HomeMy WebLinkAboutH&C Farm Application Replacement p 2 and 32.3 Acreage cleared and available for application (excluding all required buffers and areas not covered by the application
system): See attached Waste Utilization Plan Acres
Required Acreage (as listed in the CAWMP): See attached Waste Utilization Plan Acres
Existing Application Area (pre -construction): See attached Waste Utilization Plan Acres
Proposed Application Area (post -construction): See attached Waste Utilization Plan Acres
Is there a change to the existing WUP? YES or NO (circle one)
Is the Existing WUP attached? YES or NO (circle one)
Is the New (if applicable) WUP attached? YES or NO (circle one)
Note: The New WUP is pending by the grower
2.4 List and Describe all Storage/Treatment Structures Below:
a. DIGESTER or other PRIMARY TREATMENT: (double click on "Select" for drop -down menu box)
Treatment
Unit Type
YP
Existing?
(YIN)
Name of
Treatment
Unit
Type of
Liner
Material
Surface
Area
Type of Cover
Material
Ttl Capacity
(cu. Ft.)
Req'd
Capacity
(cu.ft.)
Digester
N
Digester
Synthetic
39,200
Synthetic (80 mil)
248,943
226,800
Select
Select
Synthetic (80 mil)
Select
Select
Select
a.1 Are engineering designs, drawings, specifications, and details attached?
YES or NO (circle one)
b. SECONDARY TREATMENT/STORAGE: (double click on "Select" for drop -down menu box)
Name of Storage
Unit
Existing?
(UN)Material
Type of Liner
Surface Area
Ttl Capacity
(cu. Ft.)
Req'd Capacity
(cu.ft.)
Lagoon 1
1'
Soil in situ
171,000
1,407,360
1,382,558
Select
Select
Select
*Note: The "Total Capacity" and "Req'd Capacity" are provided based on the lagoon design for the existing lagoon on
this farm, designed by Don butler (dated 1993-1-11)
2.5 Are KNOWN subsurface drains present within 100' of any application fields?
YES
2.6 Are KNOWN subsurface drains in the vicinity or under the waste management system? YES
2.7 Does this facility meet all applicable siting requirements? YES
or NO (circle one)
or NO (circle one)
or NO (circle one)
2.8 Describe Water Movement between Barns, Digesters, and Storage Ponds (double click on "Select" for drop -down menu
box)
Location
Pump Station or
Gravity
Pipe Size
Minimum Pump
Capacity
Plan Sheet
Reference
GPM
TDH
Barns to Digester
Influent Pump Station
8"
515
24
C.2.8.1
Digester to Secondary
Gravity
12"
C.2.8.1
Select
Select
FORM: AWO-STATE-G-DIGESTER-7/07/2022
Page 2 of 6
Select
Select
Select
Select
3. REQUIRED ITEMS CHECKLIST:
Please indicate that you have included the following required items by signing your initials in the space provided next to each
item.
3.1 One completed and signed original of the application for Digester Animal Waste Management
System Application Form.
3.2 A general location map indicating the location of the animal waste facilities and field locations
where animal waste is land applied and a county road map with the location of the facility
indicated.
3.3 Documentation that new digester structure(s) meets the Swine Farm Siting Act, for swine
operations.
3.3.1 Site Map. The scale of this map shall not exceed 1 inch = 400 feet.
3.3.2 All proposed digesters to occupied residences > 1500 feet OR no closer than existing setback.
Existing setback = > 1500 feet
3.3.3 All proposed digesters to schools, hospitals, churches, outdoor recreational facilities, national parks, state
parks, historic properties, or childcare centers > 2500 feet OR no closer than existing setback.
Existing setback = > 2500 feet
3.3.4 All proposed digesters to property boundaries > 500 feet OR no closer than existing setback.
Existing setback = > 500 feet
3.3.5 All proposed digesters to Public Water supply wells > 500 feet.
3.3.6 The map shall show the location of any property boundaries and perennial streams, or rivers located A
ng, but not limited to, calculations,
ings to scale, construction materials,
within 75 feet of waste application areas.
3.4 One copy of all engineering documents, includi
equipment specifications, plan and profile draw
supporting equations or justifications.
3.5 A detailed narrative of the Farm Digester Animal Waste Management System.
3.6 A copy of the CAWMP which must include the following components. Some of these
components may not have been required at the time the facility was initially certified but must
be added to the CAWMP for permitting purposes:
3.6.1 The Waste Utilization Plan (WUP) must include the amount of Plant Available Nitrogen (PAN)
produced and utilized by the facility
3.6.2 The method by which waste is applied to the disposal fields (e.g., irrigation, injection, etc.)
3.6.3 A map of every field used for land application
3.6.4 The soil series present on every land application field
3.6.5 The crops grown on every land application field
3.6.6 The Realistic Yield Expectation (RYE) for every crop shown in the WUP
3.6.7 The PAN applied to every application field
3.6.8 The waste application windows for every crop utilized in the WUP
3.6.9 The required NRCS Standard Specifications
3.6.10 A site schematic
3.6.11 Emergency Action Plan
3.6.12 Insect Control Checklist with chosen best management practices noted
3.6.13 Odor Control Checklist with chosen best management practices noted
3.6.14 Mortality Control Checklist with the selected method noted
FORM: AWO-STATE-G-DIGESTER-7/07/2022 Page 3 of 6