Compliance Judgment Worksheet File name: Compliance Judgement 2022 Jan -Jun Ni Revision date: 1/5/01 Compliance Judgment Worksheet For SNC With Limits Use separate sheets for each Industry SNC determination for Flow optional, see Section 7-E Use separate sheets for each Pollutant SIU Name: Special Metals IUP Number: 1015 1 Pipe Number: 002 Parameter: Nickel Six Month SNC Determination Period: 1/l/22-6/30/22 Average Limit Compliance Monthly Avg. Limits IUP Limit * TRC criteria = TRC Limit Circle which units apply from IUP Circle 1.4 For TRC for BOD, TSS, oil, fat, grease; Circle 1.2 for all other pollutants to Limits TRC compliance judgment not required for pH: Monthly Avg. Limit: 0.011573 * 11 or 1.4 = TRC Avg. Limit: 0.0138876 mg/l or HWY, Column 1: 1- Industry self P-POTW Column 5: Use only iflUP has (monthly, or other) average limit. Average values of all sampling events collected wtthin the "average" period (for example, for a monthly average limit, use all values collected within a calendar month) and enter this average in column 5. Treat this average as a count. Compare this average to the appropriate average IUP limit or TRC limit. Column 7: Use only if IUP has average limits in Ibs/day. Use ( mgd * mg/I * 8.34 = Ibs/day ). Column 8: Put "V for each average value, tally up at bottom as "D." Column 9: Compare average values to IUP limits above,put "0" if at or below limit, "1" if above, tally at bottom as 'E." Column 10: Compare average values to TRC limits above,put "0" if below limit, "1" if at or above, tally at bottom as "F." *Did not issue a NOV for violation on 1/20/22, because the current permit does not have a monthly average. Had a meeting with state, waiting on approval as of 3/30/22. *May 18, 2022 moved monthly avg. to daily max on Pipe 02 to use the most stringent value* Col. 1: From IDMRs From IDMRs From IDMRs Col. 5: Col 6: Col 7: Col 8: Col 9: Col 10: Sample Type Sample Date Avg Cone. mg/l Avg. Load Ibs/day Count Regular Violation v TRC Violation 1 115122 0.00478 0.0280 0.00112 1 0 0 1 116122 0.00422 0.0560 0.00197 2 0 0 1 1119122 0.00420 0.1800 0.00630 3 0 0 1 1120122 0.00427 0.3300 0.01174 4 1, 0 1 1119122 0.00420 0.2100 0.00735 5 0 0 1 1120122 0.00427 0.2400 0.00854 6 0 0 P 1126122 0.00404 0.2480 0.00836 7 0 0 P 2117122 0.004186 0.1550 0.00541 8 0 0 1 416122 0.004578 0.1700 0.00649 9 0 0 List these Totals on next page => D = 9 E = 1 F= 0 Title: SNC With Limits Compliance Judgment Worksheet File name: Compliance Judgement 2022 Jan -Jun Ni Revision date: 1/5/01 Compliance Judgment Worksheet For SNC With Limits Use separate sheets for each Industry SNC determination for Flow optional, see Section 7-E Use separate sheets for each Pollutant SIU Name: Special Metals IUP Number: 1015 Pipe Number: 002 Parameter: Nickel Six Month SNC Determination Period: 1/l/22-6/30/22 SIGNIFICANT NON-COMPLIANCE (SNC) LIMITS DETERMINATION Calculate %and Circle Answers 1) Daily: Calculate the % of Regular violations: 1/9 B/A = 0.11 2) Is B/A greater than or equal to 0.66 (or 66 %) ? Daily Chronic violator? Yes / 3) Average: Calculate the % of Regular violations: 4) Is E/Dgreater than or equal to 0.66 (or 66 a/u) ? 5) Daily: Calculate the % of TRC Violations: 0/9 6) Is C/A greater than or equal to 0.33 (or 33 %) ? 6) Average: Calculate the % of TRC Violations: 7) Is F/D greater than or equal to 0.33 (or 33 %) ? E/D = Average Chronic violator? Yes / No C/A = 0.00 Daily TRC Violator? Yes / F/D = Average TRC Violator? Yes / No 8) Did any violation, alone or in combination with other discharges, cause pass -through or interference at the POTW, or endanger the health of POTW workers or the public? Yes / 9) Did any violation cause imminent endangerment to human health / welfare or to the environment or has resulted in the POTW's exercise of its emergency authority to halt or prevent such discharge? Yes /Ib 10) If the answer to any of these questions is} as, the SIU is in Signficant Non -Compliance (SNC) for this parameter. They must be listed on the Significant Non -Compliance Report (SNCR) form in the Pretreatment Annual Report (PAR), described in the PAR narrative (including parameter, period, and POTW actions), and the POTW must take adequate enforcement as outlined in its Enforcement Responce Plan (ERP). Is the SIU in SNC for this six month period? CIRCLE ONE: YES NO Was the SIU in SNC for THE SAME PARAMETER in the previous six month compliance period? CIRCLE ONE: YES NO If YES to EITHER question, DESCRIBE IN NARRATIVE. Please note if SIU was in SNC for the previous six month compliance period and is also in SNC for this six month compliance period, escalated enforcement actions must be taken as soon as possible, preferably before the end of the second consecutive period. Failure to take the action within 2 months after the end of the second consecutive period will subject the POTW to enforcement by the Division. The options are: Consent Order with Enforceable schedule; Administrative Order with Enforceable schedule; Formal notice to comply issued, or Permit modification. See Chapter 9 - Pretreatment Annual Reports, Chapter 8 - Enforcement, and the POTW's Enforcement Response Plan (ERP). Definitions: Count The number of daily sample data values or the number of average sampling events used for checking compliance with average limits. TRC Technical Review Criteria, Multiply the actual IUP limits by the proper TRC Criteria value to get a TRC Limit: TRC Criteria = 1.4 for BOD, TSS, oil, fat, grease TRC Criteria — 1.2 for all other pollutants Not required to perform TRC compliance judgment for pH. SNCR Significant Non -Compliance Report SNC Significant Non -Compliance Title: SNC With Limits Compliance Judgment Worksheet File name: Compliance Judgement 2022 Jan -Jun Ni Revision date: 1/5/01 Compliance Judgment Worksheet For SNC With Limits Use separate sheets for each Industry SNC determination for Flow optional, see Section 7-E Use separate sheets for each Pollutant SIU Name: Special Metals IUP Number: 1015 1 Pipe Number: 002 Parameter: Chromium Six Month SNC Determination Period:7/l/22-12/31/22 Daily Limit Compliance Daily Max Limits IUP Limit * TRC criteria = TRC Limit Circle which units apply from IUP Circle 1.4 For TRC for BOD, TSS, oil, fat, grease; Circle 1.2 for all other pollutants to Limits TRC compliance judgment not required for pH: Daily Maximum Limit: 0.004676 * 1.2 or 1.4 = TRC Daily Limit: 0.0056112 mg/1 or lbs/day Column L I - Industry self P-POTW Column 6: Use only if IUP has daily limits in lbsiday. Formula to use is ( mgd * mg/I * 8.34 = lbs/day ). Column 8: Put "V for each daily maximum value, tally up at bottom as "A." Column 9: Compare daily values to IUP limits above,put "0" if at or below limit, "1" if above, tally at bottom as "B." Column 10: Compare daily values to TRC limits above,put "0" if below limit, "1" if at or above, tally at bottom as "C." Col. 1: From IDMRs From IDMRs From IDMRs Col. 5: Col 6: Col7: Col 8: Col 9: Col 10: Sample Type Sample Date Daily Flow, mgd Daily Cone. mg/1 Daily Load lbs/day Count Regular Violation ? TRC Violation ? 1 716122 0.00316 <0.005 0.00007 1 0 0 P 7127122 0.00387 0.0080 0.00026 2 0 0 1 1016122 0,00378 0.0169 0.00053 3 0 0 List these Totals on next page => A = 3 B = 0 C= 0 Title: SNC With Limits Compliance Judgment Worksheet File name: Compliance Judgement 2022 Jul -Dec Cr Revision date: 1/5/01 Compliance Judgment Worksheet For SNC With Limits Use separate sheets for each Industry SNC determination for Flow optional, see Section 7-E Use separate sheets for each Pollutant SIU Name: Special Metals IUP Number: 1015 1 Pipe Number: 002 Parameter: Chromium Six Month SNC Determination Period:7/l/22-12/31/22 SIGNIFICANT NON-COMPLIANCE (SNC) LIMITS DETERMINATION Calculate % and Circle Answers 1) Daily: Calculate the % of Regular violations: 0/3 B/A = 0.00 2) Is B/A greater than or equal to 0.66 (or 66 %) ? Daily Chronic violator? Yes /$ 3) Average: Calculate the % of Regular violations: E/D = 4) Is E/D greater than or equal to 0.66 (or 66 °/a) ? Average Chronic violator? Yes / No 5) Daily: Calculate the % of TRC Violations: 0/3 C/A = 0.00 6) Is C/A greater than or equal to 0.33 (or 33 %) ? Daily TRC Violator? Yes / 6) Average: Calculate the % of TRC Violations: F/D = 7) Is F/D greater than or equal to 0.33 (or 33 %) ? Average TRC Violator? Yes / No 8) Did any violation, alone or in combination with other discharges, cause pass -through or interference at the POTW, or endanger the health of POTW workers or the public? Yes / 9) Did any violation cause imminent endangerment to human health / welfare or to the environment or has resulted in the POTW's exercise of its emergency authority to halt or prevent such discharge? Yes /Po 10) If the answer to aM of these questions is .es, the SIU is in Signficant Non -Compliance (SNC) for this parameter. They must be listed on the Significant Non -Compliance Report (SNCR) form in the Pretreatment Annual Report (PAR), described in the PAR narrative (including parameter, period, and POTW actions), and the POTW must take adequate enforcement as outlined in its Enforcement Responce Plan (ERP). Is the SIU in SNC for this six month period? CIRCLE ONE: YES NO Was the SIU in SNC for THE SAME PARAMETER in the previous six month compliance period? CIRCLE ONE: YES Q; If YES to EITHER question, DESCRIBE IN NARRATIVE. Please note if SIU was in SNC for the previous six month compliance period and is also in SNC for this six month compliance period, escalated enforcement actions must be taken as soon as possible, preferably before the end of the second consecutive period. Failure to take the action within 2 months after the end of the second consecutive period will subject the POTW to enforcement by the Division. The options are: Consent Order with Enforceable schedule; Administrative Order with Enforceable schedule; Formal notice to comply issued, or Permit modification. See Chapter 9 - Pretreatment Annual Reports, Chapter 8 - Enforcement, and the POTW's Enforcement Response Plan (ERP). Definitions: Count The number of daily sample data values or the number of average sampling events used for checking compliance with average limits. TRC Technical Review Criteria, Multiply the actual IUP limits by the proper TRC Criteria value to get a TRC Limit: TRC Criteria = 1.4 for BOD, TSS, oil, fat, grease TRC Criteria = 1.2 for all other pollutants Not required to perform TRC compliance judgment for pH. SNCR Significant Non -Compliance Report SNC Significant Non -Compliance Title: SNC With Limits Compliance Judgment Worksheet File name: Compliance Judgement 2022 Jul -Dec Cr Revision date: 1/5/01 Compliance Judgment Worksheet For SNC With Limits Use separate sheets for each Industry SNC determination for Flow optional, see Section 7-E Use separate sheets for each Pollutant SIU Name: Special Metals IUP Number: 1015 1 Pipe Number: 002 ::::] Parameter: Nickel Six Month SNC Determination Period: 7/l/22-12/31/22 Daily Limit Compliance Daily Max Limits IUP Limit * TRC criteria = TRC Limit Circle which units apply from IUP Circle 1.4 For TRC for BOD, TSS, oil, fat, grease; Circle 1.2 for all other pollutants to Limits TRC compliance judgment not required for pH: Daily Maximum Limit: 0.011573 * M or 1.4 = TRC Daily Limit: 0.0138876 mg/I or Ibs/day Column 1: I - Industry self P-POTW Column 6: Use only if IUP has daily limits in Ibs/day. Formula to use is ( mgd * mg/I * 8.34 = Ibs/day ). Column 8: Put "1" for each daily maximum value, tally up at bottom as "A." Column 9: Compare daily values to IUP limits above,put "0" if at or below limit, "I" if above, tally at bottom as "B." Column 10: Compare daily values to TRC limits above,put "0" if below limit, ' V if at or above, tally at bottom as "C." Col. 1: From IDMRs From IDMRs From IDMRs Col. 5: Cal 6: Col 7: Col 8: Col 9: Col 10: Sample Type Sample Date Daily Flow, mgd Daily Conc. mg/I Daily Load Ibs/day Count Regular Violation ? TRC Violation ? 1 716122 0.00316 0.0640 0.00169 1 0 0 P 7127122 0.00387 0.1190 0.00384 2 0 0 1 1016122 0.00378 0.1830 0.00577 3 0 0 List these Totals on next page => A = 3 13 = 077 T-077 Title: SNC With Limits Compliance Judgment Worksheet File name: Compliance Judgement 2022 Jul -Dec Ni Revision date: 1/5/01 Compliance Judgment Worksheet For SNC With Limits Use separate sheets for each Industry SNC determination for Flow optional, see Section 7-E Use separate sheets for each Pollutant SIU Name: Special Metals [UP Number: 1015 1 Pipe Number: 002 ::::] Parameter: Nickel Six Month SNC Determination Period: 7/l/22-12/31/22 SIGNIFICANT NON-COMPLIANCE (SNC) LIMITS DETERMINATION Calculate % and Circle Answers 1) Daily: Calculate the % of Regular violations: 0/3 B/A = 0.00 2) Is B/A greater than or equal to 0.66 (or 66 %) ? Daily Chronic violator? Yes / 3) Average: Calculate the % of Regular violations: 4) Is E/D greater than or equal to 0.66 (or 66 %) ? 5) Daily: Calculate the % of TRC Violations: 0/3 6) Is C/A greater than or equal to 0.33 (or 33 %) ? 6) Average: Calculate the % of TRC Violations: 7) Is F/D greater than or equal to 0.33 (or 33 %) ? E/D = Average Chronic violator? C/A = 0.00 Daily TRC Violator? F/D = Average TRC Violator? 8) Did any violation, alone or in combination with other discharges, cause pass -through or interference at the POTW, or endanger the health of POTW workers or the public? 9) Did any violation cause imminent endangerment to human health / welfare or to the environment or has resulted in the POTW's exercise of its emergency authority to halt or prevent such discharge? Yes / No �W Yes / No Yes / No 10) If the answer to aM of these questions is Ms, the SIU is in Signficant Non -Compliance (SNC) for this parameter. They must be listed on the Significant Non -Compliance Report (SNCR) form in the Pretreatment Annual Report (PAR), described in the PAR narrative (including parameter, period, and POTW actions), and the POTW must take adequate enforcement as outlined in its Enforcement Responce Plan (ERP). Is the SIU in SNC for this six month period? CIRCLE ONE: YES NO Was the SIU in SNC for THE SAME PARAMETER in the previous six month compliance period? CIRCLE ONE: YES If YES to EITHER question, DESCRIBE IN NARRATIVE. Please note if SIU was in SNC for the previous six month compliance period and is also in SNC for this six month compliance period, escalated enforcement actions must be taken as soon as possible, preferably before the end of the second consecutive period. Failure to take the action within 2 months after the end of the second consecutive period will subject the POTW to enforcement by the Division. The options are: Consent Order with Enforceable schedule; Administrative Order with Enforceable schedule; Formal notice to comply issued, or Permit modification. See Chapter 9 - Pretreatment Annual Reports, Chapter 8 - Enforcement, and the POTW's Enforcement Response Plan (ERP). Definitions: Count The number of daily sample data values or the number of average sampling events used for checking compliance with average limits. TRC Technical Review Criteria, Multiply the actual IUP limits by the proper TRC Criteria value to get a TRC Limit: TRC Criteria = 1.4 for BOD, TSS, oil, fat, grease TRC Criteria = 1.2 for all other pollutants Not required to perform TRC compliance judgment for pH. SNCR Significant Non -Compliance Report SNC Significant Non -Compliance Title: SNC With Limits Compliance Judgment Worksheet File name: Compliance Judgement 2022 Jul -Dec Ni Revision date: 1/5/01 Allocation Table Headworks last approved: 01/19/18 Allocation Table updated: 06/28/22 Permits last modified: 05/19/22 City of Newton HWA Design 2022 Spreadsheet Instructions: 1) Applicable Values should be entered in the Heavy Bordered cells. Rest of worksheet is protected, password is ,.2.. 2) Formulas are discussed in the Comprehensive Guidance, Chapter 6, Section C. 3) HWA and AT worksheets in this workbook are linked. Pollutant Names, MAHLs, Basis, and Uncontrollable load in this AT worksheet are automatically entered from the HWA spreadsheet. This includes pollutant names in columns AT through BK. IUP Count 1 INDUSTRY NAMES (view rar aienaxrdy) Engineered Controls industry Permit number 101J Pipe number Ol Type of Indus 433 Renewal Effective Date 5/l2018 Modification Effective Date Date Permit Expires 4/30/2023 Permit Limits Permit Limits Permit Limits MGD al/da Cone. Load m lbs/da Cone. Load m lbs/da 0.0050 5,000 2 1 lickory Springs IOIILS Ol 433 11/142017 11i132022 0.0030 3,000 3 Special Metals pipe 01 1015 Ol 471 721/202o 5/182022 7/31/2025 0.0285 28,500 29.00 55.00 4 Special Metals pipe 02 1015 02 471 72 t2o2o 5/182022 7/31/2025 5 WamJ 1018 01 433 7et2azo 5/19/2022 7r312o25 0.0702 70,200 94.00 64.00 6 7 8 Column Totals => Basis=> 0.1067 NPuica 106,700 123 ne_yinn 1 19 n>,nn MAID. from FIWA. Ib( )_-=> NPDES Permitted Flmr—> Uncontrollable Loading (Ibs/day) => Total Allowable for Industry (MAIL) (Ibs/day) _> Total Permitted to Industry (lbs/day) => Percent Allow. Ind. (MAIL) still available (%) => 5 Percent MAHL(lbs/da)=> 5.0000 18765 15596 2.7701 6977 10304 2.2299 11788 5292 0.1067 2.1232 123 119 1.1665, 5173 95.2 % 99.0 % 97.8 % z °r 0.2500 938 7SO Page 1 of 4 City of Newton HWA Design 2022 Allocation Table Headworks last approved: 01/19/18 Allocation Table updated: 06/28/22 Permits last modified: 05/19/22 Sludge Sludge Basis > Design Ceiling Stream Std Stream Std Ceiling Stream Sid __ MAHI, from FiWA. 1(bs/day) —> _ 799.81 0.5829 0.2795 3.9742 _ _ 16.0883 _ 0.9015 Uncontrollable Loading (lbs/day) _> 679.22 0.0693 0.0231 0.4828 2.6083 0.0693 Total Allowable for Industry (MAIL) (lbs/day) => 120.59 1 0.51351111 0.2564 3.4914 13.4800 0.8322 0.0000 Percent Allow. Ind. (MAIL) still available (%) => I S7.1 % I I l ou %j 1 86.2 % 1 1 74.9 % 1 925 % F 7-5.4 5 Percent MAIM (lbs/dav) —> Page 2 of 4 City of Newton HWA Design 2022 Allocation Table Headworks last approved: 01/19/18 Allocation Table updated: 06/2&22 Permits last modified:1 05/19/22 Sludge Sludge 13asis=> Stream Std Stream Std Ceiling Ceiling Stream Std Stream Std MMK_. _ _MAHL from _HWA 1(,bs/da.Y)=> _._. Uncontrollable Loading (lbs/day) _> Total Allowable for Industry (MAIL) (lbs/day) => Total Permitted to Industry (lbs/dav) => still available (%)=> 1 87.4%1 1 loc)'Y%j 1 100.0%1 1 67.2%1 1 loo,vy.j 1 11TI% 5 Percent MAIL (lbs/dav) => Page 3 of 4 City of Newton HWA Design 2022 Allocation Table Headworks last approved: 01/19/18 Allocation Table updatetl: 06/28/22 Permits last modifed: 05/19/22 Sludge Basis=> MAHL from HWA lb�� _> _ Uncontrollable Loading (lbs/day) => Total Allowable for Industry (MAIL) (lbs/day) => Total Permitted to Industry Obs/dav) => Stream Std _. Portent Allow. Ind. (MAII.),Lill available (%)=> 9).9% i:VA1,UI;1RVALUB' 9R2% vVA1,Ul', eittMAHL still. avaiialile (%1=> 61.9% , .#VALUE!I #VALUB!902% 1 #VAT ITP Page 4 of 4 June 8, 2022 McKenna Belvins Pretreatment Coordinator Clark Creek W WTP Post Office Box 550 Newton, NC 28658 Dear Ms. Belvins: Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit limitation for total toxic organics (TTO), I certify that, to the best of my knowledge, no dumping of concentrated toxic organics into the wastewaters has occurred since filing of the last monitoring report. I further certify that this facility is implementing the toxic organic management plan submitted to the City of Newton. Please feel free to contact us if further information is required. Sincerely, Blake Guffey EHS Coordinator Technibilt, Ltd. / Wanzl, NA Wanzl. I PO Box 310 1 700 Technibilt Drive I Newton, NC 28658 1 www.Wanzl.com Wanzi Certified: 7014 2120 0002 5646 8165 December 6, 2022 McKenna Blevins Pretreatment Coordinator Clark Creek WWTP PO Box 550 Newton, NC 28658 RE: Total Toxic Organics Dear Ms. Blevins: Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit limitation for total toxic organics (TTO), I certify that, to the best of my knowledge, no dumping of concentrated toxic organics into the wastewaters has occurred since filing of the last monitoring report. I further certify that this facility is implementing the toxic organic management plan submitted to the City of Newton. Please feel free to contact us if further information is required. Sincerely, ro� 6t2�) Kelli Daniels EHS Manager Wanzl, NA Wanzl NA. PO Box 310 1700 Technibilt Drive I Newton, NC 28658 1 www.technibiltcom /1► N ]{�wrl'C)N BR11114,11 EEG4G7- BBIGBI IUIURI P.O. Box 550* Newton, N.C. 28658*(828) 695-4300 Pretreatment Annual Report City of Newton MIMA I certify, under penalty of law, that the information contained in this report is, to the best of my knowledge and belief, true, accurate, and complete. James Wentz; Director of Public Works Date 02/13/2023 McKenna Blevins; Pretreatment Coord WA Date c? 13 o?a�3