HomeMy WebLinkAboutNC0035149_Permit (Correction)_20230207DocuSign Envelope ID: 8E412CDE-21 D0-4864-8419-0469F5E6896B
ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
RICHARD E. ROGERS, JR.
Director
Water Resources Management, Inc.
ATTN: Randy Carter
151 Mr. Bish Blvd
Boone, NC 28607
Dear Permittee:
NORTH CAROLINA
Environmental Quality
2/7/2023
Subject: Change -Page to Correct Error
NPDES Permit NC0035149
Water Resources Management, Inc.
Seven Devils Resort WWTP
Watauga County
The Division of Water Resources (the Division) became aware of an error in your recently issued permit (January
30, 2023) for Seven Devils Resort WWTP, NPDES Permit No. NC0035149. It has been brought to our attention
that the Renewal needed clarification as follows:
• The sample location for Temperature has been changed to upstream & downstream in Section A. (2.)
Effluent Limitations and Monitoring Requirements.
• The sample location for Temperature has been changed to upstream & downstream in Section A. (3.)
Effluent Limitations and Monitoring Requirements.
Therefore, the Division has made a correction to the appropriate pages in the Permit Renewal. Please insert the
enclosed corrected pages into your existing permit and discard the old pages. We regret any inconvenience this
causes your organization.
Please note that this permit is not transferable except after notice to the Division. The Division may require
modification or revocation and reissuance of the permit. This permit does not affect the legal requirements to
obtain other permits which may be required by the Division of Water Resources or any other Federal, State, or
Local governmental permits that may be required.
If you have questions, or if we can be of further service, please contact Siying Chen at siying.chen@ncdenr.gov
or call (919) 707-3619.
Respectfully,
—DocuSigned by:
8328B44CE9EB4A1...
Richard E. Rogers, Jr.
Director, Division of Water Resources
Enclosure: NPDES Permit NC0035149 (Corrected Pages)
cc: NPDES Program Files [Laserfiche]
NC DEQ Winston-Salem Regional Office [email]
Carolina Water Service — Neil Reece [Ronnie.reece@carolinawaterservicenc.com]
1:tE
NORTH CAROLINA
Department of Environmental Wanly
North Carolina Department of Environmental Quality I Division of Water Resources
512 North Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617
919.707.9000
NPDES Permit NC0035149
A. (2.) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS
[15 NCAC 02B .0400 et seq., 02B .0500 et seq.]
Grade WW-2 Water Pollution Control System [15A NCAC 08G.0302]
Beginning on the effective date of this permit and lasting until expansion above 0.020 MGD or permit
expiration, the Permittee is authorized to discharge from Outfall 001. Such discharges shall be limited,
monitored, and reportedi by the Permittee as specified below:
PARAMETER
[Parameter Codes]
EFFLUENT LIMITATIONS
MONITORING
REQUIREMENTS
Monthly
Average
Daily
Maximum
Measurement
Frequency
Sample
Type
Sample
Location
Flow
50050
0.070 MGD
Continuous
Recorder
Effluent
Temperature
00010
Daily
Grab
Effluent
Total Residual Chlorine 2
50060
28 fag/L
2/Week
Grab
Effluent
Dissolved Oxygen
00300
Not < 6.0 mg/L
Weekly
Grab
Effluent
Total Suspended Solids
C0530
30.0 mg/L
45.0 mg/L
Weekly
Composite
Effluent
BOD 5-Day
C0310
30.0 mg/L
45.0 mg/L
Weekly
Composite
Effluent
pH
00400
Not < 6.0 or> 9.0 s. u.
Weekly
Grab
Effluent
Ammonia (NH3 as N)
[Apr 1 to Oct 31]
C0610
2.0 mg/L
10.0 mg/L
Weekly
Composite
Effluent
Ammonia (NH3 as N)
[Nov 1 to Mar 31]
C0610
4.6 mg/L
23.0 mg/L
Weekly
Composite
Effluent
Fecal Coliform
(geometric mean)
31616
200 / 100 mL
400 / 100 mL
Weekly
Grab
Effluent
Total Nitrogen
(NO2+NO3+TKN)
C0600
Quarterly
Composite
Effluent
Total Phosphorus
C0665
Quarterly
Composite
Effluent
Temperature
00100
Weekly
Grab
U & D 3
Dissolved Oxygen
00300
Weekly
Grab
Effluent
Turbidity
00070
Weekly
Grab
Effluent
Footnotes:
1. The Permittee shall submit discharge Monitoring Reports electronically using the Division's eDMR
submittal system [see A. (4.)].
2. The Division shall consider all effluent TRC values reported below 50 µg/L to be in compliance with
the permit. However, the Permittee shall continue to record and submit all values reported by a North
Carolina certified laboratory (including field certified), even if these values fall below 50 µg/L.
3. U = Upstream — 50 feet above the discharge; D = Downstream —100 feet below the discharge.
Conditions:
• All samples must be taken from a typical discharge event.
• There shall be no discharge of floating solids or foam in other than trace amounts.
Page 4 of 8
NPDES Permit NC0035149
A. (3.) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS
[15 NCAC 02B .0400 et seq., 02B .0500 et seq.]
Grade WW-2 Water Pollution Control System [15A NCAC 08G.0302]
Beginning on the effective date of this permit and lasting until expansion above 0.020 MGD or permit
expiration, the Permittee is authorized to discharge from Outfall 001. Such discharges shall be limited,
monitored, and reportedi by the Permittee as specified below:
PARAMETER
[Parameter Codes]
EFFLUENT LIMITATIONS
MONITORING
REQUIREMENTS
Monthly
Average
Daily
Maximum
Measurement
Frequency
Sample
Type
Sample
Location
Flow
50050
0.120 MGD
Continuous
Recorder
Effluent
Temperature
00010
Daily
Grab
Effluent
Total Residual Chlorine2
50060
28 pg/L
2/Week
Grab
Effluent
Dissolved Oxygen
00300
Not < 6.0 mg/L
Weekly
Grab
Effluent
Total Suspended Solids
C0530
30.0 mg/L
45.0 mg/L
Weekly
Composite
Effluent
BOD 5-Day
C0310
30.0 mg/L
45.0 mg/L
Weekly
Composite
Effluent
pH
00400
Not < 6.0 or > 9.0 s. u.
Weekly
Grab
Effluent
Ammonia (NH3 as N)
[Apr 1 to Oct 31]
C0610
2.0 mg/L
10.0 mg/L
Weekly
Composite
Effluent
Ammonia (NH3 as N)
[Nov 1 to Mar 31]
C0610
3.4 mg/L
17.0 mg/L
Weekly
Composite
Effluent
Fecal Coliform
(geometric mean)
31616
200 / 100 mL
400 / 100 mL
Weekly
Grab
Effluent
Total Nitrogen
(NO2+NO3+TKN)
C0600
Quarterly
Composite
Effluent
Total Phosphorus
C0665
Quarterly
Composite
Effluent
Temperature
00100
Weekly
Grab
U & D 3
Dissolved Oxygen
00300
Weekly
Grab
Effluent
Turbidity
00070
Weekly
Grab
Effluent
Footnotes:
1. The Permittee shall submit discharge Monitoring Reports electronically using the Division's eDMR
submittal system [see A. (4.)].
2. The Division shall consider all effluent TRC values reported below 50 µg/L to be in compliance with
the permit. However, the Permittee shall continue to record and submit all values reported by a North
Carolina certified laboratory (including field certified), even if these values fall below 50 µg/L.
3. U = Upstream — 50 feet above the discharge; D = Downstream —100 feet below the discharge.
Conditions:
• All samples must be taken from a typical discharge event.
• There shall be no discharge of floating solids or foam in other than trace amounts.
Page 5 of 8